high module efficiency, up to 15.40% positive tolerance for

2
KV250-60P 250Wp KV245-60P 245Wp KV240-60P 240Wp KV235-60P 235Wp KV230-60P 230Wp KV225-60P 225Wp KV220-60P 220Wp 12 years product warranty for materials and workmanship 25 years output warranty, 12 years>= 90%, 25years >=80% Worldwide Product Liability Insurance covered by Zurich Insurance Local warehousing 48 hour-response service Enhanced design for easy installation and long term reliability Customized production, e.g. black module, special frame, BIPV Punctual and safe delivery, reliable supply to keep project schedule Vertically integrated production including ingot, wafer, cell and module High module efficiency, up to 15.40% Positive tolerance for mainstream products, 0 ~ +5W Tested for 5400Pa load capacity, suitable for heavy snow areas Anodized aluminum frame to improve corrosion resistance High transparent, low iron tempered glass to improve module efficiency Encapsulated junction box,better insulation, sealing, heat dissipation Module with Anti-reflection glass for special application e.g. highways 25 years Product Performance Insurance covered by MunichRE Special module for low light or cloudy environment Local technical support Polycrystalline

Upload: others

Post on 12-Sep-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: High module efficiency, up to 15.40% Positive tolerance for

KV250-60P 250WpKV245-60P 245WpKV240-60P 240WpKV235-60P 235WpKV230-60P 230WpKV225-60P 225WpKV220-60P 220Wp

12 years product warranty for materials and workmanship 25 years output warranty,12 years>= 90%, 25years >=80%

Worldwide Product Liability Insurancecovered by Zurich Insurance

Local warehousing

48 hour-response service

Enhanced design for easy installationand long term reliability

Customized production,e.g. black module, special frame, BIPV

Punctual and safe delivery,reliable supply to keep project schedule

Vertically integrated production including ingot,wafer, cell and module

High module efficiency, up to 15.40%

Positive tolerance for mainstream products, 0 ~ +5W

Tested for 5400Pa load capacity,suitable for heavy snow areas

Anodized aluminum frame to improvecorrosion resistance

High transparent, low iron tempered glass toimprove module efficiency

Encapsulated junction box,better insulation, sealing, heat dissipation

Module with Anti-reflection glass for specialapplication e.g. highways

25 years Product Performance Insurancecovered by MunichRE

Special module for low light or cloudy environment

Local technical support

Polycrystalline

Page 2: High module efficiency, up to 15.40% Positive tolerance for

Electrical Data

Model TypePeak Power [Pmax]Cell EfficiencyModule EfficiencyMaximum Power Voltage [Vmp]Maximum Power Current [Imp]Open Circuit Voltage [Voc]Short Circuit Current [Isc]Power Tolerance

Maximum System VoltageNormal Operating Cell TemperatureSeries Fuse Rating [A]Number of Bypass DiodesVoltage temperature coefficientsCurrent temperature coefficients

Power temperature coefficients

Mechanical Data

Working ConditionsMaximum surfaceload capacity

Hail

Temperature range – 40 °C to + 85 ℃

maximum diameter of 25 mmwith impact speed of 23 m/s

tested up to 5,400 Pa accordingto IEC 61215 (advanced test)

Temperature dependence of Isc,Voc and Pmax

Electrical performance(cell temperature:25℃)

Irradiance dependence of Isc,Voc and Pmax (cell temperature:25℃)

ELECTRICAL CHARACTERISTICS

Cell Temperature (℃) Irradiance (W/m2) Voltage [V]

The electrical data relates to standard test conditions [STC]: 1,000 W/m²; AM 1.5; 25 °C. Performance deviation of Pmpp: -/+ 3%. performance deviation of Voc[V],Isc[A],Vmpp [V] and Impp [A]: -/+ 10%.

The parameters are for reference only, and are subject to change without notice or obligation.Please contact [email protected] for quotation, and [email protected] for technical support.

*

Cell Type No. of Cells

Dimensions

Weight

60 (6×10)

Poly 156mm×156mm

1640×990×45mm (L×W×H)1640×990×50mm (L×W×H)

19.5kg(45)/ 20.5kg(50)cable(-) cable(+)

Junction box

Cur

rent

(A)

Voc

ISCPmax

0 200 400 600 800 1000

100

80

60

40

20

0

Nor

mal

ize

Isc,

Voc

and

Pm

ax(%

)

120

100

80

60

40

20

0

-25 0 25 50 75 100

ISC

Voc

Pmax

Nor

mal

ize

Isc,

Voc

and

Pm

ax(%

)

Temp.Coeff.of Isc =+0.065%/℃Temp.Coeff.of Voc =-0.346%/℃Temp.Coeff.of Pmax=-0.46%/℃

Pow

er(W

)

0 5 10 15 20 25 30 35 400

2

4

6

8

10

230.2 W

183.3 W

136.1 W

88.7 W

41.7 W

250

200

150

100

50

0

1000V

45℃±2℃

15

3-0.346 %/℃

0.065 %/℃

-0.46 %/℃

KV250-60P

250W17.47%

15.40%30.2V

8.30A37.1V

9.02A

KV245-60P

245W17.12%

15.09%30.0V

8.18A37V

8.90A

KV240-60P

240W16.77%

14.78%29.8V

8.06A36.9V

8.78A

KV235-60P

235W16.42%

14.47%29.6V

7.94A36.8V

8.66V

0~+5W0~+5W0~+5W0~+5W

KV225-60P

225W15.72%

13.86%29.2V

7.71A36.6V

8.46A

0~+5W

KV230-60P

230W16.07%

14.17%29.4V

7.83A36.7V

8.54A

0~+5W

KV220-60P

220W15.37%

13.55%29V

7.59A36.4V

8.32A

0~+5W