Home Booster Pump
H(m)
Q(/hr)
5
10
15
1 2
PB-088EA (50Hz)
Application
Technical Data
• Pressure boosting • Roof tank to tap water transfer
Approved fluids Clean water
Power Source
Max.flowrate
Max.head
Rated speed(rpm)
Fluid temperature
Ambient temperature
Max.working pressure 3bar
Up to +40
0to+60
2900
9.5m
2.4/hr
Flow switch “on” flowrate 0.12 /hr
220V, 50Hz, Single phase
Motor insulation class E
Voltage tolerance ±10%
Advantages
Unit Diagram
•Stable & Constant water pressure•Easy installation with Union•Low noise level : 39~41dB•Manual/Off/Auto optional operation•Motor built with Thermal Protector
for safety•Rust-proof by electric coating of casing
3
Home Booster Pump
Part List & Material
Sectional Drawing
* Recommended Spare Parts
Wiring Diagram
IdentificationPB - 088 E A
Pump BoosterPower(Output) : 08 x 10=80 W
Series Number50Hz
Automatic
No. Part Name Quantity Material
* 1 Motor Assembly 1 -
* 2 Mechanical Seal 1 Carbon & Ceramic
3 Hex Bolt 2 SM20C
* 4 Impeller 1 Noryl + G/F 20%
* 5 O-Ring 1 Rubber(NBR607)
6 Casing 1
7 Union & Nipple 2
8 Screw 2 SM20C
* 9 Flow Valve Asm 1 PP + G/F 30%
10 Screw 2 SM20C
* 11 Condenser 1 6 / 300VAC
12 Terminal Cover 1 PP + G/F 30%
13 Screw 1
14 Rocker Switch 1 Manual - Of f- Auto
(Rocker S/W)
(PCB)
MOTOR
Capacitor6300VAC
PowerSource
220V50Hz
R2R1
ReedS/W
Triac
Auto
Manual
Off
Earth
SM20C
*
*
Cast Iron (GG20)
Brass(CuZn40Pb2)
Home Booster Pump
H(m)
Q(/hr)
4
20
1 2
PB-200EA(50Hz)
Application
Technical Data
• Pressure boosting • Roof tank to tap water transfer• Pressure boosting hot water
Advantages• Stable & Constant water pressure• Easy installation with Union• Manual/Off/Auto optional operation• Motor built with Thermal Protector
for safety• Motor protection grade of IP44• Low motor temperature• Rust-proof by electric coating of casing
3
Identification
8
12
16
0
Approved fluids Clean water
Power Source
Max.flowrate
Max.head
Rated speed(rpm)
Fluid temperature
Ambient temperature
Max.working pressure 4bar
Up to +40
0to+60
2900
15m
3.2/hr
Flow switch “on” flowrate 0.1/hr
230V, 50Hz, Single phase
Motor insulation class
Degree of protection(Motor) IP44
B
Voltage tolerance ±10%
PB - 200 E A
Pump Booster
Power(Output) : 20 x 10=200 W
230V,50HzAutomatic
Series Number
Home Booster Pump
Part List & Material
Sectional Drawing
* Recommended Spare Parts
Wiring Diagram
Unit Diagram
(unit:mm)
④
⑤⑥
⑦
⑧
⑨
①②
③
⑩⑪
⑫
⑬
⑭
PowerSource
230V50Hz
Off
(Rocker S/W)
(PCB)
Motor
C9450VAC
R2R1
Triac
Auto
Manual
Earth
ReedS/W
Carbon & Ceramic
E-Coated Cast Iron
No. Part Name Quantity Material
* 1 Motor Assy 1 -
* 2 Mechanical Seal 1
3
* 4
Impeller 1 Noryl
* 5
O-Ring 1 Rubber
6 Casing1
7
Washer & Nut
1
STS304
8
* 9
Flow Valve Assy
1
Noryl / Magnet
10 Condenser
1
9 / 450VAC
1 ABS
*
Terminal Base
*
*
* 11
Fan PBT
12
1
1 ABS
*
Fan Cover
E-Coated Cast IronLiner 1
Switch Assy PBT + GF30%1
1 ABSTerminal Cover
* 13
14*
*
*
Home Booster Pump
Application• Pressure boosting • Roof tank to tap water• Pressure boosting hot water
Advantages
Identification
PB-201EA(50Hz)
H(m)
Q(/hr)
3
15
1 2 3
6
9
12
0 4
• Stable & Constant water pressure• Auto /Off/Manual optional operation• Motor built with Thermal Protector
for safety• Motor protection grade of IP44• Low motor temperature• Rust-proof by electric coating of casing
Technical DataApproved fluids Clean water
Power Source
Max.flowrate
Max.head
Rated speed(rpm)
Fluid temperature
Ambient temperature
Max.working pressure
Flow switch “on” flowrate
230V, 50Hz, Single phase
Motor insulation class
Degree of protection
Voltage tolerance
5bar
Up to+40
0to+80
2900
15m
3.9/hr
0.12/hr
IP44
B
±10%
Piping 25mm
PB - 201 E A
Pump Booster
Power(Output) : 20 x 10=200 WSeries Number
230V,50HzAutomatic
Home Booster PumpSectional Drawing
Wiring Diagram
Unit Diagram
Part List & Material
* Recommended Spare Parts
Carbon & Ceramic
E-Coated Cast Iron
No. Part Name Quantity Material
* 1 Motor Assy 1 -
* 2 Mechanical Seal 1
3
* 4
Impeller 1
* 5
O-Ring 1
6 Casing1
7
Washer & Nut
1
STS304
8
* 9
Flow Valve Assy
1
Noryl / Magnet
10 Condenser
1
-
1 ABS
*
Terminal Base
*
*
* 11
Fan PBT
12
1
1 ABS
*
Fan Cover
E-Coated Cast IronLiner 1
Switch Assy PBT+Reed Contact1
1 ABSTerminal Cover
* 13
14*
*
*
Rubber(NBR607)
Noryl + G/F 20%
1
27
3
456
8
8
10 1112
13
14
(unit:mm)
PowerSource
230V50Hz
Off
(Rocker S/W)
(PCB)
Motor
C
R2R1
Triac
Auto
Manual
Earth
ReedS/W
9450VAC
6
Home Booster Pump
H(m)
Q(/hr)Application
Technical Data
• Pressure boosting • Roof tank to tap water• Pressure boosting hot water
Approved fluids Clean water
Power Source
Max.flowrate
Max.head
Rated speed(rpm)
Fluid temperature
Ambient temperature
Max.working pressure 3bar
Up to+40
0to+60
2900
19m
4.3/hr
Flow switch “Off” flowrate 0.3 /hr
230V, 50Hz, Single phase
Motor insulation class
Degree of protection(Motor) IP44
B
Voltage tolerance ±10%
Advantages• Stable & Constant water pressure
due to Flow switch inside of casing• Easy installation with Flange• Motor built with Thermal Protector
for safety• Low motor temperature by Cooling Fan• Rust-proof by electric coating of casing
Identification
PB-250SEA
P B – 2 5 0 S E A
Output : 250WSmall Press. Tank
0
3
6
9
12
15
18
21
24
1.0 2.0 3.0 4.0
Pressure switch “On” Press. 0.8bar
-
No. Part Name Quantity Material
1
Check Valve Assy 1
2
Capacitor 1
3
* 4
Mechanical Seal 1 Carbon & Ceramic
* 5
Impeller 1
6
Motor Assy
7
1
8
* 9
Casing
1
E-Coated Cast Iron
10
Switch Assy
1
PBT/Reed Contact
*
*
1 ABS
*
Terminal Cover
Fan PBT1
1 ABSFan Cover
*
*
*
Drain screw 1 -
Noryl & Magnet
Terminal Base 1 ABS
-PCB Assy -
-Pressure Tank -
-
11
12
13
14
Home Booster Pump
Part List & Material
Sectional Drawing
Wiring Diagram
* Recommended Spare Parts
Unit Diagram
Noryl + G/F 20%
(unit:mm)
5
*
3
4
8
9 10
6
7
14
12
Home Booster Pump
PB-400EA (50Hz)
Application
Technical Data
• Pressure boosting • Roof tank to tap water transfer
Approved fluids Clean water
Power Source
Max.flowrate
Max.head
Rated speed(rpm)
Fluid temperature
Ambient temperature
Max.working pressure 6bar
Up to +40
0to+80
2900
19m
4.8/hr
Flow switch “on” flowrate 0.1/hr
220V, 50Hz, Single phase
Motor insulation class
Degree of protection(Motor) IPX4
B
Voltage tolerance ±10%
Advantages• Stable & Constant water pressure• Manual/Off/Auto optional operation• Motor built with Thermal Protector
for safety• Motor protection grade of IPx4• Low motor temperature• Rust-proof by electric coating of casing
Unit Diagram(unit:mm)
H(m)
Q(/hr)
5
10
15
1 2 3
20
4 5
PB-400EA
PB- 200EA
PB-088EA
Home Booster Pump
Part List & Material
Sectional Drawing
Wiring Diagram
IdentificationCarbon & Ceramic
E-Coated Cast Iron
No. Part Name Quantity Material
* 1
Motor Frame Assy 1
* 2
Mechanical Seal 1
3
* 4
Impeller 1 Noryl
* 5
End Bracket(A) 1 ALDC
6
Casing
7
1
8
* 9
Flow Valve Assy
1
Noryl / Magnet
10
Condenser
1
18 / 400VAC
*
*
*
PowerSource
220V50Hz
Off
(Rocker S/W)
(PCB)
Motor
C18400VAC
R2R1
Triac
Auto
Manual
Earth
ReedS/W
* Recommended Spare Parts
PB - 400 E A
Pump Booster
Power(Output) : 40 x 10=400 WSeries Number
50HzAutomatic
*
1 ABS
*
Fan & Fan Cover
Switch Assy PBT / Reed Contact11 ABSTerminal Box
*
*
*
*
1 23
48
910
7
65
Liner 1 E-Coated Cast Iron
ALDC / S60
End Bracket(B) 1 ALDC
NBRO-Ring -
NBRGasket -
Home Booster Pump
Application
Technical Data
• Pressure boosting• Roof tank to tap water• Pressure boosting hot water
Approved fluids Clean water
Power Source
Max.flowrate
Max.head
Rated speed(rpm)
Fluid temperature
Ambient temperature
Max.working pressure 5bar
Up to+40
0to+60
2900
22m
4.2/hr
Flow switch “Off” flowrate 0.3 /hr
220V, 50Hz, Single phase
Motor insulation class
Degree of protection(Motor) IP44
B
Voltage tolerance ±10%
Advantages• Stable & Constant water pressure
by applying Flow Switch• Easy installation with Flange• Motor built with Thermal Protector
for safety• Low motor temperature by Cooling Fan• Rust-proof by electric coating of casing
Identification
PB-401SEA
P B – 401 S E A
Output : 400W
Small Press. Tank
Pressure switch “On” Press. 1.1barAutomatic
H(m)
Q(/hr)
5
10
15
1 2 3
20
4 5
-
No. Part Name Quantity Material
1
1
2
PCB Assy 1
3
* 4
Mechanical Seal 1 Carbon & Ceramic
* 5
1
6
Motor Assy
7
1
8
* 9
Casing
1
E-Coated Cast Iron
10
Capacitor
1
-
*
*
1
ABS
*
Terminal Cover
Fan PBT1
1 ABSFan Cover
*
*
Impeller 1
Terminal Base 1 ABS
Pump Cover
-
11
12
Home Booster Pump
Part List & Material
Sectional Drawing
Wiring Diagram
* Recommended Spare Parts
Optional parts
Unit Diagram(unit:mm)
*
⑧ Terminal Cover
⑨Terminal Base
⑥PressureTank
⑤PressureSwitch
② M/Seal③ Impeller
④Casing ⑩Check Valve Assy ④Motor Supporter
⑦FanCover
①Motor
⑥Fan
⑪Capacitor
Noryl + G/F 20%
Pressure switch On : 1.1kgf/
⑫PCB Assy
Check Valve Assy 1 C3771BD
P.P-
HD P.E-
18400VAC
TRIAC
390Ω330Ω
Reed Switch
M
S
C
PCB
Motor
Power source1Ø,220V/50Hz
Pressure Switch
Pump Base
13
14
*
*