hydraulic elevator brochure
TRANSCRIPT
-
8/13/2019 Hydraulic Elevator Brochure
1/8
The Solution SourceFor Low-Rise Applications
OTIS
Hydraulic Elevators
-
8/13/2019 Hydraulic Elevator Brochure
2/8
STEP 1: Travel Height
The elevator travel distance will help you select the
hydraulic elevator for your project.
Use the chart below to identify the most commonly
selected Otis hydraulic elevators for your specific
travel heights. Colors indicate recommended range
of minimum and maximum travel height.
STEP 2: Elevator Quantity and Size
Determining factors include floor population,
building use or type, as well as national and
local codes.
Stretcher access requirements by many states
include a minimum load capacity of 3,500 lbs. and
side-opening doors.
For additional help in selecting proper size and
number of elevators, refer to Architects Assistant
on Otis.com or contact your local Otis representative.
STEP 3: Hoistway Requirements
Additional hoistway space is required for heavier
reinforcements to rails in seismic zones 2 or greater.
Specific requirements can be determined by
reviewing individual product pages in this guide.
STEP 4: Machine/Control Room Requirements
Hydraulic systems require a separate machine
room at the bottom landing.
Locate machine room adjacent to hoistway at the
bottom landing or remotely.
STEP 5: Car Design and Finishes
Otis provides design and selection flexibility with
car walls, ceiling, lighting, handrails, bumper rails
and fixtures.
General Requirements by Others
Specific requirements for factors such as power,
smoke detectors, entrance-wall construction
and telephones are available in the General
Requirements By Others section of the typical
layout. For more information, consult your Otis
representative.
Standardized Installation
Relying on Otis standardized installation process
helps ensure elevator projects are completed on
schedule and within budget. We also systematically
visit project sites before installation to coordinate
general contractor efforts with our own. Thiscollaborative effort saves time and maintains the
highest standards for safety and quality.
Otis: Leading The Way In Hydraulic Elevators
As an industry leader, Otis Elevator Company offers the most advanced
hydraulic systems to meet the needs of your low-rise project.
Our E-Z Elevator Selection Process also makes it simple to choose your
elevator from our full line of hydraulic systems.
E-Z Elevator Selection Process
HolelessHydraulic
TelescopicHolelessHydraulic
TravelHeight
RopedHolelessHydraulic
HoledHydraulic
60
44
20
0
Elevator Selection Chart
Complying with CodeAll Otis hydraulic elevators comply with ASME/ANSI-
A17.1 and CAN/CSA-B44; Canada Barrier-free and ADA
guidelines; and ICC/ANSI-A117.1. Although local codes
may vary, Otis representatives can help ensure that
specific requirements are met.
Colors indicate recommended range of minimum and maximum travel height.
-
8/13/2019 Hydraulic Elevator Brochure
3/8
Travel Height
Maximum 20 ft
Maximum stops 3
Speed (ft/min) 100, 125
Key Attributes
No need for well hole drilling and itsassociated costs
Above-ground solution substantially reducesrisk of soil and ground water contamination
Applicable for:
Hazard-sensitive sites
Waterfront sites
Existing buildings
Available in both passenger and serviceelevator configurations and capacities
Solid-state starter improves performancethrough precise control of electric current
Optional:
Front and rear entrances
Ceiling height of 9-7
8-0 clear opening
Glassback
REM remote elevator monitoring
Hoisting Beam(Not by Otis)
Plunger
MachineRoom
C
L
F
D
G
A
B
I H J
K
E
SECTION
PLAN
Fluid Tank/Controller
Above-GroundCylinders
Car Buffer
Plungers
Holeless Hydraulic
Dimensions Passenger elevators Service elevators
Rated lbs. 2000 2100 2500 3000 3500 4500 5000 5000 AIA
Passenger Capacity 1 13/12 13/12 16/15 20/18 23/21 30/28 33/31 33/31
Car2
Interior width 5-8 5-8 6-8 6-8 6-8 5-8 5-11 5-8
Interior depth 4-3 4-3 4-3 4-9 5-5 7-11 8-6 9-0
Interior height 8-0 (Optional 9-7 )
Car door width 3-0 3-0 3-6 3-6 3-6 4-0 4-6 4-0
Hoistway
Width 7-4 7-4 8-4 8-4 8-4 7-7 8-4 7-7
Width in seismic zones3 7-6 7-6 8-6 8-6 8-6 7-7 8-4 7-7
Depth4 5-9 5-9 5-9 6-3 6-11 9-8 10-3 10-9
Rough opening width 4-8 4-8 5-2 5-2 5-2 5-8 6-2 5-8
Rough opening height 7-10
Clear opening height 7-0 (Optional 8-0 )
Clear overhead to hoist beam@ 100 ft/min 12-4 12-4 12-4 12-4 12-4 12-4 12-5 12-4
@ 125 ft/min 12-7 12-7 12-7 12-7 12-7 12-7 12-8 12-7
Minimum pit depth5 4-0 (5-0 for Canadian Province of Ontario)
Machine Room
Number of elevators in group 1 2 3 4
Width x depth 5-9 x 7-4 11-6 x 8-6 17-0 x 8-6 22-0 x 8-6
L
A
B
C
D
E
F
G
H
I
J
K
1 Capacity code requirements: US/Canada.
2 Interior dimensions may vary depending on interior finishes.
3 In seismic zones 2 or greater.
4 For cars with front and rear doors, add 914 to depth for 2000 to
3500 lb. capacities; add 1214 for 4500 and 5000 lb. capacities.
5 Pit depth changes based on speed: For 100 fpm, pit depth
increases 1 in depth for each 1 increase in rise over 13-7 up to 20-0.
For 125 fpm, pit depth increases 1 in depth for each 1 increase in
rise over 12-8 up to 20-0.
-
8/13/2019 Hydraulic Elevator Brochure
4/8
Travel Height
Maximum 44 ft 1 in
Maximum stops 5
Speed (ft/min) 100, 125
Key Attributes
No need for well hole drilling and itsassociated costs
Above-ground solution substantially reducesrisk of soil and ground water contamination
Applicable for:
Hazard-sensitive sites
Waterfront sites
Existing buildings
Available in passenger elevator configurationsand capacities only
Solid-state starter improves performancethrough precise control of electric current
Optional:
Front and rear entrances
Ceiling height of 9-7
8-0 clear opening
Glassback
REM remote elevator monitoring
oisting BeamNot by Otis)
lunger
Machineoom
C
L
F
D
G
A
B
I H J
K
E
ECTION
PLAN
Fluid Tank/Controller
Above-GroundCylinders
Car Buffer
Plungers
Telescopic Holeless Hydraulic
Dimensions Passenger elevators
Rated lbs. 2000 2100 2500 3000 3500
Passenger Capacity1 13/12 13/12 16/15 20/18 23/21
Car2
Interior width 5-8 5-8 6-8 6-8 6-8
Interior depth 4-3 4-3 4-3 4-9 5-5
Interior height 8-0 (Optional 9-7 )
Car door width 3-0 3-0 3-6 3-6 3-6
Hoistway
Width (rise up to 30 ft 1 in) 7-4 7-4 8-4 8-4 8-4
Width (rise up to 30 ft 1 in) in seismic zones3 7-6 7-6 8-6 8-6 8-6
Width (rise over 30 ft 1 in) 7-10 7-10 8-10 8-10 8-10
Depth4 5-9 5-9 5-9 6-3 6-11
Rough opening width 4-8 4-8 5-2 5-2 5-2
Rough opening height 7-10 Clear opening height 7-0 (Optional 8-0 )
Clear overhead to hoist beam(rise up to 30 ft 1 in)
@ 100 ft/min 12-8
@ 125 ft/min 12-11
Clear overhead to hoist beam (rise over 30 ft 1 in)
@ 100 ft/min 13-0
@ 125 ft/min 13-2
Minimum pit depth5 4-0 (5-0 for Canadian Province of Ontario) to 7-6 depending on rise
Machine Room
Number of elevators in group 1 2 3 4Width x depth 5-9 x 7-4 11-6 x 8-6 17-0 x 8-6 22-0 x 8-6
L
A
B
C
D
E
F
G
H
I
J
K
1 Capacity code requirements: US/Canada.2 Interior dimensions may vary depending on interior finishes.3 In seismic zones 2 or greater.
4 For cars with front and rear doors add 9 14 to depth.5 Maximum rise with 4-0 pit depth is 34-4. Consult Otis.com or
your local Otis representative.
-
8/13/2019 Hydraulic Elevator Brochure
5/8
Travel Height
Maximum 60 ft
Maximum stops 7
Speed (ft/min) 100, 125, 150
Key Attributes
No need for well hole drilling and itsassociated costs
Above-ground solution substantially redrisk of soil and ground water contamina
Applicable for:
Hazard-sensitive sites
Waterfront sites
Existing buildings
Available in passenger elevatorconfigurations and capacities only
Solid-state starter improves performancthrough precise control of electric curre
Optional:
Front and rear entrances
Ceiling height of 9-7
8-0 clear opening
Glassback
REM remote elevator monitoring
Hoisting Beam(Not by Otis)
Plunger
MachineRoom
C
L
F
D
G
A
B
I H J
K
E
SECTION
PLAN
Car Buffer
Jack Stands
Ropes
Above-GroundCylinders
Plunger andPlunger Guides
Sheave
Fluid Tank/Controller
Governor
Roped Holeless Hydraulic
Dimensions Passenger elevators
Rated lbs. 2000 2100 2500 3000 3500
Passenger Capacity1 13/12 13/12 16/15 20/18 23/21
Car 2
Interior width 5-8 5-8 6-8 6-8 6-8
Interior depth 4-3 4-3 4-3 4-9 5-5
Interior height 8-0 (Optional 9-7 )
Car door width 3-0 3-0 3-6 3-6 3-6
Hoistway
Width 8-0 8-0 9-0 9-0 9-0
Width in seismic zones3 8-0 8-0 9-0 9-0 9-0
Depth4 5-9 5-9 5-9 6-3 6-11
Rough opening width 4-8 4-8 5-2 5-2 5-2
Rough opening height 7-10 Clear opening height 7-0 (Optional 8-0 )
Clear overhead to hoist beam
@ 100 ft/min 12-0
@ 125 ft/min 12-3
@ 150 ft/min 12-3
Minimum pit depth 4-0 (5-0 for Canadian Province of Ontario)
Machine Room
Number of elevators in group 1 2 3 4
Width x depth 5-9 x 7-4 11-6 x 8-6 17-0 x 8-6 22-0 x 8
L
A
B
C
D
E
F
G
HI
J
1 Capacity code requirements: US/Canada.
2 Interior dimensions may vary depending on interior finishes.
K
3 In seismic zones 2 or greater.
4 For cars with front and rear doors, add 9 14 to depth.
-
8/13/2019 Hydraulic Elevator Brochure
6/8
Well Hole(Required)
Hoisting Beam(Not by Otis)
Plunger
MachineRoom
F
D
G
A
B
C I H J
K
L
E
Cylinder withPVC Protection
Travel Height
Maximum 60 ft
Maximum stops 7
Speed (ft/min) 100, 125, 150
Key Attributes
Well hole drilling required
PVC protection surrounds wall and bottomof in-ground cylinder to prevent contact withunderground contaminants
Solid-state starter improves performancethrough precise control of electric current
Available in both passenger and serviceelevator configurations and capacities
Optional:
Front and rear entrances
Ceiling height of 9-7
8-0 clear opening
Glassback
REM remote elevator monitoring
SECTION
PLAN
Piston
Two CarBuffers
In-GroundCylinder
Fluid Tank/Controller
Holed Hydraulic
Double Bottom Cylinder With SealedPVC ProtectionOtis hydraulic systems feature sealed PVC protection
to diminish potential damage by corrosion. The in-
ground cylinders wall and bottom are surrounded
by PVC and sealed at the cylinder head.
Sealed PVC protection permits monitoring of the
space between the cylinder wall and the PVC lining.
Its evacuation port removes much of the unwanted
liquids that may collect between the PVC and cylinder.
Plunger
Cylinder
Plunger S top
Plate
Welds
Pressurized PortEvacuationPort
Cylinder Su pport Plate
Orifice
Safety Bulkhead
PVC Endcap
EvacuationTube
1 Capacity code requirements: US/Canada.
2 Interior dimensions may vary depending on interior finishes.
Dimensions Passenger elevators Service elevators
Rated lbs. 2000 2100 2500 3000 3500 4500 5000 5000 AIA
Passenger Capacity1 13/12 13/12 16/15 20/18 23/21 30/28 33/31 33/31
Car2
Interior width 5-8 5-8 6-8 6-8 6-8 5-8 5-11 5-8
Interior depth 4-3 4-3 4-3 4-9 5-5 7-11 8-6 9-0
Interior height 8-0 (Optional 9-7 )
Car door width 3-0 3-0 3-6 3-6 3-6 4-0 4-6 4-0
Hoistway
Width 7-4 7-4 8-4 8-4 8-4 7-5 8-2 7-5
Width in seismic zones3 7-6 7-6 8-6 8-6 8-6 7-7 8-4 7-7
Depth4 5-9 5-9 5-9 6-3 6-11 9-8 10-3 10-9
Rough opening width 4-8 4-8 5-2 5-2 5-2 5-8 6-2 5-8
Rough opening height 7-10 Clear opening height 7-0 (Optional 8-0 )
Clear overhead to hoist beam
@ 100 ft/min 12-0 12-0 12-0 12-0 12-0 12-0 12-5 12-0
@ 125 ft/min 12-3 12-3 12-3 12-3 12-3 12-3 12-8 12-3
@ 150 ft/min 12-3 12-3 12-3 12-3 12-3 12-3 12-8 12-3
Minimum pit depth 4-0 (5-0 for Canadian Province of Ontario)
Machine Room
Number of elevators in group 1 2 3 4
Width x depth 5-9 x 7-4 11-6 x 8-6 17-0 x 8-6 22-0 x 8-6
L
A
B
C
D
F
G
H
I
J
K
E
3 In seismic zones 2 or greater.4 For cars with front and rear doors, add 914 to depth for 2000 to
3500 lb. capacities; add 1214 for 4500 and 5000 lb. capacities.
-
8/13/2019 Hydraulic Elevator Brochure
7/8
Design professionals can choose from the industrys
broadest range of interior options. Theyll find Otis
long-term commitment to safety, durability and
quality reflected in all of our products.
Whether the most critical design criteria is aesthetics,
maximum durability or simply budgetary, theres a
wide selection to choose from.
Finishes and FixturesOtis broad array of options includes:
Frames and doors Car interiors
Car ceilings and lighting Handrails and bumpers
Car operating panels, hall lanterns, position
indicators, and other car and hall fixtures
Cab Ceilings
Standard Car and Hall Fixtures Classic Hall Fixtures
Handrails and Bumper RailsCab Walls
LexanSuspendedCeiling
EggcrateSuspendedCeiling
Vertical AppliedPanels
Flat Bar
Round Tubular
Hall Lantern
Hall ButtonIntermediate
Hall ButtonLobby Fixture
Hall Lantern/Position IndicatorIntermediate Landing
Hall LanternIntermediate
Hall PositionIndicator
Buttons withIlluminated Halo
Vandal-resistantButtons withIlluminated
Center Jewel
Buttons withIlluminated Halo
Vandal-resistantButtons withIlluminated
Center Jewel
Hall PositionIndicator
Hall Lantern/Position IndicatorIntermediate Landing
Solid BarHorizontalPanels
Car Operating Panel
Service Cabs
Hall Button
DownlightCeiling
-
8/13/2019 Hydraulic Elevator Brochure
8/8
www.ot is .com
HYD-1200 (0606)Otis Elevator Company 2006
All rights reserved