Page 1: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

HYDROCLICK SYSTEM

Page 2: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

• Smooth surface

• Clean ability

• Resistance of lining against potable water

• (at chlorination up to 1 ppm)

• Absolute tightness

• No ground water infiltration through concrete wall (at buried tanks)

Currently used systems

• Tiles

• Coatings

• Concrete without further treatment

• Thermoplastic liners

DEMANDS ON POTABLE WATER TANKS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

2

Page 3: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Problem:Coating of potable water tanks

Limited service life Contamination of potable water by detached particles

POTABLE WATER TANKS - GENERAL

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

3

Page 4: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Problems caused by solvent water:

Service life ? Maintenance ? Repair ?

POTABLE WATER TANKS - GENERAL

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

4

Page 5: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

• Product approval acc. to KTW (for potable water)

• Raw material approval DVGW-W270 (for pot. water)

• No deposits on the tank wall

• Easy to clean – high pressure resistance (130bar)

• Good resistance against chlorination up to 3 ppm

(0,5 ppm free chlorine resp. 0,3 ppm ClO2)

• Long service life (PE-pipes 50 years)

• Fast installation / shorter construction times!

• Ventilation gap avoids creation of aggressive condensates

ADVANTAGES OF SYSTEM

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

5

Page 6: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

• extruded - calendared

• max. width: 2000mm

• thickness: 4mm

• material: PE80 blue RAL 5012

12-15mm

~ 2000mm

50mm

HYDROHYDROCLICKCLICK liner

HYDROHYDROCLICKCLICK profile

HYDROCLICK SYSTEM

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

6

Page 7: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

HYDROHYDROCLICKCLICK profile

coextruded with PEHD-el layer

Distance studs(height ~ 9mm)

Click stud(adjusted to the Click profile)

HYDROCLICK SYSTEM

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

7

Page 8: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Protective film

Perforation strip (on both sides 50mm)

HYDROCLICK SYSTEM

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

8

Page 9: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Easy installation:

• No extensive preparation before installation

• Tiles and coatings may be left in the tank if they are not loose

• Second chamber can be operated without special efforts (no dust or odours)

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

9

Page 10: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Wall installation

Step 1:

Sheet with click-studs is clicked into the profile which is mechanically fixed to the wall

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

10

Page 11: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Step 2:Second sheet is clicked into the profilePreparation of the welding area

Wall installation

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

11

Page 12: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Step 3:

Extrusion weldingDVS optimized

Wall installation

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

12

Page 13: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Ground-wall-transition

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

13

Page 14: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Wall connection / Margin sections

INSTALLATION

• EPDM bar• Stainless steel bar• Sealing strip

Connection withPE sheet strip

PE profilefixed

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

14

Page 15: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Drain section remains

Wall-ground-transition with 45° chamfer

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

15

Page 16: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Thermoformed elements

Lining of columns

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

16

Page 17: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Anchor element

INSTALLATION

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

17

Page 18: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Project: Brig Switzerland

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

18

Page 19: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Project: Vernate Switzerland

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

19

Page 20: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Project: Leuggern Switzerland

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

20

Page 21: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

Project: Leuggern Switzerland

21

Page 22: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Project: Völkingen Germany

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

22

Page 23: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

Project: Oberschlierbach Austria

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

23

Page 24: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

REFERENCES / PROJECTS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

24

Page 25: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

System limitations of the HYDROCLICK system

• Applicable up to a max. temperature change of 10 °C

• Max. application temperature: 30°C

• Not recommended for back pressure build up

between concrete and liner

• Not UV resistant

LIMITATIONS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

25

Page 26: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

APPROVALS

• Potable Water Tanks – general

• Hydroclick system

• Installation

• References

• Limitations

• Approvals

26

Page 27: HYDRO CLICK SYSTEM. Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground

AGRU Kunststofftechnik GmbHIng.-Pesendorfer-Str. 31

A-4540 Bad HallAustria / EU

www.agru.at

T +43 (0) 7258 790 - 0F +43 (0) 7258 3863E [email protected]

Subject to errors of typesetting, misprints and modifications. Illustration are generic and for reference only!

THANK YOU