ha3021 all-in-one proximity stand alone controller

15
HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.25.2011 All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60 HEART ENTERPRISE CO. LTD.

Upload: others

Post on 24-Dec-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20110

All- IN- ONE PROXIMTYSTAND ALONE CONTROLLER

OPERATION MANUALMODEL: HA3021VERSION: 3.60

HEART ENTERPRISE CO. LTD.

Page 2: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20111

Table of Contents

Features 2

Specification 3

Wiring Description 4

Installation 5

1.Wiring Diagram of HA3021(Security controller included) 5

2.Wiring Diagram of HA3021 6

Main Function Description 7

1.Basic operation 7

2.Card Management 7

3.Duress Function 7

4.Guard Function 7

5.Modify Personal password 7

6.Back-up password 8

Parameter Listing 9

Parameter setting 10

Display / Error/ Warning message 11

Factory Default List 14

Page 3: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20112

FEATURES1. Proximity type reader, read range up to 10cm (4’’).2. Proximity card are less prone to physical damage or loss.3. Memory capacity store up to 5000 card holders.4. LCD display ,16 characters×2 lines with back light

5. Three access mode options:(1). Mode 0: Card only (default).(2). Mode 1: Card and PIN..(3). Mode 2: Card only or main password.

6. Anti-duress function : Card + personal password + random number or mainpassword + random numberWith the anti-duress function provided, you no longer kidnap by thief. Key in a preset code tothe rear, the duress relay will be activated to the require alarm device, other than the dooropened normally.

7. Guard function : Guard password + CardThe function can be used to arm/disarm the connected security system.

8. Personal Identification Number (PIN)Each card can be added with a four-digit PIN. This PIN is only valid when “Mode 1: Card andPIN of the access modes are selected, which provides higher security.

9. Lock out on invalid passwordTo prevent unauthorized persons from gaining password entry by trial and error, the systemactivates an alarm relay and/or automatically deletes the card number after five tries, once theoption id selected in the system.

10. Keypad pause functionKeypad key in incorrect five times and no distance of 1min, keypad function will stop1min and display

READY FOR CARDENTRY HALT

11. User card can be register /delete in batch mode12. Large 2-line LCD of 16 characters with back light feature including power saver

function: the back light will turn off if inactive for more than 3 minutes..13. Alarm to be activated once incorrect password key-in five times within four minutes.14. Last 100 Access Granted card numbers can be viewed on-screen.15. Strike, alarm and duress relay have selectable activation timer (00-255 seconds)16. Selectable door left open timer(0-255 seconds)17. Audible key tone available18. For safety reason the * will be displayed when entering card number or PIN19. Force entry alarm function available.20. Tamper alarm function available.21. Three-piece enclosure design the reader is patted for weather and hazard proofing22. A separate relay module design, high security provided23. Check the record in any time.24. Open door to key-in Card number.25. Build-in RS485, copy data by this controller parameter and enrolled card.

Page 4: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20113

SPECIFICATION

Input Voltage : DC +10V to 15V

DC Current : Average 135mA @12VDC; Peak 300mA @12VDC

K1(Strike) & K2(Alarm) 0.4A @125VAC / 2A @30VDCContact Current : K3(Bell) & K4(Guard) 0.1A @100VAC / 0.5A @20VDC

Frequency (optional) : 125KHz、134.2KHz or 13.56MHz

Read Range : 1. 125KHz & 134.2KHz:Up to 7 ㎝ (In noise-free

environment)

2. 13.56MHz:Up to 5 ㎝ (In noise-free environment) *1

Keypad : 12 keys (0 ~ 9,*,#)

Display : 16 characters, 2 lines, LCD with backlight.

LED Indicator : Bicolor (Greed/Red)

Memory Capacity : 5000 cards (Including PIN) & last 100 transactions

Weight : 380g MAX

Operating humidity : 5%~95% (relative humidity, non-condensing)

Operating temperature : 0 ~70℃ ℃ / 32℉~158℉

Card type (optional) : EM、HID、Mifare(ISO14443A)、TI-LF(134.2KHz) or

TI-HF(ISO15693)Case material : ABS (UL94V0)

Dimensions : 150 x 110 x 45 mm / 5.9 x 4.3 x 1.8 in.

Remark: *1. Reduced read range with keytag and proximity sticker.

WIRING DESCRIPTION

Pin Wire Colore Function Description

1 Red V+ + 8.5V to 16V DC

2 Black GND Power Ground

3 Blown EXIT Exit Button

4 Orange STATUS Door Status Sensor

5 Yellow COM1 Strike Relay COM

6 Green NC/NO1 Strike Relay NC/NO

Strike Relay

Contact Selection

7 Blue COMS Alarm Relay COM

8 Purple NC/NO2 Alarm Relay NC/NO

Alarm Relay

Contact selection

Page 5: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20114

9 Grey COM3 Door Bell Relay COM

10 White NO3 Door Bell Relay NO

11 Light Blue COM4 Guard Relay COM

12 Light Green NO4 Guard Relay NO

13 Deep Pink Guard+ Guard Status Sensor(+)

14 Light Pink Guard- Guard Status Sensor(-)

Page 6: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20115

INSTALLATION

1. Wiring diagram of HA3021(Security controller included).

Page 7: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20116

2.HA3021 Wiring Diagram

Page 8: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20117

MAIN FUNCTION DESCRIPTION1. Basic operation

MODE 0 – Card only – DEFAULT: This mode only requires the userto present his card to be granted access.

MODE 1 – Card and PIN: The mode requires that the user presentshis card and then enters his PIN on the keypad. This mode is suitablefor application s where higher security is needed.

MODE 2 – Card only or main password only: This mode will requirethat the user presents his card to the reader or enter main passwordusing the keypad to be granted access.

Open the door by exit button: Opening the door just pressed the exit button.

2. Card ManagementUp to 5,000 user cards can be registered in the HA3021 system. All cardsare required to be registered in the system before use. Depending on howmany cars you need to program, you can simply add them one at a time oruse the batch process to ass a per-selected batch of cards in the system.For more information on cards, refer to the “Adding & Deleting Cards”section.

3. Duress Function:The duress function is used to provide added security to personnel. Insituations of duress, a cardholder presents his card to the reader, andthen enters his PIN + any one-digit number (0-9) when the MODE1 ofthe access modes is selected. Or enter the master password + anyone-digit number (0-9) when the MODE 2 of the access modes isselected.

Access Mode Duress operation procedures1 MODE 0 – Card only Not available2 MODE 1 – Card and PIN Card + PIN + (any one-digit number)+#3 MODE 2 – Card only or main

password onlyEnter master password + (any one-digitnumber) +#

4. Guard Function: (Guard password + # + Card)HA3021 equipped a guard relay which can arm or disarm the connectedsecurity system. Use guard password or guard pass word plus card data toactivate this function.

Page 9: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20118

5. Modify Personal password:1. MODE 1, display after sensor card

Enter PasswordCode NO.:

2. And now enter * + old personal password (default: 0000)

New PasswordCode NO.:

3. Enter new password(4 digit) and enter # .

6. Back- up password:Back up password: 23400204Key-in back up password and enter # when forgot the password, and thensensor the valid card, you will enter the setting mode. And settingpassword recover 111111(factory default), controller have to at least enrollone valid card.Operation: Key-in back-up password (23400204) + # + Valid Card.

Page 10: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.20119

PARAMETER LISTINGThe hierarchy diagram shows the relationship of each function

Main function Function 1 Function 2 Function 3 Function 4 Function 5 Function 6

1.ENROL 1.S-ADD2.S-DEL3.B-ADD4.B-DEL

2.PASSWD 1.MASTER2.MAIN3.REVIVE4.GUARD

3.TIMER 1.STRIKE2.ALARM3.DB4.GUARD1.ALARM 1.FORCE

2.TAMPER3.P-ERR

4.DURESS2.KNOCK3.GUARD 1FUNCTION

2.GUARDCIRCUIT1.ReALARM2.CARD3.RECORD

4.SYSTEM 1.REVIVE2.TONE3.ACCMOD

1.DOOR2.ERASE 1.MEMORY

ERASE2.RECORDERASE

3.CLOCK1.DatabassCopy

1.PARAMTER2.ENROLLEDCARD

4.OTHER

4.MORE

4.MORE

4.MORE2.HardwareTest

Page 11: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.201110

PARAMETER SETTING1. Enrollment

Entry the parameter setting, press “# “ for three seconds and when monitor changeenter “ 1 “, then enter the default master code "111111" (factory default).

1.1 Add a new card(S_ADD) : 1→1→Card or password → # 1.2 Delete a card(S_DEL) : 1→2→ Card or password→ # 1.3 Add the cards in batch mode(B_ADD) : 1→3- Card serial no.1→ enroll card

quantity you want (1~5000). → # 1.4 Delete the cards in batch mode(B_DEL) : 1→4 → Card serial no.1 → delete

quantity of card (1~5000).→ # 1.5 Modify setting password(MASTER) : 2 →1 → random 6 digit number→ # 1.6 Modify main password(MAIN) : 1→1 random 4 digit number→ # 1.7 Modify relieve arm password(REVIVE) : 2→3 → random 7digit number→ # 1.8 Modify guard password(GUARD) : 2-→ 4 → random 3 digit→ # 1.9 Modify strike active time (STRIKE) : 3→1→ 0~255 sec.(0 sec. is LATCH mode) → # 1.10 Modify alarm active time(ALARM) : 3→2→0~255 sec. (0 sec. is last alarm) → # 1.11 Modify an interval time of door left open(DB) : 3 → 3→0~255 sec. (0 sec. ***)→#- 1.12 Modify security relay motion time(GUARD) : 3→4→0~255 sec. (0 sec. is LATCH

mode)1.13 Force entry setting enable/disable(FORCE) : 4→1→1→1(DISABLE-ENABLE) →# 1.14 Tamper alarm setting(TAMPER) : 4→1→2→1(DISABLE- ENABLE) →# 1.15 Alarm activated when enter incorrect password five times(P_ERR) :

4→1→3→1(DISABLE-ENABLE) →# 1.16 Anti-duress alarm(DURESS) : 4-1-4-1(DISABLE-ENABLE) →# 1.17 Door bell function(KNOCK) : 4→2→1(DISABLE- ENABLE) →# 1.18 Guard setting function(GUARD FUNCTION) : 4→3→1→1(DISABLE-ENABLE) →# 1.19 Guard circuit status detection(GUARD CIRCUIT) : 4→3→2→1(DISABLE-ENABLE) →# 1.20 Delay re-alarm function(ReALARM) : 4→4→1→1(DISABLE-ENABLE) →# 1.21 Key in no. to open (CARD) : 4→4→2→1(DISABLE-ENABLE) →# 1.22 Entry record setting(RECORD) : 4→4→3→1(DISABLE-ENABLE) →# 1.23 Relive alarm password setting(revive) : 4→4→4→1→1 (DISABLE-ENABLE) →# 1.24 Button tone (TONE) : 4→4→4→2→1(DISABLE-ENABLE) →# 1.25 Selection of open mode (ACCMOD) : 4→4→4→3→1(MODE2 →MODE 0

→MODE 1→# 1.26 Door sensor status (DOOR) : 4→4→4→4→1→1(NO-NC) →# 1.27 Clear all enroll card data and record(MEMORY ERASE) :

4→4→4→4→2→1→1→6 digit setting password → # 1.28 Clear card record(RECODE ERASE) : 4-→4→4→4→2→2→1→6 digit password →# 1.29 Date/Time Adjustment (CLOCK) : 4→4→4→4→3→by sequence keypad button 1

(decrease) keypad button 3 (increase) →# confirm to adjust mth/date/hour/min →# 1.30 Controller parameter copy(PARAMTER) : 4→4→4→4→4→1→1 1.31 Card data copy (PARAMTER) : 4→4→4→4→4→2→1

Page 12: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.201111

Display / Error / Warning message

WELCOME

Access Granted

Message displays when entitle to enter.

WARNING

Invalid Card

Message displays when using invalid card. Please enroll the card to become valid

card before use.

WARNING

Invalid Entry

1. Under Mode 0, it’s only for card holder access granted so by key in password

to enter, error message shows.

2. Wrong password please re-enter the correct password.

READY FOR CARD

DOOR OPEN

1. Once door open without closing, alarm will be activate and message will

display on screen. Please close the door to stop alarm.

2. Forced entry will activate the alarm sound to warn security guard if any

intruder.

READY FOR CARD

RELEASE ALARM

Message displays when release alarm code was enter to disarm.

Page 13: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.201112

+ + + In Guard + + +

Message displays when under “In Guard” mode.

READY FOR CARD

DOOR BELL ON

Message displays when door bell button is being push.

READY FOR CARD

FORCE ACCESS

Message displays when enter the door by forcing it to open and alarm

continuously beeping. By using valid card or key in disarm code can release the

alarm.

READY FOR CARD

TAMPER ALARM

Message displays when casing was dismantled and alarm sound continuously. By

using valid card or key in disarm code or mount back the casing can release the

alarm.

READY FOR CARD

ENTRY HALT

Message displays when entering wrong pass words for 5 times, keypad will halt

for 1 minute. By using valid card or wait for 1 min. to continue the process.

CARD PLEASE

Message displays when reading is in process.

Page 14: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.201113

Data Transfer

˙․․․․․

Message displays when data transfer is in process.

Data Receive

˙․․․․․

Message displays when data receiving is in process.

PARAMETER

Transfer Fail!

Message displays when controller parameter transfer fails, please check RS485

cable.

Data Transfer

Transfer Fail!

Message displays when data transfer fails, please check RS485 cable.

.

Page 15: HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.25.201114

FACTORY DEFAULT LIST

Description Factory Default

Access mode Mode 2 (Card data or password)

Master code 111111

Main password 1234

Revive Password 1234567

Guard Password 123

Personal Password 0000,refer to page 3

Strike Relay Active Time 5 sec.(0~255s, 0 is flash mode)

Alarm Relay Active Time 10 sec.(0~255s, 0 is last alarm)

Guard Relay Active Time 1 sec.(0~255s, 0 is LATCH mode)

Alarm relay activated of door left open 0 sec.(0~255s, 0 is dis-alarm)

Anti-duress alarm Active Time Same as Strike Relay

Tamper Alarm Disable

Force Entry / Exit alarm Disable

Alarm Disable

Guard Function Setting Disable

Guard Circle Detection Disable

Relay Alarm Disable

Press Card number to open the door Disable

Card Record Save Function Disable

Release Alarm Password Disable

Button Tone Enable

Door Sensor Status N/O

Date / Time Display Disable