“FASTER AND SMALLER” SYMPOSIUM HIGHLIGHTS FROM THE Sponsored by Alcon Supplement to November/December 2014 A Video Presentation of the New Surgical Techniques Symposium in Tokyo

Upload: others

Post on 26-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

“FASTER AND SMALLER”SYMPOSIUM

HIGHLIGHTS FROM THE

Sponsored by Alcon

Supplement to

November/December 2014

A Video Presentation of the New Surgical Techniques Symposium in Tokyo

Page 2: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

2 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014

These articles are based on presentations given during a lunch symposium titled “Faster and Smaller: A Video Presentation of New Surgical Techniques.”

The symposium was held during the World Ophthalmology Congress of the International Council of Ophthalmology, April 2-6, 2014, Tokyo, Japan.

CONTENTS

Advanced Vitreotretinal Surgery With Faster Cut Rates and Smaller Gauges . . . . . . . . . . . . . . . . . . . . . . 3By Pravin U. Dugel, MD

Advancing the Treatment of Complex Cases With Small-Gauge Technology . . . . . . . . . . . . 5By Maria H. Berrocal, MD

Microincisional Surgery With 27-Gauge Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . 7By Yusuke Oshima, MD, PhD

Advantages of the Ultravit High Speed Cutter . . . . . . . . . . . . . . . . . . . 9By Kazuaki Kadonosono, MD

Question & Answer Session . . . . . . . . .10

“FASTER AND SMALLER” SYMPOSIUM

HIGHLIGHTS FROM THE

Maria H. Berrocal, MD, is assistant professor of medicine at the University of Puerto Rico School of Medicine in San Juan, Puerto Rico, and direc-tor of Berrocal and Associates. Dr. Berrocal is a paid consultant to Alcon. She may be reached

at [email protected].

Pravin U. Dugel, MD, is managing partner of Retinal Consultants of Arizona, Phoenix, Arizona; clinical professor of ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles; and founding member of

the Spectra Eye Institute in Sun City, Arizona. He is a paid con-sultant to Alcon and a consultant to Novartis. Dr. Dugel may be reached at [email protected].

Kazuaki Kadonosono, MD, is professor and chairman of the department of ophthalmol-ogy with Yokohama City University Medical Center in Yokohama, Japan. Dr. Kadonosono is a paid consultant to Alcon.

Dr. Kadonosono may be reached at +81-45-253-8490; [email protected].

Yusuke Oshima, MD, PhD, is the founder and director of Oshima Eye Clinic, a vitreoretinal and cataract surgery center in Takatsuki; a consultant and visiting surgeon at the Nishikasai Inoue Eye Hospital; a visiting lecturer of ophthalmogy at

Kyoto Prefectural University of Medicine, Kyoto, all in Japan; and an honorary director of the vitreoretinal division at the Tianjin Eye Hospital and visiting professor of ophthalmology at the Nankai University in Tianjin, China. Dr. Oshima is a paid consultant to Alcon and a consultant for Synergetics. Dr. Oshima may be reached at [email protected].

CONTRIBUTORS

To view the digital version of this supplement, visit EyeTube.net or Retina Today.com.

Page 3: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

NOVEMBER/DECEMBER 2014 SUPPLEMENT TO RETINA TODAY 3

When I started as a retinal surgeon, we did not have many choices regarding instru-mentation and speed. I was given a cutter that performed at 400 cuts per minute

(cpm) and was told, “This is what you use.” As retinal sur-geons, the cut rate and gauge are important parameters to consider. I discuss my thought process regarding those parameters herein.

ULTRA-HIGHSPEED CUT RATE I choose to remove vitreous gel with the fastest cut rate

available, because research shows that a faster cut rate creates the least amount of traction when removing vitre-ous.1,2 The vitreous traction can be calculated with this formula:

length (of pull of the collagen fibrils) = flow rate/lumen area/cut rate.

If the length of pull of the collagen fibrils is shortened, then traction is lowered with a higher cut rate. Therefore, reducing vitreous traction lowers the risk of causing a tear. Faster cut rates translate into a shorter length of pull of the vitreous, and thus less traction, regardless of the dis-tance from the port of the cutter.

In the era of spring-based vitreous cutters, ultra high-speed cut rates were not always achievable, and when they were, there was little control over flow; when flow is reduced, the surgical efficiency declines. With modern dual-pneumatic cutters, however, duty cycle control is maintained. I have more surgical confidence with dual-pneumatic cutters because I know flow rate will not decrease intraoperatively with an ultra-highspeed cut rate.

CHOOSING AN APPROPRIATE FLOW RATEHaving a very high flow may not always be desirable;

it may increase the risk of retinal tears due to amplified

vitreoretinal traction (Figure 1). Flow rate is an important but misunderstood surgical parameter. Many surgeons believe the higher the flow, the better, but that is not necessarily the case. Instead, surgeons should think in terms of achieving appropriate flow. That means when one is working with a detached retina, the flow should be low enough to avoid or prevent inadvertent incarcera-tion. When one is working away from the retina, perhaps performing a core vitrectomy, a higher flow rate would be appropriate. Surgeons sometimes confuse flow with acceleration (the rate of rise of flow). It is acceleration, not flow, that helps with the deformation and removal of pathologic tissue, such as retained lens material and thick fibrous tissue.

THE BENEFITS OF SMALLER INSTRUMENTATIONAnother key factor in advancing modern retina surgery

is the advent of small-gauge instrumentation. I was involved in a study that demonstrated that large-

gauge cutters require more flow for tissue retraction. My colleagues and I found that when the distance between the cutter and tissue was kept constant, generating tissue

BY PRAVIN U. DUGEL, MD

Advanced Vitreoretinal Surgery With Faster Cut Rates and Smaller Gauges

Figure 1. Higher flow rates increase the risk of retinal tears due

to increased traction.

HIGHLIGHTS FROM THE

Page 4: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014

attraction required almost twice as much flow with a large-gauge cutter compared with a small one. This principle has been reported with 20-gauge, 23-gauge, and 25+ instrumentation, and it also applies to 27+ instruments (Figure 2). I have coined the term sphere of influence to describe this important effect (Figure 3). It can crudely be thought of as “collateral damage.” Sphere of influence, in effect, describes the region around the port influenced by fluid dynamics. Our study found that the sphere of influence on surrounding tissue was great-est with large-gauge vitrectomy probes.3 The smaller the sphere of influence, the more precise the surgery will be with the least amount of “collateral” damage.

Here’s another way to understand this concept in terms of gauge selection. We want to precisely remove fibrous tissue during an operation, but we do not want retinal incarceration. If the sphere of influence is large, we will be “imprecise” and risk retinal incarceration (collateral dam-age). With small-gauge surgery, we can precisely remove pathologic tissue without causing incarceration (minimal risk of collateral damage).

I choose to operate with the smallest possible gauge. I currently use the Ultravit High Speed 25+ Probe (Alcon), and when the 27+ becomes available, I will use it. The Ultravit High Speed 25+ Probe allows increased access to tissue planes, but with a small sphere of influence. The combination of the highest cut rate available with the smallest gauge available allows me greater precision.1 In other words, smaller gauge instruments designed effi-ciently can help achieve better performance than large-gauge probes while offering improved fluidic precision and safety.2

CASE EXAMPLEThe value of 27+ instrumentation can be demonstrated with a surgery I performed on a patient with a rhegmatogenous

retinal detachment. Because the cutter was very small, I was able to maneuver between tissue planes without a lot of manipulation. The cutter’s small sphere of influence allowed me to remove fibrous tissue very precisely without fear of incarceration.

A common misperception with smaller probes is that surgery will take longer. In this case, I was able to execute the entire case with 1 instrument and remove the tissue precisely, because the sphere of influence was small. I was also able to finish the entire surgery without taking the cutter out of the eye. At the end of the day, it is not about speed, but about efficiency. There is a great deal of effi-ciency in being able to remove pathologic tissue precisely without multiple exchanges of instruments.

CONCLUSIONThe stiffness of 27+ instruments has not been a concern

for me. In fact, these instruments are designed with a strut to enhance the stiffness. Overall, the advantages provided by small-gauge instruments in terms of precision and con-trol outweigh flexibility concerns, in my opinion.

The 27+ technology is designed to offer surgeons the following: (1) exceptional access to small tissue planes; (2) efficiency, with use of the probe as a multifunctional tool with appropriate flow; and (3) precision, as the reduced sphere of influence will allow enhanced control. I have had the opportunity to use all of the gauges available, including 27+. When the 27+ instrument becomes available, I am convinced that I will use it for all of my cases. n

1. Abulon DJ , Buboltz DC. Porcine vitreous flow behavior during high-speed vitrectomy up to 7500 cuts per minute. Poster A224. Presented at: ARVO; May 6-9, 2012; Ft. Lauderdale, FL. 2. Rizzo S, Genovesi-Ebert F. Comparative study of the standard 25-gauge vitrectomy system vs. the new ultra-highspeed vitrectomy system. Retina Today. September insert. 2010. 3. Dugel PU, Zho J, Abulon DJ, Buboltz DC. Tissue attraction associated with 20-gauge, 23-gauge, and enhanced 25-gauge dual-pneumatic vitrectomy probes. Retina. 2012;32:1761-1766.

Figure 3. The sphere of influence describes the region around

the port influenced by fluid dynamics.

Figure 2. Attraction distance for various probe gauges.

Page 5: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

NOVEMBER/DECEMBER 2014 SUPPLEMENT TO RETINA TODAY 5

Modern surgical equipment allows retina surgeons to take new approaches to com-plex surgery. Some believe that small-gauge vitrectomy is ideal for simpler cases, such

as biopsies, endophthalmitis, and vitreous floaters, but not for complicated cases. However, that notion misses the point.

Smaller-gauge surgery with 27-gauge instrumentation has several advantages (Figure 1). The smaller opening can aspirate on the surface of the retina for delicate peeling. The high cutting rates possible with 27-gauge instrumentation allow the surgeon to shave tissue from the surface of the retina with less need for bimanual dis-section. Another advantage of 27-gauge instrumentation is that the smaller probe can fit into very tight spaces between membranes, allowing for more control when peeling tissue.

MANAGING COMPLEX CASES WITH SMALLER PROBES

The Constellation Vision System (Alcon) allows the vitreoretinal surgeon to perform small-gauge maneu-vers that were not possible in the past. It is capable of high-speed cutting rates of 7500 cuts per minute (cpm), which means the surgeon can shave the retina with mini-mal movement of the tissue underneath. The advanced fluidics of the Constellation offer high surgical efficiency and allow the surgeon to essentially erase the vitreous and shave abnormal tissue with minimal turbulence.

The 27+ probes available with this system allow for unique approaches to complex cases. For instance, both 25+ and 27+ instruments can be inserted between tis-sue planes to dissect and shave tissue from the surface of the retina, which may be particularly advantageous in diabetic cases and cases of rhegmatogenous reti-nal detachment. Suction can be used to lift the tissue slightly, and then the cutter can remove it. Because the

cutter is designed with the opening very close to the tip, the surgeon can easily remove large sheets of tissue in an efficient manner, minimizing traction on the detached retina and possible iatrogenic breaks.1

Some of the new techniques that can be performed with 25+ and 27+ vitrectors with the Constellation Vision System include the delamination of fibrovascular tissue, back cutting, back shaving, and erasing mem-branes from the surface of the retina with minimal movement of the underlying retina because of decreased traction and decreased sphere of influence.1-3

EXPERIENCE WITH 27-GAUGE INSTRUMENTS I first used 27+ instruments during a retinal detachment

in a pseudophakic patient (Figure 2). I removed some of the vitreous behind the lens. With suction, I used the 27+ instrument as though it were forceps to remove part of the posterior hyaloid in an elegant, controlled manner. Afterward, I was able to lift part of the vitreous from the surface and maneuver the instrument under the tissue to

BY MARIA H. BERROCAL, MD

Advancing the Treatment of Complex Cases With Small-Gauge Technology

Figure 1. Advantages of 27- versus 25-gauge instru-mentation.

Page 6: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

6 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014

shave it. In the past, I would have used viscodissection and created space between the abnormal tissue and retina in these types of cases; however, I think it is possible to perform the entire surgery with the probe. With 27-gauge, however, the probe is small and can perform as a blunt dissector, so fibrovascular tissue removal can be performed expediently.

Another technique that is possible with the 27-gauge probe became evident when I operated on a phakic eye with an epiretinal membrane. It surprised me to see how quickly I could remove the vitreous using maximum aspiration and cutting speed. I injected triamcinolone to visualize the vitreous and the posterior hyaloid, and then I lifted the epiretinal membrane and peeled it with suc-tion, all without the need of forceps. It was very easy to lift both the posterior hyaloid and epiretinal membrane with significant control. Once the epiretinal membrane was removed, dye was injected to stain the internal limit-ing membrane, and the vitrectomy probe was utilized to peel the internal limiting membrane with minimal trauma to the underlying retina.

SYSTEM FEATURESThe Constellation Vision System has been engineered

to allow for high cutting rates with maximum flow through the system. The 27+ vitrector can be used at 7500 cpm with practically the same flow as the 25+.4,5

The smaller probe can fit under spaces between mem-branes, and the smaller opening allows for more control when peeling tissue. This smaller size also allows us to perform surgery through smaller incisions.

In the past, the 20-gauge probe was the only probe available; now surgeons have access to 20-, 23-, 25-, and 27-gauge probes. There is a full range of associated instrumentation, such as chandeliers with the 25-gauge, 27-gauge needles, and forceps and scissors. This arma-mentarium of equipment will allow retina surgeons to perform surgery with great precision and accuracy.

The dual-pneumatic 27+ vitrectomy probe allows the opening to be open most of the time. With spring-action cutters or single-pneumatic probes, the opening is closed

50% of the time. The opening on the 27+ vitrectomy probe is actually programmable so that surgeons can adjust the time the probe is open depending on what structures are being removed.

CONCLUSIONSmaller vitrectomy cutters have several significant advan-

tages, and these become more evident in complex cases, such as in diabetic retinal detachments. In the future, it is very possible that we will perform very delicate and precise surgical maneuvers with the 27-gauge probe. n

1. Rizzo S, Genovesi-Ebert F. Comparative study of the standard 25-gauge vitrectomy system vs. the new ultra-highspeed vitrectomy system. Retina Today. September insert. 2010.2. Teixeira A, Chong L, Matsuoka N, et al. An experimental protocol of the model to quantify traction applied to the retinal by vitreous cutters. IOVS. 2010;51(8):4181-4186. 3. Hubschman JP, Gupta A, Bourla DE, et al. 20-, 23-, and 25-gauge vitreous cutters performance and characteristics evaluation. Retina. 2008;28(2):249-257.4. Abulon DJ, Buboltz DC. Porcine vitreous flow behavior during high-speed vitrectomy up to 7500 cuts per minute. Poster A224. Presented at: ARVO; May 6-9, 2012; Ft. Lauderdale, FL. 5. Ray A, Abulon DJ, and Dimalanta RC. Intraocular pressure and BSS flow rates at high vitrectomy probe cut rates. Poster A225. Presented at: ARVO; May 6-9, 2012; Ft. Lauderdale, FL.

Figure 2. With small-gauge instruments, it may be possible to

both lift tissue and shave underneath with a single instrument.

Page 7: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

NOVEMBER/DECEMBER 2014 SUPPLEMENT TO RETINA TODAY 7

A recent study in Japan showed that more reti-nal surgeons are using 25-gauge systems for microincisional vitrectomies. In fact, in March 2013, 65% of Japanese surgeons were using

25-gauge vitrectomy compared with 30% who were using 23-gauge, while only 5% were using 20-gauge.1 The numbers show that surgeons are increasingly interested in small-gauge surgery.

27-GAUGE SYSTEMSI have been involved in the development of the Ultravit

27+ system (Alcon). This latest iteration of surgical tech-nology would not have been possible without previous developments in vitreoretinal surgery (Figure 1). Now, the era of 27-gauge instrumentation is upon us, and there is a full line of small-gauge instruments available (Figure 2). In my hands, the 27+ vitrectomy instru-mentation is very efficient, and I use it in most of my surgical cases.

My colleagues and I conducted a study at our facility that included 31 eyes undergoing vitrectomy with 27+ instru-ments. No eyes required a transition to larger-gauge instruments during surgery, and all sclerotomies healed at the end of surgery without hypotony. Anatomic success was achieved in all surgeries, and 65% of eyes had more than a 3-line gain in postoperative visual acuity. We con-cluded that the 27+ system was effec-tive and reduced concerns about com-plications associated with wound sealing related to selected cases (Figure 3).2

The use of 27+ instruments is ideal for spontaneous wound closure. Our research found that compared with a 25+ cutter, the duty cycle of the 27+

cutter is 61% at 1000 cuts per minute (cpm) and 38% at 1500 cpm; it was equal to or better than those of the 25-gauge cutter (62% and 28%, respectively).2

VERSATILITYThe Ultravit 27+ system is useful for many situations,

including many challenging cases. The Alcon Ultravit High Speed Probe is a dual-pneumatic drive probe that provides efficient cutting up to 7500 cpm. The probe is designed to reduce pulsatile traction without fluidic compromise. This probe does not alter flow, and it main-tains efficient vitreous aspiration compared with a 5000-cpm probe.3,4

The 27+ system provides benefits for surgeries, includ-ing those involving diabetic eyes. Previously, surgeons had to use more complex instruments to complete

BY YUSUKE OSHIMA, MD, PhD

Microincisional Surgery With 27-Gauge Instruments

Figure 1. The road map of the 27-G project. The advent of 27-gauge surgery

necessitated the previous development of advanced light sources and surgical

technology.

Page 8: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

8 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014

surgery in these eyes, incuding horizontal scissors with special picks to remove the membrane. With a small port cutter, the Ultravit 27+ system becomes more functional. In our center, we use a small cutter to gently lift the membrane, separate it from the retina, and finally use the cutter-like scissors to remove the membrane. I believe the 27+ Ultravit has a wider application for much more challenging cases.

The 27+ Ultravit system can be used in a variety of surgeries, includ-ing macular surgery, nonclearing vitreous hemorrhage or opacity, diabetic retinopathy, primary retinal detachment, subretinal hemor-rhage, and possibly with retained lens fragments and intraocular lens dislocations.

CONCLUSIONThe newly developed 27+

Ultravit system has greatly improved the efficiency and func-tionality of vitrectomy surgery. The further development of 27+ instru-ments, such as chandelier fiber optics, is critical for further wide-spread use of this system. n

1. Data on file. Alcon Laboratories, Inc., Fort Worth, TX. 2. Oshima Y, Wakabayashi T, Tatsuhiko S, et al. A 27-gauge instrument system for transconjunctival vitrectomy surgery. Ophthalmology. 2010;117:93-102.3. Abulon D, Buboltz D. Porcine vitreous flow behavior during high speed vitrectomy up to 7500 cpm. Poster presented at: ARVO; May 6-9, 2012; Ft. Lauderdale, FL.4. Novack R, Zhou J, Abulon D, Buboltz D. Relationship of duty cycle vs. cut rates for two commercially available vitrectomy systems. Poster presented at: Ameri-can Society of Retina Specialists; Aug. 28-Sept. 2, 2010; Vancouver, BC, Canada.

Figure 2. The full line of 27-gauge instruments offered by Alcon.

Figure 3. A study at our center demonstrated the feasibility of using 27-gauge instru-

mentation in a variety of surgeries.

Page 9: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

NOVEMBER/DECEMBER 2014 SUPPLEMENT TO RETINA TODAY 9

As vitrectomy surgery becomes more common-place, retinal surgeons need the most effective technology at their disposal. This enhanced activity is likely due to greater availability of

improved technology and instrumentation, and a better understanding of ocular pathology.

HIGH-RATE CUTTINGNewer surgical instrumentation affords surgeons a higher

cutting rate, which may lower the risk of peripheral retinal breaks and hemorrhages. After using both 25+ and 27+ vitrectomy cutters with a cut rate of 7500 cuts per minute (cpm) with the Constellation Vision System (Alcon), it is my opinion that the 27+ instrumentation allows me to maximize the system’s cutting-edge capabilities.

Because a higher cutting rate contributes to less turbulence in the vitreous, it allows for a more stable retina during vitreoretinal surgery and enhanced control (Figure 1). It is commonly believed that a higher cutting rate equates to less aspiration flow during vitrectomy. In actuality, the aspiration flow of the vitreous increases with a higher cutting rate.1 This is because the viscosity of the vitreous decreases when it is removed with a high cutting rate.

There has been concern about the decreased duty cycle of vitrectomy probes using a higher cutting rate. However, the Constellation has an adjustable duty cycle,

so surgeons can choose between bias open, bias closed, or neutral, expanding the capabilities in the core and shave modes (Figure 2).

I still use a 25+ vitrectomy probe with 7500 cpm in a few circumstances; for instance, when it is necessary to bimanually remove a membrane in eyes with prolifera-tive diabetic retinopathy or the peripheral vitreous in eyes with retinal detachment; to remove the posterior capsular membrane in eyes with an intraocular lens; and to trim the internal limiting membrane during the use of an inverted flap technique in eyes with a large macular hole.

CONCLUSIONIn the near future, I foresee that high speed probes

will be in the OR of every vitreoretinal surgeon. n

1. Abulon D, Buboltz D. Porcine vitreous flow behavior during high speed vitrectomy up to 7500 cpm. Poster presented at the Annual ARVO Meeting, May 6-9, 2012; Fort Lauderdale, FL.

BY KAZUAKI KADONOSONO, MD

Advantages of the Ultravit High Speed Cutter

Figure 1. Retinal movement between 7500 and 5000 cpm.

Figure 2. The 25+ 7500 cpm Ultravit probe duty cycle comparison.

Page 10: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM

10 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014

WOUND CLOSUREPravin U. Dugel, MD: Small-gauge instrumentation is

recommended for wound closure. Can you give us some tips you have learned in the past few years using this technology?

Maria H. Berrocal, MD: I do everything related to wound closure with 25- or 27-gauge probes. With the 25-gauge probe, I like leaving a small amount of air at the end, because then I know the wound is closed correctly. With the 25-gauge, I rarely get fluid leakage. When I use 27-gauge, the wound closes beautifully, and the eye looks almost like nothing has happened to it. Patients love it and think I have great hands, but it really is the technology.

Dr. Dugel: I agree. With a 27-gauge probe, as with the 25-gauge, there are fewer problems with wound leakage because of the smaller incision. Nonetheless, this design is very useful, because now we have a linear cut. I still angle the incisions, however.

FLUIDICS AND INTRAOPERATIVE PRESSURE CONTROL

Dr. Dugel: Do you use intraoperative pressure (IOP) control in all cases, and how has that helped?

Dr. Berrocal: Yes, I do use it in all cases. I have been per-forming vitreoretinal surgery for over 20 years, and in the past, bleeding was common, and so I would raise the bottle height. But then I would have no idea what the IOP was. Many of these cases resolved, but then 2 or 3 years later, the patient had optic nerve damage and poor vision, and I was not exactly sure why this occurred.

In eyes with advanced glaucoma, I let the IOP drop very low, maybe even to 10 mm Hg or less. That way, I know I am not damaging the optic nerve.

SILICONE OILDr. Dugel: How do you use silicone oil in complex cases?

Dr. Berrocal: I have not tried using it with the 27-gauge probes, but I always use it with 25-gauge ones. What is beautiful about the Constellation Vision System

(Alcon) is that it allows you to perform simultaneous silicone injection and active aspiration, which is crucial if you are doing a direct silicone oil-perfluorocarbon exchange.

Kazuaki Kadonosono, MD: I have not done many cases with silicone oil and 27-gauge probes, but I will use silicone oil with 25-gauge probes.

ENVISIONING FUTURE INSTRUMENTATIONDr. Dugel: What is an instrument you would like to

get your hands on?

Dr. Berrocal: I would like an illuminated cutter. As a minimalist, I imagine I could conceivably do a simple case and use the other hand for all sorts of other things.

Dr. Dugel: I think we are on the tip of a surgical revolution as vitreoretinal surgery gets smaller and less invasive. The current innovations will really change every-thing we do. In 10 years from now, do you think we will be talking about smaller instrumentation?

Dr. Berrocal: That question makes me recall a meet-ing in 2004 in which everyone was arguing about how bad microincisional technology was. Someone said, “The ideas come first, and the technology will follow.” Considering that, I think the smaller instrumentation will become more rigid and will enable us to do more maneuvers. Although this is anecdotal, I think we are already achieving better outcomes with the emerging technology. Ever since I started using smaller instrumen-tation, I have not had to deal with dialysis, sclerotomies, or white optic nerves. In the future, I think the technol-ogy will get even better.

Dr. Kadonosono: I was the first surgeon in Japan to use 25-gauge instruments. Everybody criticized me for it initially, but it is now 5 years later, and times have changed. Taking this into consideration, I think 27-gauge probes may follow the same arc of adoption. There may be smaller gauges in the future, and it is hard to predict the future and imagine what will be available. n

Question & Answer Session

Page 11: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost

CONSTELLATION® System with PUREPOINT® Laser Brief Statement

Caution: Federal law restricts this device to sale by, or on the order of, a physician.

Indications for Use: The CONSTELLATION® Vision System is an ophthalmic microsurgical system that is indicated for both anterior segment (i.e., phacoemulsifi-cation and removal of cataracts) and posterior segment (i.e., vitreoretinal) ophthalmic surgery.

The ULTRAVIT® Vitrectomy Probe is indicated for vitreous cutting and aspiration, membrane cutting and aspiration, dissection of tissue and lens removal. The valved entry system is indicated for scleral incision, canulae for posterior instrument access and venting of valved cannulae. The infusion cannula is indicated for posterior segment infusion of liquid or gas.

The PUREPOINT® Laser is indicated for use in photocoagulation of both anterior and posterior segments of the eye including: • Retinal photocoagulation, panretinal photocoagulation and intravitreal endophotocoagulation of vascular and structural abnormalities of the retina and cho-

roid including: Proliferative and nonproliferative retinopathy (including diabetic); choroidal neovascularization secondary to age-related macular degenera-tion; retinal tears and detachments; macular edema, retinopathy of prematurity; choroidal neovascularization; leaking microaneurysms.

• Iridotomy/Iridectomy for treatment of chronic/primary open angle glaucoma, acute angle closure glaucoma and refractory glaucoma.• Trabeculoplasty for treatment of chronic/primary open angle glaucoma and refractory glaucoma.• And other laser treatments including: internal sclerostomy; lattice degeneration; central and branch retinal vein occlusion; suturelysis; vascular and pigment

skin lesions.

The FlexTip* laser probe is intended to be used with ALCON® 532nm laser systems.

Contraindications: • Patients with a condition that prevents visualization of target tissue (cloudy cornea, or extreme haze of the aqueous humor of the anterior chamber of vitre-

ous humor) are poor candidates for LIO delivered laser treatments.• The infusion cannula is contraindicated for use of oil infusion.

Complications: Corneal burns, inflammation, loss of best-corrected visual acuity, loss of visual field and transient elevations in intraocular pressure can occur as a result of ophthalmic laser treatment. Unintentional retinal burns can occur if excessive treatment beam power or duration is used.

Warnings and Precautions: • The disposables used in conjunction with ALCON® instrument products constitute a complete surgical system. Use of disposables and handpieces other

than those manufactured by Alcon may affect system performance and create potential hazards. • Attach only Alcon supplied consumables to console and cassette luer fittings. Do not connect consumables to the patient›s intravenous connections.• Mismatch of consumable components and use of settings not specifically adjusted for a particular combination of consumable components may create a

patient hazard.• Vitreous traction has been known to create retinal tears and retinal detachments.• The closed loop system of the CONSTELLATION® Vision System that adjusts IOP cannot replace the standard of care in judging IOP intraoperatively. If the

surgeon believes that the IOP is not responding to the system settings and is dangerously high or low, this may represent a system failure. Note: To ensure proper IOP Compensation calibration, place infusion tubing and infusion cannula on a sterile draped tray at mid-cassette level during the priming cycle.

• Leaking sclerotomy may lead to post operative hypotony.• Back scattered radiation is of low intensity and is not harmful when viewed through a protective filter. All personnel in the treatment room must wear protec-

tive eyewear, OD4 or above at 532nm, when the system is in Standby/Ready mode as well as during treatment. The doctor protection filter is an OD greater than 4 at 532nm.

Attention: Please refer to the CONSTELLATION® Vision System Operators Manual for a complete listing of indications, warnings, and precautions.

*Trademarks are property of their respective owners.

CON12290PI

MIVS Important Product Information

Caution: Federal law restricts this device to sale by, or on the order of, a physician.

Indications for Use: The CONSTELLATION® Vision System is an ophthalmic microsurgical system that is indicated for both anterior segment (i.e., phacoemulsifica-tion and removal of cataracts) and posterior segment (i.e., vitreoretinal) ophthalmic surgery.

The ULTRAVIT® Vitrectomy Probe is indicated for vitreous cutting and aspiration, membrane cutting and aspiration, dissection of tissue and lens removal. The valved entry system is indicated for scleral incision, canulae for posterior instrument access and venting of valved cannulae. The infusion cannula is indicated for posterior segment infusion of liquid or gas.

Warnings and Precautions: • The infusion cannula is contraindicated for use of oil infusion.• Attach only Alcon supplied products to console and cassette luer fittings. Improper usage or assembly could result in a potentially hazardous condition for

the patient. Mismatch of surgical components and use of settings not specifically adjusted for a particular combination of surgical components may affect system performance and create a patient hazard. Do not connect surgical components to the patient’s intravenous connections.

• Each surgical equipment/component combination may require specific surgical setting adjustments. Ensure that appropriate system settings are used with each product combination. Prior to initial use, contact your Alcon sales representative for in-service information.

• Care should be taken when inserting sharp instruments through the valve of the Valved Trocar Cannula. Cutting instrument such as vitreous cutters should not be actuated during insertion or removal to avoid cutting the valve membrane. Use the Valved Cannula Vent to vent fluids or gases as needed during injection of viscous oils or heavy liquids.

• Visually confirm that adequate air and liquid infusion flow occurs prior to attachment of infusion cannula to the eye.• Ensure proper placement of trocar cannulas to prevent sub-retinal infusion.• Leaking sclerotomies may lead to post operative hypotony.• Vitreous traction has been known to create retinal tears and retinal detachments.• Minimize light intensity and duration of exposure to the retina to reduce the risk of retinal photic injury.

ATTENTION: Please refer to the CONSTELLATION® Vision System Operators Manual for a complete listing of indications, warnings and precautions.

GAU13048PI

CONSTELLATION Vision System, ULTRAVIT High Speed 25+ Probe, and ULTRAVIT High Speed 27+ Probe are trademarks of Novartis. © Novartis 2014. All other brand/product names are the trademarks of their respective owners.

VIT14139JS

Page 12: HIGHLIGHTS FROM THE “FASTER AND SMALLER” · HIGHLIGHTS FROM THE “FASTER AND SMALLER” SYMPOSIUM 4 SUPPLEMENT TO RETINA TODAY NOVEMBER/DECEMBER 2014 attraction required almost