improvements of the hydrological processes of the town
TRANSCRIPT
1
Improvements of the hydrological processes of the Town Energy
Balance Model (TEB-Veg, SURFEX v7.3) for urban modelling and
impact assessment
Xenia Stavropulos-Laffaille1, Katia Chancibault1, Jean-Marc Brun1, Aude Lemonsu2, Valery Masson2,
Aaron Boone2, HervΓ© Andrieu1 5
1IFSTTAR, GERS, EE, F-44344 Bouguenais, France 2CNRM UMR 3589, MΓ©tΓ©o-France/CNRS, Toulouse, 31057 Toulouse CEDEX 1, France
Correspondence to: Xenia Stavropulos-Laffaille ([email protected])
Abstract. Climate change and demographic pressure are common issues to be considered when conducting urban planning.
Local authorities and stakeholders have therefore opted for more nature-based adaptation strategies, which are especially 10
suitable to influence both hydrological and energy processes. Assessing the multiple benefits of such strategies on the urban
microclimate thus requires effective numerical tools. This paper presents recent developments of the water budget in the
TEB-Veg model (SURFEX v7.3), which allows for a better representation of the hydrological processes of urban subsoil.
This new hydrological module has been called TEB-Hydro. The developments studied concern the introduction of subsoil
underneath built surfaces, and the processes of: horizontally rebalancing intra-mesh soil moisture, draining soil water via the 15
sewer network, and limiting deep drainage in the aim of achieving a more realistic base flow pattern in the sewer system. A
sensitivity analysis is then performed in order to identify the hydrological parameters required for model calibration. The
new TEB-Hydro model is evaluated on two small residential catchments in Nantes (France) by comparing simulated sewer
discharges to observation findings. In both cases, the model tends to overestimate total sewer discharge and performs better
under wet climate conditions, with a KGE statistical criterion greater than 0.80 vs. roughly 0.60 under drier weather 20
conditions. Yet these findings remain encouraging since the same set of model parameters are identified for both catchments,
irrespective of meteorological and local physical conditions. This approach opens opportunities to apply the model at the city
scale with respect to projections of climate and demographic changes.
1. Introduction
Urbanisation is the predominant trend in today's world. Cities consume space and energy, generate pollution and nuisances, 25
and are vulnerable to natural or manmade hazards, such as floods and urban heat islands (hereafter denoted UHI), that
climate change is likely to exacerbate (EEA, 2012).
The adaptation of cities to global changes (climate change and demographic pressures) has become a major challenge in the
field of planning policy. The use of nature-based solutions (hereafter NBSs), such as green and blue infrastructure, has been
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
2
approved as part of sustainable urban development (Sustainable Urban Drainage Systems, water and pollution source
control, insulation of buildings) and is therefore recommended (Hamel et al., 2013; EC, 2015). However, evaluating such
adaptation and mitigation strategies requires conducting impact studies capable of assessing the various services these
solutions can offer along with their interactions (energy, thermal comfort, water, landscaping, etc.) (Bach et al., 2014). As
regards hydro-microclimatic patterns, the processes of evapotranspiration (or latent heat flux) constitute an increasingly 5
significant portion of both the urban water and energy budgets. For modelling purposes, evapotranspiration is thus a key
element since it affects the water and energy budgets (Mitchell et al., 2008).
Despite the increased interest in urban hydrology over recent years (Fletcher et al., 2013; Hamel et al., 2013; Shirmer et al.,
2013; Salvadore et al., 2015), the various water- and energy-related processes are still rarely addressed with the same level
of detail, and the coupling between them is often oversimplified. 10
In the past, the emphasis on the urban water cycle was directed at the design of urban drainage systems and their operations
under extreme events (flooding, low water level). Hydraulic models have thus been used to analyse rainfall-runoff patterns
during rain events when evapotranspiration is not a major concern (Berthier et al., 2006; Fletcher et al., 2013). In recent
decades however, a more decentralized urban water management system has necessitated impact studies that focus on the
urban water cycle as a whole. Consequently, urban hydrological models are being more heavily promoted, even though they 15
still simplify or neglect the energy balance. Evapotranspiration is therefore often calculated from a reference value of
potential evapotranspiration, which takes into account soil moisture conditions and sometimes vegetation (Rodriguez et al.,
2008; Rossman, 2010; DHI, 2001). At the local level, atmospheric demand is typically not considered a limiting factor for
evapotranspiration, and a direct interaction rarely exists between the water balance and the energy balance. In their state-of-
the-art paper, Fletcher et al. (2013) noted that evapotranspiration in urban areas remains relatively poorly explored. 20
Unlike hydrological models, the urban micro-climate models (Masson, 2000; Musy et al., 2015; Gros et al., 2016) provide a
detailed solution of energy and radiative budgets, while the water balance has been simplified, which can lead to an
alteration of the modelled latent heat fluxes (Grimmond et al., 2011). Malys et al. (2016) used such a model to evaluate the
mitigation effects of vegetation on UHI. Soil moisture however is not considered as a limiting factor, hence potentially
leading to an overestimation of the cooling abilities of plants, especially under hot climate conditions. For example, the 25
Town Energy Balance Scheme (TEB) described by Masson (2000) is a mesoscale surface scheme dedicated to the urban
environment. The urban environment is presented in a simplified manner by means of the street canyon approach (Oke,
1987), which averages the characteristics of urban covers and morphology (building height, construction materials, canyon
aspect ratio, street orientation) inside one grid mesh. This approach initially resolves detailed energy and radiative budgets of
built-up areas (buildings and roads), while the hydrological part is presented more simply, i.e.: i) artificial surfaces (buildings 30
and roads) are completely impervious; and ii) water exchanges are thus only taken into account between the surface and the
atmosphere. Lemonsu et al. (2007) then introduced the rainfall interception capacities of built-up surfaces and integrated
water infiltration through artificial surfaces, like roads, pavements and parking lots, into TEB in order to implement more
realistic hydrological processes. Using the ISBA-DF model (Interaction Soil-Biosphere-Atmosphere - explicit vertical
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
3
diffusion) (Boone et al., 2000) as part of the urban fabric, by integrating vegetated surfaces inside the street canyon, the TEB
model has evolved into TEB-Veg (Lemonsu et al., 2012). Interactions within the radiative, energy and water balances
between natural and artificial surfaces are now considered. Nevertheless, even if a detailed water balance for the subsoil of
natural surfaces is calculated, the water processes occurring in the subsoil of artificial surfaces and their interactions with the
surface are still neglected. 5
The objective of this study is to develop a complete urban hydro-microclimate model, hereafter called TEB-Hydro, by
integrating the subsoil under built-up surfaces and hydrological soil-surface interactions into the existing TEB-Veg model.
This step will allow treating the energy and water budgets at the same level of detail, which is critical to the impact
assessment of NBSs at a city scale. First, the model concept will be described. Since the energy and radiation components of
the model have not changed, as fully described in Masson (2000) and Lemonsu et al. (2012), the focus is placed on the 10
model's hydrological component and recent model developments. Next, the experimental sites and observation data will be
presented. The model evaluation will then be laid out in Section 4 in analysing the simulations performed by the new model
version.
2. Description of the TEB-Hydro hydrological model
TEB-Hydro is an evolution of TEB-Veg, with SURFEX v7.3 (Lemonsu et al., 2012), and was developed on the SURFEX 15
modelling platform (Masson et al., 2013). Like TEB-Veg, TEB-Hydro is based on a regular grid mesh and can be run either
coupled with other meteorological models or in offline mode forced by observed atmospheric data. It combines two surface
schemes, TEB (Masson, 2000) and ISBA-DF (Boone et al., 2000), both of which run on an integrated tiling approach and
describe energy and water exchanges between the urban and natural subsoils, the surface and atmosphere, respectively. The
urban environment is represented by three compartments, such as buildings (roofs and walls), roads (streets, pavements and 20
parking), and gardens. This section will present the new model developments based on the existing TEB-Veg model version.
A general description of the hydrological processes will be laid out first, followed by a discussion of the new developments
dedicated to hydrological processes in the urban subsoil (Fig. 1).
2.1 General principles of hydrological processes
Interactions between the energy balance (Eq. 1) and water balance (Eq. 2) are established via the explicit resolution of the 25
evapotranspiration term (Eq. 3):
πβ + ππΉ = ππ» + ππΈ + βππ + βππ΄ [π πβ2] (1)
π + πΌ = πΈ + π + π· + βπ [ππ πβ2 π β1] (2)
ππΈ =πΈ
πΏπ [π πβ2] (3)
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
4
where πβ is the net all-wave radiation, ππΉ the anthropogenic heat flux, ππ» the sensible heat flux, ππΈ the latent heat flux, βππ
the heat flux storage, βππ΄ the net advection heat flux, π the total precipitation, πΌ the water generated from anthropogenic
activities (irrigation), πΈ the evapotranspiration, π the total runoff, π· the deep drainage, βπ the variation in water storage
both on the surface and in the ground during the simulation period, and lastly πΏπ£ the latent heat of vaporisation (-).
2.1.1 Evapotranspiration 5
The evaporation is calculated for each surface type πΈβ (Fig. 1). For built-up surfaces, this value depends on both the surface
specific humidity at saturation and the air humidity (inside the canyon for roads and above the canopy level for roofs)
(Masson, 2000). Limitations are set by the maximum surface retention capacity of roofs ππππ₯,πππ π’ππ
and roads ππππ₯,πππ π’ππ
, as
represented by the surface water reservoirs. For natural surfaces, the various contributions from vegetation and natural
subsoil are considered (Eq. 4) (Lemonsu et al., 2012): 10
πΈπππ = πΈπ£ππ + πΈππ + πΈππ,π + πΈπ (4)
where Eveg is the vegetation evapotranspiration, Egr,i and Egr the evaporation from bare soil respectively with and without
freezing, and Es the sublimation from snow.
2.1.2 Water interception
The water content evolution in the interception water reservoirs of each surface type (denoted πβπ π’ππ
) is affected by 15
precipitation and evapotranspiration rates, as indicated in Masson (2000) and Lemonsu et al. (2012):
ππβπ π’ππ
ππ‘= π β
πΈβ
πΏπ£ (5)
where * stands for rooftops, vegetation or bare ground surfaces.
For the road interception reservoir, the original evolution equation has been modified by including a slight water infiltration
rate (πΌππ) (m s-1), since roads are never totally impervious (Ramier et al., 2011): 20
πππππ π’ππ
ππ‘= π β
πΈππ
πΏπ£β πΌππ (6)
πΌππ is defined as a constant value over which the model must be calibrated.
2.1.3 Surface runoff
According to Masson (2000), when πβπ π’ππ
(mm) exceeds the maximum reservoir capacity (ππππ₯,βπ π’ππ
), surface runoff is
produced (π βπ π’ππ
). Henceforth, it is collected by stormwater or combined sewer networks, depending on the connected 25
effective impervious areas fraction (ππππ) (Sutherland, 2000). Surface runoff not collected by the sewer system ((π πππ π’ππ
+
π πππ π’ππ
) β (1 β ππππ)) is then added to the throughfall over natural surfaces, where it can infiltrate into the subsoil with a
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
5
maximum infiltration capacity, according to the Green-Ampt approach (Abramopoulos et al., 1988; Entekhabi and Eagleson,
1989; Lemonsu et al., 2012).
The urban runoff π π‘ππ€π (mm s-1), which is used to determine the total sewer discharge (ππ‘ππ€ππ‘ππ‘ ), is composed of several
sources:
π π‘ππ€π = π πππ π’ππ
β ππππ + π πππ π’ππ
β ππππ + π π ππ€ + π βπ π’ππ π’ππ
(7) 5
where π πππ π’ππ
β ππππ and π πππ π’ππ
β ππππ are respectively the roof and the road surface runoff connected to the sewer network
(mm s-1); π π ππ€ is the runoff in the sewer network due to soil water infiltration (mm s-1), and π βπ π’ππ π’ππ
the subsurface runoff
from each compartment (mm s-1) calculated in Eq. 16.
2.1.4 Vertical water transfer
The surface water infiltration, as described above, constitutes an input to the subsoil of both the garden compartment and 10
road compartment. The water is then transferred vertically (ππ£) from layer to layer, accounting for the liquid water transfer
and water vapour transfer stated in Boone et al. (2000). This process depends solely on pressure gradients, which enables
taking different hydraulic soil properties into consideration. At the bottom of each soil column, the vertical water transfer is
adapted by taking boundary conditions into account. The resulting outgoing water flux of the model is called deep drainage
π·β, which has been slightly modified for TEB-Hydro (Sect. 2.2.3). 15
2.2 Inclusion of hydrological processes in the urban subsoil
In accordance with the soil description of urban gardens provided in Lemonsu et al. (2012), soil compartments are now
considered under built-up surfaces such as roads and buildings. All three soil columns are represented by horizontal layers,
with an identical vertical grid in order to compute subsurface soil water transport. The thickness of each layer increases 20
downward, with a higher grid resolution on top. In the case of the road compartment, the upper soil layers are represented by
structural layers in accordance with Bouilloud et al. (2009). By integrating natural soil below urban surfaces, the
hydrological processes in the soil (vertical water transfer and deep drainage) of both road and building compartments are
being adapted from the garden compartment. Water infiltration through the road structure is thus now considered as a
recharge of soil moisture in the road compartment soil column. No water however is input into the building compartment soil 25
column.
2.2.1 Horizontal water transfer
The lateral water interactions of each soil layer among the three distinct compartments of a same grid cell have been added.
In considering the structural layers of the road compartment, the horizontal transfer in the upper soil layers is computed
solely between the garden and building compartments. Below there, all three compartments are accounted for. 30
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
6
This approach is based on the principle of an exponential decay of the water content, tending towards the mean soil moisture
of all three compartments, which is limited by soil moisture content at the wilting point. In assuming that the soil texture is
identical in each grid cell compartment and moreover that no lateral transfer is taking place between the various grid cells of
the model, the lateral intra-mesh soil moisture transfer for each soil layer is described as follows:
ππβππ
ππ‘= β
1
πβ
πΎπ ππ‘Μ Μ Μ Μ Μ Μ Μ
πΎπ (8) 5
Updating the soil moisture content in each layer and compartment after each time step yields:
πβππ,β²
= πππΜ Μ Μ Μ Μ Μ + (πβππ
β πππΜ Μ Μ Μ Μ Μ ) β ππ₯π(β (1
πβ
πΎπ ππ‘Μ Μ Μ Μ Μ Μ Μ
πΎπ) β ππ‘) (9)
with: πππΜ Μ Μ Μ Μ Μ =β πβ
ππβπβ
β πβ (10)
where πβππ
and πβππ,β²
are respectively the soil moisture content for each compartment before and after horizontal balancing
(m3 m-3), πππΜ Μ Μ Μ Μ Μ the mean soil moisture content of all compartments before balancing (m3 m-3), π the time constant of one day, 10
πΎπ ππ‘Μ Μ Μ Μ Μ Μ Μ
πΎπ the ratio of the mean hydraulic conductivity at saturation of all three compartments to the hydraulic conductivity of each
compartment, ππ‘ the numerical time step of the model(s), and πβ the fraction of each compartment.
2.2.2 Drainage of soil water by the sewer network
Various experiments and observations (Belhadj et al., 1995; Lerner, 2002; Berthier et al., 2004; Le Delliou et al., 2009) have
shown that soil water drainage occurs when artificial networks are situated under saturated soil moisture conditions. 15
However, the ISBA soil pattern is intended to depict the unsaturated zone rather than the saturated zone. This pattern is
based on a representation of the soil moisture state in agronomic terms (i.e. water content at wilting point, field capacity and
saturation). When taking this into account, the infiltration rate into the sewer network (πΌπ ππ€ ππ m s-1) is described in such a
way that the hydraulic conductivity of the network soil layer (ππ ππ€(πππ) (m s-1)) is its limiting factor, with a maximum value
at saturation of: 20
πΌπ ππ€ = ππ ππ€(πππ) β πΌπ β π·π ππ€ (11)
where πΌπ is a calibration parameter, without any physical significance, representing the water tightness of the sewer pipe (-),
and π·π ππ€ the sewer density within a single grid cell (-) expressed by the ratio of the total sewer length in one grid cell (m) to
the maximum total sewer length in a single grid cell of the entire study site (m). Let's note that this formulation has been
adapted to TEB-Hydro from Rodriguez et al. (2008). 25
2.2.3 Deep drainage
In cities, artificial networks may play the role of rivers and thus contribute to draining soil water by means of infiltration. It
has therefore been envisaged to limit deep drainage in order to favour soil water infiltration into the sewer networks during
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
7
wet periods. For this purpose, the soil moisture emerging from the last layer of the model is partially or totally retained,
according to a coefficient πΆπππβ, until complete layer saturation. At each time step, the soil moisture content in the last layer
n is thus updated according to:
πβππ,π
= πβππ,π
+ πβππ,πππ’π₯,π
β πΆπππβ (12)
And the deep drainage becomes: π·β = πβππ,πππ’π₯,π
β (1 β πΆπππβ) β ππ β π/ππ‘ (13) 5
where πβ ππ,π
is the soil moisture content of the last layer n (m3 m-3), πβππ,πππ’π₯,π
the soil moisture content derived from the
outgoing water flux (m3 m-3), πΆπππβ the coefficient of retention (-), π·β the deep drainage (mm s-1), ππ the thickness of the last
layer, π the water density (kg m-3), and dt the numerical time step of the model(s).
If the deep layer is saturated, the excess moisture rises from layer to layer, with:
The soil moisture content in upper layer i-1: πβππ,πβ1,β²
= πβ ππ,πβ1
+ max(0 , πβππ,π
β πβ,π ππ‘ππ,π
) βππβ1
ππ (14) 10
The soil moisture content remaining in layer i: πβππ,π,β²
= min( πβππ,π
, πβ,π ππ‘ππ,π
) (15)
If saturation reaches the surface layer, then the excess moisture is added to subsurface runoff:
π βπ π’ππ π’ππ,β²
= π βπ π’ππ π’ππ
+ max(0 , πβππ,1
β πβ,π ππ‘ππ,1
) βπ1
ππ‘β π (16)
where πβ,π ππ‘ππ,π
is the soil moisture content at saturation (m3 m-3), πβππ,π,β²
and πβ ππ,π
respectively the soil moisture content in 15
current layer i, after and before update (m3 m-3), πβππ,πβ1,β²
and πβ ππ,πβ1
respectively the soil moisture content in upper soil
layer i-1, after and before update (m3 m-3), ππβ1
ππ (-) the ratio of layer thicknesses between upper layer i-1 and lower layer i,
and π βπ π’ππ π’ππ,β²
and π βπ π’ππ π’ππ
respectively the subsurface runoff after and before update (mm s-1).
2.3 TEB-Hydro output variables
In addition to the simulated hydrological output variables calculated in TEB-Veg (latent heat fluxes on all surfaces, soil 20
moisture in each soil layer (ππππππ,π
) and deep drainage (π·πππ) of the garden compartment), the TEB-Hydro model simulates
the soil moisture in each soil layer (πβππ,π
) and the deep drainage (π·β) under artificial surfaces. Other new model output
variables include urban runoff (π π‘ππ€π ), with its components stemming from rooftops (π πππ π’ππ
β ππππ ) and road surfaces
(π πππ π’ππ
β ππππ), soil water infiltration into the sewer network (π π ππ€ ), and the subsurface runoff from each compartment
(π βπ π’ππ π’ππ
). 25
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
8
3. Experimental study areas and observation data
The experimental data are derived from two small urban catchments in the city of Nantes (France). The properties of these
catchments, along with local observation data and the meteorological forcing data of the model will be described below.
3.1 Experimental data
3.1.1 RezΓ© catchment 5
The RezΓ© experimental site is located in the southern part of the city of Nantes, close to the Atlantic coast (Fig. 2). It was
instrumented (with measurements of precipitation, discharge from the rainwater network and soil water) from 1993 to 1998,
and a complete continuous database is available for that period. The climate is oceanic with an average annual rainfall of
approx. 830 mm during this period; the year 1994 was the wettest one.
The 4.7-ha basin is entirely residential, comprising single-family homes with private gardens. The separate sewer network is 10
divided into wastewater and stormwater with lengths of 803 m and 480 m, respectively. The impervious surface of the
catchment accounts for 45% of the total area, of which 84% is connected to the stormwater system. A detailed site
description can be found in Berthier et al. (1999) and Dupont et al. (2006) (Tab. 1).
The RezΓ© catchment and its database have been the subject of several studies (Rodriguez et al., 2003; Berthier et al., 2004;
Dupont et al. (2006); Lemonsu et al., 2007; Rodriguez et al., 2008). Berthier (1999) modelled the role of soil in generating 15
urban runoff on the RezΓ© catchment. He studied both the hydrological aspects and site observations. Among other emphases,
he examined the discharge observed in the wastewater sewer during the winter periods between 1993 and 1997 before
estimating the discharge due to soil water infiltration and compared this value with the simulated base flow in the sewer
network.
3.1.2 Pin Sec catchment 20
The Pin Sec experimental site is located in the eastern section of Nantes; it has been a part of the Nantes Observatory for the
Urban Environment (ONEVU) since 2006 and thus contains a dense network of continuous measurement equipment (rain
gauges, flow meters in networks, piezometers, tensiometers and micro-climatological masts). In correspondence with the
simulation period of this study, rainfall patterns were analysed between May 2010 and September 2012, with an annual
rainfall of approx. 700 mm for the year 2011. 25
The catchment area spans 31 ha with some 2,500 inhabitants (Le Delliou et al., 2009). The northern part of the site is
characterised by single-family housing with private gardens, unlike the southern part, which encompasses 4-storey multi-
family buildings with public parks (Fig. 2b). The sewer network is separate, divided into wastewater and stormwater with
respective lengths of 6,973 m and 3,911 m. 51% of the total area is impervious, of which only 61% has been found (survey
conducted by the Nantes Metropolitan government) to be connected to the stormwater sewer. A description of this catchment 30
is summarised in Tab. 1.
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
9
3.2 Meteorological forcing
Forcing the model with observations requires atmospheric data, such as precipitation, temperature, specific humidity,
atmospheric pressure, wind speed and direction, and incoming shortwave and longwave radiation. For both experimental
sites, the precipitation rates (no snowfall for all simulation periods) were collected on site by means of rain gauges.
All other forcing data were generated from the data of the nearby MΓ©tΓ©o-France weather station (at Nantes Airport), 5
including incoming solar radiation, cloudiness, pressure, air temperature and humidity at 2 m above ground, and wind speed
at 10 m above ground. To avoid the direct influence of the urban canopy, the forcing level height for temperature, humidity
and wind had to be set above the roughness sublayer top, hence the atmospheric data had to be adjusted accordingly
(Lemonsu et al., 2012).
4. Evaluation of the TEB-Hydro model 10
The TEB-Hydro model was evaluated by comparing the simulated with the observed total sewer discharge and the portion of
this discharge due to soil water infiltration. Observations were derived from the two experimental sites described above.
Let's note that the local properties of these sites, as well as the simulation period, do vary. A sensitivity analysis performed
on the RezΓ© catchment will be presented first. The hydrological parameters taken into account consist of: the maximum
retention capacity of the artificial surfaces ππππ₯,βπ π’ππ
(roads and buildings), a parameter describing the water-tightness of the 15
sewer pipe πΌπ , the maximum infiltration rate through the road structure πΌππ , the fraction of impervious surface areas
connected to the sewer network ππππ, and the deep drainage π·β (Sect. 2 and Tab. 2). In addition, possible combined effects of
these studied parameters will also be analysed. As is typical with hydrological models, the model is calibrated on those
parameters where it shows the greatest sensitivity. Next, the model will be evaluated on the observed total sewer discharge
of both the RezΓ© and Pin Sec catchments. Simulations will be run with the TEB-Hydro model and then compared to 20
observations in order to discuss the performance of recent model developments.
4.1 Model configuration
The TEB-Hydro model (SURFEX v7.3) has been applied to a single grid point (1D) for both experimental sites; it operates
in "off-line" mode, forced by meteorological observations (Sect. 3.2), with a one-hour time step. The model's numerical time
step is 5 min. For both catchments, 12 soil layers were taken into account, and the road structure was divided into 5 artificial 25
layers. By virtue of the mean sewer system depth (1.50 m), the sewer pipe is thus situated in the 10th soil layer. Natural
surfaces are represented by bare ground, low and high-growth vegetation.
In the case of the RezΓ© catchment, the model was run over a 6-year period, from January 1993 to December 1998. The
hydrological year starts in September, as the lowest base flow can be detected in August for the Nantes region. Its
morphological data, radiative and thermal properties of the materials (TEB), and soil and vegetation properties (ISBA) have 30
all been considered, like in Lemonsu et al. (2007).
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
10
The simulation period for the Pin Sec catchment is 2.5 years, i.e. between May 2010 and September 2012. The
morphological site data, radiative and thermal properties of the materials (TEB), and soil and vegetation properties (ISBA)
were determined on the basis of several sources (FluxSAP database (Furusho, 2012), Nantes Metropolitan urban databank,
and Ecoclimap I (Faroux et al., 2013)). Due to inconsistencies between previous studies (Le Delliou et al., 2009; Seveno et
al., 2014), the Pin Sec catchment area has been re-delimited using a GIS (Fig. 2b). 5
4.2 Sensitivity analysis
The sensitivity analysis was solely conducted on the RezΓ© catchment; its aim was to better understand the role of each
individual parameter on the various hydrological processes and identify those responsible for greater model sensitivity and
thus requiring calibration. In general, two types of analyses were conducted: local and global (Saltelli et al., 2004; Tang et
al., 2006). For this study, a local analysis based on the One Factor at a Time (OFAT) method was chosen (Montgomery, 10
2017). This approach measures the influence of a parameter by the amplitude in variation of the model's response around a
nominal value of this parameter. The sensitivity analysis encompasses several hydrological parameters, with a range of
realistic values (minimum, nominal, maximum). These values have been identified from either a literature review or in situ
measurements (Berthier et al., 1999; Lemonsu et al., 2007; Furusho et al., 2013) (Tab. 2). The REF simulation is based on
the nominal values of all parameters. The MIN and MAX simulations can consistently be performed when a single 15
parameter is changed respectively to its minimum and maximum values, while the other parameters remain fixed at their
nominal values.
Moreover, a two-level factorial plan of 23 is presented in order to determine whether or not some parameters (Ip, Ird and Dβ)
display combined effects on the model output and then dissemble the interactions taking place between them. Such a design
is of common use in experiments involving several interlinked factors (Montgomery, 2007). 20
Each parameter is assigned two levels, which serves to limit the experimental domain. In the current case, the domain of
each parameter corresponds to the margins set for the sensitivity analysis. The higher level will hereafter be denoted +1 for
the MAX parameter value and -1 for the lower value corresponding to the parameter MIN value (Tab. 3). To take all
possible parameter combinations into account, a matrix is generated with all values being arranged according to the "Yates
Order". The principal effects (Eq. 17) of the given parameters and the effects of their interactions (Eq. 18) are then 25
calculated, in direct correlation with the mean response of both its low level (οΏ½Μ οΏ½ββ) and high level (οΏ½Μ οΏ½β+). The dependence of
two parameters can be analysed visually by showing the effects of both parameters on the model response (yΜ β): two perfect
parallel lines would not indicate any interdependence between the two factors, as opposed to non-parallelism.
In the current context, οΏ½Μ οΏ½β corresponds to the maximum observed sewer discharge due to soil water infiltration Qsew,max
during winter 1994/95 in the RezΓ© catchment. A positive effect stands for an increase of this process while transitioning from 30
the low parameter level (-1) (MIN value) to its high value (+1) (MAX value), and vice versa in the case of a negative effect:
π(π΄) = οΏ½Μ οΏ½π΄+ β οΏ½Μ οΏ½π΄β (17)
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
11
π(π΄π΅) = οΏ½Μ οΏ½π΄π΅+ β οΏ½Μ οΏ½π΄π΅β (18)
where π(π΄) is the principal effect of a parameter called π΄ , π(π΄π΅) the effect of the interaction between two different
parameters π΄ and π΅, οΏ½Μ οΏ½β+ the mean response of all combinations where the parameter or the interaction of two parameters is
at its high level (+1), and οΏ½Μ οΏ½ββ the mean response of all combinations where the parameter or the interaction of two
parameters is at its low level (-1). 5
4.3 Comparative method
In the case of the sensitivity analysis, the Kling-Gupta statistical criterion (KGE) has been calculated from the output
variables of the MIN or MAX simulations as Dsim(t), and from the output variables of the REF simulation as Dref(t) (Eqs. 19
to 22). For the model calibration and evaluation phase, Dref(t) is replaced by observed data Dobsf(t). The Kling-Gupta
efficiency (KGE) coefficient is a synthesis of several criteria varying between 1 and -β (Gupta et al., 2009): 10
πΎπΊπΈ = 1 β β(π β 1)2 + (πΌ β 1)2 + (π½ β 1)2 (19)
With the linear correlation coefficient (r):
π =β((π·π ππ(π‘)βπ·π ππΜ Μ Μ Μ Μ Μ Μ Μ )β(π·πππ(π‘)βπ·πππΜ Μ Μ Μ Μ Μ Μ ))
ββ(π·π ππ(π‘)βπ·π ππ)Μ Μ Μ Μ Μ Μ Μ Μ Μ 2βββ(π·πππ(π‘)βπ·πππ)Μ Μ Μ Μ Μ Μ Μ Μ Μ 2 (20)
With the relative variability (Ξ±) represented by the standard deviation:
πΌ =ββ(π·π ππ(π‘)βπ·π ππ)Μ Μ Μ Μ Μ Μ Μ Μ Μ 2
ββ(π·πππ(π‘)βπ·πππ)Μ Μ Μ Μ Μ Μ Μ Μ Μ 2 (21) 15
And the bias (Ξ²):
π½ =π·π ππΜ Μ Μ Μ Μ Μ Μ Μ
π·πππΜ Μ Μ Μ Μ Μ Μ (22)
The results of the Kling-Gupta efficiency (KGE) criteria are then presented for each MIN and MAX simulation. For this
analysis, the chosen model output variables depend on the influence of the parameter on the hydrological processes, namely:
Urban runoff (π π‘ππ€π) and the subsequent total urban discharge (wastewater and stormwater sewer) (ππ‘ππ€ππ‘ππ‘ ); 20
Soil water drainage via the sewer network (π π ππ€).
4.4 Calibration
Based on the outcomes of the sensitivity analysis, the model is then calibrated. The first few months of the spin-up
simulation period are systematically excluded in order to anticipate problems upon initialising the model's prognostic
variables. Calibration is applied transversally, meaning that after removing the spin-up time from the simulation period, it is 25
split into two equal periods, and the model is calibrated and evaluated on both of them. By doing so, the model will first be
calibrated on the first period and then evaluated on the second in following the same process by inversing calibration and
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
12
evaluation periods. The simulations are then compared with the observed total sewer discharge and, like for the sensitivity
analysis (Sect. 4.3), the KGE criterion is calculated along with its components.
5. Results and discussion
5.1 Sensitivity analysis
As shown in Tab. 4, the KGE coefficients for both the MIN and MAX simulations specific to maximum retention capacity of 5
the surface reservoir of roads (Wmax,rdsurf ) and roofs (Wmax,rf
surf ) show little difference for both the urban runoff and runoff due to
soil water infiltration (Figs. 3a and 3b). In the case of maximum roof retention capacity, urban runoff is mainly influenced by
small rainfall events.
In terms of urban runoff, the model does not show any higher sensitivity to the parameter describing the infiltration rate
through the road (Ird) than to Wmax,rdsurf and Wmax,rf
surf (Tab. 4). Such is not the case however when considering the sewer runoff 10
due to soil water infiltration. As the road infiltration rate increases, total surface runoff decreases but only for small rain
events (Fig. 4a). Also, soil moisture rises within the soil layers, thus boosting soil water infiltration into the sewer network
(Fig. 4b).
As expected, the model is more sensitive to the fraction of impervious surfaces connected to the sewer system (ππππ) (Fig. 5).
The bias (Ξ²) and relative variability (Ξ±) (Tab. 4) reveal different values for MIN and MAX simulations, yet they both lead to 15
the same KGE criterion (Tab. 4). The variation in the fcon parameter influences urban runoff as well as sewer runoff due to
soil water infiltration. A low connection rate leads to a lower urban runoff, while a greater parameter value increases urban
runoff (Fig. 5). The runoff from surfaces not connected to the sewer system feeds the infiltration towards the natural
surfaces. The amount of infiltrated water in the garden compartment thus changes with this parameter, thereby influencing
the soil moisture in all layers and compartments. These values are higher when the fraction of connected surfaces is low and, 20
conversely, lower with a high fraction.
The calculated KGE values (Tab. 4) are quite divergent between the MIN and MAX simulations for parameters πΌπ and π·β
with both output variables, which implies that the model is very sensitive to them. In addition, the results of the factorial plan
(Fig. 6), based on the calculated direct effects on the maximum sewer discharge due to soil water infiltration, corroborate
these results. 25
As for the parameter describing the water-tightness of the sewer pipe (Ip), its increase leads to higher peaks of infiltration
into the sewer network (Fig. 7a) but does not influence the infiltration period. Moreover, the calculated effect of an πΌπ of
+2.9E-04 signifies an increase in soil water infiltration into the sewer network when transitioning from its low level (-1) to
its high one (+1) (Fig. 6). In fact, soil water drainage via the sewer network is as important as a degraded network condition
(cracks, root penetration, etc.), and soil moisture at the network location is close to saturation. 30
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
13
As for the deep drainage parameter (π·β), the negative effect (Fig. 6) indicates that infiltration declines with an increasing
parameter value. As seen in Fig. 7b, limiting deep drainage to a magnitude of 10% (MAX) does not generate a significant
difference with the reference simulation in assessing sewer discharge due to soil water infiltration. Blocking the deep
drainage completely (MIN) however leads to a saturation of the lower soil layers, thus adding to the soil water infiltration
into the sewer network (Fig. 7b). 5
As was the case for water-tightness of the sewer pipe (πΌπ), both the infiltration rate through the road (πΌππ) and deep drainage
(π·β) seem to influence the sewer drainage due to soil water infiltration, with the effects of their interactions having been
calculated and visualised. In this manner, the πΌπ/π·β interaction can be highlighted as the most influential of all three first-
order interactions (Fig. 6). In addition, Figure 8 effectively shows the correlation between the two parameters (see the two
lines run non-parallel to one another), whereas the correlations between the other parameters appear to be less significant. 10
In comparing model sensitivity among the 6 parameters for both urban runoff and runoff due to soil water infiltration, it can
be concluded that the model is less sensitive to changes in parameters Wmax,rdsurf and Wmax,rf
surf . Four parameters can thus be
singled out for calibration:
The parameter describing the water-tightness of the sewer pipe (πΌπ)
Infiltration rate through the road (πΌππ) 15
The fraction of impervious surfaces connected to the sewer network (ππππ)
Deep drainage (π·β).
5.2 Model calibration and evaluation
In considering the results of the sensitivity analysis, this model needs to be calibrated on four parameters. Yet for both
catchment areas, the parameter ππππ has been determined during exhaustive field surveys and therefore is well known. 20
Consequently, this parameter will be neglected, hence only the three remaining parameters are considered for calibration.
Four different values within the predefined range of the sensitivity analysis are tested for each parameter (Tab. 5). The model
is calibrated and evaluated on the total observed sewer discharge (ππ‘ππ€ππ‘ππ‘ ), as determined from the model outcome variable:
urban runoff (π π‘ππ€π). However, since the drainage capacity of soil water through the sewer network can be extensive in
urban areas, the share of sewer discharge originating from soil water infiltration (ππ ππ€) has been investigated in detail. 25
Hence, the choice of this parameter's values also depends on the findings of the sensitivity analysis with respect to this
output variable (ππ ππ€). In Section 5.1, it was shown that soil water infiltration into the sewer increases as the πΌπ value rises,
as opposed to parameters πΌππ and π·β. The range of values has thus been set close to the maximum πΌπ value and minimum πΌππ
and π·β values. Totally blocking the deep drainage however is not an option, since in reality soil water is not only drained by
artificial sewer systems but moreover can find other pathways within the urban subsoil (groundwater recharge, seepage, 30
etc.).
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
14
5.2.1 RezΓ© catchment
In the RezΓ© catchment, the calibration and evaluation periods have been compounded by two consecutive hydrological years,
i.e. from September 1993 to August 1995, and from September 1995 to August 1997.
The KGE criterion results indicate a clear and constant trend for all simulations, independently of the considered time period
(Fig. 9) or the value of parameter Dβ: 5
For starters, as seen in the example (deep drainage limited to 2%), all KGE criteria are far better for the first period from
1993 to 1995 than for the second (1995-97) (Fig. 9). This discrepancy between the two simulation periods is primarily
related to the KGE criterion component bias (Ξ²), which shows a greater bias for the second simulation period (Fig. 9).
Secondly, the smallest value of Ip achieves a better result than the highest value, when assessing total sewer discharge.
Thirdly, the parameter Ird does not exert significant influence on the simulated total sewer discharge, since the criterion does 10
not vary much among its different values.
The correlation (r) of simulated and observed discharge peaks is satisfactory, with values of about 0.90 for both simulation
periods and all simulation configurations (Fig. 9). The model displays a tendency to overestimate the observed total sewer
discharge (Fig. 10), more so for the second simulation period, showing greater variability (Ξ±) through all simulations (Fig. 9).
Regardless of the deep drainage values, simulation 13 seems to stand out with a KGE between 0.79 and 0.82 over the entire 15
simulation period. The KGE values range between 0.81 and 0.84 for the first period and between 0.66 and 0.68 for the
second. In examining both simulation periods separately, simulation 14 seems to perform slightly better for the first period.
Given the fact that simulation 13 performs much better over the second period than simulation 14, simulation 13 should also
be tagged for a transversal calibration. The degradation in KGE during the second year is mainly related to the higher bias
values, most likely caused by the various hydrological properties of both simulation periods. For the first period 1993-95, a 20
total precipitation height of approx. 1,873 mm with a very wet winter during 1994-95 can be observed, whereas the second
period is much dryer posting just 1,302 mm.
As regards total sewer discharge, the best combination of parameters would be to set parameter Ip at 0.09 and Ird at 10-5,
whereas parameter Dβ can vary. We will thus be examining in greater detail the portion of sewer discharge due to soil water
infiltration, with parameter Dβ influencing this process significantly. Berthier (1999) observed a maximum sewer discharge 25
due to soil water infiltration of about 0.008 m3 h-1 lm-1 during the winter 1994-95. Accounting for the total sewer length of
1,283 m at the RezΓ© catchment would yield a maximum sewer infiltration rate of roughly 10.3 m3 h-1. Limiting deep drainage
to 2% produces (Fig. 11a) a simulated discharge peak of 4.8 m3 h-1 during this period, which is much less than observation
findings. In looking at the simulation with a limited deep drainage (Dβ) of 1%, the observed discharge peak becomes
significantly overestimated at 27 m3 h-1 (Fig. 11b). In the aim of evaluating the model as well on the sewer discharge due to 30
soil water infiltration, deep drainage should be limited somewhere between 1% and 2%.
Another option would consist of focusing on the Ip parameter since the sensitivity analysis also revealed its influence on the
process of soil water infiltration into the sewer. As stated above, raising the value of Ip is beneficial for the infiltration rate.
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
15
Hence, simulation 14 would be more suitable, as Ip has been set at 0.3 while Ird remains at 10-5. In conjunction with deep
drainage limited to 2%, the maximum sewer discharge due to soil water infiltration during winter 1994-95 equals roughly
10.6 m3 h-1, which is close to the observed discharge (Fig. 11c). For this combination of parameters (i.e. Ip =0.3, Ird=10-5,
Dβ=2), the KGE criterion based on total sewer discharge is slightly better, like for simulation 13, with a value of 0.86 for the
first period. Such is not the case however for the second period, with a value of 0.57. 5
5.2.2 Pin Sec catchment
For the Pin Sec catchment, the period between September 2010 and August 2011 has been compared to the period from
September 2011 to August 2012 and vice versa.
As was the case with the RezΓ© catchment, the same trends and tendencies can be observed independently of the simulation
periods and configurations. Simulation 13 can once again be cited as the best configuration of parameters, with a KGE 10
criterion of 0.79 over the whole simulation period. Parameter Ip can thus be set at 0.09 and Ird at 10-5, whereas Dβ is variable.
5.2.3 General discussion
In terms of calibration and evaluation processes, this model exhibits the tendency to overestimate the observed total sewer
discharge. This skewing can be explained by the choice of setting parameter ππππ at its real value rather than calibrating the
model on it. This parameter is indeed the one exerting a predominant influence on total sewer discharge, since it directly 15
conditions the surface runoff of impervious surfaces. When calibrating the model on total sewer discharge, it is thus essential
to take this parameter into account in case it is not well known, as opposed to other parameters πΌππ and π·β that exercise little
influence over this process. Evaluating the model from the standpoint of sewer discharge due to soil water infiltration
however requires a more detailed consideration of πΌπ and π·β. The water exchanges taking place between the urban subsoil
and both the natural and sewer network are critical processes in urban areas. As shown above, the model is very sensitive to 20
them and comparing them to observation findings can help improve the simulated urban water budget, yet experimental data
on such fluxes are indeed rare.
For both catchments, the statistical criteria indicate the same trend throughout all simulation configurations and periods, with
a better KGE for the first period. The model seems to perform better under wetter climatic conditions. The best simulation
configuration is the same irrespective of calibrating the model on the first or second period, with the exception of Simulation 25
14. It thus proves necessary to apply the model more extensively in regions with different meteorological patterns in order to
investigate whether the model could operate under different meteorological conditions (dry and wet periods), which is an
essential condition for projection applications. The same simulation configuration yields the best results for both the RezΓ©
and Pin Sec catchments. Considering their differences in terms of soil texture and urban patterns (mean building height), this
is an encouraging result for working at the city scale, as spatial heterogeneity no longer constitutes an obstacle. 30
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
16
6. Conclusion
The objective of this study has been to contribute to developing a complete urban hydro-microclimate model and testing the
ability of this model to replicate hydrological processes. This goal has been achieved given that the representation of
hydrological processes in the TEB-Veg model (Lemonsu et al., 2012) has been extended and refined. The new model
version, called TEB-Hydro, has been developed by taking a detailed representation of the urban subsoil into account. This 5
step has enabled horizontal interactions of soil moisture between the urban subsoil of built-up and natural surfaces within a
single grid-cell. Furthermore, the drainage of soil water via the sewer network has been introduced in the road compartment
of the model. Deep drainage, which normally supplies the base flow of the natural river network, has been limited to
favouring humidification of the lower soil layers, resulting in more realistic infiltration patterns into the sewer network under
urban conditions. A sensitivity analysis has been performed in the aim of better understanding the influences of model 10
parameters on these processes and identifying the parameters to serve calibration purposes. Six parameters were
investigated, of which four seemed to significantly influence the model output in terms of total sewer discharge and the
portion of discharge caused by soil water infiltration, namely: the parameter (πΌπ) describing the water-tightness of the sewer
pipe, the road infiltration rate (πΌππ), the fraction of impervious surfaces connected to the sewer network (ππππ), and the
parameter (π·β) that enables limiting deep drainage out of the urban subsoil. 15
TEB-Hydro was then applied to two small residential catchments located close to the city of Nantes (France). In both cases,
the model was calibrated and evaluated on the observed sewer discharge, in displaying the same hydrological behaviour. The
total sewer discharge is consistently being overestimated, independent of both simulation period and configuration.
Considering parameter ππππ as a calibration element, should it not be known, allows tackling this problem. The model seems
to function better under wet conditions, since simulation period 1 offers better KGE results. In assessing the entire simulation 20
periods for both catchments, the same parameter configuration stands out, independently of meteorological and local
physical conditions, thus implying that the model is running in a coherent and steady manner. This finding would need to be
confirmed by applying the model to several catchments areas outside of Nantes. In conclusion, the evaluation outcomes laid
out herein are encouraging for application of the model at the city scale for purposes of projecting global change.
Lastly, a more detailed representation of the urban subsoil and its hydrological pattern enhances the model's urban water 25
budget. Given that the water and energy budgets are coupled, it is likely that the energy budget of the model is improved at
the same time. An upcoming research project is underway, which entails investigating alongside the hydrological processes
energy patterns like latent and sensible heat fluxes.
7. Code and data availability
The surface modelling platform SURFEX is accessible on open source, where the codes of surface schemes TEB and ISBA 30
can be downloaded (http://www.cnrm-game-meteo.fr/surfex/). This platform is regularly updated; however, the model
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
17
developments mentioned above have yet to be taken into account in the latest SURFEX, version v8.0. For all further
information or access to real-time code modifications, please follow the procedure in order to open the SVN account
provided via the previous link. The routines modified with respect to the TEB-Hydro model SURFEX v.7.3, as well as the
run directories of the model experiments described above can be retrieved via https://doi.org/10.5281/zenodo.1218016. The
RezΓ© and Pin Sec catchment databases are available upon request submitted to the authors of the Water and Environment 5
Laboratory of the French Institute of Science and Technology for Transport, Development and Networks (IFSTTAR).
References
Abramopoulos, F.; Rosenzweig, C. and Choudhury, B.: Improved Ground Hydrology Calculations for Global Climate
Models (GCMs): Soil Water Movement and Evapotranspiration, Journal of Climate, 1, 921-941, 1988.
Bach, P. M., Rauch, W., Mikkelsen, P. S., Mc Carthy, D. T., and Deletic, A.: A critical review of integrated urban water 10
modelling β Urban drainage and beyond . Environmental Modelling & Software , 54, 88-107, 2014.
Belhadj, N.; Joannis, C. and Raimbault, G.: Modelling of rainfall induced infiltration into separate sewerage. Water Science
and Technology , 32, 161 - 168, 1995.
Berthier, E.: Contribution à une modélisation hydrologique à base physique en milieu urbain: Elaboration du modèle et
première évaluation, Université Joseph-Fourier (UJF), Institut National Polytechnique de Grenoble, Grenoble, 1999. 15
Berthier, E., Andrieu, H., and Rodriguez, F.: The RezΓ© urban catchments database. Water Resources Research, 35(6), 1915-
1919, 1999.
Berthier, E., Andrieu, H., and Creutin, J.: The role of soil in the generation of urban runoff: development and evaluation of a
2D model . Journal of Hydrology , 299(3β4), 252-266, 2004.
Berthier, E., Dupont, S., Mestayer, P. and Andrieu, H.: Comparison of two evapotranspiration schemes on a sub-urban site 20
Journal of Hydrology , 328, 635 - 646, 2006.
Betts, R. A.: Implications of land ecosystem-atmosphere interactions for strategies for climate change adaptation and
mitigation, Tellus B. Chemical and Physical Meteorolgy, 59:3, 602-615, 2007.
Boone, A., Masson, V., Meyers, T., and Noilhan, J.: The Influence of the Inclusion of Soil Freezing on Simulations by a
SoilβVegetationβAtmosphere Transfer Scheme. Journal of Applied Meteorology, 39, 1544β1569, 2000. 25
Bouilloud, L., Martin, E., Habets, F., Boone, A., Moigne, P. L., Livet, J., Marchetti, M., Foidart, A., FranchistΓ©guy, L.,
Morel, S., Noilhan, J. and PettrΓ©, P. Road Surface Condition Forecasting in France. Journal of Applied Meteorology and
Climatology, 48, 2513-2527, 2009.
DHI: Mike Urban cs: Building a simple Mouse Model in Mike Urban. Step-by-step Training Guide, 2001.
Dupont, S.: Modélisation dynamique et thermodynamique de la canopée urbaine: réalisation du modèle de sols urbains pour 30
SUBMESO, Ecole Doctorale MΓ©chanique Thermique et GΓ©nie Civil, UniversitΓ© de Nantes, Nantes, 2001.
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
18
Dupont, S., Mestayer, P. G., Guilloteau, E., Berthier, E. and Andrieu, H.: Parameterization of the Urban Water Budget with
the Submesoscale Soil Model. Journal of Applied Meteorology and Climatology, 45, 624-648, 2006.
EC (European Commission): Towards an EU Research and innovation agenda for nature-based solutions and re-naturing
cities, Brussels: CEC, 2015.
EEA: Urban adaptation to climate change in Europe: Challenges and opportunities for cities together with supportive 5
national and European policies. Tech. rep., European Environment Agency, EEA Copenhagen, 2012.
Entekhabi, D. and Eagleson, P. S.: Land Surface Hydrology Parameterization for Atmospheric General Circulation models
Including Subgrid Scale Spatial Variability. Journal of Climate, 2, 816-831, 1989.
Faroux, S.; KaptuΓ© TchuentΓ©, A. T.; Roujean, J.-L.; Masson, V.; Martin, E. and Le Moigne, P.: ECOCLIMAP-II/Europe: a
twofold database of ecosystems and surface parameters at 1 km resolution based on satellite information for use in land 10
surface, meteorological and climate models. Geoscientific Model Development, 6, 563-582, 2013.
Fletcher, T., Andrieu, H., and Hamel, P.: Understanding, management and modelling of urban hydrology and its
consequences for receiving waters: A state of the art . Advances in Water Resources , 51, 261-279, 2013.
Furusho, C: Base de donnΓ©es FluxSAP IRSTV - Projet ANR-VegDUD, 2012.
Grimmond, C. S. B.; Blackett, M.; Best, M. J.; Baik, J.-J.; Belcher, S. E.; Beringer, J.; Bohnenstengel, S. I.; Calmet, I.; Chen, 15
F.; Coutts, A.; Dandou, A.; Fortuniak, K.; Gouvea, M. L.; Hamdi, R.; Hendry, M.; Kanda, M.; Kawai, T.; Kawamoto, Y.;
Kondo, H.; Krayenhoff, E. S.; Lee, S.-H.; Loridan, T.; Martilli, A.; Masson, V.; Miao, S.; Oleson, K.; Ooka, R.; Pigeon, G.;
Porson, A.; Ryu, Y.-H.; Salamanca, F.; Steeneveld, G.; Tombrou, M.; Voogt, J. A.; Young, D. T. and Zhang, N.: Initial
results from Phase 2 of the international urban energy balance model comparison. International Journal of Climatology,
John Wiley & Sons, Ltd., 31, 244-272, 2011. 20
Gros, A.; Bozonnet, E.; Inard, C. and Musy, M.: Simulation tools to assess microclimate and building energy β A case study
on the design of a new district. Energy and Buildings, 114, 112 - 122, 2016.
Gupta, H. V.; Kling, H.; Yilmaz, K. K. and Martinez, G. F.: Decomposition of the mean squared error and NSE performance
criteria: Implications for improving hydrological modelling. Journal of Hydrology, 377, 80-91, 2009.
Hamel, P., Daly, E., and Fletcher, T. D.: Source-control stormwater management for mitigating the impacts of urbanisation 25
on baseflow: A review . Journal of Hydrology , 485, 201-211, 2013.
Le Delliou, A.-L., Rodriguez, F. and Andrieu, H.: ModΓ©lisation intΓ©grΓ©e des flux d'eau dans la ville - impacts des rΓ©seaux
d'assainissement sur les Γ©coulements souterrains. La Houille Blanche, 152-158, 2009.
Lemonsu, A., Masson, V., and Berthier, E.: Improvement of the hydrological component of an urban soilβvegetationβ
atmosphereβtransfer model. Hydrological Processes, 21(16), 2100-2111, 2007. 30
Lemonsu, A., Masson, V., Shashua-Bar, L., Erell, E., and Pearlmutter, D.: Inclusion of vegetation in the Town Energy
Balance Model for modeling urban green areas. Geoscientific Model Development, 5, 1377-1393, 2012.
Lerner, D. N.: Identifying and quantifying urban recharge: a review. Hydrogeology Journal, 10, 143-152, 2002.
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
19
Malys, L.; Musy, M. and Inard, C.: Direct and Indirect Impacts of Vegetation on Building Comfort: A Comparative Study of
Lawns, Green Walls and Green Roofs. Energies, 9, 2016.
Mitchell, V. G.; Cleugh, H. A.; Grimmond, C. S. B. and Xu, J.: Linking urban water balance and energy balance models to
analyse urban design options. Hydrological Processes, John Wiley & Sons, Ltd., 22, 2891-2900, 2008.
Masson, V.: A Physically-Based Scheme For The Urban Energy Budget In Atmospheric Models. Boundary-Layer 5
Meteorology, 94(3), 357-397, 2000.
Masson, V.; Le Moigne, P.; Martin, E.; Faroux, S.; Alias, A.; Alkama, R.; Belamari, S.; Barbu, A.; Boone, A.; Bouyssel, F.;
Brousseau, P.; Brun, E.; Calvet, J.-C.; Carrer, D.; Decharme, B.; Delire, C.; Donier, S.; Essaouini, K.; Gibelin, A.-L.;
Giordani, H.; Habets, F.; Jidane, M.; Kerdraon, G.; Kourzeneva, E.; Lafaysse, M.; Lafont, S.; Lebeaupin Brossier, C.;
Lemonsu, A.; Mahfouf, J.-F.; Marguinaud, P.; Mokhtari, M.; Morin, S.; Pigeon, G.; Salgado, R.; Seity, Y.; Taillefer, F.; 10
Tanguy, G.; Tulet, P.; Vincendon, B.; Vionnet, V. and Voldoire, A.: The SURFEXv7.2 land and ocean surface platform for
coupled or offline simulation of earth surface variables and fluxes. Geoscientific Model Development, 6, 929-960, 2013.
Montgomery, D. C.: University, A. S. (Ed.) Design and Analysis of Experiments, John Wiley &Sons Inc., 2017.
Musy, M.; Malys, L.; Morille, B. and Inard, C.: The use of SOLENE-microclimat model to assess adaptation strategies at the
district scale. Urban Climate, 14, 213 - 223, 2015. 15
Oke, T.: Boundary Layer Climates (Γ©d. 2d ed). (Routledge, Γd.), 1987.
Ramier, D.; Berthier, E. and Andrieu, H.: The hydrological behaviour of urban streets: long-term observations and modelling
of runoff losses and rainfallβrunoff transformation. Hydrological Processes, John Wiley & Sons, Ltd., 25, 2161-2178, 2011.
Rodriguez, F.; Andrieu, H. and Creutin, J.-D.: Surface runoff in urban catchments: morphological identification of unit
hydrographs from urban databanks. Journal of Hydrology , 283, 146 - 168, 2003. 20
Rodriguez, F., Andrieu, H., and Morena, F.: A distributed hydrological model for urbanized areas β Model development and
application to case studies . Journal of Hydrology , 351(3β4), 268-287, 2008.
Rossman, L. A.: Storm water management model user's manual, version 5.0 National Risk Management Research
Laboratory, Office of Research and Development, US Environmental Protection Agency Cincinnati, 2010.
Salvadore, E., Bronders, J., and Batelaan, O.: Hydrological modelling of urbanized catchments: A review and future 25
directions . Journal of Hydrology , 529, Part 1, 62-81, 2015.
Saltelli, A.; Tarantola, S.; Campolongo, F. and Ratto, M.: Sensitivity Analyseis in Practice: a guide to assessing scientific
models, John Wiley & Sons, Ltd, 2004.
Schirmer, M., Leschik, S., and Musolff, A.: Current research in urban hydrogeology β A review . Advances in Water
Resources , 51, 280-291, 2013. 30
Seveno, F., Rodriguez, F., de Bondt K. and Joannis C.: Identification and representation of water pathways from production
areas to urban catchment outlets: a case study in France, 2nd International Conference on the Design, Construction,
Maintenance, Monitoring and Control of Urban Water, Germany, 2014.
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
20
Tang, T.; Reed, P.; Wagener, T. and Van Werkhoven, K.: Comparing sensitivity analysis methods to advance lumped
watershed model identification and evaluation. Hydrology and Earth System Sciences Discussions, 3, 3333-3395, 2006.
5
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
21
Table 1: Summary of basin characteristics for both the RezΓ© and Pin Sec catchments
Description RezΓ© Pin Sec
Surface area 4.7 ha 31.3 ha
Housing type Residential
(individual)
Residential
(individual and multi)
Mean building height (Hmean) 5.9 m 9.3 m
garden
Land use building
road
55%
17%
28%
49%
19%
32%
Soil texture clay
sand
40%
38%
8%
51%
Imperviousness of the surface area 45% 51%
Impervious surfaces connected to the sewer 84% 61%
Length of sewer network wastewater
storm drain
803 m
480 m
3,911 m
6,972 m
Mean sewer depth 1.50 m 1.50 m
Table 2: Description of the hydrological parameters of the TEB-Hydro model as well as its MIN, MAX and REF values for the
sensitivity analysis 5
Simulation Parameter Description Unit Values
MIN REF MAX
SROAD ππππ₯,πππ π’ππ
Maximum retention capacity of the road
surface reservoir mm 0.5 3.0 6.0
SROOF ππππ₯,πππ π’ππ
Maximum retention capacity of the roof
surface reservoir mm 0.25 1.5 3.0
IP πΌπ Parameter that describes the water-tightness
of the sewer pipe - 10-3 10-1 1
IROAD πΌππ Infiltration rate through the road mm s-1 10-9 10-6 10-5
CONN ππππ Fraction of impervious surfaces connected to
the sewer network - 0.5 0.7 0.9
DRAIN π·β Deep drainage % 0 5 10
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
22
Table 3: All factors with their levels and assigned values according to the sensitivity analysis classification
Parameter Level -1 Level +1
π°π 10-3 1
π°ππ 10-9 10-4
π«β 0 10
Table 4: Statistical criteria (r, Ξ±, Ξ², KGE) based on the model output variables, as calculated between the MIN and MAX
simulations, of each parameter and the reference simulation (REF)
Output variable Simulation MIN criteria MAX criteria
r Ξ± Ξ² KGE r Ξ± Ξ² KGE
ππ‘ππ€ππ‘ππ‘
SROOF 1.00 1.01 1.06 0.94 1.00 0.99 0.96 0.96
SROAD 0.99 1.04 1.11 0.88 0.99 0.96 0.94 0.93
IROAD 1.00 1.00 1.01 0.99 1.00 0.98 0.94 0.94
CONN 1.00 0.73 0.75 0.64 1.00 1.28 1.25 0.63
IP 1.00 1.00 0.93 0.93 1.00 1.01 1.41 0.59
DRAIN 0.91 1.20 1.80 0.17 1.00 1.00 0.99 0.99
ππ ππ€
SROOF 1.00 1.01 1.06 0.94 1.00 0.99 0.96 0.96
SROAD 0.99 1.04 1.11 0.88 0.99 0.96 0.94 0.93
IROAD 1.00 0.99 0.99 0.98 1.00 1.05 1.09 0.90
CONN 0.99 1.19 1.21 0.72 0.98 0.82 0.78 0.72
IP 1.00 0.01 0.01 -0.40 0.99 7.43 7.0 -7.79
DRAIN 0.78 20.51 11.47 -21.14 1.00 0.90 0.84 0.81
5
Table 5: Range of values for each parameter tested for use in calibration
πΌπ[-] 0.09 0.3 0.6 1
πΌππ[mm s-1] 10-8 10-7 10-6 10-5
π·β[%] 1 2 3.5 5
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
23
Figure 1: Schema of the hydrological processes involved in the TEB-Hydro model; subscripts rf and bld stand for building
compartment, rd for road compartment, and gdn for garden compartment
Figure 2: a) the experimental RezΓ© site (from Dupont, 2001); b) the experimental Pin Sec site. Maps to the right of the catchments 5 indicate the location of Nantes (France) above and the RezΓ© and Pin Sec catchment locations (red square) in Nantes (middle)
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
24
Figure 3: Comparison of urban runoff (πΉππππ) between the reference simulation (REF) and both the MIN simulation (shown in
blue) and MAX simulation (red) for the parameters: a) πΎπππ,ππ ππππ
(left side), and b) πΎπππ,ππππππ
(right side).
5
Figure 4: a) Comparison of urban runoff (πΉππππ) between the reference simulation (REF) and both the MIN simulation (blue) and
MAX simulation (red) for parameter π°ππ on the left side; and b) comparison of the sewer runoff due to soil water infiltration
(πΉπππ) between the reference simulation (REF) and the MIN (blue) and MAX (red) simulations for parameter π°ππ on the right side
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
25
Figure 5: Comparison of urban runoff (πΉππππ) between the reference simulation (REF) and the MIN (blue) and MAX (red)
simulations for parameter πππ¨π§
Figure 6: Calculated effects on the model response (πΉπππ) of parameters π°π, π°ππ and π«β and their interactions. (dark shade of 5
grey: principal effects, middle grey: second-order effects, and light grey: third-order effects)
IP
IROAD
DRAIN
IP/IROAD
IP/DRAIN
IROAD/DRAIN
IP/IROAD/DRAIN
-3,0E-04
-2,0E-04
-1,0E-04
0,0E+00
1,0E-04
2,0E-04
3,0E-04
4,0E-04
e(*
)
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
26
Figure 7: Comparison of sewer runoff due to soil water infiltration (πΉπππ) between the reference simulation (REF) and the MIN
(blue) and MAX (red) simulations for parameters a) π°π (left side) and b) π«β (right side)
Figure 8: Interactions as a function of the maximum observed sewer runoff due to soil water infiltration during winter 1994-95 of 5 the second order between parameters: a) π°π and π°ππ ; b) π°π and π«β and of third order between parameters c) π°π, π°ππ and π«β
0,0E+00
5,0E-05
1,0E-04
1,5E-04
2,0E-04
2,5E-04
3,0E-04
3,5E-04
-1 0 1
Qm
ax
IP
a) IP/IROAD
IROAD (+1)
IROAD (-1)
0,0E+00
1,0E-04
2,0E-04
3,0E-04
4,0E-04
5,0E-04
-1 0 1
Qm
ax
IP
b) IP/DRAIN
DRAIN (+1)
DRAIN (-1)
0,0E+00
5,0E-05
1,0E-04
1,5E-04
2,0E-04
2,5E-04
3,0E-04
-1 0 1
Qm
ax
IROAD
c) IROAD/DRAIN
DRAIN (+1)
DRAIN (-1)
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
27
Simulations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
πΌπ 0.09 0.3 0.6 1 0.09 0.3 0.6 1 0.09 0.3 0.6 1 0.09 0.3 0.6 1
πΌππ 10-8 10-8 10-8 10-8 10-7 10-7 10-7 10-7 10-6 10-6 10-6 10-6 10-5 10-5 10-5 10-5
π·β 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
Figure 9: Example of a calculated criterion for the simulation configurations where parameter πβ (deep drainage) is limited to 2% 5 and all other parameters allowed to vary. The KGE criterion, the correlation criterion (r), the variability criterion (Ξ±) and the bias
(Ξ²) for all 16 simulations and for the first (dark grey) and second (light grey) simulation periods are shown.
0,00
0,20
0,40
0,60
0,80
1,00
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
KG
E
Period 1 Period 2
0,80
0,85
0,90
0,95
1,00
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
r
1,00
1,10
1,20
1,30
1,40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Ξ±
0,80
1,00
1,20
1,40
1,60
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Ξ²
Simulations
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.
28
Figure 10: Comparison of simulated and observed total sewer discharge [l s-1] during: a) the first simulation period from
September 1993 to August 1995 (left side); and b) the second simulation period from September 1995 to August 1997 (right side)
for Simulation 13 and a deep drainage limited to 2%
5
Figure 11: Simulated sewer discharge due to soil water infiltration during the first simulation period 1993-95 based on the
combination of parameters ππ© set at 0.09 and ππ«π set at 10-5 and: a) πβ limited to 2%, b) πβ limited to 1%, and c) based on the
combination of parameters ππ© set at 0.3, ππ«π set at 10-5, with πβ limited to 2%
Geosci. Model Dev. Discuss., https://doi.org/10.5194/gmd-2018-39Manuscript under review for journal Geosci. Model Dev.Discussion started: 25 April 2018cΒ© Author(s) 2018. CC BY 4.0 License.