This photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations in this report will be based on data provided by a third party. The accuracy of this photometric report is dependent on the accuracy of the data provided. Enduser environment and application (including, but not limited to voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided. This report will be provided without warranty as to accuracy, completeness, reliability, or otherwise. In no event will Access Fixtures be responsible for any loss resulting from any use of this report. HUMA 12 36° Mounted at 10' Emits > 1fc 14' Across and 7' Out

Upload: others

Post on 14-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Societyof North America (IESNA). The calculations in this report will be based on data provided by a third party. Theaccuracy of this photometric report is dependent on the accuracy of the data provided. Enduser environmentand application (including, but not limited to voltage variation and dirt accumulation) can cause actualphotometric performance to differ from the performance calculated using the data provided. This report will beprovided without warranty as to accuracy, completeness, reliability, or otherwise. In no event will AccessFixtures be responsible for any loss resulting from any use of this report.

HUMA 12 36° Mounted at 10' Emits > 1fc 14' Across and 7' Out

Page 2: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Table of contents

HUMA 12 36° 10'Project Cover 1Table of contents 2Luminaire parts list 3Access Fixtures HUMA 36° AF53XYGWL182A 12W

Luminaire Data Sheet 4Exterior Scene 1

3D Rendering 5False Color Rendering 6Exterior Surfaces

Calculation SurfaceIsolines (E, Perpendicular) 7Greyscale (E, Perpendicular) 8Value Chart (E, Perpendicular) 9

Page 2

Page 3: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

HUMA 12 36° 10' / Luminaire parts list

1 Pieces Access Fixtures HUMA 36° AF53XYGWL182A 12WArticle No.: Luminous flux (Luminaire): 1080 lmLuminous flux (Lamps): 1080 lmLuminaire Wattage: 12.0 WLuminaire classification according to CIE: 100CIE flux code: 92 98 100 100 100Fitting: 1 x User defined (Correction Factor 1.000).

See our luminaire catalog for an image of the

luminaire.

Page 3

Page 4: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Access Fixtures HUMA 36° AF53XYGWL182A 12W / Luminaire Data Sheet

See our luminaire catalog for an image of the luminaire.

Luminous emittance 1:

Luminaire classification according to CIE: 100CIE flux code: 92 98 100 100 100

Due to missing symmetry properties, no UGR table can be displayed for this luminaire.

Page 4

Page 5: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Exterior Scene 1 / 3D Rendering

Page 5

Page 6: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Exterior Scene 1 / False Color Rendering

Page 6

Page 7: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Exterior Scene 1 / Calculation Surface / Isolines (E, Perpendicular)

Values in Footcandles, Scale 1 : 32Position of surface in external scene:Marked point:(17.750 ft, 32.500 ft, 0.000 ft)

Grid: 128 x 128 Points

Eav [fc] Emin [fc] Emax [fc] u0 Emin / Emax

4.07 0.28 21 0.069 0.014

Page 7

Page 8: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Exterior Scene 1 / Calculation Surface / Greyscale (E, Perpendicular)

Scale 1 : 32Position of surface in external scene:Marked point:(17.750 ft, 32.500 ft, 0.000 ft)

Grid: 128 x 128 Points

Eav [fc] Emin [fc] Emax [fc] u0 Emin / Emax

4.07 0.28 21 0.069 0.014

Page 8

Page 9: HUMA 12 36 Mounted at 10 · Thi s photometric report will be generated using methods recommended by the Illuminating Engineering Society of North America (IESNA). The calculations

HUMA 12 36° 10'12 / 22 / 2019

Access Fixtures

40 Jackson St. Worcester, MA

OperatorTelephone 800-468-9925

Faxe-Mail [email protected]

Exterior Scene 1 / Calculation Surface / Value Chart (E, Perpendicular)

Values in Footcandles, Scale 1 : 32Not all calculated values could be displayed.

Position of surface in external scene:Marked point:(17.750 ft, 32.500 ft, 0.000 ft)

Grid: 128 x 128 Points

Eav [fc] Emin [fc] Emax [fc] u0 Emin / Emax

4.07 0.28 21 0.069 0.014