02 ra22714en01gla0 flexi multiradio installation
TRANSCRIPT
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 1/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
1
For internal use only
RA22714EN01GLA01 © N okia Siemens Networks
Flexi Multiradio BTS GSM/EDGEInstallation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 2/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
2
For internal use only
RA22714EN01GLA02 © N okia Siemens Networks
Nokia Siemens NetworksAcademy
Legal notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks trainingdocumentation, product documentation and slide presentation material, all of which are forthwithknown as Nokia Siemens Networks training material, are the exclusive property of NokiaSiemens Networks. Nokia Siemens Networks owns the rights to copying, modification,translation, adaptation or derivatives including any improvements or developments. NokiaSiemens Networks has the sole r ight to copy, distribute, amend, modify, develop, license,sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individualscan use the Nokia Siemens Networks training material for their own personal self-developmentonly, those same individuals cannot subsequently pass on that same Intellectual Property toothers without the prior written agreement of Nokia Siemens Networks. The Nokia SiemensNetworks training material cannot be used outside of an agreed Nokia Siemens Networkstraining session for development of groups without the prior written agreement of NokiaSiemens Networks.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 3/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
3
For internal use only
RA22714EN01GLA03 © N okia Siemens Networks
Objectives (1/2)
After completing this module, the participant will be able to:
Theory:
• Describe the general work order of installing Flexi Multiradio BTS GSM/EDGE
• Describe the installation option for Flexi Multiradio BTS GSM/EDGE
• List the installation tools needed for Flexi Multiradio BTS GSM/EDGE
• Explain the installation order for stack, wall and pole installation option
• Explain the installation order of cabinet for outdoor and cabinet for indoor installation option
• Describe how to install the modules for different installation options
• Identify the installation of optional items.
• Identify the interfaces and connectors of the Flexi Multiradio BTS GSM/EDGE modules andTransport sub-modules in respect to configuration
• Describe the cabling principle for different installation options
• Explain the feederless solution for Flexi Multiradio BTS GSM/EDGE
• Describe the antenna system for Flexi BTS GSM/EDGE
• Describe the example of installation of common configuration for different installation options.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 4/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
4
For internal use only
RA22714EN01GLA04 © N okia Siemens Networks
Objectives (2/2)
After completing this module, the participant will be able to:…. (Cont’d)
Practical:
• Checking the content delivery and optional items based on specific installation option
• Install the module for Flexi Multiradio BTS GSM/EDGE based on specific installation option
and configuration.
• Install the optional items needed for Flexi Multiradio BTS GSM/EDGE
• Flexi Multiradio BTS GSM/EDGE Module and Transport Module Cabling
• Examine for correctly installed the Flexi Multiradio BTS GSM/EDGE for stack, wall, pole,
indoor and outdoor cabinet installation options based on checking list
• Demonstrate correctly install, route cables and optical fibers on the Flexi Multiradio BTSGSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 5/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
5
For internal use only
RA22714EN01GLA05 © N okia Siemens Networks
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 6/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 7/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
7
For internal use only
RA22714EN01GLA07 © N okia Siemens Networks
Flexi Multiradio BTS GSM/EDGEInstallation
Preparation of Flexi Multiradio BTS GSM/EDGE installation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 8/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
8
For internal use only
RA22714EN01GLA08 © N okia Siemens Networks
1. Check the tools
2. Unpack the delivery and handle the modules
3. Fix adapter mechanics to the plinth (wall & pole installations)
4. Install the plinth (stack, wall & pole installations) or cabinet
5. Ground the plinth or cabinet
6. Install the casings to the plinth
7. Install transmission sub-module
8. Install the modules
9. Install optional modules
10. Connect the cables
11. Connect external power feed12. Install module front covers
Preparation of InstallationGeneral work order
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 9/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
9
For internal use only
RA22714EN01GLA09 © N okia Siemens Networks
When handling the modules, always usethe antistatic wrist strap as shown in thefigure below. The cabinet must begrounded, otherwise the antistatic wriststrap will not work. Refer to Grounding theBTS section.
ESD ANTI-STATIC WRIST STRAPSSHOULD BE WORN WHEN
HANDLING ANY UNIT WHICH
DISPLAYS THE ESD LOGO
ESD ANTI-STATIC WRIST STRAPSSHOULD BE WORN WHEN
HANDLING ANY UNIT WHICHDISPLAYS THE ESD LOGO
Preparation of InstallationHandling the modules and unpacking the delivery
NOTE: wrist strap not included in the Flexi EDGE BTS deliveries
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 10/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
10
For internal use only
RA22714EN01GLA01 0 © N ok ia Si em en s N et wo rk s
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 11/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 12/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
12
For internal use only
RA22714EN01GLA01 2 © N ok ia S ie mens Ne tw or ks
Poleinstallation
Stackedinstallation
Flexi Multiradio BTS GSM/EDGE InstallationOption
Wallinstallation
Nokia, 3rd partyBTS cabinet orSSS installation
U p t o 2 0 0 * m e t e r s
Urban feederless site application
* Up to 40KM with Single mode fiber
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 13/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
13
For internal use only
RA22714EN01GLA013 © N ok ia S ie me ns N et wo rk s
Flexi Multiradio BTS GSM/EDGE InstallationOption - Tower or mast installation
BTS modules installed on top ofmast or tower
• A pole installations
BTS modules installed on base ofmast or tower
• A stack or outdoor cabinetinstallation
• LTE space and optional BBU incabinet
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 14/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
14
For internal use only
RA22714EN01GLA014 © N ok ia S ie me ns N et wo rk s
Flexi Multiradio BTS GSM/EDGE InstallationOption - Other installation options
“Street furniture” installation “Hidden” installation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 15/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 16/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 17/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
17
For internal use only
RA22714EN01GLA01 7 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGEInstallation
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole(SWP) Installation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 18/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
18
For internal use only
RA22714EN01GLA01 8 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE Stack, Wall, andPole (SWP) Installation – General Procedure
Content ofDelivery
Clearances
Installing thePlinth
Grounding theplinth
Installing thecasings
Installing themodules
Grounding the
modules
Cabling
Power up and
commissioningthe BTS
Installingmodule front
covers
1
2
3
4
5
6
7
8
9
10
C h e c k i n g
I n s
t a l l a t i o n
C a b l i n g
C o m m i s -
s i o n i n g
F r o n t
p a n e l
Start
Plinton the floor,wall, or pole
GroundingPrinciple
Casing installationprinciple
Module installationprinciple
Grounding principle
Installation example
Cable routing andcable ties
External power
Internal power cables
Antenna cables
Optical cables
Transmission & alarmcable
Finish
General procedure of Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole
(SWP) Installation :
1. Unpack and check the delivery.
2. Check Clearance
3. Installing the plinth
• For wall or pole installation, the adapter mechanics must be fixed to the
plinth beforehand. But it’s not applicable if you are installing version
FMFA v.104 of the plinth
• The procedure of installing the plinth could be of of following:
• Anchoring the plinth on the floor .
• Mounting the plinth on a wall.
• For mounting the plinth on the pole, see:
• Mounting the plinth on a pole with VMPB or
• Mounting the plinth on the pole with FPKA
4. Grounding the plinth
5. and 6. Installing the casings, modules, and cable entries
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 19/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 20/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
20
General procedure of Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole
(SWP) Installation: …… (cont’d)
7. and 8. Grounding the modules and connecting cablesCabling principles:
• Cabling principles in stacked, wall and pole installation
• Cable clamps in stacked, wall and pole installation
• Optional cable tunnels
• Internal power cabling principles for System Module (ESMB/C)
The order to connect the cables is as follows:
a) Grounding cables
b) 48 V DC power feedc) Internal power cables
d) Antenna jumper cables
e) Optical cables (OPT)
f) Transmission cables. See one of the following:
• Connecting FIEA, FIPA, FIQx and FIYx transmission cables
without optical transceiver
• Connecting FIQx and FIYx transmission cables with optical
transceiver
• Connecting FIFA transmission cables
g) Optional cables. See the following instructions in document Installing
Multiradio BTS GSM/EDGE Optional Items:
• Flexi Power Alarm (FPA) cables
• External alarms and controls (EAC) cables
• Synchronisation cables
• Local management port (LMP) cables
• Location Management Unit (LMU) cables
• Optional Rx Out (RxO)
h) In stack or pole installation, install side cable tunnels (optional). See
Installing optional side cable tunnels in document Installing Multiradio
BTS GSM/EDGE Optional Items:
9. Power up and Commissioning
10. Installing module front covers
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 21/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
21
For internal use only
RA22714EN01GLA02 1 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationContent of Delivery – System Module (ESMB/ESMC)
2M10 Cableterm (25/35 mm2) Ring
1Pull-out tool
2B10 washer
1Bag Reclosable (15 0 x 2 25/ 20 0 x 260) 0.1 mm
2M10 Hex Nut
ESMC
ESMB
Version
2 AWG Single cable terminal lug rubber boots
472059
472109
1Flexi Multiradio BTS GSM/EDGE Syst em ModuleSystem Module
QuantityProductCode
Contents of deliveryDelivery
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 22/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
22
For internal use only
RA22714EN01GLA02 2 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationContent of Delivery – Transmission Sub-Module
4 71719AFlexi tra nsmission sub-module (FIYA)
PW 100Base-T ethernet(RJ48) +
4xE1/T1 symmetrical 120/100ohm (RJ5) + optional opticalGE (SFP)
4 70248AFlexi transmission interfaceE1/T1 symmetricalsubmodule (FIPA)
4 71607AFlexi transmission sub-module (FIQA)
PW 100Base-T ethernet(RJ48) +
4xE1/T1 symmetrical 120/100ohm (RJ5) + optional optical
GE (SFP)
Flexi trasnsmission interfaceFlexbus sub-module (FIFA)
Flexi transmission interfaceE1submodule (FIEA)
Version
4Screws(preinstalled)
4 71007A
4 70247A
1Transmissionsub-module
SystemModule
Quantity
ProductCode
Contentsof delivery
Delivery
Transmission Submodule
FIPA
FIEA
FIFA
FIQA
FIYA
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 23/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 24/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 25/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
25
For internal use only
RA22714EN01GLA02 5 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationContent of Delivery – Pole Mounting Kit (optional)
6Module fixingscrews
2Bolt restrainer
FPKA
Version
2 Assemblingbolts
2 Aluminiumcastings
4 71649AFlexi PoleMounting Kit
Pole mounting kit
(optional)
Quan-tity
ProductCode
Contentsof delivery
Delivery
Check List
Deliveries are complete.
Equipment is not damaged.
Pole Mounting Kit (optional)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 26/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
26
For internal use only
RA22714EN01GLA02 6 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationClearances
Wallinstallation
Stackinstallation
Wallinstallation
Note:
• In a stack, theminimum sideclearance is 75 mm(3 in.).
• The recommendedclearance for handtying is 150mm (5.9in.)
Check List
Site meets theminimumclearances.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 27/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
27
For internal use only
RA22714EN01GLA02 7 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Plinth on the floor
Plinth on the floor
1. Check the clearancesaround the plinth.
2. Turn the rear stopper.
3. Place the plinth on thefloor, grounding pointsfacing forward.
4. Bolt on the floor with 4bolts, 12 mm (0.47 in.) indiameter. Tighten to 49.0Nm (36.1 ft-lb)
Purpose
The plinth is mandatory when the modules are not mounted in an optional cabinet or
19“ rack.
Before you start
•When choosing the location for the plinth, take into consideration the required
maintenance space. For fan maintenance from the back, 500 mm (19.7 in.) back
space with side access is required.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 28/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
28
For internal use only
RA22714EN01GLA02 8 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Plinth on the floor
Other options for anchoring the plinth are
No wall nearby
Minimum clearanceon the back side
Purpose
The plinth is mandatory when the modules are not mounted in an optional cabinet or
19“ rack.
Before you start
•When choosing the location for the plinth, take into consideration the required
maintenance space. For fan maintenance from the back, 500 mm (19.7 in.) back
space with side access is required.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 29/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 30/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
30
For internal use only
RA22714EN01GLA03 0 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Plinth on the Wall
• If second plinthinstalled, requiredspace between theplinths is 100 mm.
• One mounting plinthper two modules isinstalled on a wall.
Ground
Antenna
CAUTION: Install the modules with
front panels facing left or right. Do not
install modules so that the front panelsface up or down.
If you are going to install Flexi Power Module (FPMA), it should be installed on the
same plinth with the ESMB system module
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 31/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
31
For internal use only
RA22714EN01GLA03 1 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Mounting kit for Plinth on the Pole
There are two pole mounting kitsavailable for mounting the plinthand modules on a pole:
• Pole Mounting Kit (VMPB),for pole between 60 mm (2.4in.) and 120 mm (4.7 in.) indiameter
• Flexi Pole Mounting Kit(FPKA), for pole between 60mm (2.4 in.) and 300 mm(11.8 in.) in diameter
Pole Mounting Kit (VMPB)
Flexi Pole Mounting Kit (FPKA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 32/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
32
For internal use only
RA22714EN01GLA03 2 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Mounting Plinth on the Pole with FPKA (1/2)
• The Flexi Pole Mounting Kit (FPKA) can be used with poles :
• between 60 mm (2.4 in.) and 120 mm (4.7 in.) in diameter.
• The most commonly used size is 80 mm (3.1 in.).
• The FPKA can replace the VMPB Pole Mounting kit in installations where the polediameter is less than 120 mm (4.7 in.).
• The product code of Flexi Pole Mounting Pole (FPKA) is 471649A.
• The maximum allowed weight on the FPKA is 160 kg (352.7 lbs). However, eachFMFA can support a maximum weight of 50 kg (110.23 lbs).
2Bolt M10 x120 105 mmthread ISO 4762 (DIN912)
6Bolt M8 x 20
2Bolt restrainer
1FPKA bracket strainer
FPKA Bracket
Item
1
Quantity
FPKA delivery contentsFlexi Pole Mounting Kit (FPKA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 33/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
33
For internal use only
RA22714EN01GLA03 3 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Mounting Plinth on the Pole with FPKA (2/2)
1. Fix the upper mounting bracket on thepole. Attach the mounting bracket screws(M10) on the bracket. Tighten screws to30 Nm.
2. Fix one side of the lower pole mountingbracket on the plinth with mounting screws(M8). Tighten screws to 20 Nm.
3. Lift the plinth on the pole and fit it to themounting screws of the pole mountingbracket. Tighten screws (M8) to 20 Nm.
4. Place the counterpart of the lower polemounting bracket in its place. Tightenscrews (M10) to 30 Nm.
5. If a second plinth is required, install it onthe other side of the pole mountingbracket.
6. Ground the plinth to the site main ground.
1 2
34
5 6
30 NmNote that the length of mounting screws depends on thediameter of the pole.
Check List
Plinth is installed according toinstructions.
Plinth is level.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 34/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 35/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
35
For internal use only
RA22714EN01GLA03 5 © N ok ia Sie men s Ne tw or ks
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Mounting Plinth on the Pole with VMPB
• There are 3 different lengths of
bolts available and 4 places for
bolts in the pole mounting
brackets.
• When attaching the brackets to
the pole, use the shortest
possible bolts and the holes
whose distance is the closest to
the pole diameter. See the table
and figure for more details.
• A plinth is required for mounting
the modules on a pole. In poleinstallation, the maximum
number of modules on a plinth is
two.
3300211 -255
4300256 -300
212095 - 125
1200126 -165
2200166 -210
60 - 90
Polediameter
(mm)
1120
Hole number*Bolt length
(mm)
* Hole numbering is presented in the figurebelow
If the configuration has more than two modules, additional plinths must be
installed.
Max two 3HU modules.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 36/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
36
For internal use only
RA22714EN01GLA03 6 © N ok ia Sie men s Ne tw or ks
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Mounting Plinth on the Pole with VMPB
Note: with two plinths on
opposite sides, the upper adapter
still has to be up facing a similar
adapter on the other side.
1
2
3
4
7
Detail explanation of each
step, can be seen on notes
page
5
6
Steps
1. Fix the upper mounting bracket on the pole and attach the mounting screws on bracket.
Make sure that the mounting screws in the upper mounting bracket are in the loweredge of the bracket.
2. Fix one half of the lower mounting bracket on the plinth with the mounting screws. Make
sure that the mounting screws in the lower mounting bracket are in the upper edge of
the bracket.
3. Lift the plinth on the pole and fit it to the pole mounting bracket's mounting screws.
4. Tighten the mounting screws.
5. Place the counterpart of the lower pole mounting bracket in its place and tighten the
screws.
6. Make sure that the plinth is not twisted. When the plinth is in a correct position,
tighten the 3 screws in the lower bracket of the adapter mechanics.
7. If a second plinth is required, install it on the other side of the pole mounting bracket.
a) Fix the adapter mechanics on the plinth as described in step 1 above.
b) Fix mounting screws on the upper pole mounting bracket.
c) Lift the plinth on the pole, fit it to the pole mounting bracket's mounting screws
and tighten the screws.
d) Insert the lower fixing screws to fix the plinth on the lower pole mounting
bracket. Tighten the mounting screws.
e) Make sure that the plinth is not twisted. When the plinth is in a correct position,
tighten the remaining 2 screws in the lower bracket of the adapter mechanics.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 37/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
37
For internal use only
RA22714EN01GLA03 7 © N ok ia Sie men s Ne tw or ks
• In a pole installation, one plinth can
have a maximum of two modules
installed. If the configuration has
more than two modules, additional
plinths must be installed.
• Two plinths can be installed on one
pair of mounting brackets (on
opposite sides of the pole).
• The modules must be installed with
front panels facing left or right. Do
not install modules so that the front
panels face up or down.
• Installation order varies by
configuration. See the figure.
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling the Plinth – Example installation on Pole
FXxA
FXxAFXxA
ESMB/ESMC*
ESMB/ESMC
FPMA /FPDA
FXxA FXxA
ESMB/ESMC*
3+3+3 (60 W) ….
12+12+12 (15 W)
configuration on a pole
without FPDA/FPMA)
2+2+2 (60 W) ….
12+12+12 (10 W)
configuration on a pole
with FPDA/FPMA
Note :
* ESMC is used if number of TRX morethan 18 (up to 36) per BCF
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 38/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
38
For internal use only
RA22714EN01GLA03 8 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationGrounding the plinth
1. Ground the plinth to the sitemain ground. Tighten to 8.0-10.0Nm (5.9-7.37 ft-lb)
2. Connect the wrist strap.
Check List
Local grounding (earthing) regulations are followed.
Antistatic wrist strap is used when handling modules.
Plinth is grounded.
Grounding the plinth(FMFA v. 104 or higher)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 39/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
39
For internal use only
RA22714EN01GLA03 9 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Casing – on Stack
Note:
• The casings are pre-installed with back covers.
• In Earthquake Zone 4, the maximum number ofmodules for stack installations is five.
• In Earthquake Zone 4, install side fixing plates onthe casings
• In Earthquake Zone 2, the maximum allowed heightfor a stack is 22U.
• In pole and wall installations, the maximummodules per plinth is two.
• In pole and wall installations, maintenance strapsmust be installed in the casings.
• M5 X 6 screws should be secured with threadlocking compound in pole and wall installations
1
2
3
4
1. Align the holes of the first casing bottomwith the fixing studs on the plinth
2. Push the casing back until it stops.
3. Attach the casing to the plinth with M5 X 6mm screws (6150188). Tighten to 3.5-4.2Nm (2.58-3.10 ft-Ib)
4. Install the remaining casings as requiredby the configuration
Check List
Back covers are properly installed.
Fixing screws are tightened.
Optional: In pole and wall installations,maintenance straps are installed in the frontcovers.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 40/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
40
For internal use only
RA22714EN01GLA04 0 © N ok ia Sie men s Ne tw or ks
Note:
Line up the locating marks in the
module to help aligning the holes
with fixing studs.
1
3
Line up thelocating marks
Line up thelocating marks
24
7
Line up thelocatingmarks 10
8
6
9
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Casing – mounting casing/module on a wall/pole
1
23
4
5
6
8
9
10
Detail explanation of each
step, can be seen on notes
page
TIP:
You can pre-assemble the plinth with two modules on the ground and then lift theentire plinth. This is the easiest method especially in pole installation.
You can also install the casings into the plinth first and then slide the modules in the casings:
Steps
1. Align the holes on the first module's bottom with the fixing studs on the plinth.Tip : Line up the locating marks in the module to help aligning the holes with fixing studs.
2. Push the module back until it stops.
3. Attach the module casing to the plinth with screws.
4. Connect the module grounding cable between the module front panel and theplinth.
5. Align the holes on the second module's bottom with the fixing studs on the firstmodule. Tip :Line up the locating marks in the module to help aligning the holes withfixing studs.
6. Push the module back until it stops.
7. Attach the module casings to each other with screws and spring washers. Securethe screws with glue.
8. Connect the module grounding cable between the module front panel and theplinth.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 41/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
41
For internal use only
RA22714EN01GLA04 1 © N ok ia Sie men s Ne tw or ks
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Casing – Lifting Standalone BTS
• Plinth can be pre-assembled withtwo modules on the ground andthen lift the entire plinth.
• This is the easiest method especiallyin pole installation.
• However, user can lift and mount theplinth first and then install themodules and connect cables,similarly as in stack installation.
Lifting a standalone BTS
Steps:
1. Attach the lifting eye bolts to the attachment points in the plinth. Lifting eye bolts
(M12) are not included in the delivery. You can order the LEKA kit separately from your
NSN supplier.
2. Attach the hoisting belt or the rope to the lifting eye bolts. Attach the hoisting belt
or rope so that the angle between the belt or rope and the plinth is minimum 60°. The
distance between the plinth and the belt or rope is minimum 400 mm (15.6 in.).
3. Lift the BTS carefully to the desired installation height.
4. Mount the BTS.
5. Remove the lifting equipment.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 42/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
42
For internal use only
RA22714EN01GLA04 2 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules
Note:
• In pole and wall installations, install the maintenancestrap for back covers.
• In pole and wall installations, screws are securedwith thread locking compound.
1. Slide the RF module and the SystemModule into the casings.
2. Attach the module(s) to the casingwith M5 X 10 mm screws. Tighten to
3.5-4.2 Nm (2.58-3.10 ft-Ib).
3. Install the transmission sub-moduleto the System Module. Tighten to2.7-3.3 Nm (1.99-2.43 ft-Ib).
4. Install the cable entries on bothcasings. Torque 3.5 to 4.2 Nm.
1
2
3 4
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 43/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
43
For internal use only
RA22714EN01GLA04 3 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules – on wall (1/2)
2
3
5
6
4
7
9
10
1. If the Power Module (FPMA) or PowerDC/DC 24V Module (FPDA) is installed,attach the back covers to the casings.
2. Align the holes on the first casing’s bottomwith the fixing studs on the plinth.
3. Push the casing back until it stops.
4. Attach the casing to the plinth with M5 x 6mm (0.2 in.) screws (6150188) using thread-locking compound and tighten.
5. Align the holes on the second casing’sbottom with the fixing studs on the firstcasing.
6. Push the casing back until it stops.
7. Attach the casings to each other with M5 x 6mm (0.2 in.) screws using thread-locking
compound and tighten8. Repeat steps 2-7 to install the remaining
casings to separate plinths.
9. Slide the module into the casing.
10. Attach the module(s) to the casing with M5 x25 mm (1.0 in.) screws and tighten.
Steps of installing module on wall:
1. If the Power Module (FPMA) or Power DC/DC 24V Module (FPDA) is installed, attach the back
covers to the casings.2. Align the holes on the first casing’s bottom with the fixing studs on the plinth.
3. Push the casing back until it stops.
4. Attach the casing to the plinth with M5 x 6 mm (0.2 in.) screws (6150188) using thread-locking
compound (medium strength, non-permanent) between 3.5-4.2 Nm (2.58-3.10 ftlb).
5. Align the holes on the second casing’s bottom with the fixing studs on the first casing.
6. Push the casing back until it stops.
7. Attach the casings to each other with M5 x 6 mm (0.2 in.) screws (6150188) using thread-
locking compound and tighten 3.5-4.2 Nm (2.58-3.10 ftlb).
8. Repeat steps 2-7 to install the remaining casings to separate plinths.
9. Slide the module into the casing.10. Attach the module(s) to the casing with M5 x 25 mm (1.0 in.) screws and tighten between 3.5-
4.2 Nm (2.58-3.10 ftlb).
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 44/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
44
For internal use only
RA22714EN01GLA04 4 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules – on wall (2/2)
13 13 13
11. Attach the fixing plates across the modulecasings on both sides of the modules and fixwith 6 screws and spring washers and tightenbetween 3.5-4.2 Nm (2.58- 3.10 ftlb).
12. Repeat steps 9-11 to install the remainingmodules.
13. Attach the cable entries to the casings withtwo M5 x 10 mm (0.2 in.) screws (6150240)and tighten between 3.5-4.2 Nm (2.58-3.10ftlb).
a) Fix the screws (do not tighten yet).
b) Attach the cable entry to the casing.
c) Tighten the screws.
11
Steps of installing module on wall: (cont’d)
11. Attach the fixing plates across the module casings on both sides of the modules and fix with 6
screws and spring washers and tighten between 3.5-4.2 Nm (2.58- 3.10 ftlb).
12. Repeat steps 9-11 to install the remaining modules.
13. Attach the cable entries to the casings with two M5 x 10 mm (0.2 in.) screws (6150240) and
tighten between 3.5-4.2 Nm (2.58-3.10 ftlb).
a) Fix the screws (do not tighten yet).
b) Attach the cable entry to the casing.
c) Tighten the screws.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 45/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
45
For internal use only
RA22714EN01GLA04 5 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules – on pole (1/2)
1. If the Power Module (FPMA) or PowerDC/DC 24V Module (FPDA) is installed,attach the back covers to the casings.
2. Align the holes on the first casing’s bottomwith the fixing studs on the plinth.
3. Push the casing back until it stops.
4. Attach the casing to the plinth with M5 x 6mm (0.2 in.) screws (6150188) using thread-locking compound and tighten.
5. Align the holes on the second casing’sbottom with the fixing studs on the firstcasing.
6. Push the casing back until it stops.
7. Attach the casings to each other with M5 x 6mm (0.2 in.) screws using thread-locking
compound and tighten8. Repeat steps 2-7 to install the remaining
casings to separate plinths.
9. Slide the module into the casing.
10. Attach the module(s) to the casing with M5 x25 mm (1.0 in.) screws and tighten.
2
3
4
5
6
7
Steps of installing module on wall:
1. If the Power Module (FPMA) or Power DC/DC 24V Module (FPDA) is installed, attach the back
covers to the casings.2. Align the holes on the first casing’s bottom with the fixing studs on the plinth.
3. Push the casing back until it stops.
4. Attach the casing to the plinth with M5 x 6 mm (0.2 in.) screws (6150188) using thread-locking
compound (medium strength, non-permanent) between 3.5-4.2 Nm (2.58-3.10 ftlb).
5. Align the holes on the second casing’s bottom with the fixing studs on the first casing.
6. Push the casing back until it stops.
7. Attach the casings to each other with M5 x 6 mm (0.2 in.) screws (6150188) using thread-
locking compound and tighten 3.5-4.2 Nm (2.58-3.10 ftlb).
8. Repeat steps 2-7 to install the remaining casings to separate plinths.
9. Slide the module into the casing.10. Attach the module(s) to the casing with M5 x 25 mm (1.0 in.) screws and tighten between 3.5-
4.2 Nm (2.58-3.10 ftlb).
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 46/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
46
For internal use only
RA22714EN01GLA04 6 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules – on wall (2/2)
11. Repeat steps 9-10 to install the remaining modules.12. Attach the cable entries to the casings with two M5 x 10 mm (0.2 in.) screws
(6150240) and tighten between 3.5-4.2 Nm (2.58-3.10 ftlb).
a) Fix the screws (do not tighten yet).
b) Attach the cable entry to the casing.
c) Tighten the screws.
12 1212
Steps of installing module on wall: (cont’d)
11. Repeat steps 9-11 to install the remaining modules.
12. Attach the cable entries to the casings with two M5 x 10 mm (0.2 in.) screws (6150240) and
tighten between 3.5-4.2 Nm (2.58-3.10 ftlb).
a) Fix the screws (do not tighten yet).
b) Attach the cable entry to the casing.
c) Tighten the screws.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 47/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
47
For internal use only
RA22714EN01GLA04 7 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules – Installing transmission sub-module
1. Align the transmission sub-module in the System Module using the slots onthe sides. Push the sub-module in place.
2. Fix the transmission sub-module with 4 x M4 screws using the TORX headscrew. Tighten at 2.7-3.3 Nm (1.99-2.43 ft-lb).
The FIQx, FIYx and FIFA sub-modules are installedthe same way as the FIPA and FIEA.
Installing FIPA/FIEA
Purpose:
The transmission sub-module is installed in the System Module (ESMB/C). The
submodule is chosen based on the transmission requirements of each site. The
transmission sub-module can be installed before or after the System Module is
installed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 48/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
48
For internal use only
RA22714EN01GLA04 8 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling Modules – Example for 1+1+1 (60 W) up to 6+6+6 (10 W)
Stack
Wall Pole
Check List
Module back covers and cable entries are installed..
Screws are tightened to the specified torque value..
For a 1+1+1 up to 6+6+6 configuration,you need the following modules:
• one System Module (ESMB/C)
• one transmission sub-module(FIxx)
• one RF Module (FXxx)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 49/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
49
For internal use only
RA22714EN01GLA04 9 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationGrounding the Modules
1. Connect the grounding cable to themodule front panel.
2. Route the grounding cable throughthe cable entry.
3. Connect the other end of the cable tothe plinth.
4. Repeat steps 1-3 with all themodules. Tighten to 3.5-4.2 Nm(2.58-3.10 ft-Ib).
Check List
Modules are grounded.
Grounding connections are tightened to the correct torque values.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 50/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 51/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
51
For internal use only
RA22714EN01GLA05 1 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – cable entry & cable clamp
1. Route the cables through cableentries.
2. Fix to cable tie points with cableties.
Caution:
Incorrect cables and seals may not provide securedenvironmental protection.Use only tested IP65 classcables with seals provided by Nokia SiemensNetworks.
Cable entry
Cable Clamp
•The strain relief of cables in stacked floor, wall or pole installation is done with
cable clamps attached on the side of the casing.
•The cables are fixed with standard cable ties, except for power supply cables.
•The fixing of power supply cables is done with special isolating cable clamps,
which come with the casing delivery.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 52/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
52
For internal use only
RA22714EN01GLA05 2 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – external power cables
1. Install the cable clamp on the side of thecasing.
2. Remove the black rubber boots, nuts,washers and cable lugs from theterminals.
3. Strip about 2 cm (.8 in) of insulation fromthe (+) and (-) DC cables.
4. Insert the stripped end of each cable into acable lug and crimp.
5. Pull each cable through a rubber boot.
6a.Connect the (-) crimped wire to the (-)connector pole, insert washer, and tightenthe nut. Connect the (+) crimped wire tothe (+) connector pole, insert washer, andtighten the nut.
6b.Torque the M10 nuts (max 14 Nm).
7. Pull the black rubber boots over the lugs.
8. Route the cable through the external cableentry.
9. Route the power cables through the cableclamp, attach and tighten the cable clampscrews with a T10 TORX screwdriver.
External power cables
12
34
5
6a
6b 7 89
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 53/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
53
For internal use only
RA22714EN01GLA05 3 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example of external power cables for 1+1+1 up to 6+6+6
External power cables in a 1+1+1up to 6+6+6 stack configuration
without (a) and with (b) EAC
(a)
(b)
External power cables in a 1+1+1 up to 6+6+6wall and pole configuration
Note:
• The allowed 48 V DC cable cross-section size for theSystem Module (ESMB/C) is 21- 35 mm2 (0.82-1.37 sq.in. or 4-2 AWG) that can be used.
• Nokia Siemens Networks recommends to locally sourcethe exact lug sizes when the DC cable thickness is 25mm2 (4 AWG or 0.98 in2) or less.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 54/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
54
For internal use only
RA22714EN01GLA05 4 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – internal power cables
1. Remove the connector seal onthe module to uncover theconnector.
2. Connect the cable to the SystemModule.
3. Push the connector seal firmly inplace.
4. Connect the other end of theinternal power cable to the RF
Module. Push the cableconnector seal firmly in place.
Internal power cables
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 55/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
55
For internal use only
RA22714EN01GLA05 5 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example of internal power cables for 1+1+1 up to 6+6+6
Internal power cables in a1+1+1 up to 6+6+6 stack
configuration
Internal power cables in a 1+1+1 upto 6+6+6 wall and pole configuration
1
Number
995281
Cable
PWR (System Module) - PWR IN (RF Module)
From-to
Connecting internal power cables for a 1+1+1 up to 6+6+6 configuration
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 56/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
56
For internal use only
RA22714EN01GLA05 6 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – antenna cabling
1. Remove the connectorseal on the module touncover the connector.
2. Remove seals from theantenna connectors.Store the connector sealsfor later use.
3. Connect the cable to theantenna connectors.
4. Route the antenna cablesthrough the cable entry.
5. Tighten the connectorwith a torque wrench setto 25 Nm.
6. Repeat the previous stepsfor all antenna cablesrequired for yourconfiguration.
Antenna cabling
1
2
3
Purpose:
Jumper cables are connected to the antenna connectors in the front panel of the RF Module (FXxx) and the other end of the jumper cables are carefully connected to the respective feeder cables. The number of cables used depends on theconfiguration.
While connecting the antenna jumper cables, consider the following guidelines:
☞ Connect the antenna cables starting from the module closest to the plinth.
☞ It is recommended to the start connecting the jumper cable from ANT (Tx/Rx) connector closest to the direction of routing.
For example, in stack installations,
– If you are routing all jumper cables to the right, then the order to be followed isANT 1, ANT 3, ANT5, ANT 2, ANT 4
and ANT 6.
– If you are routing all jumper cables to the left, then the order to be followed is ANT 5, ANT 3, ANT1, ANT 6, ANT 4 and
ANT 2.
– If you are routing 3 jumpers cable to the left and right, the order to be followed is ANT 1, ANT 2 and ANT 3 to the right
and ANT 4, ANT 5 and ANT 6 to the left of the RF Module.
☞ Antenna jumper cables can be routed out the left side, right side, or both sides. However, access to the optical and
internal power cables during maintenance and expansion is easier when all antenna jumper cables are routed to the right.☞ To avoid cabling rework, check that the unit powers on before tying down the cables.
Follow these guidelines when selecting antenna jumper cables:
• 1/2" or 3/8" jumper cables are permitted
• One end of the jumper cable must be right angle male for connection to modules (other end depends on site configuration)
• 1/2" feeder cable can be connected directly to the modules if a right angle male connectoris used. The maximum allowedfeeder cable is 1/2" with right angle connectors.
• The length should be determined based on the Flexi Multiradio BTS installation option (for example pole, wall, cabinet, 3rdparty cabinet) and the distance of the BTS from the antenna feeder line.
• Antenna jumper cables must be rated IP65.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 57/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
57
For internal use only
RA22714EN01GLA05 7 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example antenna cabling for 1+1+1 up to 6+6+6 (1/2)
Antenna jumper cables in 1+1+1 up to
6+6+6 2UD configuration with unchained
RF Modules in stack routed toward the
right
Antenna jumper cables in 1+1+1 up to
6+6+6 2UD configuration with unchainedRF Modules in stack routed toward the
left
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 58/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
58
For internal use only
RA22714EN01GLA05 8 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example antenna cabling for 1+1+1 up to 6+6+6 (2/2)
Antenna jumper cables in 1+1+1 up
to 6+6+6 2UD configuration with
unchained RF Modules in stack
routed to left and right
Antenna jumper cables in 1+1+1 up to 6+6+6
2UD wall and pole configuration
Note :
• Antenna jumper cables can be routed out the left side, right side, or both sides for stack installation
• For wall and pole installation, antenna jumber must be routed to the lower side of module
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 59/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 60/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
60
For internal use only
RA22714EN01GLA06 0 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example connecting transmission cables for 1+1+1 up to6+6+6 using FIEA, FIPA, FIQA and FIYA without optical transceiver
Transmission cables in a 1+1+1up to 6+6+6 stack configuration
Transmission cables in a 1+1+1up to 6+6+6 wall and Pole
configuration
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 61/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
61
For internal use only
RA22714EN01GLA06 1 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example connecting transmission cables for 1+1+1 up to6+6+6 using FIFA
Note that a Flexbus Jumper cablemust be used to interconnect the FIFAFlexbus interface and the Flexbuscable from the outdoor unit.
1
2 3
4
1. Route the Flexbus Jumper cable
through the cable entry and connect
the Flexbus Jumper cable to FIFA,
Flexbus 1 interface.
2. Connect the Flexbus Jumper cable to
Flexbus cable (from the outdoor
unit).
3. Add weatherproof protection tape on
the Flexbus Jumper Cable and
Outdoor Flexbus cable connection.
4. If there is Flexbus 2 in use, repeat
the steps and connect the Jumper
cable to Flexbus 2 interface.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 62/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
62
For internal use only
RA22714EN01GLA06 2 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – optical cabling (1/2)
Optical cabling
1 2
47
1. Remove connector seal from OPT1connector in ESMB/C.
2. Remove protective cap from opticaltransceiver and insert it into OPT1in ESMB/C.
3. Route optical cable through cableentry.
4. Uncover the connector. Pull backthe optical cable connector seal touncover the connector.
5. Remove protective plugs.
6. Clean connectors with 99% alcoholand swabs.
7. Connect optical cable to optical
transceiver in ESMB/C.8. ……. Cont’d
…… Cont’d8
Caution:
Overbending optical fiber cables damages the cables and can detachor damage the connectors.
Do not bend optical fiber cables to a radius smaller than the minimumradius of 70 mm (3 inches).
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 63/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
63
For internal use only
RA22714EN01GLA06 3 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – optical cabling (2/2)
Optical cabling
8
8. Push connector seal firmly.9. Repeat steps 1-8 to connect
optical transceiver and opticalcable to OPT1 of FXxx.
10.Ensure all connector seals areproperly installed.
Check List
DC power cables are connected and the cableclamp is in place.
Connector seals are firmly in place.
All cables are connected according to the
configuration. BTS external cables or cables between the
modules on different plinths are routed viacable entries.
Connector seals are firmly in place.
To avoid cabling rework, check that the unitpowers on before tying down the cables.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 64/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
64
For internal use only
RA22714EN01GLA06 4 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationCabling – example of connecting optical cables for 1+1+1 up to 6+6+6
Optical cables in 1+1+1 up to6+6+6 stack configuration
Optical cables in 1+1+1 up to6+6+6 wall and pole configuration
1
Number
994807D
Cable
OPT1 (System Module) - OPT1 (RF Module)
From-to
Connecting optical cables for a 1+1+1 up to 6+6+6 configuration
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 65/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
65
For internal use only
RA22714EN01GLA06 5 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationPowering up and commissioning the BTS
1. Power up the site and check theLEDs.
2. Commission the BTS.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 66/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
66
For internal use only
RA22714EN01GLA06 6 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling module front covers
1. Fix the maintenance strap. (Pole or wall only)
Attach the first and second snap hooks of the maintenance strap to the front cover. Attach the third snap hook of the maintenance strap to the external cable entry.
2. Place the cover on top of the module front panel.
3. Fix the screws. Tighten the screws to 2.0 - 2.5 Nm (1.5-1.8 ft-Ib)
Maintenance strap Module front covers
11
1
2
3
Check List
Module front panel covers are installed.
Purpose
Module back and front covers complete IP65 protection for core modules. Back and
front covers are required for safety reasons, in all installations including indoorinstallations.
Note:
•The front panels of the modules are hot during operation. If Flexi Multiradio BTSmodules are not installed in a cabinet, front covers must be used during operationfor safety reasons and should only be removed temporarily for maintenance.
•Rotating fan blades can cause personal injury. If Flexi Multiradio BTS modules arenot installed in a cabinet, back covers must be used during operation for safetyreasons and should only be removed temporarily for maintenance.
Before start:
☞When there is no risk of dropping the covers, safety catches are not needed.
☞ To avoid cabling rework, check that the unit powers on before tying down thecables.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 67/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
67
For internal use only
RA22714EN01GLA06 7 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstalling module back covers
3U casings comes with back covers preinstalled. Install the back coversbefore installing the modules. In case it’s not installed, here is theprocedure:
1. Attach the first and second snap hooks of the safety catch to the backcover.
2. Attach the third snap hook of the safety catch to the rear of the casing.
3. Install the back cover in the rear of the module and fix the screws (TORXT25). Tighten to 2.0 - 2.5 Nm (1.5-1.8 ft-lb).
Installing back cover
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 68/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 69/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
69
For internal use only
RA22714EN01GLA06 9 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstallation Checklist (1/4)
Delivery is complete and undamaged.
Site meets the minimum clearances.
Adapter mechanics are installed (for wall and poleinstallation)
Plinth is installed according to the instructions.
Plinth is grounded.
Transmission sub-module is installed according to theinstructions.
If power modules (FPDA or FPMA) are used, back coversare installed on them.
Modules are installed according to the instructions.
Cable entries are installed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 70/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
70
For internal use only
RA22714EN01GLA07 0 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstallation Checklist (2/4)
One module per casing is grounded to the plinth.
External power cables are connected.
Internal power cables are connected.
Optical cables are connected.
Antenna jumper cables are connected.
Transmission cables and sub-modules are connected, and
in case the FIQA/FIYA is used in the PWE mode and the
PW traffic is transmitted via Gigabit Ethernet, the optical
transceiver is installed.
Optional cables (EAC, Synchronisation, Site support
interface, FPA interface, LMP, LMU cables) are connected.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 71/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
71
For internal use only
RA22714EN01GLA07 1 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstallation Checklist (3/4)
BTS external cables or cables between the modules on
different plinths are routed via cable entries.
Cables between the modules on the same plinth are routed
via internal cable entries.
All boots and caps are properly connected and IP-sealed.
Cables used are provided by Nokia Siemens Networks
(excluding site grounding, external power and antenna
jumper cables).
Screws are tightened to the specified torque value.Note: In pole and wall installations, screws are secured with
thread locking compound.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 72/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
72
For internal use only
RA22714EN01GLA07 2 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE SWP InstallationInstallation Checklist (4/4)
Only IP65 class cables with seals provided by Nokia
Siemens Networks are used.
BTS is switched on and all units are ready.
Module front covers are installed.
Site is clean and installation completed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 73/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
73
For internal use only
RA22714EN01GLA07 3 © N ok ia Si em en s N et wo rk s
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 74/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
74
For internal use only
RA22714EN01GLA07 4 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGEInstallation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet forIndoor (FCIA) Installation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 75/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
75
For internal use only
RA22714EN01GLA07 5 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinetfor Indoor (FCIA) – General Procedure
Contents ofDelivery
Clearances
Changing thedoor opening
direction
Lifting thecabinet
Installing thecabinet
Grounding thecabinet
Installing theModules
CablingPrinciples
Routing cabinetexternal cabling
InstallingChecklist
1
2
3
4
5
6
7
8
9
10
C h e c k i n g
C a b l i n g
C h e c k -
l i s t
Start
Lifting the cabinetwith rope
Lifting the cabinet
With handles
Anchoring thecabinet
RecommendedInstallation order
Installation example
Finish
MinimumClearance
Fixing points
C a b i n e t I n s t a l l a t i o n
M o d u l e I n s t a l l a
t i o n
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 76/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
76
For internal use only
RA22714EN01GLA07 6 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationContents of Delivery
Site package 2
Site package 1
822083Guideplates (30pcs)
Version
6332594Loosecage nuts(28 pcs)
Cage nuts(62 pcs)
6490006Cabinetkey
470152AANokia FlexiCabinet forIndoor (FCIA)
ProductCode
Contentsof delivery
Delivery
Check List
Delivery is complete.
Equipment is not damaged.
1800
600600
Flexi Cabinet for Indoor (FCIA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 77/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
77
For internal use only
RA22714EN01GLA07 7 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationClearance
Minimumclearances
Fixing points
NOTE: Maintenancespace is notincluded.
Check List
Site meets the minimum clearances.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 78/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
78
For internal use only
RA22714EN01GLA07 8 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationChanging the door opening direction (1/2)
1. Remove the groundwire and hinge pins,and detach the door.
2. Loosen the hingescrews and removethe hinges.
3. Install the hinges onthe opposite side ofthe cabinet.
4. …cont’d
1 2
3
NOTE: If changing the handedness of the door is not needed, skip next step
Principle of changing the door opening direction
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 79/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
79
For internal use only
RA22714EN01GLA07 9 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationChanging the door opening direction (2/2)
4. Remove the door lock-plate.5. Install the door lock-plate on the
opposite side of the cabinet.
6. Flip the door end-to-end.
7. Mount the door on the opposite side.Reinstall the ground wire afterattaching the hinge pins.
Principle of changing the door opening direction (cont’d)
4
5
6
Check List
Door opening direction andmagnetic sensor is changed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 80/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
80
For internal use only
RA22714EN01GLA08 0 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationLifting the Cabinet
Lifting the cabinet with a rope Lifting the cabinet with WLHA handles
1. Align the handle screw holes with the fourM5 screw holes on the side of the cabinet.
2. Fix the handles to the cabinet with four M5screws provided with the kit.
3. Lift the cabinet carefully to the desiredinstallation location.
4. Remove the lifting equipment.
1. Attach the 4 x M12 lifting eye bolts to the liftingpoints.
2. Attach the hoisting belt or rope to the lifting eyebolts.
3. Lift the cabinet carefully to the desiredinstallation location.
4. Remove the lifting equipment.
1
2
1
2
Minimum500 mm(19.6 in.)
TIP: It is possible to lift the cabinet with modules installed and internal cabling completed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 81/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
81
For internal use only
RA22714EN01GLA08 1 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationInstalling the cabinet
Anchoring the cabinet 1. Mark the anchoring bolt holes withthe help of the drilling template.
2. Drill the anchoring bolts holes on thebase.
3. Attach the anchoring bolts to thebase.
4. Position the cabinet on the anchoringbolts.
5. Fix the nuts on the anchoring bolts.
6. Check that the cabinet is level.
7. Tighten the nuts properly(recommended 49.0Nm (36.1 ft-lb)).
Note that the cabinet should be attached to
the base with M10 or M12 anchor bolts, nuts,and washers (4 pcs each). The recommended
anchor bolt length is 60 mm (2.36 inches).
Anchor bolts and nuts are not provided withthe Flexi BTS delivery and must be acquired
locally.
Check List
Cabinet isanchoredaccording toinstructions.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 82/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
82
For internal use only
RA22714EN01GLA08 2 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationGrounding the cabinet (1/2)
1. Make sure the groundingcable is fixed to the sitegrounding point.
2. At the top of the cabinet,remove the screw and starwasher.
3. Strip approx. 2 cm (0.79 in.) ofthe main ground cable.
4. If this is a NEBS installation,bring the mating surfaces of allunplated ground connectionsto a bright finish, using
emerycloth -(or other suitablemethod). Then coat theexposed ground cableconductor with antioxidant.
5. ….. Cont’d
Side view of Cabinet
A
B
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 83/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
83
For internal use only
RA22714EN01GLA08 3 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationGrounding the cabinet (2/2)
1. Insert the stripped end of thecable into a cable shoe lugand crimp.
2. Fit the lug to the groundingpoint in the cabinet and fixwith a star washer and screw.
Tighten M5 to 3.5-4.2 Nm(2.58-3.10 ft-lb). Tighten M8 to8.0-10.0 Nm (5.9-7.37 ft-lb).
Top view of Cabinet
Check List
Cabinet is correctly grounded.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 84/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
84
For internal use only
RA22714EN01GLA08 4 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationInstalling Modules (1/2)
Recommended Installation Order
1 2 3
4
1. Push the front part of theguide plate in place first, andthen the back part.
2. Fix the cage nuts according tothe configuration.
3. Slide the first module in.
4. Fix the module to the cabinetwith screws.
5. Repeat for each subsequent
module.
Check List
Modules are installed according toinstructions.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 85/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
85
For internal use only
RA22714EN01GLA08 5 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationInstalling Modules (2/2)
Installation Example
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 86/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
86
For internal use only
RA22714EN01GLA08 6 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Indoor (FCIA) InstallationCabling Principles
Cabling Principles
Check List
Cables are correctly routed.
Cables are correctly connected.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 87/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 88/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
88
For internal use only
RA22714EN01GLA08 8 © N ok ia Si em en s N et wo rk s
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 89/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
89
For internal use only
RA22714EN01GLA08 9 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGEInstallation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet forOutdoor (FCOA) Installation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 90/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
90
For internal use only
RA22714EN01GLA09 0 © N ok ia Si em en s N et wo rk s
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinetfor Outdoor (FCOA) – General Procedure
Contents ofDelivery
Clearances
Changing thedoor opening
direction
Lifting thecabinet
Installing thecabinet
Grounding thecabinet
Installing theModules
CablingPrinciples
Routing cabinetexternal cabling
InstallingChecklist
1
2
3
5
6
7
8
9
10
11
C h e c k i n g
C a b l i n g
C h e c k -
l i s t
Start
Lifting the cabinetwith rope
Lifting the cabinetWith handles
Anchoring thecabinet
RecommendedInstallation order
Installation example
Finish
MinimumClearance
Fixing points
C a b i n e t I n s t a l l a t i o n
M o d u l e I n s t a l l a
t i o n
Routing the cablesthrough cabinetbottom
Routing the cablesthrough cabinet roof Removing the
roof
4
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 91/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
91
For internal use only
RA22714EN01GLA09 1 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationContents of Delivery (1/2)
00049229FCOA Cabinet QuickGuide (1 pcs)
Site package 2
822546Dummy panel (10 pcs)
6150287Screws M5x12 (2 pcs)
6150747Screws K30x24 (4 pcs)
6401026Cable clamp (2 pcs)
822133Support rail (24 pcs)
6332594Loose cage nut (12
pcs)
6497988Lock latch (1 pcs)
824774Knock-out plate (2 pcs)
Site package 1
6490006Cabinet key (1 pcs)
6332594Cage nuts (56 pcs)
104
Ver-sion
Cont’d….
822990 Air Guide plate (2 pcs)
00044699Drilling template
470142AFCOAFlexi OD Cabinet
ProductCode
Contents ofdelivery
Delivery
Check List
Delivery is complete.
Equipment is not damaged.
Flexi Cabinet for Outdoor (FCOA)
1550
770770
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 92/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
92
For internal use only
RA22714EN01GLA09 2 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationContents of Delivery (2/2)
CS71362114 batteries with accessoriesPowersafe battery 48V, 62 Ah
CS71362.034 batteries with accessoriesPowersafe battery 48V, 92 Ah
466289ALEKALifting eye bolts (4 pcs)Lifting eye bolts kit
469554AWLHALifting handles (2 pcs)Lifting handle kit
471020AFMBABattery kit
469956AWPMCWideband Power Unit
469955AWPUCPower Distribution UnitMIBBU delivery (Power-One)
469950AWPMBWideband Power Unit
471424AFSEBFlexi System External AlarmExternal alarm delivery
470144AFCDAFlexi Cabinet Fire Detector Fire detector delivery
Customer specific lock + key
469784AWPUBPower Distribution UnitMIBBU delivery (Eltek)
470145AFCSAFlexi Cabinet Site Support ModuleSite support delivery
CS7000000FPRAFlexi Power Rectifier Flexi Power Rectifier delivery
FCFA
Version
470146AFlexi Cabinet Air filter Air filter delivery
Optional items
….cont’d
ProductCode
Contents of deliveryDelivery
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 93/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
93
For internal use only
RA22714EN01GLA09 3 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationClearance
Minimumclearances Fixing points
Check List
Site meets the minimum clearances.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 94/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
94
For internal use only
RA22714EN01GLA09 4 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationChanging the door opening direction (1/2)
1
23
NOTE: If changing thehandedness of the door is notneeded, skip next step
Principle of changing the door opening direction
1. Detach the windstopper from the doorand cabinet.
2. Detach the groundingcable from the door.
3. Remove the hingepins and detach thedoor.
4. Remove the hingescrews and hingesfrom the cabinet
5. .…cont’d
4 Check List
Door opening direction andmagnetic sensor is changed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 95/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
95
For internal use only
RA22714EN01GLA09 5 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationChanging the door opening direction (2/2)
5. Remove the door lock-plate.
6. Move the hinges to the new location in the cabinet.
7. Flip the door upside down and install it to the cabinet using the hinge pins.
8. Thread the wind stopper to the guiding slot in the cabinet and then attach it to the door.
9. Detach the grounding cable from the cabinet and attach it to the new location.
10. Attach the grounding cable to the door.
11. Move the magnetic proximity sensor magnet part from the bottom of the door to thetop.
Principle of changing the door opening direction (cont’d)
5
6
6
78
79
10
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 96/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
96
For internal use only
RA22714EN01GLA09 6 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationRemoving the Roof
1. Open the cabinet door.
2. Pull the roof forward.
3. Lift the roof up keeping it level.
TIP: It is possible to lift the cabinet with modules installed and internal cabling completed.
1
2
3
NOTE: You do not need to loosen or removeany screws when removing the roof.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 97/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
97
For internal use only
RA22714EN01GLA09 7 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationLifting the Cabinet
Lifting the cabinet with a rope Lifting the cabinet with WLHA handles
1. Attach the lifting handles with four screwseach.
2. Lift the cabinet to the desired location.
3. Remove the lifting handles..
1. Attach the 4 x M12 lifting eye bolts to the liftingpoints.
2. Attach the hoisting belt or rope to the lifting eyebolts.
3. Lift the cabinet carefully to the desiredinstallation location.
4. Remove the lifting equipment.
1
2
TIP: It is possible to lift the cabinet with modules installed and internal cabling completed.
3
WARNING: The cabinet is heavy. Additional personnelor lifting equipment may be needed when the cabinet ismoved, unpacked, or lined up. In addition, follow anylocal regulations applicable to the installation.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 98/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
98
For internal use only
RA22714EN01GLA09 8 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationInstalling the cabinet
Anchoring the cabinet 1. Mark the anchoring bolt holeswith the help of the drillingtemplate.
2. Drill the anchoring bolts holeson the base.
3. Attach the anchoring bolts tothe base.
4. Position the cabinet on theanchoring bolts.
5. Fix the nuts on the anchoringbolts.
6. Check that the cabinet is level.
7. Tighten the nuts properl(recommended 50Nm (36.87 ft-Ib)).
8. Make sure that any water willrun off the installation location.
Check List
Cabinet is anchored according toinstructions.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 99/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
99
For internal use only
RA22714EN01GLA09 9 © N ok ia Si em en s N et wo rk s
Flexi Cabinet for Outdoor (FCOA) InstallationGrounding the cabinet
1. Make sure the groundingcable is fixed to the sitegrounding point.
2. Guide the cable through thecable entry (see section 10)
3. Strip approx. 2 cm (0.79 in.) ofthe main ground cable.
4. Insert the stripped end of thecable into a cable shoe lug fortwo M5 thread bolts or a M8thread bolt and crimp.
5. Fit the lug to the groundingpoint in the cabinet and fixwith a star washer and nut.
Grounding Points
Check List
Cabinet is correctly grounded.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 100/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
100
For internal use only
RA22714EN01GLA0100 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationInstalling Modules (1/2)
1
1. Remove the fixing studs from themodule casings.
2. Remove the cable support plates andtheir fixing screws from the casings.
3. Loosen the module core fixing screws.
4. Detach the cage nuts and supportplates behind them from the module.
Caution: Make sure that the modulecore does not slip out of the casing.
1. Fix the guide plates (from the sitepack).
2. If the cage nuts are not in their correctlocations by default, move them as
required by your configuration.3. Remove the unnecessary preinstalled
cage nuts, if applicable.
4. Slide the module into the cabinet.
5. Fix the module to the cabinet with corefixing screws.
6. Repeat for each subsequent module.
7. Install dummy panels into the emptyslots.
Installing the Flexi Multiradio, LTE or WCDMA modulesRecommended installation order
2
2
3 3 45
6
9
8
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 101/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
101
For internal use only
RA22714EN01GLA0101 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationInstalling Modules (2/2)
Installation example,
starting from thebottom
Installing the Flexi Multiradio, LTE or WCDMA modules … cont’d
NOTE: The appearance of the modulesmay vary depending on the product ormodule type.
NOTE: Dummy panels are needed toensure proper cabinet cooling.
Check List
Modules are installed according toinstructions.
Dummy panels are installed according toinstructions.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 102/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 103/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
103
For internal use only
RA22714EN01GLA0103 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationInstalling Modules (2/2)
Installation example,
starting from thebottom
Installing the Flexi EDGE modules … cont’d
NOTE:
• The appearance of the modules may vary depending onthe product or module type.
• Dummy panels are needed to ensure proper cabinetcooling.
• If the air guide plate in the vertical rack is not required forthe configuration, it should be removed.
• The air separator plate is required if the System Moduleor the System Extension Module are installed in the
vertical left rack. Otherwise, use dummy panels in theempty slots.
Check List
Modules are installed according toinstructions.
Dummy panels are installed according toinstructions.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 104/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 105/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
105
For internal use only
RA22714EN01GLA0105 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationCabling Principles (2/2)
Check List Cables are correctly routed.
Cables are correctly connected.
Flexi EDGE cabling principles
Routing cables through
the bottom cable entry
Routing cables through the topcable entry
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 106/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
106
For internal use only
RA22714EN01GLA0106 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationRouting cabinet external cabling (1/4)
Routing the cables through cabinet bottom 1. Remove 2 pcs of right hand sideM5x12 cable entry fixing screws(6150287) and take the wholepanel, including the cable entries,out of the cabinet.
2. Remove the left and right M5x6fixing screws (6150188) andremove the entry block. If onlyone entry block is needed leavethe other one fixed in place.
3. Route the cables through thebottom and entry box front hole.Do not fix the cables outside ofthe cabinet.
TIP: For easier installation, do not fixcables outside the cabinet.
This allows cables to be moved freely.4. Route the cables through the
opening on the sheet metal panel.
5. Remove the blocking plugs fromthe entry block. Pull the plugs toremove them from the block.
Keep the plugs fore later use.
1
2
3 4
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 107/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
107
For internal use only
RA22714EN01GLA0107 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationRouting cabinet external cabling (2/4)
Routing the cables through cabinet bottom …cont’d6. If necessary, cut the rubber
sealing the hole according to yourcable thickness.
7. Organize the cables to the topand bottom row and place theentry block center piece inbetween the rows. Fix the centerpiece with left and right screws.
8. Place the cables to correct slotsand install the top and bottomrubber strips. Block any unusedholes with plugs.
9. Push back the whole assembly tothe entry box. First position it bythe left hook,then fix it with right-hand side entry screws.
10. Route the cables to the rightpositions inside the cabinet.Suitable free length can beadjusted by sliding the cablethrough the entry hole.
11. Fix the cables outside of thecabinet.
NOTE: Cable conduit can be routed through the topor bottom of the cabinet using the knock-out plates
provided in the site bag. There are three knock-outholes on the back side of the bottom cable entrybox.
Check List
Cables are routed correctly.
79
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 108/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
108
For internal use only
RA22714EN01GLA0108 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationRouting cabinet external cabling (3/4)
Routing the cables through cabinet roof 1. Detach 2 pcs M5x12 screws
(6150287) from the bottom ofthe cabinet.
2. Detach the cable entry covertogether with the cableentries from the bottom of thecabinet.
3. Remove 4 pcs M5x6 screws(6150188) from the bottom ofthe cabinet.
4. Detach the two cable entriesfrom the bottom of thecabinet.
5. Detach the roof (see section
4 Removing the roof forinstructions).
6. Detach 4 pcs M5x6 screws(6150188) from the left-handside of the inner roof.
7. Remove the two side dummypanels.
2
13
5
6
7
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 109/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
109
For internal use only
RA22714EN01GLA0109 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationRouting cabinet external cabling (4/4)
Routing the cables through cabinet bottom …cont’d6. Fix the upper cables to cable tie rails
with cable ties (if needed, cable tierails can be moved to the right orback side of the roof).
7. Install the two cable entries with 4pcs M5x6 screws (6150188). Seesteps 5 and 6 in section 10
8. Routing cabinet external cabling formore detailed instructions.
9. Fix the upper and lower cablesthrough the cable entries. See steps7 and 8 in section 10
10. Routing cabinet external cabling formore detailed instructions.
11. Reinstall the roof.
12. Install two dummy panels with 4 pcsM5x6 screws (6150188) to thebottom of the cabinet.
Check List
Cables are routed correctly
Cable entries are fixed.
The roof is installed and door closedonce the cabling is completed..
NOTE:
• The rubber cable entries are pre-installed at the bottom of thecabinet. If cable routing throughthe roof is preferred, the entries
need to be moved from thebottom to the roof.
• The cable tie rails come pre-installed. They can be moved andreinstalled on the left, right orback as desired.
• The cable entry blocks can bemoved to the back or oppositeside of the cabinet.
8
9 10
12
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 110/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
110
For internal use only
RA22714EN01GLA0110 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationInstallation Checklist (1/2)
Delivery is complete and undamaged.
Cabinet is anchored according to instructions.
Cabinet is grounded.
Modules are installed according to instructions.
External power feed cable is connected.
External antenna feeder cables are connected.
External transmission cables are connected.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 111/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
111
For internal use only
RA22714EN01GLA0111 © Nokia S iemens Ne tworks
Flexi Cabinet for Outdoor (FCOA) InstallationInstallation Checklist (2/2)
Cables are routed, connected and tied correctly.
All cable rubber seals are firmly in place.
Cables are routed downwards from modules.
Empty slots are covered with dummy plates.
Cabinet roof is installed.
Cabinet door is closed and locked.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 112/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
112
For internal use only
RA22714EN01GLA0112 © Nokia S iemens Ne tworks
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 113/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
113
For internal use only
RA22714EN01GLA0113 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 114/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
114
For internal use only
RA22714EN01GLA0114 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionOverview (1/2)
• In a feederless BTS site, RFModule can be installed at adistance from the SystemModule.
• Since Flexi Multiradio BTS hascompatible optical OBSAIinterfaces in the System Modulesand separate optical convertersare not required.
• Flexi Multiradio feederless sitesupports:
• 1UD, IDD with 2UD, IDDwith 4UD with RF Moduleconfigurations
• 15, 30, 60W Tx power levelwith RF Module
• A maximum of 3 RF Modulesfor a remote island
• 1 shared RF Module and with a maximum distance of 200 m• EDGE license optimization• Dual band with any TRXs belonging to any band, but only 2 bands together • A maximum of 6 sectors• Where the distance is less than or equal to 20 Km and a maximum of 3 RF
Modules
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 115/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
115
For internal use only
RA22714EN01GLA0115 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionOverview (2/2)
• For the optical cable connection can use:
• with multimode fiber cables can be up to 200 meters long
• with a single mode fiber can up to 40 km.
– The longer cables are not delivered in fixed length but are made on the field basedon the required length.
– Characteristics of the optical OBSAI interface can be adapted to needs with the useof standard optical transceivers
• For the power supply distribution concept, can be fed to RF Module :
• Through the System Module
– The 48 VDC power distribution cable can run up to 100 m for the RF module
– In this case, the System Module and the RF Module require separate over voltageprotection devices (FSEC).
• Using a remote power supply with AC or DC. – The RF module has external alarm interfaces for the power supply and other generic
alarms.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 116/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 117/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
117
For internal use only
RA22714EN01GLA0117 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstallation principle with AC power supply
SystemModule
OVP(FSEC)
RF Module
Power
Module(48VDC Out)
PowerSupply230V AC
(48VDC Input)
OVP(FSEC)
Optical fiber
48 VDC
Length < 2m
48 VDC
Length < 2m
Shielded cableLength < 100m
Cable shiled isgrounded via
OVP box
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 118/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
118
For internal use only
RA22714EN01GLA0118 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstallation principle with DC power supply
SystemModule
OVP(FSEC)
RF Module
PowerSupply48VDC
(48VDC Input)
OVP(FSEC)
Optical fiber
48 VDC
Length < 2m
48 VDC
Length < 2m
Shielded cableLength < 100m
Cable shiled isgrounded via
OVP box
(48VDC Output)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 119/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
119
For internal use only
RA22714EN01GLA0119 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionContents of the optical cable deliveries
Multimode LC to LC fibre LSZH version*471852AFSFQ Flexi System FibreQ HF 50m
Multimode LC to LC fibre471712AFSFP Flexi System FibreP 200m
Multimode LC to LC fibre471743AFSFD Flexi System FibreD 4m
Multimode LC to LC fibre LSZH version*471851AFSFO Flexi System FibreO HF 2m
Multimode LC to LC fibre471709AFSFH Flexi System FibreH 30m
Multimode LC to LC fibre471708AFSFG Flexi System FibreG 20m
Multimode LC to LC fibre471707AFSFF Flexi System FibreF10m
Multimode LC to LC fibre471710AFSFI Flexi System FibreI 40m
470311A
471711A
471396A
471395A
Productcode
Singlemode LC to LC fibreFTCH Single Mode 1310 LC1310 15m
Multimode LC to LC fibreFSFK Flexi System FibreK 75m
Multimode LC to LC fibreFSFC Flexi System FibreC100m
Multimode LC to LC fibreFSFB Flexi System FibreB 50m
DescriptionCable type
* LSZH = Low Smoke Zero Halogen
Contents of the optical cable deliveries
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 120/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
120
For internal use only
RA22714EN01GLA0120 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling Flexi System External OVP (FSEC) - Overview
• The Flexi System External OVP (FSEC) assembly protects the Flexi MultiradioBTS modules against surge pulses in power feeding lines.
• There are three versions of the FSEC, which are separated from each other by thefirst two digits of the factory code:
– 6Yxxxxxxxxx
– E4xxxxxxxxx
– S1xxxxxxxxxSystemModule
RFModule
RFModule
RFModule
FSEC
FSEC
FSEC
FSEC
FSEC
FSEC
From Powerdistribution ports
• There are two mountingkits for the FSEC:
– Flexi Mounting Auxiliary Brackets(FMAA) for stack
installations – Flexi Pole Installation
Kit (FPIA) for poleand wall installations
installation example with threeRF Modules
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 121/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
121
For internal use only
RA22714EN01GLA0121 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation position (1/3)
• If using Flexi Mounting Auxiliary Brackets (FMAA), see the followingfigures for the installation position of the FSEC on the module casing.
FMAA with FSEC
FMAA with two FSECs
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 122/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
122
For internal use only
RA22714EN01GLA0122 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation position (2/3)
• If using Flexi Mounting Auxiliary Brackets (FMAA), see the followingfigures for the installation position of the FSEC on the module casing.
FMAA with FSEB and FSEC
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 123/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 124/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
124
For internal use only
RA22714EN01GLA0124 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation Procedure (1/5)
1. Open the lid of the FSEC box.
If you have version S1xxxxxxxxx,
remove the protector board from insidethe FSEC at this point to make
connecting the wires easier.
2. Install the box.
The maximum installation distance of
the FSEC is 1.5 m (59.1 in) from the RF
Module.
2. Cont’d ……In pole
installations, use the
fixing kit:
a) Thread the strainingstraps to theinstallation plate.
b) Tighten the strainingstraps around the
pole.
1
2a 2b
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 125/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
125
For internal use only
RA22714EN01GLA0125 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation Procedure (2/5)
3. Connect the grounding
cable (GND).
Route the grounding cable from
the bottom right corner of the
FSEC box to the grounding
point on the plinth.4. Cut the DC cable included
in the delivery close to the
connector, strip it as
necessary to reveal the
black and blue wires and
connect the wires
3
4 4
4
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 126/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
126
For internal use only
RA22714EN01GLA0126 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation Procedure (3/5)
5. Connect the other end of the DC cable
to the RF Module.
Make sure that the seal cap is in place.
6. Connect the DC feeder cable to the
FSEC box as shown in the figures.
Connecting DC cableto Dual RF Module
Connecting DC feedercable to FSEC(6Yxxxxxxxxx)
48V system floating or 48V system positive grounding
+24V/48V system, negative grounding
5
6
6 6
66
Note:
• The colours of the cables may vary depending on the country or cable type.
• The shielding of the feeder cable must be connected to the PE terminal at both
ends.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 127/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
127
For internal use only
RA22714EN01GLA0127 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation Procedure (4/5)
7. Route the DC cable to the System Module.
8. If S1xxxxxxxxx is used, reinstall the protector board.
9. Install the module front covers.
7
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 128/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
128
For internal use only
RA22714EN01GLA0128 © Nokia S iemens Ne tworks
Flexi Multiradio BTS Feederless SolutionInstalling FSEC - Installation Procedure (5/5)
7. If used, connect the alarm
cable (not included in the
FSEC delivery).
8. Repeat steps 4-7 for
connecting the FSEC to the
System Module.
9. Check the FSEC
connections and close the
box.
10
12
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 129/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
129
For internal use only
RA22714EN01GLA0129 © Nokia S iemens Ne tworks
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 130/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
130
For internal use only
RA22714EN01GLA0130 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Installing Optional Items/modules:
• Installing Flexi System External Alarm (FSEB)
• Installing Flexi Power Module (FPMA)
• Installing Flexi Power Rectifier (FPRA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 131/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
131
For internal use only
RA22714EN01GLA0131 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Installing Optional Items/modules:
• Installing Flexi System External Alarm (FSEB)
• Installing Flexi Power Module (FPMA)
• Installing Flexi Power DC/DC Module 24V (FPDA)• Installing Flexi Power Rectifier (FPRA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 132/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
132
For internal use only
RA22714EN01GLA0132 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Overview
• The optional Flexi System External Alarm Module (FSEB) is used when up to24 external alarm inputs and 6 control outputs need to be supported with FlexiMultiradio BTS.
• The FSEB can be installed in the following ways:
– On a wall (vertical or horizontal position)
– On a module casing in pole, wall, or stack installations using Flexi Mounting AuxiliaryBrackets (FMAA).
– In the FCIA or FCOA roof (horizontal position only)
– In Citytalk cabinets, the FSEB can be installed on top of the stack (depending onworking space) or outside of the cabinet. The box cannot be installed on the roof.
• The module also supports Flexi Cabinet Fire Detector (FCDA).
• If there is not enough space left for the FSEB or other auxiliary boxes on the FCIA,
FCOA, or the FMAA, the additional auxiliary box(es) must be installed on a wall orpole close to the BTS.
• In stack, wall or pole installations, additional FMAA brackets can also be installed ifthere are multiple plinths. Note that the distance from each box to the BTS islimited by the lengths of the cables coming from the auxiliary box.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 133/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
133
For internal use only
RA22714EN01GLA0133 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Installation Position (1/3)
FMAA with FSEB
FMAA with FSEB and FSEC
installation position of the FSEB
on the module casing.
Before installing the FSEB, see FSEB interface signals and connector pin
assignments.
In pole or wall installations, locate the box in the proximity of the System Module. Inwall
installations, make sure that the mounting surface is flat. The distance from the
FSEB
to the System Module is limited by the length of the alarm cable.
If using Flexi Mounting Auxiliary Brackets (FMAA), see the following figures for the
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 134/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
134
For internal use only
RA22714EN01GLA0134 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Installation Position (2/3)
FSEB fixing points on the FCOA roof
In FCIA and FCOA installations, use the fixing points on the cabinet roof.
FSEB fixing points on the FCIA roof
Summary
The FSEB can be installed either horizontally (cable lead-ins on the side) or
vertically (cable lead-ins facing downwards, or left or right). See the following figuresfor the two installation options.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 135/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
135
For internal use only
RA22714EN01GLA0135 © Nokia S iemens Ne tworks
Note : In outdoor installations, the cable lead-ins mustbe facing downwards, left or right to meet the IP65standard.
Installing Flexi System External Alarm (FSEB)Installation Position (3/3)
FSEB installed horizontally
FSEB installed vertically
FSEB connectors
Fixing FSEB cables
When the cable is routed down, tie the cable a maximum of500 mm (19.7 in.) away from the FSEB to prevent theweight of the cable to break the cable lead glands of theFSEB.
• When connecting the cables, make sure that the cable lead-ins that are not used
are blocked.
• A module ground cable is not included in the FSEB delivery. The minimum cross-section of the cable should be 2.5 mm2 (14 AWG). The length of the cable
should be determined based on the FSEB installation option (for example pole,
wall, cabinet, 3rd party cabinet)
Summary
• The FSEB can be installed either horizontally (cable lead-ins on the side) or
vertically (cable lead-ins facing downwards, or left or right). See the following
figures for the two installation options.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 136/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
136
For internal use only
RA22714EN01GLA0136 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Installation procedure (1/3)
1. Install FSEB with four M5 screws using the fixing holes
in the bottom of the box.
2. Ground the box using the grounding screw on the right
side of the FSEB front plate.
3. Connect the ESD wrist strap first to your wrist and then
to the grounding clip next to the grounding screw.
4. Open the lid of the FSEB box.
5. Connect the external alarms cable (included in the
FSEB delivery) from the FSEB to the System Module.
See the notes page for detail.
1
2
3
5a5b
5c
5d
5e 5g
5f 5i
Steps:
1. Install FSEB with four M5 screws using the fixing holes in the bottom of the box.
2. Ground the box using the grounding screw on the right side of the FSEB front plate.
3. Connect the ESD wrist strap first to your wrist and then to the grounding clip next to the grounding screw.
4. Open the lid of the FSEB box.
5. Connect the external alarms cable (included in the FSEB delivery) from the FSEB to the System Module.
a) Pull the left U-shaped cable gland from the FSEB box.
b) Remove the hole closing plug from the cable gland. If the plug is fixed with a cable tie, cut the cabletie first and remove it.
c) Insert the cable in the cable gland. The D-Sub plug must point to the inside of the box.
d) Connect the D-Sub plug to the leftmost D-Sub connector X1101 (ESM) on the FSEB board.
e) Fix the connector fixing screws.
f) Insert the U-shaped cable gland to the front plate.
g) Insert the cable to the round rubber-seal in front of the U-shaped cable gland.
h) Fix the cable with a cable tie. Make sure that the U-gland fixes the cable tightly. The cable must notmove inside the gland.
i) Route the cable between the FSEB and System Module and fix it with cable ties. The first fixing pointmust not be further away from the FSEB box than 0.5 m (1.6 ft).
j) Remove the cover of the EAC connector on the System Module.
k) Insert the other end of the cable with the MDR-36 connector to the EAC connector of the SystemModule. Make sure that the MDR connector is firmly in place.
l) Push the connector cover over the MDR connector and seal the EAC connector at the SystemModule with this cover.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 137/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
137
For internal use only
RA22714EN01GLA0137 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Installation procedure (2/3)
6. If you are using an existing
alarm cable (cable
diameter min. 4-6 mm,
ovality 1 mm) with a 37-
pole D-Sub connector,
connect the cable with a D-
Sub connector.
7. If you are using the
separate alarm cables,
connect them to the screw
terminals
8. If you are using the control
output cables, connectthem as figure:
6. If you are using an existing alarm cable (cable diameter min. 4-6 mm, ovality 1 mm) with a
37-pole D-Sub connector, connect the cable with a D-Sub connector as follows:
☞
These two alarm cables can be connected to the EACX-I and EACX-II connectors of the FSEB,respectively. Connect the Flexi Multiradio BTS alarm cables (CS73113.01) 1-12 and 13-24 to
EACX-I and EACX-II connectors. Pay attention to connect them to the right EACX connector,
otherwise the alarm number and alarm description will not match. After the installation, trigger and
verify the alarm condition using the 2G Flexi BTS Site Manager.
a) Pull the right U-shaped cable gland from the FSEB box.
b) Cut the cable tie off the cable gland.
c) Remove the hole closing plug from the cable gland.
d) Insert the alarm cable in the cable gland. The D-Sub plug must point to the inside of the
box.
e) Attach the D-Sub plug to the right 37-pole D-Sub connector X4101 (EACX-I port).
f) Fix the connector fixing screws.
g) Insert the U-shape cable gland to the front plate.
h) Insert the cable to the round rubber-seal in front of the U-shaped cable gland.
i) Fix the cable with a cable tie. Make sure that the U-gland fixes the cable tightly. The cable
must not move inside the gland.
j) Route the cable and fix it with cable ties. The first fixing point must not be further away
from the FSEB box than 0.5 m (1.6 ft).
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 138/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
138
7. If you are using the separate alarm cables, connect them to the screw terminals as
follows:
a) Tighten the cable gland nut. The cable must not move inside the gland.b) Insert the alarm cables in the FSEB box by using the cable glands on the right-side half
of the FSEB box.
c) Route the alarm cables and fix them with cable ties. The first fixing point must not be
further away from the FSEB box than 0.5 m (1.6 ft).
d) Attach alarm lines EXT_AL1 to EXT_AL12 using screw terminal blocks X4106-X4109.
e) For each alarm input, connect one wire to the GROUND screw terminal blocks X4107 or
X4109 and connect one wire to the selected alarm input on screw terminal blocks X4106
or X4108. The alarm inputs are marked on the FSEB board with 'EXT_AL6 ... EXT_AL1'
on X4106 and 'EXT_AL12 ... EXT_AL7' on X4108.
☞ If you use alarm inputs on the EACX-I port (D-Sub connector X4101), do not use the
same alarm inputs on the screw terminals X4106 and X4108.
8. If you are using the control output cables, connect them as follows:
a) Tighten the cable gland nut. The cable must not move inside the gland.
b) Insert the control output cables in the FSEB box by using the cable glands on the right-
side half of the box.
c) Route the control cables and fix them with cable ties. The first fixing point must not be
further away from the FSEB box than 0.5 m (1.6 ft).
d) Attach the control lines EXT_CO1 to EXT_CO6 by using the screw terminal blocks
X4104 and X4105.
e) Control outputs are open collector type. Connect a pull-up resistor (2-6 kilohms, 5
kilohms is recommended) or an opto-coupler to +5 V to ensure correct operation. The
control outputs are marked on the FSEB board with 'EXT_CO6 ... EXT_CO1‘ on X4104.
If galvanic isolation is required for the customer application, see the figure above for an example
with an opto-coupler. Follow the country-specific safety requirements.
The transistors and the serial resistors on their collectors are located in the System Module (not
in FSEB).
☞ If you use control outputs on the EACX-I port (D-Sub connector X4101), do not use the same
control outputs on the screw terminal X4104.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 139/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
139
For internal use only
RA22714EN01GLA0139 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Installation Procedure (3/3)
9. Install the fire detector to the FSEB (optional).
10. Install the cover of the FSEB box and tighten the eight screws to 1.7 Nm.
Install the cover
10
9. Install the fire detector to the FSEB (optional):
a) Connect the fire detector to the FSEB using a four-wire cable. Two wires are needed for
fire detector power supply and two for the fire detector alarm connection.
b) Attach the four wires of the cable to the fire detector relay-base.
c) Insert the other end of the four wire cable through one cable gland at the right half of the
FSEB box. Tighten the cable gland nut.
d) The cable must not move inside the gland.
e) Route the cable and fix it with cable ties. The first fixing point must not be further away
from the FSEB box than 0.5 m (1.6 ft).
f) Attach the wire marked with + from the fire detector to the leftmost or rightmost opening
of the screw terminal X4114.
g) Attach the wire marked with - from the fire detector to one of the four middleopenings of
the screw terminal X4114 marked with GND.
h) Attach the fire detector alarm wires to one of the alarm inputs 'EXT_AL12 ... EXT_AL1'.
10. Install the cover of the FSEB box and tighten the eight screws to 1.7 Nm.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 140/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
140
For internal use only
RA22714EN01GLA0140 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Connecting external alarms cable
• There are two options for external alarm cables in Flexi BTS:
– Flexi System External Alarm Module (FSEB) external alarm cable
– Flexi System Alarm cable (FSAA)
• The FSEB external alarm cable is connected from the System Module to theFSEB.
• The FSAA cable connects from the System Module directly to UltraSite,ExtraTalk, or other alarm systems.
• The FSAA cable is used when an FSEB is not required.
• The FSAA cable is used when an FSEB isnot required.
• The FSAA cable connects directly toUltraSite and ExtraTalk alarm cables withthe Dconnector.
• The FSAA cable can be connected to otheralarm systems by cutting the Dconnector and connecting the wires to the terminals.
Steps:
1. Remove the connector seal from the external alarms connector in the System Module
front panel. Store the seal for later use. The seal can be stored in the plinth.
2. Route the external alarms cable through the cable entry (stack, wall and pole
installations).
3. Pull back the connector seal covering the external alarms cable connector.
4. Connect the cable to the external alarms connector.
5. Push the cable connector seal firmly in place.
6. Route and connect the other end of the external alarms cable to the external alarms
control box or to the distribution frame. If connecting to an FSEB, connect the other end of
the cable to the ESM connector in the FSEB. If connecting to an UltraSite or ExtraTalk alarm
cable, connect the other end to the cable.
7. Make sure that all connector seals are firmly in place.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 141/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
141
For internal use only
RA22714EN01GLA0141 © Nokia S iemens Ne tworks
Installing Flexi System External Alarm (FSEB)Installing optional Flexi Mounting Auxiliary Brackets
(FMAA)• The FMAA can be used with the following auxiliary units:• Flexi System External Alarm (FSEB)
• Flexi System External OVP (FSEC)
• Location Measurement Unit (LMUB) Outdoor
1. Remove the four connection pins
from the casing on which the
FMAA will be installed.
2. Align the outer holes of each
bracket with the connection pin
holes.
3. Use the M5 X 6 screws to mount
each bracket to the casing.
4. Mount the auxiliary unit on the
brackets
1
3
44
3
Before you start
Make sure the mains breaker is off. For FPMA installation locations in Flexi
Multiradio BTS configurations..
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 142/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
142
For internal use only
RA22714EN01GLA0142 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Installing Optional Items/modules:
• Installing Flexi System External Alarm (FSEB)
• Installing Flexi Power Module (FPMA)
• Installing Flexi Power DC/DC Module 24V (FPDA)
• Installing Flexi Power Rectifier (FPRA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 143/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
143
For internal use only
RA22714EN01GLA0143 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole (1/3)
• The Flexi Multiradio BTS uses 48 VDC power.
• In a BTS site with AC feed only, a Flexi Power Module (FPMA) isrequired for converting the AC to DC before feeding the DC power to theSystem Module.
• The Flexi Power Module (FPMA) consist of :
• Mechanics
• AC terminal
• and four slots for AC/DC sub-module (FPAA) or battery sub-module(FPBA)
AC input cabling
to FPMA
+
-
48VDC
output to
BTS
AC feed to
FPAA (3pcs)
Example of FPMA with3 AC/DC sub-modulesand 1 Flexi Power
Battery
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 144/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
144
For internal use only
RA22714EN01GLA0144 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole (2/3)
• The following FPMA and FPAA/FPBA combinations are allowed:
• Up to two FPMAs can be connected to one System Module
• If two FPMAs are connected to the same System Module, doublerubber boots (822862) are required for safety
• Any combination of up to four FPAAs and FPBAs can be installed inone FPMA
• To find the number of FPAAs required for a configuration, see thesection Common cabinet configurations in the documents CreatingStack, Wall and Pole Configurations for Flexi Multiradio BTSGSM/EDGE . See also Creating FCIA configurations for Flexi MultiradioGSM/EDGE BTS and Creating FCOA configurations for Flexi
Multiradio GSM/EDGE BTS.• If two FPMAs are connected to the same System Module and both
FPMAs contain FPBAs, the current draw is distributed evenly amongall FPBAs.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 145/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
145
For internal use only
RA22714EN01GLA0145 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole (3/3)
• The FPMA must be located close enough to the System Module so that the alarm cableand DC power cables reach the appropriate connectors without blocking access to othermodules.
• In stack, wall, and pole installations, the recommended location for the FPMA is below theSystem Module on the same plinth.
• By default, the DC output voltageof the FPMA is floating nominal48 VDC, however, it can also bepositive grounded as in the figure.
• The maximum diameter of the ACpower feed cable is 24 mm (0.9in.)
up to 10 mm2 (7 AWG)Flexible with ferrule (with plastic sleeve)
up to 6 mm2 (9 AWG)Flexible with TWIN ferrule
up to 10 mm2 (7 AWG)Flexible with ferrule (without plastic sleeve)
up to 10 mm2 (7 AWG)Flexible
up to 16 mm2 (6 AWG)Rigid (solid or stranded)
ValueRated connecting capacity
Maximum sizes of conductors
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 146/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
146
For internal use only
RA22714EN01GLA0146 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole – Installation Procedure (1/5)
1. Install the Flexi Power Module (FPMA) andground it.
2. Loosen the two top screws and detach thebottom screw.
3. Remove the ingress protection plate fromthe left-hand side of the FPMA.
4. Pull out the AC terminal plate.
5. Route the cable through the round hole inthe top left corner of the ingress protectionplate.
6. Route the cable through the cable clampon the AC terminal plate.
1
2
3
6
5
Before you start
• Check that the mains breaker is off.
• For FPMA installation locations in Flexi Multiradio BTS configurations, see
Optional power modules (FPDA and FPMA) in Flexi Multiradio BTS configurations.
Steps:
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 147/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
147
For internal use only
RA22714EN01GLA0147 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole – Installation Procedure (2/5)
7. Make the AC connection
See the figures for AC connection alternatives
Note: Danger of lethal voltages! Switch offthe AC power breaker before connectingthe AC cable.
Single phase AC connection, 230 VAC
Split Phase L1-L2 base voltage 100-120 V AC
3-phase star connection, 230 V AC
3-phase delta connection, basevoltage 100-120 V AC
NOTE:REMOVE BRIDGES
NOTE:REMOVE BRIDGES
Note: The colours of the wires may vary depending onthe country.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 148/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
148
For internal use only
RA22714EN01GLA0148 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole – Installation Procedure (3/5)
8. Push the AC terminal plate halfway back
into its slot.
9. Install the FPAA sub-modules required
by your configuration.
The first or only FPAA must always be installed
in the leftmost module slot. If there are empty
slots, they must always be on the right.
8. Fix the FPAA screws.
9. Connect the AC cable from the FPAA to
the FPMA AC terminal plate.
10. If you are using battery backup, installthe FPBA sub-modules required by your
configuration.
8 9
10
11
12
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 149/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
149
For internal use only
RA22714EN01GLA0149 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole – Installation Procedure (4/5)
13. If alarms from the FPMA to the
System Module are needed,
connect the alarm cables.
a) Remove the ingress protection
from the alarm cable connectors in
FPAA and FPBA.
b) Chain the sub-modules together
with the alarm cable from left toright.
c) Connect the alarm cable from oneof the sub-modules to the FPA
connector on the System Module.
14.Connect the DC cables to all the
sub-modules.
15.Push the AC terminal plate all the
way back into its slot.
13a
13b 13c
14
15
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 150/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
150
For internal use only
RA22714EN01GLA0150 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in stack, wall, and pole – Installation Procedure (5/5)
16.Reinsert the ingress protection plate with
cables routed through it.
17.Fix the screw.
18. Install the cable entries.
19.Route the DC power feed cables through
the cable entries and connect them from the
FPMA to the System Module.
20.Check that the cable connectors' seal caps
are firmly in place.
21.Connect the mains power.
22.Power up the site.
23.Turn on the FPAA and FPBA by pushing
the switch.
24. Install the FPMA module front panel cover.
25. If FPBA(s) are used, shortly disconnect the
AC mains power after commissioning.
16
18
17
Note :
For step 23: Turn on the FPAA and FPBA by pushing the switch.
Make sure that the FPAA LED is stable green and the FPBA LED is green and
blinking slowly (charging). To maximise the FPBA life-time, the charging current is
limited. Therefore, it can take up to 12 hours to fully charge an empty FPBA.
For step 25: If FPBA(s) are used, shortly disconnect the AC mains power after
commissioning.
After the site is fully commissioned and integrated, disconnect the AC mains power
for a short while to ensure that the FPMA is able to supply the site and that the 7995
MAINS BREAKDOWN WITH BATTERY BACK-UP alarm is raised on the BTSManager.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 151/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
151
For internal use only
RA22714EN01GLA0151 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in Flexi Cabinet for Indoor (FCIA)
• The following FPMA and FPAA/FPBA combinations are allowed:
• Up to two FPMAs can be connected to one System Module
• If two FPMAs are connected to the same System Module, double rubber boots(822862) are required for safety
• Any combination of up to four FPAAs and FPBAs can be installed in one FPMA
• To find the number of FPAAs required for a configuration, see the sectionCommon cabinet configurations in the documents Creating FCIA configurationsfor Flexi Multiradio GSM/EDGE BTS .
• The FPMA must be located close enough to the System Module so that the alarmcable and DC power cables reach the appropriate connectors without blockingaccess to other modules
• In FCIA, the recommended location for the FPMA is next to the System Module in
the rack.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 152/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
152
For internal use only
RA22714EN01GLA0152 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in Flexi Cabinet for Outdoor (FCOA) – Installation
Procedure1. Remove the connection
pins for the module casing.
2. Remove the support plate
behind the cage nuts.
3. Detach the cage nuts from
the module.
4. Fix the cage nuts (from the
module) on the rack on the
left-hand side of the cabinet.
5. Insert the module.
6. Fix with screws.
7. Connect the mains breaker.
The sub-modules can be installed insidethe FPMA before installing it into thecabinet.
1
2
32
3 3
Before you start
Make sure the mains breaker is off. For FPMA installation locations in Flexi
Multiradio BTS configurations, see Optional
power modules (FPDA and FPMA) in Flexi Multiradio BTS configurations.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 153/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
153
For internal use only
RA22714EN01GLA0153 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in Flexi Cabinet for Indoor (FCIA)
• The following FPMA and FPAA/FPBA combinations are allowed:
• Up to two FPMAs can be connected to one System Module
• If two FPMAs are connected to the same System Module, double rubber boots(822862) are required for safety
• Any combination of up to four FPAAs and FPBAs can be installed in one FPMA
• To find the number of FPAAs required for a configuration, see the sectionCommon cabinet configurations in the documents Creating FCOAconfigurations for Flexi Multiradio GSM/EDGE BTS.
• The FPMA must be located close enough to the System Module so that the alarmcable and DC power cables reach the appropriate connectors without blockingaccess to other modules
• In FCIA, the recommended location for the FPMA is next to the System Module on
the horizontal rack or on the vertical rack closest to the System Module.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 154/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
154
For internal use only
RA22714EN01GLA0154 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in Flexi Cabinet for Indoor (FCOA) – Installation
Procedure (1/2)
1. Remove the connection pins
for the module casing.
2. Remove the cable support
plates from the casings.
3. Remove unit fixing screws
(tx25) and 10mm thick spacer
plates beneath them.
4. Remove gage nuts (4pcs) and
thin support plate (2pcs).
5. Detach the cage nuts and
support plates behind them
from the module.
6. Remove the air separator
plate.
3
2
1
2
33
Before you start
Make sure the mains breaker is off. For FPMA installation locations in Flexi
Multiradio BTS configurations..
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 155/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
155
For internal use only
RA22714EN01GLA0155 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)FPMA in Flexi Cabinet for Indoor (FCOA) – Installation
Procedure (2/2)
7. Fix the cage nuts (from
the module) on the rack
on the left-hand side of
the cabinet.
8. Insert the module.
9. Fix with screws and thick
spacer plates.
10. Connect the mains power.
7 8
Before you start
Make sure the mains breaker is off. For FPMA installation locations in Flexi
Multiradio BTS configurations..
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 156/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
156
For internal use only
RA22714EN01GLA0156 © Nokia S iemens Ne tworks
Installing Flexi Power Module (FPMA)Connecting Power Module alarm cables
• The Power Module (FPMA) alarmcables are connected betweenPower Module submodules.
1. Remove the IP seals from the alarm cableconnectors in the FPAA and FPBA.
2. Chain the sub-modules together with thealarm cable from left to right.
3. Connect the alarm cable from one of thesub-modules to the System Module.
4. Make sure that all connector seals arefirmly in place.
Procedure installation
Notes:
• Incorrect cables and seals may not provide secured weather protection. In outdoor installations,including the outdoor cabinet, use only tested IP65 class outdoor cables with seals provided by
Nokia Siemens Networks. This is also recommended for indoor installations.
• Store all unused seals for later use.
• Risk of damage to equipment. Connector seals or boots must be installed at all times, whether
the site is active or not.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 157/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
157
For internal use only
RA22714EN01GLA0157 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Installing Optional Items/modules:
• Installing Flexi System External Alarm (FSEB)
• Installing Flexi Power Module (FPMA)
• Installing Flexi Power DC/DC Module 24V (FPDA)
• Installing Flexi Power Rectifier (FPRA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 158/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
158
For internal use only
RA22714EN01GLA0158 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Overview
• The FPDA is an isolated 2U-high DC/DC Power Module that converts nominal 24 VDC input voltage to 48 V DC nominal output voltage and 2 kW power.
• When the BTS power load is more than 2 kW, multiple FPDAs can be installed inparallel.
• When FPDAs are used in parallel, a maximum of two DC cables can be installedtogether at each output terminal. This limitation is due to:
• The output current from the FPDA where all three are combined would exceedthe safety limits for the thickness of the DC cables provided in the delivery.
• The safety rubber boots provided in the delivery can accommodate up to twoDC cables per terminal.
• The DC output terminal bolt length can accommodate up to two DC cables perterminal
Before you start
Make sure the mains breaker is off. For FPMA installation locations in Flexi
Multiradio BTS configurations..
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 159/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
159
For internal use only
RA22714EN01GLA0159 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)FPDA provisioning based on number of FPDAs (1/3)
• examples of FPDA provisioning based on the number of FPDAs
CircuitBreaker
FPDA SystemModule
24 VDC 48 VDC
CircuitBreaker
FPDA SystemModule
24 VDC
48 VDC
CircuitBreaker
FPDA24 VDC
48 VDC
CircuitBreaker
FPDA System
Module
24 VDC 48 VDC
CircuitBreaker
FPDA SystemModule
24 VDC
48 VDC
CircuitBreaker
FPDA24 VDC
48 VDC
with one FPDA
with two FPDAs
with three FPDAs twosystem modules(sample 1)
the power draw from the System
module to the single FPDA cannotexceed 2kW.
Note:
•When FPDAs are installed in parallel, the DC output cables should be installed
together at the FPDA closest to the System module.
•Two additional 4 AWG (25 mm2) cable lugs are required for each additional FPDA
used in parallel. These lugs are not included in the delivery and must be sourced
locally.
•When FPDAs are installed in parallel and a power failure occurs in a DC line, the
input voltage to the System module will likely drop below the acceptable level. If an
FPDA is overloaded with power, then the unit will shut itself down.
•In the example in Figure FPDA provisioning for configurations with three FPDAs
and two system modules (sample 1), the power draw from the System module to
the single FPDA cannot exceed 2kW.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 160/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
160
For internal use only
RA22714EN01GLA0160 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)FPDA provisioning based on number of FPDAs (2/3)
• examples of FPDA provisioning based on the number of FPDAs … cont’d
CircuitBreaker
FPDA SystemModule
24 VDC 48 VDC
CircuitBreaker
FPDA SystemModule
24 VDC
48 VDC
CircuitBreaker
FPDA24 VDC
48 VDC
with three FPDAs onesystem module(sample 3)
48 VDC
with three FPDAs twosystem modules(sample 2)
CircuitBreaker
FPDA24 VDC 48 VDC
CircuitBreaker
FPDA
SystemModule
24 VDC
48 VDC
CircuitBreaker
FPDA24 VDC
Note:
•In Figure provisioning for configurations with three FPDAs and one system module
(sample 3), FPDA provisioning requires four pairs of double rubber boots (822862)for safety. The standard delivery for this configuration only includes three pairs of
double roots.
•An extra pair must be ordered as a spare part for combining the DC cables at each
System Module input terminal.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 161/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
161
For internal use only
RA22714EN01GLA0161 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)FPDA provisioning based on number of FPDAs (3/3)
• examples of FPDA provisioning based on the number of FPDAs … cont’d
CircuitBreaker
FPDA SystemModule
24 VDC
48 VDC
CircuitBreaker
FPDA24 VDC
48 VDC
with four FPDAs twosystem modules
CircuitBreaker
FPDA SystemModule
24 VDC
48 VDC
CircuitBreaker
FPDA24 VDC
48 VDC
The FPDA is delivered with two
sets of rubber boots:
• one set accommodates
cable thickness of 35-50
mm2 (2 to 1/0 AWG) for
24 V DC input. Required
cable thickness depends on
the distance and voltage
drop from the external 24 V
DC power supply.
• the other set accommodates up to two 25 mm2 (4 AWG) cables per terminal for 48 V DC
output to the System module. These boots can be used for single or dual DC cables at
each power terminal. Dual usage is required for pairing (chaining) cables when two FPDA
modules are used in parallel as shown in figure Parallel FPDAs with paired (chained) DC
cables and boots.
Note:
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 162/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
162
For internal use only
RA22714EN01GLA0162 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Installation procedure (1/3)
1. Install the FPDA and (in cabinet
installation) fix the module to the
cabinet with screws.
2. Attach the cable entries using
two screws (in stack, wall and
pole installation).
3. Make sure that the power switchon the front panel is in the stand-
by position.
4. Connect the grounding cable to
the plinth (in stack, wall and pole
installation).
23
4
Note:
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 163/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
163
For internal use only
RA22714EN01GLA0163 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Installation procedure (2/3)
5. Remove the bolts and washers
from the DC output terminals.
6. Insert the rubber boots to the DC
output cables.
7. Route the DC output cables
through the cable entry (in stack,
wall and pole installation).
8. Connect the V48N- cable to the
minus terminal and V48RTN+
cable to the plus terminal in the
FPDA module.
9. Tighten the bolts to 10.0 - 14.0Nm (7.0 - 9.8 ft -lb) Nm.
10. Pull the rubber boots over the
DC output terminals.
11. Connect the DC output cables to
the System Module.
5
6
7
8 10
Note:
For no: 6 Insert the rubber boots to the DC output cables.
If the cable is 50 mm2, cut the rubber boot to fit the cable.
If two FPDAs are used in parallel, cut the sealed hole on the DC output boots.
For no: 7 7 Route the DC output cables through the cable entry (in stack, wall
and pole installation).
Use the top right entry hole for the V48N- cable and bottom right entry hole for the
V48RTN+ cable.
For no: 11 Connect the DC output cables to the System Module.
Note that there is a risk of short circuit. Connect the power cable as instructed.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 164/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
164
For internal use only
RA22714EN01GLA0164 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Installation procedure (3/3)
16. Connect the 24 V DC supply (and the battery circuit breaker if the 24 V DC supply
system is a battery back-up system). Make sure the LED is yellow.
17. Switch on the power by pushing the power switch on the front panel of the FPDA. Make
sure the LED is green.
18. Make sure that the unused connectors are covered with seal caps.
19. Install the module front cover ( in stack, wall and pole installation).
12. Remove one of the alarm connector seals on the
front panel of the FPDA and connect the alarm
cable.
13. Check that the power switch on the front panel of
the FPDA is still in the stand-by position.
14. Make sure that the 24 V DC supply for the FPDA is
de-energised and connect the DC input cables
similarly as the DC output cables.
15. 15 Connect the AC mains power for the 24 V DC
supply system.
Note:
For 12 Remove one of the alarm connector seals on the front panel of the
FPDA and connect the alarm cable.
Make sure that you are inserting the cable connector as instructed in the figure.
For no: 14 Make sure that the 24 V DC supply for the FPDA is de-energised
and connect the DC input cables similarly as the DC output cables.
Connect the minus wire to the minus terminal and the plus wire to the plus terminal.
Note that the DC input cables are not included in the delivery. The length and
thicknessof the DC input cables must be defined based on the distance to the 24 V
DC power source. The maximum thickness of a DC input cable that can be installed
to the FPDA is 50 mm²/AWG 1/0
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 165/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 166/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
166
For internal use only
RA22714EN01GLA0166 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Optional power modules combination (FPDA and FPMA)Installation location for 1+1+1 up to 6+6+6 2UD with one RF Module
1+1+1 upto 6+6+6 2UD configuration in a stack,with FPDA
1+1+1 upto 6+6+6 2UD configuration in a stack,with FPMA
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 167/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
167
For internal use only
RA22714EN01GLA0167 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Optional power modules combination (FPDA and FPMA)Installation location for 1+1+1 up to 6+6+6 2UD with one RF Module
1+1+1 upto 6+6+6 2UDconfiguration on a wall, with FPDA
1+1+1 upto 6+6+6 2UDconfiguration on a wall, with FPMA
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 168/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
168
For internal use only
RA22714EN01GLA0168 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Optional power modules combination (FPDA and FPMA)Installation location for 1+1+1 up to 6+6+6 2UD with one RF Module
1+1+1 upto 6+6+6 2UDconfiguration on a pole, with FPDA
1+1+1 upto 6+6+6 2UDconfiguration on a pole, with FPMA
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 169/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 170/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
170
For internal use only
RA22714EN01GLA0170 © Nokia S iemens Ne tworks
Installing Flexi Power DC/DC Module 24V (FPDA)Optional power modules combination (FPDA and FPMA)Installation location for 1+1+1 up to 6+6+6 2UD with one RF Module
1+1+1 up to 6+6+6 2UDconfiguration in FCOA, with FPDA
1+1+1 up to 6+6+6 2UDconfiguration in FCOA, with FPMA
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 171/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
171
For internal use only
RA22714EN01GLA0171 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Installing Optional Items/modules:
• Installing Flexi System External Alarm (FSEB)
• Installing Flexi Power Module (FPMA)
• Installing Flexi Power DC/DC Module 24V (FPDA)
• Installing Flexi Power Rectifier (FPRA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 172/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
172
For internal use only
RA22714EN01GLA0172 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Overview
• The FPRA also includes a Power Distribution Assembly(PDA), which contains a fully integrated battery protectionLVD, load/battery circuit breakers.
• Alarm signals to the BTS Alarm interface are connected to thePDA unit via a pull out Alarm Interface Card.
FPRA Power Distribution Assembly unitFPRA Alarm Interface card
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 173/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
173
For internal use only
RA22714EN01GLA0173 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Principles for installing FPRx in Flexi Multiradio BTS configurations(1/2)
• The FPRx can be installed anywhere in a stack or cabinet provided that the 2 m(6.6 in.) alarm cable can be connected between the FPRx and System Module(System Module).
• In indoor cabinet (FCIA) installations, the recommended location forFPRx is:
• without batteries at the top of the cabinet, near the cabinet roof.
• with batteries near the bottom of the cabinet, in the next available rack space abovethe batteries.
• In outdoor cabinet (FCOA) installations, the recommended location forFPRx is:
• without batteries:
– If batteries are not used, only the FPRB or FPRC can be used in FCOA
– If the System Module (ESMB/C) is in the top vertical rack, install the FPRB/FPRCmodule on the lower vertical rack
– If the System Module is in the horizontal rack, install the module in the top verticalrack.
• with batteries:
– Site Support Module (FCSA) is installed inside the FCOA cabinet
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 174/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
174
For internal use only
RA22714EN01GLA0174 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Principles for installing FPRx in Flexi Multiradio BTS configurations(2/2)
• In Stack installations, the recommended location for FPRx is:
• In outdoor only the FPRC module can be used because of WDR
requirements. Flexi front and back covers must be used.
• For indoor any FPRx can be used.
• Location is the bottom of the stack.
• This allows for easier future expansion because the top sector can be
expanded without the Upgrade RF Cable Kit (EUCA).
• In wall and pole installations, the recommended location for FPRx is:
• Only the FPRC is used in wall and pole installations. Flexi front and back covers
must be used.
• The recommended location is either on the same plinth as the System Module
or on an adjacent plinth
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 175/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
175
For internal use only
RA22714EN01GLA0175 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting FPRA alarms cables
• FPRA delivery does not include any alarm cables.
• The required cables are either supplied with the interconnecting units (FlexiSystem External Alarm (FSEB) and/or Flexi Cabinet Site Support Module(FCSA)) or must be ordered separately depending upon the configuration.
• When using Flexi Power Rectifier (FPRA) with Flexi Cabinet Site SupportModule (FCSA) in an outdoor application, there are three different cablingconfigurations for Flexi Multiradio BTS which can be used depending uponthe number of alarms signals required by the user
FPRA front view
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 176/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
176
For internal use only
RA22714EN01GLA0176 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting FPRA alarms - Overview
• The PDA supplies six isolated and floating EAC alarms to the BTS, whichare summarised in the table below.
• Battery temperature High/Low
• Rectifier temperature High
• Rectifier over current
• Battery test failure
• Rectifier fail
• High float voltage
• Battery low voltage
• PDA controller fail
Remote-start for Battery TestExt Alarm In
• Extended mains voltage range
• Low mains voltage range
Minor
• Rectifier Fan Failure
• Input voltage too high or too low (rectifier shutdown)
• Surge Protection Device failed
Major
• DC distribution failure (e.g. Circuit Breaker tripped)Critical
Main 3
Main 2
Mains phase failure indicates any single phase voltage of the 3-phase FPRA power sourceconfiguration that is below 85 V AC
Main 1
Description (see Tip below the table)EAC alarm
☞ The settings listed in the above table are the factory-default alarm settings. Theuser can re-configure the alarm settings as required.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 177/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
177
For internal use only
RA22714EN01GLA0177 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting FPRA alarms - Connection Procedure
Detaching the Alarm Interface card
Connecting the FPRA alarm cable
1. Detach the Alarm Interface Cardfrom the PDA
2. To insert the cable, puncture thewaterproof seal marked ‘Alarm In’
3. Feed the bare end of the cablethrough the hole.
4. Strip back the outer sleeve of thecable
5. Cut the cable screening back toapproximately 20 mm
6. Connect the screening toposition ‘A’
7. Push the drawer back into itsslot horizontally until the drawerpin matches the
8. internal connector of the PDAand secure the twothumbscrews
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 178/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
178
For internal use only
RA22714EN01GLA0178 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting FPRA to System Module EAC connector
• ECBA Cable 471464A (separate sales item) is needed
FPRASystemModule
471464A
Flying
leadRJ45Connector
MINOR
ALARM_COM
MAJOR
ALARM_COM
CRITICAL
ALARM_COM
MAINS 3
ALARM_COM
MAINS 2
ALARM_COM
MAINS 1
ALARM_COM
ALARM IN (+)
ALARM IN (-)
Name
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J11 pin number
FPRA
EXT_AL6LIGHT GREEN
GNDBLACK/GREEN
EXT_AL5PINK
GNDBLACK/RED
EXT_AL4GREY
GNDWHITE/GREY
EXT_AL3VIOLET
GNDWHITE/VIOLET
EXT_AL2BLUE
GNDWHITE/BLUE
EXT_AL1GREEN
GNDWHITE/GREEN
+5VWHITE/BLACK
EXT_CO1BLACK
EAC signalColor
FSAA cable
EAC connections
Steps:
1. Cut the 37 way D-type connector from cable assembly 471628A, leaving the MDR- 36
connector intact.
2. Insert the cable into the alarm module as described in Connecting Flexi Power Rectifier
(FPRA) alarm cable.
3. Connect the twisted pair cables to the J11 connector
4. Secure the alarm cable to the drawer sidewall with a cable tie.
5. Push the drawer back into its slot horizontally until the drawer pin matches the internal
connector of the PDA and secure the two thumbscrews.
6. Connect the MDR36 connector to the EAC connector of the System Module.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 179/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
179
For internal use only
RA22714EN01GLA0179 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting FPRA to System Module FPA connector
• ECBA Cable 471464A (separate sales item) is needed
FPRASystemModule
471464A
Flying
leadRJ45Connector
COMMINOR
MAJOR
CRITICAL
MAINS 3
MAINS 2
MAINS 1
Name
314
12
10
8
6
4
J11 pin number
FPRA
GND776146
76135
76121
79952
79953
79954
FPA signalRJ45 wire number
Cable 471464A
FPA connections
Steps:
1. Cut the 9 way D Type connector from cable assembly 471464A.
2. Use a DVM to find which wire is connected to Pins 1-8 on the RJ45 connector, becausecable assembly 471464A is not color-coded.
3. Connect the wires to the J11connector
4. Make sure that any unused wires are insulated and sleeved.
5. Secure the alarm cable to the drawer sidewall with a cable tie.
6. Push the drawer back into its slot horizontally until the drawer pin matches the internal
connector of the PDA and secure the two thumbscrews.
7. Connect the RJ45 connector to the FPA connector of the Flexi System Module.
Note that FPRA Alarm outputs must be configured for “active closed” (closed on Alarm)
when using FPA Alarm Input. See the FPRA User Manual for details of alarm settings.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 180/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
180
For internal use only
RA22714EN01GLA0180 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting FPRA to Flexi System External Alarm (FSEB)
• 994945 (supplied with FSEB) & 471628A (separate sales item) areneeded
EXT_AL44X4106GREY10CRITICAL
EXT_AL55X4106PINK12MAJOR
X4106
X4106
X4106
X4106
X4107
X4105
X4104
Connector
LIGHTGREEN
VIOLET
BLUE
GREEN
WHITE/GREEN
WHITE/BLACK
BLACK
Wirecolour
14
8
6
4
3
2
1
J11pin
MINOR
MAINS 3
MAINS 2
MAINS 1
ALARM_COM
ALARM IN (+)
ALARM IN (-)
Description
FPRA
EXT_AL66
EXT_AL33
EXT_AL22
EXT_AL11
GND1
+5V1
EXT_CO11
EACsignal
Pinnumber
FSEB
FSEB connections
Connecting FPRA to Flexi SystemExternal Alarm (FSEB)
Steps:
1. Connect alarm cable 994945 from the EAC connector on the System Module to the ESM
connector of the FSEB.
2. Cut both connectors from cable assembly 471628A leaving just the cable itself.
3. Insert one end of the cable into the Alarm Interface Card as described in Connecting Flexi
Power Rectifier (FPRA) alarm cable.
4. Connect the wires between the J11 connector of the Alarm Interface Card and the alarms
connector located in the FSEB box
5. Secure the alarm cable to the side wall with a cable tie.
6. Push the drawer back into its slot horizontally until the drawer pin matches the internal
connector of the PDA and secure the two thumbscrews.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 181/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
181
For internal use only
RA22714EN01GLA0181 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting 3 FPRA alarms and 4 FCSA alarms
• 994957 (supplied with FCSA), 994945 (supplied with FSEB) &994157 (separate sales item) are needed
COM
MAINS 3
MAINS 2
MAINS 1
Name
3
8
6
4
J11 pinnumber
FPRx
GND
MAINS #3
MAINS #2
MAINS #1
FCSAalarm
ORANGE/WHITE
WHITE/GREY
WHITE/BROWN
WHITE/GREEN
Colour
Cable 994157
Cable 994157 connectionsConnecting 3 FPRA alarms and 4 FCSA alarms
Steps:
1. Connect alarm cable 994945 from the EAC connector on the System Module to the ESM
connector of the FSEB.
2. Connect alarm cable 994957 from the Ext Alarms Output connector on the FCSA control
card to the external alarms connector located in the FSEB box.
3. Cut one of the 9-way D-Type connector from cable assembly 994157, leaving the other
end intact.
4. Insert the cable into the Alarm module as described in Connecting Flexi Power Rectifier
(FPRA) alarm cable.
5. Connect the cables to the J11 connector as shown in the table below.
6. Secure the alarm cable to the drawer side wall with a cable tie.
7. Push the drawer back into its slot horizontally until the drawer pin matches the internal
connector of the PDA and secure the two thumbscrews
8. Connect the 9-way D-type connector to the MIBBU connector of the FCSA Control Card.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 182/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
182
For internal use only
RA22714EN01GLA0182 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting 6 FPRA alarms and 4 FCSA alarms using ECBA cable
• 994957 (supplied with FCSA), 994945 (supplied with FSEB) &471464A (ECBA cable, separate sales item) are needed
76135MAJOR12
76121CRITICAL10
76146MINOR14
COM
MAINS 3
MAINS 2
MAINS 1
Name
3
8
6
4
J11 pinnumber
FPRx
GND
7995
7995
7995
FPAalarm
7
2
3
4
RJ45 wirenumber
Cable 471464A
Cable 471464A connectionsConnecting 6 FPRA alarms and 4FCSA alarms using ECBA cable
Steps:
1. Connect alarm cable 994945 from the EAC connector on the System Module to the ESMconnector of the FSEB.
2. Connect alarm cable 994957 from the Ext Alarms Output connector on the FCSA control card tothe external alarms connector located in the FSEB box.
3. Cut the 9-way D Type connector from cable assembly 471464A, leaving the RJ45 end intact.
4. Use a DVM to find which wire is connected to Pins 1-8 on the RJ45 connector, because cableassembly 471464A is not color-coded.
5. Insert the cable into the Alarm module as described in Connecting Flexi Power Rectifier (FPRA)alarm cable.
6. Connect the cables to the J11 connector
7. Secure the alarm cable to the drawer side wall with a cable tie.
8. Push the drawer back into its slot horizontally until the drawer pin matches the internal connectorof the PDA and secure the two thumbscrews.
Note that FPRA Alarm outputs must be configured for “active closed” (closed on Alarm)
when using FPA Alarm Input.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 183/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
183
For internal use only
RA22714EN01GLA0183 © Nokia S iemens Ne tworks
Installing Flexi Power Rectifier (FPRA)Connecting 6 FPRA alarms and 4 FCSA alarms
• 994957 (supplied with FCSA), 994945 (supplied with FSEB) &995239 (supplied with FCSA) are needed
FSEB connectionsConnecting 6 FPRA alarms and 4 FCSA alarms
EXT_AL44X4106GREY10CRITICAL
EXT_AL55X4106PINK12MAJOR
X4106
X4106
X4106
X4106
X4107
X4105
X4104
Connector
LIGHTGREEN
VIOLET
BLUE
GREEN
WHITE/GREEN
WHITE/BLACK
BLACK
Wirecolour
14
8
6
4
3
2
1
J11pin
MINOR
MAINS 3
MAINS 2
MAINS 1
ALARM_COM
ALARM IN (+)
ALARM IN (-)
Description
FPRA
EXT_AL66
EXT_AL33
EXT_AL22
EXT_AL11
GND1
+5V1
EXT_CO11
EACsignal
Pinnumber
FSEB
Steps:
1. Connect alarm cable 994945 from the EAC connector on the System Module to the ESM
connector of the FSEB.
2. Connect alarm cable 994957 from the Ext Alarms Output connector on the FCSA control
card to the external alarms connector located in the FSEB box.
3. Cut the 9-way D-Type connector from cable assembly 995239, leaving just the cable itself.
4. Insert one end of the cable into the Alarm Interface Card as described in Connecting Flexi
Power Rectifier (FPRA) alarm cable.
5. Connect the wires between the J11 connector of the Alarm Interface Card and the alarms
connector located in the FSEB box
6. Secure the alarm cable to the drawer side wall with a cable tie.
7. Push the drawer back into its slot horizontally until the drawer pin matches the internal
connector of the PDA and secure the two thumbscrews.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 184/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
184
For internal use only
RA22714EN01GLA0184 © Nokia S iemens Ne tworks
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 185/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
185
For internal use only
RA22714EN01GLA0185 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Cabling Principles for Flexi Multiradio BTS GSM/EDGEInstallation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 186/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
186
For internal use only
RA22714EN01GLA0186 © Nokia S iemens Ne tworks
Cabling principles in stack, wall, and poleinstallation (1/2)
• Cables are routed along the sides of the modules. Excess cabling should be tiedto clamps.
• In stack installations, cables are routed out both the left and right cable entries..
• All cables except the optical cables can be routed in either direction aslong as they do not violate the bending diameter or block access to otherused connectors.
• The optical cable must always be routed to the left . It is alsorecommended to route the internal power cable in the same path as theoptical cable for each module.
• Antenna jumper cables can be routed out the left side, right side, orboth sides. However, access to the optical and internal power cablesduring maintenance and expansion is easier when all antenna jumpercables are routed to the right.
• Internal cable entries are not typically used with Flexi Multiradio BTS.
• When preparing the external cable entries, cut a slit in the cable entry for routingthe cables.
• In wall and pole installation, cables should be routed through the bottomcable entry whenever possible.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 187/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
187
For internal use only
RA22714EN01GLA0187 © Nokia S iemens Ne tworks
Cabling principles in stack, wall, and poleinstallation (2/2)
• Internal power cables (PWR)
• External 24 V DC power cables
• External 48 V DC power cables (If
• EAC connector is used)• Optical cables (OPT)
• External AC power cables
• Flexi power alarm cable (FPA)
• Grounding cables
External cableentries (left side)
Antenna jumper cables (ANT), RF cables (RxO), and transmissioncables (FIxx) can be routed out either side of the module, depending onthe location of the interface with respect to the cabinet
External cableentries (rightside)
Cable entry
• External 48 V DC power cables (if
• EAC connector is not used)
• Grounding cables
• Optical cables with FIQA and FIYA (OPT)
• Optional cables:
• External alarm and control (EAC)
• Synchronisation (SYNC OUT, SYNC IN)
• Q1 interface (Q1)
• Location management unit (LMU)
Cables
Recommended cable routing principles in stack installation
Note: In large configurations,mark cables for identificationduring maintenance.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 188/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
188
For internal use only
RA22714EN01GLA0188 © Nokia S iemens Ne tworks
Optional cable tunnels in stack, wall, and poleinstallation
• The optional cable tunnels can be used to hide excess cabling on theside of stack or pole configurations. Cable tunnels are not required forweather protection.
• Follow the below listed principles for the cable tunnels to fit properly:
• Route the external cables on the right side of the BTS, and tie allcabling in between the top and bottom square holes on the supportplates.
• Route the internal cables on the left side of the BTS, and tie all sidecabling as follows, using the square holes on the support plates asguides:
• For vertical routing, tie the cables in between the beginning of the
front hole and beginning of the rear hole.• For horizontal routing, tie the cables in between the top and bottom
square holes.
• Do not route internal cables through the back .
• Remove the ears from cable entries before installation
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 189/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
189
For internal use only
RA22714EN01GLA0189 © Nokia S iemens Ne tworks
Internal power cabling principles for SystemModule (ESMB/C)
• The following main principles for internal power cabling apply to RFModule (FXxx).
• For stack and cabinet configurations, RF Modules can be numbered 1to 4 from bottom to top. The power connection ports used on theSystem Module (ESMB/C) should match the RF Modules numbering.
• In wall configurations, numbering can be from 1 to 4 from bottom to top,with the lower number for each plinth corresponding to the RF Moduleclosest to the wall (the RF Module connected directly to the plinth).
• In pole configurations, the RF Module closest to the System Moduleshould correspond with port 1 for PWR on the System Module.
• Numbering applies to optical cables and any numbering order can be
followed.• Also, it is recommended that optical and power cable numbering should
match for each RF Module, when the RF Module is powered by theSystem Module.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 190/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
190
For internal use only
RA22714EN01GLA0190 © Nokia S iemens Ne tworks
Bending Diameter for Cables for Flexi MultiradioBTS GSM/EDGE
• The table below shows the minimum bending diameter of Flexi Multiradio BTScables.
• Static bending diameter refers to the allowed bend while the cable is fixed (forexample, when the cable is tied to the side of the cabinet).
• Dynamic bending diameter refers to the allowed bend while the cable is in motion(for example while routing the cable through the cable entry).
170 mm (6.7 in.)117 mm (4.6 in.)995281Power cable
140 mm (5.6 in.)140 mm (5.6 in.)Optical cables
45 mm (1.8 in.)40 mm (1.6 in.)471370
471371
471372
471377
471384
471464
471521
EMCA LMP cable
Sync cable for Flexi
Sync cable for Ultra-Site
Sync LMU cable
Q1 cable
MIBBU EPA alarm cable
Clock test cable
Transmission cable
Cable CodeCable name
Cable Dynamic bendingdiameter
Static bendingdiameter
Bending diameter of Flexi Multiradio BTS cables
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 191/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
191
For internal use only
RA22714EN01GLA0191 © Nokia S iemens Ne tworks
Content
Preparation of Flexi Multiradio BTS GSM/EDGE installation
Flexi Multiradio BTS GSM/EDGE Installation Option
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole (SWP) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Indoor (FCIA) Installation
Flexi Multiradio BTS GSM/EDGE with Flexi Cabinet for Outdoor (FCOA) Installation
Flexi Multiradio BTS GSM/EDGE Feederless Solution
Flexi Multiradio BTS GSM/EDGE Optional Items/Modules Installation
Cabling Principles for Flexi Multiradio BTS GSM/EDGE Installation
Installation tools and torque values for Flexi Multiradio BTS GSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 192/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
192
For internal use only
RA22714EN01GLA0192 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Installation tools and torque values for Flexi Multiradio BTSGSM/EDGE
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 193/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
193
For internal use only
RA22714EN01GLA0193 © Nokia S iemens Ne tworks
Installation Tools for Flexi Multiradio BTSGSM/EDGE (1/4)
• This list provides a reference for installation tools required for all Flexi MultiradioBTS installation options.
• These options are stack, wall, pole, Flexi Cabinet for Indoor (FCIA), Flexi Cabinetfor Outdoor (FCOA), feederless sites, and installation in legacy and 3rd partycabinets.
• Installing modules (T25)
• Installing casing kits (T25)
• Module grounding (T25)
• FCIA/FCOA/FCFA/FCSA/FMFA mechanics (T25)
• Installing sub-modules (T20)
• Fan plate assembly (T20)• Anchoring EMIA standoff casing and EMIB rack
plinth (T45)
• FCIA site grounding (T45)
• Isolating cable clamps (T10)
• EMIA or EMIB door alarm kit (T10)
TORX screwdriver set: T10, T20, T25, T45
Module/sub-module installationESD wrist strap and cable
UsageInstallation tools
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 194/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
194
For internal use only
RA22714EN01GLA0194 © Nokia S iemens Ne tworks
Installation Tools for Flexi Multiradio BTSGSM/EDGE (2/4)
• Connecting antenna cables to FXxxTorque wrench for antenna cables (sizedepends on antenna jumper/feeder cable sizeand manufacturer)
• RS Torque wrench 25 Nm, 27/32 mm (CS77564.20)
• RS Torque wrench 1.7 Nm, 19 mm (CS77507.30)
Torque wrench (7/16 in.)
• Cutting tie wraps, general installation toolSide cutters
• Grounding and DC power input cablesCrimping tool for 16 mm2 (6 AWG), 25 mm2
(4 AWG), 35 mm2 (2 AWG), or 50 mm2(1/0 AWG) cable lugs
• General installation tool Adjustable wrench
• Unpacking
• Routing cables through cable entries
• Preparing power and ground cables
Folding knife
• DC power terminal nuts (17 mm)
• Plinth site grounding (13 mm)
• FCOA site grounding (13 mm, 8 mm)
• Anchoring cabinets/plinths (19 mm)
Socket or open-ended spanner (wrench) set: 8mm, 13 mm, 17 mm, 19 mm Torque wrench isrecommended for fastening the DC input lug.
UsageInstallation tools
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 195/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
195
For internal use only
RA22714EN01GLA0195 © Nokia S iemens Ne tworks
Installation Tools for Flexi Multiradio BTSGSM/EDGE (3/4)
• VMPB/FPKA pole mounting kit (8 mm)
• EMIA or EMIB installation (4 mm, 5 mm, 6 mm)
• Feederless sites (grounding kit) (5 mm)
Allen (Hexagon) keys:
4 mm (5/32 in.), 5 mm (3/16 in.), 6 mm (7/32 in.), 8mm (5/16 in.)
General installation toolLevel
FPMA AC power terminalsFlathead screwdriver
• Anchoring cabinets/plinths (12 mm)
• EMIB rack plinth rivet holes (5 mm)
• EMIB top support C-plate fixing holes (6 mm)
• EMIA/EMIB Citytalk cabinet bottom plate waterholes (13 mm)
• Grommet hole drilling (64 mm, Bi-metal hole saw)
Drill with bit set:
For EMIA: 10 mm (3/8 in.) - 13 mm (1/2 in.)
For EMIB: 5 mm (3/16 in), 6 mm (7/32 in), 10 mm(3/8 in.), 13 mm (1/2 in), 64 mm (2 1/2 in.), Bi-metalhole saw
General installation toolMarker, pen, or comparable tool
General installation toolPliers
General installation toolFlashlight, pocket lamp or torch
General installation toolTape measure
Routing cablesCable ties
UsageInstallation tools
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 196/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
196
For internal use only
RA22714EN01GLA0196 © Nokia S iemens Ne tworks
Installation Tools for Flexi Multiradio BTSGSM/EDGE (4/4)
Flexbus Jumper Cable and Outdoor Flexbus cableconnection
Weatherproof protection tape
Feederless sitesHeat gun for cable shrinking sleeves
Cleaning the optical connectorsLint-free swabs
Cleaning the optical connectors99% alcohol
Feederless sitesHand saw
EMIA or EMIB installationVacuum cleaner or broom with dust pan
Installation on a pole or wall FMSAThread locking compound (medium strength, nonpermanent), for example Loctite 242 or equivalent
UsageInstallation tools
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 197/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
197
For internal use only
RA22714EN01GLA0197 © Nokia S iemens Ne tworks
Torque Values for Flexi Multiradio BTS GSM/EDGE(1/2)
• Nokia Siemens Networks strongly recommends that you tighten to the followingtorque values.
• Use these values unless stated otherwise.
1.2 - 1.6 Nm (0.9 - 1.2 ftlb)FCSA and FCFA fansScrew, TORX cylinderhead
M4
2.7-3.3 Nm (1.99-2.43 ftlb)• FIxx installation
• ESMB/C, FXxx, and FPDA
fanplate assembly• FMAA
Screw, TORX pan head or
thumb (knurled head)
M4
3.0 Nm (2.21 ft-lb)FCOA site groundingNut, HexM5
Screw, Allen or TORX head
Screw, TORX pan head
Type
M6
M3
Size
4.2-5.8 Nm (3.1-4.28 ft-lb)• EMIA and EMIB
• FMAA
0.7 - 1.0 Nm (0.52 -0.74 ft-lb)EMIA and EMIB
TorqueUsage
Torque wrenchTorque values for the BTS
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 198/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
198
For internal use only
RA22714EN01GLA0198 © Nokia S iemens Ne tworks
Torque Values for Flexi Multiradio BTS GSM/EDGE(2/2)
10.0 - 14.0 Nm (7.0 - 9.8 ft -lb)ESMB/C, FPDA and EOCADCpower terminals
Nut, HexM10
30.0 Nm (22.9 ft-lb)VMPB/FPKA/FMFA polemounting kits
Bolt, Allen headM10
49.0 Nm (36.1 ft-lb) Anchoring FCIA/FCOA/FMFAto floor (not included in Flexi
Multiradio delivery)
Anchoring boltsM12(15/32
in.)
5.0 Nm (3.68 ft-lb)FCOA site groundingNut, HexM8
10.0 Nm (7.37 ft-lb)Plinth adapter mechanicsScrew, hex headM8
20.0 Nm (14.74 ft-lb) Attaching FMFA to FPKAScrew, hex headM8
Antenna connector
Screw, TORX or hex head
Type
7/16 DIN
M8
Size
25.0 Nm (18.5 ft-lb Antenna jumper cables (notincluded in Flexi Multiradiodelivery)
8.0-10.0 Nm (5.9-7.37 ftlb)FCIA/EMIA/EMIB/plinth sitegrounding
TorqueUsage
Torque values for the BTS …cont’d
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 199/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
199
For internal use only
RA22714EN01GLA0199 ©Nokia S iemens Networks
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 200/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
200
For internal use only
RA22714EN01GLA0200 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Appendix - Common Configuration
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 201/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
201
For internal use only
RA22714EN01GLA0201 © Nokia S iemens Ne tworks
Common ConfigurationExamples of Flexi Multiradio BTS configurations
3 Pipe RFM 1800
ESMB System Module
3 Pipe RFM 900
S y s m o d u l e
E S M B
3 Pipe RFM
3 Pipe RFM
ESMC
Wall/PoleUp to 6/6/6
ESMC System Module
3 Pipe RFM
3 Pipe RFM
ESMC
3 Pipe RFM
StackUp to 12/12/12
Dual band900 8/8/8@15W1800 4/4/4@15W
FSMx Multimode SM
HEX
FAN batt
LTE
batt batt batt
F S M x
3 Pipe RFM
ESMC
3 Pipe RFM
3 Pipe RFM
Outdoor cabinet with batteriesConcurrent Mode @20W/carrier900 GSM 4/4/4, WCDMA 2/2/2
1800 GSM 2/2/2, LTE 1/1/1
ESMC
FRMx
3 Pipe RFM
3 Pipe RFM
3 Pipe RFM
3 Pipe RFM
ESMC
3 Pipe RFM
3 Pipe RFM
ESMC
Indoor Cabinet36/36/36 with Multi BCF
FRMx with 3 modules (6KW)
LTE
LTE
FRMx
*LTE Line Terminat ing equipment
For the configurations where the number of antennas is specified as X or Y:
• X = the number of antennas required for 1UD and antenna-optimised
configurations
• Y = the number of antennas required for 2UD configurations
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 202/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
202
For internal use only
RA22714EN01GLA0202 © Nokia S iemens Ne tworks
Common ConfigurationCommon Sector Configuration
1 or 21No40 –201 (2G) – 1 (3G)
20 –40
1 or 21No20 –202 (2G) – 1 (3G)
10 –40
1 or 21No10 –303 (3G) – 1 (3G)
2 or 42Yes20 –402 (2G) – 1 (3G)
2 or 42Yes20 –204 (2G) – 2 (3G)
22 or 4Yes601 IDD
22 or 4Yes602 IDD
42 or 4Yes304 IDD
22Yes30/301 IDD nad2 non-IDD
2 or 43Yes306
2 or 42Yes1012
2 or 42Yes158
22Yes206
22Yes304
Yes
No
No
No
No
No
Antennaoptimized
22602
1 or 21106
1 or 21154
1 or 21203
1 or 21302
1 or 21601
# of antennas# of RFbranches
(pipes)
Max Tx Power # of carriers(2G-3G)
For the configurations where the number of antennas is specified as X or Y:
• X = the number of antennas required for 1UD and antenna-optimised
configurations
• Y = the number of antennas required for 2UD configurations
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 203/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
203
For internal use only
RA22714EN01GLA02 03 ©N o ki a Si em en s Ne tw orks
Common ConfigurationDedicated 2G Configuration
3 ***)
2
2
2
2
1
# of FPDA *)
1
1
1
1
1
1
# ofESMB/C
2454Four unchained RF
Modules 4+4+4 up to 12+12+12 2UD
1843Three unchained RF
Modules 3+3+3 up to 12+12+12 2UD
1232Two unchained RF
Modules 2+2+2 up to 12+12+12 2UD
1843Three chained RF
Modules 3+3+3 up to 12+12+12 2UD
1232Two chained RF
Modules 2+2+2 up to 12+12+12 2UD
621Unchained RF
Module 1+1+1 up to6+6+6 2UD
#antennas
# of FPAA *)**)
# of FXxxConfigurations )
*) Optional depending on the external power source. The number of power modules is based on maximum power
consumption and does not account for redundancy.
**) One FPMA supports up to four FPAAs. FPBAs may also be installed in the FPMA.
***) An FSEC is also required since a maximum of two FPDAs can be installed in parallel for each System Module.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 204/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
204
For internal use only
RA22714EN01GLA02 04 ©N o ki a Si em en s Ne tw orks
Common ConfigurationAntenna-optimised configurations
2
2
1
# of FPDA*)
1
1
1
# ofESMB/C
1843Three chained RF
Modules antenna optimised
3+3+3 up
to 12+12+12 2UD
1232Two chained RF
Modules antenna optimised
2+2+2 up
to 12+12+12 2UD
1221One RF Module
antenna optimised 2
up to 12 OMNI 2UD
#antennas
# of FPAA*) **)
# of FXxxConfigurations)
*) Optional depending on the external power source. The number of power modules is based on maximum powerconsumption and does not account for redundancy.
**) One FPMA supports up to four FPAAs. FPBAs may also be installed in the FPMA.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 205/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
205
For internal use only
RA22714EN01GLA0205 © Nokia S iemens Ne tworks
Concurrent ConfigurationCommon Sector Configuration
RFM 900 shared withGSM in concurrentmode
RFM 900 shared withGSM in concurrentmode
RFM 900 shared withGSM in concurrentmode
RFM 900 shared withGSM in concurrentmode
WCDMA HW ModuleSystem Module:FSMD/E
No extension module
RFM 900 shared withWCDMA in concurrentmode
RFM 1800 in dedicated
mode
Dual band conf #1:
1800: 2+2+2 30W
900: 1+1+1 40W
Dual band conf #2:
1800: 6+6+6 10W
900: 4+4+4 10W
Single band 900:
1+1+1 8/20W
1 RFM 900 shared withWCDMA in concurrentmode
1RFM 900 in dedicatedmode
Single band 900:
4+4+4 20W
Single Band 900:
1+1+1 40W
RFM 900 shared withWCDMA in concurrentmode
Single band 900:
1+1+1 40W
2+2+2 20W
4+4+4 10W
Single Band 900:
1+1+1 8/20W
RFM 900 shared withWCDMA in concurrentmode
Single band 900:
1+1+1 10/20W
2+2+2 10/20W
Single band 900:
1+1+1 8/20/40W
GSM HW Modules
System Module: ESMB
GSM ConfigurationWCDMA Configuration
WCDMA and GSM concurrent mode configurations
• Flexi Multiradio BTS is a multiradio BTS, which means that multiple radio technologies can be
used concurrently.
• The 3-branch RF Module supports GSM/EDGE and WCDMA simultaneously.• The System Modules are separate for GSM/EDGE and for WCDMA.
• The GSM/EDGE System Module (ESMB/C) supports up to 18 or 36 TRX capacity, that is, two 3-
branch RF Module capacity, and it has power and OPT connections for four radios (or radio
chains) or System Modules.
• In the concurrent mode, the RF Modules as well as the antenna lines can be shared between
the System Modules and different radio technologies.
• The System Modules have to be interconnected in concurrent operation.
• The Flexi Multiradio BTS is seen as a separate logical network element for different radio
technologies with common radio resources.
• In concurrent mode either ESMB/C or FSMx can be the synchronization master of Flexi
Multiradio BTS while the other is the slave.
• The operator can define the synchronization master while commissioning the BTS.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 206/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
206
For internal use only
RA22714EN01GLA0206 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Appendix - Content of Delivery
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 207/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
207
For internal use only
RA22714EN01GLA0207 © Nokia S iemens Ne tworks
Content of DeliveryPower Module (FPMA)
2• M5 screws for fixing thecasing to another casingor plinth
10• Cable ties
4• K30 screws for the cable
clamps
2• Cable clamps
4• M5 screws for fixingcableentries to the casing
1• Alarm cable to theSystem Module
2• Power Module cableentries (identical toEMHA cable entries)
1470139APower Module (FPMA)with internal AC and DCcabling and cablesupport plates
QuantityProductCode
Description
Power Module (FPMA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 208/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
208
For internal use only
RA22714EN01GLA0208 © Nokia S iemens Ne tworks
Content of DeliveryPower AC/DC sub-module (FPAA) and power battery sub-
module (FPBA)
2• M5 screws for fixing theFPAA to FPMA
1• Alarm cable
1470140APower sub-module(FPAA) with two RJ-45connector seal capsinstalled
QuantityProductCode
Description
Power AC/DC sub-module (FPAA)
2• M5 screws for fixing theFPBA to FPMA
1• Alarm cable
1470140APower battery sub-module (FPBA) with twoRJ-45 connector sealcaps installed
QuantityProductCode
Description
power battery sub-module (FPBA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 209/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
209
For internal use only
RA22714EN01GLA0209 © Nokia S iemens Ne tworks
Content of Delivery24V Power Module (FPDA)
2• Cable clamps
4• K30 screws for cableclamps
4• M5 screws for fixing cable
entries to the casing andM5 screws for fixing thecasings to each other
1• Alarm cable
4• AWG 4 (25 mm2)connector single rubberboot
2• DC output power cables
2• Cable entries
1470139ADC/DC converter corepreinstalled inside a 2Ucasing with cablesupport plates and withtwo RJ-45 connector sealcaps installed
QuantityProductCode
Description
24V Power Module (FPDA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 210/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
210
For internal use only
RA22714EN01GLA0210 © Nokia S iemens Ne tworks
Content of DeliveryFlexi System External Alarm Module (FSEB)
3• Cable tie, PER31
1• D37 Cable Assembly
1471424AFlexi System ExternalAlarmModule (FSEB)
QuantityProductCode
Description
Flexi System External Alarm Module (FSEB)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 211/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
211
For internal use only
RA22714EN01GLA0211 © Nokia S iemens Ne tworks
Content of DeliveryFlexi Pole Installation Kit (FPIA)
1Straining strap
4M5 screws
1Installation plate
QuantityProductCode
Description
Flexi Pole Installation Kit (FPIA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 212/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
212
For internal use only
RA22714EN01GLA0212 © Nokia S iemens Ne tworks
Content of DeliveryFlexi Pole Mounting Kit (FPKA)
6• Module fixing screws
2• Assembling bolts
2• Bolt restrainer
2• Aluminium castings
QuantityProductCode
Description
Flexi Pole Mounting Kit (FPKA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 213/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
213
For internal use only
RA22714EN01GLA0213 © Nokia S iemens Ne tworks
Content of DeliveryPole Mounting Kit delivery (VMPB)
8• M8 x 25 bolts
4• M10 x 200 bolts
4• M10 x 300 bolts
4• M10 x 120 bolts
2• Block
4• Washers
1469978APole Mounting Kit(VMPB)
QuantityProductCode
Description
Pole Mounting Kit delivery (VMPB)
Blocks
M10x120 bolts M8x25 bolts
M10x200 bolts M10x300 bolts washer
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 214/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
214
For internal use only
RA22714EN01GLA0214 © Nokia S iemens Ne tworks
Content of DeliveryFlexi Cabinet for Indoor (FCIA)
4
822083
6332594
Site packs; the site packs
are attached with cableties inside the cabinet.
Contents of site package 1:
• Guide plates
Contents of site package 2:
• Loose cage nuts
4Cage nuts; pre-installed forthe followingconfigurations:
• 1+1+1/2+2+2 bypass
• 3+3+3/4+4+4 2-wayWBC (34 cage nutsare pre-installed and28 are loose in sitepack)
26490006Cabinet key
1469978AFlexi Cabinet for Indoor(FCIA)
QuantityProductCode
Description
Flexi Cabinet for Indoor (FCIA)
1800
600600
FCIA, Flexi indoor cabinet36 Height Units
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 215/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
215
For internal use only
RA22714EN01GLA0215 © Nokia S iemens Ne tworks
Content of DeliveryFlexi Mounting Kit for Batteries (FMBB)
8• Cage nuts
3• Cable ties
1•Back plate
1•Front plate
1• Battery fixing adjuster
14•M5 X 10 screws
1• Bottom plate
1469978AFlexi Mounting Kit forBatteries (FMBB):
QuantityProductCode
Description
Flexi Mounting Kit for Batteries (FMBB)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 216/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 217/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
217
For internal use only
RA22714EN01GLA0217 © Nokia S iemens Ne tworks
Content of DeliveryFlexi Mounting Shield 6U (FMSA)
6• Cable tie point plates
1• Grounding cable betweenthe cabinet and plinth
3•Cable entry
4•M8 screws
6• Module grounding cable
1471650AFlexi Mounting Shield18U (FMSB)
QuantityProductCode
Description
Flexi Mounting Shield 18U (FMSB)
Note:
• Weight 20 kg (empty)
• Flexi Plinth FMFA Required FMSBassembled at site (flat pack delivery)
• vandal protection for floor stack
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 218/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
218
For internal use only
RA22714EN01GLA0218 © Nokia S iemens Ne tworks
Content of Delivery3 U Module Casings (EMHA)
6 (2 loose, 4preinstalled)
• Cage nuts
2• M5 x 6 screws
2• Maintenance straps
1• Grounding cable
1• 3 U front cover
1•3 U rear cover
4•M5 x 10 screws
2• 3 U cable entries
1470316A3 U casing (EMHA)
QuantityProductCode
Description
3 U Module Casings (EMHA)
2. Casing(metal)
3. Front cover(plastic)
1. Rear cover (plastic)
Note: Casings are not a part of themodule sales item and needs to beordered separately for stack/wall/polemounting
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 219/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
219
For internal use only
RA22714EN01GLA0219 © Nokia S iemens Ne tworks
Content of Deliverymounting kit for floor, wall and pole (FMFA)
12• M5x8 screws
1•M5x12 screws
2• Fixing plate for the casing
1470149AMounting kit for floor, walland pole
QuantityProductCode
Description
mounting kit for floor, wall and pole (FMFA) v. 104 delivery content
12• M5x8 screws
2• M5x12 screwsFixing platefor the casing
26• Spring washers (18 pcs forM5 screws and 8 pcs for M8screws)
8• M8x20
1• Adapter mechanics (used inwall and pole installationsonly)
1470149AMounting kit for floor, walland pole
QuantityProductCode
Description
mounting kit for floor, wall and pole (FMFA) v. 103 delivery content
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 220/237
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 221/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
221
For internal use only
RA22714EN01GLA0221 © Nokia S iemens Ne tworks
Content of DeliveryLong Term Battery Backup Solution (MIBBU)
1CS7000009• Battery box plinth
1CS7000008• Battery box
1CS7000010• Battery box wall mounting kit
1CS71362.03• Power safe batt 4x12V92F92Ah/10h
1CS7000002• Surge protection device
1CS7000001• Rectifier AA2500L 48/2000
1471020A• Flexi mounting kit for batteries (FMBA)
1471459A• Flexi battery mounting kit (FMBB)
1CS7136211• Powersafe batt 4x12V62F 48V- 62Ah
1CS7000011• Battery box Flexi bracket kit
1
1
1
1
CS7000000
CS7000003
CS7000005
CS7000007
Flexi Power Rectifier (FPRA)
• PDA Unit
• Temperature Sensor
• Accessory bag
1
1
469784A
469950A
WPxx
• Power Distribution Unit (WPUB)
• Wideband Power Unit (WPMB)
Quan-tity
ProductCode
Description
Long Term Battery Backup Solution (MIBBU)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 222/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
222
For internal use only
RA22714EN01GLA0222 © Nokia S iemens Ne tworks
Content of DeliveryTalk Conversion Kit (EMIA)
1• Front door assembly
1• Back wall assembly
2• Upper lock rod supports
16• M5 x 10 TORX screws
4• M3 x 6 TORX screws
4• Connection pins
4• M8 x 16 screws
4• Washer, flat M8
2• Nut, hex M6
1• Standoff proximity bracket
1• Standoff casing plate
1• Ring inlets
1• Door proximity bracket
2• Washer, M6
4• Rivets
1• Door alarm cable assembly
1471429ATalk Conversion Kit (EMIA):
Quan-tity
Product Code
Description
Talk Conversion Kit (EMIA)
Standoff casingplate
Standoffbracket
Doorproximitybracket
Upper lockrod support
(2 pcs)
Door alarmsensor wirh
wire
M8(4 pcs)
M5(16 pcs)
M3(4 pcs)
Connec-tion pins(4 pcs)
Flatwasher(4 pcs)
Startwasher(2 pcs)
M6 Nut(2 pcs)
Ring Inlet(1 pc)
Rivet(4 pcs)
Door switchparts
Front doorassembly Backwall
assembly
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 223/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
223
For internal use only
RA22714EN01GLA0223 © Nokia S iemens Ne tworks
Content of DeliveryTalk Conversion Kit (EMIB) (1/2)
1• Rack plinth
1• Rack side plate rightassembly
1• Rack side plate left
assembly
1• Door alarm cable assembly
2• Cover plate
2• Dummy Panel
1• Top support plate
• Cont’d ……..
1• Air guide plate
1• Top IP-cover
1• Front door assembly
1• Back wall assembly
1471953ATalk Conversion Kit (EMIB):
Quan-tity
Product Code
Description
Talk Conversion Kit (EMIB)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 224/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
224
For internal use only
RA22714EN01GLA0224 © Nokia S iemens Ne tworks
Content of DeliveryTalk Conversion Kit (EMIB) (2/2)
…. Cont’d
2• Upper lock rod supports
28• M5 x 10 TORX screws
1• Standoff proximity bracket
1• Top support C-plate
1• Rack plinth
2• Nut, hex M6
4• M4 x 10 screws
4• M3 x 6 TORX screws
1• Door proximity bracket
2• Grommet
40• Hole Nut
4• M8 x 16 screws
6• Cable tie
14• Support rail
Quan-tity
Product Code
Description
Talk Conversion Kit (EMIB) … cont’d
Door sensor assembly accessories bag (1pcs)
Door sensor assembly accessories bag (1pcs)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 225/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
225
For internal use only
RA22714EN01GLA0225 © Nokia S iemens Ne tworks
Content of DeliveryFlexi Mounting Auxiliary Bracket (FMAA)
471657AFlexi Mounting Auxiliary
Bracket (FMAA):
46151410• M4 x 10 screw
86150240• M5 x 10 screw
1822962• Bracket
46368770• M5 spring washer
46150275• M5 x 25 screw
86150343• M6 x 10 screw
Quan-tity
Product Code
Description
Flexi Mounting Auxiliary Bracket (FMAA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 226/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
226
For internal use only
RA22714EN01GLA0226 © Nokia S iemens Ne tworks
Content of DeliveryLMP cable delivery (ELCA), BBU Alarm Cable delivery (EBCA),Q1 cable delivery (EQCA), Flexi System Alarm Cable (FSAA)
1471370ALMP cable 50 m (164.0 ft), ELCA
Quan-tity
ProductCode
Description
LMP cable delivery (ELCA)
14717464BBU Alarm Cable Kit (EBCA) 2m (6.5 ft)
Quan-tity
ProductCode
Description
BBU Alarm Cable delivery (EBCA)
1471384AEQCA Q1 Cable 3.01 m (9.9 ft)
Quan-tity
ProductCode
Description
Q1 cable delivery (EQCA)
1471628AFlexi System Alarm Cable (FSAA):
D37 cable assembly 15 m (49.2 ft.)
Quan-tity
ProductCode
Description
Flexi System Alarm Cable (FSAA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 227/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
227
For internal use only
RA22714EN01GLA0227 © Nokia S iemens Ne tworks
Content of DeliverySynchronisation cable deliveries (ESxA)
1471372AESUA synchronisation cablefor Flexi Ultra 12 m (39.4 ft)
1471371AESFA synchronisation cablefor Flexi 12 m (39.4 ft)
1471377AESLA synchronisation LMUCable 2 m (6.6 ft)
Quan-tity
Product Code
Description
Synchronisation cable deliveries (ESxA)
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 228/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
228
For internal use only
RA22714EN01GLA0228 © Nokia S iemens Ne tworks
Flexi Multiradio BTS GSM/EDGEInstallation
Appendix - FSEB interface signals and connector pinassignments
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 229/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
229
For internal use only
RA22714EN01GLA0229 © Nokia S iemens Ne tworks
FSEB interface signals and connector pinassignments (1/5)
FSEB printed wiring board
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 230/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
230
For internal use only
RA22714EN01GLA0230 © Nokia S iemens Ne tworks
FSEB interface signals and connector pinassignments (2/5)
EACX connector I pin assignment EACX connector II pin assignment
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 231/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
231
For internal use only
RA22714EN01GLA0231 © Nokia S iemens Ne tworks
FSEB interface signals and connector pinassignments (3/5)
Screw terminal pin assignment EACX connector II pin assignment
1)The X connectors are marked on the bottom of the FSEB PCB.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 232/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
232
For internal use only
RA22714EN01GLA0232 © Nokia S iemens Ne tworks
FSEB interface signals and connector pinassignments (4/5)
Screw terminal pin assignment …cont’d Smoke detector power supply interface
1)The X connectors are marked on the bottom of the FSEB PCB.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 233/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
233
For internal use only
RA22714EN01GLA0233 © Nokia S iemens Ne tworks
FSEB interface signals and connector pinassignments (5/5)
Flexi System Alarm cable (FSAA) pin colour mapping
"CAN_L" and "CAN_H" refer to an internal busused between ESMB/C and FSEB.
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 234/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
234
For internal use only
RA22714EN01GLA0234 ©Nokia Siemens Networks
Flexi Multiradio BTS GSM/EDGEInstallation Planning
Appendix - Antenna Line
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 235/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
235
For internal use only
RA22714EN01GLA0235 ©Nokia Siemens Networks
Antenna LineAntenna jumper cable requirements
Antenna jumper cable requirements:
• 1/2" or 3/8" antenna jumper cables can be used. 1/2"antenna cable connectors can be connected directly to themodule if a right angle connector is used.
• The length should be determined based on the FlexiMultiradio BTS GSM/EDGE installation option (forexample pole, wall, cabinet, 3rd party cabinet) and thedistance of the BTS from the antenna feeder line.
• Antenna jumper cables must be IP54-rated or better.
Basically, Jumper cables are low–loss and flexible, which allows easier
connection to units such as the WCDMA MHA unit without causingunnecessary stress to the connected units (vs. feeder cables).
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation
http://slidepdf.com/reader/full/02-ra22714en01gla0-flexi-multiradio-installation 236/237
RA22714EN01GLA0
Flexi Multiradio BTS GSM/EDGE Installation
236
For internal use only
RA22714EN01GLA0236 ©Nokia S iemens Networks
Jumper cable
Feeder connector
Grounding kit
Feeder
Feeder clamp
Grounding kit
X-pol antenna
Antenna LineAntenna Line configurations with or without MHA
Jumper cable
Feeder connector
Grounding kit
Feeder
Feeder clamp
Grounding kit
Jumper cable
X-pol antenna
Jumper cable
MHA
Antenna Line configurationswithout MHA
Antenna Line configurationswith MHA
8/9/2019 02 RA22714EN01GLA0 Flexi Multiradio Installation