Heat Exchanger Tubing Inspection:

Revolutionizing Asset Integrity Management

Mor

e in

fo a

bout

this

art

icle

: ht

tp://

ww

w.n

dt.n

et/?

id=

2234

9

Page 2: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

SPEAKER PRESENTATIONRudolph Nel

Eddyfi Technologies

General Manager - Africa

• General Manager for Eddyfi, Silverwing, TSC and Teletest products lines in Africa

• Over 20 years of experience in the NDT industry

• Eddyfi Technologies offices are located in Cape Town, South Africa

2

Page 3: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

CONTENT1. Heat exchangers

2. Conventional tubing probes

3. Why move to an array technology?

4. Manual pulling

5. Why move to a probe pusher?

6. Manual analyst

7. Why move to the automatic data screening?

8. Innovating to combine the best of both worlds

3

Page 4: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

HEAT EXCHANGERS• Mainly used in Oil & Gas industry, to transfer heat between fluids

• Some use cold water or large fans to dissipate the heat

• Designed with straight tubes or U-bends

• Made of ferrous and non-ferrous material

4Conventional heat exchanger Fin fan air cooler heat exchanger

Page 5: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

CONVENTIONAL TUBING PROBES• ECT for the non-ferromagnetic and the RFT & NFT for the ferrous tubes inspection

• Fast acquisition, good detection and sizing capabilities (NFT = screening tool)

• Typical flaws (pitting, fretting, erosion, general corrosion)

• Most of the time re-scanned by IRIS

• Very limited on crack detection, crucial information for the plant owner

• Strip chart analysis only – no C-scan imaging

5

Eddy current density simulation performed with COMSOL® Multiphysics with ECT ECT Typical strip chart display

Page 6: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVING TO AN ARRAY TECHNOLOGY?• Uses individuals multiplexing coils to

“sweep” the entire interior surface

• Makes circumferential flaws easier to identify (length and position)

• Easily displayed by C-scan imaging

• Better defect discrimination at support plate and at tubesheet

6 Circ. crack located under support

Page 7: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO AN ARRAY TECHNOLOGY?• ASME calibration tube with additional axial & circ. cracks simulator with ECA

7

Circ. 3D view

Axial 3D view

C-scan

ASME machined defect

EDM Axial cracks

EDM Circ. cracks

Page 8: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO AN ARRAY TECHNOLOGY?• Significant circumferential cracking detected with an ECA probe and then confirmed by borescope and X-ray.

8

3D viewC-scan

Borescope picture X-Ray measurement

Page 9: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO AN ARRAY TECHNOLOGY?• 28 years-old fin fan air cooler tube inspected with Near Field array technology (NFA)

9

NFA C-scanStrip chart IRIS C-scan

NFA 3D view

Cluster pits

Erosion with pits

Taper erosion at tubesheet

NFA called 35% pits wall loss

Re-scanned by IRIS

and confirmed 35%

pits wall loss

Page 10: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO AN ARRAY TECHNOLOGY?• NFA can both detect and differentiate a located pit and a circumferential crack

10

3D view

C-scan Impedance plane

Circ. crack

Isolated pit

Pit signal signature

Circ. crack signal signature

Page 11: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

MANUAL PULLING• Hand-pulling is widely used in the industry

• This technique is easy to deploy with reasonable cost

• However, it remains:• Less repeatable • Time consuming• Higher risk of error• Human factor not controlled – worker fatigue • No encoded data – with limited sizing capabilities

11

Page 12: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO A PROBE-PUSHER?• What the probe pusher values are?

• Efficiency – saving time / money• Encoded data• Higher precision & accurate data• Higher sizing capabilities• Controls human factor• Allows historic / correlated data• Accuracy on the bundle life cycle

• Some work needs to be done to convince the service providers and asset owners to integrate a probe pusher in the industry

• Cost / ROI

12 Remote Field inspection using the Probot

Page 13: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

MANUAL ANALYSIS• Inspection crews are normally composed of :

• 1 probe hand-pulling operator• 1 acquisition PC operator• 1 data analyst / crew supervisor

• Depending on the site requirements or the crew structure:• 1 analyst can be used for several acquisition crews• Also good analysts are rare in the industry• Sometimes, they can work on day and night shifts !• Where they cannot keep the pace – analysis delay!

• Final report can be released several weeks after the last pulled tube

• Experts charge extra hours to reduce that gap – who will pay for that?

• The asset owner has to wait or to take critical decision based on partial information

Page 14: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO THE AUTO DATA SCREENING? • Auto data screening requires additional setup time

compared to manual analysis (setting detection thresholds, etc.)

• Manual analysis takes on average about 30 sec/tube for experienced data analyst

• Using the auto screening, it will take about 1 sec/tubeand all files will automatically be tagged as “NDD” or “to review”

• This way, the analyst will concentrate his efforts on the tagged files to review

• Doing so,• The analyst time will be drastically reduced• Optimization of the “re-scan” tube list• Faster generation of final report • Number of analysts required for the same job

is significantly reduced14

Page 15: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

WHY MOVE TO THE AUTO DATA SCREENING?

15

Page 16: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

INNOVATING TO COMBINE THE BEST OF BOTH WORLDS Array technology• Increases the quality data (c-scan imaging)

• Increases the productivity

• Increases the sizing capabilities

Acquisition with Probe Pusher• Efficiency, higher productivity / saving time and money (Controls the human factor)

• Encoded data, higher precision / accurate data

• Moreover, it allows data history by correlating the data, year after year

16

Page 17: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

INNOVATING TO COMBINE THE BEST OF BOTH WORLDS Auto data screening• Drastically reduces analyst time

• Optimizes the re-scan tube list

• Faster final report generation

• Reduces the number of analysts required for the same job

This solution optimizes the acquisition and analyst time, with the highest possible data resolution and defect position, monitored through time to yield optimal asset integrity management!

17

Page 18: Heat Exchanger Tubing Inspection: Revolutionizing Asset Integrity … · 2018. 3. 27. · Conventional heat exchanger Fin fan air cooler heat exchanger. CONVENTIONAL TUBING PROBES

Thank you!