important information about baltic inflatable lifejackets. 11. check the expiry date of the...

8
IMPORTANT INFORMATION ABOUT Baltic inflatable lifejackets How they operate • Pre-wear and annual inspection • Rearming • Spare parts

Upload: hoangminh

Post on 07-May-2018

215 views

Category:

Documents


3 download

TRANSCRIPT

important information about

baltic inflatable lifejacketsHow they operate • Pre-wear and annual inspection • Rearming • Spare parts

2

AnnuAl inSPectionthe importance of annual inspection!Inflatable lifejackets require inspection regardless of whether they have been inflated or not. A pre-wear check can be done by following the instructions on the next page. Failure to carry out the annual inspection may cause your inflatable lifejacket to malfunction! The annual inspection is best carried out by our accredited service

stations, or as an alternative you can perform a simplified inspection yourself. Refer to page 4 in this information brochure for instructions. Information of our accredited service stations are to be found on our web page: www.baltic.se

Inflatable lifejackets have an inflation valve either automatic or manualconnected to an airtight bladder. To operate the manual valve you simply pull the toggle on the right hand side of the jacket downwards with a jerk and the bladder will start to inflate immediately. The automatic lifejacket will operate and inflate once it has been immersed in water for three seconds. The automatic can be operated

manually and both types can be inflated orally by the tube. The oral tube is used to deflate the lifejacket. N.B! After gas inflation the life-jacket must be rearmed. Inside the lifejacket you will find instructions as to which rearming kit to use. Instructions to complete the reaming procedure are included with our reaming kits.

baltic inflatable lifejacket inflated

baltic inflatable lifejacket deflated

Oral inflation/deflation tube

Lifting becket

Inflation mechanism

Pull cord

Part number forrearming kit

Whistle

Inspection history

Retro reflectivepatches

How tHey oPeRAte

3

Cartridge

PRe-weAR cHeck

every time you wear your inflatable lifejacket you should check the following:

1. check the co2 cylinderUnscrew the CO2 cylinder anti clockwise and make sure it is not pierced. Screw the unpierced CO2 cylinder back tightly by hand clockwise. A pierced CO2 cylinder is empty and must be replaced.

2. check the safety indicators and cartridge/bobbinAutomatic version:Check both safety indicators. If either of the green indicators is missing and/or the CO2 cylinder is pierced the lifejacket must be rearmed. Carefully follow the instruc-tions on the next page or the instructions enclosed with our rearming kits. Check that the cartridge/bobbin is in date. See page 6.

Manual version:Check the safety indicator. If it is missing, the CO2 cylin-der is empty and must be replaced. Carefully follow the instructions on page 5 or the instructions enclosed with our rearming kits.

3. check pull knobCheck that the manual inflation pull knob is accessible when donned.

United Moulders automatic valve Halkey Roberts automatic valve The bobbin is inside the transparent cup.

United Moulders manual valve Halkey Roberts manual valve

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

1. 2. 3. 4. 5.

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

1. 2. 3. 4. 5.

1. 2. 3. 4. 5.

1. 2. 3. 4. 5.

1. 2. 3. 4. 5.

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

1. 2. 3. 4. 5.

1

5

8

9

6

7

2 3

4

1. 2. 3. 4. 5.

1010

11 12

13

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

10.

11.

JAN FEB MAR APR

United Moulders

03 = MAR07 = 2007

MAX 2007

EXPDATE0307

04 + 3 = 2007

JAN FEB MAR APR

19MAX 2007

MAX 3

2003 2004 2005 2006 2007 2008

Halkey Roberts

12.

UM HR

13.

Vikningssekvenser från katalog Winner och Baltic 150

United Moulders

United Moulders

Halkey Roberts

Halkey Roberts

4

AnnuAl Self inSPectionInflatable lifejackets demand regular inspections whether or not they have been used. Failure to carry out inspections may cause your lifejacket to malfunction. Follow the instructions below to perform a simplified annual self inspection. We recommend that you have one of

our accredited service stations complete an enhanced certified annual inspection. For further information of our accredited service stations please visit our website: www.baltic.se

Check the expiry date of the cartridge/bobbin as described on page 6.

Repack the lifejacket by following the instructions on page 6.

united Moulders

Halkey roberts

5

NB! This is a smaller format of the instructions attached to our rearming kits.

ReARMinGunited Moulders or Halkey Roberts?Depending on the model or year of manufacture the inflation mechanism will be Halkey Roberts or United Moulders. These mechanisms are manual or automatic. To be able to replace indicator clips, cartridges,

bobbins or CO2 cylinders you will need to identify the mechanism your lifejacket is equipped with. Compare the inflation mechanism in your inflatable lifejacket with the mechanisms illustrated below.

united Moulders

Halkey roberts

Winner, Delta

Bluewater 150

6

Versions closed by zip

• Move the slider back to the starting position on the left side of the lifejacket.• Make sure the pull cord and its knob is protruding through the rear opening of the lifejackets cover before closing.• When closing the cover – Make sure you pull the slider to the first slide retainer at the end of the zip.

Deflation of an inflated lifejacket

Deflation of an inflated lifejacket

contRol of eXPiRy DAteS of cARtRiDGeS/ BoBBinS, DeflAtion AnD Re-PAckinG

united Moulders cartridge

On the cartridge is printed the expiry date.E.G. 0309, this would denote replace by March 2009.

Halkey roberts bobbin

NB. The Bobbin has a lifespan of four years and is printed with the date of manufacture. There are two different formats for the dates. Example 0650, which denotes year 2006 on the 50th day. Alternatively Feb19 06HRC, which denotes the 19th of February 2006. In recreational use the bobbin must be replaced no later than the third year from its first use. For industrial use please refer to your agent or service station.

++++++

7

important information!

former article number: Superceeded by article number:

Bobbin/Cartridge

2406

2520

2520

2406

2520

2406

CO2 cylinder

2433

2433

2420

2420

2416

2416

2433

cross reference table for rearming kits

SPARe PARtS foR ReARMinGFor maximum safety ensure only to fit genuine Baltic spares. The parts and kits listed below are available from our stockists

and service stations. Our service stations are listed on our web site: www.baltic.se

We have changed our rearming kits to reduce the storage time for cartridges and bobbins. All cylinders are supplied with both types of safety indicators. Please use table above to cross reference to our new article numbers.

N.B. Your old kit article number may be superceeded by two new article numbers. E.G. art no 2504 becomes 2433 plus 2406.

16 g cylinder with safety indicators ART NO 2416

10 g cylinder with safety indicatorsART NO 2410

bobbin Halkey robertsYellow bobbin has superceeded red bobbin. The bobbin is printed with the date of manufacture. Refer to page 6. ART NO 2406

20 g cylinder with safety indicators ART NO 2420

33 g cylinder with safety indicatorsART NO 2433

Safety indicators United Moulders, Halkey Roberts and Halkey Roberts Old. ART NO 2404

cartridge United MouldersCartridge. On the cartridge is printed the expiry date. Refer to page 6. ART NO 2520

Old rearming kit no (Manufacturer of inflation mechanism)

2504 (Halkey Roberts)

2503 (United Moulders)

2501 (United Moulders)

2511 (Halkey Roberts)

2522 (United Moulders)

2502 (Halkey Roberts)

2505 (Halkey Roberts & United Moulders)

Editio

n 0

8

ISO 9001:2000 CertifiedManufacturer of M.e.D./SolAS approved products

united kingdom office: Baltic Safety Products UK Ltd • Unit 4 Mitchell Point, Ensign Way, Hamble, SOUTHAMPTON SO31 4RF • Tel +44 2380 457 272 • Fax +44 2380 454 747

[email protected] • www.baltic.se

Head office: Baltic Safety Products AB (publ) • Box 60, S-545 02 ÄLgARåS, SWEDEN Tel +46 506 369 90 • Fax +46 506 401 96 • [email protected] • www.baltic.se