fiber optic temperature sensing solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • usb,...
TRANSCRIPT
![Page 1: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/1.jpg)
1OSENSA Innovations Corp. 1m
OSENSA Innovations Corp. 11
Fiber Optic Temperature Sensing Solutions
Find us at www.osensa.com
![Page 2: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/2.jpg)
2OSENSA Innovations Corp. 2m
OSENSA Innovations Corp.
Fiber Optic Probes are Immune to EMI
![Page 3: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/3.jpg)
3OSENSA Innovations Corp. 3m
OSENSA Innovations Corp.
Fiber Optic Probes are Immune to EMI
![Page 4: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/4.jpg)
3OSENSA Innovations Corp. 3m
OSENSA Innovations Corp.
Fiber Optic Probes are Non-Conducting
![Page 5: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/5.jpg)
5OSENSA Innovations Corp. 5m
OSENSA Innovations Corp.
Fiber Optics Versus Infrared
Fiber Optics Infrared
![Page 6: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/6.jpg)
6OSENSA Innovations Corp. 6m
OSENSA Innovations Corp.
![Page 7: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/7.jpg)
7OSENSA Innovations Corp. 7m
OSENSA Innovations Corp.
![Page 8: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/8.jpg)
8OSENSA Innovations Corp. 8m
OSENSA Innovations Corp.
NEW Products 2018
1 to 18 Channels Touch Display Ethernet, USB, RS232
Low Cost Transformer Temperature Monitoring
![Page 9: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/9.jpg)
9OSENSA Innovations Corp. 9m
OSENSA Innovations Corp.
OSENSA ProductsFTX-301-PWR+, FTX-602-PWR+Applications: Bus Bars, Generators, Motors & Switch Gear• 3 or 6 channels• USB, RS485• 4-20mA Output• Low cost Polymer Probes or 200°C Glass bundle probes
FTX-101-OEMApplications: OEM Solutions• Serial UART or SPI• 200, 400 & 1000 micron fiber Probes• High Accuracy & Stability• Low Cost, High Volume OEM Applications• Fast Response time
FTX-301-XFMR+, FTX-602-XFMR+Application: High Voltage Transformers• 3 or 6 Channels• USB, RS485• 4-20mA Output• Lumasense LuxtronTM Compatible• 200 micron fiber Probes• Fiber Feed-Thru
FTX-300-LUX+Applications: Medical & Research• 1 to 3 channels• High Accuracy & Stability
• 200 & 400 micron fiber Probes
![Page 10: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/10.jpg)
10OSENSA Innovations Corp. 10m
OSENSA Innovations Corp.
Field Installations
Switchgear Bus Bar
temperature monitoring
Using OSENSA’s GB3 Fiber Optics
TemperatureProbes
![Page 11: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/11.jpg)
11OSENSA Innovations Corp. 11m
OSENSA Innovations Corp.
Field Installations
Using OSENSA’s GB3 Fiber OpticsTemperatureProbes
Bear Swamp Hydroelectric
Generation Station Circuit Ring Fiber Optics
Temperature Probe Installation
![Page 12: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/12.jpg)
12OSENSA Innovations Corp. 12m
OSENSA Innovations Corp.
Field Installations
![Page 13: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/13.jpg)
13OSENSA Innovations Corp. 13m
OSENSA Innovations Corp.
Field Installations
9000 HPThree-Phase Induction Motor
Using OSENSA’s GB3 Fiber OpticsTemperatureProbes
![Page 14: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/14.jpg)
14OSENSA Innovations Corp. 14m
OSENSA Innovations Corp.
Field Installations
Using OSENSA’s GB3 Fiber OpticsTemperatureProbes
Motor’s Stator Winding
![Page 15: Fiber Optic Temperature Sensing Solutions 2018... · 2018. 4. 25. · • 3 or 6 channels • USB, RS485 • 4-20mA Output • Low cost Polymer Probes or 200°C Glass bundle probes](https://reader035.vdocuments.site/reader035/viewer/2022071112/5fe7e08571960123b454f888/html5/thumbnails/15.jpg)
15OSENSA Innovations Corp. 15m
OSENSA Innovations Corp.
Field Installations
China’s Three Gorges Damgenerator
Using OSENSA’s GB3 Fiber OpticsTemperatureProbes