Page 1: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

High Quality Pipette Tipsfor Consistent and Reliable Results

Page 2: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Excellence in Quality and Convenience

Sartorius pipette tips meet the highest quality and purity standards.

Sartorius tips are designed and manufactured to fit Sartorius pipettes perfectly, enabling maximum tip sealing and accuracy. This combination guarantees the highest performance and precision for your pipetting needs. Moreover, correctly fitting tips protect the pipette’s tip cone from wear and tear.

Sartorius tip packages are designed to make the daily work of lab rofessionals easier. Our offering covers a variety of functional tip package options with various purity ratings.

The high purity and consistent quality of Sartorius tips provide your valuable samples with the ultimate protection from contamination. We adhere to strict quality standards and control procedures - from raw material to automated manufacturing and packaging.

Pure Quality

l Tips are manufactured using a fully automated process in ISO class 8 cleanroom conditions to ensure purity

l Strict standards, followed from R&D to production and delivery: ISO 9001, ISO 140001, and ISO 13485

l Every batch of purity certified tips is tested and verified as free of DNase, RNase, and endotoxins

l Using Sartorius tips with Sartorius pipettes guarantees perfect tip sealing, ensuring reliable results with high precision and accuracy

l Tip-purity certificates can be easily downloaded from our website, www.sartorius.com

l Tips are manufactured using virgin polypropylene without any additives

Page 3: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Fully Compliant

l Every tip package is clearly marked with the volume, colour code, purity grade, expiry date, product code, and lot number

l The lot number enables full traceability right from production

l CE | IVD compliant when used with Sartorius pipettes

Convenient

l Smart color codes make it quick and easy to find the right tip for your pipette

l Versatile package options are available for various needs

l Sartorius pipettes feature Optiload® and Optiject® functions for smooth tip attachment and ejection

l Pre-sterilized tips are available for demanding applications

l Compatible with most pipette brands

Page 4: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Optifit Tips – Standard Multipurpose Tips for Various ApplicationsOptifit Tips are high-quality standard tips and an excellent solu-tion for various applications. Non-filter Optifit Tips are available in various purity levels and package options, and are suitable for use with other manufacturers’ pipettes. Optifit Tips are also fully autoclavable at 121°C for 20 minutes with 1 bar/100 kPa pressure.

Optifit Tip Range - Extended and wide-bore tips for specific applications

- Pre-sterilized and non-sterile

- Purity certified Single Tray racks and Refill Packs

- Single Tray racks, Refill Packs, Refill Towers and Bulk packages

- Volume range from 10 µl to 10 ml

SafetySpace Filter Tips – Filter Tips for Contamination ProtectionSafetySpace Filter Tips help prevent cross-contamination of your sample and pipette, and reduce the need for pipette maintenance. Sartorius SafetySpace Filter Tips have more space between the sample and the filter than conventional filter tips, which prevents the risk of the sample coming into contact with the filter. The filter is made of polyethylene and does not include any self- sealing additives.

SafetySpace Filter Tips provide protection from contamination for pipettes and samples in the following applications:

- Molecular biology

- Microbiology

- Cell cultivation

- Radioactive lab work

SafetySpace Filter Tip Range - Pre-sterilized

- Purity certified

- Single Tray racks

- Volume range from 10 to 1,200 µl

High Quality Tips for Various Pipetting Applications

Page 5: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Unique SafetySpace FeatureSafetySpace Filter Tips have additional space between the sample and filter. Any liquid types and pipetting techniques can be applied without the risk of the liquid permeating the filter.The extra space is particularly beneficial in the following applications:

- Pipetting foaming liquids such as buffers and proteins

- When using electronic pipettes with multiple dispensing functions

- Reverse pipetting

The four Low Retention Tips on the right retain only minimum residual liquid.

Low Retention Tips – Hydrophobic Tips for Maximum Sample RecoveryLow Retention Tips maximize sample recovery and the accuracy of results when pipetting detergent containing solutions or other liquids with low surface tension. Using patented Sartorius technology, we can manufacture tips with fully hydrophobic and highly liquid-repellent surfaces.Low Retention Tips offer excellent chemical resistance without any leachables.

Low Retention Tips are advantageous, for example, in sensitive molecular biology applications, where reagents often contain viscous substances and detergents. These applications include, for example:

- PCR and real-time PCR

- Cloning, sequencing, and other DNA and RNA techniques

- SDS-PAGE and other protein analysis methods

- Protein purification techniques

Low Retention Tip Range - Filter (SafetySpace) and non-filter (Optifit) tips

- Pre-sterilized and non-sterile

- Single Tray racks and Refill Towers

- Range of volumes from 10 to 1,200 µl

SafetySpace – the additional space between the sample and filter.

Page 6: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

A Convenient Range of Package Options

Refill PacksThe fast and easy way to refill empty Single Tray racks.

Sartorius tip packages are designed to make the daily work of lab professionals easier. Our offering covers a variety of functional tip packages with various purity ratings.

Smart color codes make it quick and easy to find exactly the right tip for your pipette. The trays, racks, and non-filter tips are fully autoclavable for 20 minutes at 121°C and 1 bar/100 kPa. All tips, trays, and racks are made of 100% pure polypropylene and are recyclable as energy waste.

Single Tray Racks- 96 tips in convenient and reusable tray racks

- Each batch is certified as free of DNase, RNase, and endotoxins

- Informative rack labelling enables easy tip identification and traceability

- Hermetically sealed plastic wrapping ensures purity

- Empty racks can be easily reloaded with tips from Refill Towers and Packs

Refill Tower- Reuse and reload empty racks easily

- Save space: 10x96 tips in each tower

- Available in the most widely used tip sizes: 10 µl, 200 µl, and 350 µl

- 100% recyclable cardboard package

Refill Packs- Reuse and reload empty racks easily

- Each batch is certified as free of DNase, RNase, and endotoxins

- Individually packed hermetically sealed tip trays for maximum purity

- Pre-sterilized option available

Page 7: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

FlexiBulk®

- Fast and convenient reloading of racks due to orderly packed tips.

- Compact and airtight resealable plastic package

Bulk in a Box- Economical resealable bag of tips in cardboard packaging

- Available in 10 µl, 5 ml, and 10 ml

Bulk PacksBulk packages of high-quality tips

Page 8: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Optifit Tips and Optifit Low Retention Tips

Package Single Tray (10 × 96 tips) Refill Pack Refill Tower (10 × 96 tips) FlexiBulk® Bulk in a Box

Low Retention Low Retention Low Retention

Purity Free of DNase, RNase, endotoxins

Free of DNase, RNase, endotoxins

Free of DNase, RNase, endotoxins

0,1 – 10 µl, 31.5 mm Non-sterile 790010 LH-L790010 790012 LH-L790012 790014 (1,000 tips)

Pre-sterilized 790011 790013 (20 × 96 tips)

0,1 – 10 µl Extended

46 mm Non-sterile 783210

Pre-sterilized 783211

0,5 – 200 µl 51 mm Non-sterile 790200 LH-L790200 790202 LH-L790202 LH-B790204 (960 tips)

Pre-sterilized 790201 790203 (15 × 96 tips)

5 – 350 µl 54 mm Non-sterile 790350 LH-L790350 790352 LH-L790352 LH-B790354 (960 tips)

Pre-sterilized 790351 790353 (15 × 96 tips)

10 – 1,000 µl 71.5 mm Non-sterile 791000 LH-L791000 791002 (10 × 96 tips) LH-B791004 (480 tips)

Pre-sterilized 791001 791003 (10 × 96 tips)

10 – 1,000 µl Wide bore

68.5 mm Non-sterile 791020 LH-B791204 (480 tips)

Pre-sterilized 791021

50 – 1,200 µl 71.5 mm Non-sterile 791200 LH-L791200 791202 (10 × 96 tips) LH-B791204 (480 tips)

Pre-sterilized 791201 791203 (10 × 96 tips)

50 – 1,200 µl Extended

90 mm Non-sterile 791210 LH-L791210 791212 (10 × 96 tips)

Pre-sterilized 791211 791213 (10 × 96 tips)

100 – 5,000 µl 150 mm Non-sterile 780304 (50 tips) 780300 (100 tips) 780308 (1,000 tips)

Pre-sterilized 780305 (50 tips)

1 – 10 ml 155 mm Non-sterile LH-780316 (250 tips)

Ordering Information

Page 9: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Optifit Tips and Optifit Low Retention Tips

Package Single Tray (10 × 96 tips) Refill Pack Refill Tower (10 × 96 tips) FlexiBulk® Bulk in a Box

Low Retention Low Retention Low Retention

Purity Free of DNase, RNase, endotoxins

Free of DNase, RNase, endotoxins

Free of DNase, RNase, endotoxins

0,1 – 10 µl, 31.5 mm Non-sterile 790010 LH-L790010 790012 LH-L790012 790014 (1,000 tips)

Pre-sterilized 790011 790013 (20 × 96 tips)

0,1 – 10 µl Extended

46 mm Non-sterile 783210

Pre-sterilized 783211

0,5 – 200 µl 51 mm Non-sterile 790200 LH-L790200 790202 LH-L790202 LH-B790204 (960 tips)

Pre-sterilized 790201 790203 (15 × 96 tips)

5 – 350 µl 54 mm Non-sterile 790350 LH-L790350 790352 LH-L790352 LH-B790354 (960 tips)

Pre-sterilized 790351 790353 (15 × 96 tips)

10 – 1,000 µl 71.5 mm Non-sterile 791000 LH-L791000 791002 (10 × 96 tips) LH-B791004 (480 tips)

Pre-sterilized 791001 791003 (10 × 96 tips)

10 – 1,000 µl Wide bore

68.5 mm Non-sterile 791020 LH-B791204 (480 tips)

Pre-sterilized 791021

50 – 1,200 µl 71.5 mm Non-sterile 791200 LH-L791200 791202 (10 × 96 tips) LH-B791204 (480 tips)

Pre-sterilized 791201 791203 (10 × 96 tips)

50 – 1,200 µl Extended

90 mm Non-sterile 791210 LH-L791210 791212 (10 × 96 tips)

Pre-sterilized 791211 791213 (10 × 96 tips)

100 – 5,000 µl 150 mm Non-sterile 780304 (50 tips) 780300 (100 tips) 780308 (1,000 tips)

Pre-sterilized 780305 (50 tips)

1 – 10 ml 155 mm Non-sterile LH-780316 (250 tips)

Page 10: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Low Retention Tips

S a r t o r i u s

LowRet

Ordering Information

SafetySpace Filter Tips and SafetySpace Low Retention Tips Package Single Tray (10 × 96 tips)

Low Retention Low Retention

Purity Free of DNase, RNase, endotoxins

Free of DNase, RNase, endotoxins

0.1 – 10 µl 3.5 mm Pre-sterilized 790011F LH-LF790011

0.5 – 20 µl 51 mm Pre-sterilized 790021F LH-LF790021

2 – 120 µl 51 mm Pre-sterilized 790101F LH-LF790101

5 – 200 µl 52.5 mm Pre-sterilized 790201F LH-LF790201

5 – 300 µl 52.5 mm Pre-sterilized 790301F LH-LF790301

50 – 1,000 µl 78 mm Pre-sterilized 791001F LH-LF791001

50 – 1,200 µl 90 mm Pre-sterilized 791211F LH-LF791211

0,1 – 10 µl Extended, with standard air gap

46 mm Pre-sterilized 783201

Page 11: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Safe-Cone Filters act as a final barrier to prevent any fluids and liquid vapors from coming into contact with the internal components of the pipette. These unique and replaceable filters are made of polyethylene (PE). They:

- protect the pipette and sample from contamination

- prolong the pipette’s lifetime

- reduce maintenance intervals

Safe-Cone Filters cannot be used together with filter tips.

Plus FilterFor more demanding applications such as radioactive work, cell culture, bacterial and virological work, and molecular biology.

Standard FilterFor general applications. These filters can be used for the same applications as the Plus filter, but need to be changed more frequently.

Safe-Cone Filters

Order Code Item Qty / Unit

721008 Standard d 2.51 mm PE 50721007 Standard d 3.15 mm PE 50721006 Standard d 5.33 mm PE 50721005 Standard d 6.73 mm PE 50721014 Standard d 1.83 mm PE 50721018 Plus d 2.51 mm PE 50721017 Plus d 3.15 mm PE 50721016 Plus d 5.33 mm PE 50721015 Plus d 6.73 mm PE 50

PE = polyethylene

Protect Your Pipette and Sample with Safe-Cone Filters

Removing the Safe-Cone Filter

Page 12: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Customer needs are always the starting point when developing and manufacturing Sartorius pipettes and pipette tips. As our customers have their own unique preferences and because pipetting needs vary between applications and users, we provide our customers with liquid handling equipment that matches their applications precisely and fulfills even the strictest quality standards. Ergonomics, performance, and reliability are the cornerstones of our design and product development processes. Strong technical innovation and the latest design and manufacturing technologies ensure the high quality and performance of our products.

Sartorius has a rich and extensive history in liquid handling. Our experience and know-ledge of pipette and pipette tip design has resulted in several award-winning innovations and products. The Sartorius liquid handling competence center masters the entire value chain, from customer needs and product design to manufacturing. Our in-house R&D capabilities with experienced liquid handling experts enable continuous product and process development and the creation of new, innovative solutions. Designing Sartorius tips goes beyond mere tip geometry: our R&D team also designs the tip molds in order to ensure the highest possible quality and consistency.

Sartorius has modern production facilities for pipettes and tips. Our highly automated tip manufacturing facility allows us to maintain the highest quality and purity standards by selecting the best plastic materials and controlling the manufacturing process from beginning to end. Our quality management system follows not only ISO 9001 and ISO 14001, but also ISO 13485. Tip production also complies with the ISO 14644-1 standard, in order to fulfill ISO Class 8 cleanroom conditions for guaranteed tip purity.

Sartorius Design and R&D – The Driving Force Behind Our High-Quality Products

Page 13: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Electronic Pipettes 1-ch 8 & 12-ch 1-ch 8 & 12-ch

Colour Code

µl

0,2-

10

5-12

0

10-3

00

50-1

,000

100-

5,00

0

500-

10,0

00

0,2-

10

5-12

0

10-3

00

50-1

,200

0,1-

5

0,2-

10

5-12

0

10-3

00

50-1

,000

100-

5,00

0

0,2-

10

5-12

0

10-3

00

50-1

,200

Optifit Tips 0,1-10

0,1-10 Ext.

0,5-200

5-350

10-1,000

10-1,000 WB

50-1,200

50-1,200 Ext.

100-5,000

1-10 ml SafetySpace Filter Tips

0,1-10

0,1-10 Ext.*

0,5-20

2-120

5-200

5-300

50-1,000

50-1,200 Note: Low Retention Tips are available in volumes up to 1,200 µl.*Filter tip with standard air gap. In tests, 10 µl extended tip’s systematic error and random error results, deviated slightly from those of the 10 µl tip.

Picus® and Picus® NxT eLINE®

Ensure the Highest Pipetting Performance and Precision

Sartorius tips are designed and manufactured to perfectly fit with Sartorius pipettes enabling maximum tip sealing and accuracy.

Pipette Tip Selection Guide

Page 14: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Mechanical Pipettes 1-ch 8 & 12-ch 1-ch 8 & 12-ch

Colour Code

µl

0,1-

3

0,5-

10

2-20

10-1

00

20-2

00

100-

1,00

0

500-

5,00

0

1-10

ml

0,5-

10

5-10

0

30-3

00

0,1-

3

0,5-

10

2-20

5-50

10-1

00

20-2

00

100-

1,00

0

500-

5,00

0

1-10

ml

0,5-

10

10-1

00

30-3

00

Optifit Tips 0,1-10

0,1-10 Ext.

0,5-200

5-350

10-1,000

10-1,000 WB

50-1,200

50-1200 Ext.

100-5,000

1-10 ml SafetySpace Filter Tips

0,1-10

0,1-10 Ext.*

0,5-20

2-120

5-200

5-300

50-1,000

50-1,200 Note: Low Retention Tips are available in volumes up to 1,200 µl.* Filter tip with standard air gap. In tests, 10 µl extended tip’s systematic error and random error results, deviated slightly from those of the 10 µl tip.

Tacta® and mLINE® Proline® Plus

Ensure the Highest Pipetting Performance and Precision

Sartorius tips are designed and manufactured to perfectly fit with Sartorius pipettes enabling maximum tip sealing and accuracy.

Pipette Tip Selection Guide

Page 15: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Ergonomic and Reliable Sartorius Pipettes

Sartorius pipettes provide the perfect solution for your liquid handling needs. Sartorius pipettes and tips fit seamlessly together and provide you with maximum pipetting perfor-mance and exact accuracy and precision. Sartorius offers the leading range of superior electronic and mechanical pipettes. For more information, visit www.sartorius.com.Sartorius also provides pipette maintenance, repair, and calibration services globally. Contact your nearest Sartorius service center or office for more information.

Proline®

Mechanical Pipettes 1-ch 8 & 12-ch

Colour Code

µl

0,1-

2,5

0,5-

10

2-20

5-50

10-1

00

20-2

00

100-

1,00

0

1,00

0-5,

000

0,5-

10

5-50

50-3

00

Optifit Tips 0,1-10

0,1-10 Ext.

0,5-200

5-350

10-1,000

10-1,000 WB

50-1,200

50-1,200 Ext.

100-5,000

1-10 ml

SafetySpace Filter Tips

0,1-10

0,1-10 Ext.*

0,5-20

2-120

5-200

5-300

50-1,000

50-1,200

Page 16: High Quality Pipette Tips for Consistent and Reliable Results · The four Low Retention Tips on the right retain only minimum residual liquid. Low Retention Tips – Hydrophobic Tips

Additive-free Manufacturing tips from pure virgin polypropylene minimizes the risk of substances from the tip material leaching into samples. This is why Sartorius tips are free of colours, clarifying agents, and plasticizers.

DNase-free DNases are powerful enzymes (nucleases) that degrade DNA by hydrolyzing it into short fragments. Even trace amounts of DNases can lead to low or no yields in DNA techniques such as PCR. DNase contamination sources are human contact and bacteria. DNase-free tips are tested for DNase activity with fluorometric assay by detecting degradation of labeled DNase substrate. DNase-free pipette tips show no evidence of DNase activity in the assay with a detection level of <6,25*10-5 U/µl when DNase I was used as a standard.

Endotoxin-free Endotoxins are lipopolysaccharides that are part of the outer membrane of Gram-negative bacteria. They cause fever in humans and impair the growth of cell cultures. Endotoxins are very durable and are present wherever bacteria are able to grow, i.e. air, water, soil, skin, raw materials, and in any non-sterile environ-ment. When certified endotoxin free, the tips are tested according to FDA guidelines for medical devices. The Ph. Eur. 2.6.14, Method D. Validated test result for endotoxin-free tips is < 0,005 IU/ml (EU/ml).

RNase-free RNases are enzymes that catalyze the degradation of RNA into short fragments. These very stable enzymes are difficult to remove and originate from human skin, hair, and saliva, as well as from bacteria. Tips are tested for RNase activity using fluorometric assay. RNase-free tips show no evidence of RNase activity with a detection level of <3,125*10-9 U/µl when RNase A was used as a standard.

Sterilization The destruction of all microbial life, including bacterial endospores. Sterility can be accomplished using, for example, steam, heating, chemicals, or radiation. Sartorius pre-sterilized tips are sterilized with an electron beam (beta irradiation) in accordance with EN 552 and ISO 11137, and the process is validated by using 25 kGy as the minimum dose, with an SAL (sterility assurance level) of 10-6.

Sartorius ABC of Tip PurityEuropeGermanySartorius Lab Instruments GmbH & Co. KGOtto-Brenner-Strasse 2037079 Goettingen

Phone +49.551.308.0

France & Suisse RomandeSartorius France2, rue Antoine Laurent de LavoisierZA de la Gaudrée91410 Dourdan

Phone +33.1.70.62.50.00

AustriaSartorius Austria GmbHModecenterstrasse 221030 Vienna

Phone +43.1.7965760.0

BelgiumSartorius Belgium N.V.Rue Colonel Bourg 1051030 Bruxelles

Phone +32.2.756.06.90

Finland & BalticsSartorius Biohit Liquid Handling OyLaippatie 100880 Helsinki

Phone +358.9.755.951

HungarySartorius Hungária Kft.Kagyló u. 5.2092 Budakeszi

Phone +3623.457.227

IrelandSartorius Ireland Ltd.Unit 41, The Business CentreStadium Business ParkBallycoolin RoadDublin 11

Phone +353.1.8089050

ItalySartorius Italy S.r.l. Via Torino 3/520814 Varedo (MB)

Phone +39.0362.5557.11

NetherlandsSartorius Netherlands B.V.

Phone +31.30.60.53.001

[email protected]

PolandSartorius Poland sp.z o.o.ul. Wrzesinska 7062-025 Kostrzyn

Phone +48.61.6473830

Russian FederationLLC “Sartorius RUS”Vasilyevsky Island5th line 70, Lit. A199178 St. Petersburg

Phone +7.812.327.53.27

Spain & PortugalSartorius Spain, S.A.Avda. de la Industria, 32Edificio PAYMA28108 Alcobendas (Madrid)

Phone Spain +34.913.586.095Phone Portugal +351.800.855.800

SwitzerlandSartorius Mechatronics Switzerland AGRingstrasse 24a8317 Tagelswangen (ZH)

Phone +41.44.746.50.00

U.K.Sartorius UK Ltd.Longmead Business CentreBlenheim Road, EpsomSurrey KT19 9QQ

Phone +44.1372.737159

UkraineLLS “Sartorius RUS”Post Box 440 “B”01001 Kiev, Ukraine

Phone +380.44.411.4918

AmericasUSASartorius Corporation5 Orville Drive, Suite 200Bohemia, NY 11716

Phone +1.631.254.4249Toll-free +1.800.635.2906

ArgentinaSartorius Argentina S.A.Int. A. Ávalos 4251B1605ECS MunroBuenos Aires

Phone +54.11.4721.0505

BrazilSartorius do Brasil Ltda Avenida Senador Vergueiro 2962 São Bernardo do Campo CEP 09600-000 - SP- Brasil

Phone +55.11.4362.8900

CanadaSartorius Canada Inc1173 North Service Road West, D4Oakville, ON L6M 2V9

Phone +1.905.569.7977Toll-Free +1.800.668.4234

MexicoSartorius de México, S.A. de C.V.Libramiento Norte de Tepotzotlan s/n,Colonia Barrio Tlacateco,Municipio de Tepotzotlan,Estado de México,C.P. 54605

Phone +52.55.5562.1102

[email protected]

PeruSartorius Peru S.A.C.Avenue Alberto del Campo 411 Floor 12 – The Office15076 – San Isidro, Lima

Phone +51.1.441 0158

Asia|PacificAustraliaSartorius Australia Pty. Ltd.Unit 5, 7-11 Rodeo DriveDandenong South Vic 3175

Phone +61.3.8762.1800

ChinaSartorius (Shanghai) Trading Co., Ltd.3rd Floor, North Wing, Tower 1No. 4560 Jinke RoadZhangjiang Hi-Tech Park Pudong DistrictShanghai 201210, P.R. China

Phone +86.21.6878.2300

Hong KongSartorius Hong Kong Ltd.Unit 1012, Lu Plaza2 Wing Yip StreetKwun TongKowloon, Hong Kong

Phone +852.2774.2678

IndiaSartorius Weighing India Pvt. Ltd.#69/2-69/3, NH 48, Jakkasandra,Nelamangala Tq562 123 Bangalore, India

Phone +91.80.4350.5250

JapanSartorius Japan K.K.4th Fl., Daiwa Shinagawa North Bldg.8-11, Kita-Shinagawa 1-chomeShinagawa-ku, Tokyo, 140-0001 Japan

Phone +81.3.3740.5408

MalaysiaSartorius Malaysia Sdn. BhdLot L3-E-3B, Enterprise 4 Technology Park MalaysiaBukit Jalil57000 Kuala Lumpur, Malaysia

Phone +60.3.8996.0622

SingaporeSartorius Singapore Pte. Ltd10 Science Park Rd The Alpha #02-13/14Singapore Science Park IISingapore 117684

Phone +65.6872.3966

South KoreaSartorius Korea Ltd.8th Floor, Solid Space B/D, PanGyoYeok-Ro 220, BunDang-Gu SeongNam-Si, GyeongGi-Do, 463-400

Phone +82.31.622.5700

ThailandSartorius (Thailand) Co. Ltd.129 Rama 9 Road,HuaykwangBangkok 10310

Phone +66.2643.8361-6

Sales and Service ContactsFor further contacts, visit www.sartorius.com

www.sartorius.com

Sartorius Lab Instruments GmbH & Co. KGOtto-Brenner-Strasse 2037079 Goettingen, GermanyPhone +49.551.308.0www.sartorius.com

USA Toll-free +1.800.635.2906UK +44.1372.737159France +33.1.70.62.50.00Italy +39.0362.5557.11Spain +34.913.586.095Russian Federation +7.812.327.53.27Japan +81.3.3740.5408

Specifications subject to change without notice. Copyright Sartorius Lab Instruments GmbH & Co. KG. Printed in the EU on paper bleached without chlorine.Publication No.: Order No.: Ver. 01 | 2017

Specifications subject to change without notice. Copyright Sartorius Lab Instruments GmbH & Co. KG. Printed in the EU on paper bleached without chlorine.Publication No.: LLH1506-e180301Order No.: 98649-022-64 Ver. 03 | 2018