ISSUING OFFICE: NO DESCRIPTION DATE PROJECT NO: KEY PLAN 6 5 4 3 2 1 6 5 4 3 2 1 A B C D E LAS CRUCES 8918.17 1 THIS DOCUMENT IS RELEASED ON JUNE 22, 2018 FOR THE PURPOSE OF INTERIM REVIEW UNDER THE AUTHORITY OF MICHAEL THOMAS STILLS, R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO BE USED FOR REGULATORY APPROVAL, CONSTRUCTION, BIDDING OR PERMIT PURPOSES. PARKHILL, SMITH & COOPER, INC. G-001 SET NUMBER: LAS CRUCES ACADEMIC CAMPUS HOUSING RENOVATIONS NEW MEXICO STATE UNIVERSITY SHEET INDEX GENERAL G-001 COVER SHEET, INDEX & GENERAL CONSTRUCTION INFORMATION G-002 SYMBOLS, LEGENDS & ABBREVIATIONS G-003 ACCESSIBILITY STANDARDS 79, 80, 185 RHODES GARRETT HAMIEL HALL RGH A-101 DEMOLITION PLAN - FIRST FLOOR RGH A-102 DEMOLITION PLAN - SECOND FLOOR RGH A-103 DEMOLITION ROOF PLAN RGH A-104 REFLECTED CEILING PLAN - FIRST FLOOR RGH A-105 ENLARGED PLANS AND INTERIOR FLOOR FINISHES RGH A-106 ROOF DETAILS RGH A-401 SCHEDULES RGH A-510 ROOF DETAILS INTERIOR FINISHES I-001 ABBREVIATIONS & FINISH LEGEND I-401 FLOOR AND WALL FINISH PLAN LAS CRUCES, NEW MEXICO 88003 PACKAGE 2 (50% Construction Docs) GENERAL CONSTRUCTION INFORMATION BUILDING IBC 2018 PLUMBING UPC 2012 MECHANICAL UMC 2012 ELECTRICAL NEC 2014 FIRE IFC 2018 ENERGY 2009 IECC ACCESSIBILITY IBC 2015, CH. 11; ICC/ANSI A117.1-2009 APPLICABLE CODES ALTERNATE NO. 1 ALTERNATE NO. 2 ALTERNATE NO. 3 ALTERNATE NO. 4 ALTERNATES LIST FOR RHODES GARRETT HAMIEL HALL (79, 80,185)

Upload: dinhminh

Post on 22-Mar-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

G-001SET NUMBER:

LAS CRUCES ACADEMIC CAMPUS

HOUSING RENOVATIONSNEW MEXICO STATE UNIVERSITY

SHEET INDEX

GENERAL

G-001COVER SHEET, INDEX & GENERAL CONSTRUCTION INFORMATION

G-002SYMBOLS, LEGENDS & ABBREVIATIONS

G-003 ACCESSIBILITY STANDARDS

79, 80,

185

RHODES GARRETT HAMIEL HALL

RGH A-101 DEMOLITION PLAN - FIRST FLOOR

RGH A-102 DEMOLITION PLAN - SECOND FLOOR

RGH A-103 DEMOLITION ROOF PLAN

RGH A-104 REFLECTED CEILING PLAN - FIRST FLOOR

RGH A-105 ENLARGED PLANS AND INTERIOR FLOOR FINISHES

RGH A-106 ROOF DETAILS

RGH A-401 SCHEDULES

RGH A-510 ROOF DETAILS

INTERIOR FINISHES

I-001 ABBREVIATIONS & FINISH LEGEND

I-401 FLOOR AND WALL FINISH PLAN

LAS CRUCES, NEW MEXICO 88003

PACKAGE 2 (50% Construction Docs)

GENERAL CONSTRUCTION INFORMATION

BUILDING IBC 2018

PLUMBING UPC 2012

MECHANICAL UMC 2012

ELECTRICAL NEC 2014

FIRE IFC 2018

ENERGY 2009 IECC

ACCESSIBILITYIBC 2015, CH. 11; ICC/ANSI A117.1-2009

APPLICABLE CODES

ALTERNATE NO. 1

ALTERNATE NO. 2

ALTERNATE NO. 3

ALTERNATE NO. 4

ALTERNATES LIST

FOR

RHODES GARRETT HAMIEL HALL (79, 80,185)

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

G-002

AA00

CL

99.6

99.6

X X

320.10 TC

319.60 G

319.60

+TC

+G

+FL

WP

A

x

3

1

9

.

6

0

DS

FD

RD

OD

CJ

S

MCJ

GENERAL DRAWING LEGEND FLOOR PLAN LEGENDSITE PLAN LEGEND ROOF PLAN LEGEND RCP LEGEND DETAIL LEGENDABBREVIATIONS

SD

SHEET TYPE DESIGNATORS

AANNNSHEET IDENTIFICATION FORMAT

0 GENERAL (COVER SHEETS, INDEX, SYMBOLS LEGEND, NOTES, ETC.)

1 PLANS (HORIZONTAL VIEWS)

2 ELEVATIONS (VERTICAL VIEWS)

3 SECTIONS (SECTIONAL VIEWS)

4 LARGE SCALE VIEWS (ENLARGED PLANS, ELEVATIONS, OR SECTIONS

THAT ARE NOT DETAILS)

5 DETAILS

6 SCHEDULES AND DIAGRAMS

7 USER DEFINED (FOR TYPES THAT DO NOT FALL IN OTHER CATEGORIES

OR STANDARD DETAILS)

8 USER DEFINED (FOR TYPES THAT DO NOT FALL IN OTHER CATEGORIES)

9 3D REPRESENTATIONS (ISOMETRICS, PERSPECTIVES, PHOTOGRAPHS)

SHEET TYPE

DESIGNATOR

(SEE BELOW)

DISCIPLINE

DESIGNATOR

SHEET SEQUENCE

NUMBER

ROOM NAME

ROOM NUMBER

DOOR NUMBER

WINDOW MARK

EQUIPMENT

LOUVER MARK

HOLLOW METAL FRAME

MARK

ALUMINUM FRAME MARK

KEY NOTE

KEY NOTE-DEMOLITION

PARTITION TYPE

DISPLAY BOARD

REVISION

STRUCTURAL COLUMN

LINE

DATUM ELEVATION

(EXISTING)

DATUM ELEVATION

(NEW)

BREAK LINE

CENTER LINE

SHEET NUMBER WHERE REFERENCED

REFERENCE NUMBER

DRAWING BLOCK TITLE

PLAN DETAIL MARK

SECTION MARK

ELEVATION MARK

NORTH ARROW

NORTH ARROW FOR

SITE PLANS

EXISTING DOOR

NEW DOOR

MATCH/DIVIDE LINE

PROPERTY LINE

EXISTING

CONSTRUCTION TO

REMAIN

EXISTING

CONSTRUCTION TO BE

REMOVED

PROPERTY LINE

FENCE

NEW ASPHALT PAVING

NEW CONCRETE

WALK/PAVING

NEW CONTROL JOINT

NEW EXPANSION JOINT

NEW CONTOUR LINES

EXISTING CONTOUR

LINES TO REMAIN

NEW SPOT ELEVATION

EXISTING SPOT

ELEVATION

TOP OF CURB

GUTTER

FLOW LINE

WORKING POINT

ACCESSIBLE PARKING

SIGN

PARKING SIGN

LIGHT POLE

TREE

SLOPE

FLOOR DRAIN

DOWN SPOUT

FURNITURE/EQUIPMENT

NIC

FIRE EXTINGUISHER AND

BRACKET

FIRE EXTINGUISHER AND

CABINET

HANDRAIL

WALL GUARD

END WALL GUARD

CORNER GUARD

WIRE MESH OR FABRIC

PARTITION

GLAZING SYSTEM

NEW PARTIAL HEIGHT

WALLS

NEW METAL STUD

WALLS

EXISTING

CONSTRUCTION TO BE

REMOVED

EXISTING

CONSTRUCTION TO

REMAIN

MASONRY CONTROL

JOINT

CMU WALL

FACE BRICK

CONCRETE WALL ROOF DRAIN

OVERFLOW DRAIN

SLOPE

MECHANICAL

EQUIPMENT

VENT THROUGH ROOF

(VTR)

SKYLIGHT

ROOF HATCH

SMOKE DETECTOR

ACCESS PANEL

SPEAKER

CONTROL JOINT

CEILING TRACK

SKYLIGHT

LIGHT FIXTURES

EXIT LIGHTS

RETURN AIR OR

EXHAUST GRILLE

SUPPLY AIR GRILLE

LAY-IN CEILING PANEL

LAY-IN CEILING PANEL

SUSPENDED METAL

LATH AND PLASTER

CEILING

GYP BD CEILING COMPACTED SOIL

UNDISTURBED SOIL

STONE/MARBLE

PLASTER OR STUCCO

ON METAL LATH

STEEL

CONCRETE IN SECTION

BRICK

CMU

BATT INSULATION

ACOUSTICAL TILE

RIGID INSULATION

WOOD CONTINUOUS

WOOD DISCONTINUOUS

PLASTER, SAND OR

CEMENT GROUT

POUROUS FILL, GRAVEL

(CAPILLARY WATER

BARRIER PAVEMENT BASE)

TERRAZZO (IN SECTION)

ROOM NAME

000

000

00

00

LV00

HM00

AL00

00

00

00

0

NORTH

N

A1/G-001

A1/G-001

A1/G-001

/

A1

TITLE

1/8"=1'-0"

FEB

FEC

A

ACC ACCESSIBLE

AB ANCHOR BOLT

ACI AMERICAN CONCRETE INSTITUTE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADDL ADDITIONAL

ADJ ADJUSTABLE

ADDM ADDENDUM

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APA AMERICAN PLYWOOD ASSOCIATION

APPROX APPROXIMATE

ARCH ARCHITECT

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

ASTM AMERICAN SOCIETY OF TESTING MATERIALS

AUTO AUTOMATIC

AVG AVERAGE

AWG AMERICAN WIRE GAGE

AWS AMERICAN WELDING SOCIETY

A/C AIR CONDITIONING

B

BAL BALANCE

BC BACK OF CURB

BIA BRICK INSTITUTE OF AMERICA

BITUM BITUMINOUS

BL BUILDING LINE

BLDG BUILDING

BM BENCH MARK

BOCA BUILDING OFFICIALS AND CODE ADMINISTRATORS

INTERNATIONAL, INC

BOS BOTTOM OF STEEL

BOT BOTTOM (BOTTOM FACE, LAYER, SIDE)

B PL BASE PLATE

BRDG BRIDGING

BRG BEARING

BTWN BETWEEN

BUR BUILT-UP ROOFING

C

C AMERICAN STANDARD CHANNEL (STRUCTURAL

SHAPE)

CU FT CUBIC FOOT

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CG CORNER GUARD

CI CAST IRON

CIR CIRCLE

CIRC CIRCULAR

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

cm CENTIMETER

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

CRCMF CIRCUMFERENCE

CSK COUNTER SUNK

CSI CONSTRUCTION SPECIFICATIONS INSTITUTE

CTR CENTER

CU YD CUBIC YARD

D

D DEPTH

DAT DATUM

DBL DOUBLE

DDS DOUBLE DISPLAY STRIP

DEG DEGREE

DEMO DEMOLISH

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIV DIVIDE

DL DEAD LOAD

DS DOWNSPOUT

DWG DRAWING

E

E EAST, MODULUS OF ELASTICITY

EA EACH

EF EACH FACE, EXTERIOR FINISH

EIFS EXTERIOR INSULATION FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

ENGR ENGINEER

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXP EXPANSION

EXP BT EXPANSION BOLT

EXT EXTERIOR

F

FD FLOOR DRAIN

FDTN FOUNDATION

FEB FIRE EXTINGUISHER & BRACKET

FEC FIRE EXTINGUISHER & CABINET

FF EL FINISH FLOOR ELEVATION

FIN FLR FINISH FLOOR

FIN FINISH(ED)

FOC FACE OF CONCRETE, FACE OF CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUD

FOW FACE OF WALL

FS FAR SIDE (FACE, LAYER)

FT FOOT

FTG FOOTING

FURG FURRING

G

GA GAGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GOVT GOVERNMENT

GYP BD GYPSUM BOARD

GYP GYPSUM

H

HDBD HARDBOARD

HDWD HARDWOOD

HDW HARDWARE

HEX HEXAGON(AL)

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HEAT PUMP

HS HIGH STRENGTH

HT HEIGHT

HVAC HEATING VENTILATION AND AIR CONDITIONING

I

I MOMENT OF INERTIA

IBC INTERNATIONAL BUILDING CODE

ID INSIDE DIAMETER

IF INSIDE FACE

INCL INCLUDE(D)(ING)(SIVE)

INS INSULATION

INT INTERIOR

INV INVERT(ED)

J

JAN JANITOR

L

l LITER

L ANGLE (STRUCTURAL SHAPE)

LB POUND

LH LEFT HAND

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LT LIGHT

LT WT LIGHT WEIGHT

M

MAU MAKE UP AIR UNIT(S)

m METER(S)

MATL MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MCJ MASONRY CONTROL JOINT

MECH MECHANIC(AL)

MFG MANUFACTURING

MFR MANUFACTURER

MIL STD MILITARY STANDARD

MIN MINIMUM

MISC MISCELLANEOUS

mm MILLIMETER

MO MASONRY OPENING

MOD MODIFY

MT METAL THRESHOLD

MTL METAL

MLWK MILLWORK

N

N NORTH

NA NOT APPLICABLE

NAT NATURAL

NBS NATIONAL BUREAU OF STANDARDS

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NS NEAR SIDE (FACE)

NTS NOT TO SCALE

O

OC ON CENTER

OD OUTSIDE DIAMETER

OF OUTSIDE FACE

OFD OVER FLOW DRAIN

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH DR OVERHEAD DOOR

OPNG OPENING

OPH OPPOSITE HAND

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINISTRATION

Oz OUNCE

P

PAR PARALLEL

PCA PORTLAND CEMENT ASSOCIATION

PCF POUNDS PER CUBIC FOOT

PCI PRESTRESSED CONCRETE INSTITUTE

PERF PERFORATE(D)

PERP PERPENDICULAR

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLF POUNDS PER LINEAL FOOT

PR PAIR

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PBD PARTICLE BOARD

PTD PAPER TOWEL DISPENSER

PTDWR PAPER TOWEL DISPENSER & WASTE RECEPTACLE

PVC POLYVINYL CHLORIDE

PLYWD PLYWOOD

PVG PAVING

Q

QC QUALITY CONTROL

QTY QUANTITY

R

R RADIUS

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFERENCE

REFL REFLECT

REINF REINFORCE

REQD REQUIRED

REV REVISION

RH RIGHT HAND(ED)

RO ROUGH OPENING

ROW RIGHT OF WAY

RTU ROOF TOP UNIT

S

S SOUTH

SBCCI SOUTHERN BUILDING CODE CONGRESS

INTERNATIONAL

SCHED SCHEDULE

SD SOAP DISPENSER

SDI STEEL DOOR INSTITUTE

SECT SECTION

SHT SHEET

SIM SIMILAR

SJI STEEL JOIST INSTITUTE

SPEC SPECIFICATION

SP SOLID PLASTIC

SST STAINLESS STEEL

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENDED

SYMM SYMMETRICAL

T

THD TREAD

TAN TANGENT

TEMP TEMPORARY

TFF TOP OF FINISH FLOOR

THK THICKNESS

TLT TOILET

TMH TOP OF MANHOLE

TOB TOP OF BEAM

TOC TOP OF CURB

TOF TOP OF FOOTING

TOG TOP OF GRADE

TOJ TOP OF JOIST

TOL TOLERANCE

TOM TOP OF MASONRY

TOS TOP OF STEEL

TOW TOP OF WALL

TTD TOILET TISSUE DISPENSER

TRANS TRANSPARENT

TRTD TREATED

TS TUBE STEEL

TYP TYPICAL

T&G TONGUE AND GROOVE

U

UBC UNIFORM BUILDING CODE

UL UNDERWRITERS LABORATORIES, INC.

ULT ULTIMATE

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

V

VAR VARIES

VERT VERTICAL

W

W WEST

WLD WELDED

WP WORK POINT

WWF WELDED WIRE FABRIC

W/ WITH

W/O WITHOUT

W/W WALL TO WALL

X

XFMR TRANSFORMER

DB00

A0

PLAN NORTH ARROW

PLAN NORTH

TRUE NORTH

FURNISHINGS

1/4

1

2

1/2

60" MIN

60 M

IN

30

MIN

24

MIN

12

MIN

30

MIN

12

MIN

60 MIN

48 MIN

30

MIN

FORWARD

PARALLEL

48 M

IN

30 MIN

30

M

IN

48 MIN

36 MIN

X >

24

60 MIN

X >

15

ELEVATION

TOE CLEARANCE

PLAN

CENTERED

30

M

IN

6 MAX

17-25

ELEVATION

KNEE CLEARANCE

8 MIN

9"

MIN

11 MIN

27 M

IN

4 MAX

X ≥ 80

X >

27

X <

80"

27

"

MA

X

48 M

AX

15

MIN

20

MAX

48 M

AX

44

M

AX

2O-25

MAX

10 MAX

48 M

AX

15

MIN

34

M

AX

10 MAX

48 M

AX

34

M

AX

>10-24

MAX

46 M

AX

24

MAX 48 MIN

24

MAX

32 M

IN

36 M

IN

32 M

IN

36 M

IN

Y

48 M

IN

X

42 MIN

X

42 MIN

X<48

CLEAR FLOOR AREA/ACCESSIBLE ROUTE

ALCOVE

FORWARD

ALCOVE

PARALLEL

180 DEG

TURN AROUND

NARROW

PASSAGE

SINGLE

WHEELCHAIR

T-SHAPE

TURN AROUND

CIRCLE

TURN AROUND

BEVELED TRANSITION

VERTICAL TRANSITION

PROTRUDING

OBJECT

UNDER STAIRS

FORWARD REACH RANGES SIDE REACH RANGES

PROTRUDING OBJECT PROTECTION/REACH RANGES

5 M

AX

15 M

IN

BACK WALL

BACK WALL

LENGTH

30

M

IN

30 M

IN

12 MIN

CO

NT

RO

L

EN

D W

ALL

24 M

IN

12 MAX 24 MAX24 MIN

12

M

IN

24 M

IN

12 MAX

15 MAX

12 MAX15 MAX12 MAX

24 MAX24 MIN

REMOVABLE SEAT CONTROLS LOCATION FIXED SEAT

REMOVABLE SEAT FIXED SEAT

CO

NT

RO

L

WA

LL

BACK

SE

AT

WA

LL

36

36

36

M

IN

48 MIN

SE

AT

60 MIN

30 M

IN

30

M

IN

36

36 MIN

60 MIN60 MIN

30 M

IN

30

M

IN

6 M

AX

6 MAX6 MAX

6 M

AX

6 MAX

6 MAX

6 M

AX

6 M

AX

6 MAX

TRANSFER SHOWER ROLL-IN SHOWER ROLL-IN SHOWER

W/ SEAT ROLL-IN SHOWER

W/ SEAT

ALTERNATE

38 M

IN

48 M

AX

15 MAX

BACK

WALL

CONTROL WALL

WITHOUT SEAT

CONTROL WALL

WITH SEAT

48 M

AX

27 MAX

48 M

AX

SHOWERS

8-10

17

-19

8-10

17-1

9

17-19

SHOWER SEAT

48

M

IN

33 MIN 33 MIN

60 M

IN

33 MIN 33 MIN

BENCH SEATING

THEATER SEATING

30 M

IN

24

M

IN

BENCH SEATING

THEATER SEATING

ASSEMBLY SEATING

LINE OF SIGHT

LINE OF SIGHT

SPORTS ARENA

THEATER/PLAYHOUSE

AUDITORIUM/CONCERT HALL

LECTURE HALLS

MEETING ROOMS

OF TUB

CO

NT

RO

L E

ND

W

ALL

HE

AD

E

ND

W

ALL

LENGTH

OF TUB

WA

LL/P

OS

T M

TD

CA

NT

ILE

VE

RE

D

UN

IT

FORWARD APPROACH

ACCESSIBLE UNIT

56 M

IN

59 M

IN

60 MIN60 MIN

4 MAX

42 M

IN

6 M

IN

6 MIN

42 M

IN

60 M

IN

35-37

ANY AMOUNT

X ≥ 80

X <

27

PROTRUDING

OBJECT

URINALS

NOTE:

WIDE SIDE

LEVER ON

36 MIN

TYPICAL WATER CLOSETS

33-36

250 LBS AND BE CONTINUOUS

GRAB BARS MUST SUPPORT

EWC/DRINKING FOUNTAINS

DOWN TO 27" AFF MIN

APRON THAT EXTENDS

HIGH UNIT SHOULD HAVE

15 MIN

CL

BRACKET MOUNTED

FIRE EXTINGUISHER

48

48

* CHALKBOARD MOUNTING

* MARKERBOARD MOUNTING

36 M

AX

9

ROOM

FIRE ALARM

AUDIBLE &

ACCESSIBLE

COAT HOOKS

VISUAL SIGNAL

60 M

AX

OUTLET

15 M

IN

80-96

48 M

AX

2 FROM

DOOR FRAME

48 M

AX

* TACKBOARD MOUNTING

CABINET

FIRE EXTINGUISHER

TOWELS

48 M

AX

MISC MOUNTING (DIMENSIONS SHOWN ARE TO THE HIGHEST OPERABLE PART)

STANDARD ACCESSIBLE MOUNTING HEIGHTS

TELEPHONE

THERMOSTAT

TOWELS

SWITCH

OUTLET

CUPS

SOAP

TO

P O

F E

XT

IN

GU

IS

HE

R

IN

SID

E O

F C

AB

IN

ET

TO

P O

F T

RA

Y

6

FIN CLG

IF CEILING IS BELOW 90"

MOUNT TOP OF SIGNAL DEVICE

6" BELOW FINISHED CEILING

NOTE:

17 MIN

EQUIPMENT PERMITTED

IN OUTLINED AREA

36 M

AX

28-34

38 M

AX

2 M

AX

WASHING MACHINE

TOP LOAD

CONVEYOR

GROCERY

SLIDE

TRAYACCESSIBLE

COAT HOOKS

AMBULATORY ACCESSIBLE TOE CLEARANCE SIDE APPROACH WALL HUNG WATER CLOSET FLOOR MTD WATER CLOSET

TYPICAL TOILET STALLS

CL

HE

AD

E

ND

(REQUIRED) (REQUIRED)

WA

LL

TUBS

CL

PUSH SIDE

48 M

IN

NOTE:

PULL SIDE

18 MIN

60 M

IN

X

FRONT APPROACHES SWINGING DOORS

HAS BOTH A CLOSER AND A LATCH

X = 12" MIN (305mm) IF DOOR

PUSH SIDE

Y

42 M

IN

PUSH SIDE

NOTE:

A CLOSER

PULL SIDE

A CLOSER

Y = 54" MIN (1370mm) IF DOOR HAS

NOTE:

PULL SIDE

NOTE: X = 36" MIN IF Y = 60";

X = 42" MIN IF Y = 54"

X

Y

Y

42 M

IN

HINGE SIDE APPROACHES SWINGING DOORS

LATCH SIDE APPROACHES SWINGING DOORS

Y = 48" MIN (1220mm) IF DOOR

22 MIN

HAS BOTH A CLOSER AND A LATCH

Y = 48" MIN IF DOOR HAS

Y

48 M

IN

24 MIN 24 MIN

NOTE:

VESTIBULE DOORS

TWO HINGED DOORS IN SERIES

NOTE:

THE CLEARANCES FOR FRONT APPROACHES

ALL DOORS IN ALCOVES SHALL COMPLY WITH

TYPICAL DOOR CLEARANCES

48 MIN

4

8

M

I

N

VESTIBULE DOORS

32 MIN

CLEAR

43 M

AX

34 M

IN

60 M

IN

18 MIN

X>

8

48 M

IN

12 MIN

X>

8

48 M

IN

RECESSED DOOR

DOOR HARDWARE DOOR LITE

CLOSER & LATCH PROVIDED

WALL

CL

GENERAL NOTES

ACCESSIBILITY GUIDELINE SHEETS ARE BASED ON

THE APPLICABLE ACCESSIBILITY STANDARDS

ADOPTED BY THE STATE OF NEW MEXICO; 2003 ICC

ANSI A117.1

ACCESSIBILITY GUIDELINE SHEETS ARE FOR

INFORMATIONAL PURPOSES ONLY. AND INTENDED

TO SERVE AS A GUIDE FOR CONSTRUCTION

PROFESSIONALS AND OWNERS.

SOME OF THE INFORMATION AND PICTOGRAPHS

SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT.

REFER TO PLUMBING SHEETS FOR PLUMBING

FIXTURE MOUNTING HEIGHTS.

GRAPHICS SHOWN ARE FOR ADULTS.

48 M

AX

27 MAX

17-19

CL

16-18

CL

16-18

CL

16-18

CL

16-18

CL

60 MIN

CLEARANCE AT WATER CLOSET

16-18

CL

56 M

IN

LAVATORY, URINAL

OR TOILET ACCESSORIES

NOT IN A STALL

12

MIN

24 MIN

15 MIN

CL

36

36

TO

S

HO

UL

DE

R

IF Y=60 MIN, X=36 MIN

33-36

LINE OF SIGHT OVER HEADS

CL

FRONT LOAD

15-36

IF A WALL HUNG OR FLOOR

MOUNTED FLUSH VALVE

WATER CLOSET IS SPECIFIED,

ENSURE ALL DIMENSIONS

SHOWN ARE MET.

EXAMPLE SIGNAGE - SEE STANDARD ACCESSIBLE MOUNTING HEIGHT

LETTERS & BRAILLE

GRAPHIC SYMBOLS

6x8 PICTOGRAM

6 M

IN

MEN

6x8 PICTOGRAM

GRAPHIC SYMBOLS

LETTERS & BRAILLE

6 M

IN

WOMEN

& BRAILLE

ROOM NUMBER

8x6 ROOM NAME

6 M

IN

129

SUPERVISOR

MAINTENANCE

& BRAILLE

10x3 ROOM NAME

ADMINISTRATION

6x6 DIRECTIONAL

GRAPHIC SYMBOL

ONLY ONLY

GRAPHIC SYMBOL

6x6 DIRECTIONAL

6 M

IN

& BRAILLE

6x6 CHANGEABLE

MESSAGE W/ PERMANENT

ROOM NAME, NUMBER,

ITHJOHN S

OFFICE

169

REFER TO SIGNAGE PACKAGE OR DETAILS FOR ACTUAL SIGNAGE SPECIFIED

6x8 PICTOGRAM

GRAPHIC SYMBOLS

LETTERS & BRAILLE

6 M

IN

STAIR 1

6x8 PICTOGRAM

GRAPHIC SYMBOLS

LETTERS & BRAILLE

6 M

IN

STAIR 1

48 M

IN

60 M

AX

6

0 M

AX

48

M

IN

6 M

IN

60

M

AX

48 M

IN

60 M

AX

48

M

IN

CL

DISPENSERS

36 MAX

12

MAX

54 MIN

42 MIN

33-36

TO

P O

F G

RIP

PIN

G

SU

RF

AC

E

7-9

48 M

AX

15 M

IN

100

48 M

IN

15

MIN

CL

30

MIN

X

36

MIN

IF X>24

15

MIN

CL

36

MIN

IF X>24

X

CL

LAVATORIES

36

MIN

IF X>24

X

REFER TO KNEE AND

TOE CLEARANCE GRAPHICS

CL

36 MIN

30

IF X ≤

24

X

15

MIN

CL

NOT ASSOCIATED

24 MIN

9"

MIN

15

MIN

CL

WITH A WATER CLOSET

ONLY TOILET

ASSOCIATED WITH

WATER CLOSETS ARE

ALLOWED WITHIN

FLOOR AREA

ACCESSORIES

CHANGES IN LEVELNOTE: REFER TO "CHANGES IN LEVEL" DETAILS FOR SHOWER THRESHOLDS

THRESHOLD

SEAT

SEAT

THRESHOLD THRESHOLD

1

2

1/4

VERTICAL/BEVELED

1/4

TRANSITION

43 M

AX

43 M

AX

48 M

AX

LIT

E

OP

EN

IN

G

SURFACE OF MIRROR

TOP OF REFLECTIVE

74 M

IN

BOTTOM OF

MIRROR

SURFACE OF

REFLECTIVE

40 M

AX

REFLECTIVE SURFACE

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

G-003

DEMOLITION NOTES

REMOVE EXISTING CONSTRUCTION AS INDICATED BY:00

1. NOT USED.

2. REMOVE RUBBER / VINYL STAIR TREAD AND RISERS IN ITS

ENTIRETY. PREPARE STEPS TO RECEIVE NEW FINISH.

3. REMOVE EXISTING 1X4 LIGHT FIXTURE THROUGHOUT THE

CORRIDORS, TYPICAL. REFER TO ELECTRICAL FOR ADDITIONAL

INFORMATION AND EXTEND OF WORK.

4. NOT USED.

5. -

6. -

7. REMOVE NON-COMPLIANT DOOR KNOB

NORTH

A1

DEMOLITION PLAN - 1ST FLOOR

RHODES HALL

1/8"=1'-0" -

A2

DEMOLITION PLAN - 1ST FLOOR

HAMIEL HALL

1/8"=1'-0" -

A4

DEMOLITION PLAN - 1ST FLOOR

GARRETT HALL

1/8"=1'-0" -

NORTH NORTH

RHODES GARRETT HAMIEL GENERAL NOTES

A. ALL WOOD TRIM / RAILING THROUGHOUT THE HALLWAYS AND FOYERS SHALL BE REFURBISHED AS PART OF THIS SCOPE.

B. EXISTING LAY-IN CEILING TILES, GRID AND 1X4 LIGHT FIXTURES IN CORRIDOR SHALL BE REMOVED AND REPLACED WITH NEW LED FIXTURES AS SPECIFIED. REFER TO

ELECTRICAL FOR SCOPE EXTENTS AND NEW FIXTURE LOCATIONS.

ALTERNATE No. 01 - MODIFY EXISTING FIRE SPRINKLER HEADS TO BE CONCEALED WITHIN THE CEILING WITH ESCUTCHEON FINISH.

C. ALL COMMUNITY RESTROOM TILED SURFACES SHALL RECEIVE "MIRACLE METHOD" TREATMENT. SURFACES INCLUDE TILE FLOOR AND 4'-0" HIGH WAINSCOT. ALL OTHER

NON-TILE SURFACES SHALL RECEIVE NEW PAINT FINISH AS SCHEDULED. REFER TO INTERIOR SHEETS.

D. ALL TILED SURFACES IN SUITE RESTROOMS SHALL RECEIVE "MIRACLE METHOD" TREATMENT. SURFACES INCLUDE BUT ARE NOT LIMITED TO THE ENTIRE FLOOR, RESTROOM

BASE AND THE SHOWER 7'-0" HIGH WAINSCOT WALLS. ALL OTHER SURFACES SHALL RECEIVE NEW PAINT FINISH AS SCHEDULED. REFER TO INTERIOR SHEETS.

E. ALL COMMUNITY SHOWER TILED SURFACES SHALL RECEIVE "MIRACLE METHOD" TREATMENT. SURFACES INCLUDE TILE FLOOR, 4'-0" HIGH WAINSCOT, FULL HEIGHT SHOWER

AND CHANGING STALL WALLS. ALL OTHER SURFACES SHALL RECEIVE NEW PAINT FINISH AS SCHEDULED. REFER TO INTERIOR SHEETS.

F. U.N.O. ALL EQUIPMENT AND FIXTURES SHALL REMAIN UNDISTURBED.

G. IN RESTROOMS WHERE THE "MIRACLE METHOD" WILL BE RECEIVED, EXISTING TOILETS WILL BE REMOVED PRIOR WORK AND REPLACED AT COMPLETION OF WORK.

8' 16'0 4' 8' 16'0 4' 8' 16'0 4'

LEGEND

CARPET

PAINT

WOOD TRIM / RAILING IN HALLWAY

B

B

B

B

B

A

B

C

B

A

B

C

B A

B A

B C

B C

02

08

1X4 RECESSED LIGHT FIXTURE

GENERAL NOTES

A. DOCUMENTS ARE BASED ON EXISTING FILES PROVIDED BY NMSU

AND ON FIELD OBSERVATIONS. PRIOR TO BEGINNING ANY

DEMOLITION WORK, MAKE A THOROUGH SURVEY OF THE

BUILDING AND NOTIFY THE ARCHITECT IN WRITING OF ALL

OBSERVED DISCREPANCIES BETWEEN THE EXISTING CONDITIONS

AND THOSE SHOWN ON THE DRAWINGS.

B. PROVIDE MEASURES TO PROTECT ALL MATERIAL AND

EQUIPMENT TO REMAIN DURING THE DURATION OF THE PROJECT.

C. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO THOSE

ITEMS NOTED. OTHER ITEMS OF MINOR NATURE MAY EXIST

WHICH ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS ARE

TO BE REMOVED AS NECESSARY TO PROVIDE ACCESS OR ALLOW

ALTERATIONS FOR THE NEW WORK TO PROCEED.

D. WHERE DEMOLITION EXPOSES SUBSTRATES WHICH WILL

RECEIVE NEW FINISH MATERIALS, PROPERLY REMOVE EXISTING

MATERIALS AS REQUIRED FOR NEW FINISHES.

E. PATCH AND REPAIR EXISTING ADJACENT TO MATCH WHERE

REQUIRED DUE TO DEMOLITION PROCEDURES.

F. OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL

IMPROVEMENTS REPLACED DURING CONSTRUCTION.

COORDINATE WITH OWNER PRIOR TO BEGINNING OF PROJECT

FOR ITEMS TO BE SALVAGED FOR OWNER USE.

G. CONTRACTOR SHALL DISPOSE OF MATERIAL IN A PROPER

MANNER AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION

AND IN ACCORDANCE WITH LOCAL AND STATE CODES AND

ORDINANCES.

A3/RGH A-401

E1/RGH A-401

A2/RGH A-401

A1/RGH A-401

NIC - NOT IN CONTRACT

ROOM

102

ROOM

101

ROOM

103

ROOM

104

ROOM

106

ROOM

105

ROOM

108

LOUNGE

107

SHOWER

150

RESTROOM

148

SHOWER / BATH

126

SHOWER

171

RESTROOM

173

LOUNGE

ROOM

110

ROOM

113

ROOM

114

LOUNGE

111

ROOM

116

ROOM

115

ROOM

117

ROOM

118

ROOM

120

ROOM

119

ROOM

184

ROOM

182

ROOM

180

ROOM

178

ROOM

176

ROOM

174

ROOM

172

ROOM

166

ROOM

164

ROOM

162

ROOM

160

ROOM

158

ROOM

156

ROOM

168

STAIRS

04

ROOM

181

ROOM

179

ROOM

177

ROOM

175

ROOM

165

ROOM

163

ROOM

161

ROOM

159

ROOM

157

ROOM

155

ROOM

167

ROOM

169

STAIRS

03

ROOM

121

ROOM

123

ROOM

125

ROOM

127

ROOM

129

ROOM

131

LOUNGE

135

LOUNGE

137

ROOM

133

STAIRS

02

ROOM

128

ROOM

134

ROOM

136

ROOM

134A

ROOM

134B

ROOM

130

ROOM

137

LOUNGE

139

LAUNDRY

141A

KITCHEN

141B

ROOM

143

ROOM

145

ROOM

149

ROOM

151

ROOM

153

ROOM

147

ROOM

142

ROOM

144

ROOM

146

ROOM

138

ROOM

140

STAIRS

01

B

B

B

B

AS INDICATED BY: 00

KEY NOTES

1. EXISTING TILE FLOOR FINISH TO REMAIN.

2. EXISTING TILES HEARTH TO REMAIN.

3. EXISTING LAMINATE WOOD FLOORING TO REMAIN.

4. EXISTING MECHANICAL UNIT TO REMAIN.

5. EXISTING WATER FOUNTAIN TO REMAIN.

E2/RGH A-401

02

02

02

01

01

03

04

04

04

04

05

05

05

04

FIRE EXTINGUISHER (BRACKET or CABINET)

C3/RGH A-401

C1/RGH A-401

D1/RGH A-401

D3/RGH A-401

DO

WN

DO

WN

UP

UP

UP

UP

03

03

03

03

03

03

03

03

03

03

03

E3/RGH A-401

A4/RGH A-401

E4/RGH A-401

02

02

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-101

NORTH

A1

DEMOLITION PLAN - 2ND FLOOR

RHODES HALL

1/8"=1'-0" -

A3

DEMOLITION PLAN - 2ND FLOOR

HAMIEL HALL

1/8"=1'-0" -

A4

DEMOLITION PLAN - 2ND FLOOR

GARRETT HALL

1/8"=1'-0" -

NORTH NORTH

8' 16'0 4' 8' 16'0 4' 8' 16'0 4'

B

A

B

C

B

A

B

C

B A

B A

B C

B C

ROOM

202

ROOM

201

ROOM

203

ROOM

204

ROOM

206

ROOM

205

ROOM

208

ROOM

207

ROOM

209

ROOM

210

ROOM

213

ROOM

214

ROOM

113

ROOM

216

ROOM

215

ROOM

217

ROOM

218

ROOM

220

ROOM

219

ROOM

288

ROOM

286

ROOM

284

ROOM

282

ROOM

280

ROOM

278

ROOM

276

ROOM

270

ROOM

268

ROOM

266

ROOM

264

ROOM

262

ROOM

260

ROOM

272

STAIRS

04

ROOM

285

ROOM

283

ROOM

281

ROOM

279

ROOM

269

ROOM

267

ROOM

265

ROOM

263

ROOM

261

ROOM

259

ROOM

271

ROOM

273

ROOM

274

SHOWER

275

RESTROOM

277

ROOM

221

ROOM

223

ROOM

225

ROOM

227

ROOM

229

ROOM

231

ROOM

235

ROOM

137

ROOM

233

STAIRS

02

ROOM

228

ROOM

236

ROOM

238

ROOM

234

ROOM

232

ROOM

230

ROOM

137

ROOM

239

ROOM

245

ROOM

247

ROOM

249

ROOM

253

ROOM

255

ROOM

257

ROOM

251

ROOM

246

ROOM

248

ROOM

250

ROOM

242

ROOM

244

STAIRS

01

B

B

B

B

B

B

B

B

DEMOLITION NOTES

REMOVE EXISTING CONSTRUCTION AS INDICATED BY:00

1. NOT USED.

2. REMOVE RUBBER / VINYL STAIR TREAD AND RISERS IN ITS

ENTIRETY. PREPARE STEPS TO RECEIVE NEW FINISH.

3. REMOVE EXISTING 1X4 LIGHT FIXTURE THROUGHOUT THE

CORRIDORS, TYPICAL. REFER TO ELECTRICAL FOR ADDITIONAL

INFORMATION AND EXTEND OF WORK.

4. -

5. -

6. -

7. REMOVE NON-COMPLIANT DOOR KNOB

LEGEND

CARPET

PAINT

WOOD TRIM / RAILING IN HALLWAY

1X4 RECESSED LIGHT FIXTURE

GENERAL NOTES

A. DOCUMENTS ARE BASED ON EXISTING FILES PROVIDED BY NMSU

AND ON FIELD OBSERVATIONS. PRIOR TO BEGINNING ANY

DEMOLITION WORK, MAKE A THOROUGH SURVEY OF THE

BUILDING AND NOTIFY THE ARCHITECT IN WRITING OF ALL

OBSERVED DISCREPANCIES BETWEEN THE EXISTING CONDITIONS

AND THOSE SHOWN ON THE DRAWINGS.

B. PROVIDE MEASURES TO PROTECT ALL MATERIAL AND

EQUIPMENT TO REMAIN DURING THE DURATION OF THE PROJECT.

C. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO THOSE

ITEMS NOTED. OTHER ITEMS OF MINOR NATURE MAY EXIST

WHICH ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS ARE

TO BE REMOVED AS NECESSARY TO PROVIDE ACCESS OR ALLOW

ALTERATIONS FOR THE NEW WORK TO PROCEED.

D. WHERE DEMOLITION EXPOSES SUBSTRATES WHICH WILL

RECEIVE NEW FINISH MATERIALS, PROPERLY REMOVE EXISTING

MATERIALS AS REQUIRED FOR NEW FINISHES.

E. PATCH AND REPAIR EXISTING ADJACENT TO MATCH WHERE

REQUIRED DUE TO DEMOLITION PROCEDURES.

F. OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL

IMPROVEMENTS REPLACED DURING CONSTRUCTION.

COORDINATE WITH OWNER PRIOR TO BEGINNING OF PROJECT

FOR ITEMS TO BE SALVAGED FOR OWNER USE.

G. CONTRACTOR SHALL DISPOSE OF MATERIAL IN A PROPER

MANNER AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION

AND IN ACCORDANCE WITH LOCAL AND STATE CODES AND

ORDINANCES.

NIC - NOT IN CONTRACT

AS INDICATED BY:00

KEY NOTES

1. EXISTING TILE FLOOR FINISH TO REMAIN.

2. EXISTING TILES HEARTH TO REMAIN.

3. EXISTING LAMINATE WOOD FLOORING TO REMAIN.

4. EXISTING MECHANICAL UNIT TO REMAIN.

5. EXISTING WATER FOUNTAIN TO REMAIN.

FIRE EXTINGUISHER (BRACKET or CABINET)

RHODES GARRETT HAMIEL GENERAL NOTES

ROOM

211

ROOM

240

SHOWER

254

SHOWER

252

C2/RGH A-401

03

03

E2/RGH A-401

04

C4/RGH A-401

03

03

03

03

03

02

A3/RGH A-401

E1/RGH A-401

A2/RGH A-401

A1/RGH A-401

04

D2/RGH A-401

D4/RGH A-401

DN

DN

03

03

03

03

03

DN

DN

DN

DN

(SIM)

B

02

02

A. ALL WOOD TRIM / RAILING THROUGHOUT THE HALLWAYS AND FOYERS SHALL BE REFURBISHED AS PART OF THIS SCOPE.

B. EXISTING LAY-IN CEILING TILES, GRID AND 1X4 LIGHT FIXTURES IN CORRIDOR SHALL BE REMOVED AND REPLACED WITH NEW LED FIXTURES AS SPECIFIED. REFER TO

ELECTRICAL FOR SCOPE EXTENTS AND NEW FIXTURE LOCATIONS.

ALTERNATE No. 01 - MODIFY EXISTING FIRE SPRINKLER HEADS TO BE CONCEALED WITHIN THE CEILING WITH ESCUTCHEON FINISH.

C. ALL COMMUNITY RESTROOM TILED SURFACES SHALL RECEIVE "MIRACLE METHOD" TREATMENT. SURFACES INCLUDE TILE FLOOR AND 4'-0" HIGH WAINSCOT. ALL OTHER

NON-TILE SURFACES SHALL RECEIVE NEW PAINT FINISH AS SCHEDULED. REFER TO INTERIOR SHEETS.

D. ALL TILED SURFACES IN SUITE RESTROOMS SHALL RECEIVE "MIRACLE METHOD" TREATMENT. SURFACES INCLUDE BUT ARE NOT LIMITED TO THE ENTIRE FLOOR, RESTROOM

BASE AND THE SHOWER 7'-0" HIGH WAINSCOT WALLS. ALL OTHER SURFACES SHALL RECEIVE NEW PAINT FINISH AS SCHEDULED. REFER TO INTERIOR SHEETS.

E. ALL COMMUNITY SHOWER TILED SURFACES SHALL RECEIVE "MIRACLE METHOD" TREATMENT. SURFACES INCLUDE TILE FLOOR, 4'-0" HIGH WAINSCOT, FULL HEIGHT SHOWER

AND CHANGING STALL WALLS. ALL OTHER SURFACES SHALL RECEIVE NEW PAINT FINISH AS SCHEDULED. REFER TO INTERIOR SHEETS.

F. U.N.O. ALL EQUIPMENT AND FIXTURES SHALL REMAIN UNDISTURBED.

G. IN RESTROOMS WHERE THE "MIRACLE METHOD" WILL BE RECEIVED, EXISTING TOILETS WILL BE REMOVED PRIOR WORK AND REPLACED AT COMPLETION OF WORK.

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-102

NORTH

8' 16'0 4'

A1

DEMOLITINO ROOF PLAN

RHODES GARRETT HAMIEL HALL

3/32"=1'-0" -

DEMOLITION NOTES

REMOVE EXISTING CONSTRUCTION AS INDICATED BY:00

1. REMOVE AND DISPOSE OF EXISTING BALLAST, EPDM MEMBRANE AND RIGID

INSULATION DOWN TO THE EXISTING ROOF DECK STRUCTURE.

2. REMOVE EXISTING ROOF DRAIN BODY, STRAINER AND CLAMPING RING.

3. REMOVE RED MODIFIED BITUMINOUS ROOF SYSTEM AND RECOVERY

BOARD DOWN TO WOOD FRAMING SYSTEM.

4. REMOVE EXISTING METAL FLASHING, WOOD FASCIA AND WOOD LOOKOUTS

ALONG ENTIRE PERIMETER OF HIGH ROOF.

5. REMOVE EXISTING PORTION OF PARAPET WALL IN ORDER TO ALLOW A

SMOOTH AND CONTINUOUS ROOF PLANE.

6. EXISTING ROOF HATCH TO BE REMOVED.

RGH GENERAL NOTES

A. THIS ROOF PLAN SHOWS OVERALL INTENT OF ROOF SLOPES, MECHANICAL

UNIT LOCATIONS, DIFFERENT ROOFING TYPES AND OTHER VARIOUS

ROOFING RELATED ITEMS. CONTRACTOR SHALL REFER TO ROOFING

SHEETS FOR SPECIFIC INFORMATION ON ROOFING MEMBRANE AND

DETAILS ASSOCIATED WITH THE DIFFERENT ROOFING TYPES.

B. CONTRACTOR SHALL PROVIDE BARRICADES, FALL PROTECTION AND ANY

OTHER MEANS TO PROTECT WORKERS AND THE PUBLIC DURING PROJECT.

C. NOT ALL ROOF PENETRATIONS ARE SHOWN FOR CLARITY. ALL ROOF

PENETRATIONS SHALL BE FLASHED TO A POSITIVE SLOPE AWAY FROM

PENETRATION. COORDINATE WITH ALL TRADES.

D. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE, FEDERAL CODES,

STATUTES, REGULATIONS AND LAWS GOVERNING THIS WORK.

E. CONTRACTOR SHALL COORDINATE THE RE-CONNECTION OF ALL ROOFTOP

EQUIPMENT, VENTS, CURBS, ETC.

F. PROVIDE CRICKET ON UPHILL SIDE AT ALL ROOF CURBS GREATER THAN

24".

G. SURROUND ALL MECHANICAL UNITS WITH ROOF PADS - SEE SPECS FOR

EXTENT AND QUANTITY.

H. PROVIDE POSITIVE SLOPE ON CRICKETS.

AS INDICATED BY: 00

KEY NOTES

1. EXISTING MECHANICAL UNIT TO REMAIN.

2. EXISTING ROOF HATCH AND SAFETY RAILING SYSTEM TO REMAIN.

3. EXISTING CHIMNEY / STRUCTURE TO REMAIN.

4. SEE DETAIL D1/RGH A-510 FOR NEW ROOF DRAIN.

01

01

01 01 01 01

01

01

01

01

01

01

01

01

02

02

02

02

02

02

03

03

03

03

03

03

03

03

03

02

04

04

04

04

04

04

04

04

04

04

03

03

01

04

04

E1

/R

GH

A

-5

10

E1

/R

GH

A

-5

10

E1

/R

GH

A

-5

10

E1/RGH A-510

E1/RGH A-510

E1/RGH A-510

E1/RGH A-510

E5

/R

GH

A

-5

10

E5

/R

GH

A

-5

10

E5

/R

GH

A

-5

10

E5

/R

GH

A

-5

10

E5/RGH A-510

E5/RGH A-510

E5/RGH A-510

E5/RGH A-510

E1/RGH A-510

E5/RGH A-510

E4/RGH A-510

E4

/R

GH

A

-5

10

E6

/R

GH

A

-5

10

04

04

04

04

04

E6

/R

GH

A

-5

10

02

04

02

04

D2

/R

GH

A

-5

10

05

05

05

D2

/R

GH

A

-5

10

D2/RGH A-510

D3

/R

GH

A

-5

10

D3

/R

GH

A

-5

10

D3/RGH A-510

06

02

04

E4

/R

GH

A

-5

10

SLOPE

2:12

SLOPE

2:12

RID

GE

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-103

GENERAL NOTES

A. DIMENSIONS ARE TO FACE OF STUD, CMU, OR CENTERLINE OF

STRUCTURE UNLESS NOTED OTHERWISE.

B. COORDINATE WITH MEP DRAWINGS FOR LOCATIONS OF FIXTURES.

LOCATE AS SHOWN ON ARCHITECTURAL PLANS AND DETAILS.

NOTIFY ARCHITECT OF CONFLICTS, PRIOR TO CONSTRUCTION.

C. CENTER DEVICES, SPRINKLER HEADS, ETC. IN CEILING TILES UNO.

NORTH

A1

REFLECTED CEILING PLAN - 1ST

FLOOR RHODES HALL

1/8"=1'-0"

A2

REFLECTED CEILING PLAN - 1ST

FLOOR HAMIEL HALL

1/8"=1'-0"

A4

REFLECTED CEILING PLAN - 1ST

FLOOR GARRETT HALL

1/8"=1'-0"

NORTH NORTH

8' 16'0 4' 8' 16'0 4' 8' 16'0 4'

LEGEND

B

B

B

B

B

A

B

C

B

A

B

C

B A

B A

B C

B C

RECESSED LIGHT FIXTURE

2 x 2 ACOUSTICAL LAY-IN CEILING SYSTEM

ROOM

102

ROOM

101

ROOM

103

ROOM

104

ROOM

106

ROOM

105

ROOM

108

LOUNGE

107

SHOWER

150

RESTROOM

148

SHOWER / BATH

126

SHOWER

171

RESTROOM

173

LOUNGE

ROOM

110

ROOM

113

ROOM

114

LOUNGE

111

ROOM

116

ROOM

115

ROOM

117

ROOM

118

ROOM

120

ROOM

119

ROOM

184

ROOM

182

ROOM

180

ROOM

178

ROOM

176

ROOM

174

ROOM

172

ROOM

166

ROOM

164

ROOM

162

ROOM

160

ROOM

158

ROOM

156

ROOM

168

STAIRS

04

ROOM

181

ROOM

179

ROOM

177

ROOM

175

ROOM

165

ROOM

163

ROOM

161

ROOM

159

ROOM

157

ROOM

155

ROOM

167

ROOM

169

STAIRS

03

ROOM

121

ROOM

123

ROOM

125

ROOM

127

ROOM

129

ROOM

131

LOUNGE

135

LOUNGE

137

ROOM

133

STAIRS

02

ROOM

128

ROOM

134

ROOM

136

ROOM

134A

ROOM

134B

ROOM

130

ROOM

137

LOUNGE

139

LAUNDRY

141A

KITCHEN

141B

ROOM

143

ROOM

145

ROOM

149

ROOM

151

ROOM

153

ROOM

147

ROOM

142

ROOM

144

ROOM

146

ROOM

138

ROOM

140

STAIRS

01

B

B

B

B

KEY NOTES

1. ________________________________________________________

UP

UP

UP

SUPPLY AIR GRILLE

RETURN AIR OR

EXHAUST GRILLE

EXIT LIGHTS

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-104

NORTH

A1

REFLECTED CEILING PLAN - 2ND

FLOOR RHODES HALL

1/8"=1'-0" -

A3

REFLECTED CEILING PLAN - 2ND

FLOOR HAMIEL HALL

1/8"=1'-0" -

A4

REFLECTED CEILING PLAN - 2ND

FLOOR GARRETT HALL

1/8"=1'-0" -

NORTH NORTH

8' 16'0 4' 8' 16'0 4' 8' 16'0 4'

B

A

B

C

B

A

B

C

B A

B A

B C

B C

ROOM

202

ROOM

201

ROOM

203

ROOM

204

ROOM

206

ROOM

205

ROOM

208

ROOM

207

ROOM

209

ROOM

210

ROOM

213

ROOM

214

ROOM

113

ROOM

216

ROOM

215

ROOM

217

ROOM

218

ROOM

220

ROOM

219

ROOM

288

ROOM

286

ROOM

284

ROOM

282

ROOM

280

ROOM

278

ROOM

276

ROOM

270

ROOM

268

ROOM

266

ROOM

264

ROOM

262

ROOM

260

ROOM

272

STAIRS

04

ROOM

285

ROOM

283

ROOM

281

ROOM

279

ROOM

269

ROOM

267

ROOM

265

ROOM

263

ROOM

261

ROOM

259

ROOM

271

ROOM

273

ROOM

274

SHOWER

275

RESTROOM

277

ROOM

221

ROOM

223

ROOM

225

ROOM

227

ROOM

229

ROOM

231

ROOM

235

ROOM

137

ROOM

233

STAIRS

02

ROOM

228

ROOM

236

ROOM

238

ROOM

234

ROOM

232

ROOM

230

ROOM

137

ROOM

239

ROOM

245

ROOM

247

ROOM

249

ROOM

253

ROOM

255

ROOM

257

ROOM

251

ROOM

246

ROOM

248

ROOM

250

ROOM

242

ROOM

244

STAIRS

01

B

B

B

B

B

B

B

B

ROOM

211

ROOM

240

SHOWER

254

SHOWER

252

GENERAL NOTES

A. DIMENSIONS ARE TO FACE OF STUD, CMU, OR CENTERLINE OF

STRUCTURE UNLESS NOTED OTHERWISE.

B. COORDINATE WITH MEP DRAWINGS FOR LOCATIONS OF FIXTURES.

LOCATE AS SHOWN ON ARCHITECTURAL PLANS AND DETAILS.

NOTIFY ARCHITECT OF CONFLICTS, PRIOR TO CONSTRUCTION.

C. CENTER DEVICES, SPRINKLER HEADS, ETC. IN CEILING TILES UNO.

LEGEND

RECESSED LIGHT FIXTURE

2 x 2 ACOUSTICAL LAY-IN CEILING SYSTEM

KEY NOTES

1. ________________________________________________________

SUPPLY AIR GRILLE

RETURN AIR OR

EXHAUST GRILLE

EXIT LIGHTS

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-105

LEGEND

CARPET TILE (CPT)

AS INDICATED BY: 00

KEY NOTES

1. CHANGING STALL SEAT, PAINTED. TYPICAL EACH COMMUNITY SHOWER CHANGING

STALL

2. WOOD TRIM RAILING, REFERENCE GENERAL NOTE 'B'.

3. EXISTING PORCELAIN TILE FLOOR AND WALL TO REMAIN, PREPARE ALL FLOOR AND

WALL TILED SURFACES TO RECEIVE MIRACLE METHOD TREATMENT AS

SCHEDULED.

4. EXISTING FLOOR FINISH TO REMAIN, NO WORK. PROTECT PRIOR TO PAINTING.

5. HANDRAILS TO BE PAINTED, COLOR AS SCHEDULED.

6. REPLACE MISSING STAIR TREADS WHERE APPLICABLE, MATCH TO EXISTING.

7. TILE TREAD AND TILE RISER AS SPECIFIED, REFER TO INTERIOR FINISH LEGEND.

A1

ENLARGED PLAN

TYPICAL SUITE W/ SHARED RESTROOM

1/4"=1'-0" -

C1

STAIRS @ 1st FLOOR

1/4"=1'-0" -

D1

STAIRS @ 1st FLOOR

1/4"=1'-0" -

4' 8'0 2'

4' 8'0 2'

4' 8'0 2'

D2

STAIRS @ 2nd FLOOR

1/4"=1'-0"

C2

STAIRS @ 2nd FLOOR

1/4"=1'-0"

A3

TYPICAL SHOWER AND RESTROOM

1/4"=1'-0"

NO WORK THIS ROOM

DEMOLITION NOTES

REMOVE EXISTING CONSTRUCTION AS INDICATED BY:00

1. REMOVE EXISTING WOOD DOOR AND FRAME. PREPARE OPENING TO RECEIVE

NEW HOLLOW METAL DOOR FRAME AND WOOD DOOR. PAINT FRAME, COLOR AS

SCHEDULED.

2. -

3. TILED SURFACES IN SUITE RESTROOM SHALL RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE BUT ARE NOT LIMITED TO THE ENTIRE FLOOR,

RESTROOM BASE AND THE THE SHOWER 7'-0" HIGH WAINSCOT WALLS.

RHODES GARRETT HAMIEL GENERAL NOTES

WOOD TRIM / RAILING IN HALLWAY

C4

TYPICAL SUITE RESTROOM PLAN

1/4"=1'-0"

A4

TYPICAL LOUNGE AT FIRST FLOOR

NTS

A5

TYPICAL LOUNGE AT SECOND FLOOR

NTS

C3

ENLARGED PLAN @ STAIRS

1/4"=1'-0"

D3

STAIRS @ 1st FLOOR

1/4"=1'-0"

E3

KITCHEN/ LAUNDRY

1/4"=1'-0"

A. UNLESS NOTED OTHERWISE, ALL DOORS SHOWN ARE TO BE REMOVED AND

REPLACED, INCLUDING HARDWARE. FOR CLARITY, ALL OTHER DOORS ARE NOT

SHOWN.

B. ALL WOOD TRIM / RAILING INDICATED THROUGHOUT THE HALLWAYS AND FOYERS

SHALL BE REFURBISHED AS SPECIFIED

C. FOR EACH SPACE, SUITE, AND HALLWAY IDENTIFIED WITH "CARPET" HATCH, CARPET

AND BASE SHALL BE REMOVED, U.N.O. PREPARE FLOOR SLAB TO RECEIVE NEW

CARPET FINISH. PREPARE WALL, PATCH AND REPAIR AS NECESSARY TO RECEIVE

NEW BASE.

D. FOR EACH SPACE, SUITE, AND HALLWAY IDENTIFIED WITH "PAINT" HATCH, ALL DOOR

FRAMES, WALLS AND HARD CEILINGS SHALL BE PAINTED, U.N.O. PREPARE ALL

SURFACES TO RECEIVE NEW PAINT. ALL SUITE CLOSETS ARE TO BE PAINTED

INCLUDING CLOSET WOOD SHELF. ALL SUITE RESTROOM SURFACES NOT TILED

SHALL BE PAINTED.

E. EXISTING 1X4 LIGHT FIXTURES SHOWN ARE TO BE REMOVED AND REPLACED WITH

NEW 2X4 FIXTURE. REFER TO ELECTRICAL FOR NEW WORK SCOPE AND LOCATION.

ALTERNATE No. 01 - REMOVE AND REPLACE EXISTING SUSPENDED GRID AND

ACOUSTICAL CEILING PANELS.

ALTERNATE No. 02 - MODIFY EXISTING FIRE SPRINKLER HEADS TO BE CONCEALED

WITHIN THE CEILING WITH ESCUTCHEON FINISH.

F. COMMUNITY RESTROOM TILED SURFACES TO RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE TILE FLOOR AND 4'-0" HIGH WAINSCOT. ALL OTHER

SURFACES SHALL RECEIVE NEW PAINT FINISH.

G. TILED SURFACES IN SUITE RESTROOM SHALL RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE BUT ARE NOT LIMITED TO THE ENTIRE FLOOR,

RESTROOM BASE AND THE THE SHOWER 7'-0" HIGH WAINSCOT WALLS. ALL OTHER

SURFACES SHALL RECEIVE NEW PAINT FINISH.

H. COMMUNITY SHOWER TILED SURFACES TO RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE TILE FLOOR, 4'-0" HIGH WAINSCOT, FULL HEIGHT

SHOWER AND CHANGING STALL WALLS. ALL OTHER SURFACES SHALL RECEIVE NEW

PAINT FINISH.

4' 8'0 2'

D4

STAIRS @ 2nd FLOOR

1/4"=1'-0"

LUXURY VINYL TILE (LVT)

GENERAL FINISH NOTES

A2

ENLARGED PLAN

AT RESTROOMS

1/4"=1'-0" -

4' 8'0 2'

E1

ENLARGED PLAN

SHOWER/ BATH

1/4"=1'-0" -

4' 8'0 2' 4' 8'0 2'

4' 8'0 2' 4' 8'0 2' 4' 8'0 2'

4' 8'0 2' 4' 8'0 2' 4' 8'0 2'

4' 8'0 2' 4' 8'0 2' 4' 8'0 2'

03

03

03

03

03

03

03

PT

2

04

04

PT

3P

T3

PT

3P

T3

04

05

E4

TYPICAL HALLWAY BATHROOM

1/4"=1'-0"

4' 8'0 2'

05

05 05

05

05

05

05

03

05

05

05

05

0606

06

06

06

06

06

06

04

07

07

07

07

** ALL EXISTING FINISHES SHALL REMAIN UNO. DENOTED ON ARCHITECTURAL PLANS.

REFER TO I-001 FOR FINISH LEGEND AND SCHEDULE.

FLOORS:

A. ALL FLOORS SHALL RECEIVE (CPT1) UNO.

B. ALL TILED FLOOR SURFACES IN RESTROOMS AND SHOWER ROOMS SHALL

RECEIVE (MM2).

C. REFER TO ENLARGED FINISH PLANS FOR DENOTATIONS AND PATTERN

DIRECTIONS.

BASE:

A. ALL BASE SHALL BE (RB1).

WALLS:

A. ALL WALLS SHALL RECEIVE (PT1) UNO.

B. ALL TILED WALL SURFACES IN RESTROOMS AND SHOWER ROOMS SHALL RECEIVE

(MM1).

C. REFER TO ENLARGED FINISH PLANS FOR FINISH TAGS AND TERMINATION POINTS.

CEILINGS:

A. PAINT ALL VERTICAL AND HORIZONTAL SURFACES OF DRYWALL AND PLASTER

CEILINGS (PT1) UNO.

MILLWORK:

A. ALL EXISTING MILLWORK SHALL RECEIVE NO NEW FINISH.

MISCELLANEOUS:

A. ALL NEW AND EXISTING WOOD DOORS SHALL RECEIVE (TPF1).

B. ALL EXISTING INTERIOR PAINTED DOORS SHALL RECEIVE (PT1).

C. ALL PAINTED DOOR TRIM SHALL BE (PT4).

D. ALL STAIR HANDRAILS SHALL BE (PT4) UNO.

E. ALL STAIR TREADS SHALL RECEIVE (CT1) UNO.

F. ALL STAIR RISERS SHALL RECEIVE (CT2) UNO.

G. ALL WOOD TRIM / RAILING THROUGHOUT THE HALLWAYS AND FOYERS SHALL

RECEIVE (TPF1).

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-401

E1

PARAPET DETAIL

1 1/2"=1'-0"

EXISTING STUCCO OVER

EXISTING WALL

CONT SEALANT

CONT COUNTERFLASHING

TERMINATION BAR

THERMOPLASTIC MEMBRANE

(HEAT WELD)

BASE FLASHING

(HEAT WELD)

THERMOPLASTIC

MEMBRANE

1/2" FIBER BOARD

6" POLYISOCYANURATE

INSULATION

EXISTING WOOD

DECK TO REMAIN

EXISTING STRUCTURE

TO REMAIN

E2

VENT FLASH DETAIL

1 1/2"=1'-0"

ROLL DOWN FLASHING

1" MIN DOWN INTO PIPE

PLUMBING VENT

STACK

SEALANT

MODIFIED MEMBRANE

FLASHING

MODIFIED BASE FLASHING

FELT BASE PLIES

THERMOPLASTIC

MEMBRANE

1/2" FIBER BOARD

4" MIN

12

" M

IN

.

E3

LARGE PIPE VENTILATION DET.

1 1/2"=1'-0"

VENT OR PIPE

SEALANT

DRAWBAND

WATERTIGHT

SHEET METAL

RAIN COLLAR

NON-SHRINK

GROUT

SHEET METAL,

WATERTIGHT

PITCH PAN

MODIFIED

MEMBRANE

FLASHING

BASE FLASHING

FELT BASE PLIES

4" MIN.

E4

CORNICE DETAIL

1 1/2"=1'-0"

METAL EDGE

CONT CLEAT

EXIST (2) 2x8 WITH

(1) 2x6 BETWEEN

EXIST CONT 4x4

EXISTING STUCCO

CONT SEALANT

THERMOPLASTIC HEAT

WELDED MEMBRANE BASE FLASHING

THERMOPLASTIC

MEMBRANE

MODIFIED

BASE PLY

E5

ROOF DETAIL

1 1/2"=1'-0"

EXISTING STUCCO

6" POLYISOCYANURATE

INSULATION

EXISTING WOOD

DECK TO REMAIN

BASE PLY

MEMBRANE

THERMOPLASTIC

FLASHING

MEMBRANE

CONT METAL FLASHING

E6

EXPANSION JOINT

1 1/2"=1'-0"

EXPANSION JOINT

PREMANUFACTURED

COVER

EXISTING WOOD

DECK TO REMAIN

EXISTING WOOD

DECK TO REMAIN

SECURED METAL CAP (WITH FASTENERS

and NEOPRENE WASHERS

CHAMFER EACH

SIDE OF WOOD

CURB TO DRAIN

FLEXIBLE WATER

PROOF MEMBRANE

CLOSURE

COMPRESSIBLE

INSULATION

THERMOPLASTIC MEMBRANE (HEAT WELD)

BASE FLASHING

BASE PLY

THERMOPLASTIC

MEMBRANE

D1

ROOF DRAIN

3"=1'-0"

STRAINER

LEAD FLASHING (30"

SQ MIN SET IN MASTIC)

THERMOPLASTIC

MEMBRANE (HEAT

WELD) 3" MIN

CLAMPING RING

BASE FLASHING

BASE PLY

D2

DETAIL @ ROOF

1 1/2"=1'-0"

THERMOPLASTIC

MEMBRANE

1/2" FIBER BOARD

6" POLYISOCYANURATE

INSULATION

CONT METAL

CAP

EXISTING WOOD

DECK TO REMAIN

CANT STRIP

CONT 2x WOOD

NAILER (BOTH

SIDES)

RUN ROOFING UP

AND OVER PARAPET

CONT SEALANT

CONT COUNTERFLASHING

TERMINATION BAR

THERMOPLASTIC MEMBRANE

(HEAT WELD)

BASE FLASHING

(HEAT WELD)

D3

DETAIL @ ROOF

1 1/2"=1'-0"

CONT CLEAT

CONT SEALANT

1/2" FIBER BOARD

BASE FLASHING

A1

HALLWAY RAIL DETAIL

3"=1'-0"

3/8"

1 1/8"

4 1

/2

"2

"

3/8"

7/8"

1/4"

NEW RAILING

PAINT TO MATCH

WALL COLOR

EXIST WOOD

RAILING (1x6)

PAINT TO MATCH

WALL COLOR

D4

ROOF HATCH

1 1/2"=1'-0"

ROOF HATCH

EXTERIOR LOCK

PROVISION

IN

TE

RIO

R

HA

ND

LE

FASTENER WITH NEOPRENE WASHER

INTEGRAL CAP FLASHING

TERMINATION BAR FASTENED 8" O.C.

60 MIL THERMOPLASTIC FB MEMBRANE

3" MIN ON FIELD, HEAT WELD

BASE FLASHING

CANT FASTENED TO NAILER

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH A-510

A

ATC ACOUSTICAL TILE CEILING

AWT ACOUSTICAL WALL TREATMENT

B

BG BUMPER GUARD

BNT BULL NOSE TILE

C

CG CORNER GUARD

CHR CHAIR RAIL

CPT CARPET

CT CERAMIC TILE

CUB CUBICAL CURTAIN

CURT CURTAIN (PRIVACY, STAGE)

D

DLS DIMENSIONAL LETTERS

DRS DOUBLE ROLLER SHADE

F

FLS FLUID APPLIED SPORTS FLOORING

FWP FABRIC WRAPPED PANELS

G

GLS ARCHITECTURAL TILE

GLT GLASS TILE

GT GROUT

H

HIC HIGH IMPACT WALL COVERING

HLB HORIZONTAL LOUVER BLINDS

HR HANDRAIL

K

KPL KICKPLATE

L

LINO LINOLEUM

LKR LOCKER

LVT LUXURY VINYL TILE

M

MM MIRACLE METHOD

MT METAL THRESHOLD

MTL METAL

MTLB METAL BASE

P

PB PAINTED BASE

PC POLISHED CONCRETE

PLAM PLASTIC LAMINATE

PMTL PAINTED METAL

PT PAINT

Q

QT QUARRY TILE

QTZ QUARTZ SLAB

R

RACC RESILIENT ACCESSORY

RB RESILIENT BASE (VINYL, RUBBER, TP)

RBR RUBBER (TILE AND SHEET)

RES RESIN PANEL

RFS RESILIENT SPORTS FLOORING

RSN PLASTIC RESIN PANEL

S

SCN SEALED CONCRETE

SCB SELF COVE BASE

SGN SIGNAGE

SNC STAINED CONCRETE

SRP SLIP RESISTANT PROTECTIVE FLOORING

SRS SINGLE ROLLER SHADE

SSM SOLID SURFACE MATERIAL

SST STAINLESS STEEL

SWS SPECIAL WALL SURFACES

SV SHEET VINYL

T

TC TOILET COMPARTMENTS

TER TERRAZZO

TKBD TACKBOARD

TPF TRANSPARENT FINISH

TS TRANSITION STRIP

V

VCT VINYL COMPOSITION TILE

VWC VINYL WALL COVERING

ABBREVIATIONS FINISH LEGEND

DESIGNATION DESCRIPTION MANUFACTURE STYLE COLOR REMARKS

SECTION 09 91 23 - INTERIOR PAINTING

PT1 FIELD PAINT SHERWIN WILLIAMS SW 6064 RETICENCE

PT2 ACCENT PAINT SHERWIN WILLIAMS XXXX

PT3 ACCENT PAINT SHERWIN WILLIAMS XXXX

PT4 ACCENT PAINT SHERWIN WILLIAMS 1011-7 ONYX

SECTION 09 96 00 - HIGH-PERFORMANCE COATINGS

MM1 SPECIAL WALL COATING MIRACLE METHOD NATURAL ACCENTS ONYX 44136 RESTROOM WALL COATING

MM2 SPECIAL WALL COATING MIRACLE METHOD NATURAL ACCENTS GRAPHITE 57500 RESTROOM FLOOR COATING

END OF LEGEND

A. CONTRACTOR SHALL VERIFY, CLARIFY, AND COORDINATE DIMENSIONAL

DISCREPANCIES (NEW AND EXISTING) FROM THIS OR ANY PLAN, SECTION OR

ELEVATION WITH THE INTERIOR DESIGNER PRIOR TO CONSTRUCTION.

B. VERIFY WITH THE OWNER THE FINAL DISPOSITION OF ANY MILLWORK, SHELVING,

DOORS, AND EQUIPMENT REMOVED DURING CONSTRUCTION.

C. MATERIALS TO REMAIN SHALL BE PROTECTED FROM DAMAGE DURING

CONSTRUCTION. PATCH AND REPAIR ALL ADJACENT WALLS, CEILINGS, FLOORS,

AND BASE TO MATCH EXISTING WHERE DEMOLITION OR DAMAGE OCCURS. NEW

FINISHES SHALL MATCH THE ADJACENT WALL, CEILING, FLOOR, AND BASE, IN

TEXTURE, PATTERN, AND COLOR. INTERIOR DESIGNER SHALL APPROVE FINAL

WORK.

D. PREPARE SUBSTRATES TO RECEIVE NEW FINISHES WHERE SPECIFIED PER

MANUFACTURE'S WRITTEN GUIDELINES. REFERENCE I-001 FOR FINISH LEGEND

AND FINISH SCHEDULE. NOT ALL FINISHES ARE DEPICTED ON THIS DRAWING.

E. WHERE DAMAGE OCCURS FROM INSTALLATION OF CEILING OR FIRE ALARM,

PATCH AND REPAIR TO MATCH EXISTING.

F. CONTRACTOR SHALL REFERENCE ALL DRAWINGS FOR ADDITIONAL FINISH

LOCATIONS TO INCLUDE WALL FINISH PLANS, FLOOR FINISH PLANS, REFLECTED

CEILING PLANS, RELATED DETAILS AND APPENDIX IN THE PROJECT MANUAL.

SPECIFIC LOCATIONS WHERE THE VARIOUS MATERIALS ARE REQUIRED ARE

INDICATED IN DRAWING. WHEN COLOR IS NOT DESIGNATED FOR ITEMS, THE

CONTRACTOR SHALL ASK FOR A COLOR SELECTION.

G. A TRANSITION SHALL BE PROVIDED BETWEEN DISSIMILAR FLOORING TYPES. THE

TRANSITION SHALL BE THE APPROPRIATE THICKNESS TO ACCOMMODATE THE

SCHEDULED FLOORING AND CREATE AN ACCESSIBLE TRANSITION BETWEEN

FLOORING TYPES.

GENERAL NOTES

GENERAL FINISH NOTES

** ALL EXISTING FINISHES SHALL REMAIN UNO. DENOTED ON ARCHITECTURAL PLANS.

REFER TO I-001 FOR FINISH LEGEND AND SCHEDULE.

FLOORS:

A. ALL FLOORS SHALL RECEIVE (CPT1) UNO.

B. ALL TILED FLOOR SURFACES IN RESTROOMS AND SHOWER ROOMS SHALL

RECEIVE (MM2).

WALLS:

A. ALL WALLS SHALL RECEIVE (PT1) UNO.

B. ALL TILED WALL SURFACES IN RESTROOMS AND SHOWER ROOMS SHALL RECEIVE

(MM1).

C. REFER TO ENLARGED FINISH PLANS FOR FINISH TAGS AND TERMINATION POINTS.

CEILINGS:

A. PAINT ALL VERTICAL AND HORIZONTAL SURFACES OF DRYWALL AND PLASTER

CEILINGS (PT1) UNO.

MISCELLANEOUS:

A. ALL STAIR HANDRAILS SHALL BE (PT4) UNO.

B. ALL STAIR TREADS SHALL RECEIVE (CT1) UNO.

C. ALL STAIR RISERS SHALL RECEIVE (CT2) UNO.

D. ALL WOOD TRIM / RAILING THROUGHOUT THE HALLWAYS AND FOYERS SHALL

RECEIVE (TPF1).

I-001

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

LEGEND

AS INDICATED BY: 00

KEY NOTES

A1

WALL FINISH PLAN

TYP. GARRETT HALL RESTROOM

1/4"=1'-0" -

C1

WALL FINISH PLAN

TYP. GARRETT HALL RESTROOM

1/4"=1'-0" -

D1

FLOOR FINISH PLAN

TYP. HAMIEL HALL RESTROOM

1/4"=1'-0" -

4' 8'0 2'

4' 8'0 2'

4' 8'0 2'

NO WORK THIS ROOM

RHODES GARRETT HAMIEL GENERAL NOTES

WOOD TRIM / RAILING IN HALLWAY

A. UNLESS NOTED OTHERWISE, ALL DOORS SHOWN ARE TO BE REMOVED AND

REPLACED, INCLUDING HARDWARE. FOR CLARITY, ALL OTHER DOORS ARE NOT

SHOWN.

B. ALL WOOD TRIM / RAILING INDICATED THROUGHOUT THE HALLWAYS AND FOYERS

SHALL BE REFURBISHED AS SPECIFIED

C. FOR EACH SPACE, SUITE, AND HALLWAY IDENTIFIED WITH "CARPET" HATCH, CARPET

AND BASE SHALL BE REMOVED, U.N.O. PREPARE FLOOR SLAB TO RECEIVE NEW

CARPET FINISH. PREPARE WALL, PATCH AND REPAIR AS NECESSARY TO RECEIVE

NEW BASE.

D. FOR EACH SPACE, SUITE, AND HALLWAY IDENTIFIED WITH "PAINT" HATCH, ALL DOOR

FRAMES, WALLS AND HARD CEILINGS SHALL BE PAINTED, U.N.O. PREPARE ALL

SURFACES TO RECEIVE NEW PAINT. ALL SUITE CLOSETS ARE TO BE PAINTED

INCLUDING CLOSET WOOD SHELF. ALL SUITE RESTROOM SURFACES NOT TILED

SHALL BE PAINTED.

E. EXISTING 1X4 LIGHT FIXTURES SHOWN ARE TO BE REMOVED AND REPLACED WITH

NEW 2X4 FIXTURE. REFER TO ELECTRICAL FOR NEW WORK SCOPE AND LOCATION.

ALTERNATE No. 01 - REMOVE AND REPLACE EXISTING SUSPENDED GRID AND

ACOUSTICAL CEILING PANELS.

ALTERNATE No. 02 - MODIFY EXISTING FIRE SPRINKLER HEADS TO BE CONCEALED

WITHIN THE CEILING WITH ESCUTCHEON FINISH.

F. COMMUNITY RESTROOM TILED SURFACES TO RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE TILE FLOOR AND 4'-0" HIGH WAINSCOT. ALL OTHER

SURFACES SHALL RECEIVE NEW PAINT FINISH.

G. TILED SURFACES IN SUITE RESTROOM SHALL RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE BUT ARE NOT LIMITED TO THE ENTIRE FLOOR,

RESTROOM BASE AND THE THE SHOWER 7'-0" HIGH WAINSCOT WALLS. ALL OTHER

SURFACES SHALL RECEIVE NEW PAINT FINISH.

H. COMMUNITY SHOWER TILED SURFACES TO RECEIVE "MIRACLE METHOD"

TREATMENT. SURFACES INCLUDE TILE FLOOR, 4'-0" HIGH WAINSCOT, FULL HEIGHT

SHOWER AND CHANGING STALL WALLS. ALL OTHER SURFACES SHALL RECEIVE NEW

PAINT FINISH.

SHOWER

150

RESTROOM

148

SHOWER / BATH

126

SHOWER

171

RESTROOM

173

A. CONTRACTOR SHALL VERIFY, CLARIFY, AND COORDINATE DIMENSIONAL

DISCREPANCIES (NEW AND EXISTING) FROM THIS OR ANY PLAN, SECTION OR

ELEVATION WITH THE INTERIOR DESIGNER PRIOR TO CONSTRUCTION.

B. VERIFY WITH THE OWNER THE FINAL DISPOSITION OF ANY MILLWORK, SHELVING,

DOORS, AND EQUIPMENT REMOVED DURING CONSTRUCTION.

C. MATERIALS TO REMAIN SHALL BE PROTECTED FROM DAMAGE DURING

CONSTRUCTION. PATCH AND REPAIR ALL ADJACENT WALLS, CEILINGS, FLOORS,

AND BASE TO MATCH EXISTING WHERE DEMOLITION OR DAMAGE OCCURS. NEW

FINISHES SHALL MATCH THE ADJACENT WALL, CEILING, FLOOR, AND BASE, IN

TEXTURE, PATTERN, AND COLOR. INTERIOR DESIGNER SHALL APPROVE FINAL

WORK.

D. PREPARE SUBSTRATES TO RECEIVE NEW FINISHES WHERE SPECIFIED PER

MANUFACTURE'S WRITTEN GUIDELINES. REFERENCE I-001 FOR FINISH LEGEND

AND FINISH SCHEDULE. NOT ALL FINISHES ARE DEPICTED ON THIS DRAWING.

E. WHERE DAMAGE OCCURS FROM INSTALLATION OF CEILING OR FIRE ALARM,

PATCH AND REPAIR TO MATCH EXISTING.

F. CONTRACTOR SHALL REFERENCE ALL DRAWINGS FOR ADDITIONAL FINISH

LOCATIONS TO INCLUDE WALL FINISH PLANS, FLOOR FINISH PLANS, REFLECTED

CEILING PLANS, RELATED DETAILS AND APPENDIX IN THE PROJECT MANUAL.

4' 8'0 2'

C1

WALL FINISH PLAN

TYP. GARRETT HALL RESTROOM

1/4"=1'-0" -

A1

FLOOR FINISH PLAN

TYP. GARRETT HALL RESTROOM

1/4"=1'-0" -

4' 8'0 2'

RESTROOM

148

C1

FLOOR FINISH PLAN

TYP. GARRETT HALL RESTROOM

1/4"=1'-0" -

4' 8'0 2'

SHOWER / BATH

126

MM1

4' 8'0 2'

C1

FLOOR FINISH PLAN

TYP. GARRETT HALL RESTROOM

1/4"=1'-0" -

MM2

GENERAL NOTES

GENERAL FINISH NOTES

4' 8'0 2'

RESTROOM

173

** ALL EXISTING FINISHES SHALL REMAIN UNO. DENOTED ON ARCHITECTURAL PLANS.

REFER TO I-001 FOR FINISH LEGEND AND SCHEDULE.

FLOORS:

A. REFER TO FLOOR FINISH PLANS.

WALLS:

A. ALL GYPSUM BOARD WALL SHALL BE PAINTED (PT1) UNO.

CEILINGS:

A. ALL ACOUSTICAL CEILINGS SHALL BE (ATC1) UNO.

B. ALL CEILINGS SHALL BE PAINTED (PT1) UNO.

MM2

MM1

MM1

SHOWER

150

MM1

MM1

MM1

MM2

MM2

MM2

D1

FLOOR FINISH PLAN

TYP. HAMIEL HALL RESTROOM

1/4"=1'-0" -

SHOWER

171

MM2

ISSUING OFFICE:

NO DESCRIPTIONDATE

PROJECT NO:

KEY PLAN

654321

654321

A

B

C

D

E

LAS CRUCES 8918.17

1

THIS DOCUMENT IS RELEASED ON JUNE 22, 2018

FOR THE PURPOSE OF INTERIM REVIEW UNDER

THE AUTHORITY OF MICHAEL THOMAS STILLS,

R.A., NEW MEXICO LICENSE #5580. IT IS NOT TO

BE USED FOR REGULATORY APPROVAL,

CONSTRUCTION, BIDDING OR PERMIT

PURPOSES. PARKHILL, SMITH & COOPER, INC.

RGH I-401