hwmnbtsemodules
DESCRIPTION
siemens btse modulesTRANSCRIPT
-
GERAN
Hardware
Base Transceiver Station Equipment
HWMN:BTSE Modules
A50016-G5100-A083-01-7620
-
2 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f1647
f Important Notice on Product Safety
DANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system must comply with the applicable safety standards.Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components may also have high operating temperatures.Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage.Therefore, only trained and qualified personnel may install and maintain the system.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
LEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Alle an das System angeschlossenen Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.In diesen Anlagen stehen die Netzversorgungsleitungen unter gefhrlicher Spannung. Einige Komponenten knnen auch eine hohe Betriebstemperatur aufweisen.Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Krperverletzungen oder Sachschden fhren.Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten.
Caution:
This equipment has been tested and found to comply with EN 301489. Its class of conformity is defined in table A30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accor-dance with the relevant standards referenced in the manual Guide to Documentation, may cause harmful inter-ference to radio communications.For system installations it is strictly required to choose all installation sites according to national and local require-ments concerning construction rules and static load capacities of buildings and roofs.For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagnetic field / force (EMF) limits. Otherwise harmful personal interference is possible.
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.
Copyright (C) Siemens AG 2006
Issued by the Communications GroupHofmannstrae 51D-81359 Mnchen
Technical modifications possible.Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.
Copyright (C) Siemens AG 2006
Issued by the Communications GroupHofmannstrae 51D-81359 Mnchen
Technical modifications possible.Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.
-
A50016-G5100-A083-01-7620
3
HWMN:BTSE Modules
Id:0900d805800f1647
Table of ContentsThis document has 209 pages.
Reason for Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.1 Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.2 Structure of the Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151.3 Rack Outlines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161.4 General Information on BTSE LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161.5 Removing and Inserting Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.1 A:COOLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202.2 A:DUAMCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.3 A:DUXMEG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.4 A:OVP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.5 A:TIFNTPM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.6 ABISCON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.6.1 M:ABISCON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.6.2 M:ABISCONCX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.7 AC/DC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332.7.1 AC/DCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342.7.2 AC/DCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362.7.3 AC/DCM-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372.7.4 AC/DC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382.7.5 ACPSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402.7.6 ACPSC/U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442.7.7 DCPSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442.8 ACPROTECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452.8.1 ACPROTECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462.8.2 ACPROTECT-2M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472.9 ACT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482.9.1 ACTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 492.9.2 ACTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502.9.2.1 ACTC12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502.9.2.2 ACTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512.9.2.3 ACTC-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522.9.2.4 M:ACTC-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 532.9.3 ACTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542.9.4 ACTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 552.10 AGENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 582.11 AGIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 632.11.1 M:AGINV1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 632.11.2 M:AGINV2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 642.11.3 M:AGINV3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652.12 BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 662.12.1 BCOMPG/BCOMD/BCOMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
-
4 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f1647
2.12.2 BCOM12PGV/BCOM12DV/BCOM12PV . . . . . . . . . . . . . . . . . . . . . . . . . . . 702.13 CCINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 742.14 COAMCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 772.15 COBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 802.15.1 M:COBA2P8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 812.15.2 M:COBA4P12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 872.15.3 M:COBAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 912.16 COREXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 972.17 COSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 982.17.1 M:COSA6P16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 982.17.2 M:COSA4P12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1022.18 CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1062.19 DCBCTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1102.19.1 DCBCTRLA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1112.19.2 DCBCTRLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1132.19.3 DCBCTRLM-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1162.19.4 DCBCTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1182.19.4.1 DCBCTRLV1V2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1182.19.4.2 DCBCTRLV3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1212.20 DCM-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1242.21 DCREFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1252.22 DCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1272.23 DIAMCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1312.23.1 DIAMCO V3V5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1332.23.2 DIAMCO V6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1352.24 DIPLEXER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1372.25 DPSK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1382.26 DUAMCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1392.26.1 DUAMCO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1432.26.2 DUAMCO4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1442.26.3 DUAMCO8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1452.27 DUBIAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1462.28 DUSTFILM-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1472.29 ECU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1482.30 FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1522.30.1 FANM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1532.30.2 FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1532.31 FDUAMCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1542.32 FICOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1592.32.1 FIPLUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1592.32.2 FIPLUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1622.33 FlexCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1662.34 FWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1702.35 GCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1712.36 HEATER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1752.36.1 HEATER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1762.36.2 HEATER-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
-
A50016-G5100-A083-01-7620
5
HWMN:BTSE Modules
Id:0900d805800f1647
2.36.3 HEATER-2DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1782.36.4 HEATER48/120/220/AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1782.36.5 HEATERM-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1782.37 HEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1792.38 HPDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1802.39 MEF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1822.39.1 MEF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1822.39.2 MEF150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1832.39.3 MEFM-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1842.40 OPEXAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1852.41 OVPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1872.41.1 M:OVPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1882.41.2 M:OVPTKOAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1902.41.3 M:OVPTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1922.41.4 M:OVPTCOAXM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1952.42 TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1972.42.1 TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1982.42.2 STMA/DTMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2002.43 TMB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
-
6 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f1647
List of FiguresFigure 1 Module Fastening Variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Figure 2 Location of the Plug-in Module Code Keys. . . . . . . . . . . . . . . . . . . . . . . 18Figure 3 Location of the Plug-in Module Code Key Number. . . . . . . . . . . . . . . . . 18Figure 4 A:COOLING: Configuration with 2 NTPMs and the A:DUAMCO . . . . . . 20Figure 5 A:DUAMCO: 4:1 and 2:1 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Figure 6 A:DUAMCO: DIP Switch (Factory Setting) . . . . . . . . . . . . . . . . . . . . . . . 23Figure 7 A:DUXMEG: Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 8 A:OVP: Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Figure 9 A:TIFNTPM: Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Figure 10 A:TIFNTPM: Mechanical Sketch Top View. . . . . . . . . . . . . . . . . . . . . . . 28Figure 11 A:TIFNTPM: Configuration with 2 NTPMs and the A:DUAMCO. . . . . . . 30Figure 12 ABISCON: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Figure 13 AC/DCA: Appearance and LED Indications . . . . . . . . . . . . . . . . . . . . . . 34Figure 14 AC/DCD: Appearance and LED Indications . . . . . . . . . . . . . . . . . . . . . . 36Figure 15 AC/DCM-2: Appearance and LED Indications . . . . . . . . . . . . . . . . . . . . 37Figure 16 AC/DC: Appearance and LED Indications . . . . . . . . . . . . . . . . . . . . . . . 38Figure 17 ACPSC/DCPSC: Appearance and LED Indications . . . . . . . . . . . . . . . . 40Figure 18 ACPSC: Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Figure 19 DCPSC: Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Figure 20 ACPROTECT: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Figure 21 ACPROTECT-2M: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Figure 22 ACT: Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Figure 23 ACTA: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Figure 24 ACTA: Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Figure 25 ACTC12: Appearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Figure 26 ACTC12: Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Figure 27 ACTC: Appearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Figure 28 ACTC: Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Figure 29 ACTC-3: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Figure 30 M:ACTC-4V1: Appearance (Front View). . . . . . . . . . . . . . . . . . . . . . . . . 53Figure 31 M:ACTC-4V1: Switch Locations (Top View) . . . . . . . . . . . . . . . . . . . . . . 53Figure 32 ACTM: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Figure 33 ACTP: Connector Locations (Horizontal DIP Switch Variant). . . . . . . . . 55Figure 34 ACTP: Connector Locations (Vertical DIP Switch Variant) . . . . . . . . . . . 56Figure 35 ACTP: DIP Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Figure 36 AGENT: with Indoor Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Figure 37 AGENT: with Outdoor Cover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Figure 38 AGENT: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Figure 39 LIPA: Appearance and Connector Locations . . . . . . . . . . . . . . . . . . . . . 60Figure 40 AGENT: Antenna Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Figure 41 AGENT: Antenna Connection with Internal Patch Antenna . . . . . . . . . . 61Figure 42 AGENT: Antenna Connection with Duplexer . . . . . . . . . . . . . . . . . . . . . 62Figure 43 AGINV1: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Figure 44 AGINV2: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Figure 45 AGINV3: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
-
A50016-G5100-A083-01-7620
7
HWMN:BTSE Modules
Id:0900d805800f1647
Figure 46 BCOMPG: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Figure 47 BCOMP: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Figure 48 BCOM12: Appearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Figure 49 BCOM12: Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Figure 50 CCINT: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Figure 51 COAMCO: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . . . 78Figure 52 COBA2P8: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . . . 81Figure 53 COBA2P8: DIP Switch Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84Figure 54 COBA2P8: DIP Switch Settings of Port 1 and Port 2. . . . . . . . . . . . . . . 85Figure 55 COBA2P8: DIP Switch Settings of External Clock Synchronization . . . 86Figure 56 COBA4P12: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . . 87Figure 57 COBA4P12: DIP Switch Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Figure 58 COBA4P12_Switch_ExternalClockSynchronization . . . . . . . . . . . . . . . 90Figure 59 COBAM: Interfaces and LED Indications. . . . . . . . . . . . . . . . . . . . . . . . 91Figure 60 COBAM: Location of DIP Switches S1 and S2 . . . . . . . . . . . . . . . . . . . 93Figure 61 COBAM: DIP Switch Settings of PCM Line . . . . . . . . . . . . . . . . . . . . . . 94Figure 62 COBAM: DIP Switch Setting PCM30 120 . . . . . . . . . . . . . . . . . . . . 94Figure 63 COBAM: DIP Switch Setting PCM30 75 . . . . . . . . . . . . . . . . . . . . . 94Figure 64 COBAM: DIP Switch Setting PCM30 100 . . . . . . . . . . . . . . . . . . . . 95Figure 65 COBAM: DIP Switch Settings of External Clock Synchronization . . . . . 96Figure 66 COREXT: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Figure 67 COSA6P16: Appearance and LED Indications . . . . . . . . . . . . . . . . . . . 99Figure 68 COSA: Location of DIP Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101Figure 69 COSA: DIP Switch Settings of Impedance . . . . . . . . . . . . . . . . . . . . . 102Figure 70 COSA4P12: Appearance and LED Indications (Front View) . . . . . . . . 103Figure 71 COSA4P12: Appearance (Top View). . . . . . . . . . . . . . . . . . . . . . . . . . 105Figure 72 CU: Appearance and LED Indications (Front View). . . . . . . . . . . . . . . 107Figure 73 DCBCTRLAV1: Interfaces and LED Indications . . . . . . . . . . . . . . . . . 111Figure 74 DCBCTRLDV*: Interfaces and LED Indications. . . . . . . . . . . . . . . . . . 113Figure 75 DCBCTRLM-2: Appearance and LED Indications . . . . . . . . . . . . . . . . 116Figure 76 M:DCBCTRLV1V2: Interfaces and LED Indications. . . . . . . . . . . . . 118Figure 77 DCBCTRLV1V2: DIP Switch Settings (Battery Capacity) . . . . . . . . 119Figure 78 DCBCTRLV1V2: DIP Switch Settings (Slot-ID) . . . . . . . . . . . . . . . . 120Figure 79 M:DCBCTRLV3: Interfaces and LED Indications. . . . . . . . . . . . . . . . . 121Figure 80 DCBCTRLV3: DIP Switch Settings (Battery Manufacturer) . . . . . . . . . 122Figure 81 DCBCTRLV3: DIP Switch Settings (Battery Capacity) . . . . . . . . . . . . 123Figure 82 DCBCTRLV3: DIP Switch Settings (Slot-ID) . . . . . . . . . . . . . . . . . . . . 123Figure 83 DCM-2: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Figure 84 DCREFE: Appearance and LED Indications . . . . . . . . . . . . . . . . . . . . 125Figure 85 DCU: Interfaces and LED Indications (Front View) . . . . . . . . . . . . . . . 128Figure 86 DCU: Appearance and Interfaces (Back Side) . . . . . . . . . . . . . . . . . . 129Figure 87 DIAMCO: DIP Switch Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132Figure 88 DIAMCO: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . . . 133Figure 89 DIAMCO V6: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . 135Figure 90 DIPLEXER: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . 137Figure 91 DPSK: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Figure 92 DUAMCO: DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
-
8 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f1647
Figure 93 DUAMCO 2: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . 143Figure 94 DUAMCO 4: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . 144Figure 95 DUAMCO 8: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . 145Figure 96 DUBIAS: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . 146Figure 97 DUSTFILM-2: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147Figure 98 ECU: Interfaces and LED Indications (Front View). . . . . . . . . . . . . . . . 149Figure 99 FANM: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Figure 100 FAN: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153Figure 101 FDUAMCO: Interfaces and LED Indications. . . . . . . . . . . . . . . . . . . . . 156Figure 102 FDUAMCO: DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157Figure 103 FDUAMCO and COAMCO: 8:2 Configuration . . . . . . . . . . . . . . . . . . . 158Figure 104 FIPLUB: Interfaces and LED Indications (Variant Example). . . . . . . . . 160Figure 105 FIPLUB: Interfaces and LED Indications (Variant Example). . . . . . . . . 161Figure 106 FIPLUX: Interfaces and LED Indications (Variant Example). . . . . . . . . 163Figure 107 FIPLUX: Interfaces and LED Indications (Variant Example). . . . . . . . . 164Figure 108 FlexCU: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . . . . . 167Figure 109 FWB: Appearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170Figure 110 GCU: Interfaces and LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . 172Figure 111 HEATER: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . 176Figure 112 HEATER-2: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . 177Figure 113 HEATERM-2V1: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178Figure 114 HEX: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179Figure 115 HPDU: Appearance and Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . 181Figure 116 MEF: Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182Figure 117 MEF150V4: Appearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Figure 118 MEFM-2: Appearance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184Figure 119 OPEXAL: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185Figure 120 OVPT: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188Figure 121 OVPT: Signals on Abis Interface Terminal Block for External Wiring . . 189Figure 122 OVPTKOAX: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . 190Figure 123 OVPTM: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . 192Figure 124 OVPTCOAXM: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . 196Figure 125 TMA: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198Figure 126 STMAE* / STMARE / STMA850: Appearance and Interfaces . . . . . . . 200Figure 127 STMAD: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . 200Figure 128 DTMADV1: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . 201Figure 129 DTMAV2: Appearance and Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . 201Figure 130 M:TMB-2V1: Connectors and Switches . . . . . . . . . . . . . . . . . . . . . . . . 203
-
A50016-G5100-A083-01-7620
9
HWMN:BTSE Modules
Id:0900d805800f1647
List of TablesTable 1 A:DUMACO: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 2 A:DUMACO: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 3 A:DUAMCO: DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Table 4 A:OVP: Interface Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Table 5 NTPMKU: Pin Assignment of the Terminal Block . . . . . . . . . . . . . . . . . 29Table 6 AC/DCA: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Table 7 AC/DCA: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Table 8 AC/DCDV1: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Table 9 AC/DCDV1: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Table 10 AC/DCDV1: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Table 11 AC/DCV1: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Table 12 ACPSC/DCPSC: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Table 13 ACPSC/DCPSC: Alarm Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Table 14 ACPSC: Assignment of PSC Connector . . . . . . . . . . . . . . . . . . . . . . . . 43Table 15 ACPSC: Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Table 16 M:ACTC-4V1: Switch Settings X24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Table 17 ACTP: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Table 18 ACTP: DIP Switch Settings: Cabinet Address . . . . . . . . . . . . . . . . . . . . 57Table 19 ACTP: DIP Switch Settings: Watchdog . . . . . . . . . . . . . . . . . . . . . . . . . 57Table 20 AGENT: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Table 21 AGENT: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Table 22 BCOM: LED Indications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Table 23 BCOM 6:6 Connector Assignment for Cell Configuration 2/2/2 . . . . . . . 68Table 24 BCOM 12:6 Connector Assignment for Cell Configuration 6/6/0 . . . . . . 71Table 25 CCINT: LED Indications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Table 26 CCINT: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Table 27 COAMCO: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78Table 28 COAMCO: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Table 29 COBA2P8: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Table 30 COBA2P8: Front Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Table 31 COBA2P8: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Table 32 COBA2P8: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Table 33 COBA4P12: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Table 34 COBA4P12: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Table 35 COBAM: LED Indications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Table 36 COBAM: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Table 37 COBAM: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Table 38 COSA6P16: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Table 39 COSA4P12: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Table 40 CU: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Table 41 CU: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Table 42 CU: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Table 43 DCBCTRLAV1: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111Table 44 DCBCTRLAV1: Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Table 45 DCBCTRLD: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
-
10 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f1647
Table 46 DCBCTRLD: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Table 47 DCBCTRLD: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115Table 48 DCBCTRLM-2: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Table 49 M:DCBCTRLV1V2: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . 119Table 50 DCBCTRLV1V2: DIP Switch Settings (Slot-ID). . . . . . . . . . . . . . . . . 120Table 51 DCBCTRLV3: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122Table 52 DCBCTRLV3: DIP Switch Settings (Battery Manufacturer) . . . . . . . . . 122Table 53 DCBCTRLV3: DIP Switch Settings (Slot-ID). . . . . . . . . . . . . . . . . . . . . 123Table 54 DCREFE: LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125Table 55 DCREFE: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126Table 56 DCU: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129Table 57 DCU: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130Table 58 DCU: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130Table 59 DIAMCO: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132Table 60 DIAMCO: DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132Table 61 DIAMCO V3V5: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Table 62 DIAMCO V6: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Table 63 DIPLEXER: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137Table 64 DPSK: Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Table 65 DUAMCO: LED Signalling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140Table 66 DUAMCO: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141Table 67 DUAMCO: DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141Table 68 DUBIAS: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146Table 69 ECU: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Table 70 ECU: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Table 71 ECU: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Table 72 DUAMCO / FDUAMCO Hardware Compatibility. . . . . . . . . . . . . . . . . . 155Table 73 FDUAMCO: LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157Table 74 DIAMCO: DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157Table 75 FIPLUB: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Table 76 FIPLUB: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Table 77 FIPLUX: LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165Table 78 FIPLUX: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165Table 79 FlexCU: LED Indications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168Table 80 FlexCU: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168Table 81 FlexCU: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169Table 82 GCU: LED Indications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173Table 83 GCU: Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173Table 84 GCU: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174Table 85 HEATERV1/V2: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176Table 86 HEATER-2V1: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177Table 87 HEATER--2DCV1: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178Table 88 HPDU: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181Table 89 OPEXAL: ACTM Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186Table 90 OPEXAL: Alarm Connector Block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186Table 91 OVPT: PCM Interface to the COBA/COSA (Soldering Side: 25 Pin Sub-D
Connector to EMI-Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
-
A50016-G5100-A083-01-7620
11
HWMN:BTSE Modules
Id:0900d805800f1647
Table 92 OVPT: Abis Interface to the BTSE External Cabling . . . . . . . . . . . . . . 189Table 93 OVPT: Monitoring Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189Table 94 OVPTKOAX: PCM Interface to the COBA/COSA (Soldering Side: 25 Pin
Sub-D Connector to EMI-Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190Table 95 OVPTKOAX: Abis Interface (PCM0, 75 ) . . . . . . . . . . . . . . . . . . . . . 191Table 96 OVPTKOAX: Abis Interface (PCM1, 75 , if installed) . . . . . . . . . . . . 191Table 97 OVPTKOAX: Monitoring Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 191Table 98 OVPTM: Monitoring Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193Table 99 OVPTM: Monitoring Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193Table 100 OVPTM: Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193Table 101 OVPTM: RS232/Wave Configuration Interface . . . . . . . . . . . . . . . . . 193Table 102 OVPTM: LMT Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194Table 103 OVPTM: Abis Interface to COBA/TIF. . . . . . . . . . . . . . . . . . . . . . . . . . 194Table 104 OVPTCOAXM: Connectors X13/14, X17/19 . . . . . . . . . . . . . . . . . . . . 196Table 105 OVPTCOAXM: Connectors X20/21, X18/22 . . . . . . . . . . . . . . . . . . . . 196Table 106 OVPTCOAXM: 4 Pin Terminal Block x6 . . . . . . . . . . . . . . . . . . . . . . . 196Table 107 OVPTCOAXM: Cable Connections for the Abis Interface . . . . . . . . . . 196Table 108 TMA: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198Table 109 TMA: Fault Propagations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198Table 110 DTMA: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201Table 111 DTMA: Fault Propagations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202Table 112 TMB: Connector Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204Table 113 TMB: Connector X5 Main Load Relay. . . . . . . . . . . . . . . . . . . . . . . . 204Table 114 TMB: Connector X7 Switching Signals for Heater and Fan. . . . . . . . 204Table 115 TMB: Test Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
-
12 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800a3ce0
Reason for Update
Reason for UpdateIssue History
Issue 01 for Release BR8.0 (2006/15/12)
AC/DCD (2.7.2)
Additional hardware: AC/DCDV2
Issue Date Summary
Issue history for this document with order number A30808-X3247-K83-*-7620
01 06/2002 New release
02 07/2002 Revised description: AC/DC, DCBP, DCBCTRL
03 09/2002 Extension due to additional hardware
04 11/2002 Extension due to additional hardware
05 05/2003 Extension due to additional hardware
06 07/2003 Extension due to additional hardware
07 12/2003 Extension due to additional hardware
08 02/2004 Extension due to additional hardware
09 04/2004 Extension due to additional hardware
10 08/2004 Extension due to additional hardware
11 11/2004 Extension due to additional hardware
12 01/2005 Extension due to additional hardware
13 04/2005 Extension due to additional hardware
14 07/2005 Extension due to additional hardware
15 09/2005 Minor changes
16 10/2005 Extension due to additional hardware: FDUAMCOV3
17 11/2005 Extension due to additional hardware: DTMADV2
18 03/2006 Additional hardware: M:ACTC-4V1, DCBCTRLDV3, DIAMCOV6, FDUAMCOREV3, OPEXAL10V1
Revised description: ACTP
Issue history for this document with order number A50016-G5100-A083-*-7620
01 11/2006 Extension due to additional hardware: HEATERV3, HEATER-2V3, AC/DCDV2, MEF150V4, ACDCM-2V2, ACDCM-2V3, ACDCM-2V4, M:TMB-2V1, HEATERM-2V1, ACPROT-2M/UV1, HPDU2DV2
Revised description: M:ACTC-4V1
-
A50016-G5100-A083-01-7620
13
HWMN:BTSE Modules Reason for Update
Id:0900d805800a3ce0
AC/DCM-2 (2.7.3)
Additional hardware: AC/DCM-2V2 Additional hardware: AC/DCM-2V3 Additional hardware: AC/DCM-2V4
ACPROTECT (2.8)
Additional hardware: ACPROT-2M/UV1
ACT (2.9)
Revised description: M:ACTC-4V1
HEATER (2.36)
Additional hardware: HEATERV3 Additional hardware: HEATER-2V3 Additional hardware: HEATERM-2V1
HPDU (2.38)
Additional hardware: HPDU2DV2
MEF (2.39)
Additional hardware: MEF150V4
TMB (2.43)
Additional hardware: M:TMB-2V1
-
14 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800a3ce0
Reason for Update
-
A50016-G5100-A083-01-7620
15
HWMN:BTSE Modules Introduction
Id:0900d80580059111
1 Introduction
1.1 Purpose of the ManualThe purpose of this document is to identify specific design and construction issues. The Hardware Manual Modules (HW:BTSE Modules) describes: The appearance The LED indications The adjustments The DIP switch settings
of the modules.
The Hardware Manual Modules contains all hardware components that are relevant for maintenance and installation according to the IMN, ITMN and MMN Manuals.
1.2 Structure of the ManualThe HW:BTSE manual is structured in the following way:1. Introduction - purpose and structure of the manual.2. Modules3. Abbreviations4. Index
Remark to Subchapter Modules
In order to find the correct module in this manual it is important to know that two different expressions exist for each module:1. Module Name2. Mnemonic of element (for ordering)
For example:
The alphabetical order of the subchapters in the chapter Modules is sorted in the first level by the module name and in the second level by the mnemonic.
The title of the subchapters returns the module name and the list below returns the mnemonic of the element.
Module Name Description Mnemonic of Element
COBA For micro BTS M:COBAM
DUAMCO Duplexer Amplifier Multicoupler 4:2 P-GSM 900
DUAMCO4G
A:DUAMCO Add-on device: DUAMCO 2:1 P-GSM 900
A:DUAMCO2MPG
FICOM Plus base 2:1 R-GSM 900 FIPLUB2R
FICOM Plus extension 2:1 GSM 1800 FIPLUX2D
-
16 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d80580059111
Introduction
1.3 Rack Outlines
1.4 General Information on BTSE LEDsThis book contains the common LED signal mechanisms of the BTSE boards. All the modules of the BTSE have LEDs to indicate their status, except BATTERY, DIPLEXER, DUBIAS, FAN, HPDU and TMA.
After the startup, a hardware test will be executed on each module of the BTSE. Detected hardware errors will be indicated by the flashing reset LED where the number of the failed test is binary coded in the flashing sequence. The test number is an 8-bit value where the LSB (Least Significant Bit) is transferred first and the MSB (Most Sig-nificant Bit) last.
General meanings of the LED color when the LED is on: Green: Hardware and software are O.K. Red: After reset, during software initialization (one for each processor) Yellow: Active module of redundant board
There are additional LEDs and further meanings specific to each type of module, these are described in the respective section. There are also LEDs which show the status of software. These are described in the following module descriptions.
Whenever useful, the position of the module is indi-cated in a sketch of the corresponding racks.
Generally, sketches of the BS-240 II will be shown as an example, using the following abbreviations: ER: Extension Rack BR: Base Rack SR: Service Rack
ER BR SR
-
A50016-G5100-A083-01-7620
17
HWMN:BTSE Modules Introduction
Id:0900d80580059111
1.5 Removing and Inserting ModulesThere are two variants for fastening modules in the subracks.
Some modules, e.g., the COBA and COSA, are equipped with a lever mechanism at their front panel. For removing or inserting these modules, they can be fastened / unfas-tened by swivelling the levers at the top and bottom edges of the module.
Other modules, e.g., the CU, DIAMCO, DUAMCO, FICOM, AC/DC, are fastened with TORX-headed knurled screws. Replacement of these modules requires special tools.
Figure 1 Module Fastening Variants
The TMA (Tower Mounted Amplifier) must be replaced complete with its housing (to be mounted on / unmounted from the mast).
The semi-rigid / flexi cables on the CU, DIAMCO, DUAMCO and FICOM must be fastened / unfastened with a torque spanner (2 sizes).
g It must be ensured that the modules are only replaced by modules with the same (or a compatible) HW and SW functional status!
Modules with switches or jumpers must be compared with the removed module for safety reasons.
The modules should be removed and inserted as fast as possible, in order to prevent reading in false module addresses from the CAN BUS.
lever mechanism in open position
push together
lever mechanism in locked position torx screw
-
18 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d80580059111
Introduction
Handling Modules with Code Keys
To prevent the installation of the modules at incorrect mounting positions, code keys are used on all relevant plug-in modules.
Figure 2 Location of the Plug-in Module Code Keys
In order to avoid module and backplane connector damage when modules are removed from / inserted into a base station frame, please observe the following:
In general, after having removed a module from a base station frame, please make sure that the modules code keys (at the rear connector terminals) are mechanically intact, and that a code key plug has not been torn out from its socket and is now jammed in the backplane.
When replacing a module, please make sure
That the code keys of the new module have the same setting as those of the old one (see figure below)
That all code keys (also those of the old module) are mechanically intact That a code key plug has not been torn out from its socket and is now jammed in the
backplane
Figure 3 Location of the Plug-in Module Code Key Number
When inserting a module, do not use excessive pressure.
Code Keys
2
code key number
-
A50016-G5100-A083-01-7620
19
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2 Modules
-
20 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.1 A:COOLINGThe A:COOLING add-on module dissipates heat coming from the combiner.
g If an A:TIFNTPM is used in direct connection with an A:DUAMCOM, they must be separated by an A:COOLING module to avoid overheating of the A:TIFNTPM module.
Without A:COOLING, temperatures within limits for the A:TIFNTPM module (max 55 C / 131 F) can no longer be guaranteed at external temperatures above 45 C / 113 F.
The module is fed by a 12 V power supply coming from A:TIFNTPM.
Use of module A:COOLING: Simultaneous application of module A:DUAMCO and A:TIFNTPM Sequence of the modules from bottom to top: A:DUAMCO, A:COOLING, up to 4
A:TIFNTPMs
g No matter whether A:DUAMCO2:1 or A:DUAMCO4:1 is used, the module A:COOL-ING must be inserted in any case.
Figure 4 A:COOLING: Configuration with 2 NTPMs and the A:DUAMCO
Types of A:COOLING
A:COOLINGV1 S30861-U2270-X
A:COOLINGV2 S30861-U2278-X
A:TIFNTPM
A:COOLING
A:DUAMCO
eMicroAdd-onMain Power
ATIF2
ATIF1
12 V forthe FAN
230 VPowerSupply
OUT
IN
-
A50016-G5100-A083-01-7620
21
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.2 A:DUAMCOThe A:DUAMCO (Add-on Duplex Amplifier Multicoupler) is a combining module with the following general functions: Duplexing of the RX and the TX path, to be fed to a common antenna Amplifying and splitting of the RX signal from the antenna to the CUs Coupling of the TX paths from several CUs to the antenna TMA (Tower mounted Amplifier) power supply Antenna monitoring
The A:DUAMCO has two different operating modes: The high amplifying AMCO mode The low amplifying MUCO mode for use with the tower-mounted amplifier (TMA) or
in a multicoupler cascade
The hybrid combining can be done with the add-on modules A:DUAMCO2Mx to combine 2 carriers and A:DUAMCO4Mx to combine 4 carriers.
Types of A:DUAMCO Frequency Range
A:DUAMCO2MPGV1 S30861-U2160-X DUAMCO 2:1 P-GSM 900
A:DUAMCO2MPSV1 S30861-U2320-X DUAMCO 2:1 shifted P-GSM 900
A:DUAMCO2MDV1 S30861-U2161-X DUAMCO 2:1 GSM 1800
A:DUAMCO2MPV1 S30861-U2162-X DUAMCO 2:1 GSM 1900
A:DUAMCO2MREV1 S30861-U2198-X DUAMCO 2:1 GSM-RE
A:DUAMCO4MPGV1 S30861-U2163-X DUAMCO 4:1 P-GSM 900
A:DUAMCO4MPSV1 S30861-U2321-X DUAMCO 4:1 shifted P-GSM 900
A:DUAMCO4MDV1 S30861-U2164-X DUAMCO 4:1 GSM 1800
A:DUAMCO4MPV1 S30861-U2165-X DUAMCO 4:1 GSM 1900
A:DUAMCO4MREV1 S30861-U2199-X DUAMCO 4:1 GSM-RE
-
22 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 5 A:DUAMCO: 4:1 and 2:1 Interfaces
1
2
3
4
off
on
on
on
DIP Switch Antenna connector
e.g., A:DUAMCO4M
CAN-Bus
RX connectors Antenna connector TX connectors
LEDs, meaning see below
Testout connector
DIP Switch, setting see below. The DIP Switch
LEDs, meaning see below
e.g., A:DUAMCO2M
RX connectors TX connectors
CAN-Bus
position of a A:DUAMCO 2:1 is different.
-
A50016-G5100-A083-01-7620
23
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Switch
Figure 6 A:DUAMCO: DIP Switch (Factory Setting)
The switch setting for A:DUAMCO is described in Table 3.
g In BR 5.5 there is no use of TMA with BS-82 eMicro, so switch 1 must be set to off!
LED Signal Meaning
TMA Off Module is in AMCO mode
Green Module is in MUCO mode, TMA-DC is OK
Red Module is in MUCO mode, TMADC is not OK This LED is on for 5 sec. only.
ALAMRM The VSWR is above the threshold.
RESET The module is in reset.
POWER The DC power is present.
Table 1 A:DUMACO: LED Indications
Connector Meaning
RX 0...3 RX-output 0...3
The A:DUAMCO 4:1 provides 4 RF output ports for the RX signals for connection with module DCU: RX-input.
TX 0...3 TX-input 0...3
The DUAMCO 4:1 provides 4 TX-input ports for the TX signals for connection with module DCU: TX-output.
Testout RF Test Signal Output
SMA female connector is provided for RF test purposes
ANT Antenna Output
Output for antenna connection
CAN Bus Interface Power supply/CAN bus (broadband cable). The A:DUAMCO provides a CAN bus interface at the backplane connector for the controlling/monitoring signals.
Table 2 A:DUMACO: Connectors
1 2 3 4
off off off on
-
24 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
The setting of the switches 2 - 4 determines the attenuation at the A:DUAMCO. The total attenuation of cable (between TMA and A:DUAMCO) and DIP switch must be 6dB.
"X": any position allowed.
g Switch 1 does not work when a TMA alarm is present.
Function Switch 1 Switch 2 Switch 3 Switch 4
TMA off / AMCO mode Off X X X
TMA on / MUCO mode On X X X
Attenuator LNA 0 dB Off X X X
Attenuator LNA 0 dB On Off Off Off
Attenuator LNA 1 dB On On Off Off
Attenuator LNA 2 dB On Off On Off
Attenuator LNA 3 dB On On On Off
Attenuator LNA 4 dB On Off Off On
Attenuator LNA 5 dB On On Off On
Attenuator LNA 6 dB On Off On On
Attenuator LNA 7 dB On On On On
Factory setting Off Off Off On
Table 3 A:DUAMCO: DIP Switch Settings
-
A50016-G5100-A083-01-7620
25
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.3 A:DUXMEGThe A:DUXMEG (Add-on Duplex Filter for E-GSM) is a duplexer for the E-GSM 900 fre-quency range with the following general functions: Coupling of the transmitting path (TX) from the DCURGs to the antennas Splitting the receiving path (RX) from the antennas to the DCURGs
If the E-GSM 900 frequency band is to be provided, the duplexers will not be part of the DCU modules. Due to their large volume, the E-GSM 900 duplexers are configured as add-on modules (A:DUXMEG) on top of the base unit and a DCURG module is used as carrier unit. The combination of DCURG and DUXMEG has the same function as a single DCUDUX in other frequency ranges.
The TX outputs and the RX inputs of the DCURG are connected to A:DUXMEG via semi-rigid cables. The antenna output cables from A:DUXMEG run over the backplane and leave the eMicro at the bottom.
Up to 2 A:DUXMEG add-on modules can be installed at the top of the respective master cabinet as well as the optional extension cabinet.
Figure 7 A:DUXMEG: Interfaces
Types of A:DUXMEG
A:DUXMEGV1 S30861-U2176-X
TX input/female CU0
TX input/female CU1
antennaoutput CU1
antennaoutput CU0
RX output/male CU1
RX output male CU0
-
26 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.4 A:OVPThe A:OVP (Add-on Overvoltage Protection) is a lightning protection module for 16 Environmental Alarm (ENVA) lines.
The A:OVP16AM does not need any power supply and there is no PID EEPROM on it. The module name and the serial number are printed on a bar code label only.
The 16 alarm lines and 16 ground lines are connected to an external connector field using a cable containing 16 twisted-pair wires.
The 16 alarm lines are guided through the flash duct to the A:OVP16AM. Two alarm lines are connected to one overvoltage protector module, the two ground lines are tied together to the ground pin of the module.
Figure 8 A:OVP: Interfaces
Types of A:OVP
A:OVP16AM S30861-U2139-X
Signal Overvoltage Protector Signal
AL0_IN 1-1 5-1 AL8_IN
AL1_IN 1-2 5-2 AL9_IN
AL2_IN 2-1 6-1 AL10_IN
AL3_IN 2-2 6-2 AL11_IN
AL4_IN 3-1 7-1 AL12_IN
AL5_IN 3-2 7-2 AL13_IN
AL6_IN 4-1 8-1 AL14_IN
AL7_IN 4-2 8-2 AL15_IN
Table 4 A:OVP: Interface Assignment
-
A50016-G5100-A083-01-7620
27
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.5 A:TIFNTPMA:TIFNTPM (Terrestrial Interface for Network Termination Primary Access Multiplex) is an add-on module containing either an NTPMGF or an NTPMKU module, to be used as Abis interface (in the connection between BTS and BSC).
The NTPM is not part of A:TIFNTPM but it will be supplied by the provider as a termina-tion for the PCM 30 lines.
Figure 9 A:TIFNTPM: Interfaces
Types of A:TIFNTPM
A:TIFNTPM S30861-U2200-X
Plug to CORE BP terminal block 12V toA:COOLING
HeaterCabling
U Interface(Abis) cabling
M:NTPMCON
-
28 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 10 A:TIFNTPM: Mechanical Sketch Top View
If other add-on modules are mounted above A:TIFNTPM, they have to be removed in order to allow the substitution of an NTPM. The NTPM is inserted into the A:TIFNTPM from above with its front panel on the front side of the eMicro BTS.
g If an A:TIFNTPM is used in direct connection with an A:DUAMCOM, they must be separated by an A:COOLING module to avoid overheating of the A:TIFNTPM module.
The Abis interface cables must be routed through the flash duct.
In case of NTPMGF, the two glass fibres are connected to a special interconnection box at the NTPMGF module.
In case of NTPMKU the copper wires are connected at a terminal block according to the following table:
NTPM
6
1
6
1
M:ATIFCON Temperature switchBS = Backplane SideMIS = Module Insertion SideFS = Front Side
Plug to CORE BP Plug to cascaded NTPM
terminal block 12V to A:COOLING
HeaterCabling
U Interface(Abis) cabling
FAN
MIS
terminal block in case of NTPMKUAdditional box in case of NTPMGF
Additional box for the fibre optics
terminal blockfor UK
LED and test outputs
Plug toNTPMCON
Plug toM:ATIFCON
M:NTPMCON
FAN connection
AMP plug for UK2TemperatureSensor
-
A50016-G5100-A083-01-7620
29
HWMN:BTSE Modules Modules
Id:0900d805800f164a
If two A:TIFNTPMs are used, they need not necessarily be placed over one another. The two modules have to be directly connected to the two ATIF ports on the backplane of the eMicro BTS, each by means of a 40-wire flat ribbon cable (up to 80 cm / 31.5 inches long) terminated on both sides with BK-MOD plugs, to be inserted respectively into the ATIF port and the input/lowermost socket on the corresponding M:ATIFCON.
In order to manage the cables as easily as possible, the lowermost A:TIFNTPM should be bridged to ATIF1, the uppermost one to ATIF2.
Pin Signal
Pin 1 UK2out_b
Pin 2 UK2out_a
Pin 3 Ground
Pin 4 not used
Pin 5 UK2in_a
Pin 6 UK2in_b
Table 5 NTPMKU: Pin Assignment of the Terminal Block
-
30 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 11 A:TIFNTPM: Configuration with 2 NTPMs and the A:DUAMCO
A:TIFNTPM
A:TIFNTPM
A:COOLING
A:DUAMCO
eMicro
TIF Connection NTPM up to80 cm / 31.5 inches
ATIF1
ATF2 Add-on Main Power
230 VPowerSupply
12 V forthe FAN
OUT
INM:TIFCON
OUT
IN
-
A50016-G5100-A083-01-7620
31
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.6 ABISCON
Alternatively, the BTSE may be equipped with an OVPT interface module instead of the ABISCON, or both interface module types are omitted. In the latter case, the Abis lines are connected directly to the BTSEs EMI-Panel via a 25 pin Sub-D connector.
The ABISCON (Abis Connector) is an optional inter-face module with the following general functions: Easy connection of PCM (Abis) lines to the BTSE Provision for connecting external monitoring
equipment without interruption. The lines are decoupled by resistors in order to avoid interfer-ences.
Depending on the BTSE type, up to 2 ABISCON inter-face modules may be installed in order to handle up to 8 Abis ports (4 ports per ABISCON). At the EMI-Panel of the BS-240XS Base Rack, only one Abis connector module can be installed.
Types of ABISCON
M:ABISCON S30861-Q2189-X 100/120 symmetrical lines
M:ABISCONCX S30861-Q2190-X 75 coaxial lines
ER BR SR
inside EMI-Panel
-
32 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.6.1 M:ABISCON
Figure 12 ABISCON: Appearance
M:ABISCONV1 offers up to 4 Abis connections on a twisted pair cable terminal.
For connector layout and signal assignment, please refer to chapter M:OVPT.
2.6.2 M:ABISCONCXM:ABISCONV1 offers up to 4 Abis connections on an SMA connector terminal.
For connector layout and signal assignment, please refer to chapter M:OVPTKOAX.
-
A50016-G5100-A083-01-7620
33
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.7 AC/DC
AC/DC is a power supply module which provides all -48 V direct current consumer loads within the BTSE.
Types of AC/DC
AC/DCA S30861-U4093-X
AC/DCD S30861-U4102-X
AC/DCM-2 S30861-U2389-X
AC/DC S30861-U2008-X
ACPSC
ACPSC/U S30861-S2118-X
DCPSC S30861-U2254-X
ER BR SR
-
34 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.7.1 AC/DCA
For primary voltage of 230 V AC 50/60 Hz and DC output voltage of -48 V.
Figure 13 AC/DCA: Appearance and LED Indications
Types of AC/DCA
AC/DCAV1 S30861-U4093-X
Test SocketsLEDs
-
A50016-G5100-A083-01-7620
35
HWMN:BTSE Modules Modules
Id:0900d805800f164a
LEDs
Connectors
LED Signal Meaning
FF Red Fan Fail
OV Red Over Voltage
TC Yellow Terminal Control
IP Green Input Healthy
CL Red Current limit
OT Red Over Temperature
SB Yellow Standby
OI Green Output Current Healthy
OP Green Output Healthy
Table 6 AC/DCA: LED Indications
Connector Meaning
+I, -I Test Sockets for Output Current
Table 7 AC/DCA: Connectors
-
36 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.7.2 AC/DCD
For primary voltage of 230 V AC 50/60 Hz and DC output voltage of -48 V.
Figure 14 AC/DCD: Appearance and LED Indications
Types of AC/DCD
AC/DCDV1 S30861-U4102-X
AC/DCDV2 S30861-U4304-X
LED Signal Meaning
AC ON Green AC Input Power present
CL Yellow Current Limit
RFA Red Rectifier Fail
Table 8 AC/DCDV1: LED Indications
Switch Meaning
AC AC main switch
Table 9 AC/DCDV1: Switches
Connector Meaning
I-,I+ Test Sockets for Output Current
Table 10 AC/DCDV1: Connectors
AC Switch
AC ON
CL
RFA
Test Sockets
-
A50016-G5100-A083-01-7620
37
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.7.3 AC/DCM-2The tasks of the AC/DC rectifier of eMicro II are: Supply of all -48 V consumers within the BTSE Generating of alarms in case of AC mains or module failures
Figure 15 AC/DCM-2: Appearance and LED Indications
Types of AC/DCM-2
AC/DCM-2V1 S30861-U2389-X
AC/DCM-2V2 S30861-U2419-X
AC/DCM-2V3 S30861-U2464-X
AC/DCM-2V4 S30861-U2483-X mandatory for 7 Ah battery pack
INPUT OK
OUTPUT OK
The LEDs are off, if the internal supply voltage is down
-
38 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.7.4 AC/DC
For primary voltage of 230VAC 50/60Hz and DC output voltage of -48 V.
Figure 16 AC/DC: Appearance and LED Indications
Types of AC/DC
AC/DCV1 S30861-U2008-X
AC Input
Test Connector
Fuses 10A(quick acting)
LED
-
A50016-G5100-A083-01-7620
39
HWMN:BTSE Modules Modules
Id:0900d805800f164a
LED Signal Meaning
ON Green Rectifier OK
Pale green Rectifier OK, but low output voltage (caused by Remote_Off from controller)
Orange Power limit active
Red Output short circuit, unit faulty or overtemperature
Table 11 AC/DCV1: LED Indications
-
40 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.7.5 ACPSC
The module ACPSC has to be used for AC power supply, the module DCPSC has to be used for DC power supply. Backup battery is only possible for ACPSC!
The front sides of the modules ACPSC and DCPSC have the same design and func-tional units (breakers, reset, LEDs).
Figure 17 ACPSC/DCPSC: Appearance and LED Indications
Types of ACPSC
ACPSCV1 S30861-U2156-X
ACPSCV2 S30861-U2348-X
LED Signal Meaning
AC Green Primary power source present. The LED is on if the alarm MBR is not activated.
The LED is off in case of DCPSC.
DC Green DC output voltage within specified tolerance. The LED is on if the alarm 48OTB is not activated; the LED is off if the internal supply voltage of the controller board is down.
Table 12 ACPSC/DCPSC: LED Indications
RESET
Breakers
COBA, DCU 0
DCU 1
Add-on modules
External equipment
BAT FAILRESETAC OK
TEMP FAILHW/SW OKDC OK
-
A50016-G5100-A083-01-7620
41
HWMN:BTSE Modules Modules
Id:0900d805800f164a
ACPSC and DCPSC have different backplanes, but the connector pinning is the same.
Figure 18 ACPSC: Interfaces
HW/SW OK
Green Startup and selftest of PSCV1 finished and OK
BAT FAIL Red Battery system or temperature sensor on battery system is faulty. The LED is on if the alarms BAT_FAIL and/or TEMP_SENSE_FAIL are activated.
The LED is off in case of DCPSC.
TEMP Red Over- / Undertemperature protection. The LED is on if the over- or undertemperature protection is triggered.
RESET Red During RESET this LED is active. After Power On of the AC/DC controller this LED is on. In case the microcontroller has come into normal operation (is able to re-trigger watchdog and activate the CAN Bus interface), the LED goes off.
LED Signal Meaning
Table 12 ACPSC/DCPSC: LED Indications
ACPSC backplane side PID
AC power input
Connector for HEATER
Main Switch (not for ACPSCV2)DC external
Connector forBATTERY
Connector for COBA, DCU 0, DCU 1,Add-on modules
Connector Backplane Alarms
Connector ENVA BTS
MUE (-)PUE (+)
L1NPE
-
42 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 19 DCPSC: Interfaces
DC import
Main Switch
Connector for HEATER
PUE (+)MUE (-)
PID
DC external
Connector for COBA, DCU0, DCU1,Add-on modules
Connector Back-plane Alarms
ConnectorENVA BTS
Name Meaning
AUX0 DC-Output: 0V Pin for AUX48V auxiliary DC supply voltage and refer-ence potential for all control signals below
AUX48V DC-Output: Auxiliary 48 V DC supply voltage (48 V 20%; 250 mA max)
R_OK Alarm Output: This output signals two alarm situations (see figure above):Switches S1 and S2 are normally closed.S1 has to be opened in case AC/DC rectifier module faulty and the rectifier is unable to supply the specified power. This may happen in case of low input voltage, control circuit of DC voltage, current/power limiter are faulty, overtemper-ature protection or any other internal protections are active. S2 has to be opened in case AC input voltage is low.
R_OFF Control Input: In case voltage applied 0.8V or input left open: normal operation. In case voltage applied 3.5 V, AC/DC shuts down output. Input resistance 10k.
Vadj Control Input: Input signal to control DC output voltage of AC/DC rectifier according to Uo Control on Vadj.
Table 13 ACPSC/DCPSC: Alarm Assignment
-
A50016-G5100-A083-01-7620
43
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Signal Pin Pin Signal
PUE (0V) (20A) A1 9 n.c.
n.c. 1 10 n.c.
R_off (10mA) 2 11 n.c.
Vadj (10mA) 3 12 n.c.
AUX48V (10mA) 4 13 n.c.
AUX0V (250mA) 5 14 n.c.
OK (1mA) 6 15 Sense -(10 mA)
n.c. 7 A2 MUE (-48 V) (20 A)
Sense +(10mA) 8
Table 14 ACPSC: Assignment of PSC Connector
Alarm Meaning
MBR Mains Breakdown Alarm has to be activated if the AC/DC goes into a mains breakdown condition (voltage below limit).
BBR Battery Breakdown Alarm has to be activated if the battery voltage is below -43V0.5V
BCHF AC/DC rectifier module failure. Alarm has to be activated if the AC/DC is unable to supply the specified power. This may happen in case rectifier module is faulty, low input voltage, control circuit of temperature dependent nominal voltage, current/power limiter are faulty, overtemperature protection or any other internal protections are active.
48 OTB DC-Output Voltage on the load out of specified tolerance. Alarm has to be activated if the output voltage is out of spec-ified range of -39.5V...-56.7V or the voltage control loop is faulty. The alarm must not be triggered during Backup Oper-ation.
BAT_FAIL This alarm has to be activated in case the battery monitoring unit has found that the capacity of the battery is below a specified limit as a result of the battery test.
OVER_TEMP Alarm has to be activated in case of overtemperature
UNDER_TEMP Alarm has to be activated in case of undertemperature
BAT_DISCHARGE This alarm has to be activated in case the AC/DC system comes into backup operation (battery supplies load); this alarm must not be triggered during battery test.
TEMP_SENSE_FAIL This alarm has to be activated in case the resistance value of the temperature sensor of Battery 0 is out of the speci-fied range.
Table 15 ACPSC: Alarms
-
44 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.7.6 ACPSC/U
AC power supply and control unit for 115 V (eMicro BTSE).
Difference from ACPSC: no main switch the L1/N-connection of the AC power input is changed.
g For ACPSC/U a Field Wiring Box or ACPROTECT is needed. See chapters FWB or ACPROTECT.
2.7.7 DCPSC
See also chapter ACPSC.
Types of ACPSC/U
ACPSC/UV1 S30861-U2235-X
Types of DCPSC
DCPSCV3 S30861-U2254-X
-
A50016-G5100-A083-01-7620
45
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.8 ACPROTECTThe ACPROTECT (AC Input Lightning Protection) is installed as external unit to the BS-82 II cabinet to ensure lightning protection of the BTS subsystem. The ACPROTECT box also includes an AC breaker. The distance between ACPROTECT box and the BS-82 II cabinet shall not exceed 1.8 m. The AC supply cable for the cabinet is part of the ACPROTECT box.
Types of ACPROTECT
ACPROTECT
ACPROTECTV1 S30861-U2239-X
ACPROTECTV2 S30861-U2257-X
ACPROTECTV3 S30861-U2293-X
ACPROTECT-2M
ACPROTECT-2MV1 S30861-U2418-X
ACPROT-2M/UV1 S30861-U2455-X
-
46 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.8.1 ACPROTECT
Figure 20 ACPROTECT: Appearance
1) 2) 3)
7)
5)
6)
4) bottom
Note:1) ACmains supply2) grounding cable3) AC cable to BTS (protected)4) recommended mounting position5) ground bolt6) PE/N/L1 (in)7) PE/N/L1 (out)
-
A50016-G5100-A083-01-7620
47
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.8.2 ACPROTECT-2M
Figure 21 ACPROTECT-2M: Appearance
-
48 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.9 ACT
ACTC is part of the DC Panel in every rack. Each ACTC provides 16 alarms. The ACTC in the Base Rack is directly connected to the COBA, in every other rack it is connected to ACTP.
ACTP provides a connection to the COBA via the CAN BUS.
ACTM optionally provides 48 additional alarms and 8 outputs at the Base Rack. It is directly connected to the CAN BUS.
g The ACTM module consists of an ACTA (ACT-Alarm) and an ACTP module, which are directly plugged together. The ACTM must be replaced es a whole unit because the Product Identification Data of the whole unit is stored into the ACTP.
Internal and external alarms of all racks are collected by ACT (Alarm Collection Terminal) modules and channeled to the COBA in the Base Rack.
There are three types of ACT modules: ACTC (ACT-Connection) is the standard alarm
connection module. ACTP (ACT-Processor) is the CAN BUS inter-
face for the alarm connection modules. ACTM (ACT-Master) is an optional alarm con-
nection module for the Base Rack.
Types of ACT
ACTA: (Part of ACTM)
ACTAV2 S30861-Q2053-X
ACTC:
ACTC12V1 S30861-Q2138-X
ACTCV1 S30861-Q2029-X
ACTC-3V1 S30861-Q2194-X
ACTC-4V1 S30861-Q2267-X
ACTP:
ACTPV2 S30861-Q2052-X
ACTPV3 S30861-Q4088-X
ACTM:
ACTMV2 S30861-U2079-X
ER BR SR
ACTM inside EMI-Panel
-
A50016-G5100-A083-01-7620
49
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Figure 22 ACT: Configurations
Some units have an independent access to the CAN BUS, e.g., DUAMCO and FICOM
2.9.1 ACTAFor base rack: part of ACTMV2
Figure 23 ACTA: Appearance
Base Rack Extension Rack Service Rack
ACTC ACTM
COBACAN BUS
ACTC
ACTP
ACTC
ACTP
(optional)
-
50 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 24 ACTA: Connector Locations
g In case of alarm signal modifications, please refer to the respective base station installation manual (IMN) for more information on the alarm signal assignment.
2.9.2 ACTC
2.9.2.1 ACTC12
Figure 25 ACTC12: Appearance
X1
X9
X8
X10
X6X7 X5
X4 X2X3
-
A50016-G5100-A083-01-7620
51
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Figure 26 ACTC12: Connector Locations
g In case of alarm signal modifications, please refer to the respective base station installation manual (IMN) for more information on the alarm signal assignment.
2.9.2.2 ACTC
Figure 27 ACTC: Appearance
Alarm_IN
Temperature Sensors
116
BB0 BB1 BB2
SMOKE RDO SIS
HHHX X X0 1 2
WWW
1 2 3
W4
W5
W6
W7
W8
W9
BB3
-
52 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 28 ACTC: Connector Locations
g In case of alarm signal modifications, please refer to the respective base station installation manual (IMN) for more information on the alarm signal assignment.
2.9.2.3 ACTC-3
Figure 29 ACTC-3: Appearance
g In case of alarm signal modifications, please refer to the respective base station installation manual (IMN) for more information on the alarm signal assignment.
Alarm_IN
Temperature Sensor
124
BB0 BB1 BB2
SMOKE RDO SIS
HHHX X X0 1 2
WWW
1 2 3
W4
W5
W6
W7
W8
W9
Temperature Sensors
SMOKEsmoke sensor
RDOrack door open
24
Environmental Alarms
1
-
A50016-G5100-A083-01-7620
53
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.9.2.4 M:ACTC-4
Figure 30 M:ACTC-4V1: Appearance (Front View)
g In case of alarm signal modifications, please refer to the respective base station installation manual (IMN) for more information on the alarm signal assignment.
Figure 31 M:ACTC-4V1: Switch Locations (Top View)
Switches
Jumper X24
ON MAJor alarm is activated, occupying Alarm12, which is therefore not available on connection block X4. (dafault for service 1A cabinets)
OFF MAJor alarm is deactivated, Alarm12 is available on connection block X4. (dafault for all other cabinets)
Table 16 M:ACTC-4V1: Switch Settings X24
-
54 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.9.3 ACTMFor base rack: consists of ACTA and ACTP
Figure 32 ACTM: Appearance
ACTA
ACTP
ACTA
ACTP
-
A50016-G5100-A083-01-7620
55
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.9.4 ACTPFor extension and service rack/shelter
There are two DIP switch variants on the ACTP with either a horizontal arrangement (Figure 33) or a vertical arrangement (Figure 34) of the switches.
Figure 33 ACTP: Connector Locations (Horizontal DIP Switch Variant)
X6
X2 (opposite side)
X4
LEDs
Reset
X5 (opposite side)
DIP Switch
-
56 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 34 ACTP: Connector Locations (Vertical DIP Switch Variant)
LED Color Meaning
Green Hardware and Software are O.K. (tests successfully passed)
Red The microcontroller is resetting
Table 17 ACTP: LED Indications
X6
X2 (opposite side)
X4
LEDs
Reset
X5 (opposite side)
DIP Switch
-
A50016-G5100-A083-01-7620
57
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Switch
The rack address is preset in the factory for the base rack, the extension rack 1, and the service rack 1. Additional racks require a setting on site.
Figure 35 ACTP: DIP Switch
Rack/Shelter
No. Type Switch 1 Switch 2 Switch 3
0 Base OFF / OPEN OFF / OPEN OFF / OPEN
1 Extension 1 ON / CLOSED OFF / OPEN OFF / OPEN
2 Extension 2 OFF / OPEN ON / CLOSED OFF / OPEN
3 Service 1 ON / CLOSED ON / CLOSED OFF / OPEN
4 Service 2/1A OFF / OPEN OFF / OPEN ON / CLOSED
5 Service 2 ON / CLOSED OFF / OPEN ON / CLOSED
6 Service 2 OFF / OPEN ON / CLOSED ON / CLOSED
7 Service 2 ON / CLOSED ON / CLOSED ON / CLOSED
Table 18 ACTP: DIP Switch Settings: Cabinet Address
Watchdog Switch 4
Enable (default) ON / CLOSED
Disable OFF / OPEN
Table 19 ACTP: DIP Switch Settings: Watchdog
ON
1 432
ON
OFF
1 432
OPEN
CLOSED
Settings for Base Rack
Vertical Type:
Horizontal Type:
OPEN
-
58 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.10 AGENTThe BS-242 AGENT is a compact transceiver unit. Up to 24 AGENTS can be connected to a BS-242 SERVER.
g Not part of BR8.0 and above
All tables and descriptions in this chapter are valid for all AGENTs above.
Figure 36 AGENT: with Indoor Cover
Types of AGENTs
R:AGENPGV1 S30861-C2008-X P-GSM 900
R:AGENPDV1 S30861-C2009-X GSM 1800
-
A50016-G5100-A083-01-7620
59
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Figure 37 AGENT: with Outdoor Cover
AGENT LEDs, Test Connector, PID Connector:
The agent LEDs, a test connector and a PID connector can be accessed after removing a small cover plate located at the bottom of the agent.
Figure 38 AGENT: LED Indications
LED Signal Meaning
OK Green Ready for operation
SW Green Software-specific
RES Red Agent in reset state
PA Red Power amplifier alarm
Table 20 AGENT: LED Indications
OK SW
RES PA
-
60 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 39 LIPA: Appearance and Connector Locations
Connector Meaning
TAD Test adapter
CCSLink Server connection via LIPAGE junction box
RX Internal AGENT receiver part connector to IPA / Duplexer
TX Internal AGENT transmitter part connector to IPA / Duplexer
Table 21 AGENT: Connectors
D2-b
D2-a
D1-b
D1-a
GN
D
Server side
Agent side
whiteblackredblackscreen
-
A50016-G5100-A083-01-7620
61
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Antenna Features
The agent may be equipped either with an internal patch antenna (IPA), or with a duplexer for connection to an external antenna.
Figure 40 AGENT: Antenna Connectors
Figure 41 AGENT: Antenna Connection with Internal Patch Antenna
One female SMA connector is the interface for connecting an external TX/RX antenna, if the agent is equipped with a duplexer (DUPLP).
ANT RX ANT TX
INTERNAL PATCH ANTENNA
-
62 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 42 AGENT: Antenna Connection with Duplexer
ANT TX/RXDUPLEXER
-
A50016-G5100-A083-01-7620
63
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.11 AGINThe AGIN (Agent Interface) is an overvoltage protection and interface module for the connection of BS-242 AGENTs to the SERVER.
g Not part of BR8.0 and above
Depending on the number of agents installed, one or two agent interface (AGIN) modules are installed (AGIN 0: AGENT 0 .. 11; AGIN 1: AGENT 12 .. 23). For checking the order of the cabling refer to IMN:BTSE BS-242 Pico.
The following pictures show the respective AGIN module versions.
2.11.1 M:AGINV1
Figure 43 AGINV1: Appearance
Types of AGIN
M:AGINV1 S30861-Q2081-X
M:AGINV2 S30861-Q2153-X
M:AGINV3 S30861-Q2183-X
-
64 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.11.2 M:AGINV2
Figure 44 AGINV2: Appearance
-
A50016-G5100-A083-01-7620
65
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.11.3 M:AGINV3
Figure 45 AGINV3: Appearance
-
66 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.12 BCOMThe BCOM (Basic Combining Equipment) consists of six identical combining modules (0-5) in a shared case. Each of these modules has the following general functions: Duplexing of the RX and the TX path, to be fed to a common antenna Amplifying and splitting of the RX signal from the antenna to the CUs Coupling of the TX paths from several CUs to the antenna
For the receive path, the BCOM provides a gain of 20 dB +/- 1.5 db (ANT - RX).
There is one LED at the front panel:
Types of BCOM
Basic Combiner 6:6 with 6 antenna interfaces for 6 carriers
BCOMPGV1 S30861-U2338-X P-GSM 900
BCOMDV1 S30861-U2339-X GSM 1800
BCOMPV1 S30861-U2340-X GSM 1900
Basic Combiner 12:6 with 6 antenna interfaces for 12 carriers
BCOM12PGV1 S30861-U2468-X P-GSM 900
BCOM12DV1 S30861-U2469-X GSM 1800
BCOM12PV1 S30861-U2470-X GSM 1900
LED Signal Meaning
POWER Green DC power supply is OK
Table 22 BCOM: LED Indications
-
A50016-G5100-A083-01-7620
67
HWMN:BTSE Modules Modules
Id:0900d805800f164a
2.12.1 BCOMPG/BCOMD/BCOMP
Figure 46 BCOMPG: Appearance
TX-Connector
Antenna Connector
RX-Connector
Powergreen LED
-
68 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
Figure 47 BCOMP: Appearance
TX-Connector
Antenna Connector
RX-Connector
Powergreen LED
Connector Connected to Module for Cell Configuration 2 / 2 / 2
Assigned Cell Number
ANT 0 Antenna 0 CELL / Sector 0
ANT 1 Antenna 1
ANT 2 Antenna 2 CELL / Sector 1
ANT 3 Antenna 3
Table 23 BCOM 6:6 Connector Assignment for Cell Configuration 2/2/2
-
A50016-G5100-A083-01-7620
69
HWMN:BTSE Modules Modules
Id:0900d805800f164a
ANT 4 Antenna 4 CELL / Sector 2
ANT 5 Antenna 5
TX0 CU(0)_TXOUT
BCOM-0_RX0 CU(0)_RX
BCOM-0_RX1 CU(1)_RXDIV CELL 0 (BTS:0)
TX1 CU(1)_TXOUT
BCOM-1 RX0 CU(1)_RX
BCOM-1_RX1 CU(0)_RXDIV
TX2 CU(2)_TXOUT
BCOM-2_RX0 CU(2)_RX
BCOM-2_RX1 CU(3)_RXDIV CELL 1 (BTS:1)
TX3 CU(3)_TXOUT
BCOM-3_RX0 CU(3)_RX
BCOM-3_RX1 CU(2)_RXDIV
TX4 CU(4)_TXOUT
BCOM-4_RX0 CU(4)_RX
BCOM-4_RX1 CU(5)_RXDIV CELL 2 (BTS:2)
TX5 CU(5)_TXOUT
BCOM-5_RX0 CU(5)_RX
BCOM-5_RX1 CU(4)_RXDIV
Connector Connected to Module for Cell Configuration 2 / 2 / 2
Assigned Cell Number
Table 23 BCOM 6:6 Connector Assignment for Cell Configuration 2/2/2
-
70 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
2.12.2 BCOM12PGV/BCOM12DV/BCOM12PV
Figure 48 BCOM12: Appearance
-
A50016-G5100-A083-01-7620
71
HWMN:BTSE Modules Modules
Id:0900d805800f164a
Figure 49 BCOM12: Interfaces
Connector Connected to Module for Cell Configuration 6 / 6 / 0 FlexCUs
Assigned Cell Number
ANT 0 Antenna 0 CELL / Sector 0
ANT 1 Antenna 1 CELL / Sector 0
ANT 2 Antenna 2 CELL / Sector 0
ANT 3 Antenna 3 CELL / Sector 1
ANT 4 Antenna 4 CELL / Sector 1
ANT 5 Antenna 5 CELL / Sector 1
BCOM-0_TX0 FCU(0)_TX 0 CELL / Sector 0
BCOM-0_TX1 FCU(2)_TX 1 CELL / Sector 0
Table 24 BCOM 12:6 Connector Assignment for Cell Configuration 6/6/0
-
72 A50016-G5100-A083-01-7620
HWMN:BTSE Modules
Id:0900d805800f164a
Modules
BCOM-0_RX0 FCU(0)_RX A/N0 CELL / Sector 0
BCOM-0_RX1 FCU(1)_RX B/D0 CELL / Sector 0
BCOM-0_RX2 FCU(2)_RX C/N1
BCOM-0_RX3 FCU(0)_RX D/D1
BCOM-1_TX0 FCU(1)_TX 0
BCOM-1_TX1 FCU(0)_TX 1
BCOM-1_RX0 FCU(1)_RX A/N0
BCOM-1_RX1 FCU(0)_RX C/N1
BCOM-1_RX2 FCU(2)_RX B/D0
BCOM-1_RX3 FCU(1)_RX D/D1
BCOM-2_TX0 FCU(2)_TX 0
BCOM-2_TX1 FCU(1)_TX 1
BCOM-2_RX0 FCU(2)_RX A/N0
BCOM-2_RX1 FCU(0)_RX B/D0
BCOM-2_RX2 FCU(1)_RX C/N1
BCOM-2_RX3 FCU(2)_RX D/D1
Connector Connected to Module for Cell Configuration 6 / 6 / 0 FlexCUs
Assigned Cell Number
Table 24 BCOM 12:6 Connector Assignment for Cell Configuration 6/6/0
-
A50016-G5100-A083-01-7620
73
HWMN:BTSE Modules Modules
Id:0900d805800f164a
BCOM-3_TX0 FCU(3)_TX 0 CELL / Sector 1
BCOM-3_TX1 FCU(5)_TX 1
BCOM-3_RX0 FCU(3)_RX A/N0
BCOM-3_RX1 FCU(4)_RX B/D0
BCOM-3_RX2 FCU(5)_RX C/N1
BCOM-3_RX3 FCU(3)_RX D/D1
BCOM-4_TX0 FCU(4)_TX 0
BCOM-4_TX1 FCU(3)_TX 1
BCOM-4_RX0 FCU(4)_RX A/N0
BCOM-4_RX1 FCU(3)_RX C/N1
BCOM-4_RX2 FCU(5)_RX B/D0
BCOM-4_RX3 FCU(4)_RX D/D1
BCOM-5_TX0 FCU(5)_TX 0
BCOM-5_TX1 FCU(4)_TX 1
BCOM-5_RX0 FCU(5)_RX A/N0
BCOM-5_RX1 FCU(3)_RX B/D0
BCOM-5_RX2 FCU(4)_RX C/N1
BCOM-5_RX3 FCU(5)_RX D/D1
Connector Connected to Module for Cell Configuration 6 / 6 / 0 FlexCUs
Assigned Cell Number
Table 24 BCOM 12:6 Connect