  • FITTING INSTRUCTIONS FOR ULTIMATE MOULDEDAND FLAT PLATE ACCESSORIESRead these instructions fully before commencing workand retain them for future reference.

    SAFETY INSTRUCTIONSThese accessories are to be installed in accordancewith the current edition of the IEE Wiring Regulations(BS 7671: Requirements for Electrical Installations) and appropriate statutory regulations.In the Republic of Ireland the installation must be inaccordance with the ETCI National Rules for Electricalinstallations ET 101.

    4. When mounting flat plate accessories, for the bestresults and visual appearance, it is recommendedthat prior to installation, the mounting surfacebeneath the accessory frontplate is first preparedto ensure that it is flat and all high spots have beenremoved.

    5. Certain accessories may require that the top andbottom lugs in 1 gang, 4 lug boxes, are bentinwards and out of the way to ensure the correctinstallation within the box.

    6. Always use cable of the correct rating and type.7. The layout of the terminal connections may differ

    between fittings, carefully check the location of theterminal connections before wiring.

    9. Secure the accessory to the wall by means of thefixing screws provided, positioning the cables inthe box so as to avoid them being trapped.

    10. Replace the appropriate fuse, or switch on theappropriate circuit breaker. Switch on the mainsisolator switch.

    IMPORTANT NOTICE WIRING COLOUR CHANGESAs from 1st April 2004 new installations in theU.K. could be wired using the new EU harmonisedcolours for the supply conductors of twin andearth cable:

    New colours Old coloursBROWN LIVE RED LIVEBLUE NEUTRAL BLACK NEUTRAL

    The old colours will cease to be used from 1st April 2006.

    10 AMP 1 GANG 2 WAY SWITCH (1 WAY SWITCHING)Connect the cables as shown in the wiring diagram.

    10 AMP 1 GANG 2 WAY SWITCH (2 WAY SWITCHING)Connect the cables as shown in the wiring diagram.

    10A 1 GANG 1 WAY AND 2 WAY SWITCH ADDITIONAL FITTING INSTRUCTIONS

    This switch has been designed for installing in a16mm deep wall box. It is therefore suitable forretrofit installations providing:a) Cables enter from the top of the wall boxb) Wall box does not protrude from the wall

    If cables enter from the side of the wall box thenit is likely that it will need replacing with a deeper25mm box.

    10 AMP 2 GANG AND 4 GANG 2 WAY SWITCHConnect the cables as shown in the wiring diagram.

    4 gang switch: Wire each circuit to individual switches.

    10 AMP 1 GANG INTERMEDIATE SWITCHIntermediate switches are used if more than two switchesare required to control a two way lighting circuit.They should be fitted between the first and last switcheson the circuit.One particular wiring arrangement, which may be used is shown in the following diagram.If replacing an existing switch, note the location of theterminals and the colour and position of cableconnections. Ensure that all cables are connected to the corresponding terminals on the new switch.

    10 AMP 1 GANG TRIPLE POLE DISCONNECTORFor use with extractor fans fitted with or without timercontrol. Provides local isolation for maintenance or repairwithout the need to isolate the complete circuit.Connect the cable conductors as shown in the wiringdiagram, ensuring that the correct polarity is maintainedbetween the load and supply conductors.For extractor fans without timers, there will only be twoload and two supply conductors.

    20 AMP DOUBLE POLE SWITCHESConnect the cables as shown in the wiring diagram.Ensure that the load cable is connected to the applianceWhen used on a ring main there will be two supply cables.Connect both of the cables to the same terminals.For switches with flex outlets, pass load cable throughoutlet before connecting to switch. Ensure cable clamp isfitted and tightened across outer sheath of cable.

    13 AMP SINGLE SWITCHED SOCKETConnect the cables as shown in the wiring diagram.The diagram shows connections for a ring main circuit.For radial circuits or a spur off a ring main there willonly be one cable.

    13 AMP UNSWITCHED SOCKETConnect the cables as shown in the wiring diagram.The diagram shows connections for a ring maincircuit. For radial circuits or a spur off a ring mainthere will only be one cable.

    13 AMP 2 GANG SWITCHED SOCKETConnect the cables as shown in the wiring diagram.The diagram shows connections for a ring main circuit.For radial circuits or a spur off a ring main there willonly be one cable.

    5 AMP SINGLE UNSWITCHED SOCKET ROUND PINConnect the cables as shown in the wiring diagram.Do not connect this socket directly to a ring maincircuit. It should only be connected to either a radialcircuit, protected by a MCB/fuse of the appropriaterating at the consumer unit/fuseboard, or spurred froma ring main and protected by a fused connection unitfitted with a fuse of the appropriate rating.

    G2515Top Intermediate Mod

    L

    L1 L2

    L

    L1 L2L3 L4

    L1 L2

    NOTE: IF YOU ARE IN ANY DOUBT ON HOW TOPROCEED, CONSULT A QUALIFIED ELECTRICIAN1. Switch OFF the mains supply and remove the

    appropriate fuse or switch off the appropriate circuitbreaker before commencing installation. Ensure thatno one else has access that would enable the supplyto be inadvertently reconnected.

    2. Remove the existing accessory from the wall (if usingthe new accessory to replace an old one).

    3. Remove any plaster debris and dust from the insideof the mounting box (wall box). Ensure that the headsof any box fixing screws do not protrude into the box.

    Individual conductor lengths shall be no longer than65mm including 10mm bared copper for termination.It is also recommended that the individual conductors,once connected, are dressed around the sides of theswitch to ease switch installation in the box.

    Ultimatemoulded and flat plate

    Ultimatemoulded and flat plate

    TO EARTH TERMINAL IN BOX

    LIVE

    SWITCHED LIVE

    SWITCHED LIVELIVE

    TO EARTH TERMINAL IN BOX

    LIVE

    SWITCHED LIVE LIVE

    TO EARTH TERMINAL IN BOX

    SWITCHED LIVE

    TO EARTH TERMINAL IN BOX

    SWITCHED LIVE LIVE

    TO EARTH TERMINAL IN BOX

    SWITCHED LIVE

    10 AMP 3 GANG 2 WAY SWITCHConnect the cables as shown in the wiring diagram.

    TO EARTH TERMINAL IN BOX

    LIVE

    SWITCHED LIVE

    TO EARTH TERMINAL IN BOX

    LIVE

    TO EARTH TERMINAL

    IN BOX

    NEUTRAL

    TO EARTH TERMINAL

    IN BOX

    NEUTRAL

    LIVE

    SUPPLY

    LIVE

    EARTH

    NEUTRALLIVE

    SUPPLY

    LOAD

    LIVE NEUTRAL

    EARTH

    TO EARTH TERMINAL IN BOX

    TO EARTH TERMINAL

    IN BOX

    EARTH NEUTRAL

    LIVE

    13 AMP 2 GANG UNSWITCHED SOCKETConnect the cables as shown in the wiring diagram.The diagram shows connections for a ring maincircuit. For radial circuits or a spur off a ring mainthere will only be one cable.

    NEUTRAL LIVE

    EARTH

    TO EARTH TERMINAL IN BOX

    NEUTRAL

    EARTH

    LIVE

    TO EARTH TERMINAL IN BOX

    LIVE

    EARTH

    NEUTRAL

    TO EARTH TERMINAL

    IN BOX

    LOAD

    Title

    Title

    2

    3

    4

    5

    6

    7

    8

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    FRONT

    print colour : PANTONE 647C (1 special only)

    9

    45 AMP COOKER CONTROL UNITThe product must be earthed.Connect the cables as shown in the wiring diagram.Ensure that the load cable is connected to theappliance. Do not connect this switch directly to a ring circuit.

    BARE COPPER MUST BE SHEATHED INGREEN/YELLOW SLEEVING.

    TO EARTH TERMINAL IN BOX

    SUPPLY

    LOAD

    EARTH LIVE

    NEUTRAL

    8. Accessories, particularly those with metal front plates,must be correctly earthed. This is achieved byconnecting the fixed earth wire to the earth terminalprovided on the accessory or on the metal plate andthen connecting a short length of wire from thisterminal to the terminal in the back box.

    NOTE: Some moulded plate switch accessories do not have earth terminals. In such cases, the fixedearth wires should be connected directly to the earthterminal in the back box.If the earth wire is bare it should be sheathed with a length of green/yellow sleeving.

    Flexible cable colours remain unchanged:BROWN LIVEBLUE NEUTRAL

    Eire conductor colours for twin and earth cableand flexible cable:BROWN LIVEBLUE NEUTRAL

    13 AMP DOUBLE POLE 2 GANG SWITCHED SOCKETConnect the cables as shown in the wiring diagram.The diagram shows connections for a ring main circuit.For radial circuits or a spur off a ring main there will only be one cable.

    LIVE NEUTRAL

    EARTH

    TO EARTH TERMINAL

    IN BOX

    13 AMP DOUBLE POLE 1 GANG SWITCHED SOCKETConnect the cables as shown in the wiring diagram.The diagram shows connections for a ring main circuit.For radial circuits or a spur off a ring main there will only be one cable. L N

    TO EARTH TERMINAL IN BOX

    EARTH NEUTRAL

    LIVE

    45 AMP COOKER CONNECTION UNITThe product must be earthed.Connect the cables as shown in the wiring diagram.Fit the cooker connection unit to the back box, andensure that the load cable is securely retained bythe cable clamp. Check and ensure that the loadcable is connected to the appliance. Before re-fittingthe front cover of the cooker connection unit,carefully remove the cable cut-out so that it fitsneatly around the load cable.Note ensure that all sharp edges are removed.

    BARE COPPER MUST BE SHEATHED INGREEN/YELLOW SLEEVING.

    45 AMP 1 AND 2 GANG SWITCHESThe product must be earthed.Connect the cables as shown in the wiring diagram.Ensure that the load cable is connected to theappliance. Do not connect this switch directly to aring circuit.

    BARE COPPER MUST BE SHEATHED INGREEN/YELLOW SLEEVING.

    TO EARTH TERMINAL

    IN BOX

    LIVE

    EARTH

    NEUTRAL

    SUPPLY

    LOAD

    NEUTRAL

    LIVE

    EARTH BARE COPPER

    SUPPLY CABLELOAD CABLE

    NEUTRAL

    LIVE

    EARTH BARE COPPER EARTH WIRE TOEARTH TERMINAL IN BOX

  • Recommended cable type: CT100 (or equivalent).

    13 AMP UNSWITCHED FUSED CONNECTION UNITFitted with a 13 Amp fuse. Connect the cables asshown in the wiring diagram. Ensure that the loadcable is connected to the appliance.

    When used on a ring main there will be two supplycables. Connect both of the cables to the sameterminals.

    For FCUs with flex outlets, pass load cable throughoutlet before connecting to switch. Ensure cable clampis fitted and tightened across outer sheath of cable.

    TELEPHONE SOCKETS1. Master sockets should only be fitted by an

    authorised engineer.2. Secondary sockets are for adding extensions. These

    may be from a master socket or from anothersecondary socket. The procedure is the same forboth arrangements. The maximum number ofextension sockets is normally 5.

    3. The unit is suitable for mounting on a 1 gang flush mounting box (wall box) with a minimum depth of 25mm.

    4. On the reverse side of the socket there are tworows of terminals numbered 1 to 6. Terminals areconnected using 4 core telephone cable.Terminals 2, 3, 4 and 5 on the master socket areconnected to terminals 2, 3, 4 and 5 on thesecondary socket. As long as the same cablecolour is used for the same terminal on eachsocket, the actual colours used are not important.

    5. Terminals will either be of the screw connectors orinsulation displacement connectors (IDC). To attachthe wire to IDC type terminals, position the wire asshown in Fig. 1, leaving 12mm overhanging.

    Press the wire into the connector using the toolprovided, and remove any excess wire.

    6. Telephone sockets fitted with metal front platesare fitted with earth terminals. The earthterminals on the socket should be connected tothe earth terminal in the wall box by means of ashort length of copper wire. If the wire is bare, itcould be sleeved with green/yellow sleeving.

    CO-AXIAL AND SATELLITE SOCKETSConnect the cables as shown in the wiring diagram.Carefully slit the outer cable sheath and peel back tothe required length. Remove the excess and exposethe underlying copper braided screen.Roll the braided screen over the top of the outersheath and trim back a short length of innerinsulation to expose the centre conductor. Slackenthe screws that retain the cable clamp and also thescrew that clamps the centre conductor.Position the cable so that the section covered by thebraided screen sits beneath the cable clamp and thecentre conductor sits within the centre conductor

    terminal. Tighten the screws on the cable clamp andtighten the centre conductor terminal screw. Ensurethat the braided screen does not come into contactwith the centre conductor terminal.In the case of accessories having metal front platesand fitted with earth terminals, the earth terminal onthe accessory should be connected to the earthterminal in the wall box by means of a short length ofcopper wire. If this wire is bare, it should be sleevedwith green/yellow sleeving.For 2 gang sockets, connect to each socketseparately, as described above.

    WIRING DIAGRAM FOR CO-AXIAL SOCKETS WIRING DIAGRAM FOR SATELLITE SOCKETS

    RJ45 DATA OUTLETSThese accessories require a minimum box depth of35mm. On the reverse of the accessory, remove the topcover to expose the terminal connectors. There are tworows of terminals, each having a number of colourcoded connectors. Determine whether the wiringscheme is T568A or T568B and use the appropriatecolour code guide to identify the correct position of eachof the cables. To attach the wire to the terminalconnectors, position the wire as shown in Fig 2. Pressthe wire into the connector using the tool provided. Onceall cables are connected, remove any excess wire andreplace the top cover. In the case of accessories having

    metal front plates and fitted with earth terminals, theearth terminal on the accessory should be connectedto the earth terminal in the wall box by means of ashort length of copper wire. If this wire is bare, itshould be sleeved with green/yellow sleeving.

    1 AND 2 GANG BLANK PLATESIf using the blank plate to cover the position of anexisting accessory, ensure that any remainingcables are isolated and terminated at a convenientjunction. Where possible remove the cables frominside the wall box. If the cable cannot be isolated,ensure that the bare ends of the live and neutralcables are terminated separately, within suitablysized terminal blocks. The terminal blocks shouldthen be covered with insulating tape for additionalsafety. Any earth cables must be sheathed ingreen/yellow sleeving and connected to the earth

    terminal in the wall box. In all instances, it isimportant that the earthing circuit is maintainedwhen removing an accessory.

    If the accessory to be removed is on a ring main it isimportant that, after removal, the connections for thering circuit are maintained. This can be achieved byconnecting all the live cables together, and then all theneutral cables together with suitably sized terminalblocks. The terminal blocks should then be coveredwith insulating tape for additional safety. All earthcables must be sheathed in green/yellow sleeving andconnected to the earth terminal in the wall box.

    In the case of metal blanking plates fitted with earthterminals, the earth terminal on the plate should beconnected to the earth terminal in the wall box bymeans of a short length of copper wire.*BARE COPPER MUST BE SHEATHED INGREEN/YELLOW SLEEVING

    TO EARTH TERMINAL

    IN BOX

    EARTH

    LIVE

    NEUTRAL

    Fig 1. - Connection Block

    TERMINAL FOR CENTRAL CONDUCTOR

    CABLE BRAID TRAPPED UNDER CABLE CLAMP

    CABLE CLAMP

    COAXIAL CABLE

    TERMINAL FOR CENTRAL CONDUCTOR

    TO EARTHTERMINAL

    IN BOX METAL

    PLATES ONLY

    METALBACKING

    PLATE

    CABLE CLAMP

    LOAD

    SUPPLY

    AR1005 Ed E

    GET PLC, Key Point, 3-17 High Street, Potters Bar, Hertfordshire, EN6 5AJ, EnglandHelpline Telephone 0121 565 7770

    www.getplc.com

    1 GANG 2 GANG

    Any unauthorised reproduction of this booklet, inwhole or part will be a breach of copyright and other intellectual property rights and infringementproceedings may be instituted to protect suchintellectual property rights.

    3. The product is not kept or used in areas of high humidity.

    4. The product has not been misused or handledcarelessly.

    5. The product has not been tampered with.6. The product has been properly installed in

    accordance with the relevant wiring regulationsand installation practices.

    This Guarantee does not affect your statutoryrights other than those expressly set out aboveand does not cover any claims for consequentialloss or damage.

    31

    25

    26

    27

    28

    29

    30

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    48

    BACK

    print colour : PANTONE 647C (1 special only)

    DIPLEXER AND TRIPLEXER

    1. Undo the screw to remove the terminal cover onthe rear of the socket.

    2. Remove 20mm of outer cable sheath and triminner insulation to expose 10mm of the centralconductor.

    3. Ensure that any excess braided screen iswrapped around the inner insulation and is nottouching the central conductor.

    4. Push the centre conductor of the co-axial cableinto the terminal.

    5. Position the cable so that the section covered bythe braided screen sits beneath the cable clamp.Ensure that the braided screen does not come incontact with the centre conductor terminal. Refitand tighten the terminal cover, clamping thebraided screen beneath.

    6. In the case of accessories having metal frontplates and fitted with earth terminals, the earthterminal on the accessory should be connected to the earth terminal in the wall box by means of a short length of copper wire. If this wire is bare,it should be sleeved with green/yellow sleeving.

    CABLE

    BRAIDEDSCREEN

    MODULE

    CABLECLAMP

    GUARANTEEThis product except for the dimmer switch isguaranteed for 25 years from the date of purchaseagainst faulty materials or workmanship. Duringthis period it will be repaired or replaced free ofcharge providing that:1. The product is returned to GET via the electrical

    wholesaler from whom the product wasoriginally purchased, together with proof ofpurchase.

    2. The product has been used for its intendedpurpose and connected to a mass supply of220-240 volts.

    13 AMP SWITCHED FUSED CONNECTION UNITFitted with a 13 Amp fuse. Connect the cables asshown in the wiring diagram. Ensure that the loadcable is connected to the appliance.

    When used on a ring main there will be two supplycables. Connect both of the cables to the sameterminals.

    For FCUs with flex outlets, pass load cable throughoutlet before connecting to switch. Ensure cable clampis fitted and tightened across outer sheath of cable.

    TO EARTH TERMINAL IN BOX

    NEUTRAL

    EARTH

    LIVESUPPLY

    LOADLIVE

    25 AMP FLEX OUTLET PLATEThe product must be earthed. Connect the cables asshown in the wiring diagram.If required carefully remove the cable cut-out, on theside of the frontplate so that the load cable fitsneatly within it.NOTE: Ensure that all sharp edges are removed!Before fitting frontplate, ensure that the load cable issecurely retained by the cable clamp. Check that theload cable is connected to the appliance.

    ALL EARTH CONDUCTORS MUST BE SHEATHED INGREEN/YELLOW SLEEVING.

    20 AMP FLEX OUTLETConnect the cables as shown in the wiring diagram. Ensure that the load cable is connected to theappliance. Pass the load cable through the flexoutbefore connecting to terminals on rear of the plate.Ensure that the cable clamp is fitted and thightenedacross the outer sheath of the cable.

    APPLIANCE

    APPLIANCE

    TO EARTH TERMINAL IN BOX

    NEUTRALLIVEEARTH

    NEUTRALEARTHLIVE

    LOADCABLE

    SUPPLY CABLE

    DIMMERSImportant Safety Fitting Instructions1. Before commencing work, isolate the circuit.2. Do not overload or underload the dimmer.3. Use the correct type of dimmer for the connected load.4. Isolate supply before installing or removing bulb.

    Dimmer Switch Installation1. Disconnect wires from the old switch.2. On square, four lugged boxes, bend the top and

    bottom lugs inwards and out of the way.

    3. Install the dimmers as shown in the relevant wiringdiagram, ensuring that no wires are trapped betweenthe plate and the box. The earth terminal on the platemust be connected to the earth terminal in the box.Fix the plate with the screws provided.Do not over tighten the fixing screws.

    4. Re-connect the power to the circuit and test operation.5. It is normal for a faint buzzing sound to be heard from

    a dimmer switch. This is from the radio interferencesuppression coil and is no case for concern.

    CIRCUIT AND OTHER EQUIPMENT COMPATIBILITY To ensure optimum performance and reliability is obtainedfrom this dimmer switch during its lifetime the followingrecommendations and precautions should be followed asappropriate to the type of dimmer:

    CIRCUITSIt is recommended that the lighting circuit incorporatingthis dimmer is protected by a 6A or up to a 10Amaximum Type B miniature circuit breaker.Only use two-way (push) dimmers in two-way switchingcircuits. Only use one two-way dimmer in a two-wayswitching circuit.

    LAMPSThese dimmer switches are suitable for dimmingincandescent lamps and dimmable CFL lamps only and are NOT to be used with Fluorescent lamps,Light Emitting Diode (LED) lamps of any description or motor loads.When using mains voltage Tungsten Halogen lamps, it isessential that these types of lamps incorporate internalfuses and are from quality lamp manufacturers. The useof inferior low quality lamps without internal fuses is notrecommended and will invalidate any guarantee orwarranty supplied with the dimmer switch.

    Unless Compact Fluorescent (CFL) lamps are markedDimmable they must NOT be used with these dimmerswitches. Use of non-dimmable CFL lamps maypermanently damage the dimmer or the lamp and willinvalidate any guarantee or warranty supplied with thedimmer switch.It is recommended that a maximum number of 5dimming CFL lamps only should be connected to anindividual dimmer switch.

    LOW VOLTAGE TRANSFORMERSOnly use Low Voltage dimmers with transformers. Donot use mains voltage dimmers.Always check transformer compatibility BEFOREinstallation and if in doubt always check with thedimmer Helpline or the transformer manufacturerThe Low Voltage dimmer switches use leading edge(phase delay) dimming technology and must thereforebe used with compatible good quality dimmableelectronic or wire-wound transformers. Trailing edge(phase cut) dimmable transformers must not be used.

    Do NOT mix electronic and magnetic transformers onthe same dimmer switch.It is recommended that a maximum number of 5 LowVoltage transformers should only be connected to anindividual dimmer switch.It is recommended that dimmable electronictransformers be loaded to at least 70% of their ratedmaximum wattage.

    LOADING TABLEPLATE SIZE No. of Dimmers Max. each Dimmer Min.each Dimmer Total per Plate

    1 250W/VA 60W/VA 250W/VA1 400W/VA 60W/VA 400W/VA2 250W/VA 60W/VA 500W/VA

    Maximum load of 500W/VA for the plate should not be exceeded.

    PLATE SIZE No. of Dimmers Max. each Dimmer Min.each Dimmer Total per Plate3 250W/VA 60W/VA 750W/VA4 250W/VA 60W/VA 1000W/VA

    Maximum load of 1000W/VA for the plate should not be exceeded.

    NOTE: The dimmer VA rating refers to the total circuit load, not the lamp load. Allowances must be made for transformerlosses typically 20% for wire wound laminated and toroidal transformers and 15% for dimmable electronic transformers.

    When running multiple lamps on dimmable electronictransformers ensure that all lamps are working correctly.Replace failed lamps as soon as possible as a singlefailed lamp may cause flickering of other lamps.

    INSTALLATION WIRING DIAGRAM1 WAY DIMMERConnect the cables as shown in the wiring diagram.

    INSTALLATION WIRING DIAGRAM2 WAY DIMMERS WIRED IN 1 WAY CIRCUITConnect the cables as shown in the wiring diagram.

    LAMP MAINS SUPPLY

    TO EARTH TERMINAL IN BOX

    INSTALLATION WIRING DIAGRAM2 WAY DIMMERS WIRED IN 2 WAY CIRCUITConnect the cables as shown in the wiring diagram.

    C

    LAMPMAINS SUPPLY

    TO EARTH TERMINAL IN BOX

    LAMP MAINS SUPPLY

    TO EARTH TERMINAL IN BOX