International Journal of Advanced Joint Reconstruction ISSN 2385-7900 Introduction Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges between 0.3 and 2.5% (1) and are a surgical challenge for surgeons, especially when they occur in old, multipathological patients, with bad bone quality, that are very vulnerable to immobilisation and often incapable to do partial weight bearing of the affected limb (2). These fractures have a death rate that ranges between 17% after 6 months and 30% during the first year, very superior to distal femur fractures or after total knee prostheses (3). It resembles the death rate of patients affected by a hip fracture (4), so therapeutic options must follow the same principles: early mobilisation, weight bearing and early deambulation with a stable knee and acceptable range of movement for daily life activities (3). Distal femoral replacement is an interesting option for the treatment of this type of fractures when performed by experimented surgeons in specialized centres (5). However, the use of tumour prostheses in non-oncological patients 2019; 6(1): 15-20. @IJAJR_HJ 15 Abstract Introduction: Periprosthetic knee fractures have a devastating effect on patients who suffer from them. Its death rate resembles that of patients affected by a hip fracture and the therapeutic options must follow the same principles. Presentation of the case: We present the clinical case of a 79-year-old lady with a type III periprosthetic knee fracture according to Su’s classification after an accidental fall. Before cleaning and reaming the femoral canal, a titanium band was used as a preventive cerclage. Then the available diaphyseal cones were tested to select the correct size implant after confirming that the femoral cemented stem passed through its interior. Part of the extruded cement was used as an interphase to avoid metallic friction, between the tantalum cone and the proximal ring of the femoral distal prosthesis. Discussion: When treating periprosthetic fractures, the results of the distal femoral replacement have higher complication rates. One of the causes for the early failure (loosening of femoral stem) is the poor bone quality, and on the other hand, the forces that the tumoral-type implants transmit to the bone-cement and cement-stem interphases during implantation. Conclusion: The use of tantalum cones to fill defects at the remaining femoral bone (hybrid fixation) may increase the torsional stability with a higher resistance to subside, improving the mid and long-term implant survival rates. Keywords Periprosthetic Knee fractures, Distal femoral replacement, Aseptic loosening, Hybrid fixation, Trabecular metal cones. CASE REPORT Distal femoral replacement in periprosthetic knee fractures. A hybrid fixation, using trabecular metal cones, to improve the survival implant. Murcia-Asensio A *, Ferrero-Manzanal F**, Lax-Pérez R*, Puertas-García-Sadoval JP**, Fernández-Fairén M ****, Martínez-González-Moro I*****. *Hospital General Universitario Reina Sofía, Avda. Intendente Jorge Palacios, 1, 30003 Murcia, Spain. **Hospital General Universitario Santa Lucía, C/Mezquita, s/n, Paraje Los Arcos, 30202, Santa Lucía, Cartagena, Spain. ***Hospital Clínico Universitario Virgen de la Arrixaca. Ctra. Madrid-Cartagena, s/n, 30120 El Palmar, Murcia, Spain. ****Instituto de Cirugía Ortopédica y Traumatología de Barcelona, C/Diputación, 321-Pral. 2º Les Corts, 08029 Barcelona, Spain. *****Departamento de Fisioterapia, Edificio C, nº 26, 2º planta, ala izquierda, Campus de Espinardo, Universidad de Murcia, 30100 Murcia, Spain.

Upload: others

Post on 15-Jun-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IJAJR 201904 Distal femoral replacement in periprosthetic ...€¦ · Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges

International Journal of Advanced Joint Reconstruction ISSN 2385-7900 !

Introduction

Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges between 0.3 and 2.5% (1) and are a surgical challenge for surgeons,

especially when they occur in old, multipathological patients, with bad bone quality, that are very vulnerable to immobilisation and often incapable to do partial weight

bearing of the affected limb (2). These fractures have a death rate that ranges between 17% after 6 months and 30% during the first year, very superior to distal femur fractures or after

total knee prostheses (3). It resembles the death rate of patients affected by a hip fracture (4), so therapeutic options must follow the same principles: early mobilisation, weight

bearing and early deambulation with a stable knee and acceptable range of movement for daily life activities (3). Distal femoral replacement is an interesting option for the

treatment of this type of fractures when performed by experimented surgeons in specialized centres (5). However, the use of tumour prostheses in non-oncological patients

2019; 6(1): 15-20. @IJAJR_HJ 15

Abstract

Introduction: Periprosthetic knee fractures have a devastating effect on patients who suffer from them. Its death rate resembles that of patients affected by a hip fracture and the therapeutic options must follow the same principles. Presentation of the case: We present the clinical case of a 79-year-old lady with a type III periprosthetic knee fracture according to Su’s classification after an accidental fall. Before cleaning and reaming the femoral canal, a titanium band was used as a preventive cerclage. Then the available diaphyseal cones were tested to select the correct size implant after confirming that the femoral cemented stem passed through its interior. Part of the extruded cement was used as an interphase to avoid metallic friction, between the tantalum cone and the proximal ring of the femoral distal prosthesis. Discussion: When treating periprosthetic fractures, the results of the distal femoral replacement have higher complication rates. One of the causes for the early failure (loosening of femoral stem) is the poor bone quality, and on the other hand, the forces that the tumoral-type implants transmit to the bone-cement and cement-stem interphases during implantation. Conclusion: The use of tantalum cones to fill defects at the remaining femoral bone (hybrid fixation) may increase the torsional stability with a higher resistance to subside, improving the mid and long-term implant survival rates.

Keywords

Periprosthetic Knee fractures, Distal femoral replacement, Aseptic loosening, Hybrid fixation, Trabecular metal cones.

CASE REPORT

Distal femoral replacement in periprosthetic knee fractures. A hybrid fixation, using trabecular metal cones, to improve the survival implant.

Murcia-Asensio A *, Ferrero-Manzanal F**, Lax-Pérez R*, Puertas-García-Sadoval JP**, Fernández-Fairén M ****, Martínez-González-Moro I*****.

*Hospital General Universitario Reina Sofía, Avda. Intendente Jorge Palacios, 1, 30003 Murcia, Spain. **Hospital General Universitario Santa Lucía, C/Mezquita, s/n, Paraje Los Arcos, 30202, Santa Lucía, Cartagena, Spain. ***Hospital Clínico Universitario Virgen de la Arrixaca. Ctra. Madrid-Cartagena, s/n, 30120 El Palmar, Murcia, Spain.

****Instituto de Cirugía Ortopédica y Traumatología de Barcelona, C/Diputación, 321-Pral. 2º Les Corts, 08029 Barcelona, Spain. *****Departamento de Fisioterapia, Edificio C, nº 26, 2º planta, ala izquierda, Campus de Espinardo, Universidad de Murcia, 30100 Murcia, Spain.

Page 2: IJAJR 201904 Distal femoral replacement in periprosthetic ...€¦ · Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges

International Journal of Advanced Joint Reconstruction ISSN 2385-7900 !

presents a high number of complications (6), with elevated revision rates due to septic or mechanical failure (about 50%) and a rate of survival of 76% during 44 months (7).

We present the clinical case of a patient operated in our Hospital, with a hybrid fixation technique at the femoral part (cemented and non-cemented) with a tantalum cone (Zimmer,

Inc., USA) placed at the distal part of the femur, and a distal femoral reconstruction stem (Megasystem-C, Waldemar Link) cemented through the tantalum cone.

Case Report This is the case of a 79-year-old lady that had a medical

background of cardiac insufficiency, multifactorial respiratory insufficiency, acute renal insufficiency, intrinsic asthma and obesity. She presented with a type III

periprosthetic knee fracture of Su’s classification (8, Fig 1) after an accidental fall. She was operated under general anaesthesia in the supine position with the usual supports for a knee arthroplasty.

Preoperative medication consisted on 800 mg intravenous teicoplanin + 1 g intravenous tranexamic acid bolus. Ischemia cuff was not employed considering the possibility of having

to expand the approach. With a distal femoral excision estimated lower than 10 cm we performed a direct anterior approach and a standard parapatellar medial arthrotomy. Once the fracture pattern was

identified, the distal femoral segment was en bloc resected. Then the polyethylene and tibial tray were removed. Samples

obtained from articular fluid and peri-implant tissues were sent to Microbiology laboratory for culture. Before cleaning and reaming the femoral canal, a titanium

band was used as a preventive cerclage (Königsee Implantate GmbH) (Fig 2). Then the available diaphyseal cones were tested to select the correct size implant (Fig. 3). A L-sized

2019; 6(1): 15-20. @IJAJR_HJ 16

Figure 1. Preoperative radiology depicting a periprosthetic fracture of the distal femur, Type III according to Su’s classification.

Figure 3. Diaphyseal tantalum cone implantation.

Figure 2. Representation of the band cerclage employed to prevent fractures by Königsee Implantable GmbH (Germany) (left) and 3D image of the Tantalum cones (right).

Page 3: IJAJR 201904 Distal femoral replacement in periprosthetic ...€¦ · Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges

International Journal of Advanced Joint Reconstruction ISSN 2385-7900 !

diaphyseal cone was chosen after confirming than the spherical Endomodel system reamers (Waldemar Link) passed through its interior and also the 130 cm in-length

chosen stem. As happens with hinged-type prosthesis, in which liberating all femorotibial ligamentous connections needs soft tissues to

be tightened to avoid articular hyperextension (a cause for mechanical implant failure), the length of the distal femoral substitution (75 mm) didn’t fit with the applied bone excision (55 mm).

For the tibial component, the S Endomodel system’s tibial plateau was used along with a 120 cm cemented stem. Tests

were then made to check the correct rotation, patellar tracking and correct joint line to proceed to mark the position of the definitive components (length and rotation).

Intramedullary plugs were inserted at both tibial and femoral sides, pulsatile lavage was done and then the femoral canal was soaked with a saline/hydrogen peroxide mix under

constant intramedullary aspiration. Two high-viscosity 75 mg PALACOS cement packages containing gentamicin were used, one for each medullar canal. Part of the extruded cement was used as an interphase between the tantalum cone

and the proximal ring of the femoral distal prosthesis to avoid metallic friction between both components (Fig 4,5).

2019; 6(1): 15-20. @IJAJR_HJ 17

Figure 4. Cemented technique in the femoral side.

Figure 5. A Intraoperative image showing the distal femoral replacement assembly; B and C Postoperative radiology of the case; D Radiologic result at 1 month follow-up

Page 4: IJAJR 201904 Distal femoral replacement in periprosthetic ...€¦ · Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges

International Journal of Advanced Joint Reconstruction ISSN 2385-7900 !

Discussion

Tumoral prostheses were developed by the end of the 40s, as a method of limb salvage for extensive bone excisions in oncological pathologies, and were first implanted on 1949

(Stanmore). As the implants have evolved, the indications have been extended to other pathologies like peri-implant fractures, non-union, massive bone loss and complex

prosthetic revisions. However, the complication rates are high, exceeding the 60% in some cases (9), being infection the most frequent, followed by mechanical loosening. The survival rate of this type of

implants is 91,5% at one year, 80% at 2 years and around 70% at five years (3). The employed surgical technique depends on different

factors: the existence of prosthetic infection, the correct fixation of the implants, the kind of fracture and its comminution, the bone quality and the existence of a femoral stem at the ipsilateral hip because it may compromise the

length and fixation of the selected implants (10). The combination of hip and knee arthroplasties is getting more frequent in our environment with the progressive increase of

the lifespan. As well as in knee surgery, we have to pay special attention at the implant fixation areas (11). In the distal femoral replacement surgery, there is only a fixation area in zone 3

(diaphysis), with a termino-terminal contact between the remaining femur and the metallic prosthetic device with a good support for axial load allowing early deambulation, but

transmitting all the torsional resistance to the cemented stem (12) (Fig 6). We believe that one of the causes of the early mechanical

failure of these kind of fractures (loosening of femoral stem) is a consequence of the poor bone quality on one hand and, on the other hand, to the applied forces that the hinge-type

implants transmit to the bone-cement-stem interphases. According to the philosophy of achieving at least 2 areas of fixation in knee revision surgery, we think that the tantalum cone at the level of the distal femur could act as a zone 2

fixation area (metaphyseal) increasing the stability of the construct. It would increase the torsional resistance by its tapered shape, with osseointegration of the outer surface to

the host bone and cement fixation in the inner surface. It would also prevent the sinking of the stem (Fig 7). Cottino et al (13), after analysing 408 rotational hinges in non-oncological pathologies, established a possible

relationship between the decrease of revision rates due to aseptic loosening (4,5% in 10 years) to the use of metaphyseal uncemented stems, that could minimize the

stress at the bone-cement-implant interphases. The use of tantalum, in its different variants , such as cones or pillars, has been widely used in knee and hip revision surgery with excellent results for more than 10 years (14).

Technically, the diversity of shapes and sizes facilitates revision surgery, making it easier, minimizing the duration of surgery and the risk of infection (15). Its three-dimensional

2019; 6(1): 15-20. @IJAJR_HJ 18

Figure 6. Postoperative radiology showing termino-terminal contact.

Page 5: IJAJR 201904 Distal femoral replacement in periprosthetic ...€¦ · Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges

International Journal of Advanced Joint Reconstruction ISSN 2385-7900 !

structure, its porosity and friction surface favours bone integration even in the context of severe bone loss (16). The use of custom-made tantalum cones for its femoral level

application is not new, being used by various authors in mechanical loosening of oncological and non-oncological prosthetic surgery, allowing for a better fixation of the

surgical construct, with good short-term results (17,18). We think that the great variety of the available cones in the market, along with the possibility of drilling and cutting them when needed, allows to assure fixation and optimal

anchorage to the distal femur remnant, facilitating the surgery and reducing the cost of the surgery itself. We consider that the ideal fixation for the selected implants in

periprosthetic fractures in old patients is cemented. When treating periprosthetic fractures, the results of the distal femoral replacement after osteosynthesis failure are worst than when used primarily, with a higher complication rates

(12). The surgical team that performs this type of fracture must have experience in using distal femoral replacement as well as osteosynthesis techniques in order to chose the best

option based on the intraoperative findings. According to some authors, this type of surgery must be restricted to specialized centres and made by experimented surgeons sue to the high complication and mortality rate

(30% on the first year) (3,5).

Conclusions

Distal femoral replacement prosthesis must be a part of our therapeutic arsenal and we must be prepared to use them at the time of the surgery. The use of tantalum cones at the

remaining femoral bone (hybrid fixation) may increase the torsional stability with a higher subsidence resistance and may improve the mid and long-term implant survival rates.

References

1. Ricci WM. Periprosthetic femur fractures. J Orthop Trauma. 2015;29(3):130-7.

2. Saidi K, Ben-Lulu O, Tsuji M, Safir O, Gross AE, Backstein D. Supracondylar periprosthetic fractures of the knee in the elderly patients: a comparison of treatment using allograft-implant composites, standard revision components, distal femoral replacement prosthesis. J Arthroplasty. 2014;29(1):110-4.

3. Whitehouse MR, Mehendale S. Periprosthetic fractures around the knee: current concepts and advances in management. Curr Rev Musculoskelet Med. 2014;7(2):136-44.

4. Caeiro-Rey Jr. Tratamiento multidisciplinar de las fracturas osteoporóticas. Fracturas periprotésicas. Madrid: Sociedad Española de Cirugía Ortopédica y Traumatología; 2014.

5. Windhager R, Schreiner M, Staats K, Apprich S. Megaprostheses in the treatment of periprosthetic fractures of the knee joint: indication, technique, results and review of literature. Int Orthop. 2016;40(5):935-43.

6. Berend KR, Lombardi AV Jr. Distal femoral replacement

2019; 6(1): 15-20. @IJAJR_HJ 19

Fig 7. A A Zimmer metaphyseal femoral cones; B Zonal fixation in revision total Knee arthroplasty; C Megassytem-C Waldemark Link + diaphyseal femoral cones; D Resitance to sinking and torsion forces

Page 6: IJAJR 201904 Distal femoral replacement in periprosthetic ...€¦ · Periprosthetic knee fractures have a devastating effect on patients who suffer from them. The incidence ranges

International Journal of Advanced Joint Reconstruction ISSN 2385-7900 !

in nontumor cases with severe bone loss and instability. Clin Orthop Relat Res. 2009;467(2):485-92.

7. Korim MT, Esler CN, Ashford RU. Systematic review of proximal femoral arthroplasty for non-neoplastic conditions. J Arthroplasty. 2014;29(11):2117-21.

8. Su ET, DeWal H, Di Cesare PE. Periprosthetic femoral fractures above total knee replacements. J Am Acad Orthop Surg. 2004;12(1):12-20.

9. Rodríguez-Merchán EC. Total knee arthroplasty using hinge joints: Indications and results. EFORT Open Rev. 2019;4(4):121-132.

10. Soenen M, Baracchi M, De Corte R, Labey L, Innocenti B. Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips? J Arthroplasty. 2013;28(8):1437-45.

11. Morgan-Jones R, Oussedik SI, Graichen H, Haddad FS. Zonal fixation in revision total knee arthroplasty. Bone Joint J. 2015;97-B(2):147-9.

12. Chen AF, Choi LE, Colman MW, Goodman MA, Crossett LS, Tarkin IS, McGough RL. Primary versus secondary distal femoral arthroplasty for treatment of total knee arthroplasty periprosthetic femur fractures. J Arthroplasty. 2013;28(9):1580-4.

13. Cottino U, Abdel MP, Perry KI, Mara KC, Lewallen DG, Hanssen AD. Long-Term Results After Total Knee

Arthroplasty with Contemporary Rotating-Hinge Prostheses. J Bone Joint Surg Am. 2017;99(4):324-330.

14. Konan S, Duncan CP, Masri BA, Garbuz DS. Porous tantalum uncemented acetabularbcomponents in revision total hip arthroplasty: a minimum ten-year clinical, radiological and quality of life outcome study. Bone Joint J. 2016;98-B(6):767-71.

15. Koech H, Lawrenz JM, Mesko DR, Molloy RM. A novel use of a tibial cone in a proximal femoral replacement. Arthroplast Today. 2018;4(2):175-179.

16. Kamath AF, Lewallen DG, Hanssen AD. Porous tantalum metaphyseal cones for severe tibial bone loss in revision knee arthroplasty: a five to nine-year follow-up. J Bone Joint Surg Am. 2015;97(3):216-23.

17. Hackenberg RK, Nessler J, König DP. First application of segmental trabecular metal cones in a custom-made revision tumor prosthesis of the knee: A technical note. Technol Health Care. 2018;26(1):195-202.

18. McNamara CA, Gösthe RG, Patel PD, Sanders KC, Huaman G, Suarez JC. Revision total knee arthroplasty using a custom tantalum implant in a patient following multiple failed revisions. Arthroplast Today. 2016;3(1):13-17.

2019; 6(1): 15-20. @IJAJR_HJ 20

Copyright

Copyright © 2019 Murcia-Asensio A et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Conflicts of interest statement

The authors certify that they have no affiliations with or involvement in any organisation or entity with any financial interest, or non-financial interest in the subject matter or materials discussed in this manuscript.

How to cite

Murcia-Asensio A, Ferrero-Manzanal F, Lax-Pérez R, Puertas-García-Sandoval JP, Fernández-Fairén M, Martínez-González-Moro I. Distal femoral replacement in periprosthetic knee fractures. A hybrid fixation, using trabecular metal cones, to improve the survival implant. Int J Adv Jt Reconstr. 2019; 6(1):15-20.