Improving the Efficiency of Your Ozone System By Alison Trollier May 5, 2010

Upload: others

Post on 24-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Improving the Efficiency of Your

Ozone System

By Alison Trollier

May 5, 2010

Page 2: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Agenda•Ozone – Review•Contacting & Mass Transfer•Evolution of Ozone Contacting•Venturi Injector Sizing•Maximizing Transfer Efficiency•Benefits of Transfer Efficiency

Page 3: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

•Strongest disinfectant•Improves water clarity•No hazardous chemical handling•No disinfection by-products•No added TDS•Rapid decay to Oxygen

Ozone

Introduction Method is Key to System Efficiency

Page 4: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Ozone System EfficiencyEffective ozone disinfection requires CT:

•Transfer efficiency

•Good mixing

•Adequate Contact time

•Minimal short circuiting in contactor

Contacting

Contact Time

Page 5: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Contacting – what does this word mean?

•Driving the gas into solution•Not just bubbles-in, bubbles-out

•Ozone as a gas – does not disinfect

•Gas not dissolved is wasted

•Gas-to-liquid transfer (mass transfer)

•Happens only at the gas-liquid interfacial exposure

Page 6: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Bubbles•Def: a globule of one substance encased in another, usually gas in a liquid

Gas-liquid interface -where all transfer occurs

Gas inside the bubble-this gas is wasted unless the bubble is sheared to renew the gas-liquid interface

Page 7: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Gas to Liquid TransferTransfer happens only at the gas-liquid interface

(surface area of bubbles)

•Micro-bubbles – Good•High surface area per volume

•Large Bubbles – Bad •Low surface area per volume

Page 8: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Mass Transfer Principles

Four Factors affect mass transfer efficiency:

•Ozone Gas Concentration

•Gas-to-liquid Volume Ratio

•Mixing Pressure – Henry’s Law

•Mixing Velocity – Renewal of gas/liquid interface

Page 9: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Venturi Injectors

Demonstrates the Bernoulli Principle –

“Where there is higher velocity, there is lower pressure…”

Page 10: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Venturi InjectorsWith booster pump With Pressure Reducer

Outlet/Downstream Pressure (PSI)Motive Force (GPM)Inlet Pressure (PSI)

Ozone Gas (SCFH)

Page 11: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Injector Performance Tables

Outlet Pressure (Must be >20 PSI)

MotiveForce?& Inlet Pressure? Ozone Gas

(NEED 64 SCFH)

Find: Motive Force (GPM)Required Inlet Pressure (PSI)Injector Model Number

54.1 GPM required, at 45 PSI to get 73.7 SCFH of gas suction

Outlet/Downstream Pressure must be >20 PSI to overcomeline pressure

Use Injector Model 1584

Page 12: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Evolution of Ozone Contacting

Fine Bubble Diffusion

1980’s

Lower Gas/Liquid RatioHigher Mixing VelocityHigher Mixing Pressure

Venturi Injector with Large Contact/Degas Vessel

Page 13: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Evolution of Ozone Contacting

PressurizedContacting & Degassing

1995

Higher Mixing VelocityHigher Mixing PressureEntrained Gas Removal

Venturi Injector with Large Contact/Degas Vessel

Page 14: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Evolution of Ozone Contacting

PressurizedContacting & Degassing

Secondary Mixing

Higher mixing velocityHigher mixing pressure

Page 15: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Evolution of Ozone Contacting

Page 16: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Maximize Your Transfer Efficiency

• Interfacial exposure renewal•Re-shear bubbles

•High Mixing Velocity

•High Ozone Gas Concentration

•High Mixing Pressure

•Low Gas-to-liquid Volume Ratio

Page 17: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Maximize Transfer EfficiencyOzone TE Vs Pressure

(TE Vs G/L)

0.010.0

20.030.0

40.050.0

60.070.0

80.090.0

100.0

1 10 20 30 40

Injector/Nozzle Outlet PSIG

% T

rans

fer E

ff

0.06 0.10 0.14

G/L = 0.06

G/L = 0.10

G/L = 0.14

G/L = ft3 gas ft3 water

Page 18: Improving the Efficiency of Your Ozone System...Ozone Gas (NEED 64 SCFH) Find: Motive Force (GPM) Required Inlet Pressure (PSI) Injector Model Number 54.1 GPM required, at 45 PSI to

Benefits of High MTE•More efficient use of ozone

•Smaller gen or extra capacity

•Less pump horsepower

Benefits of New Technology•Smaller footprint

•No need to re-pressurize

•Safety

•Ease of maintenance