how to connect prover signals
DESCRIPTION
Flow-X Flow Computer Provwe ConnectionTRANSCRIPT
HOW TO
Need support? Email: [email protected]
CONNECT PROVER SIGNALS
In this HowTo will be explained how prover signals should be connected. This
depends on the Flow-X type and the prover setup.
1. Flow-X/P Ball prover / Compact prover.
• Connect the flow pulse signals to the corresponding modules
• Connect all detector signals to all run modules.
Master meter proving based on pulses.
• Connect the flow pulse signals to the corresponding run module(s) and
“Master Meter” module.
• Connect a digital output of the “Master Meter” module to a digital
input (prove detector in) of itself and all run modules.
Master meter proving based on totals.
• No connections to be made (except for the pulse inputs in case of pulse
meters).
Figure 1: Proving connections to Flow-X/P
DATE 16/09/2013
VERSION 1.1
AUTHOR Louis Joosten
NUMBER OF PAGES 2
APPLIES TO Flow-X proving system
KEYWORDS
Prover signals
Flow-X
CONNECTING PROVER SIGNALS
Need support? Email: [email protected]
Page 2 of 2
2. Remote run / Separate prover module Ball prover / compact prover.
• Connect the flow pulse signals to the corresponding run modules.
• Connect the prover bus pulse output of the run modules to the pulse input of the prover module.
• Connect all detector signals to the prover module.
Master meter proving based on pulses.
• Connect the flow pulse signals to the corresponding run module(s) and “Master Meter” module.
• Connect the prover bus pulse output of the run modules to the ‘prove 2nd pulse input’ of the prover module.
• Connect a digital output of the “Master Meter” module to a digital input (prove detector in) of itself.
Master meter proving based on totals.
• No connections to be made (except from the pulse inputs in case of pulse meters).
Figure 2: Proving connections to remote run / separate prover module
CHANGE LOG Date Version By Description
12/09/2013 1.0 Peter van Deurzen Initial release
16/09/2013 1.1 Louis Joosten Complemented initial release