C O M P O N E N T S
High power contactorType BMS09.15 / BMS18.15 BMS09.18 / BMS18.18
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.182
GENERAL INFORMATION
APPLICATIONS, TYPICAL EXAMPLES
The BMS contactor, with more than one hundred and fifty thousand units in operation worldwide, is a contactor valued by the car builders and operators of electric traction vehicles for its strong performance level and its extremely high reliability.
Taking advantages of its recognized features and design, Sécheron has modernized the BMS to make a product platform particularly well adapted to actual requirements and standards.
With its high modularity, the BMS offers variants and options that enable our customers to find the most appropriate version to fit their application, either as a stand-alone contactor, or delivered coupled with a Sécheron dedicated pre-charging contactor type PCC18.
Power contactor modules, convenient to order and easy to install, are a frequent wish of our customers. Sécheron brings the best solution with “plug & play” units gathering line and pre-charging contactors, but also current measurement and customised high voltage and low voltage interfaces.
MAIN FEATURES
• Line contactors, assembled set of line and pre-charging contactors, for DC vehicles.
• Separation/line contactors assembled set of line and pre-charging contactors, for AC vehicles.
• Other applications for locomotives and trains.
• Contactors for dc traction power substations and other industrial fields.
• Normally open and bi-directional contactor.• Rated operation voltage 900 VDC or 1’800 VDC/AC.• Conventional free air thermal current 1'500 A or 1'800 A.• Available in 1 pole (2 poles is under-development).
• Low voltage control coil protection against surges.• Suitable for ambient temperature from -40°C to +70°C.• Reference standards: EN/IEC60077-1/-2, EN/IEC61373, EN45545.
DC TRACTION VEHICLE
~
M
M
Power line
Traction convertersDC circuit-breaker
Current collector
3
33
~3
PCC18
BMS
PCC18
BMS
M
M
Traction converters
Power line
~
~~3
~3
AC circuit-breaker
Main transformer
Current collector
PCC18
BMS
BMS
3
3
~
M
M
Power line
Traction convertersDC circuit-breaker
Current collector
3
33
~3
PCC18
BMS
PCC18
BMS
M
M
Traction converters
Power line
~
~~3
~3
AC circuit-breaker
Main transformer
Current collector
PCC18
BMS
BMS
3
3
AC TRACTION VEHICLE
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.18 3
Ue [V]
900
1800
1’500Ue [V]
1800
Ith [A]
1’800
BMS..18- 1 pole
PCC18 for horizontal mounting only
BMS..15- 1 pole
All arc chutes are compatible with the BMS bodies below
BM
S
PC
C1
8
CONTACTOR CONFIGURATIONS
BM
S A
rc C
hute
BM
S B
od
yP
re-c
harg
ing
cont
acto
r
MAIN BENEFITSMAIN BENEFITS Compact size and low weight.
No critical current.
Different arc chutes matching installation space and operational performance requirements.
High modularity of the range.
Possible integration of optional pre-charging contactor type PCC18 directly on BMS line contactor.
Low maintenance requirements with easy access to the main contacts for replacement.
Worldwide service proven.
Type A (VDC)
Type A (VDC)
Type A (VAC)
Type B (VDC)
Type B (VDC)
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.184
DATA FOR PRODUCT SELECTION
2’300
800/C1
MAIN HIGH VOLTAGE CIRCUIT Symbol Unit BMS 09.15
BMS 09.18
BMS 09.15
BMS 09.18
BMS 18.15
BMS 18.18
BMS 18.15
BMS 18.18 PCC18
Arc chute type A A B B A A B B N.A.
Component category A2Type of main contact Normally OpenNumber of poles 1 pole (2 poles under-development)Rated operational voltage - dc voltage Ue [VDC]
900
1’800
1’800
- ac voltage (16.7, 25, 50/60 Hz) Ue [VAC] 1’800 - - 1’800Rated insulation voltage Ui [VDC] [VAC]
2’300 2’300 -
2’300 2’300
Conventional free air thermal current (1) Ith [A] 1’500 (BMS..15) 1’500 (BMS..15) N.A.
1’800 (BMS..18) 1’800 (BMS..18) N.A.
Rated operational current/operational frequency- Horizontal/Vertical mounting: Ie [ADC] Ie [AAC] 1’500/C2 1’800/C2
1’000/C1 800/C1-
800/C1 1’000/C1-
1’000/C1 N.A.N.A.
Rated short-time withstand current Icm / t [kA]/[ms] 15 / 100 N.A.Peak short-time withstand current Îcw [kA] 18 N.A.Maximum breaking capacity- dc current, τ = 15 ms Ibc [A]- ac current, cos Φ = 0.8 Ibc [Arms]
(16.7, 25 & 50/60 Hz)
3’2004’200
6’000-
2’300-
6’000-
40100
Maximum making capacity- dc current, τ = 15 ms Imc [A]- ac current, cos Φ = 0.8 Imc [Apeak]
(16.7, 25 & 50/60 Hz)
10’0006’000
100200
Rated power-frequency withstand voltage (50 Hz/1min)- Between main contacts (open) U50 [kVrms]- Main circuit (closed) to earth U50 [kVrms]
7.59.5
7.59.5
(1) At Tamb = +40°C for DC and AC voltage up to 60 Hz and tested with HV connections with current density 1.7A/mm2. For higher frequency, please contact Sécheron.
LOW VOLTAGE CIRCUIT
Control circuit
Nominal supply voltage/Nominal control voltage Un / UEF [Vdc] 24 to 110 (2) 24 to 110 (2)
Range of voltage [0.7 - 1.25] Un
Nominal closing power (3) Pc [W] ≤ 200 (2) < 40 (2)
Nominal holding power (3) Ph [W] ≤ 8 (2) -
Mechanical closing time (3) tcc [ms] 120 -
Maximum operating time Top [s] - 10(2) For detailed values based on BMS/PCC configuration, please refer to page 8. • (3) At Un and Tamb = +20°C
Auxiliary contacts
Type of contacts Potential free (PF)Rated voltage [Vdc] 24 to 110Conventional thermal current Ith [A] 10Switching categories according to EN60947
- AC-15 - DC-13
230 VAC 1.0 A 110 VDC 0.5 A
Minimum let-through current at 24 VDC (4) [mA] ≥ 10 (silver contacts) or 4 ≤ I < 10 (gold contacts)(4) For a dry and clean environment.
Low voltage interface
Control circuitsAuxiliary switches
Wago terminalDirect on switch (M3 screws)
Insulation
Rated power-frequency withstand voltage (5)
- LV circuit to earth U50 [kV] 1.5(5) At 50 Hz and during 1 minute.
OPERATING CONDITIONSInstallation Indoor
Altitude [m] < 1’400Working ambient temperature Tamb [°C] -40 to +70Humidity 95% at +40°CPollution degree PD3A
Minimum mechanical durability N Cycles 2 Millions (BMS..15) / 0.5 Million (BMS..18) / 2 Millions (PCC18)
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.18 5
PRODUCT INTEGRATIONMAIN DIMENSIONS
203 (900 VDC/1800 VAC)
1538
8015
HV
105
BMS 09.15 A / 18.15A
BMS 09.18 B / 18.18 BBMS 09.15 B / 18.15 B
BMS xx.15
122
BMS 09.15 A
BMS 09.18 A
BMS 18.15 A
BMS 18.18 A
BMS 09.15 B
BMS 09.18 B
BMS 18.15 B
BMS 18.18 B
270
327
(900
VD
C)
395
(180
0 V
DC)
97
128
97
128
97
128
400
BMS 09.18 A / 18.18A
1538
8015
400
27.5
363 (1800 VDC)
37 37
HV
LV WAGOterminal
31
1538
8015
HV
210 (900 VDC)
371 (1800 VDC)
33
LV WAGOterminal
122
122
1538
8015
HV
98
ø13.5 × 2
436812
.5
436812
.5 ø13.5 × 2
ø13.5 × 6
107144
203 (900 VDC/1800 VAC)
363 (1800 VDC)
212 (900 VDC)
373 (1800 VDC)
370
(180
0 V
DC)
97
128
123
327
(900
VD
C)
A
B
203 (900 VDC/1800 VAC)
1538
8015
HV
LV WAGOterminal
363 (1800 VDC)
37
B
B
LV WAGOterminal
/// BMS09.15 / BMS18.15 & BMS09.18 / BMS18.18 (ARC CHUTE TYPE A)
1-POLE - HORIZONTAL/VERTICAL INSTALLATION
Dimensions without tolerances are indicative. All dimensions are in mm. The maximum allowed flatness deviation of the support frame is 0.5 mm.
HV connections (BMS..15/BMS..18) : M12 screwsEarth connections : M6 screws
LV connections: - BMS control faston (horizontal) or Wago terminal (vertical) - BMS auxiliary switches M3 screws
203 (900 VDC/1800 VAC)
1538
8015
HV
105
BMS 09.15 A / 18.15A
BMS 09.18 B / 18.18 BBMS 09.15 B / 18.15 B
BMS xx.15
122
BMS 09.15 A
BMS 09.18 A
BMS 18.15 A
BMS 18.18 A
BMS 09.15 B
BMS 09.18 B
BMS 18.15 B
BMS 18.18 B
270
327
(900
VD
C)
395
(180
0 V
DC)
97
128
97
128
97
128
400
BMS 09.18 A / 18.18A
1538
8015
400
27.5
363 (1800 VDC)
37 37
HV
LV WAGOterminal
31
1538
8015
HV
210 (900 VDC)
371 (1800 VDC)
33
LV WAGOterminal
122
122
1538
8015
HV
98
ø13.5 × 2
436812
.5
436812
.5 ø13.5 × 2
ø13.5 × 6
107144
203 (900 VDC/1800 VAC)
363 (1800 VDC)
212 (900 VDC)
373 (1800 VDC)
370
(180
0 V
DC)
97
128
123
327
(900
VD
C)
A
B
203 (900 VDC/1800 VAC)
1538
8015
HV
LV WAGOterminal
363 (1800 VDC)
37
B
B
LV WAGOterminal
203 (900 VDC/1800 VAC)
1538
8015
HV
105
BMS 09.15 A / 18.15A
BMS 09.18 B / 18.18 BBMS 09.15 B / 18.15 B
BMS xx.15
122
BMS 09.15 A
BMS 09.18 A
BMS 18.15 A
BMS 18.18 A
BMS 09.15 B
BMS 09.18 B
BMS 18.15 B
BMS 18.18 B
270
327
(900
VD
C)
395
(180
0 V
DC)
97
128
97
128
97
128
400
BMS 09.18 A / 18.18A
1538
8015
400
27.5
363 (1800 VDC)
37 37
HV
LV WAGOterminal
31
1538
8015
HV
210 (900 VDC)
371 (1800 VDC)
33
LV WAGOterminal
122
122
1538
8015
HV
98
ø13.5 × 2
436812
.5
436812
.5 ø13.5 × 2
ø13.5 × 6
107144
203 (900 VDC/1800 VAC)
363 (1800 VDC)
212 (900 VDC)
373 (1800 VDC)
370
(180
0 V
DC)
97
128
123
327
(900
VD
C)
A
B
203 (900 VDC/1800 VAC)
1538
8015
HV
LV WAGOterminal
363 (1800 VDC)
37
B
B
LV WAGOterminal
203 (900 VDC/1800 VAC)
1538
8015
HV
105
BMS 09.15 A / 18.15A
BMS 09.18 B / 18.18 BBMS 09.15 B / 18.15 B
BMS xx.15
122
BMS 09.15 A
BMS 09.18 A
BMS 18.15 A
BMS 18.18 A
BMS 09.15 B
BMS 09.18 B
BMS 18.15 B
BMS 18.18 B
270
327
(900
VD
C)
395
(180
0 V
DC)
97
128
97
128
97
128
400
BMS 09.18 A / 18.18A
1538
8015
400
27.5
363 (1800 VDC)
37 37
HV
LV WAGOterminal
31
1538
8015
HV
210 (900 VDC)
371 (1800 VDC)
33
LV WAGOterminal
122
122
1538
8015
HV
98
ø13.5 × 2
436812
.5
436812
.5 ø13.5 × 2
ø13.5 × 6
107144
203 (900 VDC/1800 VAC)
363 (1800 VDC)
212 (900 VDC)
373 (1800 VDC)
370
(180
0 V
DC)
97
128
123
327
(900
VD
C)
A
B
203 (900 VDC/1800 VAC)
1538
8015
HV
LV WAGOterminal
363 (1800 VDC)
37
B
B
LV WAGOterminal
HV connections
Dimensions
[mm] BMS..15 BMS..18
58 98
360 400
A
B
Horizontal
Vertical
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.186
/// BMS09.15 / BMS18.15 & BMS09.18 / BMS18.18 (ARC CHUTE TYPE B)
1-POLE - HORIZONTAL/VERTICAL INSTALLATION
All dimensions with arc chute type A (refer to page 5) are valid for contactors equiped with arc chute type B, except for the
dimensions shown below.
370
(180
0VDC
)
212 (900VDC)373 (1800VDC) 97
327
(900
V DC)
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.18 7
DDBB
FF
AA
EECC GG BB
INSULATION DISTANCES AND WEIGHTS
The BMS contactors have been homologated according to IEC60077-2. Dimensions are indicated in the below's
representation.
Arc chute type
Insulating distances table (mm) Arc chute removal distance (mm)
Weight: ± 0.5 kgTo earthed wall To insulating wall
A B C D A B C D E F G 1 pole
BMS09.15 A 125 10 75 75 40 10 40 40 70 30 35 14
BMS18.15 A 125 10 75 75 40 10 40 40 90 20 40 15
BMS09.15 B 75 10 40 40 50 10 20 20 70 45 50 16
BMS18.15 B 75 10 40 40 50 10 20 20 80 20 80 19
BMS09.18 A 125 10 75 75 40 10 40 40 70 30 35 15
BMS18.18 A 125 10 75 75 40 10 40 40 90 20 40 16
BMS09.18 B 75 10 40 40 50 10 20 20 70 45 50 17
BMS18.18 B 75 10 40 40 50 10 20 20 80 20 80 20
/// OVERVIEW OF THE BMS..15 / BMS..18 RANGE
Arc chute Type ABMS 09.15 BMS 09.18 BMS 18.15
Arc chute Type BBMS 09.15 BMS 09.18
Arc chute Type BBMS 18.15 BMS 18.18
270
97128
122
327
97128
370
97128
122 122
Arc chute Type ABMS 09.15BMS 09.18BMS 18.15BMS 18.18
Arc chute Type BBMS 09.15BMS 09.18
Arc chute Type BBMS 18.15BMS 18.18
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.188
LOW VOLTAGE CONTROL DIAGRAM
BMS CONFIGURATION (1)
Supply voltage (2)
Un [VDC]
Control voltage (2)
UEF [VDC]
Closing power (Pc) / Holding power (Ph)
[W] / [W]Control type
Optional PCC18 (3)
Supply voltage
Un [VDC]
BMS..15, BMS..18, horizontal / vertical installation
1 pole [24-36] [24-110] ≤ 200 / ≤ 8 C24, 48, 72, 84,
110 (4)BMS..15, BMS..18, horizontal / vertical installation
1 pole [48-110] [24-110] ≤ 200 / ≤ 8 B
(1) For details refer to pages 5 & 6.(2) Control voltage UEF and supply voltage Un can be different.
(3) Horizontal installation.(4) Other voltages on demand.
AUXILIARY CONTACTS CONFIGURATION Based on the selected number of auxiliary switches, the contactor will be delivered with the switches installed as indicated in the figure and table below, and the switches status will be as shown on the electric diagram.
BM
S..1
5 /
BM
S..1
8
Auxiliary contacts
Switch position
BMS..15 / BMS..18 PCC
e f g h m n j k
1a+1b (switch PF) •
2a+2b (switch PF) • •
3a+3b (switch PF) • • •
4a+4b (switch PF) • • • •
6a+6b (switch PF) • • • • • •
Op
tio
nal
PC
C 1a+1b (switch PF) •
2a+2b (switch PF) • •
e f lhg m n p j k
B
A fe
2
13
4
g h
C
U
V
T
S kj
2
13
4 2
13
4 2
13
4
2
13
4 2
13
4
ab a b
ab ab
ab a b
l
2
13
4
n p
2
13
4 2
13
4 2
13
4
ab a b ab a b
m1st pole 2nd pole
BMS..15/BMS..18 Optional PCC
1Un+
Un-
UEF+
UEF-
B
A fe
2
13
4
g h
C
T
S kj
2
13
4 2
13
4 2
13
4
2
13
4 2
13
4
ab a b
ab ab
ab a b
n
2
13
4 2
13
4
a b ab
m
e f hg mn j k
Optional PCC
BMS..15 / BMS..18
DC
/DC
co
nver
ter
24-3
6V
DC
/DC
co
nver
ter
48-1
10V
1
2
3
4
Un+
Un-
UEF+
UEF-
5
26
3
4
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.18 9
DC
DC
+
-
C
D
Un
k1
k0
UEF
1
2
3
4
DC / DC converter
Opto-isolator
BMS closing coil
: Sécheron’s scope : Customer’s scope
: Low voltage interface : Coil controller
Un : dc power supplyU
EF : Control voltage (1)
k0 : Supply relay
k1 : Control relay
+
-
+
-
Unk1
k0
UEF
1
2
3
4
5
6
VbatP
VbatN
ORDP
ORDN
DC / DC converter
BMS closing coil
OPTIONS (SUBJECT TO ADDITIONAL COSTS)
INTEGRATED PRE-CHARGING CONTACTOR (PCC18)
Line contactors and pre-charging contactors are usually operated sequentially and mounted side by side in dedicated line breaker boxes, or directly in traction converters. Therefore, delivering an integrated unit combining both functions, line contactor type BMS and pre-charging contactor type PCC18, brings an added value to car builders, as it reduces their engineering, logistic and assembly efforts.
Control type
Control type
B
C
MAIN BENEFITSMAIN BENEFITS Optimized for the dedicated pre-charging function.
One single unit with integration of line and pre- charging contactors.
Integration on all BMS contactors installed horizontally.
Very compact solution.
Reduced overall project costs for car builders.
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.1810
On a project basis, Secheron designs and delivers complete Power Contactor Modules integrating BMS and PCC contactors, but also current measurement and other components necessary to fulfill the application.
All the components are delivered mounted on a support, with implemented high voltage connections between components, and a single low voltage interface. The Power Contactor Module is available in horizontal mounting only.
This module offers the car builder simple and easy interfaces, but also simplifies its life in terms of development, logistic and installation. Please refer to the scheme on next page.
Mounting support
LV connectorPre-charging
contactor(PCC18)
Current measurement
Line contactors BMS
POWER CONTACTOR MODULE
/// MAIN DIMENSIONS
Additional weight: + 3 kg
244
67
318309
177
61
HV
LV LV
HV
LV
HV
HV
All dimensions are in mm.
HV connections ( PCC18 ) : M6 screw.
Earth connection : through BMS.
LV connections:
- PCC18 coil : M3 screws.
- PCC18 auxiliary switches : M3 screws or faston.
/// CONTROL DIAGRAM
BM
S
PC
C18
LV
BMS 1-pole + PCC18
For the control diagram, please contact Sécheron as it depends of the chosen configuration.
The drawings here above represent the PCC18 when mounted on any horizontal BMS..15 and BMS..18 versions. The other dimensions of the BMS..15 and BMS..18 indicated on page 5 and 6 remain valid.
POWER CONTACTORS, BMS09.15 / BMS18.15 AND BMS09.18 / BMS18.18 11
BMS..15/BMS..18 rangeApplication: - Rolling stock (Line/separation contactors, ...).- Fixed installation (depot feeder contactor...).
HS typeApplication: - Rolling stock (Pre-charging, Heating, HVAC, .....).- Fixed installation (Line testing, ...).
BMS15.002 typeApplication: - Rolling stock (Pre-charging, Heating, HVAC, .....).- Fixed installation (Line testing, ...).
BMS30.15C typeApplication: - Rolling stock (Line/separation contactors, ...).- Fixed installation (depot feeder contactor...).
SEC rangeApplication: - Rolling stock (Line/separation contactors, PM motor,...).- Fixed installation (depot feeder contactor, ...).
BMS..08/BMS..10 rangeApplication: - Rolling stock (Line/separation contactors, ...).- Fixed installation (depot feeder contactor...).
SECHERON CONTACTORS RANGE
180015001000 13008005020
900
1800
3600
I [A]
U [V= / V~]
HS
bB
MS
15.0
02
BMS18.18
BMS09.18
BMS18.08
BMS09.08
SEC18.13
SEC40.10 SEC36.13
SEC09.13
BMS18.15
BMS30.15C
BMS09.15
SEC20.10
BMS18
.10
SEC10.10
BMS09
.10
180015001000 13008005020
900
1800
3600
I [A]
U [V= / V~]H
Sb
BM
S15
.002
BMS18.18
BMS09.18
BMS18.08
BMS09.08
SEC18.13
SEC40.10 SEC36.13
SEC09.13
BMS18.15
BMS30.15C
BMS09.15
SEC20.10
BMS18
.10
SEC10.10
BMS09
.10
BMS09.081 poleArc chute Type A
BMS18.081 poleArc chute Type A
BMS09.082 polesArc chute Type A
BMS18.10 1 poleArc chute Type A
BMS09.151 poleArc chute Type A
BMS18.181 poleArc chute Type A
SEC10.10 /SEC09.13
SEC20.10 /SEC18.13
SEC40.10 /SEC36.13
BMS15.002 HSB
Copyright© 2017 Sécheron SA
This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser’s responsibility to inform himself, no matter what the circumstances, of the product’s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our “General Delivery Conditions”.
SG
20
24
54
BE
N_A
05
-10
.17Sécheron SA
Rue du Pré-Bouvier 251242 Satigny - GenevaCH-Switzerland
Tel: +41 22 739 41 11Fax: +41 22 739 48 [email protected]
Place and date: Name: Signature:
DESIGNATION CODE FOR ORDERING• Be sure to establish the designation code from the latest version of our brochure by downloading it from the website: www.secheron.com• Be careful to write down the complete alphanumerical designation code with 17 characters when placing your order• For technical reasons some variants and options indicated in the designation code might not be combined• For other configurations not described in the brochure, please contact Sécheron
The bold characters of the designation code define the device type.
DESIGNATION CODE
Note: some combinations may not be possible, therefore validate your configuration with Sécheron before ordering
Example of customer’s choice: BMS 18 18 A 1 Z C E A 1 H D ALine: 10 11 12 13 14 15 16 17 18 19 20 21 22
Line Description Designation Standard Options Customer’s choice
10 Product type BMS BMS BMS11 Rated operational voltage 900 VDC / 1800 VAC 09 1800 VDC 1812 Rated conventional free air thermal current (1) 1500 A 15 1800 A 1813 Arc chute type Type A A Type B B 14 Number of pole 1-pole 1 115 Poles mechanical synchronization Not applicable Z Z16 Integration of Pre-Charging Contactor PCC18 No 0 Yes C17 Control voltage (2) 24 Vdc a 36 Vdc B 48 Vdc C 72 Vdc D 84 Vdc H 96 Vdc 4 110 Vdc E 18 Auxiliary contacts BMS 1a + 1b - (switch PF) - silver type A 1a + 1b - (switch PF) - gold type C 2a + 2b - (switch PF) - silver type E 2a + 2b - (switch PF) - gold type H 3a + 3b - (switch PF) - silver type K 3a + 3b - (switch PF) - gold type M 4a + 4b - (switch PF) - silver type O 4a + 4b - (switch PF) - gold type P 6a + 6b - (switch PF) - silver type U 6a + 6b - (switch PF) - gold type X19 Auxiliary contacts (PCC18) (No PCC18) Not applicable Z 1a + 1b - (switch PF) - silver type 1 1a + 1b - (switch PF) - gold type 2 2a + 2b - (switch PF) - silver type 3 2a + 2b - (switch PF) - gold type 4
20 Installation Horizontal & Vertical (3) V V
21 Application type (Direct Current) DC D (Alternating Current) AC A
22 Opening BMS arc chute Arc chute lever A A
(1) For DC and AC voltage up to 60 Hz frequency. For higher frequency, please contact Sécheron • (2) Control coil of PCC18 is delivered with a surge arrester.(3) PCC18 is valid for horizontal mounting only.