AM-Solution B.V. Hoogvlietsekerkweg 126a 3194 AM Hoogvliet Phone : +31 10 7371019 Email : [email protected] Web : www.am-solution.com Visit our website for the latest updates at www.usbhostadapter.com for the best performance and results Check your nearest dealer or distributor for the latest updates, products and documentaƟon WWW.USBHOSTADAPTER.COM ML2i & ML3 USB Host Adapter Serie INSTRUCTION MANUAL Version 1.0 English (EN)

Upload: phungmien

Post on 05-Apr-2018

220 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Instructional manual ML3 (EN) 1.1 - AM-Solution B.V.am-solution.com/image/data/Innovative/UHA/PDF/UHA ML3 IM.pdfHow to use Place the adapter in the programming slot of the ML2i or

AM-Solution B.V. Hoogvlietsekerkweg 126a 3194 AM Hoogvliet Phone  : +31 10 7371019 Email  : [email protected] Web  : www.am-solution.com 

Visit our website for the latest updates at www.usbhostadapter.com for the best performance and results  

Check your nearest dealer or distributor for the latest updates, products and documenta on 

WWW.USBHOSTADAPTER.COM 

ML2i & ML3 USB Host Adapter Serie INSTRUCTION MANUAL 

Version 1.0 English (EN) 

Page 2: Instructional manual ML3 (EN) 1.1 - AM-Solution B.V.am-solution.com/image/data/Innovative/UHA/PDF/UHA ML3 IM.pdfHow to use Place the adapter in the programming slot of the ML2i or

How to use Place the adapter in the programming slot of the ML2i or ML3 controller, but only when the unit is switched off. Connect a USB s ck to the adapter. The adapter will be operated using the display and keyboard of the ML2i or ML3 controller.  

Without USB‐s ck the ML2i or ML3 will give the message "NO USB" in the display. In this case, some addi onal op ons are s ll available. When a USB s ck is connected the ML2i or ML3 controller starts up with the message "PROG SOFT".  

Use the 'up' and 'down' keys to step through the menu or change the se ngs. Use the 'enter' key to confirm choic‐es. Use the 'code select' key to return to the menu.  

Prepara ons USB s ck On the USB s ck a directory "CARRIER" must be created. In this directory, the so ware and configura on files (*.M2X and *.ML3) can be placed. The retrieved data files (*.DCX) will be placed by the adapter into the sub‐directory "DOWNLOAD". The adapter itself creates this directory if this directory cannot be found.  

Menu op ons  

Loading so ware ("PROG SOFT") This is the first op on a er the ML2i or ML3 controller starts up.  

A er pressing the 'enter' key, a list of available so ware files will be displayed. If no valid so ware files are pre‐sent, the message "NO FILES" appears.  

Select the upload file using the 'up' and 'down' keys. Press 'enter' to confirm your choice, the upload will start. The display shows "PROG" / "SOFT" in the first segment and the progress percentage in the second segment. When uploading is finished the display shows "PROG DONE", or in case of a failure "PROG ERR". 

 

Se ng configura on ("SET CONF") With this op on the configura on can be set. The configura on is taken from the configura on files called CFxxxxxx.M2X (where xxxxxx is the date). At least one of these configura on files must be in the directory "CARRIER" on the USB s ck. If not, the message "NO FILES" appears on the display.  

A er pressing the 'enter' key, a choice can be made out of configura on files on the USB s ck. The most recent file is shown first. A er choosing a file, a selec on from the list of configura ons can be made. A er loading the configura on file the display shows the message "EEPRM DONE". 

 

 

The most important func ons of the adapter are: Loading so ware into the ML2i controller Retrieving data from the ML2i controller   Beside these func ons, the adapter has the following addi onal op ons: Se ng configura on Se ng container ID Se ng date and  me Tes ng outputs of the ML2i controller Tes ng the display 

Downloading data ("RETR DATA") With this op on the stored data from the ML2i or ML3 controller can be wri en to the USB s ck. The following op ons are available: Load All Load 90 Days Load 60 Days Load 30 Days Load Trip  

A er selec ng an op on the downloading starts. The display shows "RETR" / "DATA" in the first segment and the progress percentage in the second segment. When the data retrieval is complete, the display shows "RETR DONE"; or in case of a failure "RETR ERR". If there is no valid data present in the ML2i or ML3 controller the dis‐play shows "NO DATA".

Se ng container ID ("SET ID") With this op on the container ID can be set. The ID will be displayed from right to le . The most right character in the display can be changed with the 'up' and 'down' keys. Because this character on the display has a few extra segments, all le ers will be properly displayed here. Some le ers will be legible worse when scrolling fur‐ther. Use the 'enter' key to confirm a character; use 'code select' to go back. The last digit (checksum) is auto‐ma cally calculated. On comple on the display shows "ID DONE".  

Se ng date and me ("SET TIME") With this op on the date and  me can be set. Successively year, month, day, hours and minutes can be set. On comple on the display shows "TIME DONE". 

Tes ng outputs ("SET OUTPT") With this op on the 14 relay outputs of the ML2i or ML3 controller can be manually energized. The relay will be energized as long as the 'enter' key is pressed. 

 

Tes ng display With this op on the display can be tested. When the 'return / supply' key is pressed all segments of the display and all LED’s will go off, when the '°C/°F' key is pressed all segments and LED’s will go on. This works as long as the key is pressed. A er releasing the keys, the normal display data will be displayed again.  

OPTIONAL Serialnumber corrup on fix, ERR1 ("PROG SN")  This feature is only available for the ML3 controller and only when the official Carrier Transicold file (ML3_serial_number_xxxx.bin) is placed in the “CARRIER” directory. A er pressing the 'enter' key, you are able to fix the serialnumber, but only when corrupted. Please follow the manufactures guide lines/instruc ons.  

OPTIONAL Upda ng USB adapter firmware ("PROG UHA")  When a so ware error is discovered or a new feature is added, we need to update the so ware of the adapter. This will be announced on the website (www.usbhostadapter.com).  Via this website, you download the  latest file (xxx.bin) and drop this on the USB s ck in the “CARRIER” directory. The UHA will automa cally recognize this file and ac vate the “PROG UHA” menu func on. A er pressing the 'enter' key, the so ware will be loaded into the UHA. A er the comple on of the update of the firmware, the USB adapter will reset itself. A display message "PROG SOFT" indicates the adapter is ready for use again.  

Read adapter firmware By pressing the 'alt. mode' key, the internal firmware version of the USB adapter will be displayed.  

Problems A display message "USB ERR" indicates adapter cannot read the USB s ck. Possibly the USB s ck is faulty or of a wrong type. The adapter does not support FAT12 file system (only used at USB s cks with a size of 32MB or less).  

A display message "CHIP ERR" indicates that the adapter itself does not func on properly. Possibly this can be put right by switching the power off and on again; otherwise the adapter may be defec ve.  

Visit our website for the latest updates at www.usbhostadapter.com for the best performance and results