Page 1: iics90_br_9050454_en

Infant Intensive Care System

Air-Shields® IICS-90

Emergency Care · Perioperative Care · Critical Care · Perinatal Care · Home Care Because you care

Page 2: iics90_br_9050454_en

performance acrossthe range

Caring for the youngest patients requires the bestand most innovative technology. But as we see it,newborn intensive care also requires somethingmore - emphasis on the NICU as a total environ-ment where infants can receive the therapies theyneed in a setting that is nurturing, yet designed forflexibility and efficiency.

Our CareArea Solution brings together the mostadvanced ventilation, monitoring and warming tech-nologies available to provide newborns with thehighest level of care. We then combine these tech-nologies with sophisticated information manage-ment systems to help caregivers make the vitaldecisions essential to a baby’s well being.

Our expertise in intelligent work-place designenhances the productivity of the NICU while alsomaking sure that it’s responsive to the needs of thefamily. The result? An all-encompassing solution forperinatal care that meets the highest standards.

Page 3: iics90_br_9050454_en

Draeger Medical, the leading name in perinatalcare, presents a family of Air-Shields® RadiantWarmers to meet the diverse thermoregulatoryrequirements of your hospital and your patients.From a compact, mobile freestanding warmer to afully integrated Intensive Care System, thesedevices can be equipped to supplement existinghospital systems, or to support the most compromised infants with a full range of integrated accessories.

The result: Legendary infant care products for over50 years, demonstrating our continued commitment to consistently providing the best solutions for your babies.

An exceptional response for exceptional patients

Page 4: iics90_br_9050454_en

integrated intensive care syste

Free Standing Warmer A compact mobile unit for usein all areas with existing hospital bassinets in a varietyof situations. Available in fixedheight only.

Infant Intensive Care SystemIICS-90Capable of providing any configuration to meet the hospital and infants requirements.Available in fixed or variableheight.

Temperature Control:Our systems offer reliable excellence in thermal performance. Each Warmer in the Air-Shields®

products family provides focused heater output across the mattress to achieve uniform temperature distribution. Combined with a quartz heatingelement, our systems are optimized for fast, reliable heating on demand. The warming modulehead can be moved 65˚ in either direction to facili-tate other procedures such as x-ray, without interrupting thermal operation.

Intuitive Operation:The large, bright displays can be seen from a wide angle, and all controls are designed for logical, intuitive operation.

Variable Height Adjustment (VHA):The VHA option maximizes comfort for cliniciansor parents seated at bedside. At maximum height,the patient is positioned appropriately for ECMO procedures.

Variable Bassinet Tilt:All bassinets include a smooth operating mattresstilt.

Side Panels:An organizer panel at the rear of the bassinet supports efficient cable management. Each panel can be opened or removed for cleaning. Each panel is marked to optimize positioning of x-ray cassette.

Storage Options:A selection of storage options are available, including various configuration of shelves, anddrawer modules to suit your hospital’s needs.

Phototherapy OptionAir-Shields® IICS-90’s integrated phototherapy system ensures that optimal therapeutic output is available on demand–without having to disturb the patient or move other equipment.

Page 5: iics90_br_9050454_en

ResuscitationA comprehensive range of resuscitation packages is available. The convenient location places all controls and displays readily accessible forCaregivers at all times.

Warm Weigh® Infant ScalesAt the touch of a button an accurate measurement of the infant’s weight may be taken with the optimal in-bed scale module. A re-weigh feature enablessubsequent weights to be taken, with reduced distur-bance to the infant.

Remote Alarm ModuleTakes the audible alarm tone away from the infant area and also displays alarm violations in a remote location promoting a low-noise, stress free environment.

The remote alarm will initiate alarm violations at a lower intensity, and will only increase if unattended.

X-Ray FacilityA conveniently located x-ray cassette tray enablesx-rays to be taken with minimal disturbance to the patient.

em

Every unit features dualmode operation includingfacility for manual and servoskin temperature control.

Fully equipped Warming Module shown with optional Phototherapy and Remote Alarm features

Warm®Weigh® Infant Scale Integrated X-ray tray

Page 6: iics90_br_9050454_en

packages

Resuscitation Package IIIIncorporates as standard:• 2 oxygen inlets and 2 oxygen outlets• 2 air inlets and 1 air outlet• 1 vacuum inlet and 1 vacuum outlet

Resuscitation Package III includes:• Resuscitation Module• Flowmeter without oxygen take-off• Pediatric suction, powered by oxygen(500 ml jar)• Pin indexed Oxygen Regulator,yoke, and pressure gauge for “E”cylinder with 3ft green DISS hose• Pin indexed Air Regulator, yoke, andpressure gauge for “E” cylinder with3ft yellow DISS hose• Tank mounting bracket for two “E”

size cylinders

All other accessories and hoses tobe ordered separately

Resuscitation Package III is for usewith the following Air-Shields® InfantWarmers:• Air-Shields® IICS-90 Warmers

(with/without VHA)

Deluxe Resuscitation Module with Blender MountIncorporates as standard:• 2 oxygen inlets and 1 oxygen outlet• 1 suction inlet and 1 suction outlet• Airway pressure gauge• Blender Mount

All other accessories and hoses tobe ordered separately

The Deluxe Resuscitation Module is foruse with the following Air-Shields® In-fant Warmers:• Infant Warmers for Delivery Room • IICS-90 Warmers

A range of resuscitation productsto meet the rigorous demands ofthe delivery room and NICU.

Resuscitation products for infant warmers

From the most straightforward resuscitation module to a fully configured resuscitation package, Draeger Medical has thesolution. The classic and deluxe resuscitation modules give you the ability to develop your own system and utilize existingequipment in your hospital. The Resuscitation Package III provides you with all the components necessary for a resuscita-tion procedure. Draeger Medical also offers a comprehensive range of resuscitation accessories to meet the varying needsof each hospital and each infant.

Classic Resuscitation ModuleIncorporates as standard:• 2 oxygen inlets and 1 oxygen outlet • Airway pressure gauge

All other accessories and hoses tobe ordered separately.

The Classic Resuscitation Module isfor use with the following Air-Shields®Infant Warmers:• Infant Warmers for Delivery Room • IICS-90 Warmers

Page 7: iics90_br_9050454_en

Power requirements 100 V AC, 50/60 Hz, 680 W (w/VHA) 110/120 V AC, 50/60 Hz, 680 W

220/240 V AC, 50/60 Hz, 680 WLeakage current 100 V, 120 V models: <300 µA

220 V-240 V models: <500 µA Heating element Quartz (600 W)Examination light 100 ft. candles at center mattress

1076 lux; 100 lumens per sq. ft.Skin temperature display Digital LED with 0.1˚ C ResolutionSkin temp. variability 0.2˚ C at temperature equilibriumMattress tilt ± 10˚Heater module swivel ± 65˚Casters 5” (Free Standing Warmer has 3 casters 2”)Mattress size in (cm) 29.5 (75) x 23.5 (59.7)EnvironmentalAmbient operating temp 68˚F (20˚ C) - to 86˚F (30˚ C)Humidity 0 - 95%Altitude Sea level to 1.9 miles (3 km)ControlsControl modes Skin Mode and Manual Mode (0-100% in 25% increments)Skin mode control range 34.0˚ C - 37.9˚ CSilence/reset Silences audible alarms for 15 minutes

Resets (clock) in Manual modeManual mode After 10 minutes of operation, an audible “chirp” tone

(Manual Alert) will sound every 30 seconds. The heater may then be reset for an additional 15 minutes without the heater turning off by pressing the Silence/Reset Switch. If the circuit is not reset, the heater is automatically turned off when 15 minutes of operation have elapsed, the MANUAL Indicator lights steady, and the alarm sounds.

Alarms Probe Fail, Power Fail, Set Point (Skin Mode ± 1.0˚ C)Remote alarm option Initiates large red lamp for alarm conditions(Standard with VHA modules) Initiates low volume audible which increases if unattendedPhototherapy optionLight output 9 µW/cm2/nm Bulb type 50 W Quartz Halogen White LightPower requirements 100 V AC, 50/60 Hz, 440 W

110/120 V AC, 50/60 Hz, 440 W220/240 V AC, 50/60 Hz, 440 W

Overload protection 100V and 110/120V models One 10A

Circuit Breaker (on Power Module of associated equipment)220/240V mode One 13A

Circuit Breaker (on Power Module of associated equipment)Chassis leakage current 100,120V models <300 µA220/240 models <500 µA

Technical specifications

Height Low 75 in (190.5 cm) 76.75 in (195 cm) 71 in (180 cm)

Height Mid - - 74 in (188 cm)

Height High 87 in (221 cm) 79in (201 cm) 77 in (195 cm)

Width, 28 in (71 cm) 28 in (71 cm) 28 in (71 cm)

Depth 49 in (124 cm) 46 in (117 cm) 38.5 in (98 cm)

Weight, lb (kg) 447 lb (202 kg) 226 lb (102.6kg) 103 lb (47 kg)

Mattress Height

Low 37 in (94 cm) 38 in (96 cm) -

High 49 in (124 cm) 40.5 in (102.8 cm) -

IICS-90 VHA IICS-90 Free Standing Warmer

Physical Characteristics

Page 8: iics90_br_9050454_en

Europe, Middle East, Africa, Latin America,Asia, Pacific:

Dräger Medical AG & Co. KGMoislinger Allee 53–5523542 LübeckGERMANYTel: +49-1805-3 72 34 37

+49-451-882-822Fax: +49-451-882-37 79E-mail: [email protected]

USA:

Draeger Medical, Inc.3135 Quarry Road Telford, PA 18969USATel: +1-215-721-5400Toll-free: +1-800-437-2437Fax: +1-215-723-5935E-mail: [email protected]

Canada:

Draeger Medical Canada Inc.120 East Beaver Creek Road Suite 104Richmond Hill Ontario L4B 4V1CANADATel: +1-905-763-3702Toll-free: +1-866-343-2273Fax: +1-905-763-1890E-mail: [email protected]

www.draeger-medical.com

90 5

0 45

4 /

10.0

6-3

/ P

equo

d C

omm

unic

atio

ns /

Prin

ted

in U

nite

d S

tate

s /

Chl

orin

e-fr

ee -

envi

ronm

enta

lly c

ompa

tible

/ S

ubje

ct to

mod

ifica

tions

/ ©

200

6 D

räge

r M

edic

al A

G &

Co.

KG

Manufacturer:Draeger Medical Systems, Inc.Telford, PA 18969, USA

The quality management system at Draeger Medical Systems, Inc. is certifiedaccording to ISO 13485, ISO 9001 and AnnexII of Directive 93/42/EEC (Medical devices).