fitmate wm/gs/pro/med€¦ · • random video crash after modifying the anaerobic threshold...
TRANSCRIPT
1
July 2012 Software Update
Fitmate WM/GS/PRO/MEDSoftware & Firmware Upgrade 2.3
The present document shows major/minor improvements and bugs that have been fixed in the current release. Scroll below to see details for all past releases.
Fitmate Versions & Features
For a better understanding of all Fitmate versions please refer to the the table below:
TEST/PRODUCTS Fitmate WM
Fitmate GS
Fitmate Pro
Fitmate Med
Spirometry
Forced /Slow Vital Capacity (SVC-FVC) •
Maximum Voluntary Ventilation (MVV) •
Bronchial-Dilator test •
Cardio Pulmonary Exercise Testing
Cardio Respiratory Fitness (VO2 max, Sub-max VO
2) • •
Anaerobic Threshold (AT) • •
Indirect Cardiac Output (Wasserman) •
Heart rate with HR belt • •
12-lead Stress Test ECG option option
Integrated Pulse Oximeter (SpO2) option
Nutritional Assessment
Resting Energy Expenditure w/ mask • option • •
Resting Energy Expenditure w/ canopy hood option* • option* option*
Energy Balance • • • •
Physical Activity Monitoring Software • • • •
Diet Plans Software • • • •
Fitness Assessment
Body Composition (skin-fold) • • • •
Muscular Endurance/Strength •
Flexibility •
Standardized Measurement (WHR, BP, RHR, etc) • • • •
Exercise Prescription vs Training Zones
ACSM Exercise Prescription •
VO2/HR Training Zones • •
Exercise Intensity for Cardiac Rehabilitation •
Cardio Vascular Risk Analysis
Framingham Index PC only PC only PC only •
Duke Score •
Bode Index •
European Cardio Score •
Contents
1 Fitmate Versions & Features
2 News & Changes ver 2.3
3 News & Changes ver 2.2
4 News & Changes ver 2.0
5 How to Upgrade Fitmate
6 Upgrade Price Policy
Learn More
http://www.cosmed.com/fitmate
http://www.cosmed.com/fitmategs
http://www.cosmed.com/fitmatepro
http://www.cosmed.com/fitmatemed
http://www.cosmed.com/softwareupdates
Current Languages SW FW
Italian • •
English • •
Spanish • •
French • •
German • •
Portuguese • •
Greek • •
Dutch • •
Turkish •
Finnish • •
Polish •
Slovenian • •
Russian • •
Chinese • •
Korean • •
Japanese •
SW = Software FW = Firmware
* Fitmate Canopy Option is available to:
• allFitmateWMmodelsstartingfrom S/N 2009111000
• allFitmateMED/PROmodelsstart-ing from S/N 2009101000
2
News & Changes ver 2.3
Software 2.3• VisualC++RuntimeLibraryisnowenabledbydefaultintheinstallationpro-
gram
• NewFitmatemodeloption(FitmateGS)isavailableduringSWinstallation
• Newparameters(Gender,Height,RMRtestmode:canopyormask)havebeenadded in the header of exported *.txt file
• AnewversionofMacroExcelwillbeavailableintheDownloadareaofCOSMEDwebsite(http://www.cosmed.com/downloads).PreviousversionsofMac-roExcelarenotcompatiblewiththenew2.3Fitmatesoftware
• AGreekfooddatabasehasbeenaddedintheWeeklyDietPlannerSWfeature
• ParametersthatarenotenteredintheStandardMeasurementand/orMuscu-lar Fitness tests are neither printed nor visualized on the screen
Firmware 2.3• NewtestsectionhasbeenintroduceddedicatedtoRMRtestswithcanopy
hood(availableeitherforthenewFitmateGSmodelorforFitmatelinesys-tems*withthenewcanopyhoodoption).Seepicture1below.
• AdvancedOptionMenu:Ambientandflowmetertemperaturecannowbeadjusted
• Cardiorespiratoryfitnesstest:ManualselectionoftheRecoveryphaseincus-tom protocol has been improved
• Cardiorespiratoryfitnesstest:Ibramedbikeprotocolhasbeencorrectedanditworkscorrectly
• ParametersthatarenotenteredintheStandardMeasurementand/orMuscu-lar Fitness tests are no longer printed nor visualized on the screen
Settings of ambient and flowmeter temperature can now be adjusted in the Advanced option menu.
During installation of Fitmate software, Visual C++ Runtime Library is enabled by default among the components to be installed
Thermal printout of the RMR test using the canopy hood (Fitmate GS or with Fitmate Canopy Option*)
~ end of changes ver. 2.3 ~
1) Select Test Mode “Canopy” 2) Instructions on preparation for the RMR test with canopy
3) Execution of the test with canopy mode 4) Warnings during test execution (for example, O2 concentra-
tion is too high or too low)
5) Graphical results at the end of test 6) Final screenshot
3
Exercise phase highlighted in the Anaerobic Threshold dialog box
Fine tuning dialog box for Fitmate display
Possibility to put the leg stride value (cm or inches) during the accelerometer setup
New dialog box allows the generation of consistent PDF file names based on different criteria
New menu view with newly renamed Nutritional Assessment folder
News & Changes ver 2.2
Software 2.2• CompatibilitywithWindowsVistaandWin7operatingsystems(alsoat64bit)
• .xpofileimportnowworkswithallCOSMEDCPETsoftware(ver.9.1bandabove)
• UpdatedUSBdriverforWindows732/64bitcompatibility
• MisspellednameforActivityEnergyExpenditure(AEEvsAMR)corrected
• WarningmessageonEnergyBalanceprintout(ifweightlossis>1Kg/week,itcanbenowselected/deselectedbytheuserintheSetupmenu)
• SubjectDialogboxreducedtomatchlowerMonitorresolutionsorsmallerscreens.
• ExtrapolatedVO2max(duringSub-maxVO2)recalculatesincaseHRmaxischanged within the session
• IntheVO2maxtestsummaryergometerorprotocoltypenowvisualizedcor-rectly
• x-axisScaleofVO2maxgraphcorrected(nowmm:ss)
• Randomvideocrashaftermodifyingtheanaerobicthresholdcorrected
• Printpreviewinthe“notes”fieldintheSessionfoldernowworks
• Copy/pastebuttonaddedinthe“notes”fieldintheSessionfolder(readytousecustomforms)
• NewSetupsoftwareandNetworkconfiguration(noweasierandmoreuserfriendly)
• IntheAnaerobicThresholddialogboxtheExercisephaseishighlightedforbetterATdetection
• WeightManagementProgramfoldernowrenamedinNutritionalAssessment
• PersonalWeightManagementtestnowrenamedinEnergyBalance
• Addedthepossibilitytomanuallysetthelegstridelengthintheaccelerom-eter setup/initialization
• IntheMulti-weekActivityMonitorreporteachpageislabelledwiththenum-beroftheweek
• Auto-generationPDFreportingaccordingtoconsistentuserdefinedfilenames(ie.UserID_lastname_firstname*.pdf)
Firmware 2.2• CompatibilitywithHRbeltswithAnt+2.0technology
• FineDisplaytuning(backlightandcontrast)
• PhasealignmentinconsistentinsomeExercise/loadeventsduringVO2maxtests now corrected
• Duringsub-maxtest,BPandRPEcanbeinputevenafterthe“endofcriteria”.
• NewServiceMenunowpasswordprotected.
• BettergraphandATdisplayvisualizationfortestslongerthan20minutes
• FitmateMEDonly. VO2max Clinical report shows spirometry predicteds in casePreexercisespirometryhasnotbeenperformed(markedinthereport).
• “Leakdetection”messageimprovedwhentestingunderweightsubjects.
• Version2.2compatiblewithfuture“Fitmatecanopyoption”
4
New “Activity Monitor” Printout with data uploaded from physical activity monitor Fitmate Lifecorder (from ver. 2.0)
Food database screenshot (from ver. 2.0)
Activity Monitor settings screenshot (from ver.2.0)
New “Diet Plans” Report (from ver. 2.0)
Fitmate® Wellness Technology
Last Name: DEMO Age: 42 Membership #: 00001First Name: FITMATE Height (cm): 184,00 Report Date: 06/07/2008Gender: Male Weight (Kg): 69,3 Personal Trainer:
FitMate version 2.0 (build 20) Page 1 of 1These statements are not intended to be used to diagnose, treat, cure or prevent any disease. Consult your physician before starting any weight-loss or fitness program.
Activity MonitorDays:
Partial Days:Recorded Period:Selected Period:
Selected Days:
656 (marked as *)06/04/2009 - 09/06/200928/05/2009 - 03/06/20097
Total Energy Expenditure (Kcal)Activity Time (min)Activity Energy Expenditure (Kcal)Steps (#)Distance (km)Intensity Level Very Light (hh:mm)Intensity Level Light (hh:mm)Intensity Level Moderate (hh:mm)Intensity Level Heavy (hh:mm)Functional Capacity (METS)
Daily Avg211817313101957,812.4300.2400.0300.021,9
Daily Target
30350
Total
125
7137054,589.0402.5400.2100.17
Total Energy Expenditure (Kcal)Daily Avg2119
2047 2303 2139 2230 2175 1995 1941
Activity Energy Expenditure (Kcal)Daily Avg314
242
498334
425 370190 136
Activity time (min)latoTgvA yliaD
12418
1728
8
38
20
7 6
StepslatoTgvA yliaD
7137010196
8094
1550612041 13213
11250
66094657
Distance (km)latoTgvA yliaD
54,57,8
6,3
11,88,9 10,3
8,75,0 3,5
Intensity Level Very Light (hh:mm) <3 METSlatoTgvA yliaD
89.0412.4312.28 11.21 13.54 12.59 11.21 14.34 12.25
Intensity Level Light (hh:mm) 3-4 METSlatoTgvA yliaD
02.5400.24
00.23 00.3500.16
00.45 00.28 00.13 00.11
Intensity Level Moderate (hh:mm) 5 METSlatoTgvA yliaD
00.2100.03
00.03 00.03 00.01 00.08 00.02 00.01 00.01
Intensity Level Heavy (hh:mm) >5 METSlatoTgvA yliaD
00.1700.02
00.00 00.07 00.00 00.01 00.06 00.00 00.00
Average METSDaily Avg1,9
2,0 2,11,5
2,3 2,1 1,7 1,8
Daily Energy Expenditure (Average)2118 Kcal
RMR 1805
85%
AEE 313
15%
thu fri sat sun mon tue wed thu fri sat sun mon tue wed thu fri sat sun mon tue wed
thu fri sat sun mon tue wed thu fri sat sun mon tue wed thu fri sat sun mon tue wed
thu fri sat sun mon tue wed thu fri sat sun mon tue wed thu fri sat sun mon tue wed
thu fri sat sun mon tue wed
News & Changes ver 2.0
Software• IntegrationwithFitmateLifecorderaccelerometer:physicalactivitydatacan
bedownloadedviaUSBinterfaceandautomaticallyintegratedwithRMRmeasurement.LifecordercanbeprogrammeddirectlythroughFitmatesoft-waretosetgoals,lockfromtheuser,hide/showresults,etc.
• NewimplementationoftheDietPlanssectionwithadetailedandcustom-isablefooddatabase,basedontheUnitedStatesDailyAllowance(USDA)pyramid.
• New“Elite”TrainingZones
• HealthySubjectreport(FitmateMEDonly)
• NewIconsset
Hardware Enhancements• Customprotocolforbike/treadmill
• RMRgraphnowprintedafterRMRtesting(userdefined)
• %ofVariationforVEandVO2duringtest(qualitycontrol)
• Automatic/Manualdetectionofsteady-stateRMRinterval
• New“Elite”trainingzones
Bugs Fixed• ImprovedmanagementofANTdevices(HRmonitor)
• DefaultvalueofATisnowontheVE/VO2minimum(beforeitwascentral)
• AdjustedthegraphoftheMVVlineontheclinicalreportofFitmateMED
• Duringin/lbmodeitisnowpossibletoinsertheightininchesequaltozero
• Inthespirometryreport(FitmateMED)itisnowshowntheFEV1/VC%value
• Solvedsomeissuesrelatedtotheresultsclassification(rangeandrank)
• ImprovedtheuploadofXPOfiles
5
Improved RMR Thermal Printout with graphical representation of RMR measurement (from ver. 2.0)
Improved Cardio Respiratory Fitness (CRF) Thermal Printout with 6 Training Zones (Fitmate PRO only) (from ver. 2.0)
Reports UpdateReportingisbeingcontinuouslyenhancedwithnewFirmwareandSoftware.Herefollows a matrix on reports from Fitmate product line:
Report Fitmate Fitmate PRO Fitmate MED
A4 P
rinto
uts
Session Summary • • •
Alternate Summary • • •
Trends • • •
Goal • •
Energy Balance • • •
Diet Plan 2.0 2.0 2.0
Activity Monitor 2.0 2.0 2.0
Body Composition • • •
Standard Measurements • • •
Cardio Respiratory Fitness Updated (2.0) 2.0
Cardio Respiratory Fitness (Clinical) •
Muscular Fitness •
Flexibility •
Exercise Prescription •
Cardio Vascular Risk Factors •
Spirometry •
Ther
mal
Prin
tout
s
Resting Metabolic Rate Updated (2.0) Updated (2.0) Updated (2.0)
Nutrition Assessment • • •
Body Composition • • •
Standard Measurements • • •
Cardio Pulmonary Exercise Test •
Cardio Respiratory Fitness - VO2max Updated (2.0) Updated (2.0)
Cardio Respiratory Fitness - Sub-max • •
Caloric Cost •
Fitness Assessment •
Cardio Vascular Risk Factors •
Spirometry •
SpO2 •
MoredetailedoverviewofExerciseTestingreports(onlyFitmatePRO&FitmateMED):
Printouts Fitmate MED Fitmate PRO
Report type Fitness/Sport Clinical Fitness/Sport
Sub
max
imal
Anaerobic Threshold na na na
Graphs VO2Kg vs. HR VO
2Kg vs. HR VO
2Kg vs. HR
Training Zones Health/Fitness Cardiac Rehab Health/Fitness
VO2max Interpretation ACSM AHA Classification ACSM
Predicteds na na na
PC Report • (NEW) • •
Max
imal
Anaerobic Threshold • • •
Graphs VO2Kg & HR vs. time VO
2Kg & HR vs. time
VE & VO2/HR vs. time
VO2Kg & HR vs.
time
Training Zones
w/ AT Healthy/Athlete AHA Rehab Healthy/Athlete
w/o AT Healthy/Fitness AHA Rehab Health/Fitness
VO2max Interpretation ACSM AHA Classification ACSM
Predicteds ACSM Jones/Wasserman ACSM
PC Reports • (NEW) • •
Legend - na: not available | ACSM; American College of Sports Medicine | AHA; American Heart Association
6
How to Upgrade Fitmate
Importantreadcarefullybeforeupgradingtheunit.Becauseofchangesinthestructureofthedatabase,archiveshavetobeconvertedduringtheupgrading.Beforeupgrading,alltestsstoredintheFitmateunitMUSTBEdownloadtothePCotherwise all data in the Fitmate unit will be lost!
To install upgrade follow instructions below.
Upgrade Software Fitmate to ver. 2.31. DownloadallthedatayouhaveonyourFitmateunittothePCSW.
2. DoabackupcopyoftheSWarchives,onceyoucompleted,proceedwiththeSWupgrade.
3. RemovethepreviousversionofFitmatebyusingtheWindowsfunctionincontrolpanel(Add/RemovePrograms).
4. Duringthisprocess,Windowswillaskifyouwanttoremovethelocalarchiveof Fitmate. Select NOtokeepexistingdatabase.InthiscasethenewSoftwaremusttobeinstalledinthesamepathwherethepreviouswaslocated(defaultpathis:C:\ProgramFiles\COSMED\Fitmate).
5. InserttheCDwiththenewFitmateversionandselect“InstallFitmateSoft-ware”…followtheinstructionstocompletetheinstallation
a)Select“InstallFitmateSoftware”
b)(Windows7only)Ifyoudidn’tloginasAdministrator,entertheAdministrator’spassword
c)Selecttheinstallationlanguage.Thesoft-ware language can be chosen later
d)Confirmthecomponentstobeinstalled(automaticallyselectedbythesoftware)
e)Confirmorselectadifferentinstallationfolder
7
Press this button to upload/change language in the Fitmate
f )Selectthearchivefolder
g)InstallifneededtheUSBdrivers
h)Thesoftwareisnowinstalled
Oncetheinstallationprocedurewillbefinished,theauthorizationmaskwillbeprompted.
Upgrade Firmware to ver. 2.31. Aftersoftwareinstallationiscompleted,connectyourFitmateunittothePC
(usingtheUSBcable),switchFitmateONandwaitfortheUSBdriverinstalla-tion.
2. Press ChangeFitmateLanguage... if you want to up-load a different language amongthoseavailable.Defaultpre-installedlanguageisEnglish.
3. Select NextontheSoftwareAuthorizationwindow.
4. Awarningmessagewillbeshown,thefirmwareisabouttobeupgradedandall data inside the unit will be lost.
5. Press Yestostartupgrading.Astatusbarwilldisplaytheprogress(ittakesabout6-8minutes).
6. Whenupgradingiscompletedtheunitwillbeautomaticallyactivated.
Upgrade Price Policy
Fitmate suite 2.3 is a free-of-charge upgrade for all registered users with Fitmate ver2.x.SpecialupgradepricesareavailableforallotherexistingFitmateusers,contact sales department for details about those offers.
WehopenewfeatureswillhelpingettingmoreresultsfromyourFitmateandsatisfynewrequirements.
For any additional information please contact [email protected]
Sincerely
MarcoBrugnoli
ManagingDirector