flexi multiradio bts commissioning and integration.ppt new

24
Flexi Multi-radio BTS Commissioning and Integration Connect via LMP on ESMx using Ethernet cable Setup the local IP address on PC under Internet Protocol (TCP/IP) properties as follow: IP address: 192.168.255.130 Subnet Mask: 255.255.255.128 Default Gateway: none Personal Firewall may need to allow access to local network e.g. Zone Alarm The default settings of the BTS are: IP address: 192.168.255.131 2G Flexi BTS Site Manager connection TCP Port: 27500 2G Flexi BTS Site Manager SW download via TCP Port: 27501

Upload: faiz2009

Post on 25-Nov-2015

358 views

Category:

Documents


42 download

TRANSCRIPT

  • Flexi Multi-radio BTS Commissioning and IntegrationConnect via LMP on ESMx using Ethernet cableSetup the local IP address on PC under Internet Protocol (TCP/IP) properties as follow:IP address:192.168.255.130Subnet Mask:255.255.255.128Default Gateway: nonePersonal Firewall may need to allow access to local network e.g. Zone AlarmThe default settings of the BTS are: IP address: 192.168.255.1312G Flexi BTS Site Manager connection TCP Port: 275002G Flexi BTS Site Manager SW download via TCP Port: 27501

  • Local Commissioning Flexi 2G BTS Site Manager (2/2)IP address of System Module, and Password just keep empty

  • Local CommissioningCommissioning WizardSelect the Commissioning Wizard menu item or click the Commissioningbutton on the View Selection Bar.

  • Local CommissioningUndo Commissioning (1/4)to revert the site to un-commissioned mode and he can also check the option that whether user wants to erase bypass capacity along with it or no.This button is disabled in remote connection

  • Local CommissioningUndo Commissioning (2/4)

  • Local CommissioningUndo Commissioning (3/4)Indicate the BTS has successfully uncommissioned

  • Local Commissioning Commissioning ManuallyIn this example, user do commissioning manually

  • Local Commissioning Site Specific InformationNavigation tree - Enables user to navigate any screen, and update/view parameters corresponding to that screen. Data persistence is maintained across screen navigations

  • Local Commissioning Hardware ConfigurationIf user has hardware template file (.epb or SCF file), specify from file can be selectedIn this example specify manually is selected]

  • Local Commissioning Hardware Configuration Module Configurationconfigure various radio modules, synchronization master, and radio masters

  • Local CommissioningHardware Configuration Local Sector settingconfigure and associate antennas of only one type of RF unit (RM) to a particular local sector and specify per TRX power

  • Local Commissioning Hardware Configuration Antenna SettingsSelect the antenna line settings, specify MHA settings, provide information for feeder voltage, feeder loss, VSWR minor and major limits for the selected antenna

  • Local Commissioning Hardware Configuration RFM EAC settingsconfigure the external alarm lines associated with the individual FRMs

  • Local CommissioningTransmission Parameter

  • Enable satellite

  • Local CommissioningTransmission Parameter Synchronization (Source)

  • Local Commissioning Transmission Parameter LIF Setting

  • Local Commissioning Transmission Parameter Abis Termination

  • Local Commissioning Transmission Parameter Abis Allocation

  • Local CommissioningCross Connection Q1 Management

  • Local CommissioningSCF preview - SummaryFrom this summary, user can check whether the commissioing step has been completed. This can be checked by looking at the indication color of each step, green means ok, red means not complete

  • Local CommissioningCommissioning completeted

  • Local Commissioning Tracing the traffic during the test callFrom the toolbar select Test menu select Traffic trace select cell would be traced --> click Automatic Update (if necessary) For the CS call, yellow color indicates the RTSL that being occupied

  • Sanjaya kumarIdea cellular Ltd.Mo.98370897