gluex collaboration meeting. jefferson lab. september 9 – 11, 2004. review of tagger system

16
GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System.

Upload: kelly-watkins

Post on 13-Dec-2015

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

GlueX Collaboration Meeting.

Jefferson Lab.

September 9 – 11, 2004.

Review of

Tagger System.

Page 2: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Agenda.

1.Progress on tagger design. – Jim Kellie (15 mins.)

2.Discussion. – ( 15 mins.)

3. Design of two magnet tagger and vacuum system. – G. Yang ( 20 mins.)

4. Discussion. – (15 mins.)

5.General Discussion on Manpower/Time schedule/Funding. etc. – (25 mins.)

Page 3: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Progress On Tagger Design.

a)Tagger Options.

1. Design Report Specification.

2. Two Magnet Option.

3. Superconducting Option.

b) Conclusions.

Page 4: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Progress on tagger design.

1. Specification in Design Report. (Nov. 2002)

Field at 12 GeV 1.5 Tesla

Radius of curvature 26.7 m

Full-energy deflection 13.4 deg.

Gap width 2.0 cm

Length of pole 6.1 m

Weight ~100 tons

Length of focal plane 8.7 m

Coil Power 800 A at 22V.

Focal plane

(i) Set of 128 fixed scintillators covering 1 GeV to 9 GeV electron energy.( Photon range 3 to 11 GeV)

(ii) Moveable microscope of 64 counters covering for example photon range from 8 to 9 GeV.

Page 5: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

-4

-2

0

2

4

6

8

10

12

-4 -2 0 2 4

X-co-ord (m)

Y c

o-o

rd(m

)

Field=1.5 TBeam Energy =12 GeVBeam Bend= 13.4 degrees Tilt angle 84.degreesstraight Output Edge.

Length of Focal Plane(electron energy from 1GeV to 9 GeV) = 9.23 m

Object distance 3 m

12 GeV Tagger Design One magnet

Page 6: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Tagger with a single dipole magnet.

1. The design report parameters were confirmed to be optimal apart from increasing the object distance from 1.0 m to 3.0 m. This improves the resolution by almost a factor of ~30% and gives more room for the goniometer vacuum chamber , a quadrupole, and monitors if required.

2. 3-D TOSCA field calculations by P. Brindza and G. Yang confirmed magnetic field attainable with acceptable coil and yoke configurations.

3. Behavior of the effective magnetic field boundary is very predictable.

4. Preliminary vacuum system designs.

a) External to dipole magnet.

b) Use pole shoes as part of vacuum system.

c) Both welded and O-ring/welded systems considered.

Page 7: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Comments on Single Magnet Tagger.

Disadvantages.

a) Difficult to find a supplier of 6.5 m lengths of high quality magnetic iron.

b) Weight of top and bottom yoke pieces each in excess of 20 tons.

c) Difficult to design sufficient stiffness into such a long, thin structure.

d) Awkward to install.

Potential Solution.

Consider a 12 GeV tagger consisting of two identical uncomplicated magnets.

Page 8: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

-4

-2

0

2

4

6

8

10

12

-5 -3 -1 1 3 5

x co-ord (m)

y co

-ord

(m

)

`

Main beam energy 12 GeVBending angle 13.4 degreesObject distance 3 mTotal focal plane 10.3 m

Two identical magnets.Magnet length : 3.11 m

Focal planeLower part from 1-4.3 GeVLength 4.1m

Upper part from 4.3-9 GeVLength: 6.2 m

12 GeV Tagger Design 2 identical magnets

2. Two magnet option.

Page 9: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

0

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0 1 2 3 4 5 6 7 8 9 10

Electron Energy (GeV)

Re

so

luti

on

(%

)

one magnet

two identical magnets

0

1

2

3

4

5

6

7

0 1 2 3 4 5 6 7 8 9 10

Electron Energy (GeV)

Dis

pe

rsio

n (

cm

/%E

0)

one magnet

two identical magnets

12 GeV Tagger Design -Dispersion.

12 GeV Tagger Design-Resolution.

Page 10: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

0

2

4

6

8

10

12

14

16

18

20

0 1 2 3 4 5 6 7 8 9 10

Electron Energy (GeV)

Be

Ta

(d

eg

ree

s)

one magnet

two identical magnets

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

2

0 1 2 3 4 5 6 7 8 9 10

Electron energy (GeV)

Ve

rtic

al h

alf

he

igh

t a

t fo

ca

lpla

ne

(c

m)

one magnet

two identical magnets

12 GeV Tagger Design -Vertical height

12 GeV Tagger Design-Beta.

Page 11: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Comparison of single and 2 magnet systems.

• The focal plane geometry, resolution, dispersion and focal plane vertical height are very comparable.

• The angle beta is continuous for the single magnet tagger, but is discontinuous for the two magnets tagger.

• For GlueX energies beta is larger – and better - for the two magnets tagger.

• The difference between beta for the two options is at most 2 deg. and can be taken into account by the focal plane design.

• A two magnet design is optimal. For more than two, the dividing energy between magnets would interfere with the GlueX range of photon energies.

Page 12: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

f) The smaller magnets can be made by more manufacturers and would be cheaper.

g) Lower building costs. ( cheaper crane, smaller access doors etc.)

h) Both magnets could possibly run from a single power supply.

j) The two identical magnets tagger has several significant advantages and no serious disadvantages.

Page 13: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

3. Superconducing option.

( Increasing field reduces size of magnet and focal plane in proportion to the increase.)

Advantages.

(i) Jlab has expertise in superconducting magnet technology.

(ii) Smaller tagger hall.

(iii) Low power consumption.

Disadvantages.

(i) Room temperature magnet straightforward.

(ii) Reduction in size.

a) Focal plane moves closer to magnet – difficult to shield detectors.

b) Focal plane detectors become very small.ie:

Focal planeElectrons

Perpendicular to electrons

Angle at which electrons cross focal plane.~7deg

Page 14: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Field. Length perp. to electrons.

Focal plane. Fixed detectors. Microscope detectors

1.5 T 1.12 m ~9 mm ~2 mm

3.0 T ~0.55 m ~4.5 mm ~1 mm

(iii) A coil power consumption of ~17.6 kW is not excessive.

(iv) Cryogenics and liquid He required.

Page 15: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System

Conclusions

• We have carried out a comprehensive investigation into the design of a 12 GeV tagger for GlueX.

• The two identical dipole magnet tagger looks the best option, and fulfils the design criteria in the design report.

• Since the May Collaboration Meeting Glasgow has undertaken a more detailed design of the two magnet tagger and vacuum system.

Further work required.

(i) Alternative designs for vacuum system.

(ii) Focal plane design.

(iii) Design of support structure.

(iv) Production of preliminary engineering drawings.

(v) Specification of tagger hall.

(vi) Cost estimates.

Page 16: GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, 2004. Review of Tagger System