excite installation manual

92
Dynamic outdoor advertising solutions AlphaEclipse series Sign Installation Manual July 27, 2009 Part Number 1199613601 rev.D 16mm, 20mm, 23mm, and 35mm Pitch Signs

Upload: duane-weber

Post on 05-Apr-2015

64 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Excite Installation Manual

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 1

Dynamic outdoor advertising solutions

AlphaEclipse series

Sign Installation ManualJuly 27, 2009

Part Number 1199613601 rev. D

16mm, 20mm, 23mm, and 35mm Pitch Signs

Page 2: Excite Installation Manual

2 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

© Copyright 2009 Adaptive Micro Systems LLC. All rights reserved.Adaptive Micro Systems 7840 North 86th StreetMilwaukee, WI 53224 USA414-357-2020414-357-2029 (fax)http://www.adaptivedisplays.com

Adaptive is a registered trademark of Adaptive Micro Systems. Excite is a trademark of Adaptive Micro Systems. All other brand and product names are trademarks or registered trademarks of their respective companies.

New IP Address:

Your sign was shipped with an IP address of 10.11.11.254.

Adaptive recommends logging the new IP address below.

Page 3: Excite Installation Manual

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 1

Contents

INTRODUCTION 3

Purpose 3Revision history 3Equipment symbols 3Safety 4

High voltage 4High leakage current and earth-grounding 4Other 4

Equipment protection 5Preventing electrostatic discharge (ESD) damage 5

EQUIPMENT DESCRIPTION 9

Cases and Display Boards 9Opening case doors 12Sign exterior 13

Top and side views 13Front view 14Rear view 15

Sign interior 16Case doors 16Controller case (16mm displays) 17Controller case (20mm/20mm/35mm displays) 18

Equipment identification 19Sign label 19Case compliance label 20Shippable section identifier label 21

Temperature protection 22Sign shutdown 22Fans 22

MECHANICAL INSTALLATION 23

Overview 23Structures defined 23Super–structure design 23

Sign mounting guidelines and requirements 24Sign painting or wrapping 24Controller Requirements 25Ventilation requirements 26Wall mounting 27Monument Mounting 28Pole mounting 30

Lifting the sign 31

Page 4: Excite Installation Manual

2 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Mounting the sign to the super-structure 32Multiple shippable section sign assembly and wiring 33

About shippable sections 33Overview of power, data, and DVI cable wiring 34Wiring shippable sections together 35

ELECTRICAL INSTALLATION 41

Requirements for electrical installation 41Power requirements 42

Earth-grounding Excite signs 43Lightning strike protection 43

Installing power to the sign 44

LIGHT SENSOR ASSEMBLY 47

Guidelines for mounting the light sensor 47Installing the light sensor assembly 48

TEMPERATURE PROBE (OPTIONAL) 51

Temperature probe mounting requirements and guidelines 51

CONNECTING SIGNS 55

Connectivity options 55Ethernet option kit overview 56Fiber optic/Ethernet converter option kit overview 57WiFi option kit overview 58DSL/cable modem option overview 59

Master/slave configuration 60Setting up the sign to communicate on your network 61

APPENDIX 63

Technical specifications 63Excite 16mm pitch sign specifications 63 67Excite 20mm pitch sign specifications 67Excite 23mm pitch sign specifications 72Excite 35mm pitch sign specifications 81

Ventilation diagram for back–to–back sign configurations 89

Page 5: Excite Installation Manual

INTRODUCTION PURPOSE

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 3

Introduction

Purpose

This manual explains how to mount and electrically connect an AlphaEclipse Excite sign and is intended for sign installers.

Revision history

Equipment symbols

Revision Date Notes

rev. D June 18, 2009 Added 16mm pitch sign information throughout the manual. Updated information on automatic fan controls.

rev. C July 23, 2008 Added 20mm pitch sign information throughout the manual. Updated manual with specific ventilation and clearance requirements, including enhanced illustrations. Updated installation instructions for wiring multiple sign sections, light sensor, and temperature probes.

rev. B July 2, 2007 Corrected the Master / Slave turbo board wiring diagram. Updated information for the light sensor and the temperature probe.

rev. A November 7, 2007 Initial release.

Chassis ground

Mains power (I = On, 0 = Off)

Page 6: Excite Installation Manual

INTRODUCTION SAFETY

4 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Safety

High voltageContact with high voltage may cause death or serious injury. Always disconnect power to unit prior to servicing.

High leakage current and earth-groundingIt is essential to earth-ground the sign before connecting the power supply. Contacting signs that are not earth-grounded may cause death or serious injury.

Do not ground equipment to the sign before the sign itself is grounded. This may cause death or serious injury and damage the sign and the equipment.

OtherOther safety messages appear throughout this manual where appropriate.

Page 7: Excite Installation Manual

INTRODUCTION EQUIPMENT PROTECTION

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 5

Equipment protection

Preventing electrostatic discharge (ESD) damage

IntroductionStatic electricity is an electrical charge caused by the imbalance of electrons on the surface of an electrical component. Electrostatic Discharge (ESD) is the transfer of this charge, which can damage an electrical component. Because Adaptive signs contain EPROMs, print circuit boards (PCBs), and other static-sensitive devices, proper grounding techniques are required to remove charges before dangerous levels of static can build up.

This document shows how to prevent ESD when working with Adaptive equipment. For additional and more specific information on controlling ESD, see the Electrostatic Discharge Association Web site at http://www.esda.org/aboutesd.html.

Safety guidelinesGrounding, the act of balancing the electrical charge between yourself and a sign or electrical component by touching metal on either, must take place prior to and throughout any service procedures. To further minimize the potential for ESD damage, do the following:

• Always turn off power before removing or inserting electrical components. • Limit direct hand contact by holding electrical components at their edge and using handling tools to pry

them from their sockets. • When possible, use a static-free surface, such as an anti-static mat, to do your work.• Never slide static-sensitive devices across any type of surface—friction creates static.• Keep styrofoam, plastics, and other static-generating material away from your work area. Generally, any

non-conductive (non-metal) material can be static-generating.• If you leave your work area and then return, repeat any procedures used to ground yourself before picking

up where you left off.• Be aware that ESD increases in the winter when there is less moisture in the air.Adaptive signs are designed to be grounded whether they are on or off. However, if the wiring is disconnected, the signs are no longer grounded and you are not protected.

Page 8: Excite Installation Manual

INTRODUCTION EQUIPMENT PROTECTION

6 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Protective packagingElectrical components must always be moved or stored in an anti-static bag to provide protection against static electricity. Each bag must be marked with an ESD packaging label, indicating the component inside is static-sensitive and that appropriate caution must be taken when handling. All bags must be grounded prior to opening to remove any potential charges.

Workstation protectionIf at all possible, every service procedure performed on a sign should be carried out at an ESD-protected workstation. These workstations have a common ground point between the static-protected work surface and the personal grounding protection (such as a wrist or heel strap, or static mat) that effectively limit ESD.

Always transport or store ESD devicesin an anti-static bag.

Mark each bag with the appropriatepackaging label.

Follow protection guidelines whenever you see theESD symbol or anytime the inside of a sign isexposed. Never assume the situation is safe if the label is missing. ESD can damage circuit traces on any circuit board.

Connect all parts of the workstation directly to a common ground point.

A one-megaohm resister in the wrist band is used for wearer’s safety protection.

Connect the workstation ground to the green wire, or power supply ground, to help limit ESD. See the instructions supplied with your sign for more information.

M Ω

M Ω

Anti-static floor mat

Anti-static work mat

Anti-static wrist strap

Page 9: Excite Installation Manual

INTRODUCTION EQUIPMENT PROTECTION

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 7

To prevent ESD while working on a workstation, follow these steps when possible:

1. Remove power to the sign.2. Place the wrist strap on your wrist and wait a moment to ensure proper grounding.3. Begin working on the sign.

Note: Before removing any component stored in an anti-static bag, set the bag on the anti-static mat, then turn it over to dissipate any charge on the outside of the bag. Do the same thing to the component inside.Preventing ESD in the field

If an ESD-protected workstation is not available, do the following to effectively protect both yourself and the electrical component with which you are working:

To prevent ESD in the field:

1. Remove power to the sign.2. Put on a wrist strap. If no personal body protection is available, touch your finger to a metal surface

and skip to step 4.3. Connect the wrist strap to a piece of metal on the sign itself, then wait a moment to ensure proper

grounding.4. Before opening the sign, touch the sides of the sign’s case to discharge any remaining static electricity. 5. Using alligator clips and a jumper wire, connect the component with which you are working to the wrist

strap. If you are working without a wrist strap, connect the jumper wire to a piece of metal on the sign itself.

6. Begin working on the sign.Note: Before removing any component stored in an anti-static bag, hold the bag in one hand while

touching a metal surface with the other hand to dissipate any charge on the outside of the bag. Do the same thing to the component inside.

There may be extenuating circumstances that require additional or alternate steps, such as when you are on a ladder or truck. In these instances, grounding yourself or any tools you use is difficult. To reduce the possibility of any static discharge, handle components as little as possible and hold parts at their edges.

WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. Always disconnect power to unit prior to servicing.

WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. Always disconnect power to unit prior to servicing.

Page 10: Excite Installation Manual

INTRODUCTION EQUIPMENT PROTECTION

8 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Hot swapping componentsHot-swapping board level sign components can cause failures. These failures may occur immediately, be intermittent, or may show no symptoms until later.

Only swap board level components with the power to the sign disconnected and follow these instructions. If you need to troubleshoot components, contact Adaptive Micro Systems Technical Support at 1-800-558-7022, extension 519 during business hours.

To swap board level components:

1. Disconnect power from the sign. Disconnecting power on a row or case is insufficient, you must disconnect power from the entire sign.

2. Remove the component:• Disconnect the data connection(s) to the board first.• Disconnect the power to the board last.

3. Install the component:• Connect the power to the board first.• Connect the data connection(s) last.

WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. Always disconnect power to unit prior to servicing.

Page 11: Excite Installation Manual

EQUIPMENT DESCRIPTION CASES AND DISPLAY BOARDS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 9

Equipment description

Cases and Display Boards

AlphaEclipse Excite pitch signs are modular signs consisting of 1x2 cases (35mm only); 1x3, 1x4, 2x3, 2x4, 2x5, 2x6, 3x3, 3x4, 3x5, and 3x6 cases (16 mm only); or a combination of each size case. Each 8x16 (35mm) or 16x16 (20mm / 23mm) pixel area of a case is referred to as a display board. A 1x2 case consists of two display boards, 1x3 case consists of three display boards, and a 1x4 case consists of four display boards.

Figure 1. Display boards

16 pixels

16 pixels

16mm, 20mm and 23mm display board (16x16 pixels)

8 pixels

16 pixels

35mm display board (8x16 pixels)

Page 12: Excite Installation Manual

EQUIPMENT DESCRIPTION CASES AND DISPLAY BOARDS

10 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Figure 2. 16mm pitch sign cases

2x3 case 2x4 case

2x5 case 2x6 case

3x3 case 3x4 case

3x5 case 3x6 case

Page 13: Excite Installation Manual

1x3 case 1x4 case

EQUIPMENT DESCRIPTION CASES AND DISPLAY BOARDS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 11

Figure 3. 20mm and 23mm pitch sign cases

Figure 4. 35mm pitch sign cases

1x2 case (only used for 35mm pitch signs)

1x3 case

1x4 case

Page 14: Excite Installation Manual

EQUIPMENT DESCRIPTION OPENING CASE DOORS

12 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Opening case doors

You can access the inside of the sign by opening case doors. Each door opens from the front. The door locks are located in the top center of each cube in the case row.

All AlphaEclipse Excite sign cases open from the front.

To open a case door:

1. Disconnect all power from the sign at the power source. 2. Locate the door locks (circled below) in each door.

Two door locks (top and bottom) per driver board.

Figure 5. Door locks are in the center of each cube (20mm sign shown)

3. Use a 5/32-inch hex tool to open each door lock. Turn counter–clockwise to open the latch. Then open the door by pulling it toward you:

Open the door slowly to prevent damage to internal components.

5/32-inch hex tool(pn 6811-7076)

Figure 6. Opening the sign case door

WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. The on/off power switch on the circuit breakers DO NOT turn off power to all lines in a sign. Remove power at the source.

Sign sections must be supported (affixed to a super-structure able to withstand live loads and comply with all national and local codes) prior to opening the doors, otherwise the sign may tip causing serious injury.

Page 15: Excite Installation Manual

EQUIPMENT DESCRIPTION SIGN EXTERIOR

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 13

Sign exterior

Top and side views

A

B

B

Figure 7. Top view of a sign with multiple cases; other sizes are similar.

Figure 8. Side views of a sign with multiple cases; other sizes are similar.

Item Name Description

A SIGN MOUNTING SUB–STRUCTURE Used to mount sign.

WIRE ENTRY HOLES Used to run power and data wires between sign cases. The positions and number of holes varies based on the case size.

Left side view Right side view

B

B

Page 16: Excite Installation Manual

EQUIPMENT DESCRIPTION SIGN EXTERIOR

14 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Front viewA

B

C1

C2

B

C1

Figure 9. Front view of a sign; all sizes are similar.

Item Name Description

A LIFTING EYEBOLTS Used to lift the sign into position. Remove after the sign has been mounted.

LED DISPLAY BOARDS Used to display messages.

CONTROLLER CASE The controller case is always the bottom left-most case of the sign. In master/slave signs, only the master sign has a controller case. Depending on the sign size, it can be in a 1x3 case or a 1x4 case (a 1x2 case on 35mm signs only).

C2CONTROLLER CASE In the design of a 16mm sign, the case sizes can be 2x3, 2x4, 2x5, 2x6, 3x3, 3x4, 3x5,

and 3x6.

Page 17: Excite Installation Manual

EQUIPMENT DESCRIPTION SIGN EXTERIOR

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 15

Rear view

B

A

C

D

B

C

D

Figure 10.Rear view of a 32x64 sign, other sign sizes are similar

Item Name Description

A ELECTRICAL SERVICE ENTRY HOLE Route incoming electrical wiring conduit into this opening. The connection must be water–tight.

GROUND LUG Use to connect to an earth-ground rod. Sign must be grounded per NEC 250 and local electrical codes. See “Step 2: Ground the sign” on page 46 for details.Note: Never use the sign’s ground lug to ground welding or any other installation

equipment or the warranty will be void.

EMBEDDED PC CONTROLLER Embedded controller, only in main controller case.

CUSTOMER INTERFACE PANEL • One Ethernet port with a strain relief connector for sign connectivity.• Three connector ports for two Light sensors and one Temperature probe. See “Light

sensor assembly” on page 47 or “Temperature probe (optional)” on page 51 for details.

Page 18: Excite Installation Manual

EQUIPMENT DESCRIPTION SIGN INTERIOR

16 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Sign interior

B

C

D

The most common sign cases are shown in "Figure 11".

Figure 11.1x3 cases for a 20mm pitch sign. The 1x4 and 1x2 case sizes are similar, although 35mm sign cases are more elongated. 16mm pitch signs have 2 or 3 rows per case and one 3, 4, 5, or 6 driver boards long.

Case doors

Display boards

Figure 12. Display boards on inside case door

Display boards receive and send digital information to and from upper and lower cases. The number of display boards is based on the case size. For example, a 1x3 case would have three display boards.

Item Name Description

A MS CASE The left-most column of each sign, except for the bottom-most case, consists of the MS (Main Secondary) case.

SX CASE Most cases of a sign are SX (Secondary) cases.

MX OR CONTROLLER CASE This case is always the bottom left-most case of a sign. In master/slave configurations, there is only one controller case located in the master sign.

SD CASE The SD (Secondary Data) case contains a turbo distribution board. SD cases are odd numbered cases along the bottom row of the sign (except for the controller case).

A B

C

D

Page 19: Excite Installation Manual

EQUIPMENT DESCRIPTION SIGN INTERIOR

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 17

Controller case

G

B C E F

H I J

DA

(16mm displays)

B

C

D

E

F

G

H

I

J

Figure 13.Case component identification.

Item Name Description

A SURGE SUPPRESSOR Protects against transient surge events.

POWER DISTRIBUTION PLATE Used to route power from row to row and from power supply to power supply in each row.

CIRCUIT BREAKER Routes line voltage to the sign. The on/off switch turns power off to that entire row but AC voltage is still present at the power distribution panel.

GROUND LUG Used to ground incoming AC power. See “Installing power to the sign” on page 44 for instructions.

POWER ENTRY TERMINAL Incoming power connects to this terminal.

POWER CONDUIT HOLE Power is routed to the sign through this hole.

CONTROLLER ASSEMBLY Internal computer used to control the sign.

TURBO DISTRIBUTION BOARD Sends digital signals to the driver boards. Located in odd-numbered cases on the bottom row.

FAN Used to cool the sign components.

POWER SUPPLY Provides power to all the components in a sign case.

Page 20: Excite Installation Manual

EQUIPMENT DESCRIPTION SIGN INTERIOR

18 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Controller case (20mm/20mm/35mm displays)

A B C E F

H I J

D G

B

C

D

E

F

G

H

I

J

Figure 14.Case component identification.

Item Name Description

A CONTROLLER ASSEMBLY Internal computer used to control the sign.

POWER CONDUIT HOLE Power is routed to the sign through this hole.

POWER ENTRY TERMINAL Incoming power connects to this terminal.

GROUND LUG Used to ground incoming AC power. See “Installing power to the sign” on page 44 for instructions.

POWER DISTRIBUTION PLATE Used to route power from row to row and from power supply to power supply in each row.

SURGE SUPPRESSOR Protects against transient surge events.

CIRCUIT BREAKER Routes line voltage to the sign. The on/off switch turns power off to that entire row but AC voltage is still present at the power distribution panel.

TURBO DISTRIBUTION BOARD Sends digital signals to the driver boards. Located in odd-numbered cases on the bottom row.

POWER SUPPLY Provides power to all the components in a sign case.

FAN Used to cool the sign components.

Page 21: Excite Installation Manual

EQUIPMENT DESCRIPTION EQUIPMENT IDENTIFICATION

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 19

Equipment identification

Sign label

B

C

D

Sign labels are located on the inside and outside of each controller case.

Figure 15.Sample sign label for a 20mm 48x48 pixel sign

Item Name Description

A MODEL NUMBER

SERIAL NUMBER Consecutive, unique identification number.• The GL prefix indicates an Excite 16mm sign.• The GA prefix indicates an Excite 20mm pitch series A standard sign.• The FL prefix indicates an Excite 23mm series A sign.• The FZ or FT prefix indicates an Excite 23mm pitch series B sign.• The FN prefix indicates an Excite 35mm sign.

SERIES LETTER Revision level of sign.

ELECTRICAL INFORMATION Input voltage, frequency, and amperage.

2048RX048

GA

GA

2 0 4 8 R X 0 4 8

6A6A

A

B

C

D

EX 20 048RX048C UW 115Voltage:• 115 = 115VAC• 230 = 230VAC

Display area:Rows and columns in pixelsLED pitch (distance between any two adjacent pixels):• 16 = 16mm• 20 = 20mm• 23 = 23mm• 35 = 35mm

EX = Excite Standard

LED viewability:UW = Ultra Wide (140°/110°)

Page 22: Excite Installation Manual

EQUIPMENT DESCRIPTION EQUIPMENT IDENTIFICATION

20 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Case compliance label

B

C

ETL case compliance labels are located on the inside and outside of each case. UL case compliance labels are located on the inside and outside of each sign.

Figure 16.Sample case compliance label for a 20mm 48x48 pixel sign

Item Name Description

A CASE MODEL NUMBER Identification number for the case:

SERIES LETTER Revision level of sign.

DATE OF MANUFACTURE Month, day, and year the sign was made.

A

B

C

EX 16 RGB 048X048 MX

Case type:• MX = Main Controller Case• SX = Secondary Case• MS = Main Secondary Case• SD = Secondary Data Case

Display area:Rows and columns in pixels

LED color:RGB = Full colorLED pitch (distance between any two adjacent pixels):• 16 = 16mm• 20 = 20mm• 23 = 23mm• 35 = 35mm

EX = Excite Standard

Page 23: Excite Installation Manual

EQUIPMENT DESCRIPTION EQUIPMENT IDENTIFICATION

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 21

Shippable section identifier labelIdentifier labels are located on the back of each shippable section, near the case section compliance label.

Figure 17.Sample shippable section identifier label (20mm shown)

Item Name Description

A SERIAL NUMBER Consecutive, unique identification number. • The GL prefix indicates an Excite 16mm pitch sign.• The FS prefix indicates an Excite 20mm pitch sign.• The FL prefix indicates an Excite 23mm pitch sign.• The FN prefix indicates an Excite 35mm pitch sign.

B SERIAL NUMBER BARCODE The serial number expressed as a barcode.

C SECTION LOCATION Location of section relative to the whole sign unit.

D SIGN DESCRIPTION Indicates total rows, columns and sections for the entire sign.

A

B

C

D

Page 24: Excite Installation Manual

EQUIPMENT DESCRIPTION TEMPERATURE PROTECTION

22 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Temperature protection

Sign shutdownIf the sign reaches a thermal overload condition, one of the following failure modes will occur:

• An over-temperature fault condition at the controller will cause the sign message to blank the display and show the letters “E3” in the upper left side of the sign.

• An over-temperature fault condition at an individual power supply will cause that particular power supply to shut down. The display of the case containing this power supply will blank. The remaining displays to the left of the case with the power supply shutdown will also blank.

• An over-temperature fault condition at the controller’s power supply will result in a random or “garbled” message on the display.

Once the fault condition has cleared, the display will function normally.

FansFans are thermostatically controlled to run and cool the sign in high temperature conditions. In cooler temperatures, they do not run, which prolongs the life of the fan.

Page 25: Excite Installation Manual

MECHANICAL INSTALLATION OVERVIEW

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 23

Mechanical installation

Overview

The AlphaEclipse Excite signs uses a modular design allowing for several different sign sizes and configurations.

The sign must be installed onto a super-structure designed to withstand live loads and comply with all national and local codes. Live loads include loading from wind and seismic events. Because every sign installation is unique, there is no single procedure for mounting AlphaEclipse Excite signs.

Structures definedSub-structure: The formed steel angle on the back of each sign section (top and bottom). Supplied with the sign.

Super-structure: Customer or installer supplied structure to which the sign sections are mounted. Super–structures must be approved by a qualified structural engineer.

ID sign: Company name and/or logo sign supplied by the customer or installer. ID signs used in conjunction with Adaptive signs must not interfere with Adaptive’s ventilation, electrical, and mounting requirements.

Super–structure designThe design of a sign’s support structure depends on a number of factors: mounting methods, building codes, foundation, sign size, sign weight, sign height, wind loading, and seismic loading.

All installations, super–structure designs, and connections must be approved by a qualified structural engineer. Call Adaptive Micro Systems at 1-800-558-7022 for contact information for structural engineering consultants.

WARNING! Sign sections must be supported (affixed to a super-structure able to withstand live loads and comply with all national and local codes) prior to opening the doors, otherwise the sign may tip causing serious injury.

Notice: Sign parts could sustain damage if the doors are opened and the sign is not fully off the ground. Failure to comply voids the warranty.

Page 26: Excite Installation Manual

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

24 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Sign mounting guidelines and requirements

The method used to mount signs varies greatly from location to location. The installer must ensure the installation complies with all national and local codes.

A qualified structural engineer must review the structure and attachment points to the super-structure. The back of the sign uses a 2”x 3” x 0.14” formed steel angle. These angles assist in mounting the sign.

Sign installers must comply with the following Adaptive requirements or the sign warranty will be void:

• Any ID sign, fascia trim, or structure used above the sign must either have flashing or extend past the face of the sign.

• DO NOT allow water to pool / gather underneath or on top of the sign.• DO NOT allow water from an above ID sign, fascia trim, flashing, or any other structure to drip directly

onto the sign’s door seams.• DO NOT seal the sign in way that restricts hot air from escaping the inside of the sign.• Comply with all sign ventilation and clearance requirements. Refer to“Ventilation requirements” on

page 26 for details.

Sign painting or wrapping

Front / top view of signRear / bottom view of sign

Never paint or wrap the back or top of the sign. Painting or wrapping these areas will inhibit the sign’s ability to cool through natural convection.

The sides and bottom of the sign may be painted or vinyl wrapped without affecting the product warranty. When painting the sign, follow the paint manufacturer's instructions for surface preparation of mill finish aluminum.

Figure 18.Painting or wrapping the sign.

Notice: Do not use sign’s ground-lugs for grounding installation equipment such as welding equipment or the warranty will be void.Only the sign’s sub-structure may be welded. Welding any other part of the sign will void the warranty.

Notice: Painting or vinyl wrapping the top and/or the back of the sign will void the warranty.

Page 27: Excite Installation Manual

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 25

Controller RequirementsThe controller box is designed to be accessed from the outside of the sign. To make it easier to service the sign in this manner, make sure there is a minimum of 6 inches between the back of the sign and the adjacent surface, such as a wall.

Figure 19. Top view, showing minimum 6–inch clearance between the back of the sign and an adjacent surface

Also, when connecting the cables, leave a sufficient amount of slack to create a “Service Loop”. This will enable service personnel to remove the controller and disconnect the cables from inside the sign, if required. The loop also provides an alternate path for melting snow or rain runoff, preventing it from making contact with and damaging the connection.

Figure 20. Service loop in cables connected to the controller box.

3.0”

6.0”

Top viewSide view of an Excite sign with the Ethernet cable attached.

Adjacent surface, such as a wall Cable connection locations

Minimum cable bend radius is 5x the diameter of the cable.

Excite controller

Communication cables Cable “Service Loop”

Secure cables to the super-structure near this point ensuringNOT to kink or create additional stress / strain on the cables.

Page 28: Excite Installation Manual

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

26 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Ventilation requirements

Signs require obstruction-free space for adequate air ventilation between solid mounting surfaces and the top, bottom, and sides of the sign. This is required for all wall, monument, and pole mounted signs. Refer to “Wall mounting” on page 27, “Monument Mounting” on page 28, or “Pole mounting” on page 30 for more details.

Always take into consideration other neighboring heat sources such as backlit signs, lighting sources, etc. and add additional ventilation when needed.

Note: Shading the back of the sign will enhance thermal performance.

For every installation provide adequate ventilation or the sign warranty may be void:

• DO NOT mount air ducts (vents) directly to the sign or sign’s sub–structure.• DO NOT modify the sign or sign’s sub–structure for ventilation purposes (see Figure 26 on page 32).

The super–structure design MUST incorporate adequate ventilation.• Provide 7–square inches of ventilation for every 1–square foot of sign. For signs under 7–feet in height

use 3.5–square inches for every 1–square foot of sign. Ventilation is defined as obstruction–free space.

• Ventilation air ducts MUST be installed evenly spaced around the perimeter of the sign (top, bottom, and sides). Evenly spaced air ducts help maintain a consistent air flow around the sign.

• Air duct size MUST be a minimum of 7–square inches (equivalent to a 3–inch round air duct).• If the sides of the sign are covered (enclosed), install a minimum of two air ducts in each side covering.• Provide a minimum clearance of 1–inch above and below the sign.• Provide a minimum clearance of 6–inches behind the sign.

Notice: Inadequate ventilation will ultimately result in component failure that may not be covered under warranty.

How does the sign cool itself?Although the sign cases are completely enclosed with no forced air ventilation, the sign does rely on natural convection to cool. The top and back of the sign case use these surfaces as heat sinks to cool the inside cabinet temperatures. An internal mixing fan helps cooling by mixing the air inside bringing it all to a more uniform temperature or isothermal.

The sign is enclosed to keep out contaminants and prevent corrosion and dirt buildup, which adversely affects the sign’s performance and interferes with the sign’s ability to cool itself.

What is natural convection?Natural convection is a type of heat transportation. In natural convection, air surrounding a heat source receives heat, becomes less dense and rises. The surrounding, cooler air then moves to replace it. This cooler air is then heated and the process continues, forming a convection current.

Page 29: Excite Installation Manual

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 27

Wall mountingSigns require obstruction-free space for adequate air ventilation between solid mounting surfaces and the top, bottom, and sides of the sign.

Figure 21. Ventilation requirements around a wall mounted sign

ID SignMinimumclearance

1 inch

DO NOT allow water from the aboveID sign, fascia trim, or flashing to dripdirectly onto the sign’s door seams.

Minimumclearance

6 inches fromrearmost

projection ofdisplay

Controller

Super-structuremounting bracket

llaW

ngiSDI

ngiSDI

If sign sidesare covered,install sideair ducts.

DO NOT allow water to pool / gatherunderneath or on top of the sign. Alwayscreate a pathway for water to escape.

DO NOT modify the sign or sign’s sub-structure for ventilation purposes. Thesuper-structure design MUST incorporate adequate ventilation.

Provide 7 square inches of ventilationfor every 1 square foot of sign.

ID Sign

Minimumclearance

1 inch

Provide 7 square inches of ventilation for every 1 square foot of sign.Ventilation is defined as obstruction-free space.

Ventilation air ducts MUST be installed evenly spaced around the perimeterof the sign (top, bottom, and sides).

Evenly spaced air ducts help maintain a consistent air flow around the sign.

Use 3.5–square inches if sign height is under 7 feet.

Air duct (vent) installation for wall mounted signs

Air duct size = minimum 7–square inches (3 inch round)

Coolerair flow

Hot airflow

Coolerair flow

Hot airflow

Coolerair flow

Hot airflow

If the structure above the sign does notextend out past the sign’s door seams,install flashing to the structure.

Heat Sink(16mm only)

Page 30: Excite Installation Manual

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

28 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Monument MountingIf there is an obstruction on the outside of the sign (as in a monument-style installation), care must be taken to assure the sign is able to cool. Air ducts must be used in the monument to allow air to flow behind the sign. When monument mounting an Excite sign, use air ducts to help hot air escape. For back to back sign configurations refer to “Ventilation diagram for back–to–back sign configurations” on page 89 for details.

Note: Adaptive recommends the installation of fans to force hot air out of the air ducts.

Figure 22. Use air ducts when monument mounting.

Hotair

flow

Coolerair flow

ID Sign

Super-structuremounting bracket

Super-structuremounting bracket

Hot airflow

Hot airflow

DO NOT allow water to poolunderneath the sign.

Air duct

ID Sign

Minimumclearance6-inches

Minimumclearance

1-inch

Air duct

Monument

ID Sign

Super-structuremounting bracket

Super-structuremounting bracket

Hot airflow

Airducts

Monument

Coolerair flow

Monument MonumentDO NOT mount sign directlyon the base / floor.

Minimumclearance

1-inch

DO NOT seal off air flow.

ID Sign

Air ducts

Recommended method Alternative method

Follow these guidelines or sign warranty will be void: Clearance requirements

DO NOT allow water from theabove ID sign, fascia trim, orflashing to drip directly onto thesign’s door seams or pool ontop of the sign.

If the structure above the signdoes not extend out past thesign’s door seams, installflashing to the structure.

Page 31: Excite Installation Manual

ID Sign

Monument

Cooler air flow

Hot air flow

Hot airflow

Monument front

Super-structuremounting bracket

Coolerair flowCooler

air flow

DO NOT modify the sign orsign’s sub-structure forventilation purposes. Thesuper-structure design MUSTincorporate adequateair ventilation (super-structuremust allow hot air to escape).

Provide 7–square inches of ventilation for every 1–square footof sign. Ventilation is defined as obstruction–free space.

Ventilation air ducts MUST be installed evenly spaced around theperimeter of the sign (top, bottom, and sides).

Evenly spaced air ducts help maintain a consistent air flow aroundthe sign.

Use 3.5–square inches if sign height is under 7–feet.

Air duct size = minimum 7–square inches (3–inch round)Provide 7–square inches of ventilation

for every 1–square foot of sign.

Air duct (vent) installation for monument mounted signs

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 29

Figure 23.Monument air duct placement.

Page 32: Excite Installation Manual

MECHANICAL INSTALLATION SIGN MOUNTING GUIDELINES AND REQUIREMENTS

30 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Pole mountingSigns require obstruction-free space for adequate air ventilation between solid mounting surfaces and the top, bottom, and sides of the sign.

Figure 24. Pole mounting an Excite sign.

Coolerair flow

Coolerair flow

Coolerair flow

ID Sign

Hot airflow

Hot airflow

DO NOT wrap or paint sign top (super-structure mustallow hot air to escape).

DO NOT allow water to pool / gather underneath or on topof the sign. Always create a pathway for water to escape.

DO NOT modify the sign or sign’s sub-structure forventilation purposes.

If the structure above the sign does not extend out pastthe sign’s door seams, install flashing to the structure.

Provide a minimum clearance of 1–inch above and belowthe sign and 6–inches behind the sign.

DO NOT allow water from the above ID sign, fascia trim

,

or flashing to drip directly onto the sign’s door seams.

Hot airflow

Provide 7–square inches of ventilation for every 1–square foot of sign.Ventilation is defined as obstruction–free space.

Ventilation air ducts MUST be installed evenly spaced around the perimeterof the sign (top, bottom, and sides).

Evenly spaced air ducts help maintain a consistent air flow around the sign.

Use 3.5–square inches if sign height is under 7–feet.

Air duct (vent) installation for pole mounted signs

Air duct size = minimum 7–square inches (3–inch round)

Straps 2–inches wide and spaced nogreater than 30–inches apart. Madefrom .25–inch A–36 steel plate.

Mounting pole (super-structure)(size verified by a qualified structural engineer)

Up to48–inches

Max14–feet 8.4–inches

Saddle made from.25–inch A-36 steel plate Minimum

saddle width12– inches

4 x L3 x 3 x 0.25

Page 33: Excite Installation Manual

MECHANICAL INSTALLATION LIFTING THE SIGN

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 31

Lifting the sign

Use a lifting bar adjusted to the width of the lifting hardware on the sign to raise the shippable section. After mounting the sign sections, remove the lifting hardware or corrosion to the sign may occur. Failure to follow these instructions will void the warranty.

1. Lift the sign section up to the super-structure.2. Position the sign section on the super-structure.

PREFERRED METHOD

Lifting bar

ALTERNATE METHOD

45maximum

45maximum

Lifting bar

Lifting strap

15° Maximum lifting tilt

15° Maximum tilt

Figure 25. Sign section lifting methods

WARNING! Crush hazard. Improperly assembling or lifting a sign can create a crush hazard.

Do NOT use eyebolts to lift an assembled sign. They are designed only to lift a sign section from its shipping crate.

Lift the sign evenly and level, with no more than a 15 degree tilt.

Page 34: Excite Installation Manual

MECHANICAL INSTALLATION MOUNTING THE SIGN TO THE SUPER-STRUCTURE

32 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Mounting the sign to the super-structure

The methods used to mount a sign to a super-structure vary greatly. It is the installer’s responsibility to ensure that the installation complies with all national and local codes.

When drilling holes or welding the sign’s sub–structure, follow these guidelines or the warranty will be void:

• DO NOT drill additional conduit holes through the controller plate in the control case.• DO NOT drill additional conduit holes along the bottom of the case, because water may pool there.• DO NOT use the sign’s ground-lugs for grounding installation equipment such as welding equipment.• DO NOT weld any part of the sign except for the sign’s sub–structure.

Figure 26.Drilling guidelines

Notice: Drill holes as needed in the sign’s sub-structure for fasteners. Only drill holes into the sign when field upgrade instructions or Adaptive's Technical Service Department explicitly states to do so. Drilling holes in the sign under any other circumstance will void the sign’s warranty.

Notice: Dissimilar metals must be isolated to avoid galvanic corrosion.Any area on the sign’s frame from which paint is removed during mounting, must be recoated with paint that is UL recognized to standard UL-1332, category DTOV2. Failure to repaint the area will result in accelerated corrosion of the sign’s structure. Adaptive Micro Systems is not responsible for any failure in the sign’s structure because of accelerated corrosion. Failure to comply will void the sign’s warranty.

Drill holes nearthe sign’s sub-structure

edges.

DO NOT

Notch the sign’ssub-structure.

Drill holesgreater than 1/2”.

Drill holes1/2” or less.

Drill holes at thecenter of the sign’ssub-structure width.

Drill holes into the sides,top, bottom, or front ofthe sign cases.

Page 35: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 33

Multiple shippable section sign assembly and wiring

The instructions in this section explain how to wire power, data, and DVI between shippable sections.

• For information about wiring power to the sign, refer to “Electrical installation” on page 41. • For information about wiring data to the sign, refer to “Connecting signs” on page 55.

About shippable sectionsAlphaEclipse Excite signs are shipped in sections, referred to as “shippable sections.” Excite 20mm pitch shippable sections can be made up of 1x3 and 1x4 cases.

Signs larger than 48x128 (35mm), 96x256 (20mm / 23mm), or 144x400 (16mm) are shipped in multiple shippable sections.

Figure 27. A 128x320 pixel Excite 20mm sign would be shipped in four shippable sections

16mm pitch 20mm pitch 23mm pitch 35mm pitch

Largest Shippable Section Pixel Size: 144 x 400 96 x 256 96 x 256 48 x 128

Dimensions: 7'–7.12" x 21'–0" 6'–3.99" x 16'–9.98" 7'–3.33" x 19'–4.21" 5'–6.54" x 14'–8.78"

Example of four shippable sections for a 20mm 128x320 sign

Shippable Section A232x256

ShippableSection B1

96x64

ShippableSection B2

32x64

Shippable Section A196x256

20mm largest shippable section size is 96x256 (6’ 3.99” x 16’ 9.98”)

Page 36: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

34 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Overview of power, data, and DVI cable wiring• Power - Power is wired from the right most shippable section to the left. Each row within a shippable

section must be wired to the corresponding row in the adjacent shippable section.• Data cable - Communication cables (data) are routed from the top most shippable section down. Each

driver board column within a shippable section must be wired to the corresponding column in the shippable section below it.

• DVI cable - Digital Visual Interface (DVI) cables are routed along the bottom row between shippable sections.

Power – Route power between shippable sections through the top conduit hole of each row.

Data cable – Route data cable down from the bottom row of the upper shippable section.

DVI cable – Route DVI cable only on the bottom row of the sign between shippable sections.

This example is intended to illustrate (from the front of the sign) the approximate location of wiring (not drawn to scale).

Figure 28. Example of wiring shippable sections of a 20mm 128x320 sign

Page 37: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 35

Wiring shippable sections togetherPrior to mounting each section to a super-structure able to support the sign section weights, read the identifier label on each sign section to determine sign section location. Make sure the sign sections are mounted flush and level with one another.

Step 1: Wire power between shippable sections

PowerRoute power wiring between shippable sections through the top power conduit hole of each row.

Start here and work your way up.Figure 29.Example of wiring power between shippable sections of a 20mm 128x320 sign (not drawn to scale)

1. Open the appropriate case door(s). See “Opening case doors” on page 12 for instructions.2. Remove the stickers covering the power conduit holes. See “Sign interior” on page 16 for conduit

hole locations.3. Starting with the front-right-most shippable section, unclip the twist lock securing the wiring

harness and route the harness through the top conduit hole on the left.

Figure 30.Conduit hole in a sign case

4. Snap the wiring into the next shippable section’s power supply wiring harness power connector.5. Affix the grommet to the top conduit hole between the two sections.6. Repeat steps 1-5 for each remaining row.

Page 38: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

36 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Step 2: Wire data cable between shippable sections

Data cableRoute data cable down from the bottom cases of each column.

Start here and work your way across.

Figure 31.Example of wiring data cable between shippable sections of a 20mm 128x320 sign (not drawn to scale).

1. Start at the bottom left-most case of the top-most shippable section, unclip the twistlock securing the data cables on the left side.

• 1x2 cases have two data cables–one on each side of the case (35mm pitch sign only).

• 1x3 cases have three data cables–two on the left side of the case and one on the right side of the case.

• 1x4 cases have four data cables–two on each side of the case.

• All 16mm cases have data cables that feed vertically through the same hole in the center of the case.

Figure 32.Data cables

2. Thread the data cables down through the conduit hole and into the shippable section below it.3. Affix the grommet to the conduit holes you just ran the data cables through.

Figure 33.Vertical grommet location in sign cases. (1x4 cases shown; other case sizes are similar.)

Page 39: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 37

4. Connect the data cable(s) to the output of the corresponding driver board (refer to “Case doors” on page 16 for driver board locations).

Top of the driver board, located on the inside door section.

Tip: Connect the short cable first. It is only long enough to connect to the corresponding driver board.

Connect to the Output.

Figure 34.Input and output connections on the driver board

5. Repeat steps 1-5 for the cable(s) on the left side of the section, if applicable.6. Repeat steps 1-6 for each remaining section, if applicable.

Step 3: Wire DVI cable between shippable sections

DVI cableRoute DVI cable between shippable sections along the bottom row of the sign

Figure 35.Example of wiring DVI cable between shippable sections of a 20mm 128x320 sign (not drawn to scale).

1. Starting with the left-most case of the right-most shippable section, unclip the twistlock securing the DVI cable. Thread the DVI cable through the bottom conduit hole on the left.

Unclip the twistlock.

Route through the conduit hole.

Figure 36.DVI cable

Page 40: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

38 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

2. Plug the DVI cable into the DVI OUT connection on the turbo board. Secure the connection with the thumb screws.

Plug DVI cable in here.

Figure 37.DVI OUT on the turbo board

3. Affix the grommet to the bottom conduit hole.

Figure 38.Horizontal grommet

Page 41: Excite Installation Manual

MECHANICAL INSTALLATION MULTIPLE SHIPPABLE SECTION SIGN ASSEMBLY AND WIRING

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 39

Step 4: Attach tape between shippable sections

1. Attach tape horizontally between shippable sections.2. Attach tape vertically between shippable sections.3. After attaching tape, punch a hole through the tape at the location of each drain hole.

1

23

Back view of the sign

Figure 39. Tape locations between shippable sections

Page 42: Excite Installation Manual

THIS PAGE INTENTIONALLY BLANK

40 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

MECHANICAL INSTALLATION

Page 43: Excite Installation Manual

ELECTRICAL INSTALLATION REQUIREMENTS FOR ELECTRICAL INSTALLATION

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 41

Electrical installation

Requirements for electrical installation

The electrical installation of signs varies greatly. The following bullet points are requirements. It is the installer’s responsibility to ensure that the installation complies with all national and local codes.

• All power wiring must be from circuit breaker-protected lines.• DO NOT connect the sign to a GFI-protected circuit.• A two-pole disconnect device must be installed in the building wiring for each branch circuit supplying the

sign.• The sign must be properly grounded according to the applicable national and local electrical codes (for

example, NEC Article 250 and 600, and IEEE 1100-1999).• All electrical conduit connections must be watertight.• Use minimum 80° C copper wire only.• Torque terminals to a minimum of 7 in/lbs and a maximum of 10 in/lbs.• DO NOT drill additional conduit holes.• DO NOT route power and communication wires out of the cube door and around the side of the sign; the

wires will be damaged when the door is closed. • Separate conduits must be used for signal wires (for example, RS232, RS485) and for power wires.

However, fiber optic wire may be run in the same conduit with power wires.• Maximum circuit sizes for 16mm signs must not exceed 60 Amps.

WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. The on / off power switches on the circuit breaker DO NOT turn off power to all lines in a sign. Remove power at the source.

Notice: The following electrical installation requirements must be followed or the sign warranty will be voided.Electrical installation must only be attempted by a qualified electrician. Electrical connection must comply with all applicable national and local codes.

Page 44: Excite Installation Manual

ELECTRICAL INSTALLATION REQUIREMENTS FOR ELECTRICAL INSTALLATION

42 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Power requirementsAdequate power must be run to the sign in accordance with the “Technical specifications” on page 63.

• The sign is configured for one of two power configurations only; 115VAC single-phase or 230VAC single-phase power. The sign is NOT configured to use a 3-phase power source.

• The sign must be run on its own dedicated circuit to ensure proper operation. This is particularly important when the sign is installed in a structure containing ballasts for fluorescent lamps. They must have their own circuit. Not complying with this requirement can lead to intermittent sign operation or malfunction.• Do NOT run power to the sign and the ballasts off the same circuit.• When ballasts are used in the same vicinity of the Adaptive sign, it is recommended that they be of the

electronic low harmonic type to further reduce the risk of any interference with the sign.• Wire gauge and breakers must be sized or verified in accordance with Adaptive’s input power

specifications, the National Electric Code, and applicable local codes. Under-sizing the wire gauge or breaker size can lead to intermittent sign operation or malfunction.

• Some sign sizes require more than one circuit (power entry) according to Adaptive’s “Technical specifications” on page 63.

Is it necessary to run two conduits to a sign?It is not always necessary. Two conduits are only necessary when communication wire, like RS485 wire, is run to a sign from a computer or from another sign. In these cases, one conduit would contain the sign’s power wires and the other conduit the communication wires.

If power and communication wires are put in the same conduit, there is a chance the communication wires might pick up electrical interference from the power wires. For example, when a live power cord is placed next to a stereo speaker wire, the interference from this cord may cause the speaker to hum. In the case of a sign, this same effect could disrupt messages sent to the display.

Page 45: Excite Installation Manual

ELECTRICAL INSTALLATION EARTH-GROUNDING EXCITE SIGNS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 43

Earth-grounding Excite signs

Grounding electrode(grounding rod) Foundation

Size of ground rod must be in accordancewith national and local electrical codes.

Ground lug - locatedon the back of the sign

Earth-grounding AlphaEclipse™ Signs

Copyright 2008 Adaptive Micro Systems LLC

Equipment grounding conductor

Document No. 97197008 rev B

Signs MUST BE EARTH-GROUNDED in accordance with Article 250 of the National Electrical Code (NEC) and in

accordance with local codes or the warranty will be void.

If you have any questions, consult a certified electrician.

Connected to groundlug on back of sign

Protect the grounding electrodeagainst physical damage.

Refer to table 250.122 in theNEC for the proper size of the

equipment grounding conductor.You can get a copy of the NEC from the

National Fire Protection Assocationat www.nfpa.org.

For illustration purposes only. Not drawn to scale.

July 16, 2008

The following guidelines must be followed or the warranty will be void:• Signs must be grounded in accordance

with Article 250 of the National Electrical Code and in accordance with applicable local codes.

• Do NOT terminate the ground on metal poles or buildings. The metal will corrode resulting in deteriorated grounding properties. Additionally, metal poles or buildings are often mounted on material that does not provide an effective ground.

Adaptive also recommends the following guidelines:• Use copper-clad ground rods as the

grounding electrode. They provide effective grounding for an indefinite period of time.

• Depending on the local soil conditions and codes, more than one ground rod may need to be installed.

• Since moisture becomes more stable at greater distances below the earth's surface, when possible, install the ground rod so that eight feet extend below the frost line to lessen the deviation in the system's resistance.

• Verify the grounding electrode conductor is securely attached at both ends.

Properly grounding each sign is necessary because it is an essential means of preventing shock, shock hazards, and potential fire hazards.

Figure 40. Grounding guidelines

Lightning strike protectionA sign bonded to an earth ground has a means of dissipating the high voltage and current from a lightning strike. The resistance of the grounding electrode must be as low as possible. However, damage can still occur to a sign’s electronic equipment from lightning voltage transients.

Though some surge protection is incorporated into a sign, to protect a sign from high-voltage lightning transients, surge protectors need to be installed in accordance with NEC Articles 280 and 285 and local codes.

WARNING! Failure to properly ground the sign could result in elevated voltage from lightning entering the sign seeking a path to earth. The high voltage can result in electric shock, fires, and the destruction of the sign from lightning.

Page 46: Excite Installation Manual

ELECTRICAL INSTALLATION INSTALLING POWER TO THE SIGN

44 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Installing power to the sign

The AC power to the sign is connected to the power entry terminal in the bottom left-most case of the sign. (see “Sign interior” on page 16). To determine the circuit amperage, see “Technical specifications” on page 63.

Note: Larger Excite signs may require multiple circuit breaker protected power inputs. Power entry inputs will always be located in the left-most-bottom case of each shippable left-most section that increases the signs height.

Step 1: Wire power to the sign

1. On a two or more line sign, ensure the circuit breaker’s on / off power switch is in the off position.

The first case of each row has a circuit breaker on / off power switch.

Make sure the switches are all in the OFF position before wiring power to the sign.

X

X

X

X

X

X

X

X

Front view of sign

Figure 41. Circuit breaker on / off power switch locations.

2. Run power to the back of the sign in weather-proof conduit.

Run the power conduit into the back of the controller case here. Create a weather–tight seal between the conduit and sign connection.

Inside front view of controller

Front view of sign

Route incoming AC to the controller case (bottom left-most case).

Route incoming AC to the controller case and to the bottom left-most case of each shippable section above it. Some 35mm signs require three power inputs

Single shippable section AC wiring Multiple shippable section AC wiring

Front view of sign

Figure 42. Running power to the sign

WARNING! Hazardous voltage. Contact with high voltage may cause death or serious injury. The on / off power switches on the circuit breaker DO NOT turn off power to all lines in a sign. Remove power at the source.

Page 47: Excite Installation Manual

ELECTRICAL INSTALLATION INSTALLING POWER TO THE SIGN

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 45

3. Wire the power block.• To access the power block, pull the left side of the power block cover toward you. When you snap

off the left side, you will be able to move it to the right out of your way.• Wire the hot (black) and neutral (white) wires to the power block as shown in "Figure 43" (for

20mm/23mm/35mm models) or in “Figure 42” (for 16mm model).

Figure 43.Power block for 20mm/23mm/35mm models

Figure 44.Power block for 16mm model

Power block

Neutral(white wire)

HOT1 (black wire)

1 PHASE POWER 2 PHASE POWER

HOT1.

HOT2

Ground Ground.

HOT

HOT1

HOT2

Ground Ground

Neutral

1 PHASE POWER 2 PHASE POWER

Power block

Page 48: Excite Installation Manual

ELECTRICAL INSTALLATION INSTALLING POWER TO THE SIGN

46 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

4. Connect the ground wire to the ground lug. The ground lug is located above the power block. The internal wiring is already grounded, you will be connecting the ground for the incoming AC power.

Figure 45.Wiring incoming ground to the ground lug

Step 2: Ground the sign

1. Connect one of the grounding points to an earth-ground rod.

Connect to earth-ground rod.Tip: The ground lug is located on the back

of the controller case, directly behind the ground lug on the inside of the sign.

Figure 46.Ground lug on outside of sign

2. If applicable, repeat procedure for secondary power input.

Page 49: Excite Installation Manual

LIGHT SENSOR ASSEMBLY GUIDELINES FOR MOUNTING THE LIGHT SENSOR

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 47

Light sensor assembly

The light sensor assembly is used to control the dimming of the sign’s LEDs. It does this by monitoring the intensity of the light coming into the light sensor and adjusting the brightness of the LEDs accordingly. It’s helpful to think of this as the amount of contrast required to make the sign visible. During the night, it takes very little light to become visible, whereas during the day when things are brighter, the intensity must be raised to increase the contrast level. So at night when there is very little light, the sign automatically adjusts the LEDs to be dimmer. During the day when there is more light, the sign automatically adjusts the LEDs to be brighter.

To install the light sensor assembly, the light sensor must be mounted and connected to the controller’s customer interface panel on the back of the sign’s controller case.

A maximum of three light sensors (two if using the temperature probe) can be installed.

Guidelines for mounting the light sensor

• The light sensor must be mounted facing in the same direction the front of the sign is facing.• Make sure the light sensor is NOT in the shade because this may make it difficult to read your sign during

brighter periods of the day.• You can strap the light sensor to a pole, but make sure it is facing the same direction as the front of the

sign.• Do NOT mount light sensor directly to the sign; however it is okay to mount to the sign’s sub–structure.• The light sensor plug connection must be connected properly for a weather–tight seal.

Page 50: Excite Installation Manual

LIGHT SENSOR ASSEMBLY INSTALLING THE LIGHT SENSOR ASSEMBLY

48 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Installing the light sensor assembly

Step 1: Mount the light sensor

Use one of the following methods to mount the light sensor:

Traditional wall mount• Position the light sensor on a flat vertical surface in close proximity to the sign and make sure it is

facing the same direction as the front of the sign.• Insert six screws (not supplied) into the mounting holes (three on each side) and tighten.

Front of light sensorBack of light sensor

Facing same direction as front of sign.

Figure 47. Traditional wall mount

Perpendicular wall mount• Unscrew the two bracket screws and rotate the bracket 90 degrees.• Tighten the bracket into position with the two screws.• Position the side of the light sensor on a flat vertical surface in close proximity to the sign, making

sure it is facing the same direction as the sign.• Insert two screws (not supplied) into the mounting holes and tighten.

Bracket is turned 90 degrees

Mount side against a flat surfaceTwo bracket screws

Mounting screw holes

Figure 48. Perpendicular wall mount

Page 51: Excite Installation Manual

LIGHT SENSOR ASSEMBLY INSTALLING THE LIGHT SENSOR ASSEMBLY

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 49

Cable tie wrap installation• If applicable, unscrew the two bracket screws, rotate the bracket 90 degrees, and tighten the

bracket into position with the two screws.• In close proximity to the sign, route the cable tie wrap through the slots in the light sensor bracket

and around the pole. Make sure it is facing the same direction as the front of the sign before tightening.

Route cable tie wrap through sides

Bracket is turned 90 degrees

Two bracket screws

Figure 49. Cable tie wrap installation

Step 2: Connect the light sensor to the sign

Adaptive Micro Systems recommends that you turn off power to the sign prior to connecting the light sensor. The sign will only recognize the presence of the light sensor when it first starts. So, if you connect the light sensor while the sign is powered up, you will have to cycle power to the sign in order for it to acknowledge the presence of the light sensor.

1. Route the light sensor cable to the customer interface panel on the back of the sign’s controller case.

2. Connect the cable to the back of the controller. Leave a sufficient amount of slack to create a “Service Loop”. For more information about creating a service loop, see “Controller Requirements” on page 25.Controller on the back of the sign (bottom right-most case). Note: The light sensors can be connected

to any one of the three ports on the back of the controller. The other port is for the temperature probe.

Figure 50. Rear view of the controller from the back of the sign

Page 52: Excite Installation Manual

LIGHT SENSOR ASSEMBLY INSTALLING THE LIGHT SENSOR ASSEMBLY

50 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

• Line up the connectors and gently push the light sensor connector into one of the connectors on the back of the sign.

• Once the sealer goes in, turn the plug’s locking nut 1/2 a turn clockwise.

Figure 51. Securing the light sensor cable to the customer interface panel.

3. Repeat the process for the second light sensor.Note: The sign will not acknowledge the presence of the light sensor(s) until power is cycled.

Plug’s locking nut

Page 53: Excite Installation Manual

TEMPERATURE PROBE (OPTIONAL)

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 51

Temperature probe (optional)

When properly installed, the temperature probe (PN1288250602) will send a signal to the sign’s controller board that indicates the accurate ambient temperature near the sign. The temperature probe with the standard cable can be mounted within 25 feet of the sign. This distance can be extended by changing the length and gauge of the cable. Contact Adaptive Micro Systems Technical Support at 1-800-558-7022, extension 519 for more information.

Temperature probe mounting requirements and guidelines

Requirements for temperature probe mounting

• Vents on temperature probe must point downward.• Do NOT mount temperature probe directly to the sign; however it is okay to mount to the sign’s sub-

structure.• The temperature probe plug connection must be securely connected for a weather-tight seal.

Notice: Do NOT mount the temperature probe along the top of the sign, on the sign, near sprinklers, or water fountains.Failure to follow the temperature probe mounting requirements may cause intermittent or inaccurate operation and will not be covered by the warranty.

Page 54: Excite Installation Manual

TEMPERATURE PROBE (OPTIONAL)

52 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Guidelines for temperature probe mountingChoose a mounting location that meets the following criteria, otherwise the temperature probe will record a false temperature reading:

• Mount the temperature probe on or near the sign’s super-structure. Mount below the bottom of the sign, avoiding the intake of hot air emitting from the sign. Refer to “How does the sign cool itself?” on page 26 for details.

• Air movement is not restricted by nearby walls or other obstructions.• Mounting background is light-colored and not dark-colored.• Above vegetation and not above asphalt or blacktop.• On the north side of a building to provide protection from the sun.• Shield the probe from the effect of the direct sun, reflected heat, or any nearby sources of heat, such as

chimneys, lamps, vents, or HVAC ducts.• At least six feet off the ground, and at least one foot below the eave of a protected overhang so convection

currents (rising hot air flow) are not trapped around the temperature probe. Also, make sure convection currents are not blocked by mounting plates.

• Only one temperature probe is required in a network of signs but it must be connected to the Master sign.

Alternative mounting location within 25 feet of the master sign.

Temperature probe

Super-structure

North sideof

building

Minimum 1 foot clearance below a protected overhang

Minimum 6 foot clearance above the ground Conduit

Figure 52. Possible temperature probe mounting locations.

Page 55: Excite Installation Manual

TEMPERATURE PROBE (OPTIONAL)

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 53

Step 1: Mount the temperature probe

Mount the temperature probe so that the vents point downward.

1/2–inch and 3/4–inch trade size conduit holes

#10 screw clearance mounting holes

The temperature probe must be mounted with the vents pointing downward using the mounting holes OR the conduit holes on the bracket.

Figure 53.Temperature probe conduit and mounting holes on the bracket.

Step 2: Mount the temperature probe

Adaptive Micro Systems recommends that you turn off power to the sign prior to connecting the temperature probe. The sign will only recognize the presence of the temperature probe when it first starts. So, if you connect the temperature probe while the sign is powered up, you will have to cycle power to the sign in order for it to acknowledge the presence of the temperature probe.

1. Route the temperature probe cable to the customer interface panel on the back of the sign’s controller case.

2. Connect the cable to the back of the controller. Leave a sufficient amount of slack to create a “Service Loop”. For more information about creating a service loop, see “Controller Requirements” on page 25

Note: The temperature probe can be connected to any one of the three ports on the back of the controller. The other two ports are for the light sensor(s).

Service Loop

Figure 54.Temperature probe connection on the back of the controller case

Page 56: Excite Installation Manual

TEMPERATURE PROBE (OPTIONAL)

54 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

• Line up the connectors and gently push the temperature probe connector into one of the connectors on the back of the sign.

• Once the sealer goes in, turn the plug’s locking nut 1/2 a turn clockwise.

Figure 55. Secure the temperature probe cable to the customer interface panel.

Note: The sign will not acknowledge the presence of the temperature probe until power is cycled.

Plug’s locking nut

Page 57: Excite Installation Manual

CONNECTING SIGNS CONNECTIVITY OPTIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 55

Connecting signs

Connectivity, in the case of the AlphaEclipse Excite signs, simply means connecting your sign to your computer or network so that you can communicate and send messages to the sign. There are several options for connecting your sign to your computer or network. An overview of each type of connectivity option is provided in this section. Specific installation instructions come packaged with the option kit.

In a master / slave configuration, the master sign is connected to your computer or network and the slave sign is connected to the master sign. In this case, the master sign will receive messages from the computer running Ooh!Media over the connectivity connection. The master sign controls the display of messages on both signs. Additional slave signs are added to a sign network by adding each new sign to the last sign in the network.

The other requirement to getting your sign(s) to communicate with your network or computer is to assign it an IP address in the same range as your network or computer. Once you have the sign connected the computer or network, you can change the IP address. See “Setting up the sign to communicate on your network” on page 61 for more details.

Connectivity options

Connectivity options describe the means by which you are connecting the sign(s) to a computer or network. Each Excite sign comes with a connectivity option, sometimes referred to as a controller option.

In general, there are four options, each of which you can use to connect the sign(s) to a computer or network.

All connectivity options require the computer or network to have the TCP/IP (Transmission Control Protocol / Internet Protocol) protocol installed and configured. Today, most commercial operating systems include and install the TCP/IP protocol by default. For most people, there is no need to look for this protocol. However, if you encounter communication issues, we recommend contacting your network administrator.

Connectivity options with Ooh!Media software

Ethernet option kit page 56

Fiber optic/Ethernet converter option kit page 57

WiFi option kit page 58

DSL/cable modem option (not offered from Adaptive) page 59

Page 58: Excite Installation Manual

CONNECTING SIGNS CONNECTIVITY OPTIONS

56 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Ethernet option kit overview

* Ethernet cable must either be outdoor rated or routed through weather tight conduit.

* Ethernet CAT5 cable(300 foot maximum length)

Building wallRear view of sign

Computer running Ooh!Media software

Customer interface on back of controller

Network

Ethernet CAT5 cable(300 foot maximum length)

Using the Ethernet option, you can connect the sign to your Ethernet network or to a computer with Ethernet cabling. To use this option, your network must be using the TCP/IP protocol. For specific installation instructions, refer to the documentation in your Ethernet option kit.

This direct connection is most often used to install the sign. If you are using this type of connection permanently, make sure the Ethernet cable is outdoor rated or inside weather tight conduit.

Figure 56. Overview of connecting a sign “directly” to a computer with the Ethernet option

Figure 57. Overview of connecting a sign to an Ethernet network with the Ethernet option

Building wallRear view of sign

Computer running Ooh!Media software

Customer interface on back of controller

* Ethernet CAT5 crossover cable(300 foot maximum length)

* Ethernet crossover cable must either be outdoor rated or routed through weather tight conduit.

Page 59: Excite Installation Manual

CONNECTING SIGNS CONNECTIVITY OPTIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 57

Fiber optic/Ethernet converter option kit overviewWith this option, fiber optic/Ethernet converters are used to connect your sign to the computer or Ethernet network. The fiber optic/Ethernet converters send data between the sign and computer over a fiber optic / Ethernet connection. Using fiber optic/Ethernet converters, you can connect a sign to a computer that is up to two miles away. For specific installation instructions, refer to the documentation in your Fiber optic / Ethernet converter option kit.

Note: If applicable, plug the Ethernet cable into your network instead of directly into a computer.

Figure 58. Overview of connecting a sign with the fiber optic option

Ethernet CAT5 cable(25 feet supplied with kit)

Building wall

Rear view of sign

Computer running Ooh!Media software

Customer interface on back of controller

Ethernet CAT5 cable(300 foot maximum length)

Fiber optic enclosure with outdoor rated fiber optic/Ethernet converter

ST/ST multimode fiber optic cabling in conduit(up to 2 miles routed through weather tight conduit)

Fiber optic/Ethernet converter

Page 60: Excite Installation Manual

CONNECTING SIGNS CONNECTIVITY OPTIONS

58 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

WiFi option kit overviewTwo WiFi units are used to create a wireless bridge between your network or computer and the sign. The Access Point unit is used to transmit information to the sign. The Bridge unit is connected directly to the sign and receives information sent by the Access Point. For specific installation instructions, refer to the documentation in the WiFi option kit.

Note: If applicable, plug the Ethernet cable into your network instead of directly into a computer.

Figure 59. Overview of connecting a sign with the wireless WiFi option

Ethernet CAT5 cable

Building wall

Computer running Ooh!Media software

Customer interface on back of controller

Ethernet CAT5 cable(300 foot maximum length)

Building rooftop

Bridge

Access point

Obstruction free line of sight

Rear view of sign

Service loop

Page 61: Excite Installation Manual

CONNECTING SIGNS CONNECTIVITY OPTIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 59

DSL/cable modem option overviewUsing the Ethernet option, you can alternatively connect the sign to a DSL/cable router. If you plan to connect the sign to a DSL/cable router, you will use an Ethernet cable between the sign’s controller case and the DSL/cable router. Refer to the following illustration and consult your network administrator for additional information.

Note: Adaptive does not offer this option for purchase.

Figure 60. Overview of connecting a sign to a DSL/cable router using the Ethernet option

* Ethernet cable must either be outdoor rated or routed through weather tight conduit.

* Ethernet CAT5 cable(300 feet maximum length)

Rear view of sign

Computer running Ooh!Media software

Customer interface on back of controller

Internet Static IP address(example 207.68.172.246)

DSL/Cable router

IP address(example 192.168.1.1)Forward port #21 to the

sign’s IP address.

Firewall

Ethernet CAT5 cable

Sign IP address(example 192.168.1.100)

Page 62: Excite Installation Manual

CONNECTING SIGNS MASTER/SLAVE CONFIGURATION

60 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Master/slave configuration

When signs are connected in a master/slave configuration, they will display the same messages at the same time. Master and slave signs must be the same size. For example, if the master sign is 48x128 pixels, then the slave sign(s) must all be 48x128 pixels.

Figure 61. Turbo board connections for Master/Salve signs.

Additional slave signs are connected in the same manner, with each one added to the right of the previous sign. Refer to the documentation in the Back-to-Back Kit for specific installation instructions.

MASTER SIGN

SLAVE SIGN

LVDS (Low Voltage Differential Signal) cable

DVI (Digital Visual Interface) cable

2 4 6 8

1 3 5 7

DVI OUT

DC POWER

+ -

DVI IN 2 4 6 8

1 3 5 7

+ -

INPUT

OUTPUT

DVI OUT

DVI IN

INPUT

OUTPUT

TURBO BOARD TURBO BOARDRED

BLUE

TURBO

TURBO

fromcontroller

MASTER SIGN

SLAVE SIGN

DC POWER

Note: If the LVDS cable from the controller is in the OUTPUT port on the turbo board, switch it to the INPUT port.

Page 63: Excite Installation Manual

CONNECTING SIGNS SETTING UP THE SIGN TO COMMUNICATE ON YOUR NETWORK

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 61

Setting up the sign to communicate on your network

Regardless of how the sign will be connected to your network or computer, it must have an IP address in the same range as your computer or network. The IP address of each Excite sign is set in the factory to 10.11.11.254. This is the default IP address, the address that appears when first starting the sign.

To set the IP address on the sign, you either must install Ooh!Media on the computer or Ooh!Media must already be installed on the computer.

Setting the IP address on the sign when Ooh!Media is already installed on the computer

1. Select Start > All Programs > Ooh!Media > IP Setup Utility.

Figure 62. Ooh!Media IP setup.

2. In the Network Setup window, set the IP address information. You will need most of this from your network administrator.

See your network administrator for these settings.

Select Native.

Figure 63. Network setup.

3. If you have additional network requirements such as setting the primary DNS, click the Expert Mode box and fill in the information as instructed by your network administrator or Internet service provider.

Only use this option if instructed to do so by your network administrator, Internet service provider, or Adaptive Micro Systems.

Figure 64. Network setup expert mode

4. Click Set.

Page 64: Excite Installation Manual

CONNECTING SIGNS SETTING UP THE SIGN TO COMMUNICATE ON YOUR NETWORK

62 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

5. If the Login prompt appears, enter your password, click OK and then click Close.

By default, the password is set to ooh.

Figure 65.Login prompt

Installing Ooh!Media and setting the IP address

1. Insert the Ooh!Media CD in the CD-ROM drive on the computer.2. On the first screen, click the Install Ooh!Media button.

Click

Figure 66. Ooh!Media installation window

3. Follow the prompts until you see this one:

Figure 67. Changing IP address prompt

• If this is a new Ooh!Media installation, click Yes.• If this is an update to Ooh!Media, click No.

4. If you are changing the IP address (new installation), this prompt appears:

Figure 68. Sign connection prompt

• If the sign(s) is already connected, click OK.• If the sign(s) is not connected, connect it and then click OK.

5. Follow steps 2 through 5 of Setting the IP address on the sign when Ooh!Media is already installed on the computerBy default, the password is set to ooh.

Page 65: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 63

Appendix

Technical specifications

The most current specifications are maintained on Adaptive’s website (www.adaptivedisplays.com).

• For Excite 20mm sign specifications, go to page 67.• For Excite 23mm sign specifications, go to page 72.• For Excite 35mm sign specifications, go to page 81.

Excite 16mm pitch sign specificationsAll Excite 16mm pitch signs are 10.16 inches in depth from the front of the display to the back of the steel mounting angle.

Excite 16mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

32 64 1.00 8.16 3.00 4.32 64 1 2.9 2.9 — 1.5 1.5 —

32 96 1.00 8.16 5.00 0.48 96 1 4.1 4.1 — 2.0 2.0 —

32 112 1.00 8.16 5.00 10.56 112 1 5.2 5.2 — 2.6 2.6 —

32 128 1.00 8.16 6.00 8.63 128 1 5.7 5.7 — 2.9 2.9 —

32 144 1.00 8.16 7.00 6.71 144 1 6.4 6.4 — 3.2 3.2 —

32 160 1.00 8.16 8.00 4.79 160 1 7.0 7.0 — 3.5 3.5 —

32 176 1.00 8.16 9.00 2.87 176 1 7.6 7.6 — 3.8 3.8 —

32 192 1.00 8.16 10.00 0.95 192 1 8.2 8.2 — 4.1 4.1 —

32 208 1.00 8.16 10.00 11.03 208 1 9.2 9.2 — 4.6 4.6 —

32 224 1.00 8.16 11.00 9.11 224 1 9.8 9.8 — 4.9 4.9 —

32 240 1.00 8.16 12.00 7.19 240 1 10.4 10.4 — 5.2 5.2 —

32 256 1.00 8.16 13.00 5.26 256 1 11.0 11.0 — 5.5 5.5 —

32 272 1.00 8.16 14.00 3.34 272 1 11.7 11.7 — 5.8 5.8 —

32 288 1.00 8.16 15.00 1.42 288 1 12.3 12.3 — 6.1 6.1 —

32 304 1.00 8.16 15.00 11.50 304 1 13.3 13.3 — 6.7 6.7 —

32 320 1.00 8.16 16.00 9.58 320 1 13.9 13.9 — 7.0 7.0 —

32 336 1.00 8.16 17.00 7.66 336 1 14.5 14.5 — 7.2 7.2 —

32 352 1.00 8.16 18.00 5.74 352 1 15.1 15.1 — 7.5 7.5 —

32 368 1.00 8.16 19.00 3.82 368 1 15.7 15.7 — 7.8 7.8 —

32 384 1.00 8.16 20.00 1.89 384 1 16.2 16.2 — 8.1 8.1 —

32 400 1.00 8.16 20.00 11.97 400 1 17.4 17.4 — 8.7 8.7 —

48 64 2.00 6.24 3.00 4.32 96 1 4.3 4.3 — 2.2 2.2 —

48 96 2.00 6.24 5.00 0.48 144 1 6.1 6.1 — 3.0 3.0 —

48 112 2.00 6.24 5.00 10.56 168 1 7.7 7.7 — 3.8 3.8 —

48 128 2.00 6.24 6.00 8.63 192 1 8.5 8.5 — 4.3 4.3 —

48 144 2.00 6.24 7.00 6.71 216 1 9.5 9.5 — 4.8 4.8 —

48 160 2.00 6.24 8.00 4.79 240 1 10.4 10.4 — 5.2 5.2 —

48 176 2.00 6.24 9.00 2.87 264 1 11.3 11.3 — 5.6 5.6 —

48 192 2.00 6.24 10.00 0.95 288 1 12.2 12.2 — 6.1 6.1 —

Page 66: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

64 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

48 208 2.00 6.24 10.00 11.03 312 1 13.7 13.7 — 6.9 6.9 —

48 224 2.00 6.24 11.00 9.11 336 1 14.6 14.6 — 7.3 7.3 —

48 240 2.00 6.24 12.00 7.19 360 1 15.5 15.5 — 7.7 7.7 —

48 256 2.00 6.24 13.00 5.26 384 1 16.4 16.4 — 8.2 8.2 —

48 272 2.00 6.24 14.00 3.34 408 1 17.4 17.4 — 8.7 8.7 —

48 288 2.00 6.24 15.00 1.42 432 1 18.2 18.2 — 9.1 9.1 —

48 304 2.00 6.24 15.00 11.50 456 1 19.8 19.8 — 9.9 9.9 —

48 320 2.00 6.24 16.00 9.58 480 1 20.7 20.7 — 10.3 10.3 —

48 336 2.00 6.24 17.00 7.66 504 1 21.6 21.6 — 10.8 10.8 —

48 352 2.00 6.24 18.00 5.74 528 1 22.4 22.4 — 11.2 11.2 —

48 368 2.00 6.24 19.00 3.82 552 1 23.3 23.3 — 11.7 11.7 —

48 384 2.00 6.24 20.00 1.89 576 1 — — — 12.1 12.1 —

48 400 2.00 6.24 20.00 11.97 600 1 — — — 12.9 12.9 —

64 64 3.00 4.32 3.00 4.32 128 1 5.7 5.7 — 2.9 2.9 —

64 96 3.00 4.32 5.00 0.48 192 1 8.1 8.1 — 4.0 4.0 —

64 112 3.00 4.32 5.00 10.56 224 1 10.2 10.2 — 5.1 5.1 —

64 128 3.00 4.32 6.00 8.63 256 1 11.3 11.3 — 5.7 5.7 —

64 144 3.00 4.32 7.00 6.71 288 1 12.6 12.6 — 6.3 6.3 —

64 160 3.00 4.32 8.00 4.79 320 1 13.8 13.8 — 6.9 6.9 —

64 176 3.00 4.32 9.00 2.87 352 1 15.0 15.0 — 7.5 7.5 —

64 192 3.00 4.32 10.00 0.95 384 1 16.1 16.1 — 8.1 8.1 —

64 208 3.00 4.32 10.00 11.03 416 1 18.2 18.2 — 9.1 9.1 —

64 224 3.00 4.32 11.00 9.11 448 1 19.4 19.4 — 9.7 9.7 —

64 240 3.00 4.32 12.00 7.19 480 1 20.6 20.6 — 10.3 10.3 —

64 256 3.00 4.32 13.00 5.26 512 1 21.7 21.7 — 10.9 10.9 —

64 272 3.00 4.32 14.00 3.34 544 1 23.0 23.0 — 11.5 11.5 —

64 288 3.00 4.32 15.00 1.42 576 1 24.2 24.2 — 12.1 12.1 —

64 304 3.00 4.32 15.00 11.50 608 1 26.3 26.3 — 13.1 13.1 —

64 320 3.00 4.32 16.00 9.58 640 1 27.5 27.5 — 13.7 13.7 —

64 336 3.00 4.32 17.00 7.66 672 1 28.6 28.6 — 14.3 14.3 —

64 352 3.00 4.32 18.00 5.74 704 1 29.8 29.8 — 14.9 14.9 —

64 368 3.00 4.32 19.00 3.82 736 1 30.9 30.9 — 15.5 15.5 —

64 384 3.00 4.32 20.00 1.89 768 1 32.1 32.1 — 16.1 16.1 —

64 400 3.00 4.32 20.00 11.97 800 1 34.4 34.4 — 17.2 17.2 —

80 64 4.00 2.40 3.00 4.32 160 1 7.1 7.1 — 3.6 3.6 —

80 96 4.00 2.40 5.00 0.48 240 1 10.0 10.0 — 5.0 5.0 —

80 112 4.00 2.40 5.00 10.56 280 1 12.7 12.7 — 6.3 6.3 —

80 128 4.00 2.40 6.00 8.63 320 1 14.1 14.1 — 7.1 7.1 —

80 144 4.00 2.40 7.00 6.71 360 1 15.7 15.7 — 7.9 7.9 —

80 160 4.00 2.40 8.00 4.79 400 1 17.2 17.2 — 8.6 8.6 —

80 176 4.00 2.40 9.00 2.87 440 1 18.6 18.6 — 9.3 9.3 —

80 192 4.00 2.40 10.00 0.95 480 1 20.1 20.1 — 10.0 10.0 —

80 208 4.00 2.40 10.00 11.03 520 1 22.7 22.7 — 11.4 11.4 —

80 224 4.00 2.40 11.00 9.11 560 1 24.2 24.2 — 12.1 12.1 —

80 240 4.00 2.40 12.00 7.19 600 1 25.6 25.6 — 12.8 12.8 —

80 256 4.00 2.40 13.00 5.26 640 1 27.1 27.1 — 13.5 13.5 —

80 272 4.00 2.40 14.00 3.34 680 1 28.7 28.7 — 14.3 14.3 —

Excite 16mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 67: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 65

80 288 4.00 2.40 15.00 1.42 720 1 30.1 30.1 — 15.1 15.1 —

80 304 4.00 2.40 15.00 11.50 760 1 32.8 32.8 — 16.4 16.4 —

80 320 4.00 2.40 16.00 9.58 800 1 34.2 34.2 — 17.1 17.1 —

80 336 4.00 2.40 17.00 7.66 840 1 35.7 35.7 — 17.8 17.8 —

80 352 4.00 2.40 18.00 5.74 880 1 37.1 37.1 — 18.6 18.6 —

80 368 4.00 2.40 19.00 3.82 920 1 38.6 38.6 — 19.3 19.3 —

80 384 4.00 2.40 20.00 1.89 960 1 — — — 20.0 20.0 —

80 400 4.00 2.40 20.00 11.97 1,000 1 — — — 21.4 21.4 —

96 64 5.00 0.48 3.00 4.32 192 1 8.5 8.5 — 4.3 4.3 —

96 96 5.00 0.48 5.00 0.48 288 1 12.0 12.0 — 6.0 6.0 —

96 112 5.00 0.48 5.00 10.56 336 1 15.2 15.2 — 7.6 7.6 —

96 128 5.00 0.48 6.00 8.63 384 1 17.0 17.0 — 8.5 8.5 —

96 144 5.00 0.48 7.00 6.71 432 1 18.8 18.8 — 9.4 9.4 —

96 160 5.00 0.48 8.00 4.79 480 1 20.6 20.6 — 10.3 10.3 —

96 176 5.00 0.48 9.00 2.87 528 1 22.3 22.3 — 11.2 11.2 —

96 192 5.00 0.48 10.00 0.95 N/A 1 24.1 24.1 — 12.0 12.0 —

96 208 5.00 0.48 10.00 11.03 N/A 1 27.2 27.2 — 13.6 13.6 —

96 224 5.00 0.48 11.00 9.11 N/A 1 29.0 29.0 — 14.5 14.5 —

96 240 5.00 0.48 12.00 7.19 N/A 1 30.7 30.7 — 15.4 15.4 —

96 256 5.00 0.48 13.00 5.26 N/A 1 32.5 32.5 — 16.2 16.2 —

96 272 5.00 0.48 14.00 3.34 N/A 1 34.3 34.3 — 17.2 17.2 —

96 288 5.00 0.48 15.00 1.42 N/A 1 36.1 36.1 — 18.0 18.0 —

96 304 5.00 0.48 15.00 11.50 N/A 1 39.3 39.3 — 19.6 19.6 —

96 320 5.00 0.48 16.00 9.58 N/A 1 41.0 41.0 — 20.5 20.5 —

96 336 5.00 0.48 17.00 7.66 N/A 1 42.8 42.8 — 21.4 21.4 —

96 352 5.00 0.48 18.00 5.74 N/A 1 44.5 44.5 — 22.2 22.2 —

96 368 5.00 0.48 19.00 3.82 N/A 1 46.2 46.2 — 23.1 23.1 —

96 384 5.00 0.48 20.00 1.89 N/A 1 — — — 24.0 24.0 —

96 400 5.00 0.48 20.00 11.97 N/A 1 — — — 25.6 25.6 —

112 64 5.00 10.56 3.00 4.32 224 1 9.9 9.9 — 5.0 5.0 —

112 96 5.00 10.56 5.00 0.48 336 1 14.0 14.0 — 7.0 7.0 —

112 112 5.00 10.56 5.00 10.56 392 1 17.7 17.7 — 8.9 8.9 —

112 128 5.00 10.56 6.00 8.63 448 1 19.8 19.8 — 9.9 9.9 —

112 144 5.00 10.56 7.00 6.71 504 1 21.9 21.9 — 11.0 11.0 —

112 160 5.00 10.56 8.00 4.79 560 1 24.0 24.0 — 12.0 12.0 —

112 176 5.00 10.56 9.00 2.87 N/A 1 26.0 26.0 — 13.0 13.0 —

112 192 5.00 10.56 10.00 0.95 N/A 1 28.0 28.0 — 14.0 14.0 —

112 208 5.00 10.56 10.00 11.03 N/A 1 31.7 31.7 — 15.9 15.9 —

112 224 5.00 10.56 11.00 9.11 N/A 1 33.8 33.8 — 16.9 16.9 —

112 240 5.00 10.56 12.00 7.19 N/A 1 35.8 35.8 — 17.9 17.9 —

112 256 5.00 10.56 13.00 5.26 N/A 1 37.8 37.8 — 18.9 18.9 —

112 272 5.00 10.56 14.00 3.34 N/A 1 40.0 40.0 — 20.0 20.0 —

112 288 5.00 10.56 15.00 1.42 N/A 1 42.0 42.0 — 21.0 21.0 —

112 304 5.00 10.56 15.00 11.50 N/A 1 45.7 45.7 — 22.9 22.9 —

112 320 5.00 10.56 16.00 9.58 N/A 1 47.8 47.8 — 23.9 23.9 —

112 336 5.00 10.56 17.00 7.66 N/A 1 49.8 49.8 — 24.9 24.9 —

112 352 5.00 10.56 18.00 5.74 N/A 1 51.8 51.8 — 25.9 25.9 —

Excite 16mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 68: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

66 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

112 368 5.00 10.56 19.00 3.82 N/A 1 53.9 53.9 — 26.9 26.9 —

112 384 5.00 10.56 20.00 1.89 N/A 1 — — — 28.0 28.0 —

112 400 5.00 10.56 20.00 11.97 N/A 1 — — — 29.9 29.9 —

128 64 6.00 8.63 3.00 4.32 256 1 11.3 11.3 — 5.7 5.7 —

128 96 6.00 8.63 5.00 0.48 384 1 16.0 16.0 — 8.0 8.0 —

128 112 6.00 8.63 5.00 10.56 448 1 20.2 20.2 — 10.1 10.1 —

128 128 6.00 8.63 6.00 8.63 512 1 22.6 22.6 — 11.3 11.3 —

128 144 6.00 8.63 7.00 6.71 576 1 25.0 25.0 — 12.5 12.5 —

128 160 6.00 8.63 8.00 4.79 640 1 27.3 27.3 — 13.7 13.7 —

128 176 6.00 8.63 9.00 2.87 704 1 29.7 29.7 — 14.8 14.8 —

128 192 6.00 8.63 10.00 0.95 768 1 32.0 32.0 — 16.0 16.0 —

128 208 6.00 8.63 10.00 11.03 832 1 36.2 36.2 — 18.1 18.1 —

128 224 6.00 8.63 11.00 9.11 896 1 38.6 38.6 — 19.3 19.3 —

128 240 6.00 8.63 12.00 7.19 960 1 40.9 40.9 — 20.4 20.4 —

128 256 6.00 8.63 13.00 5.26 1,024 1 43.2 43.2 — 21.6 21.6 —

128 272 6.00 8.63 14.00 3.34 1,088 1 45.7 45.7 — 22.8 22.8 —

128 288 6.00 8.63 15.00 1.42 1,152 1 48.0 48.0 — 24.0 24.0 —

128 304 6.00 8.63 15.00 11.50 1,216 1 52.2 52.2 — 26.1 26.1 —

128 320 6.00 8.63 16.00 9.58 1,280 1 54.6 54.6 — 27.3 27.3 —

128 336 6.00 8.63 17.00 7.66 1,344 1 56.9 56.9 — 28.4 28.4 —

128 352 6.00 8.63 18.00 5.74 1,408 1 59.2 59.2 — 29.6 29.6 —

128 368 6.00 8.63 19.00 3.82 1,472 2 61.5 46.2 15.3 30.8 30.8 —

128 384 6.00 8.63 20.00 1.89 1,536 1 — — — 31.9 31.9 —

128 400 6.00 8.63 20.00 11.97 1,600 1 — — — 34.1 34.1 —

144 64 7.00 6.71 3.00 4.32 288 1 12.7 12.7 — 6.4 6.4 —

144 96 7.00 6.71 5.00 0.48 432 1 18.0 18.0 — 9.0 9.0 —

144 112 7.00 6.71 5.00 10.56 504 1 22.8 22.8 — 11.4 11.4 —

144 128 7.00 6.71 6.00 8.63 576 1 25.4 25.4 — 12.7 12.7 —

144 144 7.00 6.71 7.00 6.71 648 1 28.1 28.1 — 14.1 14.1 —

144 160 7.00 6.71 8.00 4.79 720 1 30.7 30.7 — 15.4 15.4 —

144 176 7.00 6.71 9.00 2.87 792 1 33.3 33.3 — 16.7 16.7 —

144 192 7.00 6.71 10.00 0.95 864 1 36.0 36.0 — 18.0 18.0 —

144 208 7.00 6.71 10.00 11.03 936 1 40.7 40.7 — 20.4 20.4 —

144 224 7.00 6.71 11.00 9.11 1,008 1 43.3 43.3 — 21.7 21.7 —

144 240 7.00 6.71 12.00 7.19 1,080 1 46.0 46.0 — 23.0 23.0 —

144 256 7.00 6.71 13.00 5.26 1,152 1 48.6 48.6 — 24.3 24.3 —

144 272 7.00 6.71 14.00 3.34 1,224 1 51.3 51.3 — 25.7 25.7 —

144 288 7.00 6.71 15.00 1.42 1,296 1 53.9 53.9 — 27.0 27.0 —

144 304 7.00 6.71 15.00 11.50 1,368 1 58.7 58.7 — 29.4 29.4 —

144 320 7.00 6.71 16.00 9.58 1,440 2 61.3 41.0 20.3 30.7 30.7 —

144 336 7.00 6.71 17.00 7.66 1,512 2 63.9 42.8 21.2 32.0 32.0 —

144 352 7.00 6.71 18.00 5.74 1,584 2 66.6 44.5 22.1 33.3 33.3 —

144 368 7.00 6.71 19.00 3.82 1,656 2 69.2 46.2 22.9 34.6 34.6 —

144 384 7.00 6.71 20.00 1.89 1,728 1 — — — 35.9 35.9 —

144 400 7.00 6.71 20.00 11.97 1,800 1 — — — 38.3 38.3 —

Excite 16mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 69: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 67

Excite 20mm pitch sign specificationsAll Excite 20mm pitch signs are 9.69 inches in depth from the front of the display to the back of the steel mounting angle.

Excite 20mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

16 48 1.00 1.00 3.00 2.20 39 1 1.87 1.87 — .93 .93 —

16 64 1.00 1.00 4.00 2.80 53 1 2.37 2.37 — 1.19 1.19 —

16 96 1.00 1.00 6.00 4.00 79 1 3.62 3.62 — 1.81 1.81 —

16 112 1.00 1.00 7.00 4.59 92 1 4.12 4.12 — 2.06 2.06 —

16 128 1.00 1.00 8.00 5.19 105 1 4.63 4.63 — 2.31 2.31 —

16 144 1.00 1.00 9.00 5.79 118 1 5.37 5.37 — 2.69 2.69 —

16 160 1.00 1.00 10.00 6.39 132 1 5.88 5.88 — 2.94 2.94 —

16 176 1.00 1.00 11.00 6.99 145 1 6.38 6.38 — 3.19 3.19 —

16 192 1.00 1.00 12.00 7.59 158 1 6.88 6.88 — 3.44 3.44 —

16 208 1.00 1.00 13.00 8.18 171 1 7.63 7.63 — 3.81 3.81 —

16 224 1.00 1.00 14.00 8.78 184 1 8.13 8.13 — 4.07 4.07 —

16 240 1.00 1.00 15.00 9.38 197 1 8.63 8.63 — 4.32 4.32 —

16 256 1.00 1.00 16.00 9.98 211 1 9.14 9.14 — 4.57 4.57 —

16 272 1.00 1.00 17.00 10.58 224 1 9.88 9.88 — 4.94 4.94 —

16 288 1.00 1.00 18.00 11.18 237 1 10.39 10.39 — 5.19 5.19 —

16 304 1.00 1.00 19.00 11.78 250 1 10.89 10.89 — 5.44 5.44 —

16 320 1.00 1.00 21.00 0.37 263 1 11.39 11.39 — 5.70 5.70 —

16 336 1.00 1.00 22.00 0.97 276 1 12.14 12.14 — 6.07 6.07 —

16 352 1.00 1.00 23.00 1.57 290 1 12.64 12.64 — 6.32 6.32 —

16 368 1.00 1.00 24.00 2.17 303 1 13.14 13.14 — 6.57 6.57 —

16 384 1.00 1.00 25.00 2.77 316 1 13.65 13.65 — 6.82 6.82 —

16 400 1.00 1.00 26.00 3.37 329 1 14.39 14.39 — 7.20 7.20 —

16 416 1.00 1.00 27.00 3.96 342 1 14.90 14.90 — 7.45 7.45 —

16 432 1.00 1.00 28.00 4.56 355 1 15.40 15.40 — 7.70 7.70 —

16 448 1.00 1.00 29.00 5.16 368 1 15.90 15.90 — 7.95 7.95 —

32 48 2.00 1.60 3.00 2.20 69 1 3.62 3.62 — 1.81 1.81 —

32 64 2.00 1.60 4.00 2.80 92 1 4.63 4.63 — 2.31 2.31 —

32 96 2.00 1.60 6.00 4.00 139 1 7.12 7.12 — 3.56 3.56 —

32 112 2.00 1.60 7.00 4.59 162 1 8.13 8.13 — 4.07 4.07 —

32 128 2.00 1.60 8.00 5.19 185 1 9.14 9.14 — 4.57 4.57 —

32 144 2.00 1.60 9.00 5.79 208 1 10.63 10.63 — 5.31 5.31 —

32 160 2.00 1.60 10.00 6.39 231 1 11.63 11.63 — 5.82 5.82 —

32 176 2.00 1.60 11.00 6.99 254 1 12.64 12.64 — 6.32 6.32 —

32 192 2.00 1.60 12.00 7.59 277 1 13.65 13.65 — 6.82 6.82 —

32 208 2.00 1.60 13.00 8.18 300 1 15.14 15.14 — 7.57 7.57 —

32 224 2.00 1.60 14.00 8.78 323 1 16.14 16.14 — 8.07 8.07 —

32 240 2.00 1.60 15.00 9.38 347 1 17.15 17.15 — 8.58 8.58 —

32 256 2.00 1.60 16.00 9.98 370 1 18.16 18.16 — 9.08 9.08 —

32 272 2.00 1.60 17.00 10.58 393 1 19.64 19.64 — 9.82 9.82 —

32 288 2.00 1.60 18.00 11.18 416 1 20.65 20.65 — 10.33 10.33 —

32 304 2.00 1.60 19.00 11.78 439 1 21.66 21.66 — 10.83 10.83 —

32 320 2.00 1.60 21.00 0.37 462 1 22.67 22.67 — 11.33 11.33 —

Page 70: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

68 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

32 336 2.00 1.60 22.00 0.97 485 1 24.15 24.15 — 12.08 12.08 —

32 352 2.00 1.60 23.00 1.57 508 1 25.16 25.16 — 12.58 12.58 —

32 368 2.00 1.60 24.00 2.17 531 1 26.17 26.17 — 13.08 13.08 —

32 384 2.00 1.60 25.00 2.77 554 1 27.18 27.18 — 13.59 13.59 —

32 400 2.00 1.60 26.00 3.37 578 1 28.66 28.66 — 14.33 14.33 —

32 416 2.00 1.60 27.00 3.96 601 1 29.67 29.67 — 14.84 14.84 —

32 432 2.00 1.60 28.00 4.56 624 1 30.68 30.68 — 15.34 15.34 —

32 448 2.00 1.60 29.00 5.16 647 1 31.69 31.69 — 15.84 15.84 —

48 48 3.00 2.20 3.00 2.20 95 1 5.37 5.37 — 2.69 2.69 —

48 64 3.00 2.20 4.00 2.80 126 1 6.88 6.88 — 3.44 3.44 —

48 96 3.00 2.20 6.00 4.00 189 1 10.63 10.63 — 5.31 5.31 —

48 112 3.00 2.20 7.00 4.59 221 1 12.14 12.14 — 6.07 6.07 —

48 128 3.00 2.20 8.00 5.19 252 1 13.65 13.65 — 6.82 6.82 —

48 144 3.00 2.20 9.00 5.79 284 1 15.88 15.88 — 7.94 7.94 —

48 160 3.00 2.20 10.00 6.39 315 1 17.39 17.39 — 8.70 8.70 —

48 176 3.00 2.20 11.00 6.99 347 1 18.90 18.90 — 9.45 9.45 —

48 192 3.00 2.20 12.00 7.59 378 1 20.41 20.41 — 10.21 10.21 —

48 208 3.00 2.20 13.00 8.18 410 1 22.64 22.64 — 11.32 11.32 —

48 224 3.00 2.20 14.00 8.78 441 1 24.15 24.15 — 12.08 12.08 —

48 240 3.00 2.20 15.00 9.38 473 1 25.67 25.67 — 12.83 12.83 —

48 256 3.00 2.20 16.00 9.98 504 1 27.18 27.18 — 13.59 13.59 —

48 272 3.00 2.20 17.00 10.58 536 1 29.41 29.41 — 14.70 14.70 —

48 288 3.00 2.20 18.00 11.18 567 1 30.92 30.92 — 15.46 15.46 —

48 304 3.00 2.20 19.00 11.78 599 1 32.43 32.43 — 16.22 16.22 —

48 320 3.00 2.20 21.00 0.37 630 1 33.94 33.94 — 16.97 16.97 —

48 336 3.00 2.20 22.00 0.97 662 1 36.17 36.17 — 18.09 18.09 —

48 352 3.00 2.20 23.00 1.57 693 1 37.68 37.68 — 18.84 18.84 —

48 368 3.00 2.20 24.00 2.17 725 1 39.19 39.19 — 19.60 19.60 —

48 384 3.00 2.20 25.00 2.77 756 1 40.71 40.71 — 20.35 20.35 —

48 400 3.00 2.20 26.00 3.37 788 1 42.94 42.94 — 21.47 21.47 —

48 416 3.00 2.20 27.00 3.96 819 1 44.45 44.45 — 22.22 22.22 —

48 432 3.00 2.20 28.00 4.56 851 1 45.96 45.96 — 22.98 22.98 —

48 448 3.00 2.20 29.00 5.16 882 1 47.47 47.47 — 23.74 23.74 —

64 48 4.00 2.80 3.00 2.20 126 1 7.12 7.12 — 3.56 3.56 —

64 64 4.00 2.80 4.00 2.80 168 1 9.14 9.14 — 4.57 4.57 —

64 96 4.00 2.80 6.00 4.00 252 1 14.13 14.13 — 7.06 7.06 —

64 112 4.00 2.80 7.00 4.59 294 1 16.14 16.14 — 8.07 8.07 —

64 128 4.00 2.80 8.00 5.19 336 1 18.16 18.16 — 9.08 9.08 —

64 144 4.00 2.80 9.00 5.79 378 1 21.13 21.13 — 10.57 10.57 —

64 160 4.00 2.80 10.00 6.39 420 1 23.15 23.15 — 11.57 11.57 —

64 176 4.00 2.80 11.00 6.99 462 1 25.16 25.16 — 12.58 12.58 —

64 192 4.00 2.80 12.00 7.59 504 1 27.18 27.18 — 13.59 13.59 —

64 208 4.00 2.80 13.00 8.18 546 1 30.15 30.15 — 15.08 15.08 —

64 224 4.00 2.80 14.00 8.78 588 1 32.17 32.17 — 16.08 16.08 —

64 240 4.00 2.80 15.00 9.38 630 1 34.18 34.18 — 17.09 17.09 —

64 256 4.00 2.80 16.00 9.98 672 1 36.20 36.20 — 18.10 18.10 —

64 272 4.00 2.80 17.00 10.58 714 1 39.17 39.17 — 19.59 19.59 —

64 288 4.00 2.80 18.00 11.18 756 1 41.19 41.19 — 20.59 20.59 —

Excite 20mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 71: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 69

64 304 4.00 2.80 19.00 11.78 798 1 43.20 43.20 — 21.60 21.60 —

64 320 4.00 2.80 21.00 0.37 840 1 45.22 45.22 — 22.61 22.61 —

64 336 4.00 2.80 22.00 0.97 882 1 48.19 48.19 — 24.10 24.10 —

64 352 4.00 2.80 23.00 1.57 924 1 50.21 50.21 — 25.10 25.10 —

64 368 4.00 2.80 24.00 2.17 966 1 52.22 52.22 — 26.11 26.11 —

64 384 4.00 2.80 25.00 2.77 1,008 1 54.24 54.24 — 27.12 27.12 —

64 400 4.00 2.80 26.00 3.37 1,050 1 57.21 57.21 — 28.60 28.60 —

64 416 4.00 2.80 27.00 3.96 1,092 1 59.22 59.22 — 29.61 29.61 —

64 432 4.00 2.80 28.00 4.56 1,134 1 61.24 61.24 — 30.62 30.62 —

64 448 4.00 2.80 29.00 5.16 1,176 1 63.25 63.25 — 31.63 31.63 —

80 48 5.00 3.40 3.00 2.20 158 1 8.87 8.87 — 4.44 4.44 —

80 64 5.00 3.40 4.00 2.80 210 1 11.39 11.39 — 5.70 5.70 —

80 96 5.00 3.40 6.00 4.00 315 1 17.63 17.63 — 8.82 8.82 —

80 112 5.00 3.40 7.00 4.59 368 1 20.15 20.15 — 10.07 10.07 —

80 128 5.00 3.40 8.00 5.19 420 1 22.67 22.67 — 11.33 11.33 —

80 144 5.00 3.40 9.00 5.79 473 1 26.39 26.39 — 13.19 13.19 —

80 160 5.00 3.40 10.00 6.39 525 1 28.90 28.90 — 14.45 14.45 —

80 176 5.00 3.40 11.00 6.99 578 1 31.42 31.42 — 15.71 15.71 —

80 192 5.00 3.40 12.00 7.59 630 1 33.94 33.94 — 16.97 16.97 —

80 208 5.00 3.40 13.00 8.18 683 1 37.66 37.66 — 18.83 18.83 —

80 224 5.00 3.40 14.00 8.78 735 1 40.18 40.18 — 20.09 20.09 —

80 240 5.00 3.40 15.00 9.38 788 1 42.70 42.70 — 21.35 21.35 —

80 256 5.00 3.40 16.00 9.98 840 1 45.22 45.22 — 22.61 22.61 —

80 272 5.00 3.40 17.00 10.58 893 1 48.93 48.93 — 24.47 24.47 —

80 288 5.00 3.40 18.00 11.18 945 1 51.45 51.45 — 25.73 25.73 —

80 304 5.00 3.40 19.00 11.78 998 1 53.97 53.97 — 26.99 26.99 —

80 320 5.00 3.40 21.00 0.37 1,050 1 56.49 56.49 — 28.24 28.24 —

80 336 5.00 3.40 22.00 0.97 1,103 1 60.21 60.21 — 30.10 30.10 —

80 352 5.00 3.40 23.00 1.57 1,155 1 62.73 62.73 — 31.36 31.36 —

80 368 5.00 3.40 24.00 2.17 1,208 1 65.25 65.25 — 32.62 32.62 —

80 384 5.00 3.40 25.00 2.77 1,260 1 67.76 67.76 — 33.88 33.88 —

80 400 5.00 3.40 26.00 3.37 1,313 1 71.48 71.48 — 35.74 35.74 —

80 416 5.00 3.40 27.00 3.96 1,365 1 74.00 74.00 — 37.00 37.00 —

80 432 5.00 3.40 28.00 4.56 1,418 1 76.52 76.52 — 38.26 38.26 —

80 448 5.00 3.40 29.00 5.16 1,470 1 79.04 79.04 — 39.52 39.52 —

96 48 6.00 4.00 3.00 2.20 189 1 10.63 10.63 — 5.31 5.31 —

96 64 6.00 4.00 4.00 2.80 252 1 13.65 13.65 — 6.82 6.82 —

96 96 6.00 4.00 6.00 4.00 378 1 21.13 21.13 — 10.57 10.57 —

96 112 6.00 4.00 7.00 4.59 441 1 24.15 24.15 — 12.08 12.08 —

96 128 6.00 4.00 8.00 5.19 504 1 27.18 27.18 — 13.59 13.59 —

96 144 6.00 4.00 9.00 5.79 567 1 31.64 31.64 — 15.82 15.82 —

96 160 6.00 4.00 10.00 6.39 630 1 34.66 34.66 — 17.33 17.33 —

96 176 6.00 4.00 11.00 6.99 693 1 37.68 37.68 — 18.84 18.84 —

96 192 6.00 4.00 12.00 7.59 756 1 40.71 40.71 — 20.35 20.35 —

96 208 6.00 4.00 13.00 8.18 819 1 45.17 45.17 — 22.58 22.58 —

96 224 6.00 4.00 14.00 8.78 882 1 48.19 48.19 — 24.10 24.10 —

96 240 6.00 4.00 15.00 9.38 945 1 51.21 51.21 — 25.61 25.61 —

96 256 6.00 4.00 16.00 9.98 1,008 1 54.24 54.24 — 27.12 27.12 —

Excite 20mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 72: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

70 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

96 272 6.00 4.00 17.00 10.58 1,071 1 58.70 58.70 — 29.35 29.35 —

96 288 6.00 4.00 18.00 11.18 1,134 1 61.72 61.72 — 30.86 30.86 —

96 304 6.00 4.00 19.00 11.78 1,197 1 64.74 64.74 — 32.37 32.37 —

96 320 6.00 4.00 21.00 0.37 1,260 1 67.76 67.76 — 33.88 33.88 —

96 336 6.00 4.00 22.00 0.97 1,323 1 72.23 72.23 — 36.11 36.11 —

96 352 6.00 4.00 23.00 1.57 1,386 1 75.25 75.25 — 37.62 37.62 —

96 368 6.00 4.00 24.00 2.17 1,449 1 78.27 78.27 — 39.14 39.14 —

96 384 6.00 4.00 25.00 2.77 1,512 1 81.29 81.29 — 40.65 40.65 —

96 400 6.00 4.00 26.00 3.37 1,575 1 85.76 85.76 — 42.88 42.88 —

96 416 6.00 4.00 27.00 3.96 1,638 1 88.78 88.78 — 44.39 44.39 —

96 432 6.00 4.00 28.00 4.56 1,701 1 91.80 91.80 — 45.90 45.90 —

96 448 6.00 4.00 29.00 5.16 1,764 1 94.82 94.82 — 47.41 47.41 —

112 48 7.00 4.59 3.00 2.20 221 2 12.38 10.51 1.87 6.19 5.25 0.93

112 64 7.00 4.59 4.00 2.80 294 2 15.90 13.53 2.37 7.95 6.76 1.19

112 96 7.00 4.59 6.00 4.00 441 2 24.63 21.01 3.62 12.32 10.51 1.81

112 112 7.00 4.59 7.00 4.59 515 2 28.16 24.04 4.12 14.08 12.02 2.06

112 128 7.00 4.59 8.00 5.19 588 2 31.69 27.06 4.63 15.84 13.53 2.31

112 144 7.00 4.59 9.00 5.79 662 2 36.89 31.52 5.37 18.45 15.76 2.69

112 160 7.00 4.59 10.00 6.39 735 2 40.42 34.54 5.88 20.21 17.27 2.94

112 176 7.00 4.59 11.00 6.99 809 2 43.94 37.57 6.38 21.97 18.78 3.19

112 192 7.00 4.59 12.00 7.59 882 2 47.47 40.59 6.88 23.74 20.29 3.44

112 208 7.00 4.59 13.00 8.18 956 2 52.68 45.05 7.63 26.34 22.52 3.81

112 224 7.00 4.59 14.00 8.78 1,029 2 56.20 48.07 8.13 28.10 24.04 4.07

112 240 7.00 4.59 15.00 9.38 1,103 2 59.73 51.09 8.63 29.86 25.55 4.32

112 256 7.00 4.59 16.00 9.98 1,176 2 63.25 54.12 9.14 31.63 27.06 4.57

112 272 7.00 4.59 17.00 10.58 1,250 2 68.46 58.58 9.88 34.23 29.29 4.94

112 288 7.00 4.59 18.00 11.18 1,323 2 71.99 61.60 10.39 35.99 30.80 5.19

112 304 7.00 4.59 19.00 11.78 1,397 2 75.51 64.62 10.89 37.76 32.31 5.44

112 320 7.00 4.59 21.00 0.37 1,470 2 79.04 67.65 11.39 39.52 33.82 5.70

112 336 7.00 4.59 22.00 0.97 1,544 2 84.24 72.11 12.14 42.12 36.05 6.07

112 352 7.00 4.59 23.00 1.57 1,617 2 87.77 75.13 12.64 43.89 37.57 6.32

112 368 7.00 4.59 24.00 2.17 1,691 2 91.30 78.15 13.14 45.65 39.08 6.57

112 384 7.00 4.59 25.00 2.77 1,764 2 94.82 81.17 13.65 47.41 40.59 6.82

112 400 7.00 4.59 26.00 3.37 1,838 2 100.03 85.64 14.39 50.01 42.82 7.20

112 416 7.00 4.59 27.00 3.96 1,911 2 103.55 88.66 14.90 51.78 44.33 7.45

112 432 7.00 4.59 28.00 4.56 1,985 2 107.08 91.68 15.40 53.54 45.84 7.70

112 448 7.00 4.59 29.00 5.16 2,058 2 110.61 94.70 15.90 55.30 47.35 7.95

128 48 8.00 5.19 3.00 2.20 252 2 14.13 10.51 3.62 7.06 5.25 1.81

128 64 8.00 5.19 4.00 2.80 336 2 18.16 13.53 4.63 9.08 6.76 2.31

128 96 8.00 5.19 6.00 4.00 504 2 28.14 21.01 7.12 14.07 10.51 3.56

128 112 8.00 5.19 7.00 4.59 588 2 32.17 24.04 8.13 16.08 12.02 4.07

128 128 8.00 5.19 8.00 5.19 672 2 36.20 27.06 9.14 18.10 13.53 4.57

128 144 8.00 5.19 9.00 5.79 756 2 42.15 31.52 10.63 21.07 15.76 5.31

128 160 8.00 5.19 10.00 6.39 840 2 46.18 34.54 11.63 23.09 17.27 5.82

128 176 8.00 5.19 11.00 6.99 924 2 50.21 37.57 12.64 25.10 18.78 6.32

128 192 8.00 5.19 12.00 7.59 1,008 2 54.24 40.59 13.65 27.12 20.29 6.82

128 208 8.00 5.19 13.00 8.18 1,092 2 60.18 45.05 15.14 30.09 22.52 7.57

128 224 8.00 5.19 14.00 8.78 1,176 2 64.21 48.07 16.14 32.11 24.04 8.07

Excite 20mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 73: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 71

128 240 8.00 5.19 15.00 9.38 1,260 2 68.24 51.09 17.15 34.12 25.55 8.58

128 256 8.00 5.19 16.00 9.98 1,344 2 72.27 54.12 18.16 36.14 27.06 9.08

128 272 8.00 5.19 17.00 10.58 1,428 2 78.22 58.58 19.64 39.11 29.29 9.82

128 288 8.00 5.19 18.00 11.18 1,512 2 82.25 61.60 20.65 41.13 30.80 10.33

128 304 8.00 5.19 19.00 11.78 1,596 2 86.28 64.62 21.66 43.14 32.31 10.83

128 320 8.00 5.19 21.00 0.37 1,680 2 90.31 67.65 22.67 45.16 33.82 11.33

128 336 8.00 5.19 22.00 0.97 1,764 2 96.26 72.11 24.15 48.13 36.05 12.08

128 352 8.00 5.19 23.00 1.57 1,848 2 100.29 75.13 25.16 50.15 37.57 12.58

128 368 8.00 5.19 24.00 2.17 1,932 2 104.32 78.15 26.17 52.16 39.08 13.08

128 384 8.00 5.19 25.00 2.77 2,016 2 108.35 81.17 27.18 54.18 40.59 13.59

128 400 8.00 5.19 26.00 3.37 2,100 2 114.30 85.64 28.66 57.15 42.82 14.33

128 416 8.00 5.19 27.00 3.96 2,184 2 118.33 88.66 29.67 59.17 44.33 14.84

128 432 8.00 5.19 28.00 4.56 2,268 2 122.36 91.68 30.68 61.18 45.84 15.34

128 448 8.00 5.19 29.00 5.16 2,352 2 126.39 94.70 31.69 63.20 47.35 15.84

144 48 9.00 5.79 3.00 2.20 284 2 16.00 10.63 5.37 8.00 5.31 2.69

144 64 9.00 5.79 4.00 2.80 378 2 20.53 13.65 6.88 10.27 6.82 3.44

144 96 9.00 5.79 6.00 4.00 567 2 31.76 21.13 10.63 15.88 10.57 5.31

144 112 9.00 5.79 7.00 4.59 662 2 36.29 24.15 12.14 18.15 12.08 6.07

144 128 9.00 5.79 8.00 5.19 756 2 40.82 27.18 13.65 20.41 13.59 6.82

144 144 9.00 5.79 9.00 5.79 851 2 47.52 31.64 15.88 23.76 15.82 7.94

144 160 9.00 5.79 10.00 6.39 945 2 52.05 34.66 17.39 26.03 17.33 8.70

144 176 9.00 5.79 11.00 6.99 1,040 2 56.58 37.68 18.90 28.29 18.84 9.45

144 192 9.00 5.79 12.00 7.59 1,134 2 61.12 40.71 20.41 30.56 20.35 10.21

144 208 9.00 5.79 13.00 8.18 1,229 2 67.81 45.17 22.64 33.91 22.58 11.32

144 224 9.00 5.79 14.00 8.78 1,323 2 72.35 48.19 24.15 36.17 24.10 12.08

144 240 9.00 5.79 15.00 9.38 1,418 2 76.88 51.21 25.67 38.44 25.61 12.83

144 256 9.00 5.79 16.00 9.98 1,512 2 81.41 54.24 27.18 40.71 27.12 13.59

144 272 9.00 5.79 17.00 10.58 1,607 2 88.11 58.70 29.41 44.05 29.35 14.70

144 288 9.00 5.79 18.00 11.18 1,701 2 92.64 61.72 30.92 46.32 30.86 15.46

144 304 9.00 5.79 19.00 11.78 1,796 2 97.17 64.74 32.43 48.59 32.37 16.22

144 320 9.00 5.79 21.00 0.37 1,890 2 101.71 67.76 33.94 50.85 33.88 16.97

144 336 9.00 5.79 22.00 0.97 1,985 2 108.40 72.23 36.17 54.20 36.11 18.09

144 352 9.00 5.79 23.00 1.57 2,079 2 112.93 75.25 37.68 56.47 37.62 18.84

144 368 9.00 5.79 24.00 2.17 2,174 2 117.47 78.27 39.19 58.73 39.14 19.60

144 384 9.00 5.79 25.00 2.77 2,268 2 122.00 81.29 40.71 61.00 40.65 20.35

144 400 9.00 5.79 26.00 3.37 2,363 2 128.69 85.76 42.94 64.35 42.88 21.47

144 416 9.00 5.79 27.00 3.96 2,457 2 133.23 88.78 44.45 66.61 44.39 22.22

144 432 9.00 5.79 28.00 4.56 2,552 2 137.76 91.80 45.96 68.88 45.90 22.98

144 448 9.00 5.79 29.00 5.16 2,646 2 142.29 94.82 47.47 71.15 47.41 23.74

Excite 20mm sign specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 74: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

72 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

Excite 23mm pitch sign specificationsAll Excite 23mm pitch signs are 9.69 inches in depth from the front of the display to the back of the steel mounting angle.

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

16 48 1 2.89 3 7.86 56 1 3 3 — 2 2 —16 64 1 2.89 4 10.35 75 1 4 4 — 2 2 —16 96 1 2.89 7 3.33 113 1 5 5 — 3 3 —16 112 1 2.89 8 5.82 132 1 6 6 — 3 3 —16 128 1 2.89 9 8.31 150 1 7 7 — 4 4 —16 144 1 2.89 10 10.79 169 1 8 8 — 4 4 —16 160 1 2.89 12 1.28 188 1 8 8 — 4 4 —16 176 1 2.89 13 3.77 207 1 9 9 — 5 5 —16 192 1 2.89 14 6.26 226 1 10 10 — 5 5 —16 208 1 2.89 15 8.75 244 1 11 11 — 6 6 —16 224 1 2.89 16 11.23 263 1 11 11 — 6 6 —16 240 1 2.89 18 1.72 282 1 12 12 — 6 6 —16 256 1 2.89 19 4.21 301 1 13 13 — 7 7 —16 272 1 2.89 20 6.70 320 1 14 14 — 7 7 —16 288 1 2.89 21 9.19 338 1 15 15 — 8 8 —16 304 1 2.89 22 11.68 357 1 15 15 — 8 8 —16 320 1 2.89 24 2.16 376 1 16 16 — 8 8 —16 336 1 2.89 25 4.65 395 1 17 17 — 9 9 —16 352 1 2.89 26 7.14 414 1 18 18 — 9 9 —16 368 1 2.89 27 9.63 432 1 18 18 — 9 9 —16 384 1 2.89 28 12.12 451 1 19 19 — 10 10 —16 400 1 2.89 30 2.60 470 1 20 20 — 10 10 —16 416 1 2.89 31 5.09 489 1 21 21 — 11 11 —16 432 1 2.89 32 7.58 508 1 21 21 — 11 11 —16 448 1 2.89 33 10.07 526 1 22 22 — 11 11 —16 464 1 2.89 35 0.56 545 1 — — — 12 12 —16 480 1 2.89 36 3.05 564 1 — — — 12 12 —16 496 1 2.89 37 5.53 583 1 — — — 13 13 —16 512 1 2.89 38 8.02 602 1 — — — 13 13 —16 528 1 2.89 39 10.51 620 1 — — — 13 13 —16 544 1 2.89 41 1.00 639 1 — — — 14 14 —16 560 1 2.89 42 3.49 658 1 — — — 14 14 —16 576 1 2.89 43 5.97 677 1 — — — 14 14 —16 592 1 2.89 44 8.46 696 1 — — — 15 15 —16 608 1 2.89 45 10.95 714 1 — — — 15 15 —16 624 1 2.89 47 1.44 733 1 — — — 16 16 —16 640 1 2.89 48 3.93 752 1 — — — 16 16 —32 48 2 5.38 3 7.86 99 1 5 5 — 3 3 —32 64 2 5.38 4 10.35 132 1 7 7 — 4 4 —32 96 2 5.38 7 3.33 198 1 10 10 — 5 5 —32 112 2 5.38 8 5.82 231 1 11 11 — 6 6 —32 128 2 5.38 9 8.31 264 1 13 13 — 7 7 —32 144 2 5.38 10 10.79 297 1 15 15 — 8 8 —32 160 2 5.38 12 1.28 330 1 16 16 — 8 8 —32 176 2 5.38 13 3.77 363 1 18 18 — 9 9 —32 192 2 5.38 14 6.26 396 1 19 19 — 10 10 —32 208 2 5.38 15 8.75 429 1 21 21 — 11 11 —32 224 2 5.38 16 11.23 462 1 22 22 — 11 11 —32 240 2 5.38 18 1.72 495 1 24 24 — 12 12 —

Page 75: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 73

32 256 2 5.38 19 4.21 528 1 25 25 — 13 13 —32 272 2 5.38 20 6.70 561 1 27 27 — 14 14 —32 288 2 5.38 21 9.19 594 1 29 29 — 15 15 —32 304 2 5.38 22 11.68 627 1 30 30 — 15 15 —32 320 2 5.38 24 2.16 660 1 31 31 — 16 16 —32 336 2 5.38 25 4.65 693 1 33 33 — 17 17 —32 352 2 5.38 26 7.14 726 1 35 35 — 18 18 —32 368 2 5.38 27 9.63 759 1 36 36 — 18 18 —32 384 2 5.38 28 12.12 792 1 38 38 — 19 19 —32 400 2 5.38 30 2.60 825 1 40 40 — 20 20 —32 416 2 5.38 31 5.09 858 1 41 41 — 21 21 —32 432 2 5.38 32 7.58 891 1 42 42 — 21 21 —32 448 2 5.38 33 10.07 924 1 44 44 — 22 22 —32 464 2 5.38 35 0.56 957 1 — — — 23 23 —32 480 2 5.38 36 3.05 990 1 — — — 24 24 —32 496 2 5.38 37 5.53 1,023 1 — — — 25 25 —32 512 2 5.38 38 8.02 1,056 1 — — — 25 25 —32 528 2 5.38 39 10.51 1,089 1 — — — 26 26 —32 544 2 5.38 41 1.00 1,122 1 — — — 27 27 —32 560 2 5.38 42 3.49 1,155 1 — — — 28 28 —32 576 2 5.38 43 5.97 1,188 1 — — — 28 28 —32 592 2 5.38 44 8.46 1,221 1 — — — 29 29 —32 608 2 5.38 45 10.95 1,254 1 — — — 30 30 —32 624 2 5.38 47 1.44 1,287 1 — — — 31 31 —32 640 2 5.38 48 3.93 1,320 1 — — — 31 31 —48 48 3 7.86 3 7.86 135 1 8 8 — 4 4 —48 64 3 7.86 4 10.35 180 1 10 10 — 5 5 —48 96 3 7.86 7 3.33 270 1 15 15 — 8 8 —48 112 3 7.86 8 5.82 315 1 17 17 — 9 9 —48 128 3 7.86 9 8.31 360 1 19 19 — 10 10 —48 144 3 7.86 10 10.79 405 1 22 22 — 11 11 —48 160 3 7.86 12 1.28 450 1 24 24 — 12 12 —48 176 3 7.86 13 3.77 495 1 26 26 — 13 13 —48 192 3 7.86 14 6.26 540 1 28 28 — 14 14 —48 208 3 7.86 15 8.75 585 1 31 31 — 16 16 —48 224 3 7.86 16 11.23 630 1 33 33 — 17 17 —48 240 3 7.86 18 1.72 675 1 36 36 — 18 18 —48 256 3 7.86 19 4.21 720 1 38 38 — 19 19 —48 272 3 7.86 20 6.70 765 1 41 41 — 21 21 —48 288 3 7.86 21 9.19 810 1 43 43 — 22 22 —48 304 3 7.86 22 11.68 855 1 45 45 — 23 23 —48 320 3 7.86 24 2.16 900 1 47 47 — 24 24 —48 336 3 7.86 25 4.65 945 1 50 50 — 25 25 —48 352 3 7.86 26 7.14 990 1 52 52 — 26 26 —48 368 3 7.86 27 9.63 1,035 1 54 54 — 27 27 —48 384 3 7.86 28 12.12 1,080 1 56 56 — 28 28 —48 400 3 7.86 30 2.60 1,125 1 59 59 — 30 30 —48 416 3 7.86 31 5.09 1,170 1 61 61 — 31 31 —48 432 3 7.86 32 7.58 1,215 1 63 63 — 32 32 —48 448 3 7.86 33 10.07 1,260 1 66 66 — 33 33 —48 464 3 7.86 35 0.56 1,305 1 — — — 34 34 —48 480 3 7.86 36 3.05 1,350 1 — — — 36 36 —48 496 3 7.86 37 5.53 1,395 1 — — — 37 37 —48 512 3 7.86 38 8.02 1,440 1 — — — 38 38 —

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 76: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

74 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

48 528 3 7.86 39 10.51 1,485 1 — — — 39 39 —48 544 3 7.86 41 1.00 1,530 1 — — — 40 40 —48 560 3 7.86 42 3.49 1,575 1 — — — 41 41 —48 576 3 7.86 43 5.97 1,620 1 — — — 42 42 —48 592 3 7.86 44 8.46 1,665 1 — — — 44 44 —48 608 3 7.86 45 10.95 1,710 1 — — — 45 45 —48 624 3 7.86 47 1.44 1,755 1 — — — 46 46 —48 640 3 7.86 48 3.93 1,800 1 — — — 47 47 —64 48 4 10.35 3 7.86 180 1 10 10 — 5 5 —64 64 4 10.35 4 10.35 240 1 13 13 — 7 7 —64 96 4 10.35 7 3.33 360 1 20 20 — 10 10 —64 112 4 10.35 8 5.82 420 1 22 22 — 11 11 —64 128 4 10.35 9 8.31 480 1 25 25 — 13 13 —64 144 4 10.35 10 10.79 540 1 29 29 — 15 15 —64 160 4 10.35 12 1.28 600 1 32 32 — 16 16 —64 176 4 10.35 13 3.77 660 1 35 35 — 18 18 —64 192 4 10.35 14 6.26 720 1 38 38 — 19 19 —64 208 4 10.35 15 8.75 780 1 41 41 — 21 21 —64 224 4 10.35 16 11.23 840 1 44 44 — 22 22 —64 240 4 10.35 18 1.72 900 1 47 47 — 24 24 —64 256 4 10.35 19 4.21 960 1 50 50 — 25 25 —64 272 4 10.35 20 6.70 1,020 1 54 54 — 27 27 —64 288 4 10.35 21 9.19 1,080 1 57 57 — 29 29 —64 304 4 10.35 22 11.68 1,140 1 60 60 — 30 30 —64 320 4 10.35 24 2.16 1,200 1 62 62 — 31 31 —64 336 4 10.35 25 4.65 1,260 1 66 66 — 33 33 —64 352 4 10.35 26 7.14 1,320 1 69 69 — 35 35 —64 368 4 10.35 27 9.63 1,380 1 72 72 — 36 36 —64 384 4 10.35 28 12.12 1,440 1 75 75 — 38 38 —64 400 4 10.35 30 2.60 1,500 1 79 79 — 40 40 —64 416 4 10.35 31 5.09 1,560 1 81 81 — 41 41 —64 432 4 10.35 32 7.58 1,620 1 84 84 — 42 42 —64 448 4 10.35 33 10.07 1,680 1 87 87 — 44 44 —64 464 4 10.35 35 0.56 1,740 1 — — — 46 46 —64 480 4 10.35 36 3.05 1,800 1 — — — 47 47 —64 496 4 10.35 37 5.53 1,860 1 — — — 49 49 —64 512 4 10.35 38 8.02 1,920 1 — — — 50 50 —64 528 4 10.35 39 10.51 1,980 1 — — — 52 52 —64 544 4 10.35 41 1.00 2,040 1 — — — 53 53 —64 560 4 10.35 42 3.49 2,100 1 — — — 55 55 —64 576 4 10.35 43 5.97 2,160 1 — — — 56 56 —64 592 4 10.35 44 8.46 2,220 1 — — — 58 58 —64 608 4 10.35 45 10.95 2,280 1 — — — 60 60 —64 624 4 10.35 47 1.44 2,340 1 — — — 61 61 —64 640 4 10.35 48 3.93 2,400 1 — — — 62 62 —80 48 6 0.84 3 7.86 225 1 12 12 — 6 6 —80 64 6 0.84 4 10.35 300 1 16 16 — 8 8 —80 96 6 0.84 7 3.33 450 1 24 24 N/A 12 12 —80 112 6 0.84 8 5.82 525 1 28 28 N/A 14 14 —80 128 6 0.84 9 8.31 600 1 31 31 N/A 16 16 —80 144 6 0.84 10 10.79 675 1 36 36 N/A 18 18 —80 160 6 0.84 12 1.28 750 1 40 40 N/A 20 20 —80 176 6 0.84 13 3.77 825 1 43 43 N/A 22 22 —80 192 6 0.84 14 6.26 900 1 47 47 N/A 24 24 —

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 77: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 75

80 208 6 0.84 15 8.75 975 1 52 52 N/A 26 26 —80 224 6 0.84 16 11.23 1,050 1 55 55 N/A 28 28 —80 240 6 0.84 18 1.72 1,125 1 59 59 N/A 30 30 —80 256 6 0.84 19 4.21 1,200 1 62 62 N/A 31 31 —80 272 6 0.84 20 6.70 1,275 1 67 67 N/A 34 34 —80 288 6 0.84 21 9.19 1,350 1 71 71 N/A 36 36 —80 304 6 0.84 22 11.68 1,425 1 74 74 N/A 37 37 —80 320 6 0.84 24 2.16 1,500 1 78 78 N/A 39 39 —80 336 6 0.84 25 4.65 1,575 1 83 83 N/A 42 42 —80 352 6 0.84 26 7.14 1,650 1 86 86 N/A 43 43 —80 368 6 0.84 27 9.63 1,725 1 90 90 N/A 45 45 —80 384 6 0.84 28 12.12 1,800 1 93 93 N/A 47 47 —80 400 6 0.84 30 2.60 1,875 1 98 98 N/A 49 49 —80 416 6 0.84 31 5.09 1,950 1 102 102 N/A 51 51 —80 432 6 0.84 32 7.58 2,025 1 105 105 N/A 53 53 —80 448 6 0.84 33 10.07 2,100 1 109 109 N/A 55 55 —80 464 6 0.84 35 0.56 2,175 1 — — — 57 57 —80 480 6 0.84 36 3.05 2,250 1 — — — 59 59 —80 496 6 0.84 37 5.53 2,325 1 — — — 61 61 —80 512 6 0.84 38 8.02 2,400 1 — — — 62 62 —80 528 6 0.84 39 10.51 2,475 1 — — — 65 65 —80 544 6 0.84 41 1.00 2,550 1 — — — 67 67 —80 560 6 0.84 42 3.49 2,625 1 — — — 68 68 —80 576 6 0.84 43 5.97 2,700 1 — — — 70 70 —80 592 6 0.84 44 8.46 2,775 1 — — — 73 73 —80 608 6 0.84 45 10.95 2,850 1 — — — 74 74 —80 624 6 0.84 47 1.44 2,925 1 — — — 76 76 —80 640 6 0.84 48 3.93 3,000 1 — — — 78 78 —96 48 7 3.33 3 7.86 270 1 15 15 — 8 8 —96 64 7 3.33 4 10.35 360 1 19 19 — 10 10 —96 96 7 3.33 7 3.33 540 1 29 29 — 15 15 —96 112 7 3.33 8 5.82 630 1 33 33 — 17 17 —96 128 7 3.33 9 8.31 720 1 38 38 — 19 19 —96 144 7 3.33 10 10.79 810 1 43 43 — 22 22 —96 160 7 3.33 12 1.28 900 1 48 48 — 24 24 —96 176 7 3.33 13 3.77 990 1 52 52 — 26 26 —96 192 7 3.33 14 6.26 1,080 1 56 56 — 28 28 —96 208 7 3.33 15 8.75 1,170 1 62 62 — 31 31 —96 224 7 3.33 16 11.23 1,260 1 66 66 — 33 33 —96 240 7 3.33 18 1.72 1,350 1 71 71 — 36 36 —96 256 7 3.33 19 4.21 1,440 1 75 75 — 38 38 —96 272 7 3.33 20 6.70 1,530 1 81 81 — 41 41 —96 288 7 3.33 21 9.19 1,620 1 85 85 — 43 43 —96 304 7 3.33 22 11.68 1,710 1 89 89 — 45 45 —96 320 7 3.33 24 2.16 1,800 1 93 93 — 47 47 —96 336 7 3.33 25 4.65 1,890 1 99 99 — 50 50 —96 352 7 3.33 26 7.14 1,980 1 103 103 — 52 52 —96 368 7 3.33 27 9.63 2,070 1 108 108 — 54 54 —96 384 7 3.33 28 12.12 2,160 1 112 112 — 56 56 —96 400 7 3.33 30 2.60 2,250 1 118 118 — 59 59 —96 416 7 3.33 31 5.09 2,340 1 122 122 — 61 61 —96 432 7 3.33 32 7.58 2,430 1 126 126 — 63 63 —96 448 7 3.33 33 10.07 2,520 1 131 131 — 66 66 —96 464 7 3.33 35 0.56 2,610 1 — — — 68 68 —

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 78: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

76 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

96 480 7 3.33 36 3.05 2,700 1 — — — 71 71 —96 496 7 3.33 37 5.53 2,790 1 — — — 73 73 —96 512 7 3.33 38 8.02 2,880 1 — — — 75 75 —96 528 7 3.33 39 10.51 2,970 1 — — — 78 78 —96 544 7 3.33 41 1.00 3,060 1 — — — 80 80 —96 560 7 3.33 42 3.49 3,150 1 — — — 82 82 —96 576 7 3.33 43 5.97 3,240 1 — — — 84 84 —96 592 7 3.33 44 8.46 3,330 1 — — — 87 87 —96 608 7 3.33 45 10.95 3,420 1 — — — 89 89 —96 624 7 3.33 47 1.44 3,510 1 — — — 91 91 —96 640 7 3.33 48 3.93 3,600 1 — — — 93 93 —112 48 8 5.82 3 7.86 315 2 17 9.71 7.29 9 5.14 3.86112 64 8 5.82 4 10.35 420 2 22 12.57 9.43 11 6.29 4.71112 96 8 5.82 7 3.33 630 2 34 19.43 14.57 17 9.71 7.29112 112 8 5.82 8 5.82 735 2 39 22.29 16.71 20 11.43 8.57112 128 8 5.82 9 8.31 840 2 44 25.14 18.86 22 12.57 9.43112 144 8 5.82 10 10.79 945 2 51 29.14 21.86 26 14.86 11.14112 160 8 5.82 12 1.28 1,050 2 56 32.00 24.00 28 16.00 12.00112 176 8 5.82 13 3.77 1,155 2 61 34.86 26.14 31 17.71 13.29112 192 8 5.82 14 6.26 1,260 2 66 37.71 28.29 33 18.86 14.14112 208 8 5.82 15 8.75 1,365 2 72 41.14 30.86 36 20.57 15.43112 224 8 5.82 16 11.23 1,470 2 77 44.00 33.00 39 22.29 16.71112 240 8 5.82 18 1.72 1,575 2 82 46.86 35.14 41 23.43 17.57112 256 8 5.82 19 4.21 1,680 2 87 49.71 37.29 44 25.14 18.86112 272 8 5.82 20 6.70 1,785 2 94 53.71 40.29 47 26.86 20.14112 288 8 5.82 21 9.19 1,890 2 99 56.57 42.43 50 28.57 21.43112 304 8 5.82 22 11.68 1,995 2 104 59.43 44.57 52 29.71 22.29112 320 8 5.82 24 2.16 2,100 2 109 62.29 46.71 55 31.43 23.57112 336 8 5.82 25 4.65 2,205 2 116 66.29 49.71 58 33.14 24.86112 352 8 5.82 26 7.14 2,310 2 121 69.14 51.86 61 34.86 26.14112 368 8 5.82 27 9.63 2,415 2 126 72.00 54.00 63 36.00 27.00112 384 8 5.82 28 12.12 2,520 2 131 74.86 56.14 66 37.71 28.29112 400 8 5.82 30 2.60 2,625 2 137 78.29 58.71 69 39.43 29.57112 416 8 5.82 31 5.09 2,730 2 142 81.14 60.86 71 40.57 30.43112 432 8 5.82 32 7.58 2,835 2 147 84.00 63.00 74 42.29 31.71112 448 8 5.82 33 10.07 2,940 2 152 86.86 65.14 76 43.43 32.57112 464 8 5.82 35 0.56 3,045 2 — — — 80 45.71 34.29112 480 8 5.82 36 3.05 3,150 2 — — — 82 46.86 35.14112 496 8 5.82 37 5.53 3,255 2 — — — 85 48.57 36.43112 512 8 5.82 38 8.02 3,360 2 — — — 87 49.71 37.29112 528 8 5.82 39 10.51 3,465 2 — — — 91 52.00 39.00112 544 8 5.82 41 1.00 3,570 2 — — — 93 53.14 39.86112 560 8 5.82 42 3.49 3,675 2 — — — 96 54.86 41.14112 576 8 5.82 43 5.97 3,780 2 — — — 98 56.00 42.00112 592 8 5.82 44 8.46 3,885 2 — — — 101 57.71 43.29112 608 8 5.82 45 10.95 3,990 2 — — — 104 59.43 44.57112 624 8 5.82 47 1.44 4,095 2 — — — 106 60.57 45.43112 640 8 5.82 48 3.93 4,200 2 — — — 109 62.29 46.71128 48 9 8.31 3 7.86 360 2 20 10 10 10 5 5128 64 9 8.31 4 10.35 480 2 25 12.5 12.5 13 6.5 6.5128 96 9 8.31 7 3.33 720 2 39 19.5 19.5 20 10 10128 112 9 8.31 8 5.82 840 2 44 22 22 22 11 11128 128 9 8.31 9 8.31 960 2 50 25 25 25 12.5 12.5128 144 9 8.31 10 10.79 1,080 2 58 29 29 29 14.5 14.5

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 79: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 77

128 160 9 8.31 12 1.28 1,200 2 63 31.5 31.5 32 16 16128 176 9 8.31 13 3.77 1,320 2 69 34.5 34.5 35 17.5 17.5128 192 9 8.31 14 6.26 1,440 2 75 37.5 37.5 38 19 19128 208 9 8.31 15 8.75 1,560 2 82 41 41 41 20.5 20.5128 224 9 8.31 16 11.23 1,680 2 88 44 44 44 22 22128 240 9 8.31 18 1.72 1,800 2 94 47 47 47 23.5 23.5128 256 9 8.31 19 4.21 1,920 2 100 50 50 50 25 25128 272 9 8.31 20 6.70 2,040 2 107 53.5 53.5 54 27 27128 288 9 8.31 21 9.19 2,160 2 113 56.5 56.5 57 28.5 28.5128 304 9 8.31 22 11.68 2,280 2 119 59.5 59.5 60 30 30128 320 9 8.31 24 2.16 2,400 2 124 62 62 62 31 31128 336 9 8.31 25 4.65 2,520 2 132 66 66 66 33 33128 352 9 8.31 26 7.14 2,640 2 138 69 69 69 34.5 34.5128 368 9 8.31 27 9.63 2,760 2 143 71.5 71.5 72 36 36128 384 9 8.31 28 12.12 2,880 2 149 74.5 74.5 75 37.5 37.5128 400 9 8.31 30 2.60 3,000 2 157 78.5 78.5 79 39.5 39.5128 416 9 8.31 31 5.09 3,120 2 162 81 81 81 40.5 40.5128 432 9 8.31 32 7.58 3,240 2 168 84 84 84 42 42128 448 9 8.31 33 10.07 3,360 2 174 87 87 87 43.5 43.5128 464 9 8.31 35 0.56 3,480 2 — — — 91 45.5 45.5128 480 9 8.31 36 3.05 3,600 2 — — — 94 47 47128 496 9 8.31 37 5.53 3,720 2 — — — 97 48.5 48.5128 512 9 8.31 38 8.02 3,840 2 — — — 100 50 50128 528 9 8.31 39 10.51 3,960 2 — — — 103 51.5 51.5128 544 9 8.31 41 1.00 4,080 2 — — — 106 53 53128 560 9 8.31 42 3.49 4,200 2 — — — 109 54.5 54.5128 576 9 8.31 43 5.97 4,320 2 — — — 112 56 56128 592 9 8.31 44 8.46 4,440 2 — — — 116 58 58128 608 9 8.31 45 10.95 4,560 2 — — — 119 59.5 59.5128 624 9 8.31 47 1.44 4,680 2 — — — 121 60.5 60.5128 640 9 8.31 48 3.93 4,800 2 — — — 124 62 62144 48 10 10.79 3 7.86 405 2 22 12.22 9.78 11 6.11 4.89144 64 10 10.79 4 10.35 540 2 28 15.56 12.44 14 7.78 6.22144 96 10 10.79 7 3.33 810 2 43 23.89 19.11 22 12.22 9.78144 112 10 10.79 8 5.82 945 2 50 27.78 22.22 25 13.89 11.11144 128 10 10.79 9 8.31 1,080 2 56 31.11 24.89 28 15.56 12.44144 144 10 10.79 10 10.79 1,215 2 65 36.11 28.89 33 18.33 14.67144 160 10 10.79 12 1.28 1,350 2 71 39.44 31.56 36 20.00 16.00144 176 10 10.79 13 3.77 1,485 2 78 43.33 34.67 39 21.67 17.33144 192 10 10.79 14 6.26 1,620 2 84 46.67 37.33 42 23.33 18.67144 208 10 10.79 15 8.75 1,755 2 93 51.67 41.33 47 26.11 20.89144 224 10 10.79 16 11.23 1,890 2 99 55.00 44.00 50 27.78 22.22144 240 10 10.79 18 1.72 2,025 2 106 58.89 47.11 53 29.44 23.56144 256 10 10.79 19 4.21 2,160 2 112 62.22 49.78 56 31.11 24.89144 272 10 10.79 20 6.70 2,295 2 121 67.22 53.78 61 33.89 27.11144 288 10 10.79 21 9.19 2,430 2 127 70.56 56.44 64 35.56 28.44144 304 10 10.79 22 11.68 2,565 2 133 73.89 59.11 67 37.22 29.78144 320 10 10.79 24 2.16 2,700 2 140 77.78 62.22 70 38.89 31.11144 336 10 10.79 25 4.65 2,835 2 148 82.22 65.78 74 41.11 32.89144 352 10 10.79 26 7.14 2,970 2 155 86.11 68.89 78 43.33 34.67144 368 10 10.79 27 9.63 3,105 2 161 89.44 71.56 81 45.00 36.00144 384 10 10.79 28 12.12 3,240 2 168 93.33 74.67 84 46.67 37.33144 400 10 10.79 30 2.60 3,375 2 176 97.78 78.22 88 48.89 39.11144 416 10 10.79 31 5.09 3,510 2 183 101.67 81.33 92 51.11 40.89

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 80: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

78 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

144 432 10 10.79 32 7.58 3,645 2 189 105.00 84.00 95 52.78 42.22144 448 10 10.79 33 10.07 3,780 2 196 108.89 87.11 98 54.44 43.56144 464 10 10.79 35 0.56 3,915 2 — — — 102 56.67 45.33144 480 10 10.79 36 3.05 4,050 2 — — — 106 58.89 47.11144 496 10 10.79 37 5.53 4,185 2 — — — 109 60.56 48.44144 512 10 10.79 38 8.02 4,320 2 — — — 112 62.22 49.78144 528 10 10.79 39 10.51 4,455 2 — — — 116 64.44 51.56144 544 10 10.79 41 1.00 4,590 2 — — — 119 66.11 52.89144 560 10 10.79 42 3.49 4,725 2 — — — 123 68.33 54.67144 576 10 10.79 43 5.97 4,860 2 — — — 126 70.00 56.00144 592 10 10.79 44 8.46 4,995 2 — — — 130 72.22 57.78144 608 10 10.79 45 10.95 5,130 2 — — — 133 73.89 59.11144 624 10 10.79 47 1.44 5,265 2 — — — 137 76.11 60.89144 640 10 10.79 48 3.93 5,400 2 — — — 140 77.78 62.22160 48 12 1.28 3 7.86 450 2 24 12 12 12 6 6160 64 12 1.28 4 10.35 600 2 31 15.5 15.5 16 8 8160 96 12 1.28 7 3.33 900 2 48 24 24 24 12 12160 112 12 1.28 8 5.82 1,050 2 55 27.5 27.5 28 14 14160 128 12 1.28 9 8.31 1,200 2 62 31 31 31 15.5 15.5160 144 12 1.28 10 10.79 1,350 2 72 36 36 36 18 18160 160 12 1.28 12 1.28 1,500 2 79 39.5 39.5 40 20 20160 176 12 1.28 13 3.77 1,650 2 86 43 43 43 21.5 21.5160 192 12 1.28 14 6.26 1,800 2 93 46.5 46.5 47 23.5 23.5160 208 12 1.28 15 8.75 1,950 2 103 51.5 51.5 52 26 26160 224 12 1.28 16 11.23 2,100 2 110 55 55 55 27.5 27.5160 240 12 1.28 18 1.72 2,250 2 117 58.5 58.5 59 29.5 29.5160 256 12 1.28 19 4.21 2,400 2 124 62 62 62 31 31160 272 12 1.28 20 6.70 2,550 2 134 67 67 67 33.5 33.5160 288 12 1.28 21 9.19 2,700 2 141 70.5 70.5 71 35.5 35.5160 304 12 1.28 22 11.68 2,850 2 148 74 74 74 37 37160 320 12 1.28 24 2.16 3,000 2 155 77.5 77.5 78 39 39160 336 12 1.28 25 4.65 3,150 2 165 82.5 82.5 83 41.5 41.5160 352 12 1.28 26 7.14 3,300 2 172 86 86 86 43 43160 368 12 1.28 27 9.63 3,450 2 179 89.5 89.5 90 45 45160 384 12 1.28 28 12.12 3,600 2 186 93 93 93 46.5 46.5160 400 12 1.28 30 2.60 3,750 2 196 98 98 98 49 49160 416 12 1.28 31 5.09 3,900 2 203 101.5 101.5 102 51 51160 432 12 1.28 32 7.58 4,050 2 210 105 105 105 52.5 52.5160 448 12 1.28 33 10.07 4,200 2 217 108.5 108.5 109 54.5 54.5160 464 12 1.28 35 0.56 4,350 2 — — — 114 57 57160 480 12 1.28 36 3.05 4,500 2 — — — 117 58.5 58.5160 496 12 1.28 37 5.53 4,650 2 — — — 121 60.5 60.5160 512 12 1.28 38 8.02 4,800 2 — — — 124 62 62160 528 12 1.28 39 10.51 4,950 2 — — — 129 64.5 64.5160 544 12 1.28 41 1.00 5,100 2 — — — 133 66.5 66.5160 560 12 1.28 42 3.49 5,250 2 — — — 136 68 68160 576 12 1.28 43 5.97 5,400 2 — — — 140 70 70160 592 12 1.28 44 8.46 5,550 2 — — — 145 72.5 72.5160 608 12 1.28 45 10.95 5,700 2 — — — 148 74 74160 624 12 1.28 47 1.44 5,850 2 — — — 152 76 76160 640 12 1.28 48 3.93 6,000 2 — — — 155 77.5 77.5176 48 13 3.77 3 7.86 495 2 27 14.73 12.27 14 7.64 6.36176 64 13 3.77 4 10.35 660 2 35 19.09 15.91 18 9.82 8.18176 96 13 3.77 7 3.33 990 2 53 28.91 24.09 27 14.73 12.27

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 81: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 79

176 112 13 3.77 8 5.82 1,155 2 61 33.27 27.73 31 16.91 14.09176 128 13 3.77 9 8.31 1,320 2 69 37.64 31.36 35 19.09 15.91176 144 13 3.77 10 10.79 1,485 2 79 43.09 35.91 40 21.82 18.18176 160 13 3.77 12 1.28 1,650 2 87 47.45 39.55 44 24.00 20.00176 176 13 3.77 13 3.77 1,815 2 95 51.82 43.18 48 26.18 21.82176 192 13 3.77 14 6.26 1,980 2 103 56.18 46.82 52 28.36 23.64176 208 13 3.77 15 8.75 2,145 2 113 61.64 51.36 57 31.09 25.91176 224 13 3.77 16 11.23 2,310 2 121 66.00 55.00 61 33.27 27.73176 240 13 3.77 18 1.72 2,475 2 129 70.36 58.64 65 35.45 29.55176 256 13 3.77 19 4.21 2,640 2 137 74.73 62.27 69 37.64 31.36176 272 13 3.77 20 6.70 2,805 2 147 80.18 66.82 74 40.36 33.64176 288 13 3.77 21 9.19 2,970 2 155 84.55 70.45 78 42.55 35.45176 304 13 3.77 22 11.68 3,135 2 163 88.91 74.09 82 44.73 37.27176 320 13 3.77 24 2.16 3,300 2 171 93.27 77.73 86 46.91 39.09176 336 13 3.77 25 4.65 3,465 2 181 98.73 82.27 91 49.64 41.36176 352 13 3.77 26 7.14 3,630 2 189 103.09 85.91 95 51.82 43.18176 368 13 3.77 27 9.63 3,795 2 197 107.45 89.55 99 54.00 45.00176 384 13 3.77 28 12.12 3,960 2 205 111.82 93.18 103 56.18 46.82176 400 13 3.77 30 2.60 4,125 2 215 117.27 97.73 108 58.91 49.09176 416 13 3.77 31 5.09 4,290 2 223 121.64 101.36 112 61.09 50.91176 432 13 3.77 32 7.58 4,455 2 231 126.00 105.00 116 63.27 52.73176 448 13 3.77 33 10.07 4,620 2 239 130.36 108.64 120 65.45 54.55176 464 13 3.77 35 0.56 4,785 2 — — — 125 68.18 56.82176 480 13 3.77 36 3.05 4,950 2 — — — 129 70.36 58.64176 496 13 3.77 37 5.53 5,115 2 — — — 133 72.55 60.45176 512 13 3.77 38 8.02 5,280 2 — — — 137 74.73 62.27176 528 13 3.77 39 10.51 5,445 2 — — — 142 77.45 64.55176 544 13 3.77 41 1.00 5,610 2 — — — 146 79.64 66.36176 560 13 3.77 42 3.49 5,775 2 — — — 150 81.82 68.18176 576 13 3.77 43 5.97 5,940 2 — — — 154 84.00 70.00176 592 13 3.77 44 8.46 6,105 2 — — — 159 86.73 72.27176 608 13 3.77 45 10.95 6,270 2 — — — 163 88.91 74.09176 624 13 3.77 47 1.44 6,435 2 — — — 167 91.09 75.91176 640 13 3.77 48 3.93 6600 2 — — — 171 93.27 77.73192 48 14 6.26 3 7.86 540 2 29 14.5 14.5 15 7.5 7.5192 64 14 6.26 4 10.35 720 2 38 19 19 19 9.5 9.5192 96 14 6.26 7 3.33 1,080 2 58 29 29 29 14.5 14.5192 112 14 6.26 8 5.82 1,260 2 66 33 33 33 16.5 16.5192 128 14 6.26 9 8.31 1,440 2 75 37.5 37.5 38 19 19192 144 14 6.26 10 10.79 1,620 2 86 43 43 43 21.5 21.5192 160 14 6.26 12 1.28 1,800 2 95 47.5 47.5 48 24 24192 176 14 6.26 13 3.77 1,980 2 103 51.5 51.5 52 26 26192 192 14 6.26 14 6.26 2,160 2 112 56 56 56 28 28192 208 14 6.26 15 8.75 2,340 2 123 61.5 61.5 62 31 31192 224 14 6.26 16 11.23 2,520 2 132 66 66 66 33 33192 240 14 6.26 18 1.72 2,700 2 141 70.5 70.5 71 35.5 35.5192 256 14 6.26 19 4.21 2,880 2 149 74.5 74.5 75 37.5 37.5192 272 14 6.26 20 6.70 3,060 2 161 80.5 80.5 81 40.5 40.5192 288 14 6.26 21 9.19 3,240 2 169 84.5 84.5 85 42.5 42.5192 304 14 6.26 22 11.68 3,420 2 178 89 89 89 44.5 44.5192 320 14 6.26 24 2.16 3,600 2 186 93 93 93 46.5 46.5192 336 14 6.26 25 4.65 3,780 2 198 99 99 99 49.5 49.5192 352 14 6.26 26 7.14 3,960 2 206 103 103 103 51.5 51.5192 368 14 6.26 27 9.63 4,140 2 215 107.5 107.5 108 54 54

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 82: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

80 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

192 384 14 6.26 28 12.12 4,320 2 223 111.5 111.5 112 56 56192 400 14 6.26 30 2.60 4,500 2 235 117.5 117.5 118 59 59192 416 14 6.26 31 5.09 4,680 2 243 121.5 121.5 122 61 61192 432 14 6.26 32 7.58 4,860 2 252 126 126 126 63 63192 448 14 6.26 33 10.07 5,040 2 261 130.5 130.5 131 65.5 65.5192 464 14 6.26 35 0.56 5,220 2 — — — 136 68 68192 480 14 6.26 36 3.05 5,400 2 — — — 141 70.5 70.5192 496 14 6.26 37 5.53 5,580 2 — — — 145 72.5 72.5192 512 14 6.26 38 8.02 5,760 2 — — — 149 74.5 74.5192 528 14 6.26 39 10.51 5,940 2 — — — 155 77.5 77.5192 544 14 6.26 41 1.00 6,120 2 — — — 159 79.5 79.5192 560 14 6.26 42 3.49 6,300 2 — — — 163 81.5 81.5192 576 14 6.26 43 5.97 6,480 2 — — — 168 84 84192 592 14 6.26 44 8.46 6,660 2 — — — 173 86.5 86.5192 608 14 6.26 45 10.95 6,840 2 — — — 178 89 89192 624 14 6.26 47 1.44 7,020 2 — — — 182 91 91192 640 14 6.26 48 3.93 7,200 2 — — — 186 93 93

Excite 23mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC

current REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Total AC current REQ

(Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Page 83: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 81

Excite 35mm pitch sign specificationsAll Excite 35mm pitch signs are 10.145 inches in depth from the front of the display to the back of the steel mounting angle.

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

8 48 0 11.42 5 6.54 51 1 3 3 — — 1 1 — —8 64 0 11.42 7 4.59 68 1 4 4 — — 2 2 — —8 80 0 11.42 9 2.64 85 1 5 5 — — 2 2 — —8 96 0 11.42 11 0.68 102 1 6 6 — — 3 3 — —8 112 0 11.42 12 10.73 119 1 6 6 — — 3 3 — —8 128 0 11.42 14 8.78 136 1 7 7 — — 4 4 — —8 144 0 11.42 16 6.83 153 1 8 8 — — 4 4 — —8 160 0 11.42 18 4.87 170 1 9 9 — — 5 5 — —8 176 0 11.42 20 2.92 187 1 10 10 — — 5 5 — —8 192 0 11.42 22 0.97 204 1 11 11 — — 6 6 — —8 208 0 11.42 23 11.01 221 1 12 12 — — 6 6 — —8 224 0 11.42 25 9.06 238 1 13 13 — — 6 6 — —8 240 0 11.42 27 7.11 255 1 14 14 — — 7 7 — —8 256 0 11.42 29 5.16 272 1 15 15 — — 7 7 — —8 272 0 11.42 31 3.20 289 1 16 16 — — 8 8 — —8 288 0 11.42 33 1.25 306 1 17 17 — — 8 8 — —8 304 0 11.42 34 11.30 323 1 18 18 — — 9 9 — —8 320 0 11.42 36 9.34 340 1 19 19 — — 9 9 — —8 336 0 11.42 38 7.39 357 1 19 19 — — 10 10 — —8 352 0 11.42 40 5.44 374 1 20 20 — — 10 10 — —8 368 0 11.42 42 3.49 391 1 21 21 — — 11 11 — —8 384 0 11.42 44 1.53 408 1 22 22 — — 11 11 — —8 400 0 11.42 45 11.58 425 1 23 23 — — 12 12 — —8 416 0 11.42 47 9.63 442 1 24 24 — — 12 12 — —

16 48 1 10.45 5 6.54 102 1 6 6 — — 3 3 — —16 64 1 10.45 7 4.59 136 1 7 7 — — 4 4 — —16 80 1 10.45 9 2.64 170 1 9 9 — — 5 5 — —16 96 1 10.45 11 0.68 204 1 11 11 — — 6 6 — —16 112 1 10.45 12 10.73 238 1 13 13 — — 6 6 — —16 128 1 10.45 14 8.78 272 1 15 15 — — 7 7 — —16 144 1 10.45 16 6.83 306 1 17 17 — — 8 8 — —16 160 1 10.45 18 4.87 340 1 19 19 — — 9 9 — —16 176 1 10.45 20 2.92 374 1 20 20 — — 10 10 — —16 192 1 10.45 22 0.97 408 1 22 22 — — 11 11 — —16 208 1 10.45 23 11.01 442 1 24 24 — — 12 12 — —16 224 1 10.45 25 9.06 476 1 26 26 — — 13 13 — —16 240 1 10.45 27 7.11 510 1 28 28 — — 14 14 — —16 256 1 10.45 29 5.16 544 1 30 30 — — 15 15 — —16 272 1 10.45 31 3.20 578 1 31 31 — — 16 16 — —16 288 1 10.45 33 1.25 612 1 33 33 — — 17 17 — —16 304 1 10.45 34 11.30 646 1 35 35 — — 18 18 — —16 320 1 10.45 36 9.34 680 1 37 37 — — 19 19 — —16 336 1 10.45 38 7.39 714 1 39 39 — — 19 19 — —16 352 1 10.45 40 5.44 748 1 41 41 — — 20 20 — —16 368 1 10.45 42 3.49 782 1 43 43 — — 21 21 — —16 384 1 10.45 44 1.53 816 1 44 44 — — 22 22 — —16 400 1 10.45 45 11.58 850 1 46 46 — — 23 23 — —16 416 1 10.45 47 9.63 884 1 48 48 — — 24 24 — —24 48 2 9.47 5 6.54 153 1 8 8 — — 4 4 — —

Page 84: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

82 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

24 64 2 9.47 7 4.59 204 1 11 11 — — 6 6 — —24 80 2 9.47 9 2.64 255 1 14 14 — — 7 7 — —24 96 2 9.47 11 0.68 306 1 17 17 — — 8 8 — —24 112 2 9.47 12 10.73 357 1 19 19 — — 10 10 — —24 128 2 9.47 14 8.78 408 1 22 22 — — 11 11 — —24 144 2 9.47 16 6.83 459 1 25 25 — — 12 12 — —24 160 2 9.47 18 4.87 510 1 28 28 — — 14 14 — —24 176 2 9.47 20 2.92 561 1 31 31 — — 15 15 — —24 192 2 9.47 22 0.97 612 1 33 33 — — 17 17 — —24 208 2 9.47 23 11.01 663 1 36 36 — — 18 18 — —24 224 2 9.47 25 9.06 714 1 39 39 — — 19 19 — —24 240 2 9.47 27 7.11 765 1 42 42 — — 21 21 — —24 256 2 9.47 29 5.16 816 1 44 44 — — 22 22 — —24 272 2 9.47 31 3.20 867 1 47 47 — — 24 24 — —24 288 2 9.47 33 1.25 918 1 50 50 — — 25 25 — —24 304 2 9.47 34 11.30 969 1 53 53 — — 26 26 — —24 320 2 9.47 36 9.34 1020 1 56 56 — — 28 28 — —24 336 2 9.47 38 7.39 1071 1 58 58 — — 29 29 — —24 352 2 9.47 40 5.44 1122 1 61 61 — — 31 31 — —24 368 2 9.47 42 3.49 1173 1 64 64 — — 32 32 — —24 384 2 9.47 44 1.53 1224 1 67 67 — — 33 33 — —24 400 2 9.47 45 11.58 1275 1 69 69 — — 35 35 — —24 416 2 9.47 47 9.63 1326 1 72 72 — — 36 36 — —32 48 3 8.49 5 6.54 204 1 11 11 — — 6 6 — —32 64 3 8.49 7 4.59 272 1 15 15 — — 7 7 — —32 80 3 8.49 9 2.64 340 1 19 19 — — 9 9 — —32 96 3 8.49 11 0.68 408 1 22 22 — — 11 11 — —32 112 3 8.49 12 10.73 476 1 26 26 — — 13 13 — —32 128 3 8.49 14 8.78 544 1 30 30 — — 15 15 — —32 144 3 8.49 16 6.83 612 1 33 33 — — 17 17 — —32 160 3 8.49 18 4.87 680 1 37 37 — — 19 19 — —32 176 3 8.49 20 2.92 748 1 41 41 — — 20 20 — —32 192 3 8.49 22 0.97 816 1 44 44 — — 22 22 — —32 208 3 8.49 23 11.01 884 1 48 48 — — 24 24 — —32 224 3 8.49 25 9.06 952 1 52 52 — — 26 26 — —32 240 3 8.49 27 7.11 1020 1 56 56 — — 28 28 — —32 256 3 8.49 29 5.16 1088 1 59 59 — — 30 30 — —32 272 3 8.49 31 3.20 1156 1 63 63 — — 31 31 — —32 288 3 8.49 33 1.25 1224 1 67 67 — — 33 33 — —32 304 3 8.49 34 11.30 1292 1 70 70 — — 35 35 — —32 320 3 8.49 36 9.34 1360 1 74 74 — — 37 37 — —32 336 3 8.49 38 7.39 1428 1 78 78 — — 39 39 — —32 352 3 8.49 40 5.44 1496 1 81 81 — — 41 41 — —32 368 3 8.49 42 3.49 1564 1 85 85 — — 43 43 — —32 384 3 8.49 44 1.53 1632 1 89 89 — — 44 44 — —32 400 3 8.49 45 11.58 1700 1 93 93 — — 46 46 — —32 416 3 8.49 47 9.63 1768 1 96 96 — — 48 48 — —40 48 4 7.52 5 6.54 255 1 14 14 — — 7 7 — —40 64 4 7.52 7 4.59 340 1 19 19 — — 9 9 — —40 80 4 7.52 9 2.64 425 1 23 23 — — 12 12 — —40 96 4 7.52 11 0.68 510 1 28 28 — — 14 14 — —40 112 4 7.52 12 10.73 595 1 32 32 — — 16 16 — —40 128 4 7.52 14 8.78 680 1 37 37 — — 19 19 — —40 144 4 7.52 16 6.83 765 1 42 42 — — 21 21 — —

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 85: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 83

40 160 4 7.52 18 4.87 850 1 46 46 — — 23 23 — —40 176 4 7.52 20 2.92 935 1 51 51 — — 25 25 — —40 192 4 7.52 22 0.97 1020 1 56 56 — — 28 28 — —40 208 4 7.52 23 11.01 1105 1 60 60 — — 30 30 — —40 224 4 7.52 25 9.06 1190 1 65 65 — — 32 32 — —40 240 4 7.52 27 7.11 1275 1 69 69 — — 35 35 — —40 256 4 7.52 29 5.16 1360 1 74 74 — — 37 37 — —40 272 4 7.52 31 3.20 1445 1 79 79 — — 39 39 — —40 288 4 7.52 33 1.25 1530 1 83 83 — — 42 42 — —40 304 4 7.52 34 11.30 1615 1 88 88 — — 44 44 — —40 320 4 7.52 36 9.34 1700 1 93 93 — — 46 46 — —40 336 4 7.52 38 7.39 1785 1 97 97 — — 49 49 — —40 352 4 7.52 40 5.44 1870 1 102 102 — — 51 51 — —40 368 4 7.52 42 3.49 1955 1 106 106 — — 53 53 — —40 384 4 7.52 44 1.53 2040 1 111 111 — — 56 56 — —40 400 4 7.52 45 11.58 2125 1 116 116 — — 58 58 — —40 416 4 7.52 47 9.63 2210 1 120 120 — — 60 60 — —48 48 5 6.54 5 6.54 306 1 17 17 — — 8 8 — —48 64 5 6.54 7 4.59 408 1 22 22 — — 11 11 — —48 80 5 6.54 9 2.64 510 1 28 28 — — 14 14 — —48 96 5 6.54 11 0.68 612 1 33 33 — — 17 17 — —48 112 5 6.54 12 10.73 714 1 39 39 — — 19 19 — —48 128 5 6.54 14 8.78 816 1 44 44 — — 22 22 — —48 144 5 6.54 16 6.83 918 1 50 50 — — 25 25 — —48 160 5 6.54 18 4.87 1020 1 56 56 — — 28 28 — —48 176 5 6.54 20 2.92 1122 1 61 61 — — 31 31 — —48 192 5 6.54 22 0.97 1224 1 67 67 — — 33 33 — —48 208 5 6.54 23 11.01 1326 1 72 72 — — 36 36 — —48 224 5 6.54 25 9.06 1428 1 78 78 — — 39 39 — —48 240 5 6.54 27 7.11 1530 1 83 83 — — 42 42 — —48 256 5 6.54 29 5.16 1632 1 89 89 — — 44 44 — —48 272 5 6.54 31 3.20 1734 1 94 94 — — 47 47 — —48 288 5 6.54 33 1.25 1836 1 100 100 — — 50 50 — —48 304 5 6.54 34 11.30 1938 1 105 105 — — 53 53 — —48 320 5 6.54 36 9.34 2040 1 111 111 — — 56 56 — —48 336 5 6.54 38 7.39 2142 1 117 117 — — 58 58 — —48 352 5 6.54 40 5.44 2244 1 122 122 — — 61 61 — —48 368 5 6.54 42 3.49 2346 1 128 128 — — 64 64 — —48 384 5 6.54 44 1.53 2448 1 133 133 — — 67 67 — —48 400 5 6.54 45 11.58 2550 1 139 139 — — 69 69 — —48 416 5 6.54 47 9.63 2652 1 144 144 — — 72 72 — —56 48 6 5.57 5 6.54 357 2 19 17 3 — 10 8 1 —56 64 6 5.57 7 4.59 476 2 26 22 4 — 13 11 2 —56 80 6 5.57 9 2.64 595 2 32 28 5 — 16 14 2 —56 96 6 5.57 11 0.68 714 2 39 33 6 — 19 17 3 —56 112 6 5.57 12 10.73 833 2 45 39 6 — 23 19 3 —56 128 6 5.57 14 8.78 952 2 52 44 7 — 26 22 4 —56 144 6 5.57 16 6.83 1071 2 58 50 8 — 29 25 4 —56 160 6 5.57 18 4.87 1190 2 65 56 9 — 32 28 5 —56 176 6 5.57 20 2.92 1309 2 71 61 10 — 36 31 5 —56 192 6 5.57 22 0.97 1428 2 78 67 11 — 39 33 6 —56 208 6 5.57 23 11.01 1547 2 84 72 12 — 42 36 6 —56 224 6 5.57 25 9.06 1666 2 91 78 13 — 45 39 6 —56 240 6 5.57 27 7.11 1785 2 97 83 14 — 49 42 7 —

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 86: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

84 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

56 256 6 5.57 29 5.16 1904 2 104 89 15 — 52 44 7 —56 272 6 5.57 31 3.20 2023 2 110 94 16 — 55 47 8 —56 288 6 5.57 33 1.25 2142 2 117 100 17 — 58 50 8 —56 304 6 5.57 34 11.30 2261 2 123 105 18 — 62 53 9 —56 320 6 5.57 36 9.34 2380 2 130 111 19 — 65 56 9 —56 336 6 5.57 38 7.39 2499 2 136 117 19 — 68 58 10 —56 352 6 5.57 40 5.44 2618 2 142 122 20 — 71 61 10 —56 368 6 5.57 42 3.49 2737 2 149 128 21 — 74 64 11 —56 384 6 5.57 44 1.53 2856 2 155 133 22 — 78 67 11 —56 400 6 5.57 45 11.58 2975 2 162 139 23 — 81 69 12 —56 416 6 5.57 47 9.63 3094 2 168 144 24 — 84 72 12 —64 48 7 4.59 5 6.54 408 2 22 17 6 — 11 8 3 —64 64 7 4.59 7 4.59 544 2 30 22 7 — 15 11 4 —64 80 7 4.59 9 2.64 680 2 37 28 9 — 19 14 5 —64 96 7 4.59 11 0.68 816 2 44 33 11 — 22 17 6 —64 112 7 4.59 12 10.73 952 2 52 39 13 — 26 19 6 —64 128 7 4.59 14 8.78 1088 2 59 44 15 — 30 22 7 —64 144 7 4.59 16 6.83 1224 2 67 50 17 — 33 25 8 —64 160 7 4.59 18 4.87 1360 2 74 56 19 — 37 28 9 —64 176 7 4.59 20 2.92 1496 2 81 61 20 — 41 31 10 —64 192 7 4.59 22 0.97 1632 2 89 67 22 — 44 33 11 —64 208 7 4.59 23 11.01 1768 2 96 72 24 — 48 36 12 —64 224 7 4.59 25 9.06 1904 2 104 78 26 — 52 39 13 —64 240 7 4.59 27 7.11 2040 2 111 83 28 — 56 42 14 —64 256 7 4.59 29 5.16 2176 2 118 89 30 — 59 44 15 —64 272 7 4.59 31 3.20 2312 2 126 94 31 — 63 47 16 —64 288 7 4.59 33 1.25 2448 2 133 100 33 — 67 50 17 —64 304 7 4.59 34 11.30 2584 2 141 105 35 — 70 53 18 —64 320 7 4.59 36 9.34 2720 2 148 111 37 — 74 56 19 —64 336 7 4.59 38 7.39 2856 2 155 117 39 — 78 58 19 —64 352 7 4.59 40 5.44 2992 2 163 122 41 — 81 61 20 —64 368 7 4.59 42 3.49 3128 2 170 128 43 — 85 64 21 —64 384 7 4.59 44 1.53 3264 2 178 133 44 — 89 67 22 —64 400 7 4.59 45 11.58 3400 2 185 139 46 — 93 69 23 —64 416 7 4.59 47 9.63 3536 2 192 144 48 — 96 72 24 —72 48 8 3.61 5 6.54 459 2 25 17 8 — 12 8 4 —72 64 8 3.61 7 4.59 612 2 33 22 11 — 17 11 6 —72 80 8 3.61 9 2.64 765 2 42 28 14 — 21 14 7 —72 96 8 3.61 11 0.68 918 2 50 33 17 — 25 17 8 —72 112 8 3.61 12 10.73 1071 2 58 39 19 — 29 19 10 —72 128 8 3.61 14 8.78 1224 2 67 44 22 — 33 22 11 —72 144 8 3.61 16 6.83 1377 2 75 50 25 — 37 25 12 —72 160 8 3.61 18 4.87 1530 2 83 56 28 — 42 28 14 —72 176 8 3.61 20 2.92 1683 2 92 61 31 — 46 31 15 —72 192 8 3.61 22 0.97 1836 2 100 67 33 — 50 33 17 —72 208 8 3.61 23 11.01 1989 2 108 72 36 — 54 36 18 —72 224 8 3.61 25 9.06 2142 2 117 78 39 — 58 39 19 —72 240 8 3.61 27 7.11 2295 2 125 83 42 — 62 42 21 —72 256 8 3.61 29 5.16 2448 2 133 89 44 — 67 44 22 —72 272 8 3.61 31 3.20 2601 2 142 94 47 — 71 47 24 —72 288 8 3.61 33 1.25 2754 2 150 100 50 — 75 50 25 —72 304 8 3.61 34 11.30 2907 2 158 105 53 — 79 53 26 —72 320 8 3.61 36 9.34 3060 2 167 111 56 — 83 56 28 —72 336 8 3.61 38 7.39 3213 2 175 117 58 — 87 58 29 —

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 87: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 85

72 352 8 3.61 40 5.44 3366 2 183 122 61 — 92 61 31 —72 368 8 3.61 42 3.49 3519 2 191 128 64 — 96 64 32 —72 384 8 3.61 44 1.53 3672 2 200 133 67 — 100 67 33 —72 400 8 3.61 45 11.58 3825 2 208 139 69 — 104 69 35 —72 416 8 3.61 47 9.63 3978 2 216 144 72 — 108 72 36 —80 48 9 2.64 5 6.54 510 2 28 17 11 — 14 8 6 —80 64 9 2.64 7 4.59 680 2 37 22 15 — 19 11 7 —80 80 9 2.64 9 2.64 850 2 46 28 19 — 23 14 9 —80 96 9 2.64 11 0.68 1020 2 56 33 22 — 28 17 11 —80 112 9 2.64 12 10.73 1190 2 65 39 26 — 32 19 13 —80 128 9 2.64 14 8.78 1360 2 74 44 30 — 37 22 15 —80 144 9 2.64 16 6.83 1530 2 83 50 33 — 42 25 17 —80 160 9 2.64 18 4.87 1700 2 93 56 37 — 46 28 19 —80 176 9 2.64 20 2.92 1870 2 102 61 41 — 51 31 20 —80 192 9 2.64 22 0.97 2040 2 111 67 44 — 56 33 22 —80 208 9 2.64 23 11.01 2210 2 120 72 48 — 60 36 24 —80 224 9 2.64 25 9.06 2380 2 130 78 52 — 65 39 26 —80 240 9 2.64 27 7.11 2550 2 139 83 56 — 69 42 28 —80 256 9 2.64 29 5.16 2720 2 148 89 59 — 74 44 30 —80 272 9 2.64 31 3.20 2890 2 157 94 63 — 79 47 31 —80 288 9 2.64 33 1.25 3060 2 167 100 67 — 83 50 33 —80 304 9 2.64 34 11.30 3230 2 176 105 70 — 88 53 35 —80 320 9 2.64 36 9.34 3400 2 185 111 74 — 93 56 37 —80 336 9 2.64 38 7.39 3570 2 194 117 78 — 97 58 39 —80 352 9 2.64 40 5.44 3740 2 204 122 81 — 102 61 41 —80 368 9 2.64 42 3.49 3910 2 213 128 85 — 106 64 43 —80 384 9 2.64 44 1.53 4080 2 222 133 89 — 111 67 44 —80 400 9 2.64 45 11.58 4250 2 231 139 93 — 116 69 46 —80 416 9 2.64 47 9.63 4420 2 241 144 96 — 120 72 48 —88 48 10 1.66 5 6.54 561 2 31 17 14 — 15 8 7 —88 64 10 1.66 7 4.59 748 2 41 22 19 — 20 11 9 —88 80 10 1.66 9 2.64 935 2 51 28 23 — 25 14 12 —88 96 10 1.66 11 0.68 1122 2 61 33 28 — 31 17 14 —88 112 10 1.66 12 10.73 1309 2 71 39 32 — 36 19 16 —88 128 10 1.66 14 8.78 1496 2 81 44 37 — 41 22 19 —88 144 10 1.66 16 6.83 1683 2 92 50 42 — 46 25 21 —88 160 10 1.66 18 4.87 1870 2 102 56 46 — 51 28 23 —88 176 10 1.66 20 2.92 2057 2 112 61 51 — 56 31 25 —88 192 10 1.66 22 0.97 2244 2 122 67 56 — 61 33 28 —88 208 10 1.66 23 11.01 2431 2 132 72 60 — 66 36 30 —88 224 10 1.66 25 9.06 2618 2 142 78 65 — 71 39 32 —88 240 10 1.66 27 7.11 2805 2 153 83 69 — 76 42 35 —88 256 10 1.66 29 5.16 2992 2 163 89 74 — 81 44 37 —88 272 10 1.66 31 3.20 3179 2 173 94 79 — 86 47 39 —88 288 10 1.66 33 1.25 3366 2 183 100 83 — 92 50 42 —88 304 10 1.66 34 11.30 3553 2 193 105 88 — 97 53 44 —88 320 10 1.66 36 9.34 3740 2 204 111 93 — 102 56 46 —88 336 10 1.66 38 7.39 3927 2 214 117 97 — 107 58 49 —88 352 10 1.66 40 5.44 4114 2 224 122 102 — 112 61 51 —88 368 10 1.66 42 3.49 4301 2 234 128 106 — 117 64 53 —88 384 10 1.66 44 1.53 4488 2 244 133 111 — 122 67 56 —88 400 10 1.66 45 11.58 4675 2 254 139 116 — 127 69 58 —88 416 10 1.66 47 9.63 4862 2 265 144 120 — 132 72 60 —96 48 11 0.68 5 6.54 612 2 33 17 17 — 17 8 8 —

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 88: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

86 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

96 64 11 0.68 7 4.59 816 2 44 22 22 — 22 11 11 —96 80 11 0.68 9 2.64 1020 2 56 28 28 — 28 14 14 —96 96 11 0.68 11 0.68 1224 2 67 33 33 — 33 17 17 —96 112 11 0.68 12 10.73 1428 2 78 39 39 — 39 19 19 —96 128 11 0.68 14 8.78 1632 2 89 44 44 — 44 22 22 —96 144 11 0.68 16 6.83 1836 2 100 50 50 — 50 25 25 —96 160 11 0.68 18 4.87 2040 2 111 56 56 — 56 28 28 —96 176 11 0.68 20 2.92 2244 2 122 61 61 — 61 31 31 —96 192 11 0.68 22 0.97 2448 2 133 67 67 — 67 33 33 —96 208 11 0.68 23 11.01 2652 2 144 72 72 — 72 36 36 —96 224 11 0.68 25 9.06 2856 2 155 78 78 — 78 39 39 —96 240 11 0.68 27 7.11 3060 2 167 83 83 — 83 42 42 —96 256 11 0.68 29 5.16 3264 2 178 89 89 — 89 44 44 —96 272 11 0.68 31 3.20 3468 2 189 94 94 — 94 47 47 —96 288 11 0.68 33 1.25 3672 2 200 100 100 — 100 50 50 —96 304 11 0.68 34 11.30 3876 2 211 105 105 — 105 53 53 —96 320 11 0.68 36 9.34 4080 2 222 111 111 — 111 56 56 —96 336 11 0.68 38 7.39 4284 2 233 117 117 — 117 58 58 —96 352 11 0.68 40 5.44 4488 2 244 122 122 — 122 61 61 —96 368 11 0.68 42 3.49 4692 2 255 128 128 — 128 64 64 —96 384 11 0.68 44 1.53 4896 2 266 133 133 — 133 67 67 —96 400 11 0.68 45 11.58 5100 2 278 139 139 — 139 69 69 —96 416 11 0.68 47 9.63 5304 2 289 144 144 — 144 72 72 —104 48 11 11.71 5 6.54 663 3 36 17 17 3 18 8 8 1104 64 11 11.71 7 4.59 884 3 48 22 22 4 24 11 11 2104 80 11 11.71 9 2.64 1105 3 60 28 28 5 30 14 14 2104 96 11 11.71 11 0.68 1326 3 72 33 33 6 36 17 17 3104 112 11 11.71 12 10.73 1547 3 84 39 39 6 42 19 19 3104 128 11 11.71 14 8.78 1768 3 96 44 44 7 48 22 22 4104 144 11 11.71 16 6.83 1989 3 108 50 50 8 54 25 25 4104 160 11 11.71 18 4.87 2210 3 120 56 56 9 60 28 28 5104 176 11 11.71 20 2.92 2431 3 132 61 61 10 66 31 31 5104 192 11 11.71 22 0.97 2652 3 144 67 67 11 72 33 33 6104 208 11 11.71 23 11.01 2873 3 156 72 72 12 78 36 36 6104 224 11 11.71 25 9.06 3094 3 168 78 78 13 84 39 39 6104 240 11 11.71 27 7.11 3315 3 180 83 83 14 90 42 42 7104 256 11 11.71 29 5.16 3536 3 192 89 89 15 96 44 44 7104 272 11 11.71 31 3.20 3757 3 204 94 94 16 102 47 47 8104 288 11 11.71 33 1.25 3978 3 216 100 100 17 108 50 50 8104 304 11 11.71 34 11.30 4199 3 228 105 105 18 114 53 53 9104 320 11 11.71 36 9.34 4420 3 241 111 111 19 120 56 56 9104 336 11 11.71 38 7.39 4641 3 253 117 117 19 126 58 58 10104 352 11 11.71 40 5.44 4862 3 265 122 122 20 132 61 61 10104 368 11 11.71 42 3.49 5083 3 277 128 128 21 138 64 64 11104 384 11 11.71 44 1.53 5304 3 289 133 133 22 144 67 67 11104 400 11 11.71 45 11.58 5525 3 301 139 139 23 150 69 69 12104 416 11 11.71 47 9.63 5746 3 313 144 144 24 156 72 72 12112 48 12 10.73 5 6.54 714 3 39 17 17 6 19 8 8 3112 64 12 10.73 7 4.59 952 3 52 22 22 7 26 11 11 4112 80 12 10.73 9 2.64 1190 3 65 28 28 9 32 14 14 5112 96 12 10.73 11 0.68 1428 3 78 33 33 11 39 17 17 6112 112 12 10.73 12 10.73 1666 3 91 39 39 13 45 19 19 6112 128 12 10.73 14 8.78 1904 3 104 44 44 15 52 22 22 7112 144 12 10.73 16 6.83 2142 3 117 50 50 17 58 25 25 8

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 89: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 87

112 160 12 10.73 18 4.87 2380 3 130 56 56 19 65 28 28 9112 176 12 10.73 20 2.92 2618 3 142 61 61 20 71 31 31 10112 192 12 10.73 22 0.97 2856 3 155 67 67 22 78 33 33 11112 208 12 10.73 23 11.01 3094 3 168 72 72 24 84 36 36 12112 224 12 10.73 25 9.06 3332 3 181 78 78 26 91 39 39 13112 240 12 10.73 27 7.11 3570 3 194 83 83 28 97 42 42 14112 256 12 10.73 29 5.16 3808 3 207 89 89 30 104 44 44 15112 272 12 10.73 31 3.20 4046 3 220 94 94 31 110 47 47 16112 288 12 10.73 33 1.25 4284 3 233 100 100 33 117 50 50 17112 304 12 10.73 34 11.30 4522 3 246 105 105 35 123 53 53 18112 320 12 10.73 36 9.34 4760 3 259 111 111 37 130 56 56 19112 336 12 10.73 38 7.39 4998 3 272 117 117 39 136 58 58 19112 352 12 10.73 40 5.44 5236 3 285 122 122 41 142 61 61 20112 368 12 10.73 42 3.49 5474 3 298 128 128 43 149 64 64 21112 384 12 10.73 44 1.53 5712 3 311 133 133 44 155 67 67 22112 400 12 10.73 45 11.58 5950 3 324 139 139 46 162 69 69 23112 416 12 10.73 47 9.63 6188 3 337 144 144 48 168 72 72 24120 48 13 9.75 5 6.54 765 3 42 17 17 8 21 8 8 4120 64 13 9.75 7 4.59 1020 3 56 22 22 11 28 11 11 6120 80 13 9.75 9 2.64 1275 3 69 28 28 14 35 14 14 7120 96 13 9.75 11 0.68 1530 3 83 33 33 17 42 17 17 8120 112 13 9.75 12 10.73 1785 3 97 39 39 19 49 19 19 10120 128 13 9.75 14 8.78 2040 3 111 44 44 22 56 22 22 11120 144 13 9.75 16 6.83 2295 3 125 50 50 25 62 25 25 12120 160 13 9.75 18 4.87 2550 3 139 56 56 28 69 28 28 14120 176 13 9.75 20 2.92 2805 3 153 61 61 31 76 31 31 15120 192 13 9.75 22 0.97 3060 3 167 67 67 33 83 33 33 17120 208 13 9.75 23 11.01 3315 3 180 72 72 36 90 36 36 18120 224 13 9.75 25 9.06 3570 3 194 78 78 39 97 39 39 19120 240 13 9.75 27 7.11 3825 3 208 83 83 42 104 42 42 21120 256 13 9.75 29 5.16 4080 3 222 89 89 44 111 44 44 22120 272 13 9.75 31 3.20 4335 3 236 94 94 47 118 47 47 24120 288 13 9.75 33 1.25 4590 3 250 100 100 50 125 50 50 25120 304 13 9.75 34 11.30 4845 3 264 105 105 53 132 53 53 26120 320 13 9.75 36 9.34 5100 3 278 111 111 56 139 56 56 28120 336 13 9.75 38 7.39 5355 3 291 117 117 58 146 58 58 29120 352 13 9.75 40 5.44 5610 3 305 122 122 61 153 61 61 31120 368 13 9.75 42 3.49 5865 3 319 128 128 64 160 64 64 32120 384 13 9.75 44 1.53 6120 3 333 133 133 67 167 67 67 33120 400 13 9.75 45 11.58 6375 3 347 139 139 69 173 69 69 35120 416 13 9.75 47 9.63 6630 3 361 144 144 72 180 72 72 36128 48 14 8.78 5 6.54 816 3 44 17 17 11 22 8 8 6128 64 14 8.78 7 4.59 1088 3 59 22 22 15 30 11 11 7128 80 14 8.78 9 2.64 1360 3 74 28 28 19 37 14 14 9128 96 14 8.78 11 0.68 1632 3 89 33 33 22 44 17 17 11128 112 14 8.78 12 10.73 1904 3 104 39 39 26 52 19 19 13128 128 14 8.78 14 8.78 2176 3 118 44 44 30 59 22 22 15128 144 14 8.78 16 6.83 2448 3 133 50 50 33 67 25 25 17128 160 14 8.78 18 4.87 2720 3 148 56 56 37 74 28 28 19128 176 14 8.78 20 2.92 2992 3 163 61 61 41 81 31 31 20128 192 14 8.78 22 0.97 3264 3 178 67 67 44 89 33 33 22128 208 14 8.78 23 11.01 3536 3 192 72 72 48 96 36 36 24128 224 14 8.78 25 9.06 3808 3 207 78 78 52 104 39 39 26128 240 14 8.78 27 7.11 4080 3 222 83 83 56 111 42 42 28

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 90: Excite Installation Manual

APPENDIX TECHNICAL SPECIFICATIONS

88 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

128 256 14 8.78 29 5.16 4352 3 237 89 89 59 118 44 44 30128 272 14 8.78 31 3.20 4624 3 252 94 94 63 126 47 47 31128 288 14 8.78 33 1.25 4896 3 266 100 100 67 133 50 50 33128 304 14 8.78 34 11.30 5168 3 281 105 105 70 141 53 53 35128 320 14 8.78 36 9.34 5440 3 296 111 111 74 148 56 56 37128 336 14 8.78 38 7.39 5712 3 311 117 117 78 155 58 58 39128 352 14 8.78 40 5.44 5984 3 326 122 122 81 163 61 61 41128 368 14 8.78 42 3.49 6256 3 340 128 128 85 170 64 64 43128 384 14 8.78 44 1.53 6528 3 355 133 133 89 178 67 67 44128 400 14 8.78 45 11.58 6800 3 370 139 139 93 185 69 69 46128 416 14 8.78 47 9.63 7072 3 385 144 144 96 192 72 72 48

Excite 35mm Series B specifications

Rows Columns

Height Width

Weight (pounds)

Number of Power Entries

115VAC 230VAC

Ft In Ft InTotal AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Total AC current

REQ (Amp)

Power Entry A (Amp)

Power Entry B (Amp)

Power Entry C (Amp)

Page 91: Excite Installation Manual

APPENDIX VENTILATION DIAGRAM FOR BACK–TO–BACK SIGN CONFIGURATIONS

EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D) 89

Ventilation diagram for back–to–back sign configurations

Hotair

flow

Coolerair flow

ID SignHot air

flowHot air

flow

Air duct

Minimumclearance6-inches

Air duct

Monument

Coolerair flow

Air ductAir duct

ID Sign

Monument

ID Sign

Monument

Minimumclearance

1-inch

Minimumclearance

1-inch

Recommended method Clearance requirements

DO NOT allow water to poolunderneath the sign.DO NOT mount sign directlyon the base / floor.

DO NOT seal off air flow.

Follow these guidelines or sign warranty will be void:

DO NOT allow water from the aboveID sign, fascia trim, or flashing to dripdirectly onto the sign’s door seams orpool on top of the sign.

If the structure above the sign does notextend out past the sign’s door seams,install flashing to the structure.

Figure 69.Monument ventilation for back to back signs

Page 92: Excite Installation Manual

THIS PAGE INTENTIONALLY BLANK

90 EXCITE 16MM, 20MM, 23MM, AND 35MM PITCH SIGN INSTALLATION MANUAL (PN 1199613601 REV.D)

APPENDIX