hammar lifebuoy release system · 2011-03 hammar lifebuoy release system installation manual...
TRANSCRIPT
2011
-03
HAMMAR LIFEBUOY RELEASE SYSTEMINSTALLATION MANUAL
Specification:• OneGRPholderwithpre-installedmetalholderandbracket.• OneERU(electricremoteunit)withcordpre-installedonmetalholder.• OneReleaseSwitch• OneConnectorbox• 20mcablefromconnectorboxtoreleaseswitch,screened2x0,75mm2,diameter8mm• Onemanualsafetypin• Onepilotlineforloadingthelifebuoy• Oneinstallationmanual• OneUserGuide• OnemarkinginstructionNot supplied in the kit from CM Hammar:•Lifebuoy•Mountingboltsfortheinstallationonboard
Installation:1. MounttheGRPholderinapositionsothatareleasedlifebuoywilleasilyfallintothewater.
2. Followtheinstructionsforthemountingboltsinaccordancewiththepictures.MakesurethatyoumountdoublewashersbetweenframeorbulkheadandtheGRPholder.
2011
-03
3. MounttheconnectorboxclosetotheGRPholder.MakesurethatthecablefromtheERUislongenoughtoreachtheconnectorbox.
4. InstallthescreenedcablefromtheconnectorboxtotheReleaseSwitchandconnecttheblackERUcabletotheconnectorbox.
5. MounttheReleaseSwitchinaneasytolocateandmanageposi-tionon thebridge.TheReleaseSwitchshallalwaysbemountedinsidethewheelhouseorbridge.
6. Connect24VemergencypowersupplytotheReleaseSwitch.Ensurethatyoufollowtheenclosedcon-nectiondrawing.Testtheelectricalinstallationaccordingtoinstructionsonthedrawing.
7. TheERUispre-installed.TheERUmustbemarkedwithitsexpirydate2yearsfrominstallationonboard.Followtheenclosedmarkinginstruction.AnERU,whichisnotproperlymarkedwithitsdateofexpiry,isnotapproved.
8. Putalifebuoy2/3rdsintotheGRPholderandthensecureitfortheinstallationphase.Usethesupp-liedthinwhitepilotlinetopullthereleasecordthroughtheERUunit.Makesurethatthelifebuoylineisnotontheoutwardsideofthereleasecord!Thismightentanglethelifebuoyinanactivationsituation.
2011
-03
9. PullupthereleasecordthroughtheERUholewiththepilotline.Secureitwiththemanualsafetypin.
10.ConnectthepowertotheReleaseSwitch.
11.ThesafetycoverontheReleaseSwitchcanbesecuredwithsomekindofeasy-to-breakseal,inordertoavoidunintentionaluseofthesystem.
12.Thesystemisnowreadyforuse.TheERUshallbechangedaftertwoyearsofservice.
2011
-03
190780
958
510650
60
800
16060
67068
054
0
M8(x5)
GRP HOLDER DRAWING
Sideview Backview Frontview Topview
2011
-03
CONNECTOR BOX DRAWING55
55 38 45
45 4,30
Front side Back
tor.ctor.c
1
CM HAMMAR ABTel.: +46 31 709 65 50 Fax.: +46 31 49 70 23
Drawn/Ritad Checked/Kontr. Appr./Godkänd Scale/skala Repl./Ersätter: Date/Datum: (dd-mm-yyyy)
Draw.No./Ritn.nr.
Det. Number/ant. Designation/benämn.
Sheet1
Notes/noteringarMaterial
tor.c 10-07-2009
A010007-01
1:1
CONNECTOR BOX ERU
Rev.: 1of
2011
-03
RELEASE SWITCH DRAWING
7
87
87
tor.ctor.c
1
CM HAM
MAR AB
Drawn/Ritad
Checked/Kontr.
Appr./G
odkändDate/Datum
:Repl./Ersätter:
Scale/skalaDraw
.No./Ritn.nr.
Det.Num
ber/ant.Designation/benäm
n.M
aterialNotes/noteringar
RELEASE SWITC
H - DIMENSIO
NS
Sheet1
A010031
tor.c10-07-2009
1:1
Tel.: +46 31 709 65 50 Fax.: +46 31 49 70 23
Rev.:1of
82
MA
XIMUM
DIA
METER FO
R CA
BLE 12 mm
102
102
2011
-03
WIRING CONNECTION DIAGRAM ERU
1
2
3
4
5Note 1
12
34
56
Terminals
+24VDC
0VDC+ERU outp.
- ERU outp.(- ERRS)
(+ ERRS)
Optional connection to ERRS System
, Terminal No:
2 to + output ERRS System (upper term
inals 1-10 in ERRS control box)5 to - output ERRS system
(Lower term
inals 1-10 in ERRS control box)
POW
ER SUPPLY, Terminal No:
1 to +24VDC
EMERG
ENCY PO
WER SYSTEM
4 to 0VDC
EMERG
ENCY PO
WER SYSTEM
TESTING THE INSTALLATIO
N:The correct function of the HAM
MAR ERU RELEASE SW
ITCH can be tested by
connecting a 200 mAF 5x20 m
m glass tube fuse to the ERU RELEASE SW
ITCH
output instead of the pos. 1 ERU unit. The fuse blows off w
hen the ERU RELEASE SW
ITCH push button is pressed if the system
is correctly installed.
CM HAM
MAR AB
Drawn/Ritad
Checked/Kontr.
Appr./Godkänd
Date/Datum: (dd-m
m-yyyy)
Repl./Ersätter:Scale/skala
Draw.No./Ritn.nr.
Det.Num
ber/ant.Designation/benäm
n.M
aterialNotes/noteringar
Tel.: +46 31 709 65 50 Fax.: +46 31 49 70 23
HAMM
AR H20 ERU - RELEASE SWITC
H 24VDC
- CO
NNECTIO
N DIAGRAM
ERU1001
tc03-10-2007
Rev.:5
tctc
Sheet11
of
POS 1: HAM
MAR ELEC
TRIC RELEASE UNIT (ERU), operating voltage 10 - 15VD
C, 3A
POS 2: HAM
MAR ERU C
ONNEC
TION BO
XPO
S 3: HAMM
AR ERU RELEASE SWITC
H 24VDC
Input voltage 18VDC
- 32VDC
Max. interm
ittent load 3APO
S 4: Cable, 2 x 0,75 m
m2 (screened). O
uter diameter 5-10 m
m.
POS 5: C
able, 4 x 0,75 mm
2 (screened). Outer diam
eter 5-12 mm
or C
able, 2 x 0,75 mm
2 (screened). Outer diam
eter 5-12 mm
.
Note 1: When connecting the cable from
the H20 -ERU to the CO
NNECTIO
N BOX,
the polarity of the wires is of no im
portance.