Better Standards, Better Life 1 Gas Metrology Gas Metrology Gas Metrology Gas Metrology for Technology Innovation & for Technology Innovation & for Technology Innovation & for Technology Innovation & Sustainable Development Sustainable Development Sustainable Development Sustainable Development Jin Jin Jin Jin Seog Seog Seog Seog Kim Kim Kim Kim (KRISS) (KRISS) (KRISS) (KRISS) Chair of Gas Analysis WG Chair of Gas Analysis WG Chair of Gas Analysis WG Chair of Gas Analysis WG

Upload: others

Post on 06-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 1

Gas Metrology Gas Metrology Gas Metrology Gas Metrology for Technology Innovation & for Technology Innovation & for Technology Innovation & for Technology Innovation & Sustainable DevelopmentSustainable DevelopmentSustainable DevelopmentSustainable Development

JinJinJinJin SeogSeogSeogSeog KimKimKimKim (KRISS)(KRISS)(KRISS)(KRISS)Chair of Gas Analysis WGChair of Gas Analysis WGChair of Gas Analysis WGChair of Gas Analysis WG

Page 2: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life

Introduction of Gas Metrology

Example of Gas Metrology Application to High Technology for GHG Reduction

KRISS Capability on Gas Metrology

2

Page 3: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life

National Metrology Institutes (NMI)

• Highest authority in metrology

• Maintain the national measurement standards

- Directly traceable to primary standards when NMI realize

the SI units of measurement standards

- Should insure that the measurements are traceable to a primary

standards when NMI does not realize the SI units.

• Responsible for disseminating the national measurement

standard

• Mission: Increase Competitiveness of National Economy

and Quality of Life through Metrology

(Technology Innovation & Sustainable Development)

Page 4: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life

ROLE OF METROLOGY

Productivity

Product Quality

Product Defect Reduction

Impacts on Global Trade Issue

Increase Reliability on Legal Procedure

Over the last decade, there has been a significant increase in the recognition of

metrology and the important role it plays in improving

Page 5: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 5

SI

UNITS

Primary

Standard

Certified

Reference Material

Reference Gases

Working Standards, Samples

Measurement Hierarchy in Gas MetrologyMeasurement Hierarchy in Gas Metrology

mol/mol

National Metrology Institute (NMI)

Specialty Gas Company

Users

NMI/CRM producer

Page 6: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Gas Metrology

• Gas metrology for Industry and Quality of Life

- Produce Certified Reference Materials

- Improve Process Control, Quality Control

- Precise measurement of Emission,

Global warming, and Indoor air quality

• Gas Metrology for Science (as expert in measurement)

- Ar mole fraction in air: Air density

- Ne, Ar, He, C, N atomic weight (~ppm level accuracy)

- Triple point of gases, Boltzmann constant, Gas constant

Page 7: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Reference Material / National System

Primary Method

PRM

CRM

PTM

Key

Comp. Reg. CMC

Coding

Center

Testing Lab.

Regulation

Body

2nd RM

producers

(GLP, ISO/

IEC17025)RM, CRM

Page 8: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Roles of Gas Metrologist for Industry

CRM development

Environmental Effect : Global warming

Working Environmental Condition

Process Control for Quality

Testing services

Providing PT program

Education on Gas Analysis

Development of Analytical system :

simple & fast for quantification

Page 9: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Application Areas and Needs of CRMApplication Areas and Needs of CRMApplication Areas and Needs of CRMApplication Areas and Needs of CRM

Object Application FieldsNeeds of

CRM

Service to

industries

High Quality Products: Quality control

of manufacturing processΟ

Regulation for trade: RoHS, WEEE,

Safety RegulationΟ Ο Ο

New technology: R&D Ο

Regulations

Determine the limit for regulation:

Toxic chemical producers, Govnt Agency△△△△

Standards: Procedure, ISO/TC activity,

ValidationΟ

Testing report: QC, Traceability, Quantification Ο Ο Ο

Ability of Testing Lab: Participate in PT program Ο Ο

Page 10: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 10

Target Gas Chemicals for AnalysisTarget Gas Chemicals for AnalysisTarget Gas Chemicals for AnalysisTarget Gas Chemicals for Analysis

CFCs, PFCs : CF4, C2F6, SF6, NF3, Freon, Renewable refrigerants

Metal Hydrides : SiH4, PH3, AsH3, B2H6

Acids : F2, Cl2, HF, HCl, BF3, HBr, WF6

Odors : NH3, H2S etc.VOCs : BTX, Acetone, Alcohol, HCOHEnvironment: NO, CO, SO2, O3, Particles, GHGPure Gases : He, N2, H2, Ar, N2O, O2, AirGases in Liquid, Solid & BiomaterialsGases in Products (Lamps, Package, Vacuum,

Detectors, Display Pane ……)

Page 11: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 11

Procedure of Gas AnalysisProcedure of Gas AnalysisProcedure of Gas AnalysisProcedure of Gas Analysis

• Validated procedure• Calibration of Instrument & Apparatus• Confirm of Environmental Condition• Get Gas CRMs• Comparison of Samples and Gas CRMs• Evaluation of results• Report Concentration & its Uncertainty

Page 12: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 12

GC-TCD : inorganic gas

GC-FID : organic gas

GC-SCD : S containing gas mixture

GC-FID-Methanator : CO, CO2

GC-MSD : unknown gas identification

GC-ECD : F, Cl chemicals

GC-DID : ppb – ppm

GC-AED : Metallic gas, similar PRM

FTIR, NDIR, CRDS: impurities, CO2, CO, CH4, N2O

Dedicated analyzer: NOx, SO2, O3, H2O etc.

Gas MS : isolated samples, limited amount

IRMS : isotopic ratio

Instruments for Gas Analysis

Page 13: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 13

Procedure of Comparison MeasurementProcedure of Comparison MeasurementProcedure of Comparison MeasurementProcedure of Comparison Measurement

Making calibration line: Making calibration line: Making calibration line: Making calibration line: One point calibration: linear line through originOne point calibration: linear line through originOne point calibration: linear line through originOne point calibration: linear line through origin Two points Calib.: linear lineTwo points Calib.: linear lineTwo points Calib.: linear lineTwo points Calib.: linear line Multi points Calib.: nonMulti points Calib.: nonMulti points Calib.: nonMulti points Calib.: non----linear lineslinear lineslinear lineslinear lines

Use CRMs with most similar concentrationUse CRMs with most similar concentrationUse CRMs with most similar concentrationUse CRMs with most similar concentration If matrix is different, correct that effectIf matrix is different, correct that effectIf matrix is different, correct that effectIf matrix is different, correct that effect Check repeatability & reproducibilityCheck repeatability & reproducibilityCheck repeatability & reproducibilityCheck repeatability & reproducibility Correct drift effectCorrect drift effectCorrect drift effectCorrect drift effect Keep good baseline (purity of carrier gas)Keep good baseline (purity of carrier gas)Keep good baseline (purity of carrier gas)Keep good baseline (purity of carrier gas)

Page 14: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 14

Main Export Products during 1960s and 1970s

13.0

12.6

6.7

5.8

5.5

4.5

4.2

3.3

3.3

3.0

19601960

Iron Ore

Tungsten

Raw Silk Thread

Coal

Squid

Live Fish

Graphite

Wood Board

Rice

Bristle (hair)

Products %

11

22

33

44

55

66

77

88

99

1010

[1960s: Raw Materials] [1970s: Light industry goods]

Textiles

Wood Board

Wig (false hair)

Iron Ore

Electronics

Vegitables

Shoes

Lead & Lead Products

Steel Products

Metal Goods

40.8

11.0

10.8

5.9

3.5

2.3

2.1

1.6

1.5

1.5

Products %

11

22

33

44

55

66

77

88

99

1010

19701970

Economy of Republic of Korea : 50 year Ago

Page 15: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 15

[2000s: High Tech & Heavy Chemicals]

20002000

Semiconductor

Computer

Car

Petroleum Chemicals

Shipbuilding

Wireless Goods

Steel Plates

Clothes

Synthetic Textiles

Electronics

Products

11

22

33

44

55

66

77

88

99

1010

%

8.4

7.7

5.5

4.8

4.7

2.8

2.7

2.1

2.1

15.1

20062006

Semiconductor

Car

Wireless Goods

Shipbuilding

Petroleum Chemicals

Computer

Plat Panel Display

Synthetic Resins

Steel Plates

Automobile Parts

Products

11

22

33

44

55

66

77

88

99

1010

10.2

10.1

8.3

6.8

5.9

3.9

3.8

3.4

3.4

3.1

%

6.3

Main Export Products in Present

Economy of Republic of Korea : Recent

Page 16: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 16

Light Industries 1960-70

Heavy & Chemical Industries 1970-80

Electronics 1980-95

Information & Communication 1995-Present

Economic Growth of Korea

Page 17: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 17

○ DRAM: World market share 1st (45%)

○ Display Panel: World market share 1st (35%)

○ Shipbuilding: World market share 1st (40%)

○ Car: World market share 6th

○ Iron Plates: World market share 4 %

World Products from Korea

Page 18: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 18

▶ Monitor : From CRT to LCD/LED

▶ Large Screen TV : competition of LCD & PDP (> 50”)

▶ Mobile : LCD & OLED ( < 10” )

( VGA: 640 x 480, XGA: 1024 x 788, UXGA: 1600 x 1200, QXGA: 2048 x 1536)

10 15 20 30 40 50 100

VGA

XGA

Resolution

OLED

FED PDP

ProjectionCurrent LCD

Future LCD

Size(“)

Mobile

Display

Large TV

70

UXGA

(HDTV)

QXGA

Evolution of Display ScreenEvolution of Display ScreenEvolution of Display ScreenEvolution of Display Screen

Page 19: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 19

Development of OLED DisplayDevelopment of OLED DisplayDevelopment of OLED DisplayDevelopment of OLED Display

Large Screen OLED DisplayThin ~ 30 mm

amorphous-Si TFT– Large screen

poly-Si TFT– Long lifetime

Page 20: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 20

Oxidation

PR Coating

Coating

Etch

ImplantMetal Depo CMP

Photo Stepper

CVD

Ashing Wet

IngotSi Growth

Semiconductor Manufacturing ProcessSemiconductor Manufacturing ProcessSemiconductor Manufacturing ProcessSemiconductor Manufacturing Process

Sawing Wire Bond PKG IC Chip

Si Wafer

Page 21: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 21

Exhaust Gas Analysis for the Sustainable DevelopmentExhaust Gas Analysis for the Sustainable DevelopmentExhaust Gas Analysis for the Sustainable DevelopmentExhaust Gas Analysis for the Sustainable Development

VacuumPump

Process Tool POUScrubber

PFC TotalScrubber

Acid HouseScrubber

Abatement System Efficiency Analysis

Page 22: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 22

Efficiency of PFC Scrubber

ScrubberProcess

ChamberExhaust

In-let

Pin

Out-let

Pout

Qin Qout

)1()1()1( iiii dCFChFCofEmissio

FC

)1( iC )1( id

Ci = Qin ·Pin / FCin di = Qout ·Pout / Qin ·Pin

Qout = 1 / PHe

Page 23: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Emission Reduction Methodology for PFC & SF6

• Validated Procedures

Approved CDM Methodology by UNFCCC

Korean EPA modified UNFCCC methodology

• Reference Gas Mixtures (CRMs)

for calibration & validation

• UNFCCC: UN Framework Convention on Climate Change

Page 24: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Approved Methodology by UNFCCC

MethodologyApplying

CompanyReduction Mechanism

Monitoring

Instrument

AM0078

Display Process

in LG &

Samsung

SF6 Abatement by

fuel combustion

QMS, FTIR

Annubar

Water Analysis

AM0092

Semiconductor

in Chartered

Semi & Hynix

Substitution of C2F6

with c-C4F8

FTIR

QMS(Kr)

AM0096Semiconductor

in Samsung

CF4 Abatement by

electrical heaterQMS(He)

Page 25: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

AM0092

Schematic:

Baseline &

project

emission

QMS

FTIR

MFC

Kr

Cal. System

Page 26: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Quantification by QMS with Reference Standard Gas:

N2, O2, CO2, Ar, SF6, He, Kr, Xe

Quantification by FTIR with Reference Standard Gas:

CO2, CO, SF6, NO, SO2

Quantification by FTIR with Library Information:

HF, SiF4, SOF2, SO2F2, …

Difficult components: F2, Cl2 (memory effect in QMS)

Strategy of Quantification

Page 27: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

CCQM-K15 (2003)

Coordinating Lab: KRISS

Subatance: SF6 & CF4 hundred μmol/mol level

To support industry on PFC emission

Page 28: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

28Better Standards, Better Life

Primary Reference MaterialPrimary Reference MaterialPrimary Reference MaterialPrimary Reference Material---- Purity assessment Purity assessment Purity assessment Purity assessment

¦ MolecularMolecularMolecularMolecular weightsweightsweightsweights ofofofof sourcesourcesourcesource gasesgasesgasesgases (isotopic(isotopic(isotopic(isotopic ratio)ratio)ratio)ratio)¦ ImpurityImpurityImpurityImpurity analysisanalysisanalysisanalysis basedbasedbasedbased onononon finalfinalfinalfinal concentrationconcentrationconcentrationconcentration

---- Accurate mixing (Gravimetry)Accurate mixing (Gravimetry)Accurate mixing (Gravimetry)Accurate mixing (Gravimetry)---- Internal consistency by comparisonInternal consistency by comparisonInternal consistency by comparisonInternal consistency by comparison (4 cyl. at a time)(4 cyl. at a time)(4 cyl. at a time)(4 cyl. at a time)---- Stability test (2 cyl. after 6 months)Stability test (2 cyl. after 6 months)Stability test (2 cyl. after 6 months)Stability test (2 cyl. after 6 months)---- Verification through KC (including uncertainty)Verification through KC (including uncertainty)Verification through KC (including uncertainty)Verification through KC (including uncertainty)---- Register to BIPM CMCRegister to BIPM CMCRegister to BIPM CMCRegister to BIPM CMC (as NMI)(as NMI)(as NMI)(as NMI)---- Validation of life time by periodical reproductionValidation of life time by periodical reproductionValidation of life time by periodical reproductionValidation of life time by periodical reproduction---- Economically not good (managing by national body)Economically not good (managing by national body)Economically not good (managing by national body)Economically not good (managing by national body)

Page 29: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

29Better Standards, Better Life

“Maximum capacity 15 kg /

Readability 1 mg• Much easier, much faster, highly precise:

round type

• Pressure, temperature, relative humidity

recorded automatically

• Two or three cylinders measured

serially (e.g., A-B-A-B, A-B-C-A-B-C,

or A-C-A-C cylinders)

• Date, time, pressure, temperature,

relative humidity are all automatically

recorded by a customized program

developed at KRISS

A Recent Change in the Comparator Balance (2007)

Mettler Toledo AG (Model XP26003L)

Maximum capacity 26.1 kg / Readability 1 mg

※ Therefore, now we can measure the weights of cylinders having a

volumetric capacity of up to 10 L.

Fully Automated Weighing System (2006)Fully Automated Weighing System (2006)Fully Automated Weighing System (2006)Fully Automated Weighing System (2006)

NIST, NPL

NMISA,

ASTAR/NMC

NIM, LIPI

ITRI/NMC

Page 30: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

30Better Standards, Better Life

• CFC & PFC Gases : For semiconductor companiesCFCl3, CF2Cl2, CF3Cl, C2F3Cl3 ---- 110-2 mol/mol, 1-100 μmol/mol

NF3, C3F6, SF6, CF4, CHF4, C3F8 ---- 110-2 mol/mol, 1-100 μmol/mol

• Green House Gases :CO2 ---- 110-2 mol/mol, 380 μmol/mol

CH4 ---- 110-2 mol/mol, 1.8 μmol/mol

CO2+CH4+N2O ---- mixture at ambient level

CFCs, PFC, NF3, SF6--- ambient level

• Air Pollution Monitoring Gases :CO, NO, SO2, VOCs, Aldehydes, ( O3 Primary calibration system)

Developed CRMs in KRISSDeveloped CRMs in KRISSDeveloped CRMs in KRISSDeveloped CRMs in KRISS

Page 31: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Primary Reference Gas Mixture for

Green House Gases

substance Range of Certified Values Uncertainty (k=2) ref

CO2 above 10 μmol/mol 0.06 at 380 μmol/mol CCQM-K52, K120

CH4 above 100 nmol/mol 0.002 at 1.9 μmol/mol CCQM-K82

N2O above 50 nmol/mol 0.24 at 320 nmol/mol CCQM-K68

SF6

NF3

above 6 pmol/mol for SF6

above 1 nmol/mol for NF3 (0.5 pmol/mol after

2011)

0.06 at 6 pmol/mol for SF6

0.01 at 1 nmol/mol for NF3

CCQM-K15

PFCs

above 10 pmol/mol for CF4

above 100 μmol/mol for C2F6

(50 pmol/mol after 2011)

0.1 at 10 pmol/mol for CF4 CCQM-K15

HFCs above 30 pmol/mol for HFC23 0.15 at 50 omol/mol CCQM-K84

CFCs μmol/mol~50 pmol/mol for CFC 11,12,113 0.5 at 50 pmol/mol CCQM-K84

Page 32: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

32Better Standards, Better Life

Proficiency Test for Specialty Gas CompaniesProficiency Test for Specialty Gas CompaniesProficiency Test for Specialty Gas CompaniesProficiency Test for Specialty Gas Companies

---- PT provided by official bodyPT provided by official bodyPT provided by official bodyPT provided by official body---- Round Robin TestRound Robin TestRound Robin TestRound Robin Test---- 1:1 comparison (bilateral, trilateral)1:1 comparison (bilateral, trilateral)1:1 comparison (bilateral, trilateral)1:1 comparison (bilateral, trilateral)

A B C D E-5

-4

-3

-2

-1

0

1

2

3

4

5

CO2

Rela

tive D

evia

tio

n

Lab CodeLab CodeLab CodeLab Code

Page 33: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 33

Gas Analysis in IT industry by KRISSGas Analysis in IT industry by KRISSGas Analysis in IT industry by KRISSGas Analysis in IT industry by KRISS

Gas Analysis : Quality control of products, development of new Gas Analysis : Quality control of products, development of new Gas Analysis : Quality control of products, development of new Gas Analysis : Quality control of products, development of new product & problem solving in processproduct & problem solving in processproduct & problem solving in processproduct & problem solving in process

New Technology:

Backlight & PDP

Developing New product:

Organic Light Emitting Display

QC: Process Control

Reduction of GHGs:

Gas Scrubber

Page 34: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 34

융Abs. Isotope

Ratio, for ITS90

Industry

Support

ClimateChange/

Air Pollution

MetrologyKC

CRM

Social

Issue

(Fine Dust)

Researcher: 9

Engineer: 8

Technician: 3

Ph.D Std.: 4

Ms D Std: 9

Temp. member: 3

Human Resources of Center for Gas Analysis

Page 35: Gas Metrology for Technology Innovation & Sustainable ... · JinJJiinnJinSeog SeogSeogKim KKiimmKim(KRISS) (KRISS) Chair of Gas Analysis WG. Better Standards, Better Life Introduction

Better Standards, Better Life 35

Technology Innovation & Sustainable Development

by Gas Analysis Center