faira transparency reports 4625 highland dr, bellevue, … · • recommend following conditions...
TRANSCRIPT
608 State St. South Kirkland, WA 98033
www.faira.com
[email protected] +1.800.571.FAIR
FAIRA TRANSPARENCY REPORTS
4625 Highland Dr, Bellevue, WA 98006
Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.
You may view more detailed information for this home and can make an offer at
http://www.faira.com/listings/11955 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team
RW West Consultants, Inc.Property Inspection Report
Cover Page
4625 Highland Dr, Bellevue, WAInspection prepared for: Faira .com
Real Estate Agent: -
Date of Inspection: 4/11/2018 Time: 11:00 AM Age of Home: 1978 Size: 3740
Order ID: 3586
Inspector: Robert PickeringLicense #1807
Email: [email protected]
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 1 of 74
General Exterior Note 1. Exterior Note
||2||East Elevation ||2||South Elevation
||2||North Elevation ||2||West Elevation
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 2 of 74
Exterior Areas 1. Siding ConditionSiding appeared in good condition overall. • Wood siding.Observations:• Paint flaking at the siding, recommend loose paint is removed, barewood areas primed andrepainted.• Dryer vent cover stays in the open position, normally should only open when dryer is in operation.Recommend conditions are corrected to prevent animal entry and air infiltration.• Foundation cracks do not appear unusual• Foundation form wires protruding around foundation. These ends can cause injury. Recommendbending over or removal, minor condition to correct.
East right of garage
North
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 3 of 74
2. GuttersGutters and downspouts appeared in good condition overall.
3. Driveway and Walkway ConditionConcrete sidewalks and driveways appeared in good condition overall.Observations:• Cracking at the driveway/sidewalk does not appear unusual.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 4 of 74
4. SoffitSoffits and eaves appeared in good condition overall.
5. GradingGrading appeared in good condition overall.Observations:• Grade slopes toward the house from east to west.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 5 of 74
6. ElectricalExterior outlets operate overall • Exterior outlets are GFCI protected overallObservations:• No power to outlet, recommend further investigation and correction.• Outlet fixture improperly size for box, strongly recommend conditions are investigated further andcorrected as required by licensed electrical contractor.
At deck near family room did not operate7. Cable FeedsMaterials: Primary Service is Underground Service Lateral
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 6 of 74
8. Gas ConditionMeter located at South side. Main Gas shutoff is located to the lower left of the meter.
9. Exterior Faucet ConditionExterior faucets were in operable condition overall.Observations:• Hose bib at east side of house leaks.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 7 of 74
10. Pressure85
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 8 of 74
Deck 1 1. Deck1West
2. DeckDecking and Visible framing appeared in good condition overall. • Guardrail appeared secure. •Handrail appeared secure. • Deck surface covered with water proof coatingObservations:• Voids in sealant at top rail. Recommend sealing.• Ledger board secures deck to the house with nails instead of lag bolts. Nails loosen withtemperature/moisture and humidity changes and can result in deck collapsing. Stronglyrecommend lag bolts are installed as a safety precaution.• Handrail not graspable. By today's standards, rails should be configured so that a hand maygrasp around a rail for safety.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 9 of 74
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 10 of 74
Exterior Stairs 1. StairSteps appeared uniform. • Handrail appeared secure.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 11 of 74
Roof 1. Roof ConditionArchitectural Composition shingle.Type Average life span 30 years for this type surface with proper maintenance and care.Observations:• Trace amount of Moss on roof. Recommend treating moss with a moss retarding chemical.Pressure washing is not recommended as it can damage surface and lessen life span.• Recommend following conditions are investigated further by licensed roofing contractor.• Some granular surfacing deteriorated. Recommend further investigation by licensed roofingcontractor
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 12 of 74
2. FlashingFlashing appeared in good condition overall.Observations:• Flashing lifting at south chimney, recommend additionally securing.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 13 of 74
3. SkylightsSkylights appeared sealed, no visible indications of leakage.
4. Spark Arrestor
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 14 of 74
5. Vent CapsObservations:• Recommend additionally securing vent caps west side
6. ChimneyBrick masonry Chimney • Metal Chimney with wood enclosureObservations:• Brick and mortar deterioration observed; recommend conditions are repaired by licensed chimneysweep or masonry contractor.• Cracking in the crown of the chimney, recommend resealing.• Ponding on chimney crown northwest side. Recommend monitoring
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 15 of 74
South
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 16 of 74
Attic 1 1. AtticGarage is location of access.
2. FramingFraming appeared in good condition overall. There were no visible indications of decay.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 17 of 74
3. VentilationVentilation appeared adequate overall. • Under eave soffit inlet vents noted. • Roof surface ventspresent. • Gable louver vents noted.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 18 of 74
4. ElectricalObservations:• Wire ends are outside of a Junction Box, which is a potential shock hazard, recommend junctionboxes with covers be installed by licensed electrical contractor
Left of entry Right of entry north5. Insulation ConditionRock wool fiberglass insulation present.Depth: Insulation averages approximately 10-12 inches in depth, estimated R value 30
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 19 of 74
Attic 2 1. AtticMaster bedroom closet is location of access.
2. FramingVisible framing appeared in good condition overall, no visible indications of decay or waterpenetration presently.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 20 of 74
3. VentilationVentilation appeared adequate overall. • Under eave soffit inlet vents noted. • Roof surface ventspresent. • Gable louver vents noted.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 21 of 74
4. Fan/DuctObservations:• Bathroom fans do not exhaust completely to the exterior. Typically piping should actually connectto exterior vent, recommend correction. This condition can result in mold/fungal growth.• Furnace exhaust vent decayed recommend further investigation by a licensed HVAC contractor.
Furnace vent Furnace vent
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 22 of 74
Furnace vent5. ElectricalObservations:• Wire nutted electrical connections not in junction boxes, is a potential shock hazard.Recommend installing cover plates
South near hall bathroom
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 23 of 74
6. Insulation ConditionRock wool fiberglass insulation present.
7. Rodent/PestsNo visible indications of Rodent Activity.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 24 of 74
General Interior Note 1. General NotesMaterials: Windows in the home are Double pane insulated glass windows. Any deficiencies arenoted in each room section for accessible windows • Doors in the home are considered operationalunless otherwise noted in each room section • Cabinet doors and in the home are consideredoperational unless otherwise noted in each room section
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 25 of 74
Entryway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. Entry door operates andlocks overall. • Laminate wood grain material is in good condition overall. • Windows are thermalpane, appeared sealed overall • Heat register operates overall. • Accessible outlets operate.
2. ElectricalObservations:• Ungrounded outlets, recommend a licensed electrical contractor investigate conditions further andcorrect as required.
3. FloorObservations:• Wood floor finish sun bleached.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 26 of 74
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 27 of 74
Living Room 1. Living RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.
2. ElectricalMaterials: Top halves of outlet on the west wall switch controlled.
3. FireplaceFireplace is a gas unit. • Damper is in place.Observations:• Gas Shutoff is located inside access panel under glass.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 28 of 74
Kitchen 1. Kitchen RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate. Light fixture operates. Sink and faucets are in operable conditionoverall. Cabinet doors and drawers are in operable condition overall.Cabinet doors and drawers are in operable condition overall.
2. Counter ConditionGranite counter tops are in good condition.
3. CabinetCabinet doors and drawers are in operable condition overall.
4. DisposalDisposal operates overall.
5. DishwasherDishwasher was in operable condition.
6. MicrowaveObservations:• Built-in microwave ovens are tested using normal operating controls. Unit was tested andappeared to be serviceable at time of inspection. Leak and/or efficiency testing is beyond the scopeof this inspection. If concerned, client should seek further review by qualified technician prior toclosing.
7. FloorObservations:• Wood floor finish sun bleached.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 29 of 74
8. Stove/OvenCook top was in operable condition overall. • Oven was in operable condition overall.
9. RefrigeratorRefrigerator was in operable condition.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 30 of 74
10. SinksSink was in operable condition overall.
11. ElectricalOutlets are GFI protected with exception of outlets for refrigerator, disposal and microwave.Observations:• Outlet and or Switch cover plates missing, recommend correction as a safety precaution.
Underneath Cabinets12. Vent ConditionVent fan appears to exhaust to the exterior.
13. HeatingHeat register operates.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 31 of 74
Family Room 1. LocationLocation South
2. Family RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate. • Light fixture operates.
3. FloorObservations:• Wood floor finish sun bleached.
4. FireplaceFireplace is a gas unit.Observations:• Gas shutoff is located at the wall adjacent to the fireplace.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 32 of 74
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 33 of 74
Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Accessible outlets operate.• Wood flooring in good condition overall
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 34 of 74
Master Bedroom 1. LocationLocation 1st Left
2. BedroomWalls and ceilings appear in good condition overall. Flooring is carpet in good condition. Heatregister present. Accessible outlets operate. • Windows are thermal pane. • Light fixture operates.
3. ElectricalObservations:• West wall outlet has lost it’s integrity, strongly recommend further investigation and correction bylicensed electrical contractor.
4. HeatingHeat register operates.
5. Window DeficienciesObservations:• Discoloration/condensation between the panes. This is an indication of a failed seal. Recommendconditions are corrected by licensed glass company.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 35 of 74
6. Ceiling FanMaterials: Ceiling Fan was in operable condition overall
7. DoorsObservations:• Entry door sticks, recommend adjustment.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 36 of 74
Master Bathroom 1. LocationMaterials: 1st Floor • Bedroom
2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. •There were no visible indications of plumbing deficiencies overall.
3. ElectricalGFI outlets within 6 feet of the water sources.Observations:• North wall Outlet is not GFCI protected. Strongly recommend conditions are investigated furtherand corrected by licensed electrical contractor as a safety precaution.
4. CountersGranite counter tops are in good condition.
5. CabinetsCabinet doors and drawers are in operable condition overall.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 37 of 74
6. SinksSink was in operable condition overall.Observations:• Overflows at sink did not operate. Recommend conditions are corrected.
7. Exhaust FansVent fan operates overall.
8. FloorsTile Flooring is in good condition overall. • Carpet floor covering is in good condition.
9. ShowerShower is in good condition overall. • Shower door is in operable condition overall.Observations:• Shower grout absorbs moisture when water comes in contact, recommend sealing shower grout.• Voids in the grout between some of the tile, recommend resealing.
10. ToiletToilet was in operable condition overall.
11. HeatingHeat register operates.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 38 of 74
Hall Bathroom1 1. LocationMaterials: 1st Floor
2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. •There were no visible indications of plumbing deficiencies overall.
3. CountersGranite counter tops are in good condition.
4. CabinetsCabinet doors and drawers are in operable condition overall.
5. Exhaust FansVent fan operates overall.
6. FloorsTile Flooring is in good condition overall.
7. TubTub and shower were in good condition overall.
8. SinksSink was in operable condition overall.
9. ToiletToilet was in operable condition overall.
10. HeatingObservations:• There is no heat source in this room.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 39 of 74
11. DoorsObservations:• Entry door sticks, recommend adjustment.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 40 of 74
Bedroom 1 1. LocationLocation 1st Right
2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.
3. ElectricalObservations:• Reversed polarity at west and south wall outlets, recommend a licensed electrical contractorinvestigate conditions further and correct as required.
4. HeatingHeat register operates.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 41 of 74
Bedroom 2 1. LocationLocation 2nd Right
2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.
3. HeatingHeat register operates.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 42 of 74
Stairs Leading to Basement 1. StairSteps appeared uniform. • Handrail appeared secure.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 43 of 74
Basement Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates.
2. DoorsObservations:• Closet door are missing bottom guides, recommend installing.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 44 of 74
Basement Family Room 1. Family RoomWalls and ceilings appear in good condition overall. Flooring is wood in good condition. Heatregister present. Accessible outlets operate. • Windows are thermal pane. • Light fixture operates. •Sliding glass door operates overall.Observations:• Staining at the ceiling, moisture meter indicated no abnormal moisture content presently.
2. ElectricalObservations:• Reversed polarity at south wall outlet, recommend a licensed electrical contractor investigateconditions further and correct as required.
3. Floor
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 45 of 74
4. FireplaceFireplace is a gas unit.Observations:• Gas shutoff is located at the wall adjacent to the fireplace.• Pilot Controls are located inside access panel under glass.
5. Counter ConditionFormica counter is in good condition overall.Observations:• Voids in the counter at the back splash, recommend resealing.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 46 of 74
6. Stove/OvenCook top was in operable condition overall.
7. DoorsObservations:• Sliding glass door difficult to operate, recommend adjustment
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 47 of 74
Basement Bathroom 1. LocationMaterials: Basement Hallway
2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. •There were no visible indications of plumbing deficiencies overall.
3. ElectricalGFI outlets within 6 feet of water sources.
4. CountersGranite counter tops are in good condition.Observations:• Voids in the caulking at the back splash, recommend sealing.
5. CabinetsCabinet doors and drawers are in operable condition overall.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 48 of 74
6. Exhaust FansVent fan operates overall.
7. FloorsTile Flooring is in good condition overall.
8. TubTub and shower were in good condition overall.
9. ShowerObservations:• Voids in the grout between some of the tile, recommend resealing.
10. SinksSink was in operable condition overall.
11. ToiletToilet was in operable condition overall.
12. HeatingHeat register operates.
13. WindowsObservations:• Tempered glass stamps not visible on the windows. Normally windows in this location should betempered glass in case one slips and has to brace themselves on the glass. recommend conditionsare investigated further and corrected by licensed glass contractor.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 49 of 74
Tempered glass stamps not visible on the windows. Normally windows in this location should betempered glass in case one slips and has to brace themselves on the glass. recommend conditions
are investigated further and corrected by licensed glass contractor.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 50 of 74
Basement Bedroom 1 1. LocationLocation South
2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.
3. HeatingHeat register operates.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 51 of 74
Basement Bedroom 2 1. LocationLocation Southwest
2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is carpet. Heat register present.Accessible outlets operate. • Light fixture operates.
3. HeatingHeat register operates.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 52 of 74
Basement Laundry Room 1. LocationBasement
2. ConditionCeiling and walls are in good condition overall. Accessible outlets operate. • Light fixture operates. •No machines installed in home at time of inspection.
3. CabinetCabinet doors are in operable condition overall.
4. ElectricalObservations:• GFCI outlets have been required for Laundry and utility sinks (since 2005)No GFCI protectionpresent,, strongly recommend GFCI outlets are installed as a safety precaution.• No GFCI protection present,, strongly recommend GFCI outlets are installed as a safetyprecaution.
5. Exhaust FansVent fan operates overall.
6. DryerThere is a place for dryer to exhaust to the exterior. • 220 volt electrical service for electric dryer.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 53 of 74
7. Floor ConditionLaminate wood grain material is in good condition overall.
8. SinkSink is in operable condition overall.
9. HeatingHeat register operates.
10. WasherObservations:• Right hose bib leaks, recommend repair
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 54 of 74
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 55 of 74
Utility Room 1. Utility RoomWalls and ceilings appear in good condition overall. Flooring is concrete in good condition.Accessible outlets operate.
2. ElectricalObservations:• Outlet cover plates missing, recommend cover plates are installed.
3. FloorObservations:• Cracking to the concrete floor does not appear unusual.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 56 of 74
4. Window DeficienciesObservations:• Indication of moisture intrusion at some point. Recommend monitoring.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 57 of 74
Garage 1. ConditionWalls and ceilings appeared in good condition overall. Accessible outlets operate. Light fixturesoperate overall. Flooring is concrete, visible portions in good condition overall. • Wood frame wallsappeared in good condition overall.Observations:• Indications of past leaking dry at time of inspection, recommend further investigation
2. Floor ConditionMaterials: Flooring is concrete, appeared in good condition overall.Observations:• Cracking at the floor does not appear unusual.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 58 of 74
3. ElectricalObservations:• Improper use of extension cord observed. Extension cords should not be permanently installed orbe routed through walls, floors or partitions.• Outlet did not operate, recommend further investigation.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 59 of 74
Did not operate4. DoorsEntry door is in operable condition overall.
5. Garage DoorsDouble garage door was in operable condition, was on auto opener. • Photo cell safety returnsoperate overall. • Tension safety returns operate overall.
6. StairSteps appeared uniform. • Handrail appeared secure.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 60 of 74
Heat/AC 1. Heating TypeGas forced air furnace.
2. Heater Location Furnace is located in the utility roomFurnace is Bryant Brand. • 18 years of age approximately, average life span is 18 to 22 years.
3. Heating conditionObservations:• Service does not appear to have been performed within the last year, recommend serviced bylicensed HVAC contractor.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 61 of 74
4. VentingObservations:• Efflorescence observed on vent pipe at joints,• Corrosion observed at the vent pipe, recommend further investigation
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 62 of 74
5. FiltersLocation: Filter located at bottom section of furnace • Electronic air cleaner present.Observations:• Washable aluminum mesh and flanged filters in the electronic air filter should be routinelychecked and cleaned approximately once every 2 months.
6. AC ConditionLocation: The compressor is located on the exterior east.Observations:• Could not test the air conditioning portion of unit due to outside air temperature being below 62degrees as it will damage compressor. Recommend system be serviced by licensed HVACcontractor.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 63 of 74
Plumbing/Water Heater1 1. PlumbingWater lines were copper • Drain and waste lines were plastic.
2. Water Heater ConditionHeater Type: Gas Water heater. • 50 gallonsLocation: The heater is located in the bedroom.
3. AgeApproximately 3 years of age, average life span is 10 to 12 years.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 64 of 74
4. ConditionSeismic straps are in place. • Expansion tank is in place. • Water heater has drip pan in place.Observations:• Drip pan does not have outlet drain to exterior, recommend outlet drain be installed or leak alarmsensor• Drip pan does not have outlet drain to exterior, recommend outlet drain be installed or leak alarmsensor
5. TPRV ConditionTemperature Pressure Relief Valve (TPR Valve) present.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 65 of 74
6. Venting
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 66 of 74
Electrical 1 1. LocationMaterials: Located in the Garage
2. Electrical200 AMP service, 4/0 Aluminum service entrance wires.Observations:• Generator backup system. Testing of this system is not within the scope of this inspection• Generator breaker typically would require lockout. Recommend further investigation by electricalcontractor.
Generator breaker typically would require lockout.Recommend further investigation by electrical
contractor.
3. GroundingElectrical service is bonded.
4. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 67 of 74
Foundation/Crawlspaces 1. FoundationBasement and concrete slab foundation. No visible indications of unusual settling or damage.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 68 of 74
Shutoffs 1. Shutoff Locations
||2||Air Conditioner disconnect is located adjacentto exterior portion of the air conditioner.
||2||Hot tub disconnect is located adjacent toexterior portion of the air conditioner.
||2||Water Heater gas shutoff is located to the rightof the water heater.
||2||Water heater water line shutoff is locatedabove the water heater.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 69 of 74
||2||Furnace gas shutoff is located to the left of thefurnace.
||2||Furnace disconnect is located to the left of thefurnace.
||2||Main water shutoff is located on the south wall of the garage.
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 70 of 74
Equipment 1. Appliances/Equipment
||2||AC ||2||Water Heater
||2||Furnace ||2||Refrigerator
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 71 of 74
||2||Microwave ||2||Oven
||2||Dishwasher ||2||Disposal
||2||Stove Basement family microwave
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 72 of 74
GlossaryGlossary
Term DefinitionExpansion Tank An expansion tank or expansion vessel is a small tank used to
protect closed (not open to atmospheric pressure) water heatingsystems and domestic hot water systems from excessivepressure. The tank is partially filled with air, whosecompressibility cushions shock caused by water hammer andabsorbs excess water pressure caused by thermal expansion.
GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.
TPR Valve The thermostat in a water heater shuts off the heating sourcewhen the set temperature is reached. If the thermostat fails, thewater heater could have a continuous rise in temperature andpressure (from expansion of the water). The temperature andpressure could continue to rise until the pressure exceeds thepressure capacity of the tank (300 psi). If this should happen, thesuper-heated water would boil and expand with explosive force,and the tank would burst. The super-heated water turns to steamand turns the water heater into an unguided missile. To preventthese catastrophic failures, water heaters are required to beprotected for both excess temperature and pressure. Usually, themeans of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Mostof these devices are set to operate at a water temperature above200° F and/or a pressure above 150 psi. Do not attempt to testthe TPR valve yourself! Most water heating systems should beserviced once a year as a part of an annual preventivemaintenance inspection by a professional heating and coolingcontractor. From Plumbing: Water Heater TPR Valves
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 73 of 74
Report SummaryReport Summary
The summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expense to correct or items I would like to draw extra attentionto. The summary is not a complete listing of all the findings in the report, and reflects the opinion ofthe inspector. Please review all pages of the report as the summary alone does not explain all of theissues. All repairs should be done by a licensed & bonded tradesman or qualified professional. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.Exterior AreasPage 2 Item: 1 Siding Condition • Foundation form wires protruding around foundation. These
ends can cause injury. Recommend bending over or removal,minor condition to correct.
Page 5 Item: 6 Electrical • No power to outlet, recommend further investigation andcorrection.• Outlet fixture improperly size for box, strongly recommendconditions are investigated further and corrected as requiredby licensed electrical contractor.
Deck 1Page 8 Item: 2 Deck • Ledger board secures deck to the house with nails instead of
lag bolts. Nails loosen with temperature/moisture and humiditychanges and can result in deck collapsing. Stronglyrecommend lag bolts are installed as a safety precaution.• Handrail not graspable. By today's standards, rails shouldbe configured so that a hand may grasp around a rail forsafety.
RoofPage 11 Item: 1 Roof Condition • Recommend following conditions are investigated further by
licensed roofing contractor.• Some granular surfacing deteriorated. Recommend furtherinvestigation by licensed roofing contractor
Attic 1Page 18 Item: 4 Electrical • Wire ends are outside of a Junction Box, which is a potential
shock hazard, recommend junction boxes with covers beinstalled by licensed electrical contractor
Attic 2Page 21 Item: 4 Fan/Duct • Furnace exhaust vent decayed recommend further
investigation by a licensed HVAC contractor.EntrywayPage 25 Item: 2 Electrical • Ungrounded outlets, recommend a licensed electrical
contractor investigate conditions further and correct asrequired.
Master BedroomPage 34 Item: 3 Electrical • West wall outlet has lost it’s integrity, strongly recommend
further investigation and correction by licensed electricalcontractor.
Master BathroomPage 36 Item: 3 Electrical • North wall Outlet is not GFCI protected. Strongly recommend
conditions are investigated further and corrected by licensedelectrical contractor as a safety precaution.
Bedroom 1
RW West Consultants, Inc. 4625 Highland Dr, Bellevue, WA
Page 74 of 74
Page 40 Item: 3 Electrical • Reversed polarity at west and south wall outlets,recommend a licensed electrical contractor investigateconditions further and correct as required.
Basement Family RoomPage 44 Item: 2 Electrical • Reversed polarity at south wall outlet, recommend a
licensed electrical contractor investigate conditions further andcorrect as required.
Basement BathroomPage 48 Item: 13 Windows • Tempered glass stamps not visible on the windows.
Normally windows in this location should be tempered glass incase one slips and has to brace themselves on the glass.recommend conditions are investigated further and correctedby licensed glass contractor.
Basement Laundry RoomPage 52 Item: 4 Electrical • No GFCI protection present,, strongly recommend GFCI
outlets are installed as a safety precaution.Page 53 Item: 10 Washer • Right hose bib leaks, recommend repairUtility RoomPage 55 Item: 2 Electrical • Outlet cover plates missing, recommend cover plates are
installed.GaragePage 58 Item: 3 Electrical • Improper use of extension cord observed. Extension cords
should not be permanently installed or be routed throughwalls, floors or partitions.• Outlet did not operate, recommend further investigation.
Heat/ACPage 61 Item: 4 Venting • Corrosion observed at the vent pipe, recommend further
investigationElectrical 1Page 66 Item: 2 Electrical • Generator breaker typically would require lockout.
Recommend further investigation by electrical contractor.