high performance post singulation test...1d/2dmc code reader 2d/3dflex ball/bump co-planarity mark,...

2
High Performance Post Singulation Test Full Traceability with MAP file update 100% touch down efficiency Side walls µcrack inspection with minimum crack thickness down to 5µm Precision Eliminates test escapes created by singulation process Tri Temp testing Direct docking to test head Full test & finishing process in one system Stress-Free Handling No clamping mechanism Device alignment by vision (closed-loop) 6 sides vision inspection Full traceability Productivity & Flexibility High test parallelism with 100% touch down efficiency Kitless AccuChuck can accommodate various device patterns for reuse of existing probe cards / sockets High throughput for high volume manufacturing and high-volume QA

Upload: others

Post on 21-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: High Performance Post Singulation Test...1D/2DMC code reader 2D/3DFlex ball/Bump co-planarity Mark, Surface, Top, Bottom, 4 sides Pre-tape, In-tape, post sealing inspection Testing

High Performance Post Singulation Test

Full Traceability with MAP

file update

100% touch down

efficiency

Side walls µcrack inspection with minimum crack

thickness down to 5µm

Precision � Eliminates test escapes created by singulation

process

� Tri Temp testing

� Direct docking to test head

� Full test & finishing process in one system

Stress-Free Handling � No clamping mechanism

� Device alignment by vision (closed-loop)

� 6 sides vision inspection

� Full traceability

Productivity & Flexibi l ity � High test parallelism with 100% touch down

efficiency

� Kitless AccuChuck can accommodate various device patterns for reuse of existing probe cards / sockets

� High throughput for high volume manufacturing and high-volume QA

Page 2: High Performance Post Singulation Test...1D/2DMC code reader 2D/3DFlex ball/Bump co-planarity Mark, Surface, Top, Bottom, 4 sides Pre-tape, In-tape, post sealing inspection Testing

High Performance Post Singulation Test

Rev2019042

4

[email protected]

Test Handler Group

Cohu, Inc.

12367 Crosthwaite Circle, Poway, CA 92064-6817 | Tel. +1 858.848.8000

www.cohu.com | © 2019 Cohu, Inc.: All rights reserved.

Process Capabilities

Input Wafer frame, De-taping Waffle Pack

Output Tape & Reel Output Sorting

Jedec Tray Waffle Pack Wafer frame

Processes Device Flip X-Y- θ touchless precisor Kitless AccuChuck Direct docking to tester head Tri-temperature testing Laser marking (optional) 6 sides vision inspection Multiple sorting in Waffle Pack or single wafer frame Tape & Reel (max. 2) Automatic rejection & replacement in tape NVcore Vision Inspection

1D/2DMC code reader 2D/3DFlex ball/Bump co-planarity Mark, Surface, Top, Bottom, 4 sides Pre-tape, In-tape, post sealing inspection

Testing High test parallelism with 100% touch down efficiency Tri-temperature testing Automatic probe card cleaning Device placement accuracy within ±15µm

Specifications

Performance Characteristics Process UPH up to 16,000UPH with Wafer input Process UPH up to 12,000UPH with de-taping input MTBA: Typical ≥ 1h MTBF: Typical ≥ 168h

Temperature Characteristics Range: ambient to 135° Range: -45°C to 160° (under development) Accuracy: ±2°C Soak capacity: 6 AccuChuck (max.) Time to temperature: ≤30min 1

ESD Control Field strength at device < 100 Volt/inch (max) Decay time: 1,000V to 100V in ≤10 s Ionizer Balance: ±30V. (Class 1 ±5V optional)

Electrical Interfaces TTL parallel interface for Tester and Laser RS232, GPIB (optional) Network: Ethernet capability Wafer Mapping: SECS GEM (SEMI E4, E5, E30, E37)

Wafer Input Media Wafer frame: 4” to 12” wafer De-taping: 8, 12, 16, 24mm

Output Tape & Reel (max. 2) : 8, 12, 16, 24mm Waffle Pack: 2”x 2” (max. 32), 4”x 4” (max. 9) Wafer frame (max. 1): 4” to 12” wafer Jedec Tray: 2 (max.)

Device range WLCSP: 1 x 1 to 12 x 12mm / thickness ≥ 100μm

AccuChuck Dimensions Overall dimension: 55 x 175mn Maximum working area: 50 x170 mm Devices per AccuChuck: 600 (max.)

Facilities Requirement

I/O Modules: 100VAC - 240VAC 50/60 Hz, One Phase 3.5kVA with vacuum pump (optional) Test Module: 208 VAC - 240VAC 50/60 Hz, Three Phases 9.6kVA with vacuum pump (optional)

Common Air Pressure range: 6 to 10 bar ± 10% Air consumption: 500l/min (typical) Vacuum Network: 0.6 Bars ± 10% CDA dew point: < -70°C; Air temp range +15°C to +40°C

Physical Dimensions Overall dimensions: 3 x 2.5 x 2.1m Weight net: 1900 to 2400 kg (configuration dependent)

Specifications subject to change without notice.

For detailed performance specifications, please contact Cohu. 1Ambient (+25°C) to set point