Friendly Inspection ServicesProperty Inspection Report
Cover Page
Sample reportInspection prepared for: Sample Report
Date of Inspection: 4/7/2015 Time: 8:45 Start, 11:00 finish Age of Home: 1994
Weather: Cloudy, 43 degreesSample report
1994 Home
Inspector: Harvey SansoucyMA License #28 NH License #258 VT License #143.0113065Friendly Inspection Services, 67 Mt. Gardner Rd., Bath, NH 03740
Email: [email protected]
Friendly Inspection Services Sample report
Page 1 of 20
Roof
Please understand that we cannot see through walls or enter crawl spaces that are less than 3 feet, nor can we enterattics that are not designed for safe passage. This inspection is not an assessment of building or electrical codes. This report does not guarantee the absence of wood boring insects. It is a visual, non destructive investigation forevidence of past or present wood boring insect activity. We are not responsible for insect damage that was concealed ornot accessible at the time of the inspection. If wood boring activity is discovered during the interior or exterior inspection itwill be noted on the report. No evaluation will be made regarding air, soil, lead, water, asbestos, formaldehyde, lead paint, molds, radon, pipingoutside the foundation or gas fittings or regulators. This report is not an engineering or building code study, and becauseof that we are not responsible for repairs to bring the building in compliance with current building codes. Only those components specifically mentioned in this report have been inspected and any other components notinspected are not part of this report and as such we make no statement regarding the condition of these un inspectedareas. You should evaluate and act on any comments before continuing with your purchase. This report is exclusive to you and is not transferable. LegendS = Satisfactory, component condition is functional and is consistent with its original purpose but may show signs ofnormal wear or deterioration.A= Acceptable, recommend upgrade, maintenance or may require repair or replacement within a short time.C= Concern, component is an area of concern or requires repair now.H= Hidden, component is not viewable using reasonable effort.NA = Does not apply to this inspection Basis of inspection This report is based on observations of the condition of the inspected building and components at the listed date andtime of the inspection. FRIENDLY INSPECTION does not give any warranty or guaranty. This report is made using thebest of our ability and judgement. Recommended action The summary at the end consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expenses to correct or items I would like to draw extraattention to. The summary is not a complete listing of all the findings in the report, and reflects theopinion of the inspector. Please review all of the pages of the report as the summary alone does notexplain all the issues. All repairs should be done by a licensed or bonded trade or profession. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.
Roof ConditionS A C N/A H
XType of roof: GableMaterials: Asphalt shinglesBinocular inspection from ground • Roofing nearing the end of it’s useful life • Consult aroofing contractor
ChimneyS A C N/A H
XChimney type: MetalBinocular inspection from ground only
Friendly Inspection Services Sample report
Page 2 of 20
Exterior Areas
Roof penetrationsS A C N/A H
XRoof penetrations appeared to be in good condition
FlashingS A C N/A H
X
GuttersS A C N/A H
XGutter type: Aluminum
Entryway doors & WindowsS A C N/A H
X
Eaves & FaciaS A C N/A H
X
SoffitsS A C N/A H
X
Siding ConditionS A C N/A H
XSiding type: VinylLoose siding observed
Loose siding observed
Friendly Inspection Services Sample report
Page 3 of 20
Grounds
Corner boards and trimS A C N/A H
X
Exterior PaintS A C N/A H
X
Bulkhead / walkoutS A C N/A H
XBulkhead • Missing torsion springs
Missing torsion springsExterior faucet
S A C N/A H
XHoses should be disconnected in winter to prevent freezing
Exterior electricalS A C N/A H
X
Exterior lightingS A C N/A H
XObserved in place
Grading & vegetationS A C N/A H
XAppears to be very flat or slightly depressed, recommend increasing pitch away fromfoundation
Friendly Inspection Services Sample report
Page 4 of 20
Garage
Driveway / walkwayS A C N/A H
XWalkway: PaversDriveway: Asphalt
Porches & DecksS A C N/A H
XLocation and type: Front of building has a wood porch • Rear of building has a wood deckDeteriorated material at back deck • Back deck not child safe, should have proper railings •No joist supports at outer beam, recommend that proper joist supports be installed •Recommend that porch deck frame be bolted to house
Stairs and railingsS A C N/A H
XLocation & type: Front of building has wooden steps • Rear of building has wood stepsRear steps not child safe, recommend proper railings
Garage typeType of garage: Attached
Siding & trim conditionS A C N/A H
XSiding type: Vinyl
Foundation & floorS A C N/A H
XFoundation wall type: ConcreteFloor type: ConcreteCracks observed • Cracks should be monitored for further movement
Cracks observedSills
S A C N/A H
XWood sills
Friendly Inspection Services Sample report
Page 5 of 20
Foundation / basement
Walls, ceilings / firewallsS A C N/A H
XType: Wood frame wallsWall surface type: Drywall
ElectricalS A C N/A H
X
Garage doors & openerS A C N/A H
XType of door: Automatic door opener present • overhead doorElectric eye safety system improperly installed • Electric eye units too high
Electric eye units too highFire Door
S A C N/A H
X
Rafters & CeilingS A C N/A H
XTruss roof
Roof ConditionS A C N/A H
XType of roof: GableType of material: Asphalt shinglesRoofing is nearing the end of it’s useful life • Consult a roofing contractor
FoundationS A C N/A H
XType of foundation: ConcreteCracks observed • Recommend sealing with polyurethane caulking to prevent waterpenetration
Friendly Inspection Services Sample report
Page 6 of 20
Cracks observedBasement floor
S A C N/A H
XFloor type: ConcreteCracks observed
Basement windowsS A C N/A H
X
ColumnsS A C N/A H
XType: Concrete filled steel
GirdersS A C N/A H
XType: Wood
SillsS A C N/A H
XType of sills: Pressure treated wood
Floor joistsS A C N/A H
XType of joists: Wood
SubfloorS A C N/A H
XType of subfloor: Plywood
Interior chimneyS A C N/A H
XChimney type: Metal
Friendly Inspection Services Sample report
Page 7 of 20
Electrical
Bulkhead / walk out doorS A C N/A H
XRecommend installing a modern door at hatchway for energy conservation and security
Water penetration and dampnessS A C N/A H
XMoisture: Efflorescence: no • Water stains: yesBasement was dry at time of inspection • Evidence of prior water penetration
Sump pump & dehumidifierS A C N/A H
XNone present
Environmental hazardsS A C N/A H
XEnvironmental issues: None observed at time of inspection
ElectricalS A C N/A H
X
Cable FeedsS A C N/A H
XService: Type: Aluminum, overhead service, drip loop, weatherhead, service entry cable,meter, inspected, Cable entry into meter socket needs to be sealed properly , consult alicensed electrician
Cable entry into meter socket needs to be sealed properlyService panel
S A C N/A H
XAmperage: 200 amp • 120 / 240 voltLocation: BasementEvidence of water in panel • Consult a licensed electrician
Friendly Inspection Services Sample report
Page 8 of 20
Plumbing
Water Heater
Evidence of water in panelBreakers / fuses
S A C N/A H
XType: Circuit breakersAmperage: 15 Amp • 20 Amp • 30 Amp • 40 AmpBreakers are listed for aluminum cable • Corrosion inhibitor observed
Number of breakersS A C N/A H
XPanel appears to be at or below it's rated capacity • 17 breakers
Branch circuitsS A C N/A H
XConductor materials: Copper • Multi strand aluminumWiring type: Non metallic sheathed cable
System groundS A C N/A H
XWater service attachment • Bonded to building water piping
Water pipingS A C N/A H
XWater supply: Town water • Copper water serviceType of pipe: CopperShut off located at water meter
Condition of waste lines and supportsS A C N/A H
XType of piping: Plastic, ABS
Friendly Inspection Services Sample report
Page 9 of 20
Heat/AC
Kitchen / dining area
Water Heater ConditionS A C N/A H
XType: Indirect firedLocation: BasementBecause of diminishing temperatures when multiple fixtures are being used at the sametime, I recommend that you have the hot water system evaluated by a plumber
Water capacityRated capacity: 40 Gallons
MakeMake: SuperStore
T & P valve and vacuum breakerS A C N/A H
XT & P valve and vacuum breaker observed in place
Heater EnclosureS A C N/A H
X
ThermostatsS A C N/A H
XFunctional
Heating systemS A C N/A H
XHeating system type: Oil fired hot water boilerDistribution method: Copper piping
Flue pipe and damperS A C N/A H
XGalvanized flue pipe
Fuel tankS A C N/A H
XEnd outlet tank, recommend that tank additive be used to remove any potential water
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Friendly Inspection Services Sample report
Page 10 of 20
Floor ConditionS A C N/A H
XType of flooring: Vinyl
Window ConditionS A C N/A H
XType of window: Casement
Water temperatureS A C N/A H
XWater temperature: 135 degrees
Sink observationsS A C N/A H
X
PlumbingS A C N/A H
X
CountersS A C N/A H
X
CabinetsS A C N/A H
X
ElectricalS A C N/A H
X
GFCIS A C N/A H
XSome non GFCI receptacles, recommend that all kitchen receptacles be GFCI protected toreduce shock hazard
HVACS A C N/A H
XHeat source: Hot water baseboard
Cook top conditionS A C N/A H
X
Oven & RangeS A C N/A H
X
Friendly Inspection Services Sample report
Page 11 of 20
Laundry
Vent ConditionS A C N/A H
XType: Re-circulating hood with fan
DishwasherS A C N/A H
X
Garbage grinderS A C N/A H
X
RefrigeratorS A C N/A H
X
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Vinyl
DoorsS A C N/A H
X
ElectricalS A C N/A H
X
HeatS A C N/A H
XNone
Cross connectionsCross connections? No
PlumbingS A C N/A H
X
Friendly Inspection Services Sample report
Page 12 of 20
Interior Spaces
1st Floor bath
Basement stairsS A C N/A H
XNot child safe, gap at risers too large • Not child safe, require proper railings
Stairs, railings & handrailsS A C N/A H
XGarage stairs not child safe, require proper railings
Garage stairs not child safe, require proper railingsSmoke Detectors
S A C N/A H
XSmoke and carbon monoxide detectors will be inspected by fire dept. prior to transfer ofproperty
Ceiling conditionS A C N/A H
XType of ceiling: Gypsum board
Wall conditionS A C N/A H
XType of walls: Gypsum board
Floor conditionS A C N/A H
XType of floor: Vinyl
Window conditionS A C N/A H
XType of wiindows: Awning
Friendly Inspection Services Sample report
Page 13 of 20
Door conditionS A C N/A H
X
ElectricalS A C N/A H
X
GFCIS A C N/A H
X
SinksS A C N/A H
XWater temperature: 102 degrees
PlumbingS A C N/A H
X
CountersS A C N/A H
X
CabinetsS A C N/A H
X
Tub / ShowerS A C N/A H
XWater temperature: 102 degrees
Shower wallsS A C N/A H
XType: Fiberglass tub / shower unit
Toilet conditionS A C N/A H
X
Bath exhaust fanS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Friendly Inspection Services Sample report
Page 14 of 20
Master bath
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Vinyl
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
SinksS A C N/A H
XWater temperature: 137 degreesDrain stopper did not operate properly • Consult a plumber
PlumbingS A C N/A H
X
CountersS A C N/A H
X
CabinetsS A C N/A H
X
Tub / ShowerS A C N/A H
XWater temperature: 137 degreesTemperature at tub / shower should not excceed 111 degrees
Shower wallsS A C N/A H
XType: Fiberglass tub / shower unit
Friendly Inspection Services Sample report
Page 15 of 20
Master bedroom
ToiletsS A C N/A H
X
ElectricalS A C N/A H
X
GFCIS A C N/A H
X
Exhaust FanS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Carpet
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
Friendly Inspection Services Sample report
Page 16 of 20
Front bedroom
Rear bedroom
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Carpet
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Friendly Inspection Services Sample report
Page 17 of 20
Living room
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Carpet
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Carpet
Window ConditionS A C N/A H
XType of window: Double hung
Friendly Inspection Services Sample report
Page 18 of 20
Attic
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Exterior doorS A C N/A H
X
Screen DoorsS A C N/A H
X
AccessS A C N/A H
XType of access: ScuttleWalked in attic • Recommend insulating and air sealing old scuttle cover
Recommend insulating and air sealing old scuttle coverAttic structure
S A C N/A H
XFraming type: TrussSheathing material: Plywood
ChimneyS A C N/A H
X
Friendly Inspection Services Sample report
Page 19 of 20
Attic PlumbingS A C N/A H
X
ElectricalS A C N/A H
XNo attic light
Exhaust fan outletsS A C N/A H
XHidden by insulation
FlashingS A C N/A H
XLocations: Chimney • Step flashing • Vent pipes
Insulation ConditionS A C N/A H
XInsulation type: Blown cellulose insulationThickness: 8" • 10"Recommend upgrade to R50
VentilationS A C N/A H
XType: Ridge vent • Soffit venting
Environmental issuesS A C N/A H
XNone observed at time of inspection
Water penetrationS A C N/A H
XNone visible or accessible at time of inspection
Friendly Inspection Services Sample report
Page 20 of 20
Report SummaryReport Summary
Exterior AreasPage 2 Siding Condition • Loose siding observed
Page 3 Bulkhead / walkout • Missing torsion springs
GroundsPage 4 Porches & Decks • No joist supports at outer beam, recommend that proper joist supports
be installed • Recommend that porch deck frame be bolted to houseGaragePage 5 Garage doors &
opener • Electric eye safety system improperly installed • Electric eye units toohigh
ElectricalPage 7 Cable Feeds Cable entry into meter socket needs to be sealed properly , consult a
licensed electricianPage 7 Service panel • Evidence of water in panel • Consult a licensed electrician
Water HeaterPage 9 Water Heater
Condition • Because of diminishing temperatures when multiple fixtures are beingused at the same time, I recommend that you have the hot water systemevaluated by a plumber
Interior SpacesPage 12 Basement stairs • Not child safe, gap at risers too large • Not child safe, require proper
railingsPage 12 Stairs, railings &
handrails • Garage stairs not child safe, require proper railings
Master bathPage 14 Sinks • Drain stopper did not operate properly • Consult a plumber
AtticPage 18 Access • Recommend insulating and air sealing old scuttle cover