fiber monitor panel, fmp series

2
Fiber Monitor Panel, FMP series Fiber Interface Panel for Macro and DAS diagnostics Rev. B t Up to 12 channel pairs in 1 RU t Permanent monitor/sample port Never have to break a link t Easy access to monitor port on opposite side of signal inputs t Reliable all passive technology ensures maximum up-time t Rack ears accommodate both 19” & 23” racks t User defined number of channels, coupler values, connector types, and fiber mode Table 1 - Optical Specifications Features The FMP series Fiber Monitor Panel offers a monitor port for both analog (RFoF) and digital (CPRI) fiber links. It enables connection to a test and monitoring tool without the need to disrupt an installation. With the advent of Common Public Radio Interface (CPRI) and Open Base Station Architecture Initiative (OBSAI) various devices are be- ing introduced to determine the health of a digital fiber interface. A problem can arise if the troubleshooting needs to be done outside of the maintenance window, or if the symptom disappears on signal reset. To resolve those problems the FMP was developed. The unit installs in the equipment rack either when the system is being built out, or during a maintenance window. The impact on the fiber infrastructure is minimal as only a portion of the optical energy is diverted. An RFoF, CPRI, or OBSAI analyzer can then be connected to one of the sampled ports. Description Parameter Unit Specification Operating Wavelength nm 1310 and 1550 Operating Bandwidth nm ± 40 Coupling Ratio (through/coupled) % 50/50 90/10 80/20 Max. Insertion Loss (through/coupled) dB 3.7/3.7 0.7/11.8 1.5/8.0 Max. PDL 0.1 0.2/0.1 0.15/0.1 Directivity dB >55 Return Loss dB >50 Operating Temperature °C 0 to +70 Storage Temperature °C -40 to +85 Reliability, Compliance Telcordia GR-1221-Core Part Numbering Guide Table 2 - Mechanical Specifications Parameter Unit Specification Dimensions without ears (W x D x H) mm 422 x 200 x 43.80 in 16.614 x 7.874 x 1.724 Max. Weight lb 3 Note: Specifications are subject to change without prior notification. Microlab, A Wireless Telecom Group Company, 25 Eastmans Road, Parsippany, NJ 07054 Tel: (973) 386-9696 • [email protected] • www.microlab.fxr.com • Fax: (973) 386-9191 14MAR2016 FMP XX YYYY Z N Fiber Monitor Panel # of Channel Pairs 06 = 6 channel pairs 12 = 12 channel pairs Coupling Value 5050 = 50%/50% 8020 = 80%/20% 9010 = 90%/10% Fiber Mode S = Single Mode M = Multi-mode Fiber Endface Polish A = APC, 8 deg angled physical contact (green) U = UPC, ultra physical contact dome (blue) -

Upload: others

Post on 22-Mar-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Fiber Monitor Panel, FMP seriesFiber Interface Panel for Macro and DAS diagnostics

Rev. B

t Up to 12 channel pairs in 1 RU

t Permanent monitor/sample port

Never have to break a link

t Easy access to monitor port on opposite

side of signal inputs

t Reliable all passive technology ensures

maximum up-time

t Rack ears accommodate both 19” & 23” racks

t User defined number of channels, coupler

values, connector types, and fiber mode

Table 1 - Optical SpecificationsFeatures

The FMP series Fiber Monitor Panel offers a monitor port for both analog (RFoF) and digital (CPRI) fiber links. It enables connection to a test and monitoring tool without the need to disrupt an installation. With the advent of Common Public Radio Interface (CPRI) and Open Base Station Architecture Initiative (OBSAI) various devices are be-ing introduced to determine the health of a digital fiber interface. A problem can arise if the troubleshooting needs to be done outside of the maintenance window, or if the symptom disappears on signal reset. To resolve those problems the FMP was developed. The unit installs in the equipment rack either when the system is being built out, or during a maintenance window. The impact on the fiber infrastructure is minimal as only a portion of the optical energy is diverted. An RFoF, CPRI, or OBSAI analyzer can then be connected to one of the sampled ports.

Description

Parameter Unit Specification

Operating Wavelength nm 1310 and 1550

Operating Bandwidth nm ± 40

Coupling Ratio(through/coupled)

% 50/50 90/10 80/20

Max. Insertion Loss(through/coupled)

dB 3.7/3.7 0.7/11.8 1.5/8.0

Max. PDL 0.1 0.2/0.1 0.15/0.1

Directivity dB >55

Return Loss dB >50

Operating Temperature °C 0 to +70

Storage Temperature °C -40 to +85

Reliability, Compliance Telcordia GR-1221-Core

Part Numbering Guide

Table 2 - Mechanical Specifications

Parameter Unit Specification

Dimensions without ears(W x D x H)

mm 422 x 200 x 43.80

in 16.614 x 7.874 x 1.724

Max. Weight lb 3

Note: Specifications are subject to change without prior notification.

Microlab, A Wireless Telecom Group Company, 25 Eastmans Road, Parsippany, NJ 07054

Tel: (973) 386-9696 • [email protected] • www.microlab.fxr.com • Fax: (973) 386-9191

14MAR2016

FMP XX YYYY Z N

FiberMonitor

Panel

# of Channel Pairs06 = 6 channel pairs12 = 12 channel pairs

Coupling Value5050 = 50%/50%8020 = 80%/20%9010 = 90%/10%

Fiber ModeS = Single ModeM = Multi-mode

Fiber Endface PolishA = APC, 8 deg angled physical contact (green)U = UPC, ultra physical contact dome (blue)

-

Figure 2 - FMP Outline

Fiber Monitor Panel, FMP seriesFiber Interface Panel for Macro and DAS diagnostics

Page 2

Microlab, A Wireless Telecom Group Company, 25 Eastmans Road, Parsippany, NJ 07054

Tel: (973) 386-9696 • [email protected] • www.microlab.fxr.com • Fax: (973) 386-9191

Dimensions in mm

Figure 1 - Electrical Diagram (Side A only, Duplicated for Side B)