general purpose motors, single phase, rolled steel ... filemotor mechanical d at a ... ** 56h nema...

7
No.: Date: 6/16/2011 TECHNICAL PROPOSAL General Purpose Motors, Single Phase, Rolled Steel, Standard Efficiency, ODP Customer : Product line : Single-Phase : NEMA 48 & 56 ODP Catalog Number : 00718OS1CCD215T List Price : $961 Notes: Single-Phase :NEMA 48 & 5 ODP 6 Performed by: Checked: INDUSTRIAL POWER SUPPLY Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209 Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com

Upload: doandat

Post on 21-Sep-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

No.:

Date: 6/16/2011

TECHNICAL PROPOSAL

General Purpose Motors, Single Phase,Rolled Steel, Standard Efficiency, ODP

Customer :

Product line : Single-Phase : NEMA 48 & 56 ODP

Catalog Number : 00718OS1CCD215TList Price : $961

Notes:Single-Phase : NEMA 48 & 5 ODP6

Performed by: Checked:

INDUSTRIAL POWER SUPPLY

Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com

No.:

Date: 6/16/2011

DATA SHEETGeneral Purpose Motors, Single Phase, Rolled Steel, Standard E�ciency, ODP

Customer :Product line : De�nite Purpose : Single-Phase - ODP

: 7.5 HP: 1800 RPM: 215T: 1.15: 30.6 A: 19.66 in: 230-460V: 1: ODP: Foot Mount: Standard: Squirrel cage rotor: CE, UL, CSA: RAL 7022 – Dark Gray: Yes: B: Ball bearings: Continuous Duty S1: 40 ºC: 3300 ft (1000 m): IP21: 85 %: Rolled Steel: 60 Hz: F1 mounting T-Box: Stainless steel nameplate AISI 316 with laser etching: Enamel alkyd resin base: 1045 carbon steel shaft: B: NEMA: NPT threaded terminal box: Automatic drain plugs: V-ring slingers on both endshields: 4: H: 130 lbs

Notes:

Performed by: Checked:

INDUSTRIAL POWER SUPPLY

Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com

HP RPM Frame Service FactorFL Amps @ High'C' DimensionVoltagePhasesEnclosure BaseE�ciency RatingRotorCerti�cationsColorStart CapacitorInsulation ClassBearingsDutyAmbient TemperatureAltitudeDegree of ProtectionFL E�ciencyFrame MaterialFrequencyMounting NameplatePaintShaftTemperature Rise ClassDimensionsTerminal BoxDrain PlugsV-ring SlingersPolesImpregnation resin insulation classApprox. Shipping Weight

Data subject to change without notice. B-45

MO

TOR

MEC

HA

NIC

AL

DAT

A

GENERAL PURPOSE MOTORS – NEMA 48 & 56 ODP

MECHANICAL DATA

NEMAFRAME

MOUNTINGA B C D O P XO

KEY WAY SHAFT EXTENSION BEARINGS

2E 2F BA S R ES N-W U D.E. O.D.E.

B484,236 2,748 2,500 6,141 3,543

9,4093,000 5,905

5,748 1,516

* * * 1,500 0.5000

6203-ZZ 6202-ZZC48 10,197

56

4,875

3,000

2,750 6,535

4,015

9,764

3,500

6,378

0.187 0.517 1,102 1,874 0.6250

C56 10,551

A56 10,315

6,772 6,535 6204-ZZ 6203-ZZ

B56 11,1021,516

D56 12,283

F56H 3,0006,496

13,4641,300

G56H 5000** 13,858

“C” FLANGE DIMENSIONS

FLANGE AJ AK BDBF

AHNUMBER TAP

SIZE

FC-95 3,748 3,000 5,6294

UNC1/4” 1,689

FC-149 5,874 4,500 6,496 UNC3/8” 2,063

* THE SHAFT OF NEMA 48 FRAME MOTORS SHOWS A FLAT CHANFER WITH 0.291” OF WIDTH INSTEAD OFF THE KEYWAY.

** 56H NEMA IS PROVIDED WITH A DOUBLE HOLED BASE - DIMENSION B: 3” AND 5”.

Data subject to change without notice. www.weg.netB-58

MO

TOR

TECHN

ICAL D

ATA

Data subject to change without notice.

MECHANICAL DATA

GENERAL PURPOSE SINGLE PHASE MOTORS – ODPNEMA “T”

GENERAL PURPOSE SINGLE PHASE MOTORS –TEFCNEMA “T”

NEMAFRAMES

MOUNTINGA B C D G J K O P T

KEYWAY SHAFT EXTENSION AB AA D1

BEARINGS

2E 2F H BA S R ES N-W U D.E. O.D.E.

W182/4T7.500

4.500

0.406

2.7508.661 6.968

17.2444.500 0.630 1.890

2.4418.267

7.800

1.772

0.250 0.984 1.968 2.750 1.1257.362

NPT 1” A 4

6206-ZZ

6206-ZZ

5.500184T 5.500

3.500

17.050 1.968 8.820 7.835 6307-ZZ

W213/5T

8.500

5.500

9.765 8.87521.000

5.250 0.830 2.0003.343

9.6108.820

0.313 1.203 2.480

3.375

1.3757.953

6308-ZZ7.000

W213/5TZ 5.500 0.250 0.986 1.968 1.125

7.000215T 2.75019.567 2.165 10.630

0.313 1.203 2.480 1.3759.055

215TZ 3.500 0.250 0.986 1.968 1.125

2E 2F H BA S R ES N-W U D.E. O.D.E.

182T 4.500 5.905 14.448

184T 5.500 6.889 14.8706205-ZZ7.925 NPT1" A4 6206-ZZ0.984 1.771 2.750 1.1259.382 8.968 1.772 0.250

d1BEARINGS

7.500 0.406 2.750 8.653 4.500 0.500 1.929 1.850

KEYWAY SHAFT EXTENSIONAB AAK O P TC D G JNEMA

FRAMES

MOUNTINGA B

Data subject to change without notice. www.weg.netB-2

MO

TOR

ELECTRICAL D

ATA

Data subject to change without notice.

GENERAL PURPOSE MOTORS NEMA 48 & 56ODP – SINGLE PHASE

The values shown are subject to change without prior notice. To obtain guaranteed values, please contact our nearest sales offi ce.

ELECTRICAL DATA

RATED OUTPUT NEMA

FRAME

RATEDSPEED

FULL LOADCURRENT

INA

KLOCKEDROTOR

CURRENTKVA

CODE

FULLLOAD

TORQUETN

LB.FT

LOCKEDROTOR

TORQUETL / TN

BREAK-DOWN

TORQUETB / TN

EFFICIENCY% OF FULL LOAD

POWER FACTOR% OF FULL LOAD SERVICE

FACTORSF

MOMENTOF INERTIA

WK2LB.FT2

APPROX.WEIGHT

HP KW RPM AT 115 V

AT 230 V 50 75 100 50 75 100 LB

0.12 0.09 B48 1750 3.20 1.60 P 0.36 3.4 3.2 33.0 41.0 48.1 0.40 0.46 0.52 1.40 0.02420 17

0.16 0.12B48 3440 3.10 1.55 M 0.24 3.6 3.0 37.0 43.0 49.9 0.55 0.60 0.69 1.35 0.01281 16B48 1740 3.70 1.85 N 0.48 3.6 2.9 38.0 46.5 50.3 0.41 0.48 0.55 1.35 0.02800 18

0.25 0.18B48 3440 4.30 2.15 M 0.38 3.5 2.8 42.0 50.5 54.7 0.56 0.64 0.68 1.35 0.01495 18B48 1740 5.30 2.65 N 0.74 3.2 2.6 40.5 48.5 55.9 0.40 0.48 0.54 1.35 0.03204 20

0.33 0.25C48 3480 5.70 2.85 N 0.49 3.8 3.0 46.5 54.1 57.6 0.49 0.59 0.65 1.35 0.01898 21C48 1745 6.60 3.30 N 0.98 3.5 2.8 45.5 53.5 58.2 0.39 0.47 0.55 1.35 0.04010 21

0.5 0.37C48 3470 7.20 3.60 L 0.75 3.8 3.0 53.5 60.7 64.4 0.52 0.61 0.69 1.25 0.02326 23C48 1730 8.50 4.25 M 1.50 3.3 2.4 53.0 59.0 61.7 0.43 0.52 0.61 1.25 0.04817 24

0.75 0.55B56 3525 10.5 5.25 L 1.10 2.5 2.8 56.5 64.2 67.2 0.52 0.61 0.68 1.25 0.03322 28D56 1745 12.0 6.00 M 2.23 2.7 2.6 57.7 65.9 66.7 0.41 0.51 0.60 1.25 0.10702 31

1 0.75D56 3520 13.6 6.80 M 1.47 2.8 2.9 54.5 62.1 66.3 0.53 0.63 0.71 1.25 0.04153 33D56 1740 14.0 7.00 L 2.98 2.7 2.6 64.2 70.0 71.4 0.44 0.56 0.64 1.15 0.13384 35

1.5 1.1D56 3500 17.8 8.90 L 2.22 2.5 2.4 61.5 67.5 70.0 0.58 0.69 0.77 1.15 0.04983 38

F56H 1740 20.4 10.2 L 4.47 2.8 2.5 65.5 71.1 71.3 0.46 0.57 0.66 1.15 0.19554 42

2 1.5F56H 3525 21.9 11.0 M 2.94 2.5 2.8 71.1 76.2 77.9 0.59 0.67 0.75 1.15 0.06644 49G56H 1730 28.0 14.0 L 5.99 2.5 2.5 64.3 70.6 71.4 0.42 0.53 0.64 1.00 0.23018 48

3 2.2 G56H 3490 31.0 15.5 K 4.45 2.3 2.4 74.9 77.8 77.4 0.61 0.73 0.80 1.00 0.07214 44

GENERAL PURPOSE MOTORS – NEMA 56TEFC – SINGLE PHASE

RATED OUTPUT NEMA

FRAME

RATEDSPEED

FULL LOADCURRENT

IN A

LOCKEDROTOR

CURRENTKVA

CODE

FULLLOAD

TORQUETN

LB.FT

LOCKEDROTOR

TORQUETL / TN

BREAK-DOWN

TORQUETB / TN

EFFICIENCY% OF FULL LOAD

POWER FACTOR% OF FULL LOAD

SERVICEFACTOR

SF

MOMENTOF INERTIA

WK2LB.FT2

APPROX.WEIGHT

LBHP KW RPM AT

115 VAT

230 V 50 75 100 50 75 100

0.25 0.18B56 3480 4.60 2.30 N 0.37 2.8 2.9 36.0 45.0 50.0 0.56 0.64 0.70 1.15 0.02373 22

B56 1750 4.70 2.35 P 0.74 3.6 2.8 45.0 53.0 57.7 0.41 0.50 0.58 1.15 0.05363 20

0.33 0.25B56 3490 5.70 2.85 N 0.49 3.7 3.2 40.0 49.0 53.0 0.56 0.64 0.70 1.15 0.02776 22

B56 1750 5.60 2.80 N 0.98 3.4 2.8 49.0 58.0 61.0 0.44 0.53 0.62 1.15 0.06241 22

0.5 0.37

B56 3480 7.60 3.80 L 0.74 3.2 2.8 45.0 52.0 58.0 0.56 0.66 0.73 1.15 0.03156 23

B56 1750 7.40 3.70 L 1.48 2.9 2.7 56.0 64.0 66.5 0.46 0.57 0.65 1.15 0.08044 25

D56 1180 7.20 3.60 L 2.20 2.5 3.0 58.0 67.0 71.0 0.47 0.55 0.63 1.15 0.14285 38

0.75 0.55

B56 3490 10.4 5.20 M 1.11 3.0 2.9 52.0 60.0 64.0 0.54 0.64 0.72 1.15 0.03963 26

B56 1745 10.6 5.30 M 2.23 3.0 2.5 58.5 66.0 68.5 0.47 0.58 0.66 1.15 0.09824 28

F56H 1170 10.0 5.00 K 3.32 2.3 2.6 59.0 67.0 71.0 0.49 0.59 0.68 1.15 0.17774 42

1 0.75

D56 3500 12.8 6.40 M 1.48 3.2 2.8 55.0 63.0 67.0 0.56 0.67 0.75 1.15 0.05149 32

D56 1750 14.0 7.00 M 2.96 3.2 2.7 60.0 67.0 70.3 0.45 0.56 0.65 1.15 0.13384 34

G56H 1150 11.0 5.50 J 4.51 2.4 2.2 64.0 69.0 73.0 0.63 0.72 0.80 1.15 0.21333 49

1.5 1.1D56* 3480 17.1 8.55 K 2.23 2.5 2.5 62.0 69.0 70.0 0.61 0.72 0.80 1.15 0.05933 35

F56H 1750 17.4 8.70 K 4.44 2.8 2.6 70.0 75.0 76.5 0.52 0.64 0.72 1.15 0.19554 47

2 1.5F56H 3480 20.0 10.0 K 2.98 2.7 2.4 69.0 73.0 74.0 0.72 0.81 0.87 1.15 0.07902 44

G56H 1750 21.0 10.5 K 5.92 2.8 2.5 74.0 78.0 78.1 0.60 0.71 0.78 1.15 0.21333 50

3 2.2 G56H* 3480 26.0 13.0 J 4.47 2.5 2.5 75.0 79.0 80.0 0.82 0.90 0.93 1.15 0.09492 51

* DT = 105K

B-13Data subject to change without notice.

MO

TOR

ELEC

TRIC

AL

DAT

A

GENERAL PURPOSE MOTORS – NEMA “ T”ODP – SINGLE PHASE

ELECTRICAL DATA

GENERAL PURPOSE MOTORS – NEMA “ T”TEFC – SINGLE PHASE

RATED OUTPUT

NEMAFRAME

RATED SPEED

FULL LOAD CURRENT

IN A

LOCKED ROTOR

CURRENT KVA

CODE

FULL LOAD

TORQUE TN

LB.FT

LOCKED ROTOR

TORQUE TL / TN

BREAK-DOWN

TORQUE TB / TN

EFFICIENCY POWER FACTOR

SERVICE FACTOR

SF

MOMENT OF INERTIA

WK2 LB.FT2

APPROX. WEIGHT

% OF FULL LOAD

HP KW RPMAT

115 V

AT 230

V50 75 100 50 75 100 LB

0.5 0.37 143T 3530 7.60 3.80 N 0.73 2.7 2.4 50.0 56.0 60.0 0.56 0.65 0.71 1.15 0.02373 42

1 0.75143T 3510 12.6 6.30 L 1.48 2.4 2.4 57.0 63.0 67.0 0.62 0.71 0.77 1.15 0.03560 46143T 1760 11.2 5.60 L 2.94 2.8 2.7 65.0 72.0 74.0 0.61 0.71 0.79 1.15 0.09255 54

1.5 1.1143T 3535 15.2 7.60 K 2.20 2.4 2.8 68.0 73.5 76.0 0.70 0.81 0.85 1.15 0.04746 53145T 1760 14.4 7.20 L 4.42 2.5 2.9 65.0 72.0 76.0 0.76 0.82 0.87 1.15 0.12340 62182T 1180 19.0 9.50 K 6.59 2.2 2.6 60.0 68.0 72.0 0.53 0.62 0.70 1.15 0.34575 88

2 1.5145T 3530 19.2 9.60 J 2.94 2.7 2.8 72.0 75.5 79.0 0.74 0.84 0.86 1.15 0.05695 55145T 1740 19.0 9.50 J 5.96 2.3 2.3 69.0 74.0 76.0 0.75 0.85 0.90 1.15 0.19933 64213T 1160 20.0 10.0 K 8.93 2.4 2.3 68.0 75.0 80.0 0.68 0.75 0.80 1.15 0.53155 118

3 2.2

145T 3500 26.8 13.4 J 4.44 2.3 2.5 75.0 79.0 79.5 0.81 0.86 0.90 1.15 0.08068 60182T 3490 27.0 13.5 J 4.45 2.6 2.6 75.0 77.0 78.0 0.84 0.88 0.91 1.15 0.15187 87184T 1745 26.6 13.3 J 8.91 3.0 2.6 70.0 75.0 78.0 0.82 0.89 0.92 1.15 0.31561 89

W182/4T 1750 28.0 14.0 J 8.88 2.9 2.4 75.0 79.0 80.0 0.70 0.80 0.85 1.15 0.23730 88215T 1165 26.0 13.0 G 13.3 2.3 2.2 71.0 78.0 82.0 0.84 0.89 0.90 1.15 0.61935 162

5 3.7

184T 3500 42.0 21.0 H 7.40 2.8 2.6 79.0 81.0 83.0 0.80 0.88 0.92 1.15 0.19530 102184T 1730 42.0 21.0 H 15.0 2.9 2.4 75.0 78.0 80.0 0.86 0.92 0.95 1.15 0.42714 113

215TZ 1730 42.0 21.0 H 15.0 2.9 2.4 75.0 78.0 80.0 0.86 0.92 0.95 1.15 0.44375 128215T 1160 44.0 22.0 H 22.3 2.3 2.3 76.0 81.0 82.0 0.80 0.86 0.88 1.15 1.78450 166

7.5 5.5

184T 3495 61.8 30.9 H 11.1 2.8 2.6 79.0 83.0 84.0 0.82 0.89 0.92 1.15 0.57664 110213T 3495 61.8 30.9 H 11.1 2.8 2.6 79.0 83.0 84.0 0.82 0.89 0.92 1.15 0.57664 110

215TZ 1735 68.0 34.0 H 22.4 3.2 2.5 75.0 80.0 82.0 0.71 0.81 0.86 1.15 0.90649 161215T 1735 68.0 34.0 H 22.4 3.2 2.5 75.0 80.0 82.0 0.71 0.81 0.86 1.15 0.90649 157

10 7.5215T 3520 79.6 39.8 H 14.7 2.1 2.6 81.5 85.1 86.2 0.91 0.93 0.95 1.15 0.57664 157215T 1720 80.0 40.0 G 30.1 2.7 2.2 78.0 82.0 83.0 0.93 0.96 0.97 1.15 1.18650 180

12.5 9.2215T 3520 94.6 47.3 H 18.4 1.6 2.9 86.0 87.5 89.0 0.91 0.93 0.95 1.15 0.75699 176215T* 1730 95.6 47.8 G 37.4 2.2 2.4 79.0 84.0 85.3 0.95 0.96 0.98 1.15 1.33363 192

* DT 105K

OUTPUT RATED SPEED (RPM)

FRAMEFULL

AT 230V

FULL LOAD TORQUE (FT.LB)

LOCKED ROTOR

CURRENTLOCKED ROTOR

TORQUE TL/TN

BREAK-DOWN

TORQUE TB/TN

EFFICIENCY POWER FACTOR

SERVICE FACTOR

SF

INERCIA J (SQ.FT.LB)

ALLOWABLE LOCKED

ROTOR TIME (S)

WEIGHT (LB)

% OF FULL LOAD

HP KWCODE

IL/IN 50 75 100 50 75 100

HOT COLD

3 2.2182T 3520 15 4.42 J 6.4 2.3 2.6 78 81 81.5 0 0.71 0.79 1.25 0.18035 6 13 85.7

184T 1750 17.5 8.88 K 6.5 2.1 2 71 74 75 0.56 0.68 0.75 1.25 0.43189 6 13 106

5 3.7184T 3500 21 7.4 G 6.5 2.6 2 80 81.5 81.5 0.85 0.91 0.92 1.25 0.25628 6 13 102

184T 1745 21.5 14.8 H 6.5 2.2 2 81.5 82.5 82.5 0.82 0.87 0.91 1.25 0.49833 6 13 115

7.5 5.5 184T 3510 30 11.1 H 7.2 2.4 2.3 82 84 85 0.9 0.93 0.95 1.25 0.29425 6 13 112

Typical Wiring Diagrams - Single-Phase MotorsAlways use wiring diagram supplied on motor nameplate.

Dual Voltage / Reversible Rotation

With Thermal Overload Protection

Dual Voltage / Single Rotation

Without Thermal Overload Protection

Dual Voltage / Reversible Rotation Dual Voltage / Single Rotation

Single Voltage / Reversible Rotation

Single Voltage / Reversible Rotation

Single Voltage / Single Rotation

Single Voltage / Single Rotation

INDUSTRIAL POWER SUPPLY

Headquarters: Fremont, CA USA | International: (510) 490-2187 | Inside USA: 877-474-8209Fax: (510) 490-1507 | Visit us on the web at www.temcoindustrialpower.com