installation instructions and owner's manual · home, where not prohibited by local codes....

52
UNVENTED GAS FIREPLACE MODELS VFP20IN3(0,1,2,3)L10(N,P)-1 VFP20IN73L10(N,P)-1 VFP20IN2(0,1,2,3)L(N,P)-1 VFP20IN3(0,1,2,3)L(N,P)-1 VFP20IN73L(N,P)-1 VFP28IN2(0,1,2,3)L(N,P)-1 VFP28IN3(0,1,2,3)L(N,P)-1 VFP28IN73L(N,P)-1 GAS-FIRED Vent Free Fireplace Insert INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL WARNING If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness. This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ven- tilation air must be provided. Refer to page 13. WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Refer to page 13. This appliance may be installed in an aftermar- ket, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Upload: others

Post on 10-Sep-2019

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

UNVENTED GAS FIREPLACE MODELSVFP20IN3(0,1,2,3)L10(N,P)-1

VFP20IN73L10(N,P)-1VFP20IN2(0,1,2,3)L(N,P)-1VFP20IN3(0,1,2,3)L(N,P)-1

VFP20IN73L(N,P)-1VFP28IN2(0,1,2,3)L(N,P)-1VFP28IN3(0,1,2,3)L(N,P)-1

VFP28IN73L(N,P)-1

GAS-FIRED

Vent Free Fireplace Insert

INSTALLATION INSTRUCTIONSAND OWNER'S MANUAL

WARNINGIf not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ven-tilation air must be provided. Refer to page 13.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERSWater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Refer to page 13.

This appliance may be installed in an aftermar-ket, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

WARNINGIf the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, per-sonal injury or loss of life.

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch; do

not use any phone in your building.• Leave the building immediately.• Immediately call your gas supplier

from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Page 2: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 2

SECTION PAGE

IMPORTANT SAFETY INFORMATION .............................................................................................................................................. 3SAFETY INFORMATION FOR USERS OF LP-GAS ......................................................................................................................... 4IMPORTANT INSTALLATION GUIDELINES ...................................................................................................................................... 5INTRODUCTION ................................................................................................................................................................................ 6SPECIFICATIONS .............................................................................................................................................................................. 7INSTALLATION IN A FIREPLACE ...................................................................................................................................................... 8FIREPLACE INSERT DIMENSIONS .................................................................................................................................................. 9BUILT-IN FIREPLACE INSTALLATION ............................................................................................................................................ 10VFP20IN FIREPLACE WITH SURROUND DIMENSIONS ...............................................................................................................11VFP28IN FIREPLACE WITH SURROUND DIMENSIONS .............................................................................................................. 12WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS .......................................................................................... 13PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR ..................................................................................... 13-14GAS SUPPLY ..............................................................................................................................................................................15-16CLEARANCES ............................................................................................................................................................................16-18COMBUSTIBLE MATERIALS ........................................................................................................................................................... 19ALTERNATE ON/OFF SWITCH INSTALLATION ........................................................................................................................ 20-21SURROUND PANEL INSTALLATION .............................................................................................................................................. 22BLOWER ACCESSORY INFORMATION ......................................................................................................................................... 23VFP20IN LOG PLACEMENT ........................................................................................................................................................... 24VFP20IN EMBER PLACEMENT PHOTOS ...................................................................................................................................... 25VFP28IN LOG PLACEMENT ........................................................................................................................................................... 26VFP28IN EMBER PLACEMENT PHOTOS ...................................................................................................................................... 27HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS .............................................................................................................. 28MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS ........................................................................................................... 2910,000 BTU MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS ....................................................................................... 30INTERMITTENT PILOT LIGHTING INSTRUCTIONS ...................................................................................................................... 31OPERATION INSTRUCTIONS/FLAME APPEARANCE .................................................................................................................. 32PILOT FLAME CHARACTERISTICS .......................................................................................................................................... 33-34WIRING ............................................................................................................................................................................................ 35MAINTENANCE ............................................................................................................................................................................... 35TROUBLESHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS ....................................................................... 36IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS ........................................................................................................... 37IPI ELECTRONIC SYSTEM WIRING DIAGRAM ............................................................................................................................. 38INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING ........................................................................................................ 39INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING ................................................................................................... 40-41VFP20IN PARTS LIST ...................................................................................................................................................................... 42VFP20IN PARTS VIEW .................................................................................................................................................................... 43VFP28IN PARTS LIST ...................................................................................................................................................................... 44VFP28IN PARTS VIEW .................................................................................................................................................................... 45LOGS PARTS LISTS & PARTS VIEWS ........................................................................................................................................... 46MASTER PARTS DISTRIBUTOR LIST ............................................................................................................................................ 47HOW TO ORDER REPAIR PARTS .................................................................................................................................................. 47DECORATIVE ACCESSORIES ........................................................................................................................................................ 48SURROUND FRONTS ................................................................................................................................................................ 49-50WARRANTY TERMS ........................................................................................................................................................................ 51

TABLE OF CONTENTS

Page 3: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 3

IMPORTANT SAFETY INFORMATIONDANGER: Indicates a hazardous situation which, if not avoided, will

result in death or serious injury.

WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Addresses practices not related to personal injury.• An unvented room heater having an input rating of more than

6,000 Btu per hour shall not be installed in a bathroom• An unvented room heater having an input rating of more than 10,000

Btu per hour shall not be installed in a bedroom or bathroom.• Due to high temperatures, the appliance should be located out of

traffic and away from furniture and draperies.• Children and adults should be alerted to the hazard of high surface

temperature and should stay away to avoid burns or clothing ignition.

• Young children should be carefully supervised when they are in the same room with the appliance.

• Do not place clothing or other flammable material on or near the appliance.

• Avoid the use of scented air fresheners (plug in type air fresheners, etc. ) while the log set is in operation. Air fresheners produce a residue in the air similar to candles and may produce a soot like substance.

• Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot like substance. Burning candles while the log set is operating magnifies the problem. It should be noted that candles, in general, produce soot. The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited.

• Installation and repair should be done by a QUALIFIED SERVICE PERSON. This appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

• DO NOT use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

• You must operate heater with fireplace screen in place. • Do not place trash, logs or other articles on the log set during

operation.• During manufacturing, fabricating and shipping, various

components of this appliance are treated with certain oils, films or bonding agents. These bonding agents are not harmful but may produce annoying smoke and smells as they are burned off during initial operation of the appliance. This is a normal temporary occurrence. A window should be opened during the initial bake out period.

• Correct installation of the ceramic fiber logs, proper location of the heater and annual cleaning are necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. See instructions for proper installation.

• WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

• WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

• WARNING! This fireplace needs fresh air for ventilation to run properly. This fireplace has an ODS (oxygen depletion sensor) which will shut down the heater if adequate fresh air is not available. See troubleshooting section in the instructions.

• WARNING: DO NOT operate this appliance unless all components including logs, burners, and controls are in good working condition. Never operate this appliance if any log or twig is broken, or out of their intended position. Refer to the Log set placement instructions for correct log and twig positioning. Replacement components are available through your local dealer as indicated in the How to Order Repair Parts section of the appliance manual.

• Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

• WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

WARNINGWhen used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poison-ous gas.

Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the writ-ten instructions provided with the heater for information concerning combustion and ventilation air. In the absence of instructions, refer to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation, or applicable local codes.

This heater is equipped with a PILOT LIGHT SAFETY SYS-TEM designed to turn off the heater if not enough fresh air is available.

DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!

If heater shuts off, do not relight until you provide fresh air.If heater keeps shutting off, have it serviced. Keep burner and control compartment clean.

CARBON MONOXIDE POISONING MAY LEAD TO DEATH.

Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced. Some people — pregnant women, persons with heart or lung disease, anemia, those under the influence of alcohol , those at high altitudes — are more affected by carbon monoxide than others.The pilot light safety system senses the depletion of oxygen at its location. If this heater is installed in a structure having a high vertical dimension, the possibility exists that the oxygen supply at the higher levels will be less than that at the heater. In this type of application, a fan to circulate the structure air will minimize this effect. The use of this fan will also improve the comfort level in the structure. When a fan is used to circulate air, it should be located so that the air flow is not directed at the burner.

Page 4: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 4

SAFETY INFORMATION FOR USERS OF LP-GASPropane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point with the members of your household. Someday when there may not be a minute to lose, everyone's safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.

LP-GAS WARNING ODORIf a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. That's your signal to go into immediate action!

• Donotoperateelectricswitches,lightmatches,useyourphone. Do not do anything that could ignite the gas.

• Geteveryoneoutofthebuilding,vehicle,trailer,orarea.Dothat IMMEDIATELY.

• Closeallgastankorcylindersupplyvalves.• LP-Gasisheavierthanairandmaysettleinlowareassuchas

basements.Whenyouhavereasontosuspectagasleak,keepoutofbasementsandotherlowareas.Stayoutuntilfirefightersdeclarethemtobesafe.

• Useyourneighbor'sphoneandcallatrainedLP-Gasserviceperson and the fire department. Even though youmay notcontinue to smell gas, do not turn on the gas again. Do not re-enterthebuilding,vehicle,trailer,orarea.

• Finally,lettheservicemanandfirefighterscheckforescapedgas.Havethemairouttheareabeforeyoureturn.Properlytrained LP-Gas service people should repair the leak, thencheckandrelightthegasapplianceforyou.

NO ODOR DETECTED - ODOR FADESome people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane.Smokingcandecreaseyourabilitytosmell.Beingaroundanodorforatimecanaffectyoursensitivityorabilitytodetectthatodor.Sometimesotherodorsintheareamaskthegasodor.Peoplemaynotsmellthegasodorortheirmindsareonsomethingelse.Thinkingaboutsmellingagasodorcanmakeiteasiertosmell.The odorant in LP-gas is colorless, and it can fade under some circumstances. Forexample,ifthereisanundergroundleak,themovementofthegasthroughsoilcanfiltertheodorant.OdorantsinLP-Gasalsoaresubjecttooxidation.Thisfadingcanoccurifthereisrustinsidethestoragetankorinirongaspipes.The odorant in escapedgas can adsorb or absorb onto or intowalls,masonryandothermaterialsandfabricsinaroom.Thatwilltakesomeoftheodorantoutofthegas,reducingitsodorintensity.LP-Gas may stratify in a closed area, and the odor intensity could varyatdifferentlevels.Sinceit isheavierthanair,theremaybemoreodoratlowerlevels.Alwaysbesensitivetotheslightestgasodor.Ifyoudetectanyodor,treatitasaseriousleak.Immediatelygo into action as instructed earlier.

SOME POINTS TO REMEMBER• Learn to recognize the odor of LP-gas. Your local LP-Gas

Dealer can give you a "Scratch and Sniff" pamphlet. Use it to findoutwhatthepropaneodorsmellslike.IfyoususpectthatyourLP-Gashasaweakorabnormalodor,callyourLP-GasDealer.

• Ifyouarenotqualified,donotlightpilotlights,performservice,ormakeadjustmentstoappliancesontheLP-Gassystem.Ifyouarequalified,consciouslythinkabouttheodorofLP-Gasprior to and while lighting pilot lights or performing service or makingadjustments.

• Sometimesabasementor a closed-uphousehasamustysmell that can cover up the LP-Gas odor. Do not try to light pilotlights,performservice,ormakeadjustmentsinanareawhere the conditions are such that you may not detect the odor iftherehasbeenaleakofLP-Gas.

• Odorfade,duetooxidationbyrustoradsorptiononwallsofnewcylindersandtanks,ispossible.Therefore,peopleshouldbeparticularlyalertandcarefulwhennewtanksorcylindersareplacedinservice.Odorfadecanoccurinnewtanks,orreinstalledoldtanks,iftheyarefilledandallowedtosettoolongbeforerefilling.Cylindersandtankswhichhavebeenoutof service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic snifftestofthegasisadvisable.If you have any question about the gas odor, call your LP-gas dealer. A periodic sniff test of the LP-gas is a good safety measure under any condition.

• If,atanytime,youdonotsmelltheLP-Gasodorantandyouthinkyoushould,assumeyouhavealeak.Thentakethesameimmediateactionrecommendedabovefortheoccasionwhenyou do detect the odorized LP-Gas.

• Ifyouexperienceacomplete"gasout,"(thecontainerisundernovaporpressure),turnthetankvalveoffimmediately.Ifthecontainer valve is left on, the container may draw in some air throughopeningssuchaspilotlightorifices.Ifthisoccurs,somenew internal rusting could occur. If the valve is left open, then treatthecontainerasanewtank.Alwaysbesureyourcon-tainerisundervaporpressurebyturningitoffatthecontainerbeforeitgoescompletelyemptyorhavingitrefilledbeforeitiscompletely empty.

Page 5: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 5

PROPER LOG PLACEMENTLogplacementiscriticaltoproperburnerperformance.Logsmustbecorrectlypositionedontotheburner.Thephotosinthismanualshow the proper pinned position for logs on this set. Owners need to beshownproperlogplacementandinstructednottomovethelogs.

Logsmustfitfirmlyontotheburnerwhenpositionedasshowninthephotos.Malformedlogsorlogswithsloppypinholesmustbereplaced.

PROPER PLACEMENT OF ROCK WOOL AND DECORATIVE LAVA ROCKRockwoolcanbeadded toburners foraglowingembereffect.Itmustbepositionedonlyonthefrontportionoftheburner.Thephotosinthismanualshowtheproperplacementofrockwool.Decorativelavarockorsmallwoodpiecesshouldneverbeplacedontheburner.Theseitemsareonlyforplacementonthefloorofthefireplaceorfirebox.PROPER PRIMARY AIRFLOW INTO BURNERFor proper burner operation and flame appearance, the flow ofprimaryairintotheventuritube,locatedontherearoftheburner,mustnotbereduced.Thisflowofairisreducedifdirt,lintorotherobstructionsbuild-uparoundorinsidetheventuri.Anyobstructionintheventuritubeareamustberemoved.Theflowofairintotheventuriisalsoreducedifthegasorificeisn’tcenteredintheventuriinlet and/or is not aligned with the venturi. Any misalignment of the burnerorificemaybecorrectedbybendingtheshuttercapholdingtheorificetotheinletoftheventuritube.

CEILING FANS, PORTABLE FANS OR LOGS INSTALLED NEAR COLD AIR RETURNSCeiling fans or oscillating floor type fans need to bemonitoredduring the operation of vent-free logs. If the air blows directlyinto theflamecausing it to impingeon the logset,orfirebox, itshouldbeturnedofforredirected.Ceilingfanscouldbereversedtopossiblyeliminateflameimpingement,andthefloorfancouldberedirected.Uponinstallation,beawareofanycoldairreturnsor vents in the proximity of the log set. Any draft created around avent-freelogsetcancausetheflametoimpingeonthelogandcreate a sooting situation.

WARNING: Donotallow fans toblowdirectly into thefireplace.Avoidanydraftsthatalterburnerflamepatterns.WARNING: Donotuseablowerinsert,heatexchangerinsertorother accessory not approved for use with this heater.CANDLESAvoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a sootlikesubstance.Burningcandleswhilethelogsetisoperatingmagnifiestheproblem.Itshouldbenotedthatcandles,ingeneral,produce soot. The amount of time burned and the quantity ofcandlesburnedwilldeterminetheamountofsootproducedanddeposited.MAKE OWNERS AWARE OF PROPER LOG SET OPERATIONProperly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.

IMPORTANT INSTALLATION GUIDELINES

Page 6: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 6

Installation on Rugs and TileIf this appliance is installed directly on carpeting, tile or other combustiblematerialotherthanwoodflooringtheapplianceshallbeinstalledonametalorwoodpanelextendingthefullwidthanddepth of the appliance. Thebasereferredtoabovedoesnotmeanthefire-proofbaseasused on wood stoves. The protection is for rugs that are extremely thickandlightcoloredtile.

Solid-fuelsshallnotbeburnedinamasonryorUL 127 factory-builtfireplaceinwhichanunventedroomheaterisinstalled.

Qualified Installing AgencyInstallationandreplacementofgaspiping,gasutilizationequipmentor accessories and repair and servicing of equipment shall beperformedonlybyaqualifiedagency.Theterm"qualifiedagency"meansanyindividual,firm,corporationorcompanywhicheitherinpersonorthrougharepresentativeisengagedinandisresponsiblefor(a)theinstallationorreplacementofgaspipingor(b)theconnection,installation,repairorservicingofequipment,whoisexperiencedinsuchwork,familiarwithallprecautionsrequiredandhascompliedwithalltherequirementsoftheauthorityhavingjurisdiction.

Commonwealth ofMassachusetts: The installationmust bemadebyalicensedplumberorgasfitterintheCommonwealthof Massachusetts.Sellersofunventedpropaneornaturalgas-firedsupplementalroom heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.In the Commonwealth of Massachusetts, unvented propane and naturalgas-firedspaceheatersshallbeprohibitedinbedroomsandbathrooms.

Theinstallationmustconformwithlocalcodesor,intheabsenceof local codes, with the National Fuel Gas Code, ANSI Z223.1.**Available from the American National Standards Institute, Inc. 1430 Broadway, New York, N.Y. 10018.

WARNINGThis appliance is equipped for (natural gas or propane) gas. Field conversion is not permitted.

Instructions to Installer1. Installer must leave instruction manual with owner after

installation.2. Installermusthaveownerfilloutandmailwarrantycardsupplied

with unvented room heater.3. Installer should show owner how to start and operate unvented

room heater.Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.Thisappliancemaybeinstalledinanaftermarket*manufactured(mobile)home,wherenotprohibitedbystateorlocalcodes.

*Aftermarket: Completionofsale,notforpurposeofresale,fromthe manufacturer.

Well Head Gas InstallationsSome natural gas utilities use “well head” gas. This may affect theBtuoutputoftheunitandpromotesooting.Unitsshallnotbeconverted to use well head gas.

This appliance is only for use with the type of gas indicated on the ratingplate.Thisapplianceisnotconvertibleforusewithothergases.

WARNINGAny change to this heater or its controls can be dangerous. Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

ThisseriesisdesigncertifiedinaccordancewithAmericanNationalStandardZ21.11.2bytheUnderwriter'sLaboratoriesasanUnventedRoomHeaterandshouldbeinstalledaccordingtotheseinstructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

VFP28IN3 and VFP20IN3 Series Only750 Millivolt SystemWhen you ignite the pilot, the thermocouple produces millivolts (electricalcurrent)whichenergizesthemagnetinthegasvalve.After 30 seconds to 1 minute time period you can release the gas controlknobandthepilotwillstayON.Allowyourpilotflametooperateanadditionalone(1)totwo(2)minutesbeforeyouturnthegascontrolknobfromthePILOTpositiontotheONposition.Thistimeperiodallowsthemillivolts(electricalenergy)tobuild-uptoasufficientlevelallowingthegascontroltooperateproperly.

ImportantAllcorrespondenceshouldrefertocompleteModelNumber,SerialNumberandtypeofgas.Attention: During initial use of ceramic log you will detect an odor as the ceramic log is cured. Also, during the curing process the ceramic log will burn with a yellow flame.NOTICE: Duringinitialfiringofthisunit,itspaintwillbakeout,andsmokewilloccur.Topreventtriggeringofsmokealarms,ventilatethe room in which the unit is installed.

INTRODUCTION

Page 7: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 7

SPECIFICATIONSVFP28IN3*L LP NAT

Input Btu/hr Maximum 28,000 28,000 Btu/hr Minimum 20,000 20,000

Orifice #52 #38Air Shutter Opening Full Open 1/8”

VFP28IN2*L LP NATInput Btu/hr Maximum 28,000 28,000 Btu/hr Minimum 20,000 20,000

Orifice #53 #42Air Shutter Opening Full Open 1/8"

VFP20IN2*L LP NATInput Btu/hr Maximum 20,000 20,000 Btu/hr Minimum 10,000 10,000

Orifice #55 #43Air Shutter Opening Full Open 1/8"

VFP20IN3*L LP NATInput Btu/hr Maximum 20,000 20,000 Btu/hr Minimum 15,000 14,000

Orifice #55 #49Air Shutter Opening Full Open 1/8"

VFP20IN3*L10 LP NATInput Btu/hr Maximum 10,000 10,000 Btu/hr Minimum 10,000 10,000

Orifice #64 #53Air Shutter Opening Full Open 1/8"

Accessories for VFP(20,28)IN3 (Millivolt) ModelsRemote Control

Accessories Description

FRBC Battery Operated Remote Control

FRBTC Battery Operated Remote Control with Thermostat

FRBTP BatteryOperatedProgrammableRemoteControl

FREC Electric Remote ControlFWS-1 Wall SwitchTRW RemoteWallThermostat(Wireless)

TMV Wall Thermostat, Millivolt - Reed Switch

DECORATIVE SURROUNDS AND FRONTS (1 REQUIRED)Model Description Use On

ContemporaryS256BL BlackSurround,6"WideSides VFP20INS336BL BlackSurround,6"WideSides VFP28INS253BL BlackSurround,3"WideSides VFP20INS333BL BlackSurround,3"WideSides VFP28IN

DF20GBL Decorative Front, Tempered Glass, Black VFP20IN

DF20MBL DecorativeFront,MetalFrame,Black VFP20IN

DF20LBL Decorative Front, Louver, Glass Frame(Includes6x6Surround) VFP20IN

DF28GBL Decorative Front, Tempered Glass, Black VFP28IN

DF28MBL DecorativeFront,MetalFrame,Black VFP28IN

DF28LBL Decorative Front, Louver, Glass Frame(Includes6x6Surround) VFP28IN

Traditional Cast IronSC256BL BlackSurround,6"WideSides VFP20INSC336BL BlackSurround,6"WideSides VFP28IN

Page 8: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 8

INSTALLATION IN A FIREPLACE1. Before beginning, remove door and log package fromunit.

Alsocheck tomakesure there isnohiddendamage to theunit.Takeaminuteandplanoutthegasandelectricalroute.Itisbesttostartwiththegaslinefirst,followedbytheelectricalsupplyrequirements.

2. Minimum fireplace opening requirements are shown in Figure 2ofthisinstallationmanual.Thefirebrick(refractory),glass doors, screen rails, screen mesh and log grates can beremovedfromafireplaceinordertogainminimumgasin-sertopeningrequirementspriortoinstallingthegasfireplaceinsert.

3. Althoughtheinsertdoesnotrequireahearthextension,onlyheat resistant materials such as stone, metal, tile, etc. should beused.Donotusevinyl,carpet,orwoodbasedproductswithin16inchesoftheinsertface.Donotobstructthelowerlouver(ifincluded),orotherventedopeningsontheinsert. Note:Theoriginalfireplacecannotbereturnedtosolidfuel use without returning the hearth extension to the specificationrequiredforasolidfuelfireplace.

4. Themetalfloorof thesolid fuelfireboxmayberemoved tofacilitate the installation of the insert. The side walls and top structureofthefireboxmaynotbealteredwiththeexceptionof removablebafflesanddampers.Smokeshields,shelvesandbafflesmayberemovedifattachedwithmechanicalfas-teners.Theoriginalfireplacecannotbereturnedtosolidfuelin this condition.

5. The insert surround is tested and approved with this gas in-sert and may cover existing air circulation vents or grills on the solidfuelfireplaceitisinstalledinto.Ifthesurrounddoesnotcover the entire ventilation grill surface, the exposed grill area shouldbeleftopen.

NOTICE: Cuttinganysheet-metalfromthedecommissionedfire-placeorfireboxfor the installationofzero-clearanceunventedfireplaceinsert,maybenecessaryandisacceptableinthisap-plication.

NOTICE: The following statement is also provided on a sepa-rate label plate in the instruction packet. Prior to installation of the fireplace insert, the installer must mechanically secure this warning plate to the inside of the fireplace for future ref-erence as required.

WARNING: The solid fuel fireplace has been converted for use with gas only and cannot be used for burning wood or solid fuels unless all original parts have been replaced and the fireplace has been reapproved by the authority having jurisdiction.

See"Positioning,LevelingandSecuringInsert"below.

6. Install the insert without the surround panels attached and makeallgasventingandelectricalconnections.

If the factory built fireplace does not have gas access holes provided, an access hole of 1 1/2” diameter (37.5mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This ac-cess hole must be plugged with a non-combustible insu-lation after the gas supply line has been installed.

7. Thesurroundpanelassembly is installedafter thefireplacehasbeeninstalledwithallthegasandelectricalconnectionscompleted(seePage22).Refertoinstructionsincludedwiththesurroundpanelkit.

Ensure there are no obstructions to side air passages of decorative trim once installed on insert.

Positioning, Leveling and Securing Insert1. Place the insert into positionNOTICE: Thefrontflangesoftheinsert(withoutsurroundpan-

els)shouldbesetatapproximately1" in frontof thefaceofthefireplace.

2. Leveltheinsertfromsidetosideandfronttoback.3. Ifnecessary,usethelevelingboltsincludedintheinstruction

pack.Screwthelegsintothenutsinstalledinthebottomofthe insert. Turn legs in until insert is level. NOTICE: Thebestwaytoaccessthelevelingboltlocationsistoremovetheburnerandfireboxbottom.

NOTICE: Ifdesired, it isacceptabletoattachmetalstrappingorbrackets(notprovided)fromthefireplacecavitytotheinsertouterjackettosecurethefireplaceinserttothefireplacehearthoropening.

Page 9: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 9

FIREPLACE INSERT DIMENSIONS

C

BA

D

E

F

Figure 1

Whenplanningafireplaceinsertinstallation,it’snecessarytodetermine:• Gassupplypiping.• Electricalconnections• Whetheroptionalaccessories-devicessuchasawallswitch

or remote control - are desired.

• Electricalsupplyrequirementsforblower.(120V,60Hz,1Amp)• Properopeningsizeoffireplacerequiredforinstallationof

thefireplaceinsert.

A

D

C

B

Figure 2

VF FIREPLACE INSERT DIMENSIONSMODEL A B C D E FVFP20IN 19 3/4" 18 5/16" 13 3/4" 29 1/4" 25 1/2" 16 1/8"VFP28IN 22 3/4" 21 5/16" 15 3/16" 32 1/4" 28 1/2" 17 7/8"

Fireplace Opening Dimensional Information/SizingMINIMUM FIREPLACE OPENING DIMENSIONS

MODEL HEIGHT A

FRONT WIDTH B

DEPTH C

REAR WIDTH D

VFP20IN 18 1/2" 26 3/4" * 13 3/4" 15 3/4"VFP28IN 21 1/2" 30 3/4" * 15 3/16" 19"

NOTICE: Thesearetheminimumdimensionsofafireplacethatthefireplaceinsertwillfitinto.Itallowsroomfortheboxand the fireplace surround to fit onto the front of theunit. It isnot intended tobeused for framingdimen-sions.

*NOTICE: Front Width B is the minimum and front opening dimen-sionrequiredtoensurepropersecuringoftheunit.

Page 10: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 10

Inplanningtheinstallationforthefireplace,itisnecessarytodeterminewheretheunitistobeinstalledandwhetheroptional accessories are desired. Gas supply piping should alsobeplannedatthistime.Thefireplacecanbemountedonanyofthesesurfaces:1. Aflathardcombustibleornon-combustiblesurface.2. A raisedplatformof combustibleornon-combustible

material.3. Four(4)cornersofthefireplacesocontactismadeon

allfourperimeteredgesonthebottomoftheunit. (Example:Four(4)concretemasonryblocks.)

Ifthefireplaceisinstalleddirectlyoncarpeting,tileorothercombustiblematerialotherthanwoodflooring,itshouldbeinstalled on a metal or wood panel extending the full width and depth of the unit.At this point, you should have decided what components toincludeinyourinstallation,andwherethefireplaceistobelocated.Ifthishasnotbeendone,stopandconsultyourdealer for assistance with this planning.

BUILT-IN FIREPLACE INSTALLATION

Thisunitisdesignedtobeinstalledinazero-clearanceen-closure.Thismeansthecombustiblematerialcancomeincontactwiththefirebox.Built-In Fireplace InstallationBuilt-in installation of this fireplace involves installing the fireplaceintoaframed-inenclosure.Thismakesthefrontofthefireplaceflushwithawall.Ifinstallingamantelabovethe fireplace,youmustfollowtheclearancesshowninFigures 10 through 12.Followtheinstructionsbelowtoinstallthefireplaceinthismanner.Frame in rough opening. Use dimensions show in Figure 3 for a conventional rough opening. Use dimensions shown in Figure 4 for corner rough opening. Be sure to provide gas line forfireplaceandelectricalpowerforoptionalblowerassembly.Although the insert does not require a hearth extension, onlyheat resistant materials such as stone, metal, tile, etc. should be used. Do not use vinyl, carpet, or wood based products

within 16 inches of the insert face. Do not obstruct the lowerlouver (if included), or other vented openings on the insert. NOTICE:The original fireplace cannot be returned to solid fueluse without returning the hearth extension to the specificationrequiredforasolidfuelfireplace.

1. Gaslineconnectionsmustbemadeatthistime.When facing the appliance, the gas supply will enter on the right-hand side. See "Gas Supply" pages 15 to 16.

2. Insertfireplaceintoenclosure.3. Levelfirebox.See"Positioning,LevelingandSecuring

Insert" on Page 8.4. Finishedwallsurfacewillbeflushtotheleadingedgeof

fireplacetopandsides.5. Ifused,thesurroundpanelassemblyis installedafter

the fireplace has been installed with all the gas andelectrical connection completed. See Page 22. Refer to instructionsincludedwiththesurroundpanelkit.

6. Installationofbuilt-infireplaceiscompleted.

D

25 5/8”650.9mm

B

51 1/4” (1301.8mm)

Figure 4Figure 3

Rough Opening for Installing in Wall Rough Opening for Installing in Corner

A B C D

VFP20IN 13 3/4"(349.3mm)

27 3/4" (704.9mm)

18 1/2" (470mm)

36 1/4" (920.8mm)

VFP28IN 16 3/4" (425.5mm)

30 1/2" (774.7mm)

22 1/2" (571.5mm)

36 1/4" (920.8mm)

Page 11: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 11

VFP20IN FIREPLACE WITH SURROUND DIMENSIONS

DF20MBL

40”

25 5/8”

1 3/4”

15/16”

DF20LBL

11 1/2”

34”

20 1/2”

4 1/4”

25”

DF20GBL

Page 12: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 12

VFP28IN FIREPLACE WITH SURROUND DIMENSIONS

DF28MBL

43”

28 5/8”

1 3/4”

15/16”

DF28LBL

14 1/2”

37”

23 1/2”

4 1/4”

28”

DF28GBL

Page 13: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 13

Watervaporisaby-productofgascombustion.Anunventedroomheaterproducesapproximatelyone(1)ounce(30ml)ofwaterforevery1,000BTU's(.3KW's)ofgasinputperhour.Unventedroomheatersarerecommendedassupplementalheat(aroom)ratherthanaprimaryheatsource(anentirehouse).Inmostsupplemental heat applications, the water vapor does not create a problem.Inmostapplications,thewatervaporenhancesthelowhumidity atmosphere experienced during cold weather.

The following steps will help insure that water vapor does not becomeaproblem.1. Be sure the heater is sized properly for the application, including

amplecombustionairandcirculationair.2. Ifhighhumidityisexperienced,adehumidifiermaybeusedto

help lower the water vapor content of the air.3. Do not use an unvented room heater as the primary heat source.

Thisheatershallnotbeinstalledinaconfinedspaceorunusuallytight construction unless provisions are provided for adequatecombustionandventilationair.

Aconfinedspaceisanareawithvolumelessthan50cubicfeetper1,000Btuhofthecombinedinputratesofallappliancesdrawingcombustionair fromthatspace.Smallareassuchasequipmentroomsareconfinedspaces.Furnacesinstalledinaconfinedspacewhich supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts. A confinedspacemusthave2openingsintothespaceforcombus-tionair.Oneopeningmustbewithin12inchesoftheceilingandtheothermustbewithin12inchesofthefloor.Therequiredsizingoftheseopeningsisdeterminedbywhetherinsideoroutsideairisusedtosupportcombustion,themethodbywhichtheairisbroughttothespace(verticalorhorizontalduct)andbythetotalinputrateof all appliances in the space.

Unusually Tight ConstructionTheairthatleaksarounddoorsandwindowsmayprovideenoughfreshairforcombustionandventilation.However,inbuildingsofunusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction

where:a. Walls and ceilings exposed to the outside atmosphere have

a continuous water vapor retarder with a rating of one perm orlesswithopeningsgasketedorsealed,and

b. Weather-strippinghasbeenaddedonopenablewindowsand doors, and

c. Caulkingor sealantsareapplied toareassuchas jointsaroundwindowanddoorframes,betweensoleplatesandfloors,betweenwall-ceilingjoints,betweenwallpanels,atpenetrationsforplumbing,electrical,andgaslines,andatother openings.

Ifyourhomemeetsallofthethreecriteriaabove,youmustprovideadditional fresh air. See “Ventilation Air From Outdoors,” page 14.

Determining if You Have a Confined or Unconfined SpaceUsethisworksheettodetermineifyouhaveaconfinedorunconfinedspace.Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills betweentherooms.

1. Determinethevolumeofthespace(lengthxwidthxheight). Length x Width x Height = cu.ft.(volumeof

space)Example:Spacesize16ft.(length)x10ft.(width)x8ft.(ceiling

height)=1,280cu.ft.(volumeofspace) If additional ventilation to adjoining room is supplied with grills

or openings, add the volume of these rooms to the total volume of the space.

2. Divide thespacevolumeby50cubic feet todetermine themaximum BTU/Hr the space can support.

(volumeofspace)÷50cu. ft.=(maximumBTU/Hr the space can support)

Example:1,280cu.ft.(volumeofspace)÷50cu.ft.=25.6or25,600(maximumBTU/Hrthespacecansupport)

3. AddtheBTU/Hrofallfuelburningappliancesinthespace. Vent-free heater BTU/Hr Gas water heater BTU/Hr Gas furnace BTU/Hr Vented gas heater BTU/HrGasfireplacelogs BTU/Hr Other gas appliances*+ BTU/Hr Total = BTU/Hr

Example: Vented gas heater 20,000 BTU/Hr Vent-free heater + 18,000 BTU/Hr Total = 38,000 BTU/Hr *Do not include direct-vent gas appliances. Direct vent draws combustionairfromtheoutdoorsandventstotheoutdoors.

4. Compare the maximum BTU/Hr the space can support with the actual amount of BTU/Hr used.

BTU/Hr(maximumthespacecansupport) BTU/Hr(actualamountofBTU/Hrused) Example: 25,600BTU/Hr(maximumthespacecansupport) 38,000BTU/Hr(actualamountofBTU/Hrused)

WARNING: If the area inwhich the heatermay be operated issmallerthanthatdefinedasanunconfinedspaceorifthebuildingis of unusually tight construction, provide adequate combustionandventilationairbyoneofthemethodsdescribedintheNational Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation,orapplicablelocalcodes.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR

Page 14: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 14

Thespaceintheaboveexampleisaconfinedspacebecausetheactual BTU/Hr used is more than the maximum BTU/HR the space can support. You must provide additional fresh air. Your options are as follows:A. Reworkworksheet,addingthespaceofanadjoiningroom.If

theextraspaceprovidesanunconfinedspace,removedoortoadjoiningroomoraddventilationgrillsbetweenrooms.SeeVentilation Air From Inside Building.

B. Vent room directly to the outdoors. See Ventilation Air From Outdoors.

C. InstallalowerBTU/Hrheater,iflowerBTU/Hrsizemakesroomunconfined.

If the actual BTU/Hr used is less than the maximum BTU/Hr the spacecansupport,thespaceisanunconfinedspace.Youwillneedno additional fresh air ventilation.

WARNINGYou must provide additional ventilation air in a confined space.

VENTILATION AIRVentilation Air From Inside Building (Figure 5)Thisfreshairwouldcomefromanadjoiningunconfinedspace.Whenventilatingtoanadjoiningunconfinedspace,youmustprovidetwopermanent openings: one within 12" of the ceiling and one within 12"oftheflooronthewallconnectingthetwospaces(seeoptions1 and 2, Figure 5). You can also remove door into adjoining room (seeoption3,Figure5).Eachventilationgrilloropeningshallhaveaminimumfreeareaofonesquareinchper1,000BTUHofthetotalinputratingofthegasequipmentintheconfinedspace.

Figure 5

WARNINGRework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

VENTILATION AIR FROM OUTDOORS (Figure 6)Provideextrafreshairbyusingventilationgrillsorducts.Youmustprovide two permanent openings: one within 12" of the ceiling and onewith12"ofthefloor.Connecttheseitemsdirectlytotheoutdoorsor spaces open to the outdoors. These spaces include attics and crawl spaces. In most cases for direct communication with the outdoors or direct communication through a vertical duct a free areaopeningofonesquareinchper4,000BTU/Hrofheaterinputrating for each grill. If a horizontal duct is used, a grill free area or ductopeningshallhaveafreeareaopeningofonesquareinchper2,000 BTU/Hr for each grill. Follow the National Fuel Code ANSI Z223.1/NFPA54, Air for Combustion and Ventilation for requiredsize of ventilation grills or ducts.IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Figure 6

PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR (CONT'D)

A1 A2

B1 B2

A1 x B1 = C1A2 x B2 = C2C1+C2=Sq.In.Required

Example:Fora30,000BTUHeater,1sqinper1,000BTUequals30sq.in.ofopening.

(A1)5in2x(B1)3in2=(C1)15in2

(A2)5in2x(B2)3in2=(C2)15in2

(C1)15in2+(C2)15in2 = 30in2

Figure 7

Page 15: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 15

Figure 8

Thegaspipelinecanbebroughtinthroughtherightorleftsideofthe appliance. The insert has a Flexline with shutoff valve located on the right side when facing the unit. See Figures 8 and 9. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1or.2)installationcode.

Installing the Main Gas Shut-OffEach appliance should have its own manual gas shut-off.Amanualmaingasshut-offshouldbelocatedinthevicinityoftheunit.Wherenoneexists,orwhereitssizeorlocationisnotadequate,contact your local authorized installer for installation or relocation.Compoundsusedonthreadedjointsofgaspipingshallberesistanttotheactionofliquefiedpetroleumgases.Thegaslinesmustbecheckedforleaksbytheinstaller.Thisshouldbedonewithasoapsolutionwatchingforbubblesonallexposedconnections,andifunexposed,apressuretestshouldbemade.

Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!NOTICE: Themillivoltgascontrolsareequippedwithacapturedscrew type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

Whenusingcopperorflexconnectoruseonlyapprovedfittings.Theapplianceandit’sindividualshutoffvalvemustbedisconnectedfrom supply piping system during any pressure testing of that system attestpressuresinexcessof1/2psig(3.5kPa).Theappliancemustbeisolatedfromthegassupplypipingsystembyclosingitsindividualmanualshutoffvalveduringanypressuretestingofthegassupplypipingsystemattestpressuresequaltoorlessthan1/2psig(3.5kPa).Attention! If one of the procedures results in pressures in excess of 1/2psig(14"w.c.)(3.5kPa)onthefireplacegasvalve,itwillresultin a hazardous condition.

NOTICE:Neveruseplasticpipe.Checktoconfirmwhetheryourlocalcodesallowcoppertubingorgalvanized.NOTICE: Since some municipalities have additional local codes, it isalwaysbesttoconsultyourlocalauthorityandinstallationcode.The use of the following gas connectors is recommended:— ANSZ21.24ApplianceConnectorsofCorrugatedMetalTubing

and Fittings.— ANSZ21.45AssembledFlexibleApplianceConnectorsofOther

Than All-Metal ConstructionTheaboveconnectorsmaybeusedifacceptablebytheauthorityhavingjurisdiction.ThestateofMassachusettsrequiresthataflexibleappliance connector cannot exceed three feet in length.

Recommended Gas Pipe Diameter

Pipe LengthSchedule 40 Pipe Inside Diameter

Tubing, Type LOutside Diameter

Nat. L.P. Nat. L.P.

0-10ft0-3m

1/2"12.7mm

3/8"9.5mm

1/2"12.7mm

3/8"9.5mm

11-40ft4-12m

1/2"12.7mm

1/2"12.7mm

5/8"15.9mm

1/2"12.7mm

41-100ft13-30m

1/2"12.7mm

1/2"12.7mm

3/4"19mm

1/2"12.7mm

101-150ft31-46m

3/4"19mm

1/2"12.7mm

7/8"22.2mm

3/4"1.9 mm

GAS SUPPLY

GAS FLEX LINE WITH

SHUTOFF VALVE

(PROVIDED)

FRONT OF

INSERT

RIGHT SIDE OF INSERT

Figure 9

Page 16: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 16

GAS SUPPLY (CONT'D)

CLEARANCESCOMBUSTIBLE MATERIALNogreetingcards,stockingsorornamentationofanytypeshouldbeplacedonorattached to the fireplace.Theflowof heat canignitecombustibles.

Figure 10

Propane gas will have a manifold pressure approximately 10.0"w.c. at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. for the purpose of input adjustment to a maximum of 13.0"w.c.

A test gage connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch N.P.T. plugged tapping.

MILLIVOLT CONTROL VALVEThevalveregulatorcontrolstheburnerpressurewhichshouldbecheckedatthepressuretestpoint.Turncapturedscrewcounterclockwise2or3turnsandthenplacetubingtopressuregaugeovertestpoint(Usetestpoint“A”closesttocontrolknob).Aftertakingpressurereading,besureandturncapturedscrewclockwisefirmlytore-seal.Donotovertorque.Checkforgasleaks.

CHECKING MANIFOLD PRESSUREMILLIVOLT VALVES Natural gas will have a manifold pressure of approximately 3.5" w.c. for maximum input or 1.7" w.c. for minimum input at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 4.5" w.c. for the purpose of input adjustment to a maximum of 10.5" w.c.

Propane gas will have a manifold pressure approximately 10.0"w.c. (2.49kPa)formaximuminputor4.9"w.c.forminimuminputatthepressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. for the purpose of input adjustment to a maximum of 13.0"w.c.

HYDRAULIC THERMOSTAT VALVES Natural gas will have a manifold pressure of approximately 6.0" w.c. at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 7.0" w.c. for the purpose of input adjustment to a maximum of 10.5" w.c.

8”

MINIMUM CLEARANCETO PERPENDICULARCOMBUSTIBLE SIDE-WALL

Page 17: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 17

FINISHED WALL

FLAT MANTEL SHELF

2”

15”

11”

4”

6”

8”

10”

12”

13”

17”

19”

21”

VFP20 Series Figure 11

FINISHED WALL

FLAT MANTEL SHELF

2”

20”

16”

4”

6”

8”

10”

12”

18”

22”

24”

26”

VFP28 Series Figure 12

CLEARANCES (CONT'D)

Page 18: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 18

CLEARANCES (CONT'D)

FLOOR

26” MIN.

CEILING

NO MANTEL

TOP OF FIREPLACE OPENING

FLOOR

26” MIN.

CEILING

NO MANTEL

TOP OF FIREPLACE OPENING

Surround Clearances Figure 13

Glass Front Clearances Figure 14

Figures 13 and 14 pertaintoVFP(20,28)INSeries.

Page 19: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 19

Donotattachcombustiblematerialtothemantelofyourfireplace.Thisisafirehazard.

Figure 15

Nogreetingcards,stockingsorornamentationofanytypeshouldbeplacedonorattachedtothefireplace.Thisisaheatingappliance.Theflowofheatcanignitecombustibles.

Figure 16

COMBUSTIBLE MATERIALS

Page 20: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 20

WIRING THE FIREPLACENOTICE: Electrical wiring must be installed by a licensed electrician.CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-VENT ACCIDENTAL FIREPLACE OPERATION.Installation of Alternate Surround Panel ON/OFF Switch on the millivolt control valve only.AnON/OFFswitchandwireassemblyareprovided.Theyarein-cludedintheinstructionpacket.Do not cut wire or insulation on metal edges.Note: Refer to surround panel installation section on page 22 for additional information on attachment.Standard Surrounds DF(20,28)LBL1. FindthecoiledlowvoltagewireassemblyandON/OFFswitch

locatedintheinstructionpacket.

2. Attachtheflagterminalendstothe“TH/TP”and“TH”terminalsonthefrontterminalblockofthegasvalve.See Figure 22.

3. Runthelowvoltagealternateswitchwiresupthebackoftheright or left surround panel. Then secure the wires with wire clips provided. See Figure 17.

WIRING FROM

MILLIVOLT GAS

VALVE

ON/OFF

SWITCH

ASSEMBLY

Right Side Installation Left Side Installation

ON/OFF

SWITCH

ASSEMBLY

Figure 17Insert ON/OFF switch into side panel then attach wire assembly from valve terminals.4. Removetheswitchknockoutonthesidesurroundpanel,then

install the ON/OFF switch.

5. Connect the low voltage wires from the gas valve to the ON/OFF switch.

6. Attachthesurroundpanelassemblytotheinsert.Placethesurroundpanelassemblyagainst the faceof the insertandalignthe lowerretainingtabswith thenotchesonthe insertsides.Liftthesurroundpanelassemblyslightlyuntilthebot-tomreturnflange(toppanel)ispositionedoverthetopflangeon the insert.Thissecures thesurroundpanelassembly tothe insert without screws.

Traditional Cast Iron Surrounds1. FindthecoiledlowvoltagewireassemblyandON/OFFswitch

locatedintheinstructionpacket.

2. Attachtheflagterminalendstothe“TH/TP”and“TH”terminalsonthefrontterminalblockofthegasvalve.See Figure 19.

3. Runthelowvoltagealternateswitchwiresupthebackoftheright or left cast surround leg. Then secure them with the wire clips provided.

4. InstalltheswitchbracketwithscrewsasshowninFigure 18 tothebackofthecastsurroundleg.

Figure 18NOTICE: For right side leg installation, reverse switch posi-

tion in bracket.5. Install ON/OFF switch, and connect low-voltage wires from

gas valve.

6. Attachcastsurroundpanelassemblytotheinsert.Placethecast surround assembly against the face of the insert andalignthe lowerretainingtabswith thenotchesonthe insertsides.Liftthecastsurroundassemblyslightlyuntilthebottomreturnflange(toppanel)ispositionedoverthetopflangeonthe insert. This secures the cast surround assembly to theinsert without screws.

WIRES FROM ON/OFFSWITCH INSTALLED INLEFT OR RIGHT SIDESURROUND PANELS

NOTE: TO OPERATE INSERT WITH SIDE PANELON/OFF SWITCH, BE SURE TO PLACE THE MAINSWITCH (TO THE RIGHT SIDE OF GAS VALVE) TO “ ”POSITION

OFF

TH/TP

TP

TH

Figure 19

ALTERNATE ON/OFF SWITCH INSTALLATION

Page 21: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 21

WIRING THE FIREPLACE

WARNINGElectrical wiring must be installed by a licensed electri-cian.

WARNINGDisconnect remote controls if you are absent for extended time periods. This will prevent accidental fireplace opera-tion.

Installation of Alternate Surround Panel ON/OFF Switch on the millivolt control valve only.AnON/OFFswitchandwireassemblyareprovided.Theyarein-cludedintheinstructionpacket.Do not cut wire or insulation on metal edges.Notice: Refer to surround panel installation section in the Installation Instructions supplied with the surround for addi-tional information on attachment.DF(20,28)MBL 1. FindthecoiledlowvoltagewireassemblyandON/OFFswitch

locatedintheinstructionpacket.

2. Attachtheflagterminalendstothe“TH/TP”and“TH”terminalsonthefrontterminalblockofthegasvalve.See Figure 21.

3. Runthelowvoltagealternateswitchwiresupthebackoftheright or left surround panel. Then secure the wires with wire clips provided. See Figure 20.

ON/OFFSWITCH

WIRING FROMMILLIVOLT GAS

VALVE

Figure 20 (DF20MBL Shown)Insert ON/OFF switch into side panel then attach wire assem-

bly from valve terminals.4. Remove theswitchknockouton theDF(20,28)BLsurround,

theninstalltheON/OFFswitchintotheswitchbracket.

5. Connect the low voltage wires from the gas valve to the ON/OFF switch.

NOTICE: The minimum clearance to the floor when using aDF(20,28)MBLsurroundis2inches.Thisclearanceal-lows access to the ON/OFF switch.

6. Attachthesurroundpanelassemblytotheinsert.Placethesurroundpanelassemblyagainst the faceof the insertandalignthe lowerretainingtabswith thenotchesonthe insertsides.Liftthesurroundpanelassemblyslightlyuntilthebot-tomreturnflange(toppanel)ispositionedoverthetopflangeon the insert.Thissecures thesurroundpanelassembly tothe insert without screws.

WIRES FROM ON/OFFSWITCH INSTALLED INLEFT OR RIGHT SIDESURROUND PANELS

NOTE: TO OPERATE INSERT WITH SIDE PANELON/OFF SWITCH, BE SURE TO PLACE THE MAINSWITCH (TO THE RIGHT SIDE OF GAS VALVE) TO “ ”POSITION

OFF

TH/TP

TP

TH

Figure 21

ALTERNATE ON/OFF SWITCH INSTALLATION (CONT'D)

Page 22: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 22

SURROUND PANEL INSTALLATIONINSTALLING THE TRIM SURROUNDSCombustiblematerialsMUSTNEVERoverlapontothefrontface.

WARNING: when finishing the fireplace insert, never ob-struct or modify the air inlet/outlet louvers on the fire-place insert in any manner.

NOTE: INSTALL SURROUND PANELSSO THAT THE TOP PANELRETURN FLANGE SLIDE’SOVER THE TOP FLANGE ONTHE INSERT

1” Ref.

SURROUND PANEL ASSEMBLY

ENGAGE SIDE PANELHOOKS WITH THENOTCHES PROVIDED ONTHE SIDE FLANGES

Figure 22

Figure 23

Page 23: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 23

BLOWER ACCESSORY INFORMATION

BLOWER ASSEMBLY

FAN SPEED CONTROL

MILLIVOLT VALVE

THE FAN CONTROL SWITCH IS

CLIPPED BETWEEN THE BURNER

BASE AND VALVE BRACKET

PIEZO IGNITOR

REMOTE/OFF/ON SWITCH

The appliance, when installed must be electrically con-nected and grounded in accordance with local codes or, in the absence of local codes.National Electrical Code, ANSI/NFPA No. 70.Should this blower require servicing, the power supply must be disconnected. For rewiring of any replacement components, refer to Figures 24 and 25 and the parts list on pages 42 through 45.

BLOWER ACCESSORYOperationThe fireplace insert is equipped with a factory installed bloweraccessory that includes a fan control switch, plus a rheostat (speedcontrol).Thespeedcontrolknobislocatedbehindthelowerlouverattheright side of the insert.From a cold start, the temperature activated fan control switch will normally take5-10minutes toheatupandenergize theblower.Starttheblowerinthe"High"setting.Oncetheblowerisenergized,adjusttheblowerspeedcontrolasdesired, then replace the lower louver.When the insert is shut off, itmay take 30-40minutes for theheated unit to dissipate (cool down) enough for the blower toshutoffautomatically.Note:TheblowershutofftimeswillvaryonblowerspeedandBTUinputlevelsettingcontrolbyadjustmentoftheHI/LOknoblocatedonthegasvalve.

Blower removal instructionsServicingorremovaloftheblowersystemmustbeperformedbyaqualifiedserviceperson.Iftheblowerassemblymustbereplaced,thefollowingstepsarerecommended for removal:

1. Turn off gas and disconnect the electrical supply.2. Removethescreendoorassembly.3. Remove the log set.4. Removethefrontsurroundpanelassemblybyliftingupward

and outward to detach.6. Removetheinsertfromthefireplacecavitybypullingforward

on the insert.7. Astheinsertismovedoutward,thegaslinemayneedtobe

disconnectedattheinsertshutoffvalve.Ifso,makesurethemain gas line is shut off that supplies gas to the insert.

8. Once the insert is pulled out, the blower assembly can beremovedbylocatingthe(6)screwsonthelowerbackoftheinsertthatretainstheblowerbaseplate.

9. When the screws are removed, gently pull the blowerassemblyoutward.

10. Disconnect the two ¼” wire terminals from the motor.11. Removethe(4)screwsthatretaintheblowerassemblytothe

baseplate,andsetbloweraside.12. Install the replacement blower, and re-install the insert by

reversingabovesteps.

FAN SPEED CONTROL

REMOTE/OFF/ON SWITCH

PIEZO IGNITORMILLIVOLT VALVE

THE FAN CONTROL SWITCH ISCLIPPED BETWEEN THE BURNERBASE AND FIREBOX BOTTOM BLOWER ASSEMBLY

VFP28IN

VFP20INFigure 24

Figure 25

Page 24: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 24

Beforeyoubegin:Donot,handletheselogswithyourbarehands!Alwayswearglovestopreventskinirritation.Afterhandlinglogs,wash your hands gently with soap and water.All LogsThe positioning of the logs is critical to the safe and clean operation ofthisheater.Sootingandotherproblemsmayresultifthelogsarenotproperlyandfirmlypositionedintheappliance.

WARNING: Failure to position the parts in accordance with this diagramorfailuretouseonlypartsspecificallyapprovedwiththis appliance may result in property damage or personal injury.

PROPER INSTALLATION SEQUENCE:(Figure 26) 1. Placeback(#1)logbetweenrearlogsupportandburnerpan.2. Placeleft,frontlog(#2)ontotwo(2)left,frontpinsonburner

pan.3. Placeright,frontlog(#3)ontotwo(2)right,frontpinsonburner

pan.4. Compare the completed log installation with the appropriate

photo from page 47.Review previous steps tomake anynecessary adjustments.

5. Log placement is completed.6. Attachlogplacementplatetocableholdinglightinginstructions

for future reference.

Attention: Do not use Figure 26 to order replacement logs. Refer to Page 46 Parts List and Parts View to order logs for your appropriate modelnumber.Applyloosematerial(glowingembers)perappropriateInstallationInstructionsandOwner'sManual.Replacementofloosematerial(glowingembers)mustbepurchasedfromanauthorizeddistributor.Application of excess loosematerial (glowing embers)mayadversely affect performance of the heater. Rockwoolcanbeadded toburners foraglowingembereffect.Applyloosematerial(glowingembers)onlyonlocationsshownonPage25.Replacementofloosematerial(glowingembers)mustbepurchased from Empire Comfort Systems, Inc. Application of excess loosematerial(glowingembers)mayadverselyaffectperformanceof the heater.

WARNING:All previously applied loosematerialmust beremoved prior to reapplication.

Replacement Loose Material (glowing embers) Part Number: 15998

NOTICE: AsinglelayerofembersistobeusedwhenapplyingPlatinumBrightEmbers(aloneorincombinationwithproductionembers)totheburner.

Log PlacementFigure 26

The following WARNING applies when log set is installed onto an unventedgasburnerassembly.

WARNING: Thisapplianceisequippedfor(naturalorpropane)gas. Field conversion is not permitted.

2

1

3

VFP20IN LOG PLACEMENT

Page 25: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 25

Do

notcover

any

larg

ere

ar

port

sw

ith

loose

mate

rial(g

low

ing

em

bers

).

VFP20IN EMBER PLACEMENT PHOTOS

Page 26: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 26

Beforeyoubegin:Donot,handletheselogswithyourbarehands!Alwayswearglovestopreventskinirritation.Afterhandlinglogs,wash your hands gently with soap and water.All LogsThe positioning of the logs is critical to the safe and clean operation ofthisheater.Sootingandotherproblemsmayresultifthelogsarenotproperlyandfirmlypositionedintheappliance.

WARNING: Failure to position the parts in accordance with this diagramorfailuretouseonlypartsspecificallyapprovedwiththis appliance may result in property damage or personal injury.

PROPER INSTALLATION SEQUENCE:

(Figure 27) 1. Placerearlog(#1)ontotwo(2)pinsonrearlogsupport.2. Placeleft,frontlog(#2)ontotwo(2)left,frontpinsonburner

pan.3. Placeright,frontlog(#3)ontotwo(2)right,frontpinsonburner

pan.4. PlaceYBranch(#4)ontotwo(2)pinsonrearlog.5. Compare the completed log installation with the photo on page

27.Reviewpreviousstepstomakeanynecessaryadjustments.6. Log placement is completed.7. Attachlogplacementplatetocableholdinglightinginstructions

for future reference.

Attention: Do not use Figure 27 to order replacement logs. Refer to Page 46 Parts List and Parts View to order logs.Rockwoolcanbeadded toburners foraglowingembereffect.Applyloosematerial(glowingembers)onlyonlocationsshownonPage27.Replacementofloosematerial(glowingembers)mustbepurchased from Empire Comfort Systems, Inc. Application of excess loosematerial(glowingembers)mayadverselyaffectperformanceof the heater.

WARNING:All previously applied loosematerialmust beremoved prior to reapplication.

8. Installfrontframeassembly.

Replacement Loose Material (glowing embers) Part Number: 15999

NOTICE: AsinglelayerofembersistobeusedwhenapplyingPlatinumBrightEmbers(aloneorincombinationwithproductionembers)totheburner.

Log PlacementFigure 27

The following WARNING applies when log set is installed onto an unventedgasburnerassembly.

WARNING:Thisapplianceisequippedfor(naturalorpropane)gas. Field conversion is not permitted.

VFP28IN LOG PLACEMENT

1

2

3

4

Page 27: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 27

Ph

oto

1P

ho

to2

Ph

oto

3P

ho

to4

Do

notcover

any

larg

ere

ar

port

sw

ith

loose

mate

rial(g

low

ing

em

bers

)

Do

notcover

any

larg

efr

ontport

sw

ith

loose

mate

rial(g

low

ing

em

bers

)

VFP28IN EMBER PLACEMENT PHOTOS

Page 28: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 28

1. Setthermostat(gascontrolknob)tolowestsetting.2. Turnoffallelectricpowertoapplianceifserviceistobe

performed(ifapplicable).

3. Pushingascontrolknobslightlyandturnclockwise to "OFF". Do not force.

1. STOP!Readthesafetyinformationabove.2. Setthermostat(gascontrolknob)tolowestsetting.3. Turn off all electric power to the appliance (if appli-

cable).4. Push ingascontrol knobslightlyand turn clockwise

to "OFF". Do not force.

5. Waitten(10)minutestoclearoutanygas.Thensmell

forgas,includingnearthefloor.Ifyousmellgas,STOP!Follow"B"inthesafetyinformationabove.Ifyoudon'tsmell gas, go to the next step.

6. Find pilot - the pilot is in front of the rear log.

7. Turn gas control knob counterclockwise to "PILOT."

8. Pushingascontrolknoballthewayandholdin.Repeat-edlypushthepiezoignitorbuttonuntilpilotislit(oruseamatchtolightpilot).Continuetoholdthecontrolknobinforaboutone(1)minuteafterthepilotislit.Releaseknobanditwillpopbackup.Pilotshouldremainlit.Ifit

goes out, repeat steps 4 through 8.• Ifknobdoesnotpopupwhenreleased,stopand

immediately call your service technician or gas supplier.

• If thepilotwillnotstay litafterseveral tries, turnthegascontrolknobto"OFF"andcallyourservicetechnician or gas supplier.

9. Attention!GascontrolhasanINTERLOCKlatchingde-vice. When the pilot is initially lit and the safety magnet isenergized(pilotstays"ON")theINTERLOCKlatchingdevicebecomesoperative.Ifthegascontrolisturnedtothe"OFF"positionorgasflowtotheapplianceisshutoff,thepilotcannotberelighteduntilthesafetymagnetisde-energized(approximately60seconds).Therewillbeanaudible"click"whenthesafetymagnetinthegascontrol is de-energized. Pilot can now be relighted.Repeat steps 4 through 8.

10.Turn gas control knob counterclockwise to "5".

11. Turnonallelectricpowertoappliance(ifapplicable).12.Setthermostat(gascontrolknob)todesiredsettingfrom

"5" to "1".

A. This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch; Do not use any phone in your building.• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Page 29: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 29

A. This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch; Do not use any phone in your building.• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

1. Openbottomlouverassembly.2. Set REMOTE/OFF/ON switch to "OFF."3. Turn off all electric power to the appliance if service is

tobeperformed(ifapplicable).

4. Push ingascontrol knobslightlyand turn clockwise to "OFF." Do not force.

5. Closebottomlouverassembly.

1. STOP!Readthesafetyinformationlabel.2. Openbottomlouverassembly.3. Set REMOTE/OFF/ON switch to

"OFF."4. Turn off all electric power to the

appliance(ifapplicable).5. Pushingascontrolknobslightly

and turn clockwise to "OFF." NOTE:Knobcannotbeturnedfrom"PILOT"to"OFF"unlessknobis pushed in slightly. Do not force.

6. Waitten(10)minutestoclearoutanygas.Then smell for gas, including nearthefloor.Ifyousmellgas,STOP!Follow"B"inthesafetyinformationabove.Ifyoudonotsmell gas, go to the next step.

7. Findpilot - Followmetal tubefrom gas control. The pilot is behindtheburnerontheright

side.8. Turngascontrolknobcounterclockwise to

"PILOT."9. Pushincontrolknoballthewayandholdin.Repeat-

edly push the Piezo Ignitor Button until the pilot is lit. Continuetoholdthecontrolknobinforaboutone(1)minuteafterthepilotislit.Releaseknob,anditwillpopbackup.Pilotshould remain lit. If itgoesout,repeat steps 5 through 9.• Ifknobdoesnotpopupwhenreleased,STOPand

IMMEDIATELYcallaqualifiedservicetechnicianor gas supplier.

• Ifthepilotwillnotstaylitafterseveraltries,turnthegascontrolknobto"OFF"andcallyourser-vice technician or gas supplier.

10.Turngascontrolknobcounterclockwise to "ON."

11. Set REMOTE/OFF/ON switch to desired setting. 12.Turnonallelectricpowertotheappliance(ifappli-

cable).13.Closebottomlouverassembly.

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE(LPG)

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE(LPG)

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE(LPG)

MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Page 30: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 30

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch; Do not use any phone in your building.• Immediately call your gas supplier from a neighbor's

phone. Follow the gas supplier's instructions.• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

1. Openbottomlouverassembly(ifapplicable).2. Set REMOTE/OFF/ON switch to OFF.3. Turn off all electric power to the appliance if service is

tobeperformed(ifapplicable).

4. Push ingascontrol knobslightlyand turn clockwise to "OFF." Do not force.

5. Closebottomlouverassembly(ifapplicable).

1. STOP!Readthesafetyinformationabove.2. Openbottomlouverassembly,

(ifapplicable).3. Set REMOTE/OFF/ON switch

to "OFF."4. Turn off all electric power to

theappliance(ifapplicable).5. Push in gas control knob

slightly and turn clockwise to "OFF."

6. Wait ten (10)minutes to clear out anygas. Then smell for gas, including near the floor. If you smell gas, STOP!Follow"B"inthesafetyinformation above. If you donot smell gas, go to the next step.

7. Findpilot-Followmetaltubefrom gas control. The pilot is locatednexttotheburner,nearthe right side.

8. Turn gas control knob counterclockwise to "PILOT."

9. Pushincontrolknoballthewayandholdin.Repeat-edly push the Piezo Ignitor Button until the pilot is lit. Continuetoholdthecontrolknobinforaboutone(1)minuteafterthepilotislit.Releaseknob,anditwillpopbackup.Pilotshouldremainlit. If itgoesout,repeatsteps 5 through 9.• Ifknobdoesnotpopupwhenreleased,STOPand

IMMEDIATELYcallaqualifiedservicetechnicianorgas supplier.

• If thepilotwillnotstay litafterseveral tries, turnthegascontrolknobto"OFF"andcallyourservicetechnician or gas supplier.

10.Turn gas control knob counterclockwise to "ON."

11. Set REMOTE/OFF/ON switch to desired setting.12.Turn on all electric power to the appliance (if appli-

cable).13.Closebottomlouverassembly(ifapplicable).

OF

F

PILOTO

N

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE(LPG)

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION.

THERMOCOUPLE(NATURAL)

ELECTRODE

PILOT

THERMOPILE

REMOTE

OFF

ON

THERMOCOUPLE(LPG)

10,000 BTU MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Page 31: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 31

TO TURN OFF GAS TO FIREPLACE

1. STOP!Readthesafetyinformationabove.2. Turn OFF electric power to the appliance.3. Removefrontsurroundpanelassemblyorbottomlouver if

included.4. Turngascockcounterclockwise to “On” position.5. Waitten(10)minutestoclearoutanygas.Thensmellforgas,

includingnearthefloor.Ifyousmellgas,STOP!Follow“B”inthesafetyinformationaboveonthispage.Ifyoudonotsmellgas, go to the next step.

6. Turn ON electric power to the appliance.7. Findpilot-Followmetaltubefromgascontrol.Thepilot is

behindtheburnerontherightside.8. Turnmainflame toon. If thepilotdoesnot lightwithin60

seconds, stop and go to Step 5.

9. Refer to remote control instructions for detailed information, control features, and operation. Note: There is a CPI/IPI switch behindtherightsidepanelthatallowsforacontinuousstandingpilot mode or an intermittent pilot mode. See appliance manual forlocationofthisswitch.Ifthepilotorburnerdoesnotstaylit(inthestandingpilotmode),stopandimmediatelycallaqualifiedservicetechnicianorgassupplier.

10. Iftheburnerorpilotdoesnotoperateproperlyafterseveraltries,turnthegascockclockwise to “OFF” and call your service technician or gas supplier.

11. Replacethefrontsurroundassemblyorclosebottomlouverassembly.

12. Operation of the gas valve is controlled by a manual on/off switch or a hand held remote control. Refer to remote instructions for detailed operation information.

FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING:Ifyoudonotfollowtheseinstructionsexactly,afireorexplosionmayresult

causing property damage, personal injury or loss of life.

A.Thisappliancehasapilotwhichmustbelightedbyhand.Whenlighting the pilot, follow these instructions exactly.

B. Before lighting smell all around the appliance area for gas. Be suretosmellnexttothefloorbecausesomegasisheavierthanairandwillsettleonthefloor.

What To Do If You Smell Gas• Donottrytolightanyappliance.• Donottouchanyelectricalswitch;• Donotuseanyphoneinyourbuilding.• Immediatelycallyourgassupplierfromaneighbor'sphone.

Followthegassupplier'sinstructions.• Ifyoucannotreachyourgassupplier,callthefiredepart-

ment.

C.Useonlyyourhandtopushinorturnthegascontrolknob.Neverusetools.Iftheknobwillnotpushinorturnbyhand,don'ttrytorepairit;callaqualifiedservicetechnician.Forceorattemptedrepairmayresultinafireorexplosion.

D.Donotusethisapplianceifanyparthasbeenunderwater.Immediatelycallaqualifiedservicetechniciantoinspecttheappliance and to replace any part of the control system and anygascontrolwhichhasbeenunderwater.

LIGHTING INSTRUCTIONS

1. Set REMOTE/OFF/ON switch to OFF.2. Turnoffallelectricpowertotheapplianceifserviceistobe

performed(ifapplicable).3. Lowerbottomlouverassembly.

4. Pushingascontrolknobslightlyandturnclockwise to "OFF." Do not force.

5. Closebottomlouverassembly.

INTERMITTENT PILOT LIGHTING INSTRUCTIONS

OFF ON

GAS COCKPILOT ELECTRODE

FLAMESENSOR

Page 32: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 32

Flamesfromthepilot(rearrightbacksideofthepanburner)aswellasthemainflameshouldbevisuallycheckedasthelogsetis installed.Innormaloperationat fullrateafter10to15minutes,theflameappearanceshouldbesetsofyellowflames.NOTICE:Allflameswillberandombydesign,flameheightwillgoup and down.Glowingembers(rockwool)cancoverthepanburnerinbetweenthefrontandmiddlelogs,butverylittleisnecessarytocoverthisarea.Excessembermaterialcausestheyellowflametobecomeorangeandstringy.Applyjustenoughtoobtainslowglowandagoldyellowflame.Avoidanydraftsthatalterburnerflamepatterns.Donotallowfanstoblowdirectlyintofireplace.Donotplaceablowerinsidetheburnerareaofthefirebox.Ceilingfansmaycreatedraftsthatalterflamepatterns.Sootingandimproperburningwillresult.Duringmanufacturing,fabricatingandshipping,variouscomponentsofthisappliancearetreatedwithcertainoils,filmsorbondingagents.Thesechemicalsarenotharmful,butmayproduceannoyingsmokeandsmellsastheyareburnedoffduringtheinitialoperationoftheappliance,possiblycausingheadachesoreyeorlungirritation.Thisis a normal and temporary occurrence.Theinitialbreak-inoperationshouldlast2-3hourswiththeburnerat thehighest setting.Providemaximumventilationby openingwindows or doors to allow odors to dissipate. Any odors remaining after this initial break-inwill be slight andwill disappear withcontinued use.

PERIODIC CLEANING – Refer to parts diagram for location of items discussed below.• Donotusecleaningfluidtocleanlogsoranypartofheater.• Logs - brushwith soft bristle brush or vacuumwith brush

attachment.• Remove loose particles and dust from the burner areas,

controls,piezocoversandgrate.Don’tremoveceramicmediafrominsideburnerbox.

• Inspectandcleanburnerairintakehole.Removelintorparticleswithbrush.Failuretokeepairintakeholecleanwillresultinsootingandpoorcombustion.

ANNUAL CLEANING/INSPECTION – Refer to parts diagram for location of items discussed below.• Inspectandcleanburnerairintakehole.Removelintorparticles

withvacuumorbrush.Failuretokeepairintakeholecleanwillresultinsootingandpoorcombustion.

• Inspectandcleanallburnerports.• InspectODSpilotforoperationandaccumulationoflintatair

intakeholes.• Verifyflamepatternandlogplacementforproperoperation.• Verifysmoothandresponsiveignitionofmainburner.• Checklevelofceramicmediainburner.Burnershouldbefull,

uptothelevelofopeningsinburnertop.

OPERATION INSTRUCTIONS/FLAME APPEARANCE

Page 33: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 33

Figures 28, 30 and 32 showa correct pilot flamepattern.Thecorrectflamewillbeblueandwillextendbeyondthethermocouple.Theflamewillsurroundthethermocouplejustbelowthetip.Aslightyellowflamemayoccurwherethepilotflameandmainburnerflamemeet. Figures 29, 31 and 33showanincorrectpilotflamepattern.Theincorrectpilotflameisnottouchingthethermocouple.Thiswillcause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

MILLIVOLT PILOTCorrect Pilot Flame Pattern

THERMOPILE PILOT

THERMOCOUPLE

(LPG)

THERMOCOUPLE

(NATURAL)

Figure 28

Incorrect Pilot Flame PatternTHERMOPILE PILOT

THERMOCOUPLE

(LPG)

THERMOCOUPLE

(NATURAL)

Figure 29

Ifpilotflamepatternisincorrect,asshowninFigure29• SeeTroubleshooting,page36.

HYDRAULIC THERMOSTAT PILOTCorrect Pilot Flame Pattern

Figure 30

Incorrect Pilot Flame Pattern

Figure 31

Ifpilotflamepatternisincorrect,asshowninFigure31• SeeTroubleshooting,page36.

PILOT FLAME CHARACTERISTICS

Page 34: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 34

PILOT FLAME CHARACTERISTICSINTERMITTANT PILOT

Correct Pilot Flame Pattern

PILOT

SENSOR

IGNITOR

Figure 32

Incorrect Pilot Flame Pattern

PILOT

SENSOR

IGNITOR

Figure 33

Ifpilotflamepatternisincorrect,asshowninFigure33.• SeeTroubleshooting,page39.

Cleaning and Pilot MaintenanceOxygen Depletion Sensor Pilot (Figures 34, 35 and 36)When the pilot has a large yellow tip flame, clean theOxygenDepletion Sensor as follows:

1. CleantheODSpilotbylooseningnutBfromthepilottubing.Whenthisprocedureisrequired,graspnutAwithanopenendwrench.

2. Blowairpressurethroughtheholesindicatedbythearrows.Thiswillblowoutforeignmaterialssuchasdust,lintandspiderwebs.TightennutBalsobygraspingnutA.

Millivolt PilotFigure 34

B A

Hydraulic Thermostat PilotFigure 35

AB

Intermittant PilotFigure 36

Warning: Never use needles, wires, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow.

Page 35: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 35

Labelallwirespriortodisconnectionwhenservicingcontrols. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.Millivolt thermopile is self powered, gas valve does notrequire110volts.Maximumlengthof20feetof16AWG to conductorwires is to beusedwith alloptional switches.Usethetwoleads(RedandGreen)toattachoptionalcomponents.Check 750 Millivolt System OperationMillivoltsystemandallindividualcomponentsmaybecheckedwithamillivoltmeter0-1000MVrange.Remote ReceiverUse the following steps to place the remote receiver adjacent to the gas valve.Attention:Theremotereceiverbracketisnotusedin this installation.1. Theremotereceivercannotbeplacedbehind

thegasvalveandburnerassembly.2. When facing the appliance, the remote receiver

mustbeplacedtotherightofthegasvalve.Install remote control receiver behind bottomlouver.Refer to remote control installation and operating instructions for more details on remote control.

Keepthecontrolcompartment,logsandburnerareasurroundingthelogscleanbyvacuumingorbrushingareaatleasttwiceayear.THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.Alwaysturnoffgastothepilotbeforecleaning.Forrelighting,referto lighting instructions located on the rating plate of the log set.

Neverobstructtheflowofthecombustionandventilationair.Keepthefrontofthefireplaceclearofallobstaclesandmaterials.Leaveatleast36"clearancefromthefrontofthefireplace.Screenshouldbeclosedduringoperation.

Figure 37

REMOTE/OFF/ON SWITCH

A DISTANCE/FERME/OUVERT

INTERRUPTEUR

IF ANY OF THE ORIGINAL WIRE

AS SUPPLIED WITH THIS UNIT

MUST BE REPLACED, IT MUST BE

REPLACED WITH NUMBER 18, 150°C

WIRE OR ITS EQUIVALENT.

SI UN DES FILS ELECTRIQUES

ORIGINAUX, VENANT DU FABRICANT

AVEC CETTE UNITE, DOIT ETRE

REMPLACE, VOUS DEVEZ LE

REMPLACER AVEC UN FIL

ELECTRIQUE DE NUMERO 18,

150 ° C DU L'EQUIVALENT.

THERMOPILE

GAS VALVE

THERMOCOUPLE(NATURAL)

OFF

ON

REMOTE

(OPTIONAL) REMOTE CONTROL RECEIVER

(FACULTATIVE) CONTROLE E DISTANCE

DU RECEPTEUR

(OPTIONAL) WALL SWITCH

INTERRUPTEUR MURAL

(FACULTATIVE)

(OPTIONAL) THERMOSTAT

(FACULATIVE) THERMOSTAT

WIRING DIAGRAM

GAS VALVE

VALVE DE GAZ

REMOTE/OFF/ON SWITCH

A DISTANCE/OUVERT/

FERME INTERRUPTEUR

REMOTE CONTROL RECEIVER/

THERMOSTAT/ CONTROLE E

DISTANCE DU RECEPTEUR

H N

VEILLEUSEPILOT

THERMOCOUPLE(LPG)

WIRING

MAINTENANCE

Page 36: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 36

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.

1. When ignitor button is pressed, there is no spark at ODS/pilot. a. Ignitor electrode positioned wrong - Replace pilot.b. Ignitorelectrodeisbroken-Replacepilot.c. Ignitorelectrodenotconnectedtoignitorcable-Reconnect

ignitorcable.d. Ignitorcablepinchedorwet.Keepignitorcabledry-Free

ignitorcableifpinchedbyanymetalortubing.e. Brokenignitorcable-Replaceignitorcable.f. Bad piezo ignitor - Replace piezo ignitor.

2. Appliance produces unwanted odors.a. Applianceburningvapors frompaint,hair spray,glues,

etc. - Ventilate room. Stop using odor causing products while heater is running.

b. Gasleak-Locateandcorrectallleaks.3. Appliance shuts off during use. (Pilot and main burner are

off.)a. NotenoughfreshairisavailableforODS/pilottooperate

- Open window and/or door for ventilation.b. Lowlinepressure-Contactlocalgascompany.c. ODS/pilot is partially clogged - Clean ODS/pilot.d. Defective thermocouple - Replace pilot.

4. Appliance shuts off during use. (Pilot stays on.)a. Lowlinepressure-Checklinepressuretothevalve.b. Defective thermopile - Check pilot flame, check wire

connections,outputshouldbeaminimumof325millivoltsacross. TH/TP and TP terminals with ON/OFF switch off.

5. Gas odor even when control knob is in OFF position.a. Gasleak-Locateandcorrectallleaks.b. Controlvalvedefective-Replacecontrolvalve.

6. When ignitor button is pressed, there is spark at ODS/pilot, but no ignition.a. Gas supply turned off or manual shutoff valve closed - Turn

on gas supply or open manual shutoff valve.b. ControlknobnotinPILOTposition-Turncontrolknobto

PILOT position.c. ControlknobnotpressedinwhileinPILOTposition-Press

incontrolknobwhileinPILOTposition.d. Air in gas lines when installed - Continue holding down

control knob. Repeat igniting operation until air isremoved.

e. ODS/pilotisclogged-ReplaceODS/pilotassemblyorgetit serviced.

f. Gas regulator setting is not correct - Replace gas regulator.

7. ODS/pilot lights but flame goes out when control knob is released.a. Controlknobnotfullypressedin-Pressincontrolknob

fully.b. Controlknobnotpressedinlongenough-AfterODS/pilot

lights,keepcontrolknobpressedin30seconds.c. Manual Shutoff valve not fully open - Fully open manual

shutoff valve.

d. Thermocouple connection loose at control valve - Hand tighten until snug, then tighten 1/4 turn more.

e. Pilot flame not touching thermocouple, which allowsthermocoupletocool,causingpilotflametogoout.Thisproblemcouldbecausedbyeitherlowgaspressureordirty or partially clogged ODS/pilot - Contact local gas company.

f. Thermocouple damaged - Replace thermocouple.g. Control valve damaged - Replace control valve.

8. Burner does not light after ODS/pilot is lit.a. Burner orifice clogged - Clean burner or replacemain

burnerorifice.b. Burnerorificediameteristoosmall-Replaceburnerorifice.c. Inletgaspressure istoolow-Contactqualifiedservice

person. 9. If burning at main burner orifice occurs (a loud, roaring

blow torch noise).a. Youmustturnoffburnerassemblyandcontactaqualified

service person.b. Manifoldpressureistoolow-Contactlocalgascompany.c. Burnerorificeclogged-Cleanburnerorreplaceburner

orifice.10. Logs appear to smoke after initial operation.

a. Vaporsfrompaintorcuringprocessoflogs-Problemwillstop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for thefirstfewhours.

Logheaterisintendedtobesmokeless.TurnOFFheaterandcallqualifiedserviceperson.

11. Heater produces a whistling noise when main burner is lit.a. TurningcontrolknobtoHIGHpositionwhenmainburner

iscold-TurncontrolknobtoLOWpositionandletwarmup for a minute.

b. Airingasline-Operateburneruntilairisremovedfromline.Havegaslinecheckedbylocalgascompany.

c. Dirtyorpartiallycloggedburnerorifice-Cleanburnerorreplaceburnerorifice.

12. No gas to pilot.a. LP-regulator shut down due to inlet pressure too high

- Verify LP tank regulator is installed and set at 11" to 13" w.c. Replace regulator on heater.

TurnapplianceOFFandallowtocoolbeforeservicing.Onlyaqualifiedservicepersonshouldserviceandrepairtheheater.

TROUBLESHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS

Page 37: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 37

IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS5.25 VDC ELECTRONIC CONTROL VALVE

Theelectroniccontrolvalvesystemincludestheabilitytoswitchthe pilot from a standing pilot mode to an intermittent pilot mode.

• IPI Mode - In the Intermittent Pilot mode, when the unit is turnedON,itwillcausesparktothepilot,lightthepilot,thenallowtheburnertolight.WhentheunitisturnedtoOFF,boththeburnerandpilotwillbeOFF.

• CPI Mode - In the Continuous Pilot mode, the pilot re-mainsONcontinuouslyevenwhentheburneristurnedOFF.

Note:AsmalltoggleswitchislocatedonabracketthatisusedtoswitchfromIPI(upwardposition)totheCPI(downwardposition).See Figure 38.

When the unit is turned to ON, the electrical current will energize asparktothepilotigniter.Oncethepilotsensorheatsup(afterafewseconds),thevalvewillbeenergized,allowinggastoflowtotheburner.

1. Follow the SAFETY and LIGHTING INSTRUCTIONS for In-termittentPilotcontrols found in thismanual,andon labelsfound in the control compartment located in the lower cavity of the appliance.

2. Duringtheoperatingseason(orinpoweroutageperiods),itisrecommendedthatthepilotremainintheCPI(standingpilotmode) to reduce cold start issues, and/or conserve batterybackuppowerduringapoweroutage.

3. The gas valve has inlet and outlet pressure taps as shown in Figure38.Refertopage15forgaspressurerequirements.

Note: Thegascontrol hasamanualHI/LOflameadjustmentknob(regulator)thatallowsyoutoincreaseordecreasetheheightof theburnerflame.SeeFigure38. RotatetheHI/LOknobcounterclockwiseto“HI”toincreasetheflameheight,andclockwiseto“LO”todecreasetheflameheight.

OPTIONAL REMOTE CONTROLS Optionalremotecontrolsareavailableforusewiththisappliance.Toconnecttheremotereceivertotheappliance,firstdisconnectthe ON/OFF switch wires from the white and green wire connec-tors and connect the wires from the remote receiver to the green and white wire connectors. See Figure 38.Follow the instructions included with the remote control for pro-gramming and other operational information.

Figure 38

DFCELECTRONICCONTROLMODULE

REMOTECONTROLRECEIVER

AA (4)BATTERYBACKUP

IPI

CPI

PILOT SELECTOR SWITCH

IPI - INTERMITANT PILOT (UP)

CPI - CONTINUOUS PILOT (DOWN)

SPARK ROD

GROUND

9 PIN CONNECTOR

PILOTSENSOR

GAS VALVE

OUTLETPRESSURETAP

INLETPRESSURETAP

IGNITORSENSOR

PILOTASSEMBLY

Page 38: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 38

IPI ELECTRONIC SYSTEM WIRING DIAGRAM

Ifanyoftheoriginalwireassuppliedwiththisunitmustbereplaced,itmustbereplacedwithequivalentgaugeandtemperaturerated wire.

Thisapplianceisonlyforusewiththetypeofgasindicatedontheratingplateandmaybeinstalledinanaftermarket,permanentlylocated,manufactured(mobile)homewherenotprohibitedbylocalcodes.Thisapplianceisnotconvertibleforusewithothergases.

CAUTION:Donotoperatetheappliancewithpanel(s)removed,crackedorbroken.Replacementofthepanel(s)shouldbedonebyalicensedorqualifiedserviceperson.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss oflife.Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagencyorthegassupplier.

(GND)

PILOT

CPI/IPI

SWITCH

GAS CONTROL

VALVE

ELECTRONIC

CONTROL MODULE

BATTERY HOLDER

BATTERY

BACK-UP RED

BLACK

RED

BLACK

GREEN

WHITE

WHITEBLUE BLUE

WHITEORANGE

GREEN

YELLOW

BLACK

BLACK

AC/DC

POWER ADAPTOR

REMOTE RECEIVER

(OPTIONAL)

(

(

(

+ ON

REMOTE

- OFF

BLA

CK

WH

ITE

ON/OFF

SWITCHOR

Page 39: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 39

INTERMITTENT CONTROL SYSTEM TROUBLESHOOTINGBrief Description of the ComponentsThegasvalveisequippedwithamanualHI/LOknobtoallowformanual modulation of the gas outlet pressure. The manual HI/LO knob can be replaced by an EmpireComfort SystemsVariableRemoteKit.

WARNINGThis appliance is equipped for Natural or Propane gas. Field conversion is not permitted.

TheDigitalFireplaceControl (DFC) isanautomaticgas ignitionsystembasedonasinglemicrocontrollercore.Thiscontrolman-agesall functionsrelatedto ignition,flamesensingandsupervi-sion for atmospheric applications. TheDFCcanbesettoprovidecontinuousorintermittentignitioncontrolsequencesandflamemonitoringwithsafetyshutdownincase of failure.TheDFC is set up as a standalone (ACpowered systemwithbatterybackup.SeeLightingInstructionsonpage31andWiringDiagram on page 38.

TroubleshootingBefore proceedingwith the procedures in the following trouble-shooting table, verify that the power supply (AC/DCadapter) ispresentandthatthebatteriesinsidethereceiverand/oroptionalbatterypackarefreshandinstalledwithcorrectpolarity.Makesureall theconnectionsbetween thewireharnessesandsystem components are proper and positive.Verifythatthestaticinletpressuremeetsthemanufacturer’srec-ommended inlet pressure. If necessary adjust the line pressure regulator.Iftherecommendedactionsforthefollowingtroubleshootingchartdonothelptoaddresstheproblemconsiderreplacingwiringhar-nesses.

WARNING: Any actions performed on the gas valve must be performed in accordance with this instruction manual. Likewise, any actions performed on the DFC or other system components must be done in accordance with the individual component instructions. Replacement of components must be performed in accor-dance with this instructions manual.

Page 40: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 40

INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING1

If the DFC giving signal lock out:The board should be unlocked toreinitiate a pilot flame ignition (forthe correct unlock sequence referto the DFC Use and Installation

Instructions).

Is the DFC board inlock out?

1. Verify the electrical connections’ integrity andmake sure they are in accordance with the relevantsystem wiring diagram. If necessary replace thewire harness.

2. Replace the DFC board.

Was observed sparkat the Pilot Hoodbefore the DFC

board locked out?

1. Check the spark electrode positioning - adjustas necessary.

2. Replace the pilot assembly.

3. Verify the electrical connections’ integrity andmake sure they are in accordance with therelevant system wiring diagram. If necessaryreplace the wire harness.

4. Replace the DFC board.

1. Verify the electrical connections’ integrity andmake sure they are in accordance with therelevant system wiring diagram. If necessaryreplace the wire harness.

2. If pilot flow adjuster screw is not sealed:Check if pilot flow adjust screw is set correctly inaccordance with the appliance manufacturerinstructions. If necessary correct it.

3. Replace pilot tube or complete pilotassembly.

4. Replace the pilot orifice with a new orifice ofcorrect size, and type, or replace the pilotassembly. Under all circumstances follow theappliance manufacturer’s service instructions.

5. Remove the provided wiring harnesses fromEv1 of gas valve (red base), and verify voltage atignition between the Ev1 terminal and the groundconnection on teh valve body. If the voltage isgreater than 0 then Replace Valve. OtherwiseReplace DFC.

Spark continueswhile the pilot is ON.

2

1. Replace the pilot assembly.

2. Replace the DFC board.

NO NO

YES

NO

YES

YES

YES

NO

Page 41: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 41

INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING2

Main burner lightswhen the pilot only

should light.

Pilot holds the flame?.

Main burner ignites?

Main burner remainsON

1. Replace DFC board.

2. Replace the gas valve.

1. Verify the pilot flame fully engulfs the tip of the sense electrode. If not replace the pilotassembly.

2. Replace the pilot assembly.

3. Carefully clean the electrical connections of the sense cable, and the DFC board sensecable connection.

4. Replace the sense cable, or the cable-sense electrode assembly, or the pilot assembly.

5. Verify the pilot is properly grounded.

6. Replace the pilot orifice with a new orifice of correct size, and type, or replace the pilotassembly.

7. If pilot flow adjuster screw is not sealed, correct it.

1. Verify the electrical connections’ integrity and make sure they are in accordance with therelevant system wiring diagram. If necessary replace the wire harness.

2. Check if the optional remote transmitter is in “thermostat” or “on” mode and verifyt there is acall for heat (f using a thermostat remote). Adjust the setting for heat.

3. Verify that the pilot hood is properly fitted and a pilot flame is directed to properly ignite themain appliance burner.

4. Replace the main burner orifice with a new orifice of correct size and type, or replace thepilot assembly. Under all circumstances follow the service instructions.

5. Remove the provided wiring harnesses from EV2 of gas valve (red base), and verify voltageat ignition between the EV1 terminal and the ground connection on the valve body.5.1 If the voltage is greater than 0 then Replace Valve.5.2 Or Replace DFC.

6. Check the pressure at the outlet pressure test point out according to the manufacturer’sinstruction. If not in accordance, replace the gas valve.

1. Verify the electrical connections’ integrity and make sure they are in accordance with therelevant system wiring diagram. If necessary replace the wire harness.

2. Check the pressure at the outlet pressure test point out according the manufacturer’sinstruction. If not in accordance replace the gas valve.

3. With the system in the OFF position, connect the voltmeter between the EV2 terminal(green base) on the valve, and the ground on the valve body.Turn the system ON, let pilot light, and observe the following voltage sequence: once the pilotflame is proved, the voltage on EV2 should spike to approx. 5 VdC for approx. 2 sec and thendrop to approx. 0.6 VdC continuously.3.1 If the sequence is respected, replace the gas valve.3.2 If the sequence is not respected, replace the DFC board.

YES

YES

YES

NO

NO

NO

NO

Main burnermodulatesproperly?

1. Replace the main burner orifice with a new orifice of correct size (partial blockage possible).Verify that the main burner flame modulates. If it does not modulate replace the gas valve.

2. Verify that the gas valve outlet pressure limits are in accordance with the manufacturerspecifications. If not replace the gas valve.

3. Verify the flame changes while rotating the HI/LO knob on the front of the gas valve. If thereis no change replace the gas valve.

FOR MANUAL HI/LO VERSION

Page 42: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 42

INDEX NO.

PART NO. DESCRIPTION

COMMON PARTS1 28061 FIREBOX UPPER BAFFLE2 26157 FIREBOX BAFFLE3 21642 BRICKLINERBRACKET4 R9192 BRICKPANEL,BACK5 R9195 BRICKPANEL,RIGHTSIDE6 R9194 BRICKPANEL,LEFTSIDE7 R10434 BRICKPANEL,BACKLEG8 26494 REAR LOG SUPPORT9 P253 FITTING, ORIFICE ANGLED11 R5676 AIRSHUTTER(NATONLY)

11 R5675 AIR SHUTTER-FULLY OPEN (LPGONLY)

12 12347 BURNERSUB-ASSEMBLY(NAT)12 12348 BURNERSUB-ASSEMBLY(LPG)13 26498 GRATETANGBRACKETASSEMBLY14 23329 LOUVER ASSEMBLY15 26496 FRONT FRAME ASSEMBLY16 26162 PIEZOBRACKET17 R9760 IGNITOR, PIEZO25 R2423 CONNECTOR, MALE27 26161 VALVEBRACKET35 R7591 FLEXLINE 3/8" X 12

36 24925 BLOWER SUB-ASSEMBLY (W/MOUNTINGPLATE,PAD)

37 18879 RHEOSTAT ASSEMBLY (SPEEDCONTROL)

38 33411 SWITCH ASSEMBLY39 R2204 CORD SET40 R7912 WIRE HARNESS, FAN CONTROL

VFP20IN23L10 P265 ORIFICE #42 - NAT10 P182 ORIFICE #53 - LPG29 R5171 PILOT, NAT29 R5170 PILOT, LPG30 R2479 REGULATOR,6.0W.C.(NAT)30 R2480 REGULATOR,10.0W.C.(LPG)31 P239 NIPPLE, 3/8 NPT X 1 1/232 23487 VALVE ASSEMBLY - NAT32 27007 VALVE ASSEMBLY - LPG33 27003 TUBINGASSEMBLY-PILOT(NAT)33 27506 TUBINGASSEMBLY-PILOT(LP)34 26707 TUBING ASSEMBLY - INLET

VFP20IN33L and VFP20IN33L1010 P181 ORIFICE#43-NAT(20,000BTU)10 P182 ORIFICE#55-LPG(20,000BTU)10 P214 ORIFICE#53-NAT(10,000BTU)10 P193 ORIFICE#64-LPG(10,000BTU)18 R3436 SWITCH, REMOTE OFF/ON19 R3624 PILOT, NAT19 R3623 PILOT, LPG20 R3626 VALVE,NAT(20,000BTU)20 R3625 VALVE,LPG(20,000BTU)20 R9368 VALVE,NAT(10,000BTU)20 R9369 VALVE,LPG(10,000BTU)21 26167 TUBINGASSEMBLY-PILOT(LPG)

22 26171 TUBING ASSEMBLY - REGULATOR TO VALVE(NAT)

23 R7063 PILOTREGULATOR(NAT)

24 27732 TUBING ASSEMBLY - REGULATORTOPILOT(NAT)

26 26708 TUBING ASSEMBLY - INLET28 R10947 WIRE ASSEMBLY

VFP20IN73L and VFP20IN73L1041 R11126 VALVE - LP41 R11125 VALVE - NAT41 R11210 VALVE-NAT(10,000BTU)41 R11211 VALVE-LP(10,000BTU)42 R11327 PILOT ASSEMBLY - LP42 R11328 PILOT ASSEMBLY - NAT43 29376 PILOTBRACKET44 29377 VALVEBRACKET45 R2522 ON/OFF SWITCH46 29903 SWITCHBRACKET47 29813 INLET TUBING ASSEMBLY

48 33809 TUBING ASSEMBLY REGULATOR TO PILOT - NAT

49 29816 PILOT TUBING ASSEMBLY REGULATOR TO VALVE - NAT

50 33810 TUBING ASSEMBLY - LP51 R11332 24" SENSOR WIRE52 R11333 24" IGNITOR WIRE53 R11127 DFC CONTROL BOARD54 R2667 5-1/2"BLACKWIRE(QTY2)55 R11122 BATTERY HOLDER56 R11123 WIRE HARNESS57 R11128 7.0 VDC AC ADAPTER58 30379 SHIELD, PILOT

INDEX NO.

PART NO. DESCRIPTION

VFP20IN PARTS LIST

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Page 43: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 43

3

9

14

4

23

6

1

8

10

11

12 13

15

MILLIVOLT

VALVE ASSEMBLY

HYDRAULIC

VALVE ASSEMBLY

40

37

38

36

7

14

39

16

INTERMITTENT PILOT (IP)

VALVE ASSEMBLY

5

7

17

18

19

20

21

22

23

24

25

26

27

27

25

1617

29

3031

32

33

34

35

28

54

53

56

55

42

43

41

46

45

57

5047

48

52

51

44

49

23

58

VFP20IN PARTS VIEW

Page 44: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 44

VFP28IN PARTS LIST

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

INDEX NO.

PART NO. DESCRIPTION

COMMON PARTS1 28053 FIREBOX UPPER BAFFLE2 26157 FIREBOX BAFFLE3 21642 BRICKLINERBRACKET4 R9196 BRICKPANEL,BACK5 R9198 BRICKPANEL,RIGHTSIDE6 R9197 BRICKPANEL,LEFTSIDE7 R10434 BRICK,PANELBACKLEG9 11833 PILOTSHIELD(NATONLY)

10 P253 FITTING, ORIFICE ANGLED12 R5676 AIRSHUTTER(NATONLY)

12 R5675 AIR SHUTTER - FULLY OPEN (LPGONLY)

13 18838 BURNER ASSEMBLY WITHOUT AIR SHUTTER

14 23694 AIR SHUTTER SHIELD15 26160 BURNER BASE - REAR16 30379 PILOT SHIELD 17 26159 BURNER BASE - FRONT18 26162 PIEZOBRACKET19 R9760 PIEZO IGNITOR20 R7591 FLEXLINE 3/8" X 12" LONG21 17169 LOUVER ASSEMBLY22 26163 FRONT FRAME ASSEMBLY23 26161 VALVEBRACKET26 R2423 CONNECTOR, MALE

39 24925 BLOWER SUB-ASSEMBLY (WITHMOUNTINGPLATE,PAD)

40 18879 RHEOSTAT ASSEMBLY (SPEEDCONTROL)

41 33411 SWITCH ASSEMBLY42 R2204 CORD SET43 R7912 WIRE HARNESS, FAN CONTROL

VFP28IN238 R5171 PILOT, NAT8 R5170 PILOT, LPG11 P286 ORIFICE#42(NAT)11 P214 ORIFICE#53(LPG)33 R2479 6.0W.C.REGULATOR(NAT)33 R2480 10.0W.C.REGULATOR(LPG)34 P239 3/8" NPT x 1 1/2" NIPPLE35 11923 VALVEASSEMBLY(NAT)35 11924 VALVEASSEMBLY(LPG)36 26168 PILOTTUBINGASSEMBLY(LPG)37 26166 INLET TUBING ASSEMBLY

38 26170 PILOTTUBINGASSEMBLY(NAT)VFP28IN33

8 R3624 PILOT(NAT)8 R3623 PILOT(LPG)11 P203 ORIFICE#38(NAT)11 P185 ORIFICE#52(LPG)24 R3626 VALVE(NAT)24 R3625 VALVE(LPG)25 R3436 REMOTE/OFF/ON SWITCH27 26165 INLET TUBING ASSEMBLY28 26167 PILOTTUBINGASSEMBLY(LPG)

29 26169 REGULATOR TO PILOT TUBING ASSEMBLY(NAT)

30 R7063 PILOTREGULATOR(NAT)

31 26171 REGULATOR TO VALVE TUBING ASSEMBLY(NAT)

32 R10947 WIRE ASSEMBLY

VFP28IN73L

44 R11126 VALVE - LP

44 R11125 VALVE - NAT

45 R11327 PILOT ASSEMBLY - LP

45 R11328 PILOT ASSEMBLY - NAT

46 29376 PILOTBRACKET

47 29377 VALVEBRACKET

48 R2522 ON/OFF SWITCH

49 29903 SWITCHBRACKET

50 29817 INLET TUBING ASSEMBLY

51 29820 TUBING ASSEMBLY REGULATOR TO PILOT - NAT

52 29819 PILOT TUBING ASSEMBLY REGULATOR TO VALVE- NAT

53 33812 TUBING ASSEMBLY - LP

54 R11332 24" SENSOR WIRE

55 R11333 24" IGNITOR WIRE

56 R11127 DFC CONTROL BOARD

57 R2667 5-1/2"BLACKWIRE(QTY2)

58 R11122 BATTERY HOLDER

59 R11123 WIRE HARNESS

60 R11128 7.0 VDC AC ADAPTER

61 30379 SHIELD, PILOT

NS 31273 PILOT FLAME SHIELD

INDEX NO.

PART NO. DESCRIPTION

Page 45: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 45

5

3

4

6

3

1

2

7

8

910

11

12

1314

15

16

17

18

22

24

23

2526

27

28

29

19

20

3132

33

34

35

36

30

37

MILLIVOLT

VALVE ASSEMBLY

HYDRAULIC

VALVE ASSEMBLY

38

43

40

41

39

7

21

21

23

26

42

INTERMITTENT PILOT (IP)

VALVE ASSEMBLY

57

56

59

58

45

46

44

49

48

60

5350

51

55

54

47

5230

61

VFP28IN PARTS VIEW

Page 46: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 46

ATTENTION: When ordering parts, it is very important that part number and description of part coincide.

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

1

2

3

4

Index No.

Part No. Description

VFP28IN LOG SET1 R8301 REAR LOG2 R8299 LEFT FRONT LOG3 R8300 RIGHT FRONT LOG4 R8302 Y BRANCH

LOGS PARTS LISTS & PARTS VIEWS

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

3

21

Index No.

Part No. DESCRIPTION

VFP20IN LOG SET1 R7504 LEFT FRONT LOG2 R7505 RIGHT FRONT LOG3 R7506 BACKLOG

ATTENTION: When ordering parts, it is very important that part number and description of part coincide.

Page 47: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 47

To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com.Toprovidewarrantyservice,yourdealerwillneedyournameandaddress,purchasedateandserialnumber,andthenatureoftheproblemwiththeunit.ToOrderPartsAftertheWarrantyPeriod,pleasecontactyourdealeroroneoftheMasterPartsDistributorslistedbelow.Thislistchangesfromtimetotime.Forthecurrentlist,pleaseclickontheMasterPartsbuttonatwww.empirecomfort.com.Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered OriginalEquipmentrepairpartsforHeaters,Grills,andFireplacesmanufacturedbyEmpireComfortSystemsInc.

MASTER PARTS DISTRIBUTOR LIST

Dey Distributing1401WillowLakeBoulevardVadnais Heights, MN 55101

Phone: 651-490-9191Toll Free: 800-397-1339Website:www.deydistributing.comParts: Heater, Hearth and Grills

F. W. Webb Company200 Locust StreetHartford, CT 06114

Phone: 860-722-2433Toll Free: 800-243-9360Fax: 860-293-0479Toll Free Fax: 800-274-2004Websites: www.fwwebb.com&www.victormfg.comParts: Heater, Hearth and Grills

East Coast Energy Products10 East Route 36West Long Branch, NJ 07764

Phone: 732-870-8809Toll Free: 800-755-8809Fax: 732-870-8811Website: www.eastcoastenergy.comParts: Heater, Hearth and Grills

Parts Not Under WarrantyPartscanbeorderedthroughyourServicePerson,Dealer,oraMasterPartsDistributor.SeethispagefortheMasterPartsDistribu-torslist.Forbestresults,theservice person or dealershouldorderpartsthroughthedistributor.Partscanbeshippeddirectlytotheservice person/dealer.Warranty PartsWarrantypartswillneedaproofofpurchaseandcanbeorderedbyyourServicePersonorDealer.Proofofpurchaseisrequired for warranty parts.AllpartslistedinthePartsListhaveaPartNumber.Whenorderingparts,firstobtaintheModelNumberandSerialNumberfromthenameplateonyourequipment.ThendeterminethePartNumber(nottheIndexNumber)andtheDescriptionofeachpartfromthefol-lowing illustration and part list. Be sure to give all this information . . .

ApplianceModelNumber Part Description

ApplianceSerialNumber PartNumber

TypeofGas(PropaneorNatural)

Donotorderbolts,screws,washersornuts.Theyarestandardhardwareitemsandcanbepurchasedatanylocalhardwarestore.Shipmentscontingentuponstrikes,firesandallcausesbeyondourcontrol.

HOW TO ORDER REPAIR PARTS

Page 48: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 48

Decorative Mission Louver Decorative Leaf LouverDecorative Arch Louver

STD Louvers 45 Deg

STD SurroundCast Iron Traditional Surround

Bottom Cover

STD Surround

STD Shroud

DECORATIVE ACCESSORIESThefollowingaccessorypartscanbeobtainedfromyourEmpireComfortSystemsdealer.Ifyouneedadditionalinformationbeyondwhatyourdealercanfurnish,contactEmpireComfortSystemsInc.,NineEighteenFreeburgAve.,Belleville,Illinois62220.

• Black• GoldFinish• HammeredPewter• BrushedStainless

• Black• GoldFinish• HammeredPewter• BrushedStainless

• Black• GoldFinish• HammeredPewter• BrushedStainless

• Black • Black • Black

• Black • Black(Standard)• GoldFinish• HammeredPewter• BrushedStainless

• BlackUsed to finish off bottom of in-sert and surround panels when installed in a fireplace without aflush hearth extension. Can beused with traditional cast iron or contemporarysurroundkits.

Page 49: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 49

Louvers 45 DegGlass Door Frame

Bottom Cover

6x6 Surround

SurroundShroud

Insert Accessories

SURROUND FRONTSThisfireplacerequiresasurround,availablefromyourEmpireComfortSystemsdealer.Thesurroundshownbelowallowsthefireplacetobeinstalledasaninsertinanexistingfireplaceorinamantel.Forelevatedinstallationinawall,seethesurroundsonthefollowingpage.Ifyouneedadditionalinformationbeyondwhatyourdealercanfurnish,contactEmpireComfortSystemsInc.,NineEighteenFreeburgAve.,Belleville,Illinois62220.

•Black •Black(Standard)

•HammeredPewter•Stainless

•BlackThe shroud provides a transition from thefireplace/inserttoyourexistinghearth opening up to 48 x 36 inches. Requiresasurround.

•Black •BlackUsedtofinishoffbottomofinsertandsur-roundpanelswheninstalledinafireplacewithoutaflushhearthextension.Tobeusedwithsurroundkits.

Page 50: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 50

GLASS FRONT34"x201/2"glasspanelwithmountingbrackets,shieldand

hardware.

Glass Front

Trim

Bottom Shield

METAL PICTURE FRAME371/2"x231/2"withglasspanel(concealedlouversontop)

Thefireplacerequiresasurround,availablefromyourEmpireComfortSystemsdealer.TheDF20GBLandDF20MBLsurroundsshownbelowallowthefireplacetobeinstalledelevatedinawall.Forinstallationasaninsertinanexistingfireplaceorinamantel,seetheDF20LBL on the previous page.

SURROUND FRONTS

Page 51: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017 Page 51

WARRANTY TERMSEmpireComfortSystemsInc.warrantiesthishearthproducttobefreefromdefectsatthetimeofpurchaseandfortheperiodsspeci-fiedbelow.Hearthproductsmustbeinstalledbyaqualifiedtechnicianandmustbemaintainedandoperatedsafely,inaccordancewiththeinstructionsintheowner’smanual.Thiswarrantyappliestotheoriginalpurchaseronlyandisnottransferable.Allwarrantyrepairsmustbeaccomplishedbyaqualifiedgasappliancetechnician.

Limited Lifetime Parts Warranty with a Five-Year Limited Labor Warranty – Combustion Chamber and Heat Exchanger Ifthecombustionchamberorheatexchanger(seepartslist)failsbecauseofdefectiveworkmanshipormaterial,Empirewill repairorreplaceatEmpire’soption.Withinfiveyearsfromthedateofpurchase,Empirewillpayreasonablelabortohavethe defectivepartrepairedorreplacedatEmpire’soption.

Limited Five-Year Parts & Labor Warranty – All Other Components (Except Remote Controls, Thermostats, Accessories and Replacement Parts) Shouldanypartfailbecauseofdefectiveworkmanshipormaterialwithinfiveyearsfromthedateofpurchase,Empirewill repairorreplaceatEmpire’soption.Withinfiveyearsfromthedateofpurchase,Empirewillpayreasonablelabortohavethat defectrepairedatEmpire’soption.

Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts Shouldanyremotecontrol,thermostat,accessory,orotherpartfailbecauseofdefectiveworkmanshipwithinoneyearfrom thedateofpurchase,EmpirewillrepairorreplaceatEmpire’soption.

Duties Of The Owner Theappliancemustbeinstalledbyaqualifiedinstallerandoperatedinaccordancewiththeinstructionsfurnishedwiththe appliance.Abillofsale,cancelledcheck,orpaymentrecordshouldbekepttoverifypurchasedateandestablishwarranty period. Ready access to the appliance for service.

What Is Not Covered Damages that might result from the use, misuse, or improper installation of this appliance. Travel, diagnostic costs and freight charges on warranted parts to and from the factory. Claimsthatdonotinvolvedefectiveworkmanshipormaterials. Unauthorized service or parts replacements. Removal and reinstallation cost. Inoperableduetoimproperorlackofmaintenance.

How To Get Service Tomakeaclaimunderthiswarranty,pleasehaveyourreceiptavailableandcontactyourinstallingdealer.Providethedealer withthemodelnumber,serialnumber,typeofgas,andpurchaseverification.Theinstallingdealerisresponsibleforproviding serviceandwillcontactthefactorytoinitiateanywarrantedpartsreplacements.Empirewillmakereplacementpartsavailable atthefactory.Shippingexpensesarenotcovered.If,aftercontactingyourEmpiredealer,servicereceivedhasnotbeen satisfactory, contact: Consumer Relations Department, Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, [email protected]“ConsumerRelations”inthesubjectline.

Your Rights Under State Law Thiswarrantygivesyourspecificlegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate.

Page 52: INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL · home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This

29829-19-1017Page 52

www.empirecomfort.com

Empire Comfort Systems Inc.Belleville, ILIfyouhaveageneralquestionaboutourproducts,pleasee-mailus at [email protected]. If you have a service or repair question,pleasecontactyourdealer.