general catalog 09/10
DESCRIPTION
General Catalog 2009/2010TRANSCRIPT
GeneralCatalogue
2010
Multiswitches
Amplifi ers
Field meters
Headends
Accessories
01
31
37
43
57
01
Stand-alone multiswitches (SEM series) .......................... 02Stand-alone multiswitches (OLS series) .......................... 05Cascade multiswitches (KAS series) ............................... 07Cascade multiswitches (OLY series) .............................. 10Cascade multiswitches (KAD series) .............................. 15Cascade multiswitches (DK series) ................................. 19UnicableTM multiswitches (UCS series) ............................ 22Multisplitters (ASV series) ............................................... 26Multitaps (MT series) ...................................................... 27Conditional Access multiswitches (ANCASY® series) ..... 28
multiswitches
multiswitches
Reference SEM 5x4 N SEM 5x6 N SEM 5x8 N SEM 5x12 N SEM 5x16 N SEM 5x24 N SEM 5x32 N
Code 01249.11 01279.11 01289.11 01297.11 01298.11 01280.11 01281.11
SAT inputs / TER inputs 4 / 1 4 / 1 4 / 1 4 / 1 4 / 1 4 / 1 4 / 1
Receiver outputs 4 6 8 12 16 24 32
Band frequencies(MHz)
47 - 862 /5 - 862**
47 - 862 /5 - 862**
47 - 862 /5 - 862**
47 - 862 /5 - 862**
47 - 862 /5 - 862**
80 - 862 /5 - 862**
80 - 862 /5 - 862**
Loss (dB) 0 ± 2 / 18 0 ± 2 / 20 0 ± 2 / 21 0 ± 2 / 23 0 ± 2 / 24 1 ± 2 / 30 ± 2 0 ± 1 / 30 ± 2
Output level(60 dB IMA3)(1) (dBμV)
95 95 95 95 95 90 90
Isolation (dB) >20 >20 >20 >20 >20 >20 >20
Band frequencies(MHz)
950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400
Loss (dB) 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2
Output level(35 dB IMA3) (2) (dBμV)
105 105 105 95 95 95 95
Isolation (dB) >20 >20 >20 >20 >20 >20 >20
Maximum supplycurrent 12/18 V (mA)
500 500 500 500 500 500 500
Power supply 180-265VAC / 47-63Hz
180-265VAC / 47-63Hz
180-265VAC/ 47-63Hz
180-265VAC / 47-63 Hz
180-265VAC/ 47-63 Hz
180-265VAC/ 47-63 Hz
180-265VAC/ 47-63 Hz
Generator 22 KHz Yes Yes Yes Yes Yes Yes Yes
Dimensions (mm) 300x115x80 350x115x80 350x115x80 400x115x80 450x125x80 540x125x80 540x125x80
Weight (g) 730 860 880 1.000 1.150 1.340 1.380
02
5 IN Stand - alone multiswitchesSEM series
* The LNC is switched off if there is not any receiver working** Active/passive switch(1) DIN 45004 B(2) EN 50083-3
SEM SeriesStand - alone
Energy saving*
Active SAT / TER**
Terrestrial Push-Pull Input
Made in Germany
SEM 5x8 N SEM 5x32 N
multiswitches
03
* R.P. 5-30 available(1) DIN 45004 B(2) EN 50083-3
SEM SeriesStand - alone
Return PathEnergy savingActive SAT / TERTerrestrial Push-Pull InputMade in Germany
Reference SEM 9x4 N SEM 9x6 N SEM 9x8 N SEM 9x12 N SEM 9x16 N SEM 9x24 N SEM 9x32 N
Code 09004.11 09006.11 09008.11 09012.11 09016.11 09024.11 09032.11
SAT inputs / TER inputs 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1
Receiver outputs 4 6 8 12 16 24 32
Band frequencies* (MHz) 5 - 65 5 - 65 5 - 65 5 - 65 5 - 65 5 - 65 5 - 65
Loss (dB) 19 ± 2 20 ± 2 20 ± 2 23 ± 2 25 ± 2 28 ± 2 30 ± 2
Isolation (dB) >25 >25 >25 >25 >25 >25 >25
Band frequencies (MHz) 80 - 862 80 - 862 80 - 862 80 - 862 80 - 862 80 - 862 80 - 862
Loss (dB) 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2
Output level (60 dB IMA3)(1) (dBμV) 95 95 95 93 93 90 90
Isolation (dB)
TER / SAT (dB) >40 >40 >40 >40 >40 >40 >40
SAT / TER (dB) >40 >40 >40 >40 >40 >40 >40
REC / REC (dB) >25 >25 >25 >25 >25 >25 >25
Band frequencies (MHz) 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400
Loss (dB) 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2
H/V Isolation (dB) >25 >25 >25 >25 >25 >25 >25
SAT / SAT Input Isolation (dB) >40 >40 >40 >40 >40 >40 >40
REC / REC Isolation >30 >30 >30 >30 >30 >30 >30
Output level (35 dB IMA3)(2) (dBμV) 105 105 105 105 105 105 105
Current consumption receiver13/18 V (mA)
70 70 70 70 70 70 70
Power supply 180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
Maximum supply current12 / 18 V (mA)
500 / 700 500 / 700 500 / 700 500 / 700 500 / 700 500 / 700 500 / 700
Generator 22 KHz Yes Yes Yes Yes Yes Yes Yes
Dimensions (mm) 400x100x80 400x100x80 400x100x80 400x190x80 400x190x80 400x350x80 400x350x80
Weight (g) 1.060 1.070 1.080 1.600 1.600 1.650 1.700
9 IN Stand - alone multiswitchesSEM series
SEM 9x12 N SEM 9x32 N
multiswitches
17 IN Stand - alone multiswitchesSEM series
04
Reference SEM 17x8 N SEM 17x12 N SEM 17x16 N SEM 17x24 N SEM 17x32 N
Code 01732.11 01733.11 01734.11 01726.11 01727.11
SAT inputs / TER inputs 16 / 1 16 / 1 16 / 1 16 / 1 16 / 1
Receiver outputs 8 12 16 24 32
Band frequencies 5 - 65 5 - 65 5 - 65 5 - 65 5 - 65
Loss (dB) 20 ± 2 23 ± 2 25 ± 2 28 ± 2 30 ± 2
Band frequencies (MHz) 80 - 862 80 - 862 80 - 862 80 - 862 80 - 862
Loss (dB) 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2
Output level(60 dB IMA3)
(1) (dBμV)95 93 93 90 89
Isolation
TER / SAT (dB) >40 >40 >40 >40 >40
SAT / TER (dB) >40 >40 >40 >40 >40
REC / REC (dB) >25 >25 >22 >22 >22
Band frequencies (MHz) 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400
Loss (dB) 0 ± 2 0 ± 2 0 ± 2 0 ± 2 0 ± 2
SAT attenuator (dB) - 6 6 6 6
Input isolation
SAT / SAT (dB) >40 >40 >40 >40 >40
REC / REC (dB) >30 >30 >30 >30 >30
Output level(35 dB IMA3)
(2) (dBμV)105 105 105 105 105
Current consumption receiver 13/18V (mA)
100 100 100 100 100
Power supply 94 -265 VAC /47-63 Hz
94 -265 VAC /47-63 Hz
94 - 265 VAC /47-63 Hz
94 - 265 VAC /47-63 Hz
94 - 265 VAC /47-63 Hz
Maximum supply current13/18V (mA)
600 / 1.300 600 / 1.300 600 / 1.300 600 / 1.300 600 / 1.300
Dimensions (mm) 540x110x 80 540x190x 80 540x190x 80 540x350x 80 540x350x 80
Weight (g) 1.940 2.880 3.060 3.550 3.630
(1) DIN 45004 B(2) EN 50083-3
SEM SeriesStand - alone
Return PathActive SAT / TERTerrestrial Push-Pull InputIndicator of Selected InputMade in Germany
SEM 17x32 NSEM 17x16 N
multiswitches
Reference OLS 9x4 N OLS 9x6 N OLS 9x8 N OLS 9x12 N OLS 9x16 N
Code 02904.11 02906.11 02908.11 02912.11 02916.11
SAT inputs / TER inputs 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1
Receiver outputs 4 6 8 12 16
Band frequencies (MHz) 5 - 862 5 - 862 5 - 862 5 - 862 5 - 862
Loss (dB) 14±2 20±2 20±2 23±2 25±2
Band frequencies (MHz) 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400
Loss (dB) 0±2 0±2 0±2 0±2 0±2
Output level (35 dB IMA3)(1) (dBμV) 105 105 105 105 105
Current consumption receiver 13V/18V (mA) 70 70 70 70 70
Power supply 180 - 265 VAC /47 - 65 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
180 - 265 VAC /47 - 63 Hz
Maximum supply current 18 V (mA) 700 700 700 700 700
Dimensions (mm) 400x100x80 400x100x80 400x100x80 400x190x80 400x190x80
Weight (g) 1.050 1.070 1.080 1.600 1.600
05
Return PathActive SATMade in Germany
Reference OLS 5x4 N OLS 5x6 N OLS 5x8 N OLS 5x12 N OLS 5x16 N
Code 02504.11 02506.11 02508.11 02512.11 02516.11
SAT inputs / TER inputs 4 / 1 4 / 1 4 / 1 4 / 1 4 / 1
Receiver outputs 4 6 8 12 16
Band frequencies (MHz) 5 - 862 5 - 862 5 - 862 5 - 862 5 - 862
Loss (dB) 18 20 21 23 24
Band frequencies (MHz) 950 - 2400 950 - 2400 950 - 2400 950 - 2400 950 - 2400
Loss (dB) 0±2 0±2 0±2 0±2 0±2
Output level (35 dB IMA3)(1) (dBμV) 105 105 105 95 95
Maximum supply current 18 V (mA) 700 700 700 700 700
Power supply 180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
Dimensions (mm) 230x110x65 230x110x65 230x110x65 325x115x65 325x115x65
Weight (g) 840 850 870 1.380 1.550
5 IN Stand - alone multiswitchesOLS series
(1) EN 50083-3
(1) EN 50083-3
9 IN Stand - alone multiswitchesOLS series
OLS SeriesStand - alone
OLS 5x16 N
OLS 9x16 N
multiswitches
06
Reference OLS 17x8 N OLS 17x12 N OLS 17x16 N
Code 02708.11 02712.11 02716.11
Inputs / Outputs 17/8 17/12 17/16
Band frequencies (MHz) 5 - 862 5 - 862 5 - 862
Loss (dB) 21±2 23±2 24±2
Band frequencies (MHz) 950 - 2400 950 - 2400 950 - 2400
Loss (dB) 0±2 0±2 0±2
Output level (35 dB IMA3)(1) (dBμV) 105 105 105
Maximum supply current 18 V (mA) 1.200 1.200 1.200
Power supply 180-265 VAC / 47-63 Hz 180-265 VAC / 47-63 Hz 180-265 VAC / 47-63 Hz
Dimensions (mm) 540x110x80 540x110x80 540x110x80
Weight (g) 1.940 2.880 3.060
17 IN Stand - alone passive multiswitchesOLS series
(1) EN 50083-3
Return PathActive SATMade in Germany
OLS SeriesStand - alone
OLS 17x16 N
multiswitches
07
Reference KAS 5x6 K KAS 5x8 K
Code 01470.11 01471.11
Trunk inputs / outputs 5 / 5 5 / 5
Receiver outputs 6 8
Band frequencies (MHz) 5 - 862 5 - 862
Attenuation trunk (dB) 4-5 4-5
Tap loss (dB) 24±2 25±2
Band frequencies (MHz) 950 - 2400 950 - 2400
Attenuation trunk (dB) 3-5 3-5
Tap loss (dB) 5±2 5±2
Output level (35 dB IMA3)(1) (dBμV) 500 500
Isolation REC / REC (dB) > 30 > 30
Maximum supply current 12 / 18 V (mA) 100 100
Power supply 180 - 265 VAC / 47 - 63 Hz 180 - 265 VAC / 47 - 63 Hz
Generator 22 KHz Yes Yes
Dimensions (mm) 230x110x60 230x110x60
Weight (g) 710 720
5 IN cascade headend multiswitchesKAS series
(1) EN 50083-3
Return PathActive SATMade in Germany
KAS SeriesCascade
The 5-line cascadeable system distributes up to 4 SAT-IF polarisations and the complete terrestrialfrequencies to multiple subscribers.
In case of high signal-level from the LNC and short distance from the dish to the multiswitch, a mul-tiswitch with power supply (KAS 5x6/8 K) can be used as head component. Due to the low through-loss and the low distribution loss small systems mostly work without any additional amplifi er.
The SAT-IF in-and outputs are DC-coupled. Out of this reason the multiswitch wich supplies the LNC can be installed at any place within the system. This opens up a variety of system confi gurations. The level can be increased within the trunk line by using a line am-plifi er. There is a permanent supply of the terrestrial signal even when all receivers are switched off.
KAS 5x8 K
multiswitches
08
Reference KAS 5x4 KAS 5x6 KAS 5x8
Code 01474.11 01476.11 01478.11
Trunk inputs / outputs 5 / 5 5 / 5 5 / 5
Receiver outputs 4 6 8
Band frequencies (MHz) 5-862 5-862 5-862
Attenuation trunk (dB) 4-5 4-5 4-5
Tap loss (dB) 23±2 24±2 25±2
Decoupling REC / REC (dB) 25 25 25
Band frequencies (MHz) 950-2400 950-2400 950-2400
Attenuation trunk (dB) 3-5 3-5 3-5
Tap loss (dB) 5±2 5±2 5±2
Output level (35 dB IMA3)(1) (dBμV) 100 100 100
Decoupling REC / REC (dB) >30 >30 >30
Dimensions (mm) 130x110x60 130x110x60 130x110x60
Weight (g) 440 450 460
5 IN cascade multiswitchesKAS series
(1) EN 50083-3
KAS SeriesCascade
Return Path
Active SAT
Made in Germany
KAS 5x6
2
2
DC
2
DC
No DC
2
2
multiswitches
09
Reference KAS 20 NV KAS 20 VV
Code 01477.11 01469.11
Inputs SAT / TER 4 / 1 4 / 1
Trunk outputs TER + SAT 5 5
Band frequencies (MHz) R.P. Switchable 5-30 / 5-65 5-30 / 5-65
Active mode gain (dB) 13±2 -
Passive mode loss (dB) 3±2 -
Attenuator (dB) 20 -
Max. output level (60 dB IMA3)(1) (dBμV) 116 -
Band frequencies (MHz) 47-862 / 80-862 5-862
Active mode gain (dB)* 19-22 -
Passive mode loss (dB)* 3±2 1±1
Attenuator (dB) 20 -
Line equalizer (dB/MHz) 14 / 47-80 -
Trunk isolation TER / SAT (dB) >40 >40
Trunk isolation SAT / TER (dB) >40 >40
Max. output level (60 dB IMA3) (dBμV) 112 -
Band frequencies (MHz) 950-2400 950-2400
Gain (dB) 18-22 18-22
Level tuning (dB) 6 -
Line equalizer (dB/MHz) 14 / 47-80 -
Trunk isolation SAT / SAT (dB) >30 >30
Max. output level (35 dB IMA3)(2) (dBμV) 112 112
Maximum supply current 13 / 18 V (mA) -- 350 / 500
Power supply 94-265 VAC / 50-60 Hz 94-265 VAC / 50-60 Hz
Dimensions (mm) 310x110x80 310x110x80
Trunk amplifi ersKAS series
* Active / passive switch(1) DIN 45004 B(2) EN 50083-3
KAS SeriesAmplifi ers
Return Path switchable AttenuatorLine equalizerTER amplifi er switchableMade in Germany
KAS 20 NV
multiswitches
Reference OLY 9x4 K OLY 9x8 K OLY 9x12 K OLY 9x16 K
Code 01500.11 01502.11 01510.11 01511.11
Inputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1
Trunk outputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1
Receiver outputs 4 8 12 16
Band frequencies (MHz) 5-862 5-862 5-862 5-862
Loss (dB) 21±2 23±2 25±2 25±2
Trunk loss (dB) 4-6 4-6 4-6 4-6
Trunk isolation SAT / TER (dB) >40 >40 >40 >40
Isolation REC / REC (dB) >25 >25 >25 >25
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400
Loss (dB) 6±2 6±2 6±2 6±2
Trunk loss (dB) 2-4 2-4 2-6 3-6
H/V isolation (dB) >25 >25 >25 >25
Trunk isolation SAT / SAT (dB) >40 >40 >40 >40
Max. output level (35 dB IMA3) (dBμV) 102 102 102 102
Current consumption receiver13 V / 18 V (mA)
50 / 70 50 / 70 50 / 70 50 / 70
Maximum supply current 12 / 18 V (mA) 350 / 700 350 / 700 350 / 700 350 / 700
Power supply 180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
180-265 VAC /47-63 Hz
Dimensions (mm) 400x100x80 400x100x80 400x190x80 400x190x80
Weight (g) 1.070 1.100 1.600 1.620
10
9 IN cascade head multiswitchesOLY series
OLY SeriesCascade
Return PathActive SATMade in Germany
OLY 9x16 K
multiswitches
11
Reference OLY 9x4 OLY 9x8 OLY 9x12 OLY 9x16
Code 01503.11 01504.11 01508.11 01509.11
Inputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1
Trunk outputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1
Receiver outputs 4 8 12 16
Band frequencies (MHz) 5-862 5-862 5-862 5-862
Loss (dB) 21±2 23±2 24±2 25±2
Trunk loss (dB) 4 5 6 7
Trunk isolation SAT / TER (dB) >40 >40 >40 >40
Isolation REC / REC (dB) >25 >25 >25 >25
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400
Loss (dB) 6±2 6±2 6±2 6±2
Trunk loss (dB) 2-3 2-4 2-6 2-6
H/V isolation (dB) >25 >25 >25 >25
Trunk isolation SAT / SAT (dB) >40 >40 >40 >40
Max. output level (35 dB IMA3)(1) (dBμV) 102 102 102 102
Current consumption receiver13 V / 18 V
50 / 70 50 / 70 50 / 70 50 / 70
Dimensions (mm) 280x110x80 280x110x80 280x190x80 280x190x80
Weight (g) 780 860 1.380 1.390
9 IN cascade multiswitchesOLY series
(1) EN 50083-3
OLY SeriesCascade
Return PathActive SATMade in Germany
OLY 9x8
12
multiswitches
Reference OLY D9 KV PLU 9E PLU 9A
Code 01507.11 05506.11 05507.11
Band frequencies (MHz) -- 5-862 --
Gain (dB) -- -1 --
Band frequencies (MHz) -- -- 5-65
Gain (dB) -- -- 12
Max. output level (60 dB IMA3)(1) (dBμV) -- -- 116
Band frequencies (MHz) -- -- 87-862
Gain (dB) -- -- 15-18
Max. output level (60 dB IMA3)(1) (dBμV) -- -- 100
Band frequencies (MHz) 47-862 -- --
Gain (dB) 19-22 -- --
Band frequencies (MHz) 950-2400 950-2400 950-2400
Gain (dB) 18-22 8-12 12-16
Max. output level (35 dB IMA3)(2) (dBμV) 110 110 108
Power supply (47-63 Hz) 180-265 VAC 94-265 VAC 94-265 VAC
Dimensions (mm) 330x115x65 -- --
Weight (g) 1.100 1.800 1.900
Trunk amplifi ersOLY series
(1) DIN 45004 B(2) EN 50083-3
OLY SeriesTrunk amplifi ers
Made in Germany
OLY D9 KV
PLU 9E PLU 9A
13
multiswitches
Reference OLY 17x8 K OLY 17x12 K OLY 17x16 K OLY 17x24 K OLY 17x32 K
Code 02750.11 02751.11 02752.11 02753.11 02754.11
Inputs SAT / TER 16 / 1 16 / 1 16 / 1 16 / 1 16 / 1
Trunk outputs SAT / TER 16 / 1 16 / 1 16 / 1 16 / 1 16 / 1
Receiver outputs 8 12 16 24 24
Band frequencies (MHz) 5-862 5-862 5-862 5-862 5-862
Loss (dB) 25±2 27±2 28±2 31±2 33±2
Trunk loss (dB) 3-5 4-6 4-6 4-6 4-6
Trunk isolation SAT / TER (dB) >40 >40 >40 >40 >40
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400 950-2400
Gain (dB) 0-5 0-5 0-5 1±2 1±2
Trunk loss (dB) 1-3 2-4 2-4 5-8 5-8
H/V isolation (dB) >25 >25 >25 >25 >25
Trunk isolation SAT / SAT (dB) >40 >40 >40 >40 >40
Max. output level (35 dB IMA3)(1) (dBμV) 100 100 100 100 100
Current consumption receiver 13 V / 18 V 100 100 100 100 100
Maximum supply current 18 V (mA) 1200 1200 1200 1200 1200
Power supply 180-265 VAC /50-60 Hz
180-265 VAC /50-60 Hz
180-265 VAC /50-60 Hz
180-265 VAC /50-60 Hz
180-265 VAC /50-60 Hz
Dimensions (mm) 540x110x80 540x190x80 540x190x80 540x350x80 540x350x80
Weight (g) 2.100 2.950 3.050 3.590 3.670
17 IN head multiswitchesOLY series
(1) EN 50083-3
OLY SeriesCascade
Return PathActive SATMade in Germany
OLY 17x16 K
14
multiswitches
Reference OLY 17x8 OLY 17x12 OLY 17x16 OLY 17x24 OLY 17x32
Code 02761.11 02762.11 02763.11 02764.11 02765.11
Inputs SAT / TER 16 / 1 16 / 1 16 / 1 16 / 1 16 / 1
Trunk outputs SAT / TER 16 / 1 16 / 1 16 / 1 16 / 1 16 / 1
Receiver outputs 8 12 16 24 32
Band frequencies (MHz) 5-862 5-862 5-862 5-862 5-862
Loss (dB) 25±2 27±2 28±2 31±2 33±2
Trunk loss (dB) 3-5 4-6 4-6 4-6 4-6
Trunk isolation SAT / TER (dB) >40 >40 >40 >40 >40
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400 950-2400
Gain (dB) 0-5 0-5 0-5 1±2 1±2
Trunk loss (dB) 1-3 2-4 2-4 5-8 5-8
H/V isolation (dB) >25 >25 >25 >25 >25
Trunk isolation SAT / SAT (dB) >40 >40 >40 >40 >40
Max. output level (35 dB IMA3)(1) (dBμV) 100 100 100 100 100
Current consumption receiver 13 V / 18 V 100 100 100 100 100
Dimensions (mm) 380x110x80 380x190x80 380x190x80 380x350x80 380x350x80
Weight (g) 1.760 2.650 2.750 3.220 3.300
17 IN cascade multiswitchesOLY series
(1) EN 50083-3
OLY SeriesCascade
Return PathActive SATMade in Germany
OLY 17x12
15
multiswitches
Reference KAD 9x8 K KAD 9x12 K KAD 9x16 K KAD 9x24 K KAD 9x32 K
Code 05771.11 05772.11 05773.11 05720.11 05721.11
Inputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1
Trunk outputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1
Receiver outputs 8 12 16 24 32
Band frequencies R.P. (MHz)* 5-65 5-65 5-65 5-65 5-65
Tap loss (dB) 28 28 30 31±2 33±2
Trunk loss (dB) 4 4 4 5 5
Band frequencies (MHz) 80-862 80-862 80-862 80-862 80-862
Loss (dB) 4±2 6±2 6±2 0±2 0±2
Attenuator (dB) 20 20 20 20 20
Trunk loss (dB) 4-6 4-6 4-6 4-6 4-6
Trunk isolation SAT / TER (dB) >40 >40 >40 - -
Max. output level (60 dB IMA3)(1) (dBμV) 92 92 90 85 84
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400 950-2400
Gain (dB) 1±2 1±2 1±2 1±2 1±2
Attenuator pos. B (dB) 10 10 10 10 10
Trunk loss (dB) 3-6 3-6 3-6 5-8 5-8
H/V isolation (dB) >25 >25 >25 >25 >25
Trunk isolation SAT / SAT (dB) >40 >40 >40 >40 >40
Max. output level (35 dB IMA3)(2) (dBμV) 102 102 102 102 102
Power supply 94-265 / 50-60 Hz 94-265 / 50-60 Hz 94-265 / 50-60 Hz 94-265 / 50-60 Hz 94-265 / 50-60 Hz
Maximum supply current 13 / 18 V (mA) 500 / 1.200 500 / 1.200 500 / 1.200 500 / 1.200 500 / 1.200
Generator 22 KHz Yes Yes Yes Yes Yes
Dimensions (mm) 400x190x80 400x190x80 400x190x80 400x350x80 400x350x80
Weight (g) 1.650 1.700 1.750 2.520 2.600
9 IN cascade head multiswitchesKAD series
* R.P. 5-30 available(1) DIN 45004 B(2) EN 50083-3
KAD SeriesCascade
Return PathActive SAT / TERTerrestrial Push - Pull inputMade in Germany
KAD 9x32 K
16
multiswitches
Reference KAD 9x8 KAD 9x12 KAD 9x16 KAD 9x24 KAD 9x32
Code 05778.11 05775.11 05779.11 05730.11 05731.11
Inputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1
Trunk outputs SAT / TER 8 / 1 8 / 1 8 / 1 8 / 1 8 / 1
Receiver outputs 8 12 16 24 32
Band frequencies R.P. (MHz)* 5-65 5-65 5-65 5-65 5-65
Tap loss (dB) 27 30 30 31±2 33±2
Trunk loss (dB) 4 4 4 5 5
Band frequencies (MHz) 80-862 80-862 80-862 80-862 80-862
Loss (dB) 5±2 5±2 6±2 0±2 0±2
Attenuator (dB) 20 20 20 20 20
Trunk loss (dB) 4-6 4-6 4-6 4-6 4-6
Trunk isolation SAT / TER (dB) >40 >40 >40 >40 >40
Max. output level (60 dB IMA3)(1) (dBμV) 95 92 90 85 84
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400 950-2400
Gain (dB) 1±2 1±2 1±2 1±2 1±2
Trunk loss (dB) 3-6 3-6 3-6 4-7 4-7
H/V isolation (dB) >25 >25 >25 >25 >25
Trunk isolation SAT / SAT (dB) >40 >40 >40 >40 >40
Max. output level (35 dB IMA3)(2) (dBμV) 102 102 102 102 102
Current consumption receiver13 / 18 V (mA)
40 / 70 40 / 70 40 / 70 40 / 70 40 / 70
Current consumption via terrestrialtrunk 13 V
200 200 200 250 250
Dimensions (mm) 240x100x80 240x190x80 240x190x80 240x350x80 240x350x80
Weight (g) 830 1.390 1.400 2.160 2.240
9 IN cascade multiswitchesKAD series
KAD SeriesCascade
* R.P. 5-30 available(1) DIN 45004 B(2) EN 50083-3
KAD 9x16
Return PathActive SAT / TERTerrestrial Push - Pull inputMade in Germany
17
multiswitches
Amplifi erKAD series
Reference KAD 22 V
Code 01688.11
Inputs SAT / TER 8 / 1
Trunk outputs SAT / TER 9
Band frequencies (MHz) R.P. switchable 5-30 / 5-65
Gain (dB) 13±2
Passive mode loss (dB) 3±2
Attenuator (dB) 20
Max. output level (60 dB IMA3)(1) (dBμV) 116
Band frequencies (MHz) 47-862 / 80-862
Active mode gain (dB)* 19-22
Passive mode loss (dB)* 3±2
Attenuator (dB) 20
Line equalizer (dB) 14 / 47-80
Trunk isolation SAT / TER (dB) >40
Max. output level (60 dB IMA3)(1) (dBμV) 112
Band frequencies (MHz) 950-2400
Gain (dB) 18-22
Attenuator (dB) 6
Line equalizer (dB) 10
Trunk isolation SAT / SAT (dB) >30
Max. output level (35 dB IMA3)(2) (dBμV) 112
Power supply 94-265 VAC / 50-60 Hz
Remote power supply for ter. trunk output 1.300 mA @ 13VDC
Dimensions (mm) 400x110x80
Weight (g) 1.200
* Active / passive switch(1) DIN 45004 B(2) EN 50083-3
KAD SeriesAmplifi er
Return Path switchableAttenuatorLine equalizerTER amplifi er switchableMade in Germany
KAD 22 V
18
multiswitches
DK SeriesExamples of application
POSITION INDICATOR SWITCH
The position indicator switch makes easier the installation of the device verifyingthe compatibility of the receiver with the multiswitch. Normally a receiver with DiSEqC carries the installation of 4 LNCs, this 4 LNCs usually correspond to fourdifferent satellites with their four corresponding bands. The eight first inputs of the multiswitch can be controlled by the means of Toneburst protocol analogicalsignal, the next 8 inputs can only be programmed by the means of DiSEqC.In order to verify the compatibility and make a correct installation we must followthe following steps:
1.- The system must be fed by and connected to LNCs.
2.- The satellite receiver must be connected to the output “Out 2” of the mul-tiswitch and it is advisable to connect a Tv to the receiver in order to verify the correct running of the system.
3.- The switch must be in “Mode 1”.
4.- If the receiver has DiSEqC, it will recognize the 4 LNCS by the means of DiSEqC command.
5.- In the display that the multiswitch incorporates it could be verified that the tuned band in the receiver corresponds to a fixed input, since it shows all the time the satellite input that the receiver is communicating to.
6.- Once the installation is finished, we must put the switch in the “Off” position.
This helping system in the installation allows the installer to identify in each cascade multiswitch all the cablesthat are in the input. It provides the correct position of the cable that we want to connect at any time, by the means of the display of the multiswtich. In order to make a correct use of this system you must follow the following steps:
1.- Verify the status of the power supply’s led of the headend cascade multiswitch. If the light of the LED is fix, the device is running correctly, if on the contrary it is flicking or the LED is off, it indicates that there is a short-circuit or that the feeding of the device is overloaded.
2.- Connect it to the headend cascade multiswitch output.
3.- Turn the small switch of the indicator of position to the position “Mode 2”.
4.- Try to connect the main cables that come from the headend one by one tothe multiswitch terrestrial signal input. The moment when a “0” appears in the display, it will show the terrestrial signal cable.
5.- Once the terrestrial signal cable is correctly connected, we have to select another downlink and connectit in the first multiswitch satellite input. The display will show which the correct input of the cable is.
6.- Repeating the last instruction until we have all the satellite signal cable connected. If during the process of installation, when connecting a cable the position of the display got erased, keep this cable aside and connect it once the remaining cables are fixed in their correct position.
7.- The process for installing the resting multiswitches of the installation is the same.
8.- In the case where we have to install a cascade line amplifier, it has to be placed just before the input or justafter the output, depending on the function (pre or post amplifier). Each single path of the amplifier allows thedirect current to go through, from the input to the output.
9.- The small connection cables between the amplifier and the multiswitch can not be crossed.
10.- If the display shows a mark after having fixed it correctly, it is possible that one of the cables has a short-circuit.
11.- In the last cascade multiswitch, the main outputs have to be ended with charges of 75 Ohms. If at the moment when the endings are connected a “0” appears, it will be necessary to check this output because it ispossible that it has a short-circuit.
12.- After completing the installation, we must fix all the switches of the multiswitch in the “Off” position.
WIZARD SYSTEM IN THE INSTALLATION (PATENTED)
DiSEqC receiver
Mode 1Installation testonly in Out 2
The display showsthe SAT input ofthe channel whereit is tuned
19
multiswitches
*Active / Passive switch(1) DIN 45004 B(2) EN 50083-3
Reference DK 17x8 K DK 17x12 K DK 17x16 K DK 17x24 K DK 17x32 K
Code 01717.11 01718.11 01719.11 01728.11 01729.11
Inputs SAT / TER 16/1 16/1 16/1 16/1 16/1
Trunk outputs SAT / TER 16/1 16/1 16/1 16/1 16/1
Receiver outputs 8 12 16 24 32
Band frequencies (MHz) 5-862 5-862 5-862 5-862 5-862
Terrestrial switch position Passive Passive Passive Passive Passive
Loss (dB) 25±2 27±2 28±2 31±2 33±2
Band frequencies (MHz)* 5-65 / 80-862 5-65 / 80-862 5-65 / 80-862 5-65 / 80-862 5-65 / 80-862
Terrestrial switch position Passive/Active Passive/Active Passive/Active Passive/Active Passive/Active
Tap loss (dB) 25±2 / 0±2 27±2 / 0±2 28±2 / 0±2 31±2 / 0±2 33±2 / 0±2
Attenuator (dB) - / 20 - / 20 - / 20 - / 20 - / 20
Maximal output level (60 dB IMA3)(1) (dBμV) - / 90 - / 88 - / 93 - / 90 - / 89
Trunk loss (dB) 3-5 3-5 3-5 4-6 4-6
Isolation SAT / TER (dB) >40 >40 >40 >40 >40
Isolation TER / SAT (dB) >40 >40 >40 >40 >40
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400 950-2400
Tap loss (dB) 0±2 0±2 0±2 0±2 0±2
Attenuator (dB) 6 6 6 6 6
Trunk loss (dB) 3-5 3-5 3-5 5-8 5-8
H/V isolation (dB) >25 >25 >25 >25 >25
SAT/SAT isolation (dB) >40 >40 >40 >40 >40
Maximal output level (35 dB IMA3)(2) (dBμV) 105 105 105 105 105
Maximum supply current 13 / 18 V (mA) 600 / 1.300 600 / 1.300 600 / 1.300 600 / 1.300 600 / 1.300
Power supply 94-265 / 47-63 Hz 94-265 / 47-63 Hz 94-265 / 47-63 Hz 94-265 / 47-63 Hz 94-265 / 47-63 Hz
Generator 22 KHz Yes Yes Yes Yes Yes
Dimensions (mm) 540x190x80 540x190x80 540x190x80 540x350x80 540x350x80
Weight (g) 3.230 3.270 3.310 3.590 3.670
17 IN cascadeable head multiswitchesDK series
Active SAT / TER*Indicator of selected inputInstallation wizard (patented)Terrestrial Push-Pull inputMade in Germany
DK SeriesCascade
DK 17x32 K
20
multiswitches
* Active / passive switch(1) DIN 45004 B(2) EN 50083-3
Active SAT / TER*Indicator of selected inputInstallation wizard (patented)Terrestrial Push-Pull inputMade in Germany
Reference DK 17x8 DK 17x12 DK 17x16 DK 17x24 DK 17x32
Code 01722.11 01723.11 01724.11 01730.11 01731.11
Inputs SAT / TER 16/1 16/1 16/1 16/1 16/1
Trunk outputs SAT / TER 16/1 16/1 16/1 16/1 16/1
Receiver outputs 8 12 16 24 32
Band frequecies (MHz) 5-862 5-862 5-862 5-862 5-862
Terrestrial switch position Passive Passive Passive Passive Passive
Loss (dB) 25±2 27±2 28±2 31±2 33±2
Band frequecies (MHz)*
5-65 / 80-862 5-65 / 80-862 5-65 / 80-862 5-65 / 80-862 5-65 / 80-862
Terrestrial switch position Active Active Active Active Active
Tap loss (dB) 25±2 / 0±2 27±2 / 0±2 28±2 / 0±2 31±2 / 0±2 33±2 / 0±2
Attenuator (dB) - / 20 - / 20 - / 20 - / 20 - / 20
Maximal output level (60 dB IMA3)(1)
(dBμV) - / 90 - / 88 - / 93 - / 90 - / 89
Trunk loss (dB) 2-4 2-4 2-4 4-7 4-7
Isolation SAT/TER (dB) >40 >40 >40 >40 >40
Isolation TER/SAT (dB) >40 >40 >40 >40 >40
Band frequecies (MHz) 950-2400 950-2400 950-2400 950-2400 950-2400
Tap loss (dB) 0±2 0±2 0±2 0±2 0±2
Trunk loss (dB) 2-4 2-4 2-4 4-7 4-7
H/V Isolation (dB) >25 >25 >25 >25 >25
SAT/SAT Isolation (dB) >40 >40 >40 >40 >40
Output level (35 dB IMA3)(2) (dBμV) 105 105 105 105 105
Current consumption receiver 13/18 V (mA) 100 100 100 100 100
Dimensions (mm) 380x110x80 380x190x80 380x190x80 380x350x80 380x350x80
Weight (g) 1.760 2.680 2.780 3.220 3.300
17 IN cascade multiswitchesDK series
DK SeriesCascade
DK 17x16DK 17x8
21
multiswitches
Amplifi erDK series
Reference DK 17 V
Code 01725.11
Inputs TER/SAT 1/16
Trunk outputs SAT / TER 1/16
Band frequencies (MHz) R.P. switchable 5-30 / 5-65
Gain (dB) 13±2
Passive mode loss (dB) 3±2
Regulation (dB) 20
Output level (60 dB IMA3)(1) (dBμV) 114
Band frequencies (MHz) 47-862 / 80-862
Active mode gain (dB)* 19-22
Passive mode loss (dB)* 3±2
Attenuator (dB) 20
Line equalizer (dB /MHz) 14 / 47-80
Trunk isolation TER/SAT (dB) >40
Trunk isolation SAT/TER (dB) >40
Output level (60 dB IMA3)(2) (dBμV) 114
Band frequencies (MHz) 950-2400
Gain (dB) 20±2
Attenuator (dB) 6
Line equalizer (dB) 10
Trunk isolation SAT/SAT (dB) >30
Output level (35 dB IMA3)(2) (dBμV) 112
Power supply 94-265 VAC /47-63 Hz
Dimensions (mm) 540x110x80
Weight (g) 1.560
DK SeriesAmplifi er
* Active / passive switch(1) DIN 45004 B(2) EN 50083-3
Return Path switchableAttenuatorLine equalizerTER amplifi er switchableMade in Germany
DK 17 V
22
multiswitches
Reference UCS 51820 UCS 52420
Code 51000.11 51002.11
Inputs SAT / TER 4 / 1 4 / 1
Trunk outputs SAT / TER 4 / 1 4 / 1
User outputs 1x8 2x4
Band frequencies (MHz) 5-862 5-862
Pass loss (dB) 2-5 2-5
Loss (dB) 6±2 6±2
Band frequencies (MHz) 950-2400 950-2400
Pass loss (dB) 3-5 3-5
Loss (dB) 6±2 6±2
Isolation (dB) >25 >25
Max. consumption (W) 18 18
Power supply 180-264 VAC/47-63 Hz 180-264 VAC/47-63 Hz
Power supply LNC 18 V max. / 500 mA 18 V max. / 500 mA
Dimensions (mm) 230x110x80 230x110x80
UCS SeriesUnicableTM multiswitches
5 IN Head UnicableTM multiswitchesUCS series
ANKARO UnicableTM multiswitches connect up to 8 receivers to one output. This technology uses Satellite Channel Routers (SCR) wich convert the LNB-signals selectively into 4 or 8 (depending on the model) new SAT-IF frequencies. These fre-quencies are combined in the multiswitch to a new SAT-IF band.
Each receiver must be linked to one SAT-IF band. To support the UnicableTM Technology these recei-vers must provide the extended DiSEqC standard. (EN 5094). Even old terrestrial systems or CATV systems can be changed to SAT reception, provi-ded that the cables are suitable.
UNICABLETM is a trademark of FTA Communication Technologies / Luxembourg
Return Path
Active SAT
Made in Germany
UCS 51820
23
multiswitches
UNICABLETM is a trademark of FTA Communication Technologies / Luxembourg
Reference UCS 51840 UCS 51440 UCS 52440
Code 51001.11 51004.11 51003.11
Inputs SAT / TER 4 / 1 4 / 1 4 / 1
Trunk outputs SAT / TER 4 / 1 4 / 1 4 / 1
User outputs 1x8 1x4 2x4
Band frequencies (MHz) 5-862 5-862 5-862
Pass loss (dB) 2-5 2-5 2-5
Loss (dB) 6±2 6±2 6±2
Band frequencies (MHz) 950-2400 950-2400 950-2400
Pass loss (dB) 3-5 3-5 3-5
Loss (dB) 6±2 6±2 6±2
Isolation (dB) >25 >25 >25
Dimensions (mm) 130x110x80 130x110x80 130x110x80
5 IN Cascade UnicableTM multiswitchesUCS series
UCS SeriesUnicableTM multiswitches
Return Path
Active SAT
Made in Germany
UCS 51840
24
multiswitches
UCS SeriesUnicableTM multiswitches
Reference UCS 91820 UCS 92420
Code 91000.11 91002.11
Inputs SAT / TER 8 / 1 8 / 1
Trunk outputs SAT / TER 8 / 1 8 / 1
User outputs 1x8 2x4
Band frequencies (MHz) 5-862 5-862
Pass loss (dB) 2-5 2-5
Loss (dB) 6±2 6±2
Band frequencies (MHz) 950-2400 950-2400
Pass loss (dB) 2-5 2-5
Loss (dB) 6±2 6±2
Isolation (dB) >25 >25
Power supply 180-265 VAC/50-60 Hz 180-265 VAC/50-60 Hz
Max. consumption (W) 26 26
Power supply LNC 18 V max. / 1200 mA 18 V max. / 1200 mA
Dimensions (mm) 400x110x80 400x110x80
9 IN Head UnicableTM multiswitchesUCS series
Return Path
Active SAT
Made in Germany
UNICABLETM is a trademark of FTA Communication Technologies / Luxembourg
UCS 91820
Ter8 x SAT-IF
8 x SAT-IF
UCS 91840
UCS 91820
AV 80/402
25
multiswitches
Reference UCS 91840 UCS 91440 UCS 92440
Code 91001.11 91004.11 91003.11
Inputs SAT / TER 8 / 1 8 / 1 8 / 1
Trunk outputs SAT / TER 8 / 1 8 / 1 8 / 1
User outputs 1x8 1x4 2x4
Band frequencies (MHz) 5-862 5-862 5-862
Pass loss (dB) 2-5 2-5 2-5
Loss (dB) 6±2 6±2 6±2
Band frequencies (MHz) 950-2400 950-2400 950-2400
Pass loss (dB) 2-5 2-5 2-5
Loss (dB) 6±2 6±2 6±2
Isolation (dB) >25 >25 >25
Dimensions (mm) 240x110x80 240x110x80 240x110x80
9 IN Cascade UnicableTM multiswitchesUCS series
UCS SeriesUnicableTM multiswitches
Reference 51820 51840 51440 52420 52440
Reference 91820 91840 91440 92420 92440
Receiver 1 (MHz) 1400 1400 1400 1400 1400
Receiver 2 (MHz) 1632 1632 1632 1632 1632
Receiver 3 (MHz) 1284 1284 1284 1284 1284
Receiver 4 (MHz) 1516 1516 1516 1516 1516
Receiver 5 (MHz) 1864 1864 - - -
Receiver 6 (MHz) 2096 2096 - - -
Receiver 7 (MHz) 1748 1748 - - -
Receiver 8 (MHz) 1980 1980 - - -
Frequencies assigned to receiver*
*Other frequencies available if ordered
Return Path
Active SAT
Made in Germany
UNICABLETM is a trademark of FTA Communication Technologies / Luxembourg
UCS 91840
26
multiswitches
ASV SeriesMultisplitters
Reference ASV 502 ASV 902 ASV 503 ASV 903
Code 01181.11 01199.11 01179.11 01180.11
Inputs / outputs 5 / 2x5 9 / 2x9 5 / 3x5 9 / 3x9
Band frequencies (MHz) 5-862 5-862 5-862 5-862
Attenuation (dB) 4 4 17±2 17±2
Trunk loss (dB) - - 1-2 1-2
Band frequencies (MHz) 950-2400 950-2400 950-2400 950-2400
Amplification (dB) 7-12 7-12 5-10 5-10
Noise figure (dB) 4 4 1-2 1-2
Output level (35 dB IMA3) (dBμV) 102 102 105 105
Isolation SAT / SAT >40 >40 >40 >40
Isolation TER / SAT >40 >40 >40 >40
Power consumption remote power (mA) 4x60 8x60 4x60 8x60
Dimensions (mm) 130x110x70 280x110x70 180x110x70 280x110x70
Weight (g) 500 770 520 820
5/9 inputs active multisplittersASV series
Active SAT
Made in Germany
ASV 502 ASV 903
ASV 902
8 x 75 Ohm 8 x 75 Ohm 8 x 75 Ohm
8 x 75 Ohm
8 x 75 Ohm
8
8 8 8
88
KAD 9x16 KAD 9x16 KAD 9x16
KAD 9x16
KAD 9x16
KAD 9x32 K KAD 9x32 K KAD 9x32 K
ASV 903
8
27
multiswitches
KA
D 9
x16
KA
D 2
2 V
16
16
KA
D 9
x32
K
KA
D 9
x16
KA
D 2
2 V
16
16
KA
D 9
x32
K
Multitaps with 4 or 8 SAT-IF tap-offs and 1 terrestrialtap-off.All types are available with 12, 18 or 24 dB tap-loss and a DC- connection from trunk-input to trunk output.Multitaps are used in big trunk lines in order to simplify connection of single multiswitches or cascaded clusters on several fl oors or buildings.
Reference MT 0512 MT 0518 MT 0524
Code 01182.11 01183.11 01184.11
Inputs / taps 5 / 2x5 5 / 2x5 5 / 2x5
Trunk loss (dB) 1 1 1
Tap loss (dB) 12 18 24
Dimensions (mm) 130x110x60 130x110x60 130x110x60
Weight (g) 540 540 540
Reference MT 0912 MT 0918 MT 0924
Code 01185.11 01186.11 01187.11
Inputs / taps 9 / 2x9 9 / 2x9 9 / 2x9
Trunk loss (dB) 1 1 1
Tap loss (dB) 12 18 24
Dimensions (mm) 280x110x60 280x110x60 280x110x60
Weight (g) 770 770 770
5 IN Multitaps SAT + TerrestrialMT series
9 IN Multitaps SAT + TerrestrialMT series
MT SeriesMultitaps
Made in Germany
MT 0518
MT 0924
KAD 22 V
MT 0918
MT 0912
28
multiswitches
Reference ACS 7000
Code 01182.11
Connections COM-port (D-SUB 9 Pin)
ANCASY data port (RJ 11)
GSM antenna port (MMCX)
Earth connection
Slot for SIM card
Power supply 180-265 VAC / 47-63 Hz
Control module
Ancasy allows
switch on/off the satellite signal of eachsubscriber individuallyswitch on/off the satellite signal completelyor selectivelycontrol the distribution locally or remote vía GPRSsupply the terrestrial path continuously
Ancasy supports...
the ANKARO patented installation wizardthe switch position indicatorthe switching of the terrestrial input from active to passiveDiSEqC 2.0
Ancasy distribution components
ACS 7000 N Control moduleACS 17x16 K (7001) Head multiswitchACS 17x32 K (7003) Head multiswitchACS 17x16 (7002) Cascade multiswitchACS 17x32 (7004) Cascade multiswitch
ANKARO Conditional Access System ANCASY assigns specific IF-bands individually to each subscriber.Each subscriber is charged according to his individual SAT-IF demand by the provider. ANCASY IF-distribution systems open new business fields and market concepts.
ANCASY IF-distribution systems are to be planned and installed as common systems with multiswitches.However, the multiswitches have to be interconnected additionally with a twisted-pair data-cable with RJ45connectors to transfer the subscriber data (e.g. switch on/off SAT-IF bands) to the multiswitches.
The system provider can easily control and collect all system data by GSM short message service (SMS)from for distance.
One SMS transfers the data of one multiswitch with max.16 SAT-IF inputs and max. 32 subscriber outputs.One control-module can manage maximum16 multiswitches with 512 subscriber outputs.
ACS 7000
ACS 17x16 K
ACS 17x16
ACS 7000
GSM Antenna
29
multiswitches
ACS 17x16 K
Reference ACS 17x16 K ACS 17x32 K
Code 07001.11 07003.11
Inputs SAT / TER 16 / 1 16 / 1
Trunk outputs SAT / TER 16 / 1 16 / 1
User outputs 16 32
Band frequencies (MHz) passive mode* 5-862 5-862
Loss (dB) 28±2 33±2
Band frequencies (MHz) active mode* 5-65 / 80-862Passive / Active
5-65 / 80-862Passive / Active
Loss (dB) 28±2 / ±2 33±2 / 0±2
Output level (60 dB IMA3)(1) (dBμV) - / 82 - / 79
Trunk loss 3-5 4-6
Isolation trunk Ter-Sat >40 >40
Isolation trunk Sat-Ter >40 >40
Band frequencies (MHz) 950-2400 950-2400
Gain (dB) 0-5 0-5
Regulation (dB) -6 -6
Trunk loss (dB) 3-5 5-8
H/V isolation (dB) >25 >25
Isolation trunk Sat-Sat >40 >40
Output level (35 dB IMA3)(2) (dBμV) 100 100
Current consumption receiver 13/18V 100 100
Power supply 94-265 VAC / 50-60 Hz 94-265 VAC / 50-60 Hz
Max. consumption (W) 42 42
Power supply LNC 12V/18V 600 / 1300 600 / 1300
22 KHz generator Yes Yes
Dimensions (mm) 540x190x80 540x350x80
Weight (g) 3.310 3.590
17 IN conditional access head multiswitchesACS series
SeriesConditionalAccess multiswitches
* Active/passive switchable(1) DIN 45004 B(2) EN 50083-3
Active SAT / TERIndicator of selected inputInstallation wizard (patented)Terrestrial Push-Pull inputMade in Germany
30
multiswitches
Reference ACS 17x16 ACS 17x32
Code 07002.11 07004.11
Inputs SAT / TER 16 / 1 16 / 1
Trunk outputs SAT / TER 16 / 1 16 / 1
User outputs 16 32
Band frequencies (MHz) passive mode* 5-862 5-862
Loss (dB) 28±2 33±2
Band frequencies (MHz) active mode* 5-65 / 80-862Passive / Active
5-65 / 80-862Passive / Active
Loss (dB) 28±2 / 0±2 33±2 / ±2
Output level (60 dB IMA3)(1) (dBμV) - / 82 - / 79
Trunk loss 2-4 4-6
Isolation trunk Ter-Sat >40 >40
Isolation trunk Sat-Ter >40 >40
Band frequencies (MHz) 950-2400 950-2400
Gain (dB) 0-5 0-5
Trunk loss (dB) 3-5 5-8
H/V isolation (dB) >25 >25
Isolation trunk Sat-Sat >40 >40
Output level (35 dB IMA3)(2) (dBμV) 100 100
Current consumption receiver 13/18V (mA) 100 100
Dimensions (mm) 380x190x80 380x350x80
Weight (g) 2.780 3.300
17 IN conditional access cascade multiswitchesACS series
SeriesConditionalAccess multiswitches
* Active/passive switchable(1) DIN 45004 B(2) EN 50083-3
Active SAT / TER*Indicator of selected inputInstallation wizard (patented)Terrestrial Push-Pull inputMade in Germany
ACS 17x16
31
MATV amplifiers (AV series) ........... 32CATV amplifiers (BKV series) ......... 34SMATV amplifiers ........................... 36
amplifi ers
32
amplifi ers
MATV amplifi ers
Reference AV 60/131 AV 60/200 AV 60/132
Code 06011.11 06013.11 06012.11
Inputs 3 (FM / BIII / UHF) 2 (FM / BIII + UHF) 3 (BI / BIII / UHF)
Gain (dB) FM: 22 / BIII: 22 / UHF: 22 FM: 20 / BIII: 20 / UHF: 22 BI: 22 / BIII: 22 / UHF: 22
Max. output level (60 dB IMA3)(1) (dBμV) 110 110 110
Noise fi gure (dB) 5-7 5-7 5-7
Power supply 230 VAC / 50 Hz 230 VAC / 50 Hz 230 VAC / 50 Hz
Reference AV 60/331 AV 60/300 AV 60/342
Code 06060.11 06061.11 06071.11
Inputs 3 (AM+FM / BIII / UHF) 2 (FM / BIII + UHF) 3 (BI / BIII / UHF)
Gain (dB) AM+FM: 30 / BIII: 30 / UHF: 32 FM: 30 / BIII: 30 / UHF: 32 BI: 30 / BIII: 30 / UHF: 32
Attenuator (dB) 20 20 20
Max. output level (60 dB IMA3)(1) (dBμV) 114 114 114
Noise fi gure (dB) 5-7 5-7 5-7
Power supply 230 VAC / 50 Hz 230 VAC / 50 Hz 230 VAC / 50 Hz
Supply terminal for pre-amplifi er +12V = +12V = +12V =
MATV amplifi ersAV series
MATV amplifi ersAV series
(1) DIN 45004 B
(1) DIN 45004 B
AV 60/331
AV 60/131
33
amplifi ers
MATV amplifi ers
Reference B1F FMF B3F DAB F B4F B5F
Code 08300 BI 08300 FM 08300 B3 08300 DAB 08300 B4 08300 B5
Description Insertable filterBI
Insertable filterFM
Insertable filterBIII
Insertable filterBand DAB
Insertable filterBand IV
Insertable filterBand V
Frequency pass (MHz) 47-68 87-108 175-230 190-224 470-606 606-862
Packaging 1 1 1 1 1 1
Reference AV 80/401 AV 80/402 AV 90/501 AV 90/502
Code 08380.11 08381.11 08390.11 08391.11
Inputs and band 2: VHF / 1: UHF 2: VHF / 2: UHF 2: VHF / 1: UHF 2: VHF / 2: UHF
Gain (dB) VHF1: 30 / VHF2:18 / UHF: 41
VHF1: 30 / VHF2: 18 / UHF: 37
VHF: 44 / UHF: 56 VHF: 44 / UHF: 54
Attenuator (dB) VHF: 18 / UHF: 15 VHF: 18 / UHF: 15 VHF: 20 / UHF: 20 VHF: 20 / UHF: 20
Output level (60 dB IMA3) (dBμV)DIN 45004 B
114 114 125 125
Test output (dB) - - -30 -30
Vdc Pass (12 Vcc) Yes / 1UHF Yes / 2 UHF Yes / 1UHF Yes / 2 UHF
Power supply (VAC) 198-253 / 47-63 Hz 198-253 / 47-63 Hz 198-253 / 47-63 Hz 198-253 / 47-63 Hz
Housing Aluminium / IP40 Aluminium / IP40 Aluminium / IP40 Aluminium / IP40
Insertable Filtersfor configurable amplifiers AV 60 / 80 series
MATV amplifi ers (aluminium housing)AV series
AV 80/402
FMF B3F
34
amplifi ers
CATV amplifi ers
Reference BKV 30/200 F BKV 30/300 F
Code 08409.11 08430.12
Inputs / Outputs 1 / 1 1 / 1
Frequency range (MHz) 47-862 47-862
Gain (dB) 20 30
Attenuator (dB) 20 20
Noise fi gure (dB) 6 7
Max. output level (60 dB IMA3)(1) (dBμV) 110 114
Power supply 230 VAC / 50 Hz 230 VAC / 50 Hz
Dimensions (mm) 112x73x43 112x73x43
Weight (g) 330 330
CATV amplifi ersBKV series
Reference BKV 22/30 BKV 22/65
Code 08422.11 08423.11
Inputs / outputs 1 / 1 1 / 1
Frequencies (MHz) 47-862 85-862
Gain (dB) 22±1,5 22±1,5
Attenuator (dB) 0-20 0-20
Line equalizer (dB) 0-10 0-10
Output level (dBμV) DIN 45004BEN 50083-3 > 60 dB 42 CH
115100
115100
Band frequency R.P. (MHz) 5-30 5-65
Gain R.P. (dB) Active: 20 / Passive: >-2,5 Active: 20 / Passive: >-2,5
Regulation return path (dB) Active: 0-20 Active: 0-20
Output level R.P. (60 dB IMA3)(1) (dBμV) Active: 115 Active: 115
Power supply (VAC) 198-253 / 47-63 Hz 198-253 / 47-63 Hz
Housing Aluminium / IP 40 Aluminium / IP 40
CATV amplifi ers (aluminium housing)BKV series
(1) DIN 45004 B
(1) DIN 45004 B
BKV 22/30
BKV 30/200 F
35
amplifi ers
CATV amplifi ers
Reference BKV 32/30 BKV 32/65
Code 08432.11 08433.11
Inputs / outputs 1 / 1 1 / 1
Frequencies (MHz) 47-862 85-862
Gain (dB) 32±1,5 32±1,5
Attenuator (dB) 0-20 0-20
Line equalizer (dB) 0-10 0-10
Output level (dBμV) DIN 45004BEN 50083-3 > 60 dB 42 CH
115100
115100
Band frequency R.P. (MHz) 5-30 5-65
Gain R.P. (dB) Active: 28 Active: 28
Attenuator R.P. (dB) Active: 0-20 Active: 0-20
Output level R.P. (60 dB IMA3)(1) (dBμV) Active: 115 Active: 115
Power supply (VAC) 198-253 / 47-63 Hz 198-253 / 47-63 Hz
Housing Aluminium / IP 40 Aluminium / IP 40
CATV amplifi ers (aluminium housing)BKV series
(1) DIN 45004 B
Reference BKV 42/30 BKV 42/65
Code 08437.11 08438.11
Inputs / outputs 1 / 1 1 / 1
Frequencies (MHz) 47-862 85-862
Gain (dB) 42 ±1,5 42 ±1,5
Attenuator (dB) 0-20 0-20
Attenuation between band (dB) 6 6
Line equalizer (dB) 0-10 0-10
Equalization between stages (dB) 6 6
Output level (dBμV) DIN 45004BEN 50083-3 > 60 dB 42 CH
124111
124111
Band frequency R.P. 5-30 5-65
Gain R.P. (dB) Active: 30 / Passive: >-2,5 Active: 30 / Passive: >-2,5
Attenuator R.P. (dB) Active: 0-20 Active: 0-20
Line equalizer R.P. (dB) (dBμV) 0-10 0-10
Output level R.P. (dBμV) DIN 45004 B Active: 120 Active: 120
Test output -30 -30
Power supply (VAC) 198-253 / 47-63 Hz 198-253 / 47-63 Hz
Housing Aluminium / IP 65 Aluminium / IP 65
CATV amplifi ers (aluminium housing)BKV series
BKV 42/30
36
amplifi ers®
SMATV amplifi ers
Reference SEV 1213 SLV 40 VV STV 1228 VV
Code 01213.11 01240.11 01228.11
Inputs 1:TER (47-862MHz) 1:SAT (950-2200MHz)
1:TER (47-862MHz) 1:SAT (950-2200MHz)
1:TER (47-862MHz) 1:SAT (950-2200MHz)
Outputs 1 1 1
Gain (dB) TER: 1SAT: 25-30
TER: 1SAT: 36-40
TER: 5SAT: 39-42
Attenuator (dB) TER: -SAT: 10
TER: -SAT: 12
TER: -SAT: 12
Line equalizer (dB) TER: -SAT: 10
TER: -SAT: 10
TER: -SAT: 10
Output level (dBμV) DIN 45004B IMD3 -35 dB
TER: -SAT: 114
TER: -SAT: 120
TER: -SAT: 124
LNC supply (mA) 250 350 350
Power supply 230 VAC / 50-60 Hz 198-253 VAC / 47-63 Hz 198-253 VAC / 47-63 Hz
Reference SLV 40 AN STV 1227 NV
Code 01207.11 01227.11
Inputs 1:SAT (950-2200 MHz) /1:SAT+TER (47-2200MHz)
1:SAT (950-2200 MHz) /1:SAT+TER (5-2200MHz)
Outputs 1 2
Gain (dB)TER/SAT
TER: 36-40SAT: 36-40
R. P: - 2TER: 37SAT: 39-42
Attenuator (dB)TER/SAT
TER: 20SAT: 12
TER: 20SAT: 12
Line equalizer (dB)TER/SAT
TER: 14SAT: 10
TER: 12SAT: 10
Output level (dBμV)TER/SAT DIN 45004B
TER: 115SAT:120
TER: 116SAT:124
Power supply 198-253 VAC/ 47-63 Hz 198-253 VAC/ 47-63 Hz
Headend amplifi ers
Line amplifi ers
SEV 1213
SLV 40 AN
37
fi eld meters
MDL series .......................... 38MDX series .......................... 41
38
fi eld meters
Technical Features MDL Compact and light, with dimensions 270 x 170 x 70 mm and weight 1,8 Kg HPR Function (ANKARO Headends Programmer) Extremely intuitive. Very easy to use High Resolution Spectrum with horizontal sweep and logarithmic amplitude Battery Duration: 2,5 hours TFT 5" HQ Provides all the measurements in a unique window Super advanced Data-logger Auto Reference Level in spectrum Digital Picture in MPEG-2 Noise figure function Satellite Identifier DiSEqC motors control Auto identifier of the Digital carriers Real measurements of BER Simple and fast upgrading through USB 2.0 Data transfer to the PC through USB 2.0 stick SatCR compatible Wide connectivity: USB 2.0, RS-232, A/V IN, A/V OUT Same user interface than the MDX series HDTV measures Constellation diagram in DVB-S/S2
39
fi eld meters
MDL 100
MDL 200
MDL 300
MDL 400
Picture
Satellite-AnalogueSpectrum
Meas Band
Channel
Band /Channel
Auto-Scan
DataloggerFull
BasicPicture
Spectrum
Meas
-SNoise Margin
QEF
dB
YES
YES
Picture
Spectrum
Meas
-S2
Picture
Spectrum
Meas
-T
ConstellationQPSK
8PSK
Picture
Terrestrial-AnalogueSpectrum
Meas
Picture
Satellite-AnalogueSpectrum
Meas
DataloggerFull
Basic
Band /ChannelBand
Channel
Auto-Scan
SynchronismYES
HDTVNoise Margin
QEF
dB
YES
Picture
Spectrum
Meas
-S
YES
Picture
Spectrum
Meas
-S
Picture
Terrestrial-AnalogueSpectrum
Meas
Picture
Spectrum
Meas
-T
DataloggerFull
Basic
YES
Picture
Satellite-AnalogueSpectrum
Meas
Band /ChannelBand
Channel
Auto-Scan
SynchronismYES
Noise MarginQEF
dB
YES
Picture
Satellite-AnalogueSpectrum
Meas
ConstellationQPSK
8PSK
YES
Picture
Spectrum
Meas
-S2HDTV
Band /ChannelBand
Channel
Auto-ScanPicture
Spectrum
Meas
-S
DataloggerFull
Basic
Noise MarginQEF
dB
YES
HPR100
Headends AnkaroProgrammer
HPR100
Headends AnkaroProgrammer
HPR100
Headends AnkaroProgrammer
HPR100
Headends AnkaroProgrammer
40
fi eld meters
Signal metersMDL series
MDL 300DVB-S + DVB-TSignal meter
MDL 400DVB-S2 + DVB-T (HDTV)Signal meter
Reference MDL 100 MDL 200 MDL 300 MDL 400
Code 0001000 0001001 0001002 0001003
Frequency 950 - 2150 (MHz) 950 - 2150 (MHz) 47-862 and 950-2150 (MHz) 47-862 and 950-2150 (MHz)
Input Impedance 75 Ohms 75 Ohms 75 Ohms 75 Ohms
Measurement Range 20 dBμV to 130 dBμV 20 dBμV to 130 dBμV 20 dBμV to 130 dBμV 20 dBμV to 130 dBμV
Digital StandardsQPSK 8 PSK / QPSK QPSK / COFDM /
QAM emulated8 PSK / QPSK / COFDM /QAM emulated
AnalogueMeasurements
Level, Video/Audio,C/N
Level, Video/Audio,C/N
Level, Video/Audio, C/N,video line
Level, Video/Audio, C/N,video line
DigitalMeasurements
Channel Power, BER, MER, Total Errors, C/N, Quality, Noise Margin
Channel Power, BER, MER, Total Errors, C/N, Quality, measurament channels DVB-S2,Noise Margin
Channel Power, BER, MER, Total Errors, C/N, Quality,Noise Margin
Channel Power, BER, MER, Total Errors, C/N, Quality, measurament channelsDVB-S2, Noise Margin
Spectrum Logarithmic Logarithmic Logarithmic Logarithmic
Analogue Picture No No Yes (terrestrial) Yes (terrestrial)
Digital Picture Yes (QPSK) Yes (QPSK) Yes (QPSK / COFDM ) Yes (QPSK / COFDM )
Constellation diagram No Yes (QPSK / 8PSK) No Yes (QPSK / 8PSK)
Spectrum position Horizontal Horizontal Horizontal Horizontal
Dynamic range 50 dB 50 dB 50 dB 50 dB
Resolution Filters 1 MHz 1 MHz 1 MHz 1 MHz
Monitor TFT 5" colour TFT 5" colour TFT 5" colour TFT 5" colour
Interfaces USB 2.0 / IN A-V /OUT A-V / RS-232
USB 2.0 / IN A-V /OUT A-V / RS-232
USB 2.0 / IN A-V /OUT A-V / RS-232
USB 2.0 / IN A-V /OUT A-V / RS-232
Data-logger Yes Yes Yes Yes
Battery Duration 2,5 hours 2,5 hours 2,5 hours 2,5 hours
Dimensions (mm) 270 x 170 x 70+ transport bag
270 x 170 x 70+ transport bag
270 x 170 x 70+ transport bag
270 x 170 x 70+ transport bag
Weight (g) 1,8 + transport bag 1,8 + transport bag 1,8 + transport bag 1,8 + transport bag
Battery Lithium - Ion Lithium - Ion Lithium - Ion Lithium - Ion
Decoder MPEG-2 Included Included Included Included
Power supply LNB 13V, 18 V, 13 V+22 KHz,18 V+22 KHz
13V, 18 V,13 V+22 KHz,18 V+22 KHz
5V, 13 V, 18 V,13 V+22 KHz,18 V+22 KHz
5V, 13 V, 18 V,13 V+22 KHz,18 V+22 KHz
DiSEqC System 1.2 System 1.2 System 1.2 System 1.2
Battery Charger 20 V / 2,5 A 20 V / 2,5 A 20 V / 2,5 A 20 V / 2,5 A
MDL 100DVB-SSignal meter
MDL 200DVB-S2 (HDTV)Signal meter
41
fi eld meters
MDX Series
Additional Technical FeaturesMDX 600 Picture
Spectrum
Meas
-T Picture
Spectrum
MeasS2
-HDetector
ConstellationQPSK
8 PSK
QAM
RadioYESYES
RECSTREAM
Measurements in DVB-S2 Displaying of the constellation diagram in DVB-S, DVB-S2 and QAM Full Band RF: 5-862 MHz and 863-2150 MHz Maximum detection mode to view interferences or GSM signals. Peak Hold Recording of the complete Transport Streams in USB 2.0 external Hard Disks Double marker in spectrum mode
Common Technical FeaturesMDX 500 and MDX 600Easy and amazing interface and useCustomizable by the userHigh Resolution SpectrumHigh Battery duration, 4h30 guaranteedSimultaneous viewing of measures+spectrum+picture in DVBTFT 5” HQProvides all the measurements in a unique screenSuper advanced Data-loggerAuto Reference Level in spectrumNoise figure functionSynchronism Pulse viewingAnalogue Picture in Satellite and TerrestrialDigital Picture in MPEG-2Satellite IdentifierECHOS function (impulse and frequency response)DiSEqC motors controlAuto identifier of the digital carriersConstellation Diagram in DVB-CReal measurements of BER in DVB-T, DVB-S and DVB-CSimple and fast upgrading through USB 2.0Data transfer to the PC through USB 2.0 stickSatCR compatible
Picture
Spectrum
Meas
-S
Picture
Analogue-TerrestrialSpectrum
Meas
Constellation QAM
Datalogger YES
Picture
Spectrum
Meas
-T
Picture
Spectrum
Meas
-C
Picture
Satellite-Analogue
Spectrum
Meas
YES
Auto-Scan
ECHOS function YES
Radio YES
SISynchronism
Noise MarginQEF
dB
YES
42
fi eld meters
Reference MDX 500 MDX 600
Code 0001004 0001006
Frequency 5-862 and 900-2150 MHz 5-862 and 863-2150 MHz
Input impedance 75 Ohms 75 Ohms
Measurement range 20 dBμV to 130 dBμV 20 dBμV to 130 dBμV
Digital standards QPSK / COFDM / QAM 8PSK / QPSK / COFDM / QAM
Analogue measurements Level, Video/Audio, C/N, synchronism impulse Level, Video/Audio, C/N, synchronism impulse, video line
Digital measurementsChannel Power, BER, MER, Total errors,C/N, Quality, Noise margin
Channel Power, BER, MER, Total errors, C/N,Measurement Channels DVB-S2 Quality, Noise margin
Spectrum Logarithmic Logarithmic
Analogue picture Yes (Terrestrial / Satellite) Yes (Terrestrial / Satellite)
Digital picture Yes (COFDM / QAM / QPSK) Yes (COFDM / QAM / QPSK)
Constellation diagram Yes (QAM) Yes (QAM / QPSK / 8PSK)
Spectrum position Horizontal Horizontal
Dynamic margin 50 dB 50 dB
Resolution fi lters 2,5 MHz, 1 MHz, 250 KHz 2,5 MHz, 1 MHz, 250 KHz
Monitor TFT 5" colour TFT 5" colour
Interfaces USB 2.0 / (IN-OUT A-V) / RS-232 USB 2.0 / (IN-OUT A-V) / RS-232
Data-logger Yes Yes
Battery duration 4,5 hours without LNB 4,5 hours without LNB
Dimensions (mm) 280x130x220 + transport bag 280x130x220 + transport bag
Weight (g) with bag 5,0 with bag 5,0
Battery type Lithium - Ion Lithium - Ion
Decoder MPEG-2 Included Included
Power supply LNB 5V, 13V, 18V, 13V+22 KHz, 18V+22 KHz 5V, 13V, 18V, 13V+22 KHz, 18V+22 KHz
DiSeqC System 1.2 System 1.2
Battery charger 20 V / 2,5 A 20 V / 2,5 A
Signal metersMDX series
MDX 500DVB-S + DVB-T + DVB-CSignal meter
MDX 600DVB-S2 + DVB-T + DVB-C(HDTV) Signal meter
MDX 500
headends
43
MDL series Pag. 38MDX series Pag. 41
IP Digital Headend receivers ...........44VSB Transmodulators .....................47Transmodulators .............................49Headend Modulator ........................51Processors and regenerators ..........52Amplifiers and Power supplies ........59Accessories ....................................55
44
headends
Reference HSIP 100 HSIP 100 CI
Code 20032.11 20036.11
Description DVB-S / DVB-S2 --> IPTV DVB-S / DVB-S2 (CI) --> IPTV
Input RF connector Female F connector Female F connector
Input frequency range (MHz) 950-2150 950-2150
Input Level (dBm) -25 to -65 -25 to -65
Input impedance () 75 75
Symbol speed (MS/s) DVB-S:1-45DVB-S2:1-36(QPSK)/1-30(8PSK)
DVB-S:1-45DVB-S2:1-36(QPSK)/1-30(8PSK)
Modulation QPSK / 8PSK QPSK / 8PSK
FEC DVB-S: 1/2,2/3,3/4,5/6,6/7,7/8DVB-S2: 1/2,3/5,2/3,3/4,4/5,5/6,8/9,9/10
DVB-S: 1/2,2/3,3/4,5/6,6/7,7/8DVB-S2: 1/2,3/5,2/3,3/4,4/5,5/6,8/9,9/10
Loss in LOOP (dB) <1 <1
Services/programs fi ltering Up to 8 Up to 8
LNC Power supply 13/18V, 0/22 KHz 13/18V, 0/22 KHz
LAN interface connector RJ-45 RJ-45
LAN interface protocol Ethernet 802,3 Ethernet 802,3
Output speed (Mbps) 10/100 10/100
Network protocol SAP / SDP SAP / SDP
IGMP protocol v1, v2 v1, v2
IP encapsulation and extraction MPEG 2 / MPEG 4 over IP (ETSI EN 301 192) MPEG 2 / MPEG 4 over IP (ETSI EN 301 192)
Table pass or extraction NIT, SDT, EIT & TDT NIT, SDT, EIT & TDT
Tables regeneration PAT, PMT & CAT PAT, PMT & CAT
Conditional access No Yes, 2 slots
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Weight (g) 1.200 1.300
Consumption 5V (mA) DVB-S: <800DVB-S2: <1500
DVB-S: <1050 + PCMCIA'sDVB-S2: <1750 + PCMCIA’s
Consumption 24V (mA) <250 <250
Packaging 1 1
IP Digital Headend receiversIP 100 series
QPSK input Wall mount/rack compatibleMade in Europe
HSIP 100 HSIP 100 CI
45
headends
Reference HTIP 100 HTIP 100 CI
Code 20030.11 20034.11
Description DVB-T --> IPTV DVB-T (CI) --> IPTV
Input RF connector Female F connector Female F connector
Input frequency range (MHz) VHF: 174 - 230UHF: 470 - 862
VHF: 174 - 230UHF: 470 - 862
Input Level (dBm) 43-88 43-88
Bandwidth (MHz) DVB-T (7-8) DVB-T (7-8)
Input impedance () 75 75
FEC 1/2, 2/3,3/4,5/6,7/8 1/2, 2/3,3/4,5/6,7/8
Loss in LOOP (dB) <1 <1
Modulation COFDM COFDM
Services/programs fi ltering Up to 8 Up to 8
Reception mode DVB-T (2K,8K) DVB-T (2K,8K)
LAN interface connector RJ-45 RJ-45
LAN interface protocol Ethernet 802,3 Ethernet 802,3
Output speed (Mbps) 10/100 10/100
Network protocol SAP / SDP SAP / SDP
IGMP protocol v1, v2 v1, v2
IP encapsulation and extraction MPEG 2 / MPEG 4 over IP (ETSI EN 301 192) MPEG 2 / MPEG 4 over IP (ETSI EN 301 192)
Table pass or extraction NIT, SDT, EIT & TDT NIT, SDT, EIT & TDT
Tables regeneration PAT, PMT & CAT PAT, PMT & CAT
Conditional access No Yes, 2 slots
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Weight (g) 1.200 1.300
Consumption 5V (mA) <1000 <1250 + PCMCIA's
Packaging 1 1
IP Digital Headend receiversIP 100 series
COFDM input Wall mount/rack compatibleMade in Europe
HTIP 100 HTIP 100 CI
46
headends
Reference HCIP 100 HCIP 100 CI
Code 20038.11 20040.11
Description DVB-C --> IPTV DVB-C (CI) --> IPTV
Input RF connector Female F connector Female F connector
Input frequency range (MHz) 50-858 50-858
Input Level (dBm) 42-82 42-82
Bandwidth (MHz) 8 8
Symbol speed (MS/s) 1,9 - 6,9 1,9 - 6,9
Services/programs fi ltering Up to 8 Up to 8
Loss in LOOP (dB) <1 <1
Input impedance () 75 75
Modulation QAM QAM
LAN interface connector RJ-45 RJ-45
LAN interface protocol Ethernet 802,3 Ethernet 802,3
Output speed (Mbps) 10/100 10/100
Network protocol SAP / SDP SAP / SDP
IGMP protocol v1,v2 v1,v2
IP encapsulation and extraction MPEG 2 / MPEG 4 overIP (ETSI EN 301 192)
MPEG 2 / MPEG 4over IP (ETSI EN 301 192)
Table pass or extraction NIT, SDT, EIT & TDT NIT, SDT, EIT & TDT
Tables regeneration PAT, PMT & CAT PAT, PMT & CAT
Conditional access No Yes, 2 slots
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Weight (g) 1.200 1.300
Consumption 5V (mA) <1000 <1250 + PCMCIA's
Packaging 1 1
IP Digital Headend receiversIP 100 series
QAM inputWall mount/rack compatibleMade in Europe
HCIP 100 HCIP 100 CI
47
headends
Reference HSAR 100 HSAR 100 CI
Code 20000.11 20002.11
Description DVB-S --> PAL/SECAM (multistandard) DVB-S (CI) --> PAL/SECAM (multistandard)
Input RF connector Female F connector Female F connector
Input frequency range (MHz) 950-2150 950-2150
Input level (dBm) -25 to -65 -25 to -65
Input bandwidth (MHz) 36 36
Input impedance () 75 75
Loss in LOOP (dB) <1 <1
FEC 1/2, 2/3,3/4,5/6,7/8 1/2, 2/3,3/4,5/6,7/8
LNC Power supply 13/18V, 0/22 KHz 13/18V, 0/22 KHz
Modulation QPSK QPSK
Symbol speed (MS/s) QPSK: 2-45 QPSK: 2-45
Profi le level MPEG-2 MP@ML MPEG-2 MP@ML
Transport stream MPEG-2 ISO/ IEC 13818 MPEG-2 ISO/ IEC 13818
Video resolution PAL:720X576 NTSC:720X480 PAL:720X576 NTSC:720X480
Audio response 20 Hz -20 kHz <+/-2dB - 60Hz -18kHz <+/-0,5dB 20 Hz -20 kHz <+/-2dB - 60Hz -18kHz <+/-0,5dB
Programming connector RJ-45 RJ-45
Programmer HPR 100 HPR 100
Programming Display / OSD Display / OSD
Output RF connectors Female F connector Female F connector
Output level (dBμV) 82 + 1 / - 3 82 + 1 / - 3
Regulation margin (dB) 15 15
Output channels C2-C69 C2-C69
Type of modulator VSB / STEREO VSB / STEREO
Video S/N relation (dB) >54 >54
MIX loss (dB) <1 <1
Modulation standard B-G, D-K,L, I B-G, D-K,L, I
Spurious level (dBc) -60 -60
Conditional access No Yes, 1 slot
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Weight (g) 1.400 1.400
Consumption 5V (mA) <800 <800 + PCMCIA
Consumption 12V (mA) <400 <400
Consumption 30V (mA) <3 <3
Packaging 1 1
VSB TransmodulatorsHSAR series
QPSK input Wall mount/rack compatibleMade in Europe
HSAR 100 HSAR 100 CI
48
headends
Reference HTAR 100 HTAR 100 CI
Code 20004.11 20006.11
Description DVB-T --> PAL/SECAM (multistandard) DVB-T (CI) --> PAL/SECAM (multistandard)
Input RF connector Female F connector Female F connector
Input frequency range (MHz) 170 - 230 / 470 - 862 170 - 230 / 470 - 862
Input level (dBμV) 43-88 43-88
Input bandwidth (MHz) DVB-T (7-8) DVB-T (7-8)
Input impedance () 75 75
Loss in LOOP (dB) <1 <1
Modulation COFDM COFDM
Services/programs fi ltering 1 1
Reception mode DVB-T (2K, 8K) DVB-T (2K, 8K)
Profi le level MPEG-2 MP@ML MPEG-2 MP@ML
Transport stream MPEG-2 ISO/ IEC 13818 MPEG-2 ISO/ IEC 13818
Video resolution PAL:720X576 NTSC:720X480 PAL:720X576 NTSC:720X480
Audio response 20Hz -20 kHz <+/-2dB 60Hz -18kHz <+/-0,5dB
20Hz -20 kHz <+/-2dB 60Hz -18kHz <+/-0,5dB
Programming connector RJ-45 RJ-45
Programmer HPR 100 HPR 100
Programming Display / OSD Display / OSD
Output RF connectors Female F connector Female F connector
Output level (dBμV) 81±2 81±2
Regulation margin (dB) 15 15
Output channels C2-C69 C2-C69
Type of modulator VSB / STEREO VSB / STEREO
Video S/N relation (dB) >54 >54
MIX loss (dB) <1 <1
Modulation standard B-G, D-K,L, I B-G, D-K,L, I
Spurious level (dBc) -60 -60
Conditional access No Yes, 1 slot
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Weight (g) 1.400 1.400
Consumption 5V (mA) <850 <850 + PCMCIA
Consumption 12V (mA) <400 <400
Consumption 30V (mA) <3 <3
Packaging 1 1
VSB TransmodulatorsHTAR series
COFDM inputWall mount/rack compatibleDigital compensation of the Output levelTelecontrolMade in Europe
HTAR 100 HTAR 100 CI
49
headends
Reference HSCT 100 HS2CT 100
Code 20020.11 20022.11
Description Transmodulator DVB-S --> DVB-C Transmodulator DVB-S2 --> DVB-C
Standard QPSK 8-PSK, QPSK
Input frequency range (MHz) 950-2150 950-2150
Input level (dBm) -30 to -60 -30 to -60
Loss in LOOP (dB) <1 <1
FEC 1/2, 2/3,3/4,5/6,7/8, 8/9, 9/10, 1/4, 1/3,1/5, 2/5, 3/5, 4/5 DVB RS 204,188
1/2, 2/3,3/4,5/6,7/8, 8/9, 9/10, 1/4, 1/3,1/5, 2/5, 3/5, 4/5 DVB RS 204,188
Input symbol speed (MS/s) DVS-S: 4-30 DVB-S: 1-45; DVB-S2: 1-37
Data processing EN 300 429 EN 300 429
Services/programs fi ltering - Programmable
Modulation error rate (MER) (dB) Typ. 40 /Min. 36 Typ. 40 /Min. 36
Selectable format of output modulation 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Output symbol speed (MS/s) 1 - 6,96 1 - 6,96
Roll-Off factor (%) 13, 15 13, 15
Selectable output channel (MHz) 47-862 47-862
Output level (dBμV) 80 80
Attenuator (dB) 15 15
MIX loss (dB) <1 <1
Spurious level (dBc) -60 -60
Input RF connector Female F connector Female F connector
Output RF connector Female F connector Female F connector
Programming interface RJ-45 RJ-45
Programmer HPR 100 HPR 100
Conditional access No No
Working temperature (ºC) 0 to 45 0 to 45
Consumption 5V (mA) 650 800
Consumption 12V (mA) 300 300
Consumption 24V (mA) 15 15
Consumption 30V (mA) 2 2
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Weight (g) 1.400 1.400
Packaging 1 1
Transmodulators100 series
8PSK input QPSK inputWall mount/rack compatibleDigital compensation of the Output levelTelecontrolMade in Europe
HSCT 100 HS2CT 100
50
headends
Reference HSTT 100
Code 20024.11
Description Transmodulator DVB-S --> DVB-T
Standard QPSK
Input frequency range (MHz) 950-2150
Loss in LOOP (dB) <1
FEC 1/2, 2/3,3/4,5/6,7/8, 8/9, 9/10, 1/4, 1/3, 1/5, 2/5, 3/5, 4/5 DVB RS 204,188
Input level (dBm) -30 to -60
Input symbol speed (MS/s) DVB-S: 4-30
Data processing EN 300 429
Services/programs fi ltering Programmable
Modulation error rate (MER) (dB) Typ. 38 /Min. 36
Selectable format of output modulation DVB-T / DVB-H
Bandwidth (MHz) DVB-T: 6/7/8 - DVB-H: 5/6/7/8
Reception mode DVB-T: 2K - 8 K - DVB-H: 2K - 4K - 8K
Selectable output channel (MHz) 47-862
Output level (dBμV) 80
Attenuator (dB) 15
MIX loss (dB) <1
Spurious level (dBc) -60
Input RF connector Female F connector
Output RF connector Female F connector
Programming interface RJ-45
Programmer HPR 100
Conditional access No
Working temperature (ºC) 0 to 45
Consumption 5V (mA) 650
Consumption 12V (mA) 300
Consumption 24V (mA) 15
Consumption 30V (mA) 2
Dimensions (mm) 75 x 265 x 150
Weight (g) 1.400
Packaging 1
Transmodulators100 series
QPSK inputWall mount/rack compatibleDigital compensation of the Output levelTelecontrolMade in Europe
HSTT 100
51
headends
Reference HAVM 100
Code 20044.11
Description 2 x A/V --> 2 x PAL BLV
Input TV system CVBS base band
Input level video (Vpp) 1
Input impedance () 75
Audio input impedance () 56
SNR >54
Modulation standard B-G, D-K,L,I
Spurious level (dBc) <-60
Selectable output frequency (MHz) 47-862
Output level (dBμV) 81±2
Attenuator (dB) 15
MIX loss (dB) <1
Power supply voltage (VDC) From HPS 100
Consumption 5 V (mA) 550
Consumption 12 V (mA) 550
Consumption 24 V (mA) -
Consumption 30 V (mA) 5
Working temperature (ºC) 0 to 45
Video connector 2 x female RCA
Audio connector 4 x female RCA
TV output RF loop connector 2 x female F
Programming interface RJ-45
Dimensions (mm) 75 x 265 x 150
Packaging 1
Headend Modulator100 series
CVBS base band inputWall mount/rack compatibleDigital compensation of the Output levelTelecontrolMade in Europe
HAVM 100
52
headends
Reference HTTR 100
Code 20028.11
Description DVB-T --> DVB-T
Standard COFDM
Input frequency range (MHz) 47-862
Loss in LOOP (dB) <1
Bandwidth (MHz) DVB-T (7-8)
Guard interval 1/4, 1/8, 1/16, 1/32
Reception mode DVB-T (2K,8K)
Input level (dBμV) 32-90
Modulation 16 QAM, 32 QAM, 64 QAM,128 QAM, 256 QAM
Data processing EN 300 429
Services/programs fi ltering Programmable
Modulation error rate (MER) (dB) Typ. 38 /Min. 36
Selectable format of output modulation DVB-T / DVB-H
Bandwidth (MHz) DVB-T: 6/7/8 - DVB-H: 5/6/7/8
Reception mode DVB-T: 2K - 8 K* - DVB-H: 2K - 4K - 8K
Selectable output frequency (MHz) 47-862
Output level (dBμV) 80
Attenuator (dB) 15
MIX loss (dB) <1
Spurious level (dBc) -60
Input RF connector Female F connector
Output RF connector Female F connector
Programming interface RJ-45
Programmer HPR 100
Conditional access No
Working temperature (ºC) 0 to 45
Consumption 5V (mA) 650
Consumption 12V (mA) 300
Consumption 24V (mA) 15
Consumption 30V (mA) 2
Dimensions (mm) 75 x 265 x 150
Weight (g) 1.400
Packaging 1
COFDM input
Processors and regenerators100 series
Wall mount/rack compatibleDigital compensation of the Output levelTelecontrolMade in Europe
HTTR 100
53
headends
Reference HCCR 100Code 20026.11
Description DVB-C --> DVB-C
Input frequency range (MHz) 50 - 858
Input Level (dBμV) 42 - 82
Bandwidth (MHz) 8
Symbol speed (MS/s) 1,9 - 6,9
Services/programs fi ltering Up to 8
Loss in LOOP (dB) <1
Input impedance () 75
Modulation QAM
Data processing EN 300 429
Modulation error rate (MER) (dB) Typ. 40 /Min. 36
Output symbol speed (MS/s) 1 - 6,96
Roll-Off factor (%) 13, 15
Selectable output frequency (MHz) 47-862
Output level (dBμV) 80
Attenuator (dB) 15
MIX loss (dB) <1
Spurious level (dBc) -60
Input RF connector Female F connector
Output RF connector Female F connector
Programming interface RJ-45
Programmer HPR 100
Conditional access No
Working temperature (ºC) 0 to 45
Consumption 5V (mA) 650
Consumption 12V (mA) 300
Consumption 24V (mA) 15
Consumption 30V (mA) 2
Dimensions (mm) 75 x 265 x 150
Weight (g) 1.400
Packaging 1
QAM input
Processors and regenerators100 series
Wall mount/rack compatibleDigital compensation of the Output levelError correctionTelecontrolMade in Europe
HCCR 100
54
headends
Reference HAM 100 HAMP 100
Code 20012.11 20042.11
Inputs / Outputs 4 / 1 1 / 1
Frequency range (MHz) 47-862 47-862
Gain (dB) 19 45
Attenuator (dB) 10 20
Line equalizer (dB) - 10
Output level (dBμV) IMD3 DIN 45004B 114 125
RF connector (input/output) F female / F female F female / F female
Consumption 24V (mA) 250 525
Power supply From HPS 100 95-230 VAC / 50Hz
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Packaging 1 1
Reference HPS 100 HPSR 100*
Code 20008.11 20010.11
Input voltage (50/60 Hz) 95-230 VAC / 50-60Hz 95-230 VAC / 50-60Hz
Output voltage (V) 5 / 12 / 24 / 30 5 / 12 / 24 / 30
Maximum capacity 6 modules 100 series 6 modules 100 series
Working temperature (ºC) 0 to 45 0 to 45
Dimensions (mm) 75 x 265 x 150 75 x 265 x 150
Packaging 1 1
Amplifi er and active combiner100 series
Power Supplies100 series
Amplifi ers Power supplies Wall mount/rack compatibleMade in Europe
* To be assembled in rack
HPS 100 HPSR 100
55
headends
Reference HFRR 100 HFRW 100
Code 20016.11 20014.11
Description Frame for 6 modules Frame for 7 modules
Dimensions (mm) For rack 19” 530 x 275 x 17
Packaging 1 1
Frames100 series
Accessories
Reference HPR 100
Code 20018.11
Description Programmer for headends
Features Protocol I2CDisplay 20x4 charactersDB-9 male connector, RJ45Memory card SD (FAT 16 format)Max. capacity: 2 GBUpgradeable through SD & RS-232Power supply (V): 12-14Consumption (mA): 20
Packaging 1
Programmer100 series
HPR 100
HFRR 100 HFRW 100
Made in Europe
multiswitch
accessories
57
Splitters ...................................58Sockets ...................................58Security cameras .....................59Camera diplexer ......................60
58
accessories
Reference SV 200F SV 300F SV 400F SV 600F SV 800F
Code 01190.19 01180.19 01191.19 01192.19 01193.19
Outputs 2 3 4 6 8
Distribution loss (dB)
5-40 MHz 3,5 6,5 7 10 11,6
40-1000 MHz 4 7 8 11 12
1000-2050 MHz 5 8,5 9 12,5 15
2050-2400 MHz 6 9,5 10 14 16,6
Isolation (dB)
5-40 MHz 28 25 30 25 28
40-1000 MHz 28 25 28 25 25
1000-2050 MHz 29 25 22 25 25
2050-2400 MHz 26 24 24 25 25
Return loss (dB)
5-40 MHz 17 17 12 11 15
40-1000 MHz 20 18 18 17 17
1000-2050 MHz 20 15 20 17 17
2050-2400 MHz 15 18 20 17 17
Packaging 5 5 5 2 2
Reference SAT 300 EAS SAT 310 DAS CAP 300 AAR 300
Code 01513.11 01514.11 01547.19 01549.19
Description Antenna socketwith integrated diplexer SAT/TV
Antenna loop-through socket
White cover platefor flush mounting
White mounting basefor surface mounting
Frequency (MHz) IN-TV: 5,70 / 120-862IN-R: 87,5 - 108IN-SAT: 950-2300
IN-OUT: 5-2400IN-TV: 5-70 / 120-862IN-R: 87,5 - 108IN-SAT: 950 - 2300
Pass Attenuationfrequency (dB)
Final 5-300: 3.0300-862: 3.0950-2150: 3.2
TAP Attenuationfrequency (dB)
IN-TV: <3IN-R: <2IN-SAT: <2
IN-TV: <10IN-R: <10IN-SAT: <10
Power pass SAT SAT/OUT
Type of connectors TV: IEC M/R: IEC H/SAT:F TV: IEC M/R: IEC H/SAT:F
SplittersSV series
Outlets, covers and accessories
Splitters Sockets
SV 200 F
SAT 300 EAS SAT 310 DASSingle socket Loop-through socket CAP 300 AAR 300
SV 300 F SV 400 F SV 600 F
59
accessories
Security System
Reference CAM 400 C-MOS IR CAM 600 color CCD
Code 01881.11 01883.11
Video signal PAL-G (b/w) PAL-G (color)
CCD sensor 1/4 Zoll C-MOS 1/3 CCD chip
Resolution 352x288 542x582
Photo-sensivity <0,15 Lux <0,15 Lux
Signal to noise ratio (dB) >50 >50
Lens F 2.8 / 3.8 mm F 2.8 / 3.8 mm
Aperture 45º h / 38º V 50º h / 40º V
System PAL-G / I / K PAL-G / I / K
Channel 21-69 tunable via rotary switch 21-69 tunable via rotary switch
Frequency range (MHz) 470-860 470-860
Video output level (dBμV) 95 +/-5 95 +/-5
Video moldulation 80 +/10% 80 +/-10%
Video S/N 45 dB min. 45 dB min.
Video bandwidth 0,5 MHz - 5,0 MHz 0,5 MHz - 5,0 MHz
Audio modulation 90 KHz +/-15% 90 KHz +/-15%
Audio carrier frequency of the 5,5 MHz G +/-3 KHz 5,5 MHz G +/-3 KHz
modulator programmable 6,0 MHz I +/-3 KHz6,5 MHz K +/-3 KHz
6,0 MHz I +/-3 KHz6,5 MHz K +/-3 KHz
Power supply 12 V / <250 mA 12 V / <200 mA
Test-pattern generator Video Video
Programming Rotary switch Rotary switch
Channel display Acc. to rotary switch Acc. to rotary switch
Temperature range -20 / +70ºC -20 / +70ºC
Security cameras with A/V modulatorCAM series
CAM 400 C MOS IR
accessories
60
Security System
- Offers the possibility of connecting two cameras, 2 x 250 mA max.- Power supply via coaxial connecting cable- Looping into existing antenna installation- Amplification of the camera signal adjustable 0 to 3 dB- Variable attenuator -18 dB, through loss <2dB- Power supply unit 230 V / 50 Hz /10 VA
- Ready to connect 4 cameras with RF-modulator- Standard TV set to be used as a monitor- Consecutive switching of camera view via 1 UHF TV channel- Fixed camera view via 4 UHF TV channels- Simple feed-in in existing antenna distribution system- Camera supply voltage fed through the coaxial cable
Camera feed in diplexer
4 way camera diplexer
CEW 1880 - Code: 01880.11
CEW 1884 - Code: 01884.11
CEW 1880
CEW 1884
accessories
Security System
The CEW 1884 provides the possibility to show the camera-view in a consecutive switching ofapproximately 5 seconds. For that all connected cameras have to be tuned to the same RF-channel. A TV-set which is tuned to the designated RF-channels serves as monitor.The CEW 1884detects the number of connected cameras and adopts the consecutive switching. Thereby no gapsoccur in case less than 4 cameras are connected. The CEW 1884 can likewise transfer thecamera signals continously. Therefore the 4 cameras must be tuned to 4 different RF channels.A gap of one to two channels should be provided to prevent disturbances. The sound will besupplied as well.
CEW 1884
61
AV 80/402
DistributionSystem
Index of references
63
Code Reference Page
01549.19 AAR 300 58
07002.11 ACS 17x16 30
07001.11 ACS 17x16 K 29
07004.11 ACS 17x32 30
07003.11 ACS 17x32 K 29
01182.11 ACS 7000 28
01181.11 ASV 502 26
01179.11 ASV 503 26
01199.11 ASV 902 26
01180.11 ASV 903 26
06011.11 AV 60/131 32
06012.11 AV 60/132 32
06013.11 AV 60/200 32
06061.11 AV 60/300 32
06060.11 AV 60/331 32
06071.11 AV 60/342 32
08380.11 AV 80/401 33
08381.11 AV 80/402 33
08390.11 AV 90/501 33
08391.11 AV 90/502 33
08300 BI B1F 33
08300 B3 B3F 33
08300 B4 B4F 33
08300 B5 B5F 33
08422.11 BKV 22/30 34
08423.11 BKV 22/65 34
08409.11 BKV 30/200F 34
08430.12 BKV 30/300F 34
08432.11 BKV 32/30 35
08433.11 BKV 32/65 35
08437.11 BKV 42/30 35
08438.11 BKV 42/65 35
01881.11 CAM 400 C-MOS 59
01883.11 CAM 600 color CCD 59
01547.19 CAP 300 58
01880.11 CEW 1880 60
01884.11 CEW 1884 60
08300 DAB DAB F 33
01725.11 DK 17 V 21
01723.11 DK 17x12 20
01718.11 DK 17x12 K 19
01724.11 DK 17x16 20
01719.11 DK 17x16 K 19
01730.11 DK 17x24 20
01728.11 DK 17x24 K 19
01731.11 DK 17x32 20
01729.11 DK 17x32 K 19
01722.11 DK 17x8 20
References by alphabetical Order
Code Reference Page
01717.11 DK 17x8 K 19
08300 FM FMF 33
20012.11 HAM 100 54
20042.11 HAMP 100 54
20044.11 HAVM 100 51
20026.11 HCCR 100 53
20038.11 HCIP 100 46
20040.11 HCIP 100 CI 46
20016.11 HFRR 100 55
20014.11 HFRW 100 55
20018.11 HPR 100 55
20008.11 HPS 100 54
20010.11 HPSR 100 54
20022.11 HS2CT 100 49
20000.11 HSAR 100 47
20002.11 HSAR 100 CI 47
20020.11 HSCT 100 49
20032.11 HSIP 100 44
20036.11 HSIP 100 CI 44
20024.11 HSTT 100 50
20004.11 HTAR 100 48
20006.11 HTAR 100 CI 48
20030.11 HTIP 100 45
20034.11 HTIP 100 CI 45
20028.11 HTTR 100 52
01688.11 KAD 22 V 17
05775.11 KAD 9x12 16
05772.11 KAD 9x12 K 15
05779.11 KAD 9x16 16
05773.11 KAD 9x16 K 15
05730.11 KAD 9x24 16
05720.11 KAD 9x24 K 15
05731.11 KAD 9x32 16
05721.11 KAD 9x32 K 15
05778.11 KAD 9x8 16
05771.11 KAD 9x8 K 15
01477.11 KAS 20 NV 9
01469.11 KAS 20 VV 9
01474.11 KAS 5x4 8
01476.11 KAS 5x6 8
01470.11 KAS 5x6 K 7
01478.11 KAS 5x8 8
01471.11 KAS 5x8 K 7
0001000 MDL 100 40
0001001 MDL 200 40
0001002 MDL 300 40
0001003 MDL 400 40
Index of references
Code Reference Page
0001004 MDX 500 42
0001006 MDX 600 42
01182.11 MT 0512 27
01183.11 MT 0518 27
01184.11 MT 0524 27
01185.11 MT 0912 27
01186.11 MT 0918 27
01187.11 MT 0924 27
02712.11 OLS 17x12 N 6
02716.11 OLS 17x16 N 6
02708.11 OLS 17x8 N 6
02512.11 OLS 5x12 N 5
02516.11 OLS 5x16 N 5
02504.11 OLS 5x4 N 5
02506.11 OLS 5x6 N 5
02508.11 OLS 5x8 N 5
02912.11 OLS 9x12 N 5
02912.11 OLS 9x16 N 5
02904.11 OLS 9x4 N 5
02906.11 OLS 9x6 N 5
02908.11 OLS 9x8 N 5
02762.11 OLY 17x12 14
02751.11 OLY 17x12 K 13
02763.11 OLY 17x16 14
02752.11 OLY 17x16 K 13
02764.11 OLY 17x24 14
02753.11 OLY 17x24 K 13
02765.11 OLY 17x32 14
02754.11 OLY 17x32 K 13
02761.11 OLY 17x8 14
02750.11 OLY 17x8 K 13
01508.11 OLY 9x12 11
01510.11 OLY 9x12 K 10
01509.11 OLY 9x16 11
01511.11 OLY 9x16 K 10
01503.11 OLY 9x4 11
01500.11 OLY 9x4 K 10
01504.11 OLY 9x8 11
01502.11 OLY 9x8 K 10
01507.11 OLY D9 KV 12
05507.11 PLU 9A 12
05506.11 PLU 9E 12
01513.11 SAT 300 EAS 58
01514.11 SAT 310 DAS 58
01723.11 SEM 17x12 N 4
Code Reference Page
01724.11 SEM 17x16 N 4
01726.11 SEM 17x24 N 4
01727.11 SEM 17x32 N 4
01722.11 SEM 17x8 N 4
01297.11 SEM 5x12 N 2
01298.11 SEM 5x16 N 2
01280.11 SEM 5x24 N 2
01281.11 SEM 5x32 N 2
01249.11 SEM 5x4 N 2
01279.11 SEM 5x6 N 2
01289.11 SEM 5x8 N 2
09012.11 SEM 9x12 N 3
09016.11 SEM 9x16 N 3
09024.11 SEM 9x24 N 3
09032.11 SEM 9x32 N 3
09004.11 SEM 9x4 N 3
09006.11 SEM 9x6 N 3
09008.11 SEM 9x8 N 3
01213.11 SEV 1213 36
01207.11 SLV 40 AN 36
01240.11 SLV 40 VV 36
01227.11 STV 1227 NV 36
01228.11 STV 1228 VV 36
01190.19 SV 200F 58
01180.19 SV 300F 58
01191.19 SV 400F 58
01192.19 SV 600F 58
01193.19 SV 800F 58
51004.11 UCS 51440 23
51000.11 UCS 51820 22
51001.11 UCS 51840 23
51002.11 UCS 52420 22
51003.11 UCS 52440 23
91004.11 UCS 91440 25
91000.11 UCS 91820 24
91001.11 UCS 91840 25
91002.11 UCS 92420 24
91003.11 UCS 92440 25
64
66
67
BCN Distribuciones, S.A.Zweigniederlassung Deutschland
Auf der Höhe 8D-44536 Lünen
Tel. +49 231 8785 01Fax +49 231 8785 200