Page 1: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

Interface

ETHERNET

v.1.0

CODE: INTE EN*

Edition: 3 from 05.12.2013

Supercedes edition: 2 from 19.12.2012

Page 2: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

2

TABLE OF CONTENTS

1. General description. .................................................................................................................................. 3

2. Components arrangement........................................................................................................................ 3 3. Installation. ................................................................................................................................................. 4

4. Ethernet interface configuration............................................................................................................. 5 4.1 The factory settings of the interface........................................................................................................................................5 4.2 Introductory information. ........................................................................................................................................................5 4.3 STEP 1 - Restoring the factory settings..................................................................................................................................5 4.4 STEP 2 – The IP address configuration..................................................................................................................................6 4.5 STEP 3 – Setting the serial port parameters...........................................................................................................................7

5. PSU configuration ...................................................................................................................................11 5.1 Configuration of power supplies of PSBEN series with LCD display. ............................................................................. 11 5.2 Configuration of power supplies of PSBEN series with LED display .............................................................................. 12 5.3 Configuration of power supplies of EN54 series with LCD display ................................................................................. 13 5.4 Configuration of power supplies of EN54 series with LED display ................................................................................. 14

5.4.1 Setting the transmission speed....................................................................................................................................... 14 5.4.2 Setting the parity of the transmission............................................................................................................................. 15

6. Configuring the connection in PowerSecurity program. ..................................................................16

7. Technical parameters..............................................................................................................................17

Page 3: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

3

Features: connection to the ETHERNET network via the RJ45 connector compliance with the IEEE 802.3 standard 10/100BaseT physical layer transmission speed 10/100Mbps (auto-sensing) full-duplex or half-duplex operation (auto-sensing) built-in web server for configuration data encryption: DES, 3DES, AES assigning a static or dynamic IP address (DHCP server) galvanic isolation between the Ethernet interface and the power supply power supply via the „SERIAL” socket cooperation with PowerSecurity program optical indication warranty - 5 years from the production date

1. General description.

The ETHERNET network interface is a device used to connect power supplies of the PSBEN or EN54 series to a PC via the Ethernet connection. The PowerSecurity software enables remote monitoring of parameters through a cyclical preview of the current status of the power supply, reading the event log and diagrams of currents and voltages and performing remote battery test. 2. Components arrangement. The figure below shows the distribution of the major components and connectors of ETHERNET interface.

Fig.1. The interface view.

Table 1. Description of the components. Element nr Description

[1] LED lights – optical indication: PWR – supply voltage TX – transmitting data RX – receiving data

[2] RST button – resetting the interface settings [3] INIT button – initialization of the interface [4] RJ45 socket [5] SERIAL socket for connection with the power supply [6] Green LED light – signaling the operating status [7] Yellow LED light – Ethernet connection indication

Page 4: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

4

3. Installation. The Ethernet interface should be mounted inside the enclosure of the PSU. The connection

between the power supply with Ethernet interface and the router should be made with a twisted pair with RJ45 connectors. The role of the access point controlling the data flow is done by a router connected to a PC via Ethernet cable.

Fig.2. Schematic diagram of Ethernet network communication.

Interface installation:

1. Install the Ethernet interface in the enclosure of the PSU. 2. Connect the „SERIAL” sockets on the interface module and on the PCB of the power supply

using the included cable. 3. Plug the RJ45 connector of the twisted pair into the Ethernet interface. Plug the other end of the

twisted pair to the router "LAN" socket. 4. The router "LAN" socket should be connected to the network card of the computer using a RJ45 -

RJ45 cable.

Page 5: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

5

4. Ethernet interface configuration.

4.1 The factory settings of the interface.

Login page:

User name - root Password - dbps

IP address assigned automatically from the routers DHCP server

Network name (SSID) No name Network security No security settings Serial port communication parameters Not configured

4.2 Introductory information.

Ethernet interface parameters can be configured to adapt to the actual operation. Configuration is

done via a web browser after proper logging with username and password. The "Digi Device Discovery" program, which allows previewing the most important parameters of

the interface at the initial stage of configuration, is also worth noting. The application indicates the modules connected to the router and provides information about the assigned IP address and a unique MAC address. „Digi Device Discovery” is available on:

http://www.pulsar.pl/pl/pliki/digi_discovery.exe

A newly purchased Ethernet interface is supplied in basic configuration (factory settings) which is not adapted for correct operation of the system. Since the communication with the interface uses a network cable, there is a need for proper configuration of the router in order to establish a connection with the interface. The most convenient solution is to own a separate router or to restore the factory settings of already owned router (if possible). The information included in the following subsections show „step by step” how to configure the router and the Ethernet interface assuming that both devices are set to factory settings (settings after a reset). In this manual, the configuration of the Ethernet interfaces has been based on a ‘LinkSys WRT54GL router.

4.3 STEP 1 - Restoring the factory settings. Router:

In order to restore the factory settings of the router, check the device’s manual and perform the appropriate actions following the manufacturer's instructions. In most cases it is enough to find the reset button on the rear side of the enclosure and hold it for approximately 5 seconds. After releasing the reset button, wait about 1 minute for the correct initialization of the router. Initialization resets the router settings to their default values: Address: 192.168.1.1 User name: admin User password: admin Ethernet interface: In order to restore the factory settings of the interface, press and hold the INIT button, then press and release the RESET button one time. Still holding the INIT button, wait approximately 20 seconds for the optical indication of the interface: green led blinking three times [6 – Fig.1] and then 5 more times. Proper initialization resets the interface settings, among others, to: Address: assigned automatically from the router User name: root User password: dbps

Page 6: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

6

After restoring the factory settings of the router and the interface, the yellow LED of the interface is on and the green LED is blinking, indicating active connection. If not, disconnecting and reconnecting the power supply of the module might be necessary. If that does not help, restore the factory settings of the router and the interface once again.

4.4 STEP 2 – The IP address configuration. For proper IP address change, it is recommended to turn off the firewall of the antivirus program for the time of configuration process.

Run the „Digi Device Discovery” program, with icon. After launching, the program will display the Ethernet interface logged in to the router. Identification of the module can be done by comparing the MAC addresses.

Fig. 3. Window of the „Digi Device Discovery” program showing a logged-in Ethernet interface. The MAC address of the interface is located under the barcode of the DIGI module.

Fig. 4. The MAC address on the DIGI module.

In order to facilitate the further use of the devices in the network, change the IP address assignment from automatic to manual. To do that, press the right mouse button on the line with the selected interface and choose „Configure network settings” option.

Page 7: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

7

Fig. 5. The window of network settings.

In the settings window, select the „Manually configure network settings” option and change the IP

address of the interface in the unblocked area to 192.168.1.101. The subnet mask and the default gateway IP address should be left unchanged.

Before setting the network address, make sure it is not used by any device on the network.

Confirm the changes by pressing the „Save” button. The ” Digi Device Discovery” application will

display the message about the need to restart the interface, which should be confirmed by pressing "OK”. A reset progress window will be displayed.

From now on, the router will "see" our interface at the new address.

4.5 STEP 3 – Setting the serial port parameters.

After entering the above settings of the router and Ethernet interface, configure the communication channel between the Ethernet interface and the power supply to which the interface is connected. To do that, double-click on the line of the selected interface in the „Digi Device Discovery” program. The default web browser window will open. Log in correctly to configure the interface.

Page 8: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

8

Fig. 6. The login window of the Ethernet interface.

Type: Username: root Password: dbps

Confirm by pressing the „Login” button. The adjustment window will be displayed. Select the „Serial Ports” option from the „Configuration” menu on the left side of the window.

Fig. 7. The interface configuration panel.

Select the "Port 1" once the window is loaded.

Next, select „Custom” in the „Select Port Profile” field and confirm by pressing the „Apply” button.

Page 9: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

9

Fig. 8. The interface configuration panel – serial port parameters.

After reloading the page, select the „Basic Serial Settings” tab at the bottom.

and enter the same settings as in the picture below.

The power supplies of the EN54 series allow higher transmission speed, and therefore instead of 19.2k 8E1 it can be set to 115.2k 8E1. The changed values apply to all settings.

Page 10: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

10

Fig. 9. The communication parameters of the serial port.

Confirm by pressing the „Apply” button. Next, choose the „Advanced Serial Settings” bar in the lower part of the window and enter the settings in the „TCP Settings” section as shown below. Confirm by pressing the „Apply” button.

Fig. 10. The interface configuration panel – the TCP tab.

Reset the Ethernet interface again. To do that, press the „Reset” button on the module or simply

disconnect the power supply for a few seconds. After the reset, the connection between the interface and the router should be back after approximately 30 seconds.

Page 11: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

11

The connection between the Ethernet interface and the power supply requires checking whether the serial port communication parameters are the same.

5. PSU configuration

5.1 Configuration of power supplies of PSBEN series with LCD display. The PSU is fitted with LCD display, which enables setting the communication parameters of the serial port from the LCD panel. To enter the setup mode, press the „SET” button from the main screen. - use the „>” or „<” buttons to display the PSU menu - press the „SET” button - use the „>” or „<” buttons to display the Transmission menu (The Transmission menu is at the bottom of the screen) - press the „SET” button, the prompt will appear at the end of the line - use the „>” or „<” buttons to set the 19.2k 8E1 - confirm by pressing the "SET" button

Page 12: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

12

5.2 Configuration of power supplies of PSBEN series with LED display The PSU is fitted with LED display, which enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the „<,>” rightmost and leftmost buttons on the LED panel. Depending on the displayed information, the following parameters can be set: „Adr” – the device address, „trS” – transmission speed, „trP” – transmission parameters. – simultaneously press the „<,>” rightmost and leftmost buttons on the LED panel - The „Adr” parameter will be displayed - press the right arrow „>” - The „trS” parameter will be displayed - press „OK.” - The display will show one of the two parameters: „9.6” or „19.2” informing about the selected transmission speed - use the „<” or „>” buttons in order to set the transmission speed to 19200, displayed as „19.2” - confirm by pressing „OK.” - The „trS” parameter will be displayed again - press the right arrow „>” - press "OK" when „trP” is displayed - The display will show one of the three parameters: „8n2”, „8E1” or „8o1” - use the „<” or „>” buttons in order to set the „8E1” parameter - confirm by pressing „OK.” - Simultaneously press the „<,>” rightmost and leftmost buttons to complete the configuration procedure

Page 13: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

13

5.3 Configuration of power supplies of EN54 series with LCD display

The power supplies of the EN54 series allow higher transmission speed, and therefore instead of 19.2k 8E1 it can be set to 115.2k 8E1. The changed values apply to all settings

The PSU is fitted with LCD display, which enables setting the communication parameters of the serial port from the LCD panel. To enter the setup mode, press the „SET” button from the main screen.

- use the „>” or „<” buttons to display the PSU menu - press the „SET” button - use the „>” or „<” buttons to display the Transmission menu (The Transmission menu is at the bottom of the screen) - press the „SET” button, the prompt will appear at the end of the line - use the „>” or „<” buttons to set the 19.2k 8E1 - confirm by pressing the "SET" button

Page 14: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

14

5.4 Configuration of power supplies of EN54 series with LED display The PSU is fitted with LED display, which enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the „<,>” rightmost and leftmost buttons on the LED panel.

5.4.1 Setting the transmission speed

- simultaneously press the „<,>” rightmost and leftmost buttons - The „tSt” parameter will be displayed - use the „<” or „>” buttons in order to display the „trS” parameter - press „OK” - The information about the transmission speed will be displayed - use the „<” or „>” buttons in order to set the required transmission speed,

- 9.6k : - 115.2k (factory setting)

- confirm by pressing „OK”

- in order to return to the main menu, simultaneously press the „<,>” rightmost and leftmost buttons

Page 15: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

15

5.4.2 Setting the parity of the transmission - simultaneously press the „<,>” rightmost and leftmost buttons - The „tSt” parameter will be displayed - use the „<” or „>” buttons in order to display the „trP” parameter - press „OK” - The information about the parity of transmission will be displayed - use the „<” or „>” buttons in order to set the required communication mode

- 8N2 - 8E1 (factory setting) - 8O1

- confirm by pressing „OK” - in order to return to the main menu, simultaneously press the „<,>” rightmost and leftmost buttons

Page 16: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

16

6. Configuring the connection in PowerSecurity program. For further configuration, the PowerSecurity program is required. The program is available on:

http://www.pulsar.pl/pl/pliki/PowerSecurity.exe It is an executable file, which does not require installation.

1) Run the PowerSecurity.exe. 2) Choose the Power Supplies > New Power Supply option from the menu bar. The “Configuration

of connection” window, that allows configuring the settings, will be displayed.

Fig. 11. The connection configuration window.

PSU Description Name PSU’s name

The name that should be assigned individually to each PSU. Address 1;

Fixed address. Refresh period of the preview [ms]

100 ÷ 60 000ms; Refresh period of the parameters in the preview window.

CONNECTION Type Modbus RTU – TCP/IP

TCP Address 192.168.1.101

PSU network address. Each Ethernet interface in the network has a unique address.

TCP port 2101 Response time [ms] 100 ÷ 60 000ms;

The response time from the power supply interface. The interval between the transmissions [ms]

The minimal interval between transmissions.

The number of retransmissions

The number of retransmissions after which the program reports a connection error.

Page 17: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

17

3) Once the connection configuration is loaded, the window with a „preview” tab is displayed. Press

the icon in the in the upper left corner to connect with the PSU. As a result, the window will display current parameters of the PSU, automatically updated on the basis of a preset refresh cycle.

Fig. 12. Remote desktop windows of the power supplies: PSBEN (right) and EN54 (left).

7. Technical parameters.

Power supply 5V from the „SERIAL” socket of the PSU Current consumption max 180mA TTL transmission speed max 115200 bauds, parity checking LAN Transmission speed 10/100Mbps (auto-sensing) Indication (LED lights): Tx, Rx, PWR Operating conditions temperature -10 oC ÷ 40 oC

relative humidity 20%...90% Dimensions (LxWxH) 63 x 50.2 x 24 [mm] Net / gross weight 0,04kg / 0,09kg Storage temperature -20ºC...+60ºC

Page 18: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

18

Page 19: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

19

Page 20: Interface ETHERNET - v1.0... ·  INTE 5 4. Ethernet interface configuration. 4.1 The factory settings of the interface. Login page: User name - root

www.pulsar.pl INTE

20

Pulsar K.Bogusz Sp.j. Siedlec 150, 32-744 Łapczyca, Poland

Phone (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 E-mail: [email protected], [email protected] http:// www.pulsar.pl, www.zasilacze.pl

WEEE Label Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE

Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste.

WARRANTY 5 years from the production date.

WARRANTY IS VALID only upon presentation of the original invoice.