Page 1: Fluke Clamp Meters - ElekNet · Industrial Electrical Contractor family: 321 Plant Maintenance Electrical Contractor Working with motors and drives • Measure motor start-up and

Fluke Clamp MetersSolutions for every need

Page 2: Fluke Clamp Meters - ElekNet · Industrial Electrical Contractor family: 321 Plant Maintenance Electrical Contractor Working with motors and drives • Measure motor start-up and

Job functions Applications Key features Recommended Clamp

Electrical Contractor Working on panels and branch circuits•Measureloadsonabranchcircuitatapanel(includingfeedercables,

branch circuits, and neutrals) and the continuity of switches, fuses, and contacts

•Measureloadsidevoltageofabreakerorfuse•Checkifacircuitislivebeforebeginningwork

•OpenJawaccurrentmeasurementto100A•ACandDCvoltage•T5-600:CATIII600Vac/dc•T5-1000:CATIII1000Vac/dc,CATIV600Vac/dc•Continuity,resistance•Ruggedandeasytouse

T5-1000CAT III 1000 VOthers in the family: T5-600Facility Maintenance

Commercial Electrician

Commercial Electrical Contractor Verify circuit integrity and operation•Measureloadcurrent,acvoltageandcontinuityofswitches,fuses,and

contacts

Feeder Cables•Checkbalanceandloadingoffeedercables

•Measureupto400Aac•0.01Aresolutioninthe40Arangeformore

precise measurments•Compactformfactortomakemeasurmentseasily

in tight cable compartments•Measureacanddcvoltageto600V•Resistance,continuity,anddisplayholdfunctions

322CAT III 600 VOthers in the family: 321Industrial Electrical Contractor

Plant Maintenance

Electrical Contractor Working with motors and drives•Measuremotorstart-upandruncurrent•Measuretheoutputofvariablespeedmotorsanddrives

In and around the service panel•Clamparoundbusbarorconductorstomeasureloadsandlinefrequencyin

circuits and feeders

Measure ac or dc current•Measureacordcforuseinbattery-operatedsystemslikeUPSorotherdc

systems

• Inrushcurrentmodeforrepeatablemeasurement ofmotororequipmentstart-upcurrent

•Narrow,elongatedjawwithlargeopeningeasilysingles out the conductor of interest

•True-rmstomoreaccuratelymeasuretheactual current, even with distorted wave-forms caused by noisy loads

• Includeslargebacklitdisplay,frequency,acanddcvoltage, resistance, continuity, and min/max

337CAT III 600 VOthers in the family: 333, 334, 335 and 336

Commercal Electrician

Plant Maintenance

Industrial Electrician

Industrial Service Electrician Service panel, service entrance, and low voltage vaults• Intheservicepanel,clamparoundeachindividualphase.(Goodforlarge

single or parallel conductors)• Intheserviceentrance,clamparoundbusbars,upto2.5in,toverify

expected current usage•Measurecurrentinconductorsoflow-voltagevaults(1000Vorless)

Working with large loads•Verifyoperationoflargeloadservicepanels,switchgears,largecurrent

DC systems, and motors

•Upto2000Adc,1400Aaccurrentmeasurement• Largejawsuitableforsingleormultiplelarge

conductors•CatIV600Vratedformaximumapplication

versatility• Inputsfor600Vac,1000Vdc,400KΩ resistance,

and continuity• Lowpassfilter,min/max/avg,andinrushcurrent•Accuratelymeasurefrequencyofcurrentand

voltage up to 1 kHz

355CAT IV 600 V, CAT III 1000 VOthers in the family: 353

Electrical Contractor

Electric Utility Technician

Marine or Welding Electrician

Facility Maintenance Electrician

HVAC/R Service Technician Checking boilers and furnaces•Capturefluegastemperaturesandperformflamerodtesting

HVAC Motors and drives•Measurestartandrunmotorcapacitors•Troubleshootcompressorelectricalmotorfaults•Measureperformanceofvariablefrequencydrives

Testing electrical performance•Measureload-sideandsupply-sidecurrentandvoltage•Measurecurrentandvoltagephasebalanceon3phasesystems

•Measurecurrentupto600Aacandupto 200 µA dc

•Measuretrue-rmsvoltage,capacitance,resistance,and continuity

•Measurecontacttemperaturewithincluded Type-K temperature probe. (Or measure the outside temperature of a pipe with the 80PK-8 Pipe Clamp Temperature Probe (sold separately))

902 600 V CAT III

Clamp Meter selection chart

Page 3: Fluke Clamp Meters - ElekNet · Industrial Electrical Contractor family: 321 Plant Maintenance Electrical Contractor Working with motors and drives • Measure motor start-up and

Job functions Applications Key features Recommended Clamp

Electrical Contractor Working on panels and branch circuits•Measureloadsonabranchcircuitatapanel(includingfeedercables,

branch circuits, and neutrals) and the continuity of switches, fuses, and contacts

•Measureloadsidevoltageofabreakerorfuse•Checkifacircuitislivebeforebeginningwork

•OpenJawaccurrentmeasurementto100A•ACandDCvoltage•T5-600:CATIII600Vac/dc•T5-1000:CATIII1000Vac/dc,CATIV600Vac/dc•Continuity,resistance•Ruggedandeasytouse

T5-1000CAT III 1000 VOthers in the family: T5-600Facility Maintenance

Commercial Electrician

Commercial Electrical Contractor Verify circuit integrity and operation•Measureloadcurrent,acvoltageandcontinuityofswitches,fuses,and

contacts

Feeder Cables•Checkbalanceandloadingoffeedercables

•Measureupto400Aac•0.01Aresolutioninthe40Arangeformore

precise measurments•Compactformfactortomakemeasurmentseasily

in tight cable compartments•Measureacanddcvoltageto600V•Resistance,continuity,anddisplayholdfunctions

322CAT III 600 VOthers in the family: 321Industrial Electrical Contractor

Plant Maintenance

Electrical Contractor Working with motors and drives•Measuremotorstart-upandruncurrent•Measuretheoutputofvariablespeedmotorsanddrives

In and around the service panel•Clamparoundbusbarorconductorstomeasureloadsandlinefrequencyin

circuits and feeders

Measure ac or dc current•Measureacordcforuseinbattery-operatedsystemslikeUPSorotherdc

systems

• Inrushcurrentmodeforrepeatablemeasurement ofmotororequipmentstart-upcurrent

•Narrow,elongatedjawwithlargeopeningeasilysingles out the conductor of interest

•True-rmstomoreaccuratelymeasuretheactual current, even with distorted wave-forms caused by noisy loads

• Includeslargebacklitdisplay,frequency,acanddcvoltage, resistance, continuity, and min/max

337CAT III 600 VOthers in the family: 333, 334, 335 and 336

Commercal Electrician

Plant Maintenance

Industrial Electrician

Industrial Service Electrician Service panel, service entrance, and low voltage vaults• Intheservicepanel,clamparoundeachindividualphase.(Goodforlarge

single or parallel conductors)• Intheserviceentrance,clamparoundbusbars,upto2.5in,toverify

expected current usage•Measurecurrentinconductorsoflow-voltagevaults(1000Vorless)

Working with large loads•Verifyoperationoflargeloadservicepanels,switchgears,largecurrent

DC systems, and motors

•Upto2000Adc,1400Aaccurrentmeasurement• Largejawsuitableforsingleormultiplelarge

conductors•CatIV600Vratedformaximumapplication

versatility• Inputsfor600Vac,1000Vdc,400KΩ resistance,

and continuity• Lowpassfilter,min/max/avg,andinrushcurrent•Accuratelymeasurefrequencyofcurrentand

voltage up to 1 kHz

355CAT IV 600 V, CAT III 1000 VOthers in the family: 353

Electrical Contractor

Electric Utility Technician

Marine or Welding Electrician

Facility Maintenance Electrician

HVAC/R Service Technician Checking boilers and furnaces•Capturefluegastemperaturesandperformflamerodtesting

HVAC Motors and drives•Measurestartandrunmotorcapacitors•Troubleshootcompressorelectricalmotorfaults•Measureperformanceofvariablefrequencydrives

Testing electrical performance•Measureload-sideandsupply-sidecurrentandvoltage•Measurecurrentandvoltagephasebalanceon3phasesystems

•Measurecurrentupto600Aacandupto 200 µA dc

•Measuretrue-rmsvoltage,capacitance,resistance,and continuity

•Measurecontacttemperaturewithincluded Type-K temperature probe. (Or measure the outside temperature of a pipe with the 80PK-8 Pipe Clamp Temperature Probe (sold separately))

902 600 V CAT III

Speciality clamp meters

Job functions Applications Key features Recommended Clamp

Facility Maintenance Electrician

Measuring leakage current•Checkinsulationconditionandleakageofcircuitsand

systems•Checkforleakageincircuitsandsystemsutilizingfilters

Testing insulation on live circuits•Evaluateinsulationconditiononlivecircuitsvialeakage

current measurements where disconnection is highly inconvenient

•Measurementofleakagecurrentwith3mArangeand1 µA of resolution, for accurate monitoring of insulation erosion

•Broadrangeofmeasurement,from1µAupto60A,forall installation needs

•Advancedshieldingtoensureaccurateresultswhen measuring near other conductors

•Easy-to-carry,pocket-sizedleakagecurrenttesterwithwide 40 mm (1.5 in) jaw size

360*CAT III 300 V

Hospital Electrician

Electrical Contractor

Industrial/Commercial Maintenance Electrician

Grounding and bonding resistance testing•Performgroundlooptestsinareaswhereotherground

resistancetesttechniquesarenotavailable•Testpartsofamulti-groundedsystem•Periodicallyperformquicktestsonsystemgroundsas

part of a regular preventative maintenance program

•Measurefrom0.025Ω to 1500 Ω ground loop resistance.• Largejawforclampingaroundthewidestrangeof

ground conductors or grounding bars•Measuregroundleakageandacloadcurrentsfrom

0.2 mA all the way up to 30 A•Userdefinedalarmlimitsforrapidpass/failtype

measurments

1630CAT III 300 V

Utility Technician

Electrical Contractor/ Consultant

Process Technician/ Electrician

Measuring process control signals•Measures4-20mAsignalswithoutbreakingtheloop•CheckcorrectoperationofPLCsandcontrolsystems

analog I/O

•Savestimeandmoneybyeasilymeasuring4-20mA signals

•Detatchableminiatureclampfortightlocations•Alsomeasureolder10to50mAsignalsystemswiththe

100 mA range•Backlitdisplay,spotlight,displayhold,andzeroreading

buttons

771CAT II 300 V

Automation Specialist/ Commercial Electrician

Electrical and Field Service Technician

Measuring non-linear loads•Setupandtroubleshootvariablefrequencydrivesand

UPS systems—Verify correct operation by measuring key powerqualityparameters

Harmonic measurements•Uncoverharmonicissuesthatcandamageordisrupt

criticalequipment

Troubleshooting start-up current issues •Checkstart-upcurrentwherespuriousresetsor

nuisance circuit breaker tripping occurs

Load studies•Verifyelectricalsystemcapacitybeforeaddingloads

•AC/DCcurrent:Clamp-onmeasurementofcurrentupto1400 A ac rms and 2000 A dc

•Highestsafetyrating:CATIV600Vratedforuseattheservice entrance

•Accurateinnoisyenvironments:Usinglow-passfilter,theclamp meter performs even with distorted waveforms

•Datalogging:Identifyintermittentfaultsbylogginganypowerqualityparameterforminutes,oroveramonth

•Troubleshootharmonics:Analyzeandlogharmonics digitally or graphically

• Inrushcurrent:Captureandanalyzenuisancetripping, from 3 seconds to 300 seconds

345CAT IV 600 V, CAT III 1000 V

HVAC/R Technician

Electrical Engineer

Commercial Electrician

Facility Maintenance Electrician

Electric Utility Engineer

Page 4: Fluke Clamp Meters - ElekNet · Industrial Electrical Contractor family: 321 Plant Maintenance Electrical Contractor Working with motors and drives • Measure motor start-up and

Speciality clamp meters

Need more help choosing a clamp meter to fit your needs? Go interactive! Visit www.fluke.com/clamps and use our on-line selection guide to find the right clamp solution for you!

*Not available for sale in Canada

Job functions Applications Key features Recommended Clamp

Facility Maintenance Electrician

Measuring leakage current•Checkinsulationconditionandleakageofcircuitsand

systems•Checkforleakageincircuitsandsystemsutilizingfilters

Testing insulation on live circuits•Evaluateinsulationconditiononlivecircuitsvialeakage

current measurements where disconnection is highly inconvenient

•Measurementofleakagecurrentwith3mArangeand1 µA of resolution, for accurate monitoring of insulation erosion

•Broadrangeofmeasurement,from1µAupto60A,forall installation needs

•Advancedshieldingtoensureaccurateresultswhen measuring near other conductors

•Easy-to-carry,pocket-sizedleakagecurrenttesterwithwide 40 mm (1.5 in) jaw size

360*CAT III 300 V

Hospital Electrician

Electrical Contractor

Industrial/Commercial Maintenance Electrician

Grounding and bonding resistance testing•Performgroundlooptestsinareaswhereotherground

resistancetesttechniquesarenotavailable•Testpartsofamulti-groundedsystem•Periodicallyperformquicktestsonsystemgroundsas

part of a regular preventative maintenance program

•Measurefrom0.025Ω to 1500 Ω ground loop resistance.• Largejawforclampingaroundthewidestrangeof

ground conductors or grounding bars•Measuregroundleakageandacloadcurrentsfrom

0.2 mA all the way up to 30 A•Userdefinedalarmlimitsforrapidpass/failtype

measurments

1630CAT III 300 V

Utility Technician

Electrical Contractor/ Consultant

Process Technician/ Electrician

Measuring process control signals•Measures4-20mAsignalswithoutbreakingtheloop•CheckcorrectoperationofPLCsandcontrolsystems

analog I/O

•Savestimeandmoneybyeasilymeasuring4-20mA signals

•Detatchableminiatureclampfortightlocations•Alsomeasureolder10to50mAsignalsystemswiththe

100 mA range•Backlitdisplay,spotlight,displayhold,andzeroreading

buttons

771CAT II 300 V

Automation Specialist/ Commercial Electrician

Electrical and Field Service Technician

Measuring non-linear loads•Setupandtroubleshootvariablefrequencydrivesand

UPS systems—Verify correct operation by measuring key powerqualityparameters

Harmonic measurements•Uncoverharmonicissuesthatcandamageordisrupt

criticalequipment

Troubleshooting start-up current issues •Checkstart-upcurrentwherespuriousresetsor

nuisance circuit breaker tripping occurs

Load studies•Verifyelectricalsystemcapacitybeforeaddingloads

•AC/DCcurrent:Clamp-onmeasurementofcurrentupto1400 A ac rms and 2000 A dc

•Highestsafetyrating:CATIV600Vratedforuseattheservice entrance

•Accurateinnoisyenvironments:Usinglow-passfilter,theclamp meter performs even with distorted waveforms

•Datalogging:Identifyintermittentfaultsbylogginganypowerqualityparameterforminutes,oroveramonth

•Troubleshootharmonics:Analyzeandlogharmonics digitally or graphically

• Inrushcurrent:Captureandanalyzenuisancetripping, from 3 seconds to 300 seconds

345CAT IV 600 V, CAT III 1000 V

HVAC/R Technician

Electrical Engineer

Commercial Electrician

Facility Maintenance Electrician

Electric Utility Engineer

Page 5: Fluke Clamp Meters - ElekNet · Industrial Electrical Contractor family: 321 Plant Maintenance Electrical Contractor Working with motors and drives • Measure motor start-up and

Clamp meters designed for the way you work.

See our full line of Fluke Accessories at www.fluke.com/accy-catalog

Commercial/industrial electrician

Residential/commercial electrician

General purpose Industrial electrician HVAC/R High end industrial, utility Leakage Process Earth ground Power quality

T5-600 T5-1000 321 322 333 334 335 336 337 902 353 355 360* 771 1630 345

MeasurementsAC current • • • • • • • • • • • • • • •AC volts • • • • • • • • • • • •Resistance • • • • • • • • • • •Continuity • • • • • • • • • • • •DC Volts • • • • • • • • • • •DC current • • • • • •True-rms • • • • • • • •Frequency • • • •Min/Max/Avg • • • • •4-20 mA (0.01 mA resolution) •Temperature •Capacitance •Earth ground loop resistance •Special featuresInrush current mode • • • • • • •Low Pass filter • • •Harmonics, power, and data logging

DisplayDisplay hold • • • • • • • • • • • • • • • •Backlight • • • • • • • • •Graphing display •Specifications

Jaw opening 12.9 mm (0.5 in) 12.9 mm (0.5 in) 25.4 mm (1.0 in) 25.4 mm (1.0 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 58 mm (2.3 in) 58 mm (2.3 in) 40 mm (1.5 in) 4.5mm (0.177 in) 35 mm (1.38 in) 58 mm (2.3 in)Max wire size 1/0 THHN Cable 1/0 THHN Cable 500 MCM 500 MCM 750 MCM 750 MCM 750 MCM 750 MCM or two

500 MCM750 MCM or two

500 MCM750 MCM 750 MCM or three

500 MCM750 MCM or three

500 MCM1250 MCM 6 AWG 1000 MCM 750 MCM or three

500 MCMCurrent range ac rms 0 to 100 A 0 to 100 A 0 to 400 A 0 to 400 A 0 to 400 A 0 to 600 A 0 to 600 A 0 to 600 A 0 to 999.9 A 0 to 600 A 0 to 1400 A 0 to 1400 A 0 to 60 A 0 to 35 A 0 to 1400 AAccuracy ac current (50/60 Hz) 3 %

± 3 counts3 %

± 3 counts1.8 %

± 5 counts1.8 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts1.5 %

+ 5 counts1.5 %

+ 5 counts1 %

+ 5 counts2 %

∓ 3 counts± 3 %

± 5 countsAC Response Averaging Averaging Averaging Averaging Averaging Averaging True-rms True-rms True-rms True-rms True-rms True-rms Averaging True-rms True-rmsCurrent range dc 0 to 600 A 0 to 999.9 A 0 to 200 µA 0 to 2000 A 0 to 2000 A 0 to 99.9 mA 0 to 2000 AAccuracy dc current 2 %

+ 3 counts2 %

+ 3 counts1 %

± 5 counts1.5 %

+ 5 counts1.5 %

+ 5 counts4-20 mA is 0.2 %

+ 5 counts± 1.5 %

± 5 countsVoltage range ac 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 600 V 0 to 600 V 0 to 825 V

Accuracy ac voltage 1.5 % ± 2 counts

1.5 % ± 2 counts

1.2 % + 5 counts

1.2 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % ± 5 counts

1 % + 5 counts

± 1 % ± 5 counts

Voltage range dc 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 1000 V 0 to 825 VAccuracy dc voltage 1 %

± 1 count1 %

± 1 count1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

± 5 counts1 %

+ 5 counts± 1 %

± 5 countsResistance range 0 to 1000 Ω 0 to 1000 Ω 0 to 400 Ω 0 to 400 Ω 0 to 600 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 9999 Ω 0 to 400 KΩ 0 to 1500 ΩFrequency measurement range 5 to 400 Hz 5 to 1000 Hz 5 to 1000 Hz 15 to 1000 HzUnit powerAuto off • • • • • • • • • • • • • • • •Warranty and safetyWarranty (years) 2 2 2 2 3 3 3 3 3 3 3 3 1 3 1 2

Category ratings (EN61010-1) CAT III 600 V CAT IV 600 V, CAT III 1000 V

CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V

CAT IV 600 V, CAT III 1000 V

CAT III 300 V Cat II 300 V CAT III 300 V CAT IV 600 V, CAT III 1000 V

*Not available for sale in Canada

Page 6: Fluke Clamp Meters - ElekNet · Industrial Electrical Contractor family: 321 Plant Maintenance Electrical Contractor Working with motors and drives • Measure motor start-up and

Clamp meters designed for the way you work.

Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.

Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands

Fluke. Keeping your world up and running.®

For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866

From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com

©2008 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 8/2008 3363537 B-EN-N Rev A

Modification of this document is not permitted without written permission from Fluke Corporation.

Commercial/industrial electrician

Residential/commercial electrician

General purpose Industrial electrician HVAC/R High end industrial, utility Leakage Process Earth ground Power quality

T5-600 T5-1000 321 322 333 334 335 336 337 902 353 355 360* 771 1630 345

MeasurementsAC current • • • • • • • • • • • • • • •AC volts • • • • • • • • • • • •Resistance • • • • • • • • • • •Continuity • • • • • • • • • • • •DC Volts • • • • • • • • • • •DC current • • • • • •True-rms • • • • • • • •Frequency • • • •Min/Max/Avg • • • • •4-20 mA (0.01 mA resolution) •Temperature •Capacitance •Earth ground loop resistance •Special featuresInrush current mode • • • • • • •Low Pass filter • • •Harmonics, power, and data logging

DisplayDisplay hold • • • • • • • • • • • • • • • •Backlight • • • • • • • • •Graphing display •Specifications

Jaw opening 12.9 mm (0.5 in) 12.9 mm (0.5 in) 25.4 mm (1.0 in) 25.4 mm (1.0 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 30.5 mm (1.2 in) 58 mm (2.3 in) 58 mm (2.3 in) 40 mm (1.5 in) 4.5mm (0.177 in) 35 mm (1.38 in) 58 mm (2.3 in)Max wire size 1/0 THHN Cable 1/0 THHN Cable 500 MCM 500 MCM 750 MCM 750 MCM 750 MCM 750 MCM or two

500 MCM750 MCM or two

500 MCM750 MCM 750 MCM or three

500 MCM750 MCM or three

500 MCM1250 MCM 6 AWG 1000 MCM 750 MCM or three

500 MCMCurrent range ac rms 0 to 100 A 0 to 100 A 0 to 400 A 0 to 400 A 0 to 400 A 0 to 600 A 0 to 600 A 0 to 600 A 0 to 999.9 A 0 to 600 A 0 to 1400 A 0 to 1400 A 0 to 60 A 0 to 35 A 0 to 1400 AAccuracy ac current (50/60 Hz) 3 %

± 3 counts3 %

± 3 counts1.8 %

± 5 counts1.8 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts2 %

± 5 counts1.5 %

+ 5 counts1.5 %

+ 5 counts1 %

+ 5 counts2 %

∓ 3 counts± 3 %

± 5 countsAC Response Averaging Averaging Averaging Averaging Averaging Averaging True-rms True-rms True-rms True-rms True-rms True-rms Averaging True-rms True-rmsCurrent range dc 0 to 600 A 0 to 999.9 A 0 to 200 µA 0 to 2000 A 0 to 2000 A 0 to 99.9 mA 0 to 2000 AAccuracy dc current 2 %

+ 3 counts2 %

+ 3 counts1 %

± 5 counts1.5 %

+ 5 counts1.5 %

+ 5 counts4-20 mA is 0.2 %

+ 5 counts± 1.5 %

± 5 countsVoltage range ac 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 600 V 0 to 600 V 0 to 825 V

Accuracy ac voltage 1.5 % ± 2 counts

1.5 % ± 2 counts

1.2 % + 5 counts

1.2 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % + 5 counts

1 % ± 5 counts

1 % + 5 counts

± 1 % ± 5 counts

Voltage range dc 0 to 600 V 0 to 1000 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 600 V 0 to 1000 V 0 to 825 VAccuracy dc voltage 1 %

± 1 count1 %

± 1 count1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

+ 5 counts1 %

± 5 counts1 %

+ 5 counts± 1 %

± 5 countsResistance range 0 to 1000 Ω 0 to 1000 Ω 0 to 400 Ω 0 to 400 Ω 0 to 600 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 9999 Ω 0 to 400 KΩ 0 to 1500 ΩFrequency measurement range 5 to 400 Hz 5 to 1000 Hz 5 to 1000 Hz 15 to 1000 HzUnit powerAuto off • • • • • • • • • • • • • • • •Warranty and safetyWarranty (years) 2 2 2 2 3 3 3 3 3 3 3 3 1 3 1 2

Category ratings (EN61010-1) CAT III 600 V CAT IV 600 V, CAT III 1000 V

CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V

CAT IV 600 V, CAT III 1000 V

CAT III 300 V Cat II 300 V CAT III 300 V CAT IV 600 V, CAT III 1000 V

*Not available for sale in Canada