15
HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60 HEART ENTERPRISE CO. LTD.

Upload: vuongmien

Post on 11-Apr-2018

270 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

0

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER

OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

HEART ENTERPRISE CO. LTD.

Page 2: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

1

Table of Contents

Features 2

Specification 3

Wiring Description 4

Installation 5

1.Wiring Diagram of HA3021(Security controller included) 5

2.Wiring Diagram of HA3021 6

Main Function Description 7

1.Basic operation 7

2.Card Management 7

3.Duress Function 7

4.Guard Function 7

5.Modify Personal password 7

6.Back-up password 8

Parameter Listing 9

Parameter setting 10

Display / Error/ Warning message 11

Factory Default List

14

Page 3: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

2

FEATURES 1. Proximity type reader, read range up to 10cm (4’’). 2. Proximity card are less prone to physical damage or loss. 3. Memory capacity store up to 5000 card holders. 4. LCD display ,16 characters×2 lines with back light

5. Three access mode options: (1). Mode 0: Card only (default). (2). Mode 1: Card and PIN.. (3). Mode 2: Card only or main password.

6. Anti-duress function : Card + personal password + random number or main password + random number With the anti-duress function provided, you no longer kidnap by thief. Key in a preset code to the rear, the duress relay will be activated to the require alarm device, other than the door opened normally.

7. Guard function : Guard password + Card The function can be used to arm/disarm the connected security system.

8. Personal Identification Number (PIN) Each card can be added with a four-digit PIN. This PIN is only valid when “Mode 1: Card and PIN of the access modes is selected, which provides higher security.

9. Lock out on invalid password To prevent unauthorized persons from gaining password entry by trial and error, the system activates an alarm relay and/or automatically deletes the card number after five tries, once the option id selected in the system.

10. Keypad pause function Keypad key in incorrect five times and no distance of 1min, keypad function will stop 1min and display

READY FOR CARD ENTRY HALT

11. User card can be registered /deleted in batch mode 12. Large 2-line LCD of 16 characters with back light feature including power saver

function: the back light will turn off if inactive for more than 3 minutes.. 13. Alarm to be activated once incorrect password key-in five times within four minutes. 14. Last 100 Access Granted card numbers can be viewed on-screen. 15. Strike, alarm and duress relay have selectable activation timer (00-255 seconds) 16. Selectable door left open timer(0-255 seconds) 17. Audible key tone available 18. For safety reason the * will be displayed when entering card number or PIN 19. Force entry alarm function available. 20. Tamper alarm function available. 21. Three-piece enclosure design the reader is patted for weather and hazard proofing 22. A separate relay module design, high security provided 23. Check the record in any time. 24. Open door to key-in Card number. 25. Build-in RS485, copy data by this controller parameter and enrolled card.

Page 4: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

3

SPECIFICATION

Input Voltage : DC +10V to 15V

DC Current : Average 135mA @12VDC; Peak 300mA @12VDC K1(Strike) & K2(Alarm) 0.4A @125VAC / 2A @30VDC

Contact Current : K3(Bell) & K4(Guard) 0.1A @100VAC / 0.5A @20VDC

Frequency (optional) : 125KHz、134.2KHz or 13.56MHz

Read Range : 1. 125KHz & 134.2KHz:Up to 7㎝ (In noise-free

environment)

2. 13.56MHz:Up to 5㎝ (In noise-free environment) *1 Keypad : 12 keys (0 ~ 9,*,#)

Display : 16 characters, 2 lines, LCD with backlight.

LED Indicator : Bicolor (Greed/Red)

Memory Capacity : 5000 cards (Including PIN) & last 100 transactions

Weight : 380g MAX

Operating humidity : 5%~95% (relative humidity, non-condensing)

Operating temperature : 0℃~70℃ / 32℉~158℉

Card type (optional)

: EM、HID、Mifare(ISO14443A)、TI-LF(134.2KHz) or

TI-HF(ISO15693) Case material : ABS (UL94V0)

Dimensions

: 150 x 110 x 45 mm / 5.9 x 4.3 x 1.8 in.

Remark: *1. Reduced read range with keytag and proximity sticker.

WIRING DESCRIPTION

Pin Wire Colore Function Description

1 Red V+ + 8.5V to 16V DC

2 Black GND Power Ground

3 Blown EXIT Exit Button

4 Orange STATUS Door Status Sensor

5 Yellow COM1 Strike Relay COM Strike Relay

Contact Selection 6 Green NC/NO1 Strike Relay NC/NO

7 Blue COMS Alarm Relay COM Alarm Relay

Contact selection 8 Purple NC/NO2 Alarm Relay NC/NO

Page 5: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

4

9 Grey COM3 Door Bell Relay COM

10 White NO3 Door Bell Relay NO

11 Light Blue COM4 Guard Relay COM

12 Light Green NO4 Guard Relay NO

13 Deep Pink Guard+ Guard Status Sensor(+)

14 Light Pink Guard- Guard Status Sensor(-)

NO

NC

Page 6: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

5

INSTALLATION

1. Wiring diagram of HA3021(Security controller included).

Page 7: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

6

2.HA3021 Wiring Diagram

Page 8: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

7

MAIN FUNCTION DESCRIPTION 1. Basic operation

MODE 0 – Card only – DEFAULT: This mode only requires the user to present his card to be granted access.

MODE 1 – Card and PIN: The mode requires that the user presents his card and then enters his PIN on the keypad. This mode is suitable for application s where higher security is needed.

MODE 2 – Card only or main password only: This mode will require that the user presents his card to the reader or enter main password using the keypad to be granted access.

Open the door by exit button: Opening the door just pressed the exit button. 2. Card Management Up to 5,000 user cards can be registered in the HA3021 system. All cards

are required to be registered in the system before use. Depending on how many cars you need to program, you can simply add them one at a time or use the batch process to ass a per-selected batch of cards in the system. For more information on cards, refer to the “Adding & Deleting Cards” section.

3. Duress Function:

The duress function is used to provide added security to personnel. In situations of duress, a cardholder presents his card to the reader, and then enters his PIN + any one-digit number (0-9) when the MODE1 of the access modes is selected. Or enter the master password + any one-digit number (0-9) when the MODE 2 of the access modes is selected.

Access Mode Duress operation procedures

1 MODE 0 – Card only Not available

2 MODE 1 – Card and PIN Card + PIN + (any one-digit number)+#

3 MODE 2 – Card only or main password only

Enter master password + (any one-digit number) +#

4. Guard Function: (Guard password + # + Card) HA3021 equipped a guard relay which can arm or disarm the connected security system. Use guard password or guard pass word plus card data to activate this function.

5. Modify Personal password:

1. MODE 1, display after sensor card

Page 9: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

8

Enter Password Code NO.:

2. And now enter * + old personal password (default: 0000)

New Password Code NO.:

3. Enter new password(4 digit) and enter # .

6. Back- up password: Back up password: 23400204 Key-in back up password and enter # when forgot the password, and then sensor the valid card, you will enter the setting mode. And setting password recover 1111( factory default ), controller have to least enroll one valid card. Operation: Key-in back-up password (23400204) + # + Card.

Page 10: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

9

PARAMETER LISTING The hierarchy diagram shows the relationship of each function

Main function Function 1 Function 2 Function 3 Function 4 Function 5 Function 6

1.ENROL 1.S-ADD 2.S-DEL 3.B-ADD 4.B-DEL

2.PASSWD 1.MASTER 2.MAIN 3.REVIVE 4.GUARD

3.TIMER

1.STRIKE 2.ALARM 3.DB 4.GUARD

1.ALARM 1.FORCE

2.TAMPER

3.P-ERR

4.DURESS

2.KNOCK

3.GUARD 1FUNCTION

2.GUARD CIRCUIT

4.OTHER

1.ReALARM

2.CARD

3.RECORD

4.SYSTEM 4.MORE

1.REVIVE

2.TONE

3.ACCMOD

4.MORE

1.DOOR

2.ERASE 1.MEMORY ERASE 2.RECORD ERASE

3.CLOCK

4.MORE

1.Databass Copy

1.PARAMTER 2.ENROLLED CARD

2.Hardware Test

Page 11: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

10

PARAMETER SETTING 1. Enrollment

Entry the parameter setting, press the “# “about three seconds and the monitor change enter “ 1 “, and then enter the following example assume the master code as "111111" (factory default) .

Add a new card(S_ADD) : 1→1→Card or password → #

Delete a card(S_DEL) : 1→2→ Card or password→ #

Add the cards in batch mode(B_ADD) : 1→3- Card serial no.1→ enroll card quantity you want. → #

Delete the cards in batch mode(B_DEL) : 1→4 → Card serial no.1 → delete quantity of card → #

Modify setting password(MASTER) : 2 →1 → random 6 digit number→ #

Modify main password(MAIN) : 1→1 random 4 digit number→ #

Modify relieve arm password(REVIVE) : 2→3 → random 7digit number→ #

Modify guard password(GUARD) : 2-→ 4 → random 3 digit→ #

Modify strike active time (STRIKE) : 3→1→ 0~255 sec. (0 sec. is flash mode) → #

Modify alarm active time(ALARM) : 3→2→0~255 sec. (0 sec. is last alarm) → #

Modify an interval time of door left open(DB) : 3 → 3→0~255 sec. (0 sec. ***)→#-

Modify security relay motion time(GUARD) : 3→4→0~255 sec. (0 sec. is flash mode)

Force entry setting enable/disable(FORCE) : 4→1→1→1(DISABLE-ENABLE) →#

Tamper alarm setting(TAMPER) : 4→1→2→1(DISABLE- ENABLE) →#

Alarm activated when incorrect password key-in five times(P_ERR) : 4→1→3→1(DISABLE-ENABLE) →#

Anti-duress alarm(DURESS) : 4-1-4-1(DISABLE-ENABLE) →#

(KNOCK) : 4→2→1(DISABLE- ENABLE) →#

Guard setting function(GUARD FUNCTION) : 4→3→1→1(DISABLE-ENABLE) →#

Guard circle status detection(GUARD CIRCLE) : 4→3→2→1(DISABLE-ENABLE) →#

Delay re-alarm function(ReALARM) : 4→4→1→1(DISABLE-ENABLE) →#

Press card number open(CARD) : 4→4→2→1(DISABLE-ENABLE) →#

Pass channel record setting(RECORD) : 4→4→3→1(DISABLE-ENABLE) →#

Relive alarm password setting(revive) : 4→4→4→1→1 (DISABLE-ENABLE) →#

Button tone (TONE) : 4→4→4→2→1(DISABLE-ENABLE) →#

Mode selection of open door(ACCMOD) : 4→4→4→3→1(MODE2 →MODE 0 →MODE 1→#

Door sensor status (DOOR) : 4→4→4→4→1→1(NO-NC) →#

Clear all enroll card data and record(MEMORY ERASE) : 4→4→4→4→2→1→1→6 digit setting password → #

Page 12: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

11

Clear card record(RECODE ERASE) : 4-→4→4→4→2→2→1→6 digit password →#

Date/Time(CLOCK) : 4→4→4→4→3→………. →#

Controller parameter copy(PARAMTER) : 4→4→4→4→4→1→1

Card data copy(parameter) : 4→4→4→4→4→2→1 :

Display / Error / Warning message

WELCOME

Access Granted

Normal Open

WARNING

Invalid Card

Card have to enroll procedure before or will display this wrong message.

WARNING

Invalid Entry

1. MODE 0 only for card but you key-in password, now you just use valid card .

2. Key-in the incorrect password.

READY FOR CARD

DOOR OPEN

1. When you open the door and forgot to closed, now the door left open alarm is

open, then you just close the door the alarm will stop.

2. When the Force Alarm is closed, door force to open, you just need to closed the

door.

READY FOR CARD

RELEASE ALARM

When key-in RELEASE ALARM PASSWORD, will display this message.

Page 13: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

12

+ + + In Guard + + +

Controller is on Guard situation currently.

READY FOR CARD

DOOR BELL ON

Doorbell is pressed.

READY FOR CARD

FORCE ACCESS

Force access alarm and display on screen, when the door force access, you can use

the valid card or release the alarm by release alarm password.

READY FOR CARD

TAMPER ALARM

Tamper Alarm and display on screen, when the casing was tampered, you can use

valid card keep going or put the casing back.

READY FOR CARD

ENTRY HALT

Key- in incorrect five times consecutively, keypad function will stop operation

function 1min,you can use valid card keep going or wait for 1min to star.

CARD PLEASE

Waiting for the read card.

Page 14: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

13

Data Transfer

˙․․․․․

Transfer the copy card no. data

Data Receive

˙․․․․․

Receive the copy card no. data.

PARAMETER

Transfer Fail!

Controller parameter transfer fail, please check RS485

Data Transfer

Transfer Fail!

Card no. transfer fail, please check RS485.

.

Page 15: HA3021 ALL-IN-ONE Proximity Stand Alone Controller · HA3021 ALL-IN-ONE Proximity Stand Alone Controller HEART ENTERPRISE CO., LTD. 7.14.2011 2 FEATURES 1. Proximity type reader,

HA3021 ALL-IN-ONE Proximity Stand Alone Controller

HEART ENTERPRISE CO., LTD. 7.14.2011

14

FACTORY DEFAULT LIST

Description Factory Default

Access mode Mode 2 (Card data or password)

Master code 111111

Main password 1234

Revive Password 1234567

Guard Password 123

Personal Password 0000,refer to the page 3

Strike Relay Active Time 5 sec.(0~255s, 0 is flash mode)

Alarm Relay Active Time 10 sec.(0~255s, 0 is last alarm)

Guard Relay Active Time 1 sec.(0~255s, 0 is LATCH mode)

Alarm relay activated of door left open 0 sec.(0~255s, 0 is dis-alarm)

Anti-duress alarm Active Time Same as Strike Relay

Tamper Alarm Disable

Force Entry / Exit alarm Disable

Alarm Disable

Guard Function Setting Disable

Guard Circle Detection Disable

Relay Alarm Disable

Press Card number to open the door Disable

Card Record Save Function Disable

Release Alarm Password Disable

Button tone Disable

NO

Display Date / Time Disable