general purpose motors, single phase, rolled steel ... filemotor mechanical d at a ... ** 56h nema...
TRANSCRIPT
No.:
Date: 6/16/2011
TECHNICAL PROPOSAL
General Purpose Motors, Single Phase,Rolled Steel, Standard Efficiency, ODP
Customer :
Product line : Single-Phase : NEMA 48 & 56 ODP
Catalog Number : 00718OS1CCD215TList Price : $961
Notes:Single-Phase : NEMA 48 & 5 ODP6
Performed by: Checked:
INDUSTRIAL POWER SUPPLY
Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com
No.:
Date: 6/16/2011
DATA SHEETGeneral Purpose Motors, Single Phase, Rolled Steel, Standard E�ciency, ODP
Customer :Product line : De�nite Purpose : Single-Phase - ODP
: 7.5 HP: 1800 RPM: 215T: 1.15: 30.6 A: 19.66 in: 230-460V: 1: ODP: Foot Mount: Standard: Squirrel cage rotor: CE, UL, CSA: RAL 7022 – Dark Gray: Yes: B: Ball bearings: Continuous Duty S1: 40 ºC: 3300 ft (1000 m): IP21: 85 %: Rolled Steel: 60 Hz: F1 mounting T-Box: Stainless steel nameplate AISI 316 with laser etching: Enamel alkyd resin base: 1045 carbon steel shaft: B: NEMA: NPT threaded terminal box: Automatic drain plugs: V-ring slingers on both endshields: 4: H: 130 lbs
Notes:
Performed by: Checked:
INDUSTRIAL POWER SUPPLY
Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com
HP RPM Frame Service FactorFL Amps @ High'C' DimensionVoltagePhasesEnclosure BaseE�ciency RatingRotorCerti�cationsColorStart CapacitorInsulation ClassBearingsDutyAmbient TemperatureAltitudeDegree of ProtectionFL E�ciencyFrame MaterialFrequencyMounting NameplatePaintShaftTemperature Rise ClassDimensionsTerminal BoxDrain PlugsV-ring SlingersPolesImpregnation resin insulation classApprox. Shipping Weight
Data subject to change without notice. B-45
MO
TOR
MEC
HA
NIC
AL
DAT
A
GENERAL PURPOSE MOTORS – NEMA 48 & 56 ODP
MECHANICAL DATA
NEMAFRAME
MOUNTINGA B C D O P XO
KEY WAY SHAFT EXTENSION BEARINGS
2E 2F BA S R ES N-W U D.E. O.D.E.
B484,236 2,748 2,500 6,141 3,543
9,4093,000 5,905
5,748 1,516
* * * 1,500 0.5000
6203-ZZ 6202-ZZC48 10,197
56
4,875
3,000
2,750 6,535
4,015
9,764
3,500
6,378
0.187 0.517 1,102 1,874 0.6250
C56 10,551
A56 10,315
6,772 6,535 6204-ZZ 6203-ZZ
B56 11,1021,516
D56 12,283
F56H 3,0006,496
13,4641,300
G56H 5000** 13,858
“C” FLANGE DIMENSIONS
FLANGE AJ AK BDBF
AHNUMBER TAP
SIZE
FC-95 3,748 3,000 5,6294
UNC1/4” 1,689
FC-149 5,874 4,500 6,496 UNC3/8” 2,063
* THE SHAFT OF NEMA 48 FRAME MOTORS SHOWS A FLAT CHANFER WITH 0.291” OF WIDTH INSTEAD OFF THE KEYWAY.
** 56H NEMA IS PROVIDED WITH A DOUBLE HOLED BASE - DIMENSION B: 3” AND 5”.
Data subject to change without notice. www.weg.netB-58
MO
TOR
TECHN
ICAL D
ATA
Data subject to change without notice.
MECHANICAL DATA
GENERAL PURPOSE SINGLE PHASE MOTORS – ODPNEMA “T”
GENERAL PURPOSE SINGLE PHASE MOTORS –TEFCNEMA “T”
NEMAFRAMES
MOUNTINGA B C D G J K O P T
KEYWAY SHAFT EXTENSION AB AA D1
BEARINGS
2E 2F H BA S R ES N-W U D.E. O.D.E.
W182/4T7.500
4.500
0.406
2.7508.661 6.968
17.2444.500 0.630 1.890
2.4418.267
7.800
1.772
0.250 0.984 1.968 2.750 1.1257.362
NPT 1” A 4
6206-ZZ
6206-ZZ
5.500184T 5.500
3.500
17.050 1.968 8.820 7.835 6307-ZZ
W213/5T
8.500
5.500
9.765 8.87521.000
5.250 0.830 2.0003.343
9.6108.820
0.313 1.203 2.480
3.375
1.3757.953
6308-ZZ7.000
W213/5TZ 5.500 0.250 0.986 1.968 1.125
7.000215T 2.75019.567 2.165 10.630
0.313 1.203 2.480 1.3759.055
215TZ 3.500 0.250 0.986 1.968 1.125
2E 2F H BA S R ES N-W U D.E. O.D.E.
182T 4.500 5.905 14.448
184T 5.500 6.889 14.8706205-ZZ7.925 NPT1" A4 6206-ZZ0.984 1.771 2.750 1.1259.382 8.968 1.772 0.250
d1BEARINGS
7.500 0.406 2.750 8.653 4.500 0.500 1.929 1.850
KEYWAY SHAFT EXTENSIONAB AAK O P TC D G JNEMA
FRAMES
MOUNTINGA B
Data subject to change without notice. www.weg.netB-2
MO
TOR
ELECTRICAL D
ATA
Data subject to change without notice.
GENERAL PURPOSE MOTORS NEMA 48 & 56ODP – SINGLE PHASE
The values shown are subject to change without prior notice. To obtain guaranteed values, please contact our nearest sales offi ce.
ELECTRICAL DATA
RATED OUTPUT NEMA
FRAME
RATEDSPEED
FULL LOADCURRENT
INA
KLOCKEDROTOR
CURRENTKVA
CODE
FULLLOAD
TORQUETN
LB.FT
LOCKEDROTOR
TORQUETL / TN
BREAK-DOWN
TORQUETB / TN
EFFICIENCY% OF FULL LOAD
POWER FACTOR% OF FULL LOAD SERVICE
FACTORSF
MOMENTOF INERTIA
WK2LB.FT2
APPROX.WEIGHT
HP KW RPM AT 115 V
AT 230 V 50 75 100 50 75 100 LB
0.12 0.09 B48 1750 3.20 1.60 P 0.36 3.4 3.2 33.0 41.0 48.1 0.40 0.46 0.52 1.40 0.02420 17
0.16 0.12B48 3440 3.10 1.55 M 0.24 3.6 3.0 37.0 43.0 49.9 0.55 0.60 0.69 1.35 0.01281 16B48 1740 3.70 1.85 N 0.48 3.6 2.9 38.0 46.5 50.3 0.41 0.48 0.55 1.35 0.02800 18
0.25 0.18B48 3440 4.30 2.15 M 0.38 3.5 2.8 42.0 50.5 54.7 0.56 0.64 0.68 1.35 0.01495 18B48 1740 5.30 2.65 N 0.74 3.2 2.6 40.5 48.5 55.9 0.40 0.48 0.54 1.35 0.03204 20
0.33 0.25C48 3480 5.70 2.85 N 0.49 3.8 3.0 46.5 54.1 57.6 0.49 0.59 0.65 1.35 0.01898 21C48 1745 6.60 3.30 N 0.98 3.5 2.8 45.5 53.5 58.2 0.39 0.47 0.55 1.35 0.04010 21
0.5 0.37C48 3470 7.20 3.60 L 0.75 3.8 3.0 53.5 60.7 64.4 0.52 0.61 0.69 1.25 0.02326 23C48 1730 8.50 4.25 M 1.50 3.3 2.4 53.0 59.0 61.7 0.43 0.52 0.61 1.25 0.04817 24
0.75 0.55B56 3525 10.5 5.25 L 1.10 2.5 2.8 56.5 64.2 67.2 0.52 0.61 0.68 1.25 0.03322 28D56 1745 12.0 6.00 M 2.23 2.7 2.6 57.7 65.9 66.7 0.41 0.51 0.60 1.25 0.10702 31
1 0.75D56 3520 13.6 6.80 M 1.47 2.8 2.9 54.5 62.1 66.3 0.53 0.63 0.71 1.25 0.04153 33D56 1740 14.0 7.00 L 2.98 2.7 2.6 64.2 70.0 71.4 0.44 0.56 0.64 1.15 0.13384 35
1.5 1.1D56 3500 17.8 8.90 L 2.22 2.5 2.4 61.5 67.5 70.0 0.58 0.69 0.77 1.15 0.04983 38
F56H 1740 20.4 10.2 L 4.47 2.8 2.5 65.5 71.1 71.3 0.46 0.57 0.66 1.15 0.19554 42
2 1.5F56H 3525 21.9 11.0 M 2.94 2.5 2.8 71.1 76.2 77.9 0.59 0.67 0.75 1.15 0.06644 49G56H 1730 28.0 14.0 L 5.99 2.5 2.5 64.3 70.6 71.4 0.42 0.53 0.64 1.00 0.23018 48
3 2.2 G56H 3490 31.0 15.5 K 4.45 2.3 2.4 74.9 77.8 77.4 0.61 0.73 0.80 1.00 0.07214 44
GENERAL PURPOSE MOTORS – NEMA 56TEFC – SINGLE PHASE
RATED OUTPUT NEMA
FRAME
RATEDSPEED
FULL LOADCURRENT
IN A
LOCKEDROTOR
CURRENTKVA
CODE
FULLLOAD
TORQUETN
LB.FT
LOCKEDROTOR
TORQUETL / TN
BREAK-DOWN
TORQUETB / TN
EFFICIENCY% OF FULL LOAD
POWER FACTOR% OF FULL LOAD
SERVICEFACTOR
SF
MOMENTOF INERTIA
WK2LB.FT2
APPROX.WEIGHT
LBHP KW RPM AT
115 VAT
230 V 50 75 100 50 75 100
0.25 0.18B56 3480 4.60 2.30 N 0.37 2.8 2.9 36.0 45.0 50.0 0.56 0.64 0.70 1.15 0.02373 22
B56 1750 4.70 2.35 P 0.74 3.6 2.8 45.0 53.0 57.7 0.41 0.50 0.58 1.15 0.05363 20
0.33 0.25B56 3490 5.70 2.85 N 0.49 3.7 3.2 40.0 49.0 53.0 0.56 0.64 0.70 1.15 0.02776 22
B56 1750 5.60 2.80 N 0.98 3.4 2.8 49.0 58.0 61.0 0.44 0.53 0.62 1.15 0.06241 22
0.5 0.37
B56 3480 7.60 3.80 L 0.74 3.2 2.8 45.0 52.0 58.0 0.56 0.66 0.73 1.15 0.03156 23
B56 1750 7.40 3.70 L 1.48 2.9 2.7 56.0 64.0 66.5 0.46 0.57 0.65 1.15 0.08044 25
D56 1180 7.20 3.60 L 2.20 2.5 3.0 58.0 67.0 71.0 0.47 0.55 0.63 1.15 0.14285 38
0.75 0.55
B56 3490 10.4 5.20 M 1.11 3.0 2.9 52.0 60.0 64.0 0.54 0.64 0.72 1.15 0.03963 26
B56 1745 10.6 5.30 M 2.23 3.0 2.5 58.5 66.0 68.5 0.47 0.58 0.66 1.15 0.09824 28
F56H 1170 10.0 5.00 K 3.32 2.3 2.6 59.0 67.0 71.0 0.49 0.59 0.68 1.15 0.17774 42
1 0.75
D56 3500 12.8 6.40 M 1.48 3.2 2.8 55.0 63.0 67.0 0.56 0.67 0.75 1.15 0.05149 32
D56 1750 14.0 7.00 M 2.96 3.2 2.7 60.0 67.0 70.3 0.45 0.56 0.65 1.15 0.13384 34
G56H 1150 11.0 5.50 J 4.51 2.4 2.2 64.0 69.0 73.0 0.63 0.72 0.80 1.15 0.21333 49
1.5 1.1D56* 3480 17.1 8.55 K 2.23 2.5 2.5 62.0 69.0 70.0 0.61 0.72 0.80 1.15 0.05933 35
F56H 1750 17.4 8.70 K 4.44 2.8 2.6 70.0 75.0 76.5 0.52 0.64 0.72 1.15 0.19554 47
2 1.5F56H 3480 20.0 10.0 K 2.98 2.7 2.4 69.0 73.0 74.0 0.72 0.81 0.87 1.15 0.07902 44
G56H 1750 21.0 10.5 K 5.92 2.8 2.5 74.0 78.0 78.1 0.60 0.71 0.78 1.15 0.21333 50
3 2.2 G56H* 3480 26.0 13.0 J 4.47 2.5 2.5 75.0 79.0 80.0 0.82 0.90 0.93 1.15 0.09492 51
* DT = 105K
B-13Data subject to change without notice.
MO
TOR
ELEC
TRIC
AL
DAT
A
GENERAL PURPOSE MOTORS – NEMA “ T”ODP – SINGLE PHASE
ELECTRICAL DATA
GENERAL PURPOSE MOTORS – NEMA “ T”TEFC – SINGLE PHASE
RATED OUTPUT
NEMAFRAME
RATED SPEED
FULL LOAD CURRENT
IN A
LOCKED ROTOR
CURRENT KVA
CODE
FULL LOAD
TORQUE TN
LB.FT
LOCKED ROTOR
TORQUE TL / TN
BREAK-DOWN
TORQUE TB / TN
EFFICIENCY POWER FACTOR
SERVICE FACTOR
SF
MOMENT OF INERTIA
WK2 LB.FT2
APPROX. WEIGHT
% OF FULL LOAD
HP KW RPMAT
115 V
AT 230
V50 75 100 50 75 100 LB
0.5 0.37 143T 3530 7.60 3.80 N 0.73 2.7 2.4 50.0 56.0 60.0 0.56 0.65 0.71 1.15 0.02373 42
1 0.75143T 3510 12.6 6.30 L 1.48 2.4 2.4 57.0 63.0 67.0 0.62 0.71 0.77 1.15 0.03560 46143T 1760 11.2 5.60 L 2.94 2.8 2.7 65.0 72.0 74.0 0.61 0.71 0.79 1.15 0.09255 54
1.5 1.1143T 3535 15.2 7.60 K 2.20 2.4 2.8 68.0 73.5 76.0 0.70 0.81 0.85 1.15 0.04746 53145T 1760 14.4 7.20 L 4.42 2.5 2.9 65.0 72.0 76.0 0.76 0.82 0.87 1.15 0.12340 62182T 1180 19.0 9.50 K 6.59 2.2 2.6 60.0 68.0 72.0 0.53 0.62 0.70 1.15 0.34575 88
2 1.5145T 3530 19.2 9.60 J 2.94 2.7 2.8 72.0 75.5 79.0 0.74 0.84 0.86 1.15 0.05695 55145T 1740 19.0 9.50 J 5.96 2.3 2.3 69.0 74.0 76.0 0.75 0.85 0.90 1.15 0.19933 64213T 1160 20.0 10.0 K 8.93 2.4 2.3 68.0 75.0 80.0 0.68 0.75 0.80 1.15 0.53155 118
3 2.2
145T 3500 26.8 13.4 J 4.44 2.3 2.5 75.0 79.0 79.5 0.81 0.86 0.90 1.15 0.08068 60182T 3490 27.0 13.5 J 4.45 2.6 2.6 75.0 77.0 78.0 0.84 0.88 0.91 1.15 0.15187 87184T 1745 26.6 13.3 J 8.91 3.0 2.6 70.0 75.0 78.0 0.82 0.89 0.92 1.15 0.31561 89
W182/4T 1750 28.0 14.0 J 8.88 2.9 2.4 75.0 79.0 80.0 0.70 0.80 0.85 1.15 0.23730 88215T 1165 26.0 13.0 G 13.3 2.3 2.2 71.0 78.0 82.0 0.84 0.89 0.90 1.15 0.61935 162
5 3.7
184T 3500 42.0 21.0 H 7.40 2.8 2.6 79.0 81.0 83.0 0.80 0.88 0.92 1.15 0.19530 102184T 1730 42.0 21.0 H 15.0 2.9 2.4 75.0 78.0 80.0 0.86 0.92 0.95 1.15 0.42714 113
215TZ 1730 42.0 21.0 H 15.0 2.9 2.4 75.0 78.0 80.0 0.86 0.92 0.95 1.15 0.44375 128215T 1160 44.0 22.0 H 22.3 2.3 2.3 76.0 81.0 82.0 0.80 0.86 0.88 1.15 1.78450 166
7.5 5.5
184T 3495 61.8 30.9 H 11.1 2.8 2.6 79.0 83.0 84.0 0.82 0.89 0.92 1.15 0.57664 110213T 3495 61.8 30.9 H 11.1 2.8 2.6 79.0 83.0 84.0 0.82 0.89 0.92 1.15 0.57664 110
215TZ 1735 68.0 34.0 H 22.4 3.2 2.5 75.0 80.0 82.0 0.71 0.81 0.86 1.15 0.90649 161215T 1735 68.0 34.0 H 22.4 3.2 2.5 75.0 80.0 82.0 0.71 0.81 0.86 1.15 0.90649 157
10 7.5215T 3520 79.6 39.8 H 14.7 2.1 2.6 81.5 85.1 86.2 0.91 0.93 0.95 1.15 0.57664 157215T 1720 80.0 40.0 G 30.1 2.7 2.2 78.0 82.0 83.0 0.93 0.96 0.97 1.15 1.18650 180
12.5 9.2215T 3520 94.6 47.3 H 18.4 1.6 2.9 86.0 87.5 89.0 0.91 0.93 0.95 1.15 0.75699 176215T* 1730 95.6 47.8 G 37.4 2.2 2.4 79.0 84.0 85.3 0.95 0.96 0.98 1.15 1.33363 192
* DT 105K
OUTPUT RATED SPEED (RPM)
FRAMEFULL
AT 230V
FULL LOAD TORQUE (FT.LB)
LOCKED ROTOR
CURRENTLOCKED ROTOR
TORQUE TL/TN
BREAK-DOWN
TORQUE TB/TN
EFFICIENCY POWER FACTOR
SERVICE FACTOR
SF
INERCIA J (SQ.FT.LB)
ALLOWABLE LOCKED
ROTOR TIME (S)
WEIGHT (LB)
% OF FULL LOAD
HP KWCODE
IL/IN 50 75 100 50 75 100
HOT COLD
3 2.2182T 3520 15 4.42 J 6.4 2.3 2.6 78 81 81.5 0 0.71 0.79 1.25 0.18035 6 13 85.7
184T 1750 17.5 8.88 K 6.5 2.1 2 71 74 75 0.56 0.68 0.75 1.25 0.43189 6 13 106
5 3.7184T 3500 21 7.4 G 6.5 2.6 2 80 81.5 81.5 0.85 0.91 0.92 1.25 0.25628 6 13 102
184T 1745 21.5 14.8 H 6.5 2.2 2 81.5 82.5 82.5 0.82 0.87 0.91 1.25 0.49833 6 13 115
7.5 5.5 184T 3510 30 11.1 H 7.2 2.4 2.3 82 84 85 0.9 0.93 0.95 1.25 0.29425 6 13 112
Typical Wiring Diagrams - Single-Phase MotorsAlways use wiring diagram supplied on motor nameplate.
Dual Voltage / Reversible Rotation
With Thermal Overload Protection
Dual Voltage / Single Rotation
Without Thermal Overload Protection
Dual Voltage / Reversible Rotation Dual Voltage / Single Rotation
Single Voltage / Reversible Rotation
Single Voltage / Reversible Rotation
Single Voltage / Single Rotation
Single Voltage / Single Rotation
INDUSTRIAL POWER SUPPLY
Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com