Introduction to the OceanStor V3 Series Storage Systems
Overview
Where to get help
1
OceanStor 5300 V3&5500 V3&5600V3&5800 V3&6800 V3 Storage SystemV300R002 Quick Configuration Guide forBlock
Issue: 04
Release date: 2015-06-10
Before You Start
OceanStor V3 series storage systems are innovative mid-range and high-end offerings that are ready to meet your
current and future storage requirements. They are designed to provide medium- and large-scale enterprises with
improved storage performance, efficiency, data security, scalability, and manageability.
a
b
Feedbackc
This document helps you quickly configure the OceanStor 5300 V3&5500 V3&5600 V3&5800 V3&6800 V3
Storage System V300R002. For more information, see the OceanStor 5300 V3&5500 V3&5600 V3&5800
V3&6800 V3 Storage System V300R002 Basic Storage Service Guide for Block.
You can obtain this document from the documentation CD-ROM delivered with the product or from
http://enterprise.huawei.com. You can also register for a Huawei support account at this website to browse and
download valuable information and sign up for product updates.
Your feedback is important to us. If you have any comments about this document, please submit them to us on the
Huawei Enterprise website.
Copyright ©Huawei Technologies Co., Ltd. 2015.
All rights reserved.
5300 V3 5500 V3 5600 V3 5800 V3 6800 V3
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 2/282
1 Introduction
Basic application scenario1a
Initiator
Target
Maintenance terminal
Run the DeviceManager
FC
network
Identified by
port WWN
OceanStor storage system
Windows-based
application server
Linux-based
application server
UNIX-based
application server
Users can manage and maintain the storage
system from a maintenance terminal running
the DeviceManager program developed by
Huawei. The maintenance terminal connects
to the management network port of the
storage system.
1
2 3
4
1
The storage system provides storage space
for application servers.2
The storage system connects to application
servers over an Internet Small Computer
Systems Interface (iSCSI) network or Fibre
Channel (FC) network. Application servers
refer to the servers that run customer
services.
According to data transmission protocols, an
application server functions as the initiator
for data transmission, and a storage system
serves as the target for the information. The
initiator sends data read and write requeststo the target. The target receives, processes,
and responds to the requests.
3
Application servers run client programs. The
storage system can connect to application
servers running different operating systems
including Windows, Linux (SUSE, and Red
Hat), and UNIX (Solaris, AIX, and HP-UX).
4
iSCSI
network
Identified by
port IQN
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 3/283
Mapping views
LUN groups
Storage pool
Disk domain
Host groups
Disks
SSD SAS NL-SAS
High-performance tier Performance tier Capacity tier
Data area Data area Data area
Hot spare area Hot spare area Hot spare area
LUN group 1
Mapping view 2Mapping view 1
LUN group 2
Host group 1 Host group 2
1
2
3
4
5
6
Application servers7/dev/sdb1D:\
The storage system automatically identifiesall disks.
1
Disk domains are comprised of different
types of disks. Services of different disk
domains are isolated from each other.
2
Storage pools are created in disk domains
and comprised of RAID groups formed by
disks of different performance. Storage
pools provide logical storage space.
3
A LUN obtains storage space from the
storage pool. LUNs are the minimum logical
storage units that can be identified byapplication servers. A LUN group may
contain one or multiple LUNs.
4
Storage system1b
After mappings between host groups andLUN groups are established, related
application servers can access LUNs.
5
After initiators are added to hosts, one-to-
one logical mappings between hosts and
application servers are established. Then
application servers can use storage space
provided by the storage system. A host
group may contain one or multiple hosts.
6
The application server identifies LUNs as
logical disks. Then it can access the
detected logical disks in the same way it
would access local disks.
7
High-performance tier Performance tier Capacity tier
Windows
application
servers
Linux
application
servers
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 4/28
2 Data Preparation and Operation Instructions
4
Before operations, follow instructions in the following table to prepare data and enter actual values in the Value column.
Preparation Item Source Example Value
Maintenance terminal: Logging in to the DeviceManager
Management network port IP addressesNetwork
administrator
Default value:
192.168.128.101
A1
User name and password for logging in to the
DeviceManager
System
administrator
Default user name:
admin
Default password:
Admin@storage
A2
Maintenance terminal: Creating a disk domain
Disk domain name User-defined DiskDomain000 B1
Number of disks forming disk domains
Service
provider
Performance tier
(SAS): 30
Capacity tier
(NL-SAS) : 2
B2 Multi-choice
□ High-performance tier
(SSD):
□ Performance tier
(SAS):
□ Capacity tier
(NL-SAS):
Maintenance terminal: Creating a storage pool
Storage pool name User-defined StoragePool000 C1
Storage pool usageService
provider
Block Storage
Service
C2
Storage pool owning to Disk domainService
providerDiskDomain000
C3
Storage tier and capacity
Service
provider
Capacity tier
Capacity: 5 TB
C4 Multi-choice
□ High-performance tier
Capacity:
□ Performance tier
Capacity:□ Capacity tier
Capacity:
Data Preparation2a
High-performance tier uses SSDs.
Performance tier uses SAS disks.
Capacity tier uses NL-SAS disks.
This document uses example values to describe the configuration.Replace example values using actual values during actual configuration.The figure in the right shows the mappings of example values and actual values in the following table.
You are advised to change the default
password immediately after you have
logged in to the storage system for the first
time and periodically change your
password in the future. This reduces the
password leakage risks. For details about
how to modify the password, see
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage System
V300R002 Maintenance Guide.
A1
Example Actual value
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 5/285
Preparation Item Source Example Value
Maintenance terminal: Creating a LUN
LUN name User-defined LUN000 D1
CapacityService
provider100 GB
D2
QuantityService
provider1
D3
LUN owning to Storage poolService
providerStoragePool000
D4
Maintenance terminal: Creating a LUN group
LUN group name User-defined LUNGroup000 E1
LUNs from the LUN groupService
providerLUN000
E2
Networking mode of application servers and
storage arrays
Network
administratorFC network
E3□ iSCSI network
□ FC network
Application server: Configuring an iSCSI initiator (applicable to iSCSI connection)
Whether the application server installed the
UltraPath program
System
administratorNo
F1□ Yes
□ No
iSCSI initiator name User-defined initiator01 F2
IP address of the iSCSI host portNetwork
administrator10.10.10.11
F3
IP address of the application server network
port
Network
administrator10.10.10.12
F4
Maintenance terminal: Creating a host
Host name User-defined Host000 G1
Operating system of the application serverSystem
administratorWindows
G2
WWN or IQN
System
administrator21000024ff2d91a8
G3If the FC network is adopted, use the
WWN of the FC port of the application
server.
If the iSCSI network is adopted, use the
initiator name that is created during the
iSCSI initiator configuration.
A LUN group may contain one or multiple
LUNs.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 6/286
Preparation Item Source Example Value
Maintenance terminal: Creating a host group
Host group name User-defined HostGroup000 H1
Hosts from the Host groupService
provider Host000
H2
Maintenance terminal: Creating a port group (applicable to networks requiring specific ports forcommunication)
Whether you need to create a port groupService
providerYes
I1□ Yes
□ No
Port group name User-defined PortGroup000 I2
Ports from the Port groupService
provider
FC port
CTE0.A0.P0
I3
Maintenance terminal: Creating a mapping view
Mapping view name User-defined MappingView000 J1
LUN group from the Mapping viewService
providerLUNGroup000
J2
Host group from the Mapping viewService
providerHostGroup000
J3
Port group from the Mapping view
Service
providerPortGroup000
J4
Application server: Using storage space (applicable to Linux, and UNIX)
Mount directory User-defined /directory K1
If specific ports are required for
communication, select the created port
group.
Operation instructions2b
Before operations, learn about the meaning of icons involved in theconfiguration, as shown in the following table.
Icon Meaning
Double-click
Click
Right-click
Input or Set
Step
Substep
Example
2
1
A host group may contain one or multiplehosts.
A port group may contain one or multipleports.
1 2
Step1:
Substep1: Enter the user name and
password.
Substep2: Click Log In.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 7/28
Logging in to the DeviceManager
3 Allocating Storage Space
7
3a Creating a disk domain3b
Creating a storage pool3c
1
2
2
1
4
B1
3
For the actual disk numbers, see B2 in your data
preparation table. The figure above takes performance
tier and capacity tier creations as an example.
The security certificate prompt message varies withoperating systems and browser versions of maintenanceterminals. Ignore the message and continue accessingstorage devices.
A1
1. Enter the management IP address and theservice port ID of the storage device.
2. Click Enter .
A2
A2
2
1
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 8/288
Keep the default values for RAID Policy.
1
4
5
To create storage tiers, see the actual value
from C4 in your data preparation table. Thefigure above takes capacity tier creation as
an example.
2
C1
C2
Creating a LUN3d
3
2
D1
D4
If you need to create thin LUNs, enable the SmartThin
function. The value of Initial allocated capacity is theinitial capacity of the LUN, and that of Capacity is the
maximum capacity of the LUN.
Creating a LUN group3e
1
3
4
3 C3
D3
D2
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 9/289
E1
2
E2
Perform the next step based on your network type. See the
actual value from E3 in your data preparation table. iSCSI
network 4 Configuring an iSCSI Initiator
FC network 5 Setting Up a Connection
1
3
4
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 10/2810
2
4
3 F2
1
1
2
F33
4
Determine the operation sequence based on whether the UltraPath is installed. See the actual value from F1 in
your data preparation table.
If UltraPath is installed, perform the following steps: > > >
If UltraPath is not installed, perform the following steps: > > > > >
The name of an initiator must be unique. Otherwise, the connection between the storage systemand the application server fails.
4 (Optional) Configuring an iSCSI Initiator
Windows Server 20084a
3 4 1 2
3 1 2 4 5 6
7
8 7
8
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 11/2811
1
3
5
4
6
1
2
7
8
2
You have finished configuring an iSCSI initiator
5 Setting Up a Connection
F4
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 12/2812
Operation SUSE 11
Log in to the applicationserver
Enter root and its password
Verify the iSCSI initiator
installation
Run rpm -qa|grep open-iscsi
Start the iSCSI service Run /etc/init.d/open-iscsi start or service open-iscsi start
Set the iSCSI initiator
name
1. Run vi /etc/iscsi/initiatorname.iscsi2. Press i3.
Modify InitiatorName=ini t iator014. Press Esc5. Run :wq
Set the automatic
connection based on theiSCSI host port
1.
Run iscsiadm -m discovery -t st -p 10.10.10.11
2. Run iscsiadm -m node -l3. Run vi /etc/iscsi/iscsid.conf4. Press i5. Modify node.startup=automatic6. Press Esc7. Run :wq
Restart the iSCSI
service for the
configuration to take
effect
Run rcopen-iscsi start
Check whether the
settings are correct
Run iscsiadm -m node -p 10.10.10.11
You have finished configuring an iSCSI initiator 5 Setting Up a Connection
If the command output contains the iSCSI initiator version, the iSCSI initiator has been
installed.
If no command output is returned, the iSCSI initiator has not been installed.
For the actual value. See F2 in your data preparation table to modify the parameter in
your command.
For the actual value. See F3 in your data preparation table to modify the parameter in
your command.
The system displays the following information:
no records found!The previous information indicates that the login to the target failed. Verify that the network
connection is normal and previous parameter settings are correct.
SUSE 114b
The name of an initiator must be unique. Otherwise, the connection between the storage system and the application server
fails. Example values of command variables and example output are in italic. Replace the values in italic with the actual values.Before modifying the configuration file, back up it.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 13/2813
Red Hat 6.X4c
Operation Red Hat 6.X
Log in to the applicationserver
Enter root and its password
Verify the iSCSI initiator
installation
Run rpm -qa|grep iscsi
Start the iSCSI service Run /etc/init.d/iscsi start or service iscsi start
Set the iSCSI initiator
name
1. Run vi /etc/iscsi/initiatorname.iscsi2. Press i3.
Modify InitiatorName=ini t iator014. Press Esc5. Run :wq
Set the automaticconnection based on the
iSCSI host port
1.
Run iscsiadm -m discovery -t st -p 10.10.10.11
2. Run iscsiadm -m node -p 10.10.10.11 -l
3. Run vi /etc/iscsi/iscsid.conf4. Press i5. Modify node.startup=automatic6. Press Esc
7. Run :wq
Restart the iSCSI
service for the
configuration to takeeffect
Run /etc/init.d/iscsi restart
Check whether the
settings are correct
Run iscsiadm -m node
If no command output is displayed, the login to the target failed. Verify that the networkconnection is normal and previous parameter settings are correct.
If the command output contains the iSCSI initiator version, the iSCSI initiator has been
installed.
If no command output is returned, the iSCSI initiator has not been installed.
For the actual value. See F2 in your data preparation table to modify the parameter in
your command.
For the actual value. See F3 in your data preparation table to modify the parameter in
your command.
The name of an initiator must be unique. Otherwise, the connection between the storage system and the application server
fails.Example values of command variables and example output are in italic. Replace the values in italic with the actual values.
Before modifying the configuration file, back up it.
You have finished configuring an iSCSI initiator 5 Setting Up a Connection
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 14/2814
AIX 6.X4d
Operation AIX 6.X
Log in to the application
server
Enter root and its password
Verify the iSCSI initiator
installation
Run lslpp -l | grep -i iscsi
Set the iSCSI initiator
name
1. Run smit iscsi2. Highlight iSCSI Protocol Device by using direction keys and press Enter 3. Highlight Change / Show Characteristics of an iSCSI Protocol Device by using direction
keys and press Enter
4. Press Enter5. Highlight iSCSI Initiator Name by using direction keys and press Enter 6.
Change the value of iSCSI Initiator Name to ini t iator01 7. Press Enter8. Press Esc+09. Run lsattr -El iscsi0
Set the iSCSI host port
IP address
1. Run vi /etc/iscsi/targets2. Press i3.
Add 10.10.10.11 3260 iqn.2006-08.com.huawei:oceanstor:2100001882f31578::10.10.10.11
4. Press Esc
5. Run :wq
Check whether the
settings are correct
Run cfgmgr -v
The system displays the following information:devices.common.IBM.iscsi.rte
devices.iscsi.disk.rte
devices.iscsi_sw.rte
devices.iscsi.tape.rte
The iSCSI initiator has been installed.
If no command output is returned, the iSCSI initiator has not been installed.
For the actual value. See F2 in your data preparation table to modify the parameter in
your command.
For the actual value. See F3 in your data preparation table to modify the parameter in
your command.
Add the content in the format of Target IP address Port number Target name: Target IP
address.
If no command output is displayed, the login to the target failed. Verify that the network
connection is normal and previous parameter settings are correct.
The system displays the following information:iscsi0 Available iSCSI Protocol Device
iSCSI device iscsi0 is enabled, iscsi0 is used as an example.
The system displays the following information:initiator_name initiator01 iSCSI Initiator Name True
The iSCSI initiator name is configured successfully.
Log in to the storage system using the PuTTY software and run show iscsi target_nameThe system displays the following information:iSCSI Target Name : iqn.2006-
08.com.huawei:oceanstor:2100001882f31578:
iqn.2006-08.com.huawei:oceanstor:2100001882f31578: is the target name.
The name of an initiator must be unique. Otherwise, the connection between the storage system and the application server
fails.Example values of command variables and example output are in italic. Replace the values in italic with the actual values.Before modifying the configuration file, back up it.
You have finished configuring an iSCSI initiator 5 Setting Up a Connection
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 15/2815
Solaris 104e
Operation Solaris 10
Log in to the application
server
Enter root and its password
Verify the iSCSI initiatorinstallation
1. Run pkginfo | grep iscsi
2. Run svcs -a | grep iscsi
Set the iSCSI initiator
name
1. Run vi /etc/iscsi/initiatorname.iscsi2. Press i3.
Modify InitiatorName=ini t iator014. Press Esc
5. Run :wq
Set the iSCSI host port
IP address
1.
Run iscsiadm add discovery-address 10.10.10.11:3260
2. Run iscsiadm list discovery-address -v
Enable static search for
the iSCSI target device
Run iscsiadm modify discovery --static enable
Set up the iSCSI link
between the application
server and storage
system
Run devfsadm -i iscsi
Check whether the
settings are correct
Run iscsiadm list target
The system displays the following information:system SUNWiscsir Sun iSCSI Device Driver (root)
system SUNWiscsitgtr Sun iSCSI Target (root)system SUNWiscsitgtu Sun iSCSI Target (Usr)
system SUNWiscsiu Sun iSCSI Management Utilities (usr)
The iSCSI initiator has been installed.
The system displays the following information:
SUNiscsir: not foundThe iSCSI initiator has not been installed.
For the actual value. See F2 in your data preparation table to modify the parameter inyour command.
For the actual value. See F3 in your data preparation table to modify the parameter in
your command.
The system displays the following information:Target address :10.10.10.11:3260
The iSCSI host port IP address is configured successfully.
If no command output is displayed, the login to the target failed. Verify that the network
connection is normal and previous parameter settings are correct.
The system displays the following information:online 10:30:13 svc:/network/iscsi/initiator:default
online 10:30:13 svc:/system/iscsitgt:default
The iSCSI service has been enabled.
If the iSCSI service has not been enabled, run the svcadm enable iscsitgt command to
enable the iSCSI service.
The name of an initiator must be unique. Otherwise, the connection between the storage system and the application server
fails.Example values of command variables and example output are in italic. Replace the values in italic with the actual values.
Before modifying the configuration file, back up it.
You have finished configuring an iSCSI initiator 5 Setting Up a Connection
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 16/2816
HP-UX 11i V34f
Operation HP-UX 11i V3
Log in to the application
server
Enter root and its password
Verify the iSCSI initiatorinstallation
Run swlist iSCSI-00
Set the iSCSI initiatorname
1.
Run iscsiutil -i -N initiator01
2.
Run iscsiutil -i -A host1
Set the iSCSI host port
IP address
Run iscsiutil -a -I 10.10.10.11
Check whether the
iSCSI host port IPaddress is configured
successfully
Run iscsiutil -p -D
Log in to the target
device and create aspecial file
Run /usr/sbin/ioscan -NH 64000
If the command output contains the iSCSI initiator version, the iSCSI initiator has been
installed.
If no command output is returned, the iSCSI initiator has not been installed.
For the actual value. See F2 in your data preparation table to modify the parameter in
your command.
For the actual value. See F3 in your data preparation table to modify the parameter in your
command.
The system displays the following information:IP Address : 10.10.10.11
The iSCSI host port IP address is configured successfully.
The system displays the following information:H/W Path Class Description
==========================================================
64000/0xfa00/0x8f ctl XXXX
64000/0xfa00/0x90 disk XXXX
The login to the target device succeeded. XXXX indicates the device model or brand.
(Optional) Set the iSCSI initiator alias.
The name of an initiator must be unique. Otherwise, the connection between the storage system and the application server
fails.Example values of command variables and example output are in italic. Replace the values in italic with the actual values.
Before modifying the configuration file, back up it.
You have finished configuring an iSCSI initiator 5 Setting Up a Connection
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 17/28
5 Setting Up a Connection
17
Creating a host5a
2
1
3
G1
G2
1
3
4
1
2
In a Fibre Channel network environment, select FC
for initiator type. In an iSCSI network environment,
select iSCSI for initiator type.
NOTE
Creating a host group
2 G3
5b
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 18/2818
Optional: Creating a port group5c
Creating a mapping view5dDetermine whether to create a port group. See the
actual value from I1 in your data preparation table.Yes 5c Creating a port group
No 5d Creating a mapping view
1
2
H1
H2
4
2
1
3
2
1
I2
I3
3
1
3
4
J1
2
1
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 19/2819
1
2
If a port group has been created
If a port group has not been created
This picture assumes that the port group has not
been created.
J2
1
2
J31
2
21
J41
2
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 20/28
6 Using Storage Space
20
2
1
2
2
1
2
1
21
Windows Server 20086a
Perform this step when the logical disk partitionis larger than 2 TB.
1
3
1
3
2
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 21/2821
You have finished all configuration tasks. Now
you can use the storage space provided by the
storage system as a local disk.
After partitioning, the logical disk that has been
formatted is displayed as follows:
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 22/2822
SUSE 116b
Operation SUSE 11
Log in to the applicationserver
Enter root and its password
Verify the UltraPath
installation
Run rpm -qa|grep UltraPath
Scan for LUNs
iSCSI network and no UltraPath installedRun /etc/init.d/iscsi restartFC network and no UltraPath installed
1. Run lspci | grep -i fibre
2. --Emulex optical HBA
Run lsmod | awk '{print $1}' |grep lpfc--QLogic optical HBA
Run lsmod | awk '{print $1}' |grep qla
3. Run rmmod xxxx
4. Run modprobe xxxx
iSCSI or FC network and UltraPath installed
Run hot_add
View the informationabout all disks
Run fdisk -l
Partition the logical disk
1. Run fdisk /dev/sdc
2. Enter n and press Enter 3. Enter p and press Enter 4. Enter 1 and press Enter
5. Enter the value of default and press Enter
6. Enter the value of default and press Enter 7. Enter w and press Enter
Create a file system Run mkfs.ext3 /dev/sdc1
Create a file directory
Run mkdir /directory
Mount the partitioned
logical disk to the
directory
Run mount /dev/sdc1 /directory
Check whether thelogical disk has been
mounted
Run mount
If the command output contains the UltraPath version, the UltraPath has been installed.
The command output is the optical HBA driver name, for example, xxxx.
The optical HBA type is displayed after Fibre Channel:.
The system displays the following information:Disk /dev/sdc doesn’t contain a valid partition table
/dev/sdc is the newly mapped logical disk and does not contain any partitions, /dev /s dc isused as an example.
The command output is: First cylinder (…, default …)
The command output is: Last cylinder, +cylinders or +size{K,M,G} (…,default …)
For the actual value. See K1 in your data preparation table to modify the parameter in yourcommand.
The system displays the following information:/dev/sdc1 on /directory type ext3 (rw)
The logical disk is mounted successfully.
You have finished all configuration tasks. Now you can use the storage space provided by the storage system as a
local disk.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 23/2823
Red Hat 6.X6c
Operation Red Hat 6.X
Log in to the application
server
Enter root and its password
Verify the UltraPath
installation
Run rpm -qa|grep UltraPath
Scan for LUNs
iSCSI network and no UltraPath installed
Run /etc/init.d/iscsi restartFC network and no UltraPath installed
1. Run lspci | grep -i fibre
2. --Emulex optical HBA
Run lsmod | awk '{print $1}' |grep lpfc--QLogic optical HBARun lsmod | awk '{print $1}' |grep qla
3. Run rmmod xxxx
4. Run modprobe xxxx
iSCSI or FC network and UltraPath installed
Run hot_add
View the information
about all disks
Run fdisk -l
Partition the logical disk
1. Run fdisk /dev/sdc
2. Enter n and press Enter3. Enter p and press Enter 4. Enter 1 and press Enter
5. Enter the value of default and press Enter
6. Enter the value of default and press Enter 7. Enter w and press Enter
Create a file system Run mkfs.ext3 /dev/sdc1
Create a file directory
Run mkdir /directory
Mount the partitioned
logical disk to the
directory
Run mount /dev/sdc1 /directory
Check whether the
logical disk has been
mounted
Run mount
If the command output contains the UltraPath version, the UltraPath has been installed.
The command output is the optical HBA driver name, for example, xxxx.
The optical HBA type is displayed after Fibre Channel:.
The system displays the following information:Disk /dev/sdc doesn’t contain a valid partition table
/dev/sdc is the newly mapped logical disk and does not contain any partitions, /dev /s dc is
used as an example.
The command output is: First cylinder (…, default …)
The command output is: Last cylinder, +cylinders or +size{K,M,G} (…,default …)
For the actual value. See K1 in your data preparation table to modify the parameter in yourcommand.
The system displays the following information:/dev/sdc1 on /directory type ext3 (rw)
The logical disk is mounted successfully.
You have finished all configuration tasks. Now you can use the storage space provided by the storage system as a
local disk.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 24/2824
Operation AIX 6.X
Log in to the application
server
Enter root and its password
Scan for LUNs
Run cfgmgr
View the PVID of the
logical disk
Run lspv
Create a physical
volume group
1. Run mkvg -y testvg updisk3
2. Run lspv
Create a logical volume
Run mklv -y testlv -t jfs testvg 100
Create a file directory
Run mkdir /directory
Mount the partitioned
logical disk to the
directory
Run crfs -v jfs -d /dev/testlv -m /directory -A yes -a size=1024
Check whether the
logical disk has been
mounted
Run mount
The system displays the following information:hdisk0 000c6ce67e98ce56 rootvg active
updisk0 000c6ce66fc2cfc6 vg1
updisk1 000c6ce66fc2cfc6 vg1
updisk2 000c6ce67ed787c1 vg2
updisk3 None None
The PVID of the newly mapped logical disk is updisk3, updisk3 is used as an example.
The system displays the following information:updisk3 000c6ce67ee9fc27 testvg active
The physical volume is created successfully.
100 indicates that 100 physical extents are specified for logical volume testlv.
For the actual value. See K1 in your data preparation table to modify the parameter in your
command.
jfs indicates that a jfs file system is created on logical volume testlv. The file system
contains 1024 data blocks.
The system displays the following information:node mounted mounted over vfs date options
-------- --------------- --------------- ------ ------------ -------
/dev/testlv /directory jfs Mar 13 19:29 rw, log=/dev/loglv07
The logical disk is mounted successfully.
AIX 6.X6d
You have finished all configuration tasks. Now you can use the storage space provided by the storage system as a
local disk.
If you need to configure SAN boot when using UltraPath to connect an AIX host to a Huawei
storage device, see Installing AIX ODM for MPIO in the AIX ODM for MPIO User Guide to
install AIX ODM for MPIO before performing the following operations.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 25/2825
Operation Solaris 10
Log in to the applicationserver
Enter root and its password
Scan for LUNs
Run cfgadm -al
Partition the logical disk
1. Run format2. Enter the SN that is displayed after c1t1d0 and press Enter .3. Enter y and press Enter4. Run partition5. Run print
6. Run quit7. Run quit
Create a file system1. Run newfs /dev/dsk/c1t1d0s2
2. Enter y and press Enter
Create a file directory
Run mkdir /directory
Mount the partitioned
logical disk to the
directory
Run mount / dev/dsk /c1t1d0s2 /directory
Check whether the
logical disk has been
mounted
Run mount
For the actual value. See K1 in your data preparation table to modify the parameter in yourcommand.
The system displays the following information:Ap_Id Type Receptacle Occupant Conditionc1 scsi-bus connected configured unknown
c1::dsk/c1t1d0 disk connected configured unknown
c1t1d0 is the newly mapped logical disk, c1t1d0 is used as an example.
The system displays the following information:
Part Tag Flag Cylinders Size Blocks0 root wm 0 - 15 128.00MB (16/0/0) 262144
1 swap wu 16 - 31 128.00MB (16/0/0) 2621442 backup wu 0 - 6397 49.98GB 104824832
Normally, the part numbered 2 is the disk that is mapped to the host.
Solaris 106e
The system displays the following information:/directory /dev/dsk/c1t1d0s2read/write/setuid/devices/intr/largefiles/logging/xattr/oneerror=pan
ic/dev=…
The logical disk is mounted successfully.
You have finished all configuration tasks. Now you can use the storage space provided by the storage system as alocal disk.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 26/2826
Operation HP-UX 11i V3
Log in to the application
server
Enter root and its password
Scan for LUNs
Run ioscan -fnCdisk
View the name of the
disk that is mapped to
the storage system
Run ioscan -kfNnC disk
Create a physical
volume
Run pvcreate /dev/rdisk/disk402
Create a physical
volume group
1.
Run mkdir /dev/vgnn
2.
Run mknod /dev/vgnn/group c 64 0x110000
3. Run vgcreate /dev/vgnn /dev/disk/disk402
Create a logical volume Run lvcreate -l 5119 /dev/vgnn
Create a file system Run newfs /dev/vgnn/rlvol1
Create a file directory
Run mkdir /directory
Mount the partitionedlogical disk to the
directory
Run mount /dev/vgnn/lvol1 /directory
Check whether the
logical disk has been
mounted
Run mount
The system displays the following information:Class I H/W Path Driver S/W State H/W Type Description
====================================================================
disk 402 64000/0xfa00/0x92 esdisk CLAIMED DEVICE XXXX
/dev/disk/disk402 /dev/rdisk/disk402dev/rdisk/disk402 is the newly mapped logical disk, dev/rdisk/disk402 is used as an
example. XXXX indicates the product model or brand.
The system displays the following information:Increased the number of physical extents per physical volume to 5119.
Volume group "/dev/vgnn" has been successfully created.
Volume Group configuration for /dev/vgnn has been saved in
/etc/lvmconf/vgnn.conf
5119 indicates that the physical volume group has 5119 extents, 5119 is used as an
example. XXXX indicates the product model or brand.
For the actual value. See K1 in your data preparation table to modify the parameter in your
command.
The system displays the following information:/directory on /dev/vgnn/lvol1
ioerror=mwdisable,largefiles,delaylog,nodatainlog,dev=40110001 …
The logical disk is mounted successfully.
Create a directory for the physical volume. /dev/vgnn is used as an example.
Create a device file in the directory. For example, the device file is group . The minor
number of the device file is 0xNN0000. The value of NN must be unique. 0x110000 is
used as an example.
The system displays the following information:Class I H/W Path Driver S/W State H/W Type Description
====================================================================
disk 400 255/0/28.0.0.0 sdisk CLAIMED DEVICE XXXX
/dev/dsk/c76t0d0 /dev/rdsk/c76t0d0
The newly mapped LUNs are scanned successfully. XXXX indicates the product model or
brand.
HP-UX 11i V36f
You have finished all configuration tasks. Now you can use the storage space provided by the storage system as a
local disk.
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 27/28
7 How to Contact Huawei
27
Huawei customer service center Address: Huawei Industrial Base, Bantian, Longgang, Shenzhen 518129, People's Republic of China
Website: http://enterprise.huawei.com
Local Huawei technical support personnelObtain contact information for local Huawei offices at http://support.huawei.com/enterprise.
8 Next
If You Want to... Refer to... ISM Icon
Enable an appropriate storage tier
to be automatically selected for
each data block based on the data
activity level in order to improve
storage system performance and
lower the total cost of ownership
(TCO).
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage
System V300R002 SmartTier
Feature Guide
Prioritize critical services. OceanStor 5300 V3&5500 V3&5600V3&5800 V3&6800 V3 Storage
System V300R002 SmartQoS
Feature Guide
On-demand partitioning of storage
system cache resources ensures
the performance of critical
applications, improving the storage
system service quality.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage
System V300R002 SmartPartition
Feature Guide
Enable a quick intra-array data
backup.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 StorageSystem V300R002 Snapshot
Feature Guide
Back up or migrate data across
storage systems of different
vendors and in different areas.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage
System V300R002 LUN Copy
Feature Guide
Implement long-time data disaster
backup.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 StorageSystem V300R002 Remote
Replication Feature Guide
Create clones of a single piece of
data so that multiple applications
can concurrently read the same
piece of data.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage
System V300R002 Clone Feature
Guide
7/23/2019 Huawei storage quick configuration
http://slidepdf.com/reader/full/huawei-storage-quick-configuration 28/28
Migrates LUNs in or between
storage systems, adjusting and
allocating resources along with
business development.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage System
V300R002 SmartMigration Feature
Guide
Add or manage remote devices. OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage System
V300R002 SmartVirtualization Feature
Guide
Enable multiple tenants
to use the same application
program or computing
environment while separating their
data.
OceanStor 5300 V3&5500 V3&5600
V3&5800 V3&6800 V3 Storage System
V300R002 SmartMulti-Tenant Feature
Guide