exb17041 bornes vehicules electriques...which charging point at home? socket + bracket + rcbo (1) 3...
TRANSCRIPT
GREEN'UPYOUR ELECTRIC VEHICLE
CHARGING SOLUTIONSFOR ELECTRIC VEHICLESOR PLUG-IN HYBRIDS
THE GLOBAL SPECIALIST IN ELECTRICALAND DIGITAL BUILDING INFRASTRUCTURES
EXB17041_Bornes vehicules electriques.indd 1 21/12/2017 09:57
CHARGINGMODE CHARGING SOLUTIONS
MODE 18 A/10 A max.
(according to country)
Scooter, e-bike
MODE 2
Standardsocket
Standardsocket
Green'upsocket by
Legrand plug8 A/10 A max.
(according to country)
Electric car
Standard plug
Standard plug
Green'upsocket by
Legrand plug16 A max.
Electric car
MODE 3
3.7Premchar
7.4Premchar
Type 2S plug
Electric car
Type 2S plug
Electric car
11station
22Premchar
SIN
GLE
-PH
ASE
SIN
GLE
-PH
ASE
THR
EE-P
HAS
E
* Average charging time
Whichinfrastructure
for normal charging?
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 2 21/12/2017 09:57
33LUTIONS LEGRAND RECOMMENDATIONS CHARGING TIMEfor 100 km*
A/10 A max.ding to country) Non-dedicated conventional socket outlet.
NOT RECOMMENDED for electric vehicles X
Standardsocket
Standardsocket
Green'up Accesssocket by Legrand
Legrand plug
Standard plug
Standard plug
Standard plug + dedicated standard socketLimited charge circuitOCCASIONAL
6 hrs
Legrand safety plug + dedicated standard socketLimited charge circuitOCCASIONAL
6 hrs
Standard plug + Green'up Access socket by LegrandSafe dedicated accessLimited charge circuitPERMITTED
6 hrs
Green'up Accesssocket by Legrand
Legrand plug Legrand plug + Green'up Access socket by LegrandSafe, dedicated circuit, optimised chargingRECOMMENDED
3 hrs
3.7 kW Green’upPremiumcharging station
7.4 kW Green’upPremiumcharging station
Type 2S plug
Type 2S plugSafe, dedicated circuit, optimised chargingRECOMMENDED
3 hrs
1 hr 30
Type 2S plug 11 kW chargingstation
22 kW Green’upPremiumcharging station
1 hr
30 min
* Average charging time for a range of 100 km, based on average consumption of 12 kW/h per 100 km. Varies according to the electric car model
e
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 3 21/12/2017 09:57
Which charging pointat home?
SOCKET + BRACKET + RCBO
(1) 3 hrs with Legrand coupler, 6 hrs with non-Legrand couplerAverage charge for a range of 100 km, varies according to the model.
MODE 2
IP 66 - IK 0816 A - 3.7 kWsingle-phase
Supplied with bracketand RCBO
Charging time
“
6 hto
3 h(1)
4
(1) Average time for full charg
SOLUTION WHICOR REMOTELYThe Green’up PremWith its native BlueCHARGE application.(optional), it allows
GREEN’UP ACCESS READY TO INSTALL KIT
Heavy-duty socket, identifiedfor electric vehicles, alsosuitable for any applicationConforms to IEC 60884-1
WHEN I'M AT HOME,I CAN CHARGE MYELECTRIC VEHICLE INCOMPLETE SAFETY
8 to 16 A charging incomplete safety
of all electric vehicles witha mode 1 or mode 2 cable,
regardless of how muchcharging power is required
by the vehicle
Optimum safetySurface treatment of
metal contactsto improve electrical
conductivity
SOLUTION THAT IS INEXPENSIVE, ADAPTABLE AND SAFEWith the Green’up Access socket, Legrand makes it easy to charge vehicles at home. Inexpensive,simple to install, safe, they can also be used for all conventional purposes, and are speciallyprewired so they can easily be replaced with a mode 3 charging station.
Vehicles detect the secure Green’upinfrastructure and select themaximum power that can besupplied via the socket, resultingin a shorter charging time.
DETECTION SYSTEMPATENTED BY LEGRAND
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
GREEN’UP
Line protected byRCBO
EXB17041_Bornes vehicules electriques.indd 4 21/12/2017 09:58
55
point
MODE 2
IP 66 - IK 0816 A - 3.7 kWsingle-phase
Supplied with bracketand RCBO
Line protected byRCBO.
Wiring diagramp. 17
Charging time
6 hto
3 h(1)
(1) Average time for full charge according to manufacturer sources, varies according to the model
SOLUTION WHICH ALLOWS CHARGING TO BE CONTROLLED LOCALLYOR REMOTELYThe Green’up Premium charging station is used for charging vehicles in mode 2 and mode 3.With its native Bluetooth connection it can be used to control charging locally via the EVCHARGE application. When connected to the IP or Wi-Fi network with the communication kit(optional), it allows remote control from a smartphone, tablet computer or PC.
MODE 2
MODE 3COMMUNICATING
IP 44 - IK 083.7/7.4 kW/22 kWsingle-phase and
three-phase
MANAGING CHARGING1 STANDARD (USING BLUETOOTH
WITH EV CHARGE)- Peak/Off-peak hours override- Programmable daily charging and powe
management- Viewing consumption of the last charge- Software update2 WITH COMMUNICATION KIT (OPTIONAL)
- Remote control of charging- Weekly monitoring of consumption
(via Wi-Fi router or RJ 45)- Management via the EV CHARGE app
“THANKS TO THEEV CHARGE APP, I CANCONTROL CHARGINGFROM MY TABLETCOMPUTER, MYSMARTPHONEOR MY PC
Delayed start: 3, 6 or 9 hoursOption of delaying start by 3, 6 or9 hours. For charging during the
cheap rate period.
Volt-free contact inputFor external control of the charging station
(time switch, contactor, etc)
Single-phase Three-phase
Charging time
1 hto
30min(1)
3 hto
1h30(1)
HOME,CHARGE MY
EHICLE INSAFETY
8 to 16 A charging incomplete safety
l electric vehicles witha mode 1 or mode 2 cable,
gardless of how muchging power is required
by the vehicle
Optimum safetySurface treatment of
metal contactsto improve electrical
conductivity
For any electric vehicle modelGreen’up Access heavy-duty socket
for charging in mode 2 andfor all applications
For any electric vehicle modelShuttered T2S EV Plug socket
for mode 3 charging.
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
GREEN’UP PREMIUM CHARGING STATION
Line protected byRCBO
EXB17041_Bornes vehicules electriques.indd 5 21/12/2017 09:58
6SOCKET + BRACKET
(1) 3 hrs with Legrand coupler, 6 hrs with non-Legrand couplerAverage charge for a range of 100 km, varies according to the model.
RUGGED, INEXPENSIVE AND SCALABLE SOLUTION FOR EXPOSED LOCATIONSWith its IK 10 protection giving it excellent resistance to harsh environments, the Green’up Accesssocket is perfect for use in public car parks and lock-ups. Inexpensive, simple to install, safe, itcan also be used for all conventional purposes, and is specially prewired so it can easily bereplaced with a mode 3 charging station.
Which charging pointin collective housing
and private commercial sectorMODES 1 & 2
IP 55 - IK 1016 A - 3.7 kWsingle-phase
Charging time
I CAN PARTIALLYRECHARGE MY ELECTRICCAR IN A PUBLIC CARPARK WHILE HAVINGLUNCH WITH FRIENDS
“Flush mounting or surface
mounting with frame
6 hto
3 h(1)
Supplied with bracketAvailable withlockable flap
Line protected byRCBO.
Wiring diagramp. 14
GREEN’UPSOLUTION FOR CFloor standing or wall mounting, shock-rideal for vehicle fleets.identifying the empl
MEDIUM POWER BUSBAMS 63/100/160 AIn covered car parksthe ideal power distrPremium charging s
8 to 16 A charging in complete safetyof all electric vehicles with a mode 1
or mode 2 cable, regardless of howmuch charging power is required
by the vehicle
Optimum safetySurface treatment of metal contacts to
improve electrical conductivity
Vehicles detect the secure Green’upinfrastructure and select themaximum power that can besupplied via the socket, resultingin a shorter charging time.
DETECTION SYSTEMPATENTED BY LEGRAND
Heavy-duty socket, identifiedfor electric vehicles, also
suitable for any applicationConforms to IEC 60884-1
IK10 GREEN’UP ACCESS SOCKET
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 6 21/12/2017 09:58
77
pointhousing
cial sectorMODES 1 & 2
IP 55 - IK 1016 A - 3.7 kWsingle-phase
Charging time
RTIALLYMY ELECTRIC
PUBLIC CARHAVINGFRIENDS
6 hto
3 h(1)
Supplied with bracketAvailable withlockable flap
Line protected byRCBO.
Wiring diagramp. 14
Line protected byRCBO.
Wiring diagramp. 17
GREEN’UP PREMIUM IK 10 CHARGING STATION
(1) Average time for full charge in mode 3 according to manufacturer sources, varies according to the model
SOLUTION FOR COMPANY CAR PARKSFloor standing or wall mounting, shock-resistant, the Green’up Premium IK 10 charging station isideal for vehicle fleets. A card reader (optional) can be used to unlock the charging station byidentifying the employee and keeps a tally of the electricity used via a web page.
IP 55 - IK 103.7 kW single-phase
to 22 kW three-phase
Optional card readerUnlocks the charging
station and cankeep a tally of the
electricity used
Single-phase Three-phase
Charging time
IN THE CAR PARKAT MY PLACE OF WORKOR MY SHAREDOWNERSHIP PROPERTY,IT’S SIMPLICITY ITSELFTO IDENTIFY MYSELFAND CHARGE MYELECTRIC CAR.
“
MODES 1 & 2MODE 3
COMMUNICATING
1 hto
30min(1)
3 hto
1h30(1)
MANAGING CHARGING1 STANDARD (USING BLUETOOTH
WITH EV CHARGE)- Locking with Bluetooth- Programmable daily charging and
power management- Software update2 WITH COMMUNICATION KIT
(OPTIONAL)- Remote control of charging- Card-operated access control with
RFID reader- A bank of charging stations can be
managed via a web server- Consumption history
Secure accessCharging station
locked/unlocked viathe EV CHARGE app
MEDIUM POWER BUSBAR TRUNKINGMS 63/100/160 AIn covered car parks and garages, providesthe ideal power distribution for Green’upPremium charging stations.
For any electric vehicle modelShuttered T2S EV Plug socket
for mode 3 charging.
For any electric vehicle modelGreen’up Access heavy-duty
socket for charging in mode 2and for all applications
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 7 21/12/2017 09:58
8
Which charging pointin commercial areas with public access(shopping centres, public car parks, etc)
IN THE CAR PARK,MY CARD ALLOWSME TO USE THECHARGING STATION.I CAN CHARGE MYCAR WHILE DOINGMY SHOPPING
“
THREE-PHAS
INTEROPERABLEOCPP-COMPATIBIt can be controlledis easily integratedPayment for the ele
RFID encoder readeridentification system builtinto the charging stationwhich can activatesockets (optional)
Charging station cancommunicate on IP netwCompatible with existingoperating systems(Modbus, OCPP)
(1) Average time for full charge
Space available forinstalling modularprotection in the base
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 8 21/12/2017 09:58
99
point
arks, etc)
PARK,LOWSHETATION.
CHARGE MYDOINGG
THREE-PHASE GREEN’UP PREMIUM IK 10 CHARGING STATION
INTEROPERABLE CHARGING STATION FOR EASE OF MANAGEMENTOCPP-COMPATIBLE CHARGING STATIONIt can be controlled by a charging network operator: the Green’Up Premium charging stationis easily integrated in the car park manager’s billing system.Payment for the electricity used can be added to the cost of parking in the space.
IP 55 - IK 10adjustable from 11 to 22 kW
three-phase
Charging time
RFID encoder readeridentification system builtinto the charging stationwhich can activatesockets (optional)
CHARGE 2 VEHICLESAT THE SAME TIMEOne type 2S socketand one Green’upAccess socket oneach side of thecharging station
Charging station cancommunicate on IP networkCompatible with existingoperating systems(Modbus, OCPP)
(1) Average time for full charge in mode 3 according to manufacturer sources, varies according to the model
MODE 2MODE 3
COMMUNICATING
Space available forinstalling modularprotection in the base
MANAGING CHARGINGBECOMES 100% COMMUNICATING WITH THECOMMUNICATION KIT (OPTIONAL)
- Supervision and parameter setting in IP on web page
- Modbus and OCPP-compatible charging station(Open Charge Point Protocol)
- Managed with RFID reader
1 hto
30min(1)
Line protected byRCBO.
Wiring diagramp. 17
For any electricvehicle model
Shuttered T2S EV Plug socketfor mode 3 charging.
For any electricvehicle model
Green’up Access heavy-dutysocket for charging in mode
2 and for all applications
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 9 21/12/2017 09:58
10
CARD-OPERATED ACCESS CONTROLGreen’up Premium charging stationscan be integrated in the building’saccess control system. The chargingstation is locked and a personal ID cardis needed to dispense electricity.
Green’up Premium charging stations
Which solutions foridentifying, measuring,
controlling?ConsumptionmeasurementOne electricity meterper charging station
485
MANAGING WITH AN APPAccess control and control via theEV CHARGE app: monitoring chargingand option of locking the chargingstation via the app (making it unusableby third parties who are not using thecustomer account), monitoring anddisplay of consumption. Chargingprogrammed via the app for optimisedconsumption management.Software update via the app.
An IP converter,electricity meter andprotection devices can beintegrated in the base ofthe charging station.For charging stationswithout a base, tap-offboxes can be installednearby.
COMMUNICACCES
Green’up Premiumcharging station withcommunication kit
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 10 21/12/2017 09:58
1111
100% CONNECTEDMEASUREMENT AND CONTROL
OF CHARGING
On a PC: web pageRecord charging sessions by charging station(consumption, number of cards, etc) on electronic files
MEASUREMENT AND DISPLAYI.COMMUNICATING
+ CONTROL OF CHARGING
measuring,
On a PC: view thmeasure electricity consumption, optimise availableenergy (control charging by dividing energy between thedifferent charging stations).
Consumptionmeasurement
electricity metercharging station
Web serverUsed to display consumptionon any type of screenequipped with a browser:PC, smartphone, tabletcomputer, TV, etc
Supervision softwareFor displaying measurementon a PC
+
IP converter,ectricity meter andotection devices can beegrated in the base of
the charging station.or charging stationsthout a base, tap-offxes can be installed
nearby.
COMMUNICATION KIT WITH USERACCESS CONTROL (MIFARE RFID)
een’up Premiumrging station with
ommunication kit
GREE
N’U
PC
HA
RG
ING
SO
LUTI
ON
S
EXB17041_Bornes vehicules electriques.indd 11 21/12/2017 09:58
12
Green’up™ sockets and charging stationsfor electric vehicles and plug-in hybrids
IP IKCharging
modePower(kW)
Number ofcharging
points
Wallmounting
Freestanding
Options Average charging time(in hours) depending on
the vehicle and battery type
Communicationkit
RFID reader(Used with
communicationkit
Cat.No 0 590 56)
Vehicle battery capacity
15/16kW/h
22/24kW/h
30/32kW/h
SINGLE-PHASE SOCKETS - 230 V
Plastic 55 08 Mode 2 3,7 1 0 904 70(1)
0 904 72 - - - 5(2) 7(2) -
Metal 55 10
Mode 2 3,7
1 0 778 56 - - - 5(2) 7(2) -
Metalwith key 55 10 1 0 778 57 - - - 5(2) 7(2) -
SINGLE-PHASE CHARGING STATIONS - 230 V
Plastic 44 08 Mode 3
3,7 / 4,6 1 0 590 00 0 590 00+ 0 590 52 0 590 56 - 4 6 8
7,4 1 0 590 01 0 590 01+ 0 590 52 0 590 56 - 2,5 3,5 4,5
Plastic 44 08Modes2 and 3
3,7 / 4,6 1 0 590 30 0 590 30+ 0 590 52 0 590 56 - 4 6 8
7,4 1 0 590 35 0 590 35+ 0 590 52 0 590 56 - 2,5 3 4,5
Metal
55 10
Modes2 and 3
3,7 / 4,6
1 0 590 41+ 0 590 53
0 590 41+ 0 590 54 0 590 56 0 590 59
+ 0 590 56 4 6 8
2 0 590 42+ 0 590 53
0 590 42+ 0 590 54 0 590 56 0 590 59
+ 0 590 56 4 6 8
55 10 7,4
1 0 590 43+ 0 590 53
0 590 43+ 0 590 54 0 590 56 0 590 59
+ 0 590 56 2,5 3 4,5
2 0 590 44+ 0 590 53
0 590 44+ 0 590 54 0 590 56 0 590 59
+ 0 590 56 2,5 3 4,5
THREE-PHASE CHARGING STATIONS - 400 V
Plastic 44 08 Mode 3 22 1 0 590 02 0 590 02+ 0 590 52 0 590 56 - 1 1 2
Metal 55 10Modes2 and 3 22
1 0 590 48+ 0 590 53
0 590 48+ 0 590 54 0 590 56 0 590 59
+ 0 590 56 1 1 2
2 0 590 49+ 0 590 53
0 590 49+ 0 590 54 0 590 56 0 590 59
+ 0 590 56 1 1 2
1: Ready to install version, supplied with RCBO2: For vehicles with cable equipped with Legrand Green'up plug
Pack Cat.Nos Re
1 0 904 70 AllohybchaworPow1 doneThe k- 1pla230to I- 1con- 1CatTherecRecand
Complete solution:Mode 2 socket + RCBO
The Green'up sysactivating "maximcharging process
Green'up™ Accfor electric vehicle char
Installation principDimensions p. 14
EXB17041_Bornes vehicules electriques.indd 12 21/12/2017 09:58
13
Average charging timein hours) depending onvehicle and battery type
ehicle battery capacity
/16kW/h
22/24kW/h
30/32kW/h
(2) 7(2) -
(2) 7(2) -
(2) 7(2) -
4 6 8
,5 3,5 4,5
4 6 8
,5 3 4,5
4 6 8
4 6 8
,5 3 4,5
,5 3 4,5
1 1 2
1 1 2
1 1 2
Green'up™ Access sockets16 A - 230 V - 16 A EV - for electric vehicles
Pack Cat.Nos Ready to install kit - 16 A EV
1 0 904 70 Allows creating a safe infrastructure for electric andhybrid vehicle charging, using Mode 2 (or Mode 1)charging cables. Suitable for residential andworkplace usePower supply directly from the electrical panel:1 dedicated line 3 x 2.5 mm2 cable, protected withone RCBO (one line per socket)The kit contains:- 1 heavy duty German standard Green'up Accessplastic socket, with flap cover, IP 55 - IK 08 - 16 A -230 V - 16 A EV, 6 mm2 screw terminals, accordingto IEC 60884-1, NF C 61-314, VDE 620-1- 1 base for hanging up the vehicle charging cablecontrol box- 1 RCBO 20 A, C curve, 30 mA, Hpi typeCat.No 4 107 54The use of a surge protective device isrecommendedRecommended installation height: between 0.80and 1.20 m from the floor
Complete solution:Mode 2 socket + RCBO
+
The Green'up system is based on an innovative Legrand technology,activating "maximum power" mode and ensuring a secure and fastcharging process.
Green'up™ Access ready to install kitfor electric vehicle charging
0 904 70
Used for safely charging rechargeable electric and hybrid vehicleswhich take Mode 2 cord (compatible with Mode 1)Connected to the consumer panel via one 3 x 2.5 mm2 dedicated line(1 line per socket) protected by 30 mA - 20 A C curve, type A or HPiRCBO (or 30 mA type A or HPi RCCB + 20 A C curve circuit breaker)Recommended installation height: 1.30 m from the floorSuitable for residential and workplace use
Pack Cat.Nos Mode 1 and Mode 2 sockets - 16 A EV
Heavy-duty mechanisms with silvered contactsSingle-phase sockets - screw connection - 230 VSupplied with base Cat.No 0 904 78 for hanging upthe vehicle charging cable control boxFor charging 1 vehicleConform to IEC 60-884-1
IP 55 - IK 08 surface-mountingSuitable for installation in private housesPlastic socket with flap coverSupplied complete with surface mounting box fittedwith an ISO 20 cable glandDimensions (H x W x D): 98 x 98 x 70 mm(exc. cable gland)
1 0 904 72 German standard socket outlet
IP 55 - IK 10 flush-mounting - metal socketSuitable for installation in private houses, lock-upgarages, parking lots, etcSupplied complete with plate and supportMounting in 1-gang Batibox flush-mounting boxdepth 50 mmCan be surface mounted with box Cat.No 0 778 90Dimensions (H x W x D): 110 x 110 x 13.5 mm
1 0 778 56 German standard socket outlet
IP 55 - IK 10 flush-mounting - metal socket withlocked flap coverSuitable for installation in private houses, lock-upgarages, parking lots, etcSupplied complete with plate and supportMounting in 1-gang Batibox flush-mounting boxdepth 50 mmCan be surface mounted with box Cat.No 0 778 90Dimensions (H x W x D): 110 x 110 x 13.5 mmSupplied complete with a unique set of 2 keys inorder to restrict access to the socket
1 0 778 57 German standard socket outlet
0 904 72 0 778 56
Installation principle p. 14Dimensions p. 14
Installation principle p. 14Dimensions p. 14
EXB17041_Bornes vehicules electriques.indd 13 21/12/2017 09:58
14
16 A10 mA
Green'up Access2P+E socket
Dedicated line 3 x 2.5 mm2 minimum
(3 x 6 mm2 maximum)
L N
In electrical panel, dedicated RCBO Cat.No 4 110 9520 A, C curve - 30 mA - Type HPI
100
-12
0cm
Charging cable control boxsupplied with the electric vehicle
- Can be controlled by clock/switch type control units, etc.(to be ordered separately)- Use of a surge protective device is recommended
n Installation principle for an individual Mode 2 socket
n Use of bracket Cat.No 0 904 78
Green'up™ Access sockets
Charging stationscompliant with
ZE Ready(1) specifications
With power adjustmentfunction
For charging all electricsafety. Compliant with sCharging station powerBluetooth for configuratAvailable functions: chaupdates. Application adRemote wireless IP comEquipped with:- a 2P+E socket with Gr“maximum power” mod- a 3P+N+E (T2S) TypeConnected and protecteOff-peak control optionRemote ON/OFF contro
Green’up™ Premifor electric vehicle char
Technical characteristicsDimensions (p. 18
Pack Cat.Nos PlaMoIP 4Wawithgro
3,7/1 0 590 00 For
7,4Pow- 3,- 16
1 0 590 01 For
PlaMoIP 4Wawithgro
3,7/1 0 590 30 For
7,4Pow- 3,- 16
1 0 590 35 For
MeMoIP 5Mu- wawith- frewith
3,7/1 0 590 41 For1 0 590 42 For
0 590 30
98
117
98 70
n DimensionsCat.No 0 904 72
115 6
180 28
147.
5
92.5
Cat.No 0 904 78
110
110
Cat.No 0 778 56
26 21
110
110
Cat.No 0 778 57
26 48
EXB17041_Bornes vehicules electriques.indd 14 21/12/2017 09:58
15
Charging stationscompliant with
ZE Ready(1) specifications
With power adjustmentfunction
For charging all electric vehicles (equipped with single-phase and three-phase chargers) and plug-in hybrids in Mode 2 or Mode 3 in completesafety. Compliant with standards IEC 61851-1 and 61851-22.Charging station power can be adjusted with adapted protection devices and power supply circuits. Local wireless communication via embeddedBluetooth for configuration and control of charging station via smartphone or tablet using the IOS or Android compatible app.Available functions: changing station status, daily charging program, charging station activation/deactivation, power management, firmwareupdates. Application additional functions: weekly changing program, consumption monitoring with cloud storage for data, status notification.Remote wireless IP communication with communication kit Cat.No 0 590 56.Equipped with:- a 2P+E socket with Green'up Access safety shutter featuring the innovative Green'up system, a Legrand Group technology which activates“maximum power” mode, ensuring fast, safe charging for 2P+E plugs (Mode 2)(2)
- a 3P+N+E (T2S) Type 2 socket with blanking plates (single-phase or three-phase operation) with pilot wire (Mode 3).Connected and protected from the electrical panel via 1 protected dedicated line (2 dedicated lines for 2-vehicle charging station).Off-peak control option via contactor, clock and switch (volt-free contact input 12 V=).Remote ON/OFF control option (volt-free contact input 12 V=).
Green’up™ Premium charging stationsfor electric vehicle charging
Technical characteristics and wiring diagrams p. 17 and 18Dimensions (p. 18 and 19)
Pack Cat.Nos Plastic single-phase charging stations -Mode 3IP 44 - IK 08Wall mounting charging stations to be equippedwith pedestal Cat.No 0 590 52 for fixing to theground
3,7/4,6 kW - 16/20 A1 0 590 00 For charging 1 vehicle
7,4 kW - 32 APower adjustment option:- 3,7/4,6/5,7/7,4 kW- 16/20/25/32 A
1 0 590 01 For charging 1 vehicle
Plastic single-phase charging stations -Modes 2 and 3IP 44 - IK 08Wall mounting charging stations to be equippedwith pedestal Cat.No 0 590 52 for fixing to theground
3,7/4,6 kW - 16/20 A1 0 590 30 For charging 1 vehicle
7,4 kW - 32 APower adjustment option:- 3,7/4,6/5,7/7,4 kW- 16/20/25/32 A
1 0 590 35 For charging 1 vehicle
Metal single-phase charging stations -Modes 2 and 3IP 55 - IK 10Must be equipped with the following for:- wall mounting version: a mounting kit suppliedwith a metal front cover Cat.No 0 590 53- free standing version: a pedestal suppliedwith a metal front cover Cat.No 0 590 54
3,7/4,6 kW - 16/20 A1 0 590 41 For charging 1 vehicle1 0 590 42 For charging 2 vehicles simultaneously
Pack Cat.Nos Metal single-phase charging stations -Modes 2 and 3 (continued)7,4 kW - 32 APower adjustment option:- 3.7/4.6/5.7/7.4 kW- 16/20/25/32 A
1 0 590 43 For charging 1 vehicle1 0 590 44 For charging 2 vehicles simultaneously
Plastic three-phase charging station -Mode 3IP 44 - IK 08Wall mounting charging station to be equippedwith pedestal Cat.No 0 590 52 for fixing to theground
22 kW - 32 APower adjustment option:- 11/15/18/22 kW- 16/20/25/32 A
1 0 590 02 For charging 1 vehicle
Metal three-phase charging stations -Modes 2 and 3IP 55 - IK 10Must be equipped with the following for:- wall mounting version: a wall mounting kitsupplied with a metal front cover Cat.No 0 590 53- free standing version: a mounting pedestalsupplied with a metal front cover Cat.No 0 590 54
22 kW - 32 APower adjustment option:- 11/15/18/22 kW- 16/20/25/32 A
1 0 590 48 For charging 1 vehicle1 0 590 49 For charging 2 vehicles simultaneously
1: Charging stations compliant with ZE Ready 1.2 and EV Readyspecifications for construction regulations applicable to theseproducts. ZE Ready and EV Ready are registered trademarksof Renault.2: For vehicles with cable equipped with Legrand Green'up plug
0 590 42 + 0 590 54(p. 16)
0 590 30 + 0 590 52(p. 16)
0 590 30 0 590 42 + 0 590 53(p. 16)6
28
21
48
EXB17041_Bornes vehicules electriques.indd 15 21/12/2017 09:58
16
Dimensions (p. 18 and 19)
Pack Cat.Nos Equipment for mounting charging stationson the wall or fixing to the ground
For plastic charging stations1 0 590 52 Pedestal for fixing plastic charging stations
to the groundOption to integrate Plexo3 boxesCat.No 0 019 04/06/08(4 to 16 modules)for the protection devices
For metal charging stations1 0 590 53 Wall mounting kit with metal front cover1 0 590 54 Pedestal for fixing metal charging stations
to the groundSupplied with metal front coverOption to integrate protection devices on plates orrail chassis (dimensions equivalent to Atlantic box600 x 400 mm)
Green’up™ Premium charging stationsequipment for wall mounting or fixing to the ground
0 590 52
Identification via RFID badge0 590 59 + 0 590 56
Pack Cat.Nos Communication kit
For controlling functions embedded in the chargingstation and configuring the charging station remotelyfrom a smartphone or PC via IP (RJ 45) or Wi-FiAccess control: for association with centralisedreaders Cat.No 0 767 04 or standalone readersvia the Wiegand protocol
IP communication1 0 590 56 For connecting the charging station to the
installation’s IP network and ensuring itscompatibility with the following protocols:- OCPP 1.6 and 2.0- MODBUS RS 485 (one MODBUS address persingle charging station and two MODBUS addressesper double charging station)
RFID reader1 0 590 59 RFID system (identification via RFID badge,
integrated RFID encoder reader) available on metalcharging stations with communication kitCat.No 0 590 56Supplied with 1 badge to be activatedAdditional badges to be ordered separately ISOformat Mifare Classic technologyCat.No 0 767 11/12/13
13.56 MHz badges for badge readers
ISO format badgesDim. 50 x 80 mm
1 0 767 11 13.56 MHz Mifare contactless badge
1 0 767 13 13.56 MHz Mifare contactless badge4 KB extended memory
1 0 767 12 Mifare contactless dual technology badge+ chip 125 KHzRequired for operating an installation with carpark reader (customised)
Energy management multi-support webserversAllow remote configuration, test, control andvisualization, via a web browser on PCs,smartphones, web viewers, tablet computers, ofdata collected from: protection devices (DX3 add-onmodules with integrated measurement control unit,DPX3 and DMX3), EMDX3 electricity meters andmulti-function measuring units, CX3 energymanagement system and Green'up chargingstations for electric vehicles.Direct IP connection4 rail mountingPower supply: 9 to 28 V = with the help of asingle-phase switching mode power supplyCat.No 1 467 21 (see Legrand general catalog) tobe ordered separately
Numberof modules
1 4 149 47 For 10 Modbus adresses or 10 pulsemodules
4
1 4 149 48 For 32 Modbus adresses or 32 pulsemodules
4
Fixing on plate1 4 149 49 For 255 Modbus adresses or 255 pulse modules
Single-phase charging stations - Mode 3
Note: the wiring must
n Installation prin
Green’up™ Premifor electric vehicle char
Single-phase charging stations - Modes 2 and 3
16A10mA
ET
110/415V
4062
78
T2S3 x 2.
NL
For timed/off-pe3 x 1.5 mm2 vo
Safety signal 2 x 1.5 mm
Electrical panel
Option
For ON/OFF control2 x 1.5 mm2, v
Option
DX3
6kAC10
16A10mA
ET
110/415V
4062
78
T2S3 x 2
2P+E linestation powe3 x 2.5 mm
NL
For timed/off-pe3 x 1.5 mm2, v
* Except for charging stations
Safety signal
Electrical panel
Option
For ON/OFF co2 x 1.5 mm2, v
Option
Green’up™ Premium charging stationscommunication options
0 767 11
63A300mA
ET
110/415V
406278
DX3
6kAC10
63A300mA
Safety signal 2 x 1.5 mm
Electrical panel
Option For timed/off-peak3 x 1.5 mm2, volt-free
Option For ON/OFF control2 x 1.5 mm2, volt-free
T2S
2P+power supply: 3 x 2.5 mm
N
N
L
L1L2
L3
Three-phase charging
EXB17041_Bornes vehicules electriques.indd 16 21/12/2017 09:58
17
edded in the chargingharging station remotelyIP (RJ 45) or Wi-Fi
on with centralisedandalone readers
station to thensuring itsg protocols:
DBUS address perwo MODBUS addresses
a RFID badge,der) available on metalunication kit
activatedred separately ISOogy
badge readers
ctless badge
ctless badge
technology badge
n installation with car)
lti-support web
test, control andser on PCs,ablet computers, ofn devices (DX3 add-on
surement control unit,tricity meters ands, CX3 energyen'up charging
h the help of ae power supplyd general catalog) to
Numberof modules
0 pulse 4
2 pulse 4
255 pulse modules
Single-phase charging stations - Mode 3
Note: the wiring must be doubled up for a 2-vehicle charging station. The installation of a surge protective device is recommended.
n Installation principle
Green’up™ Premium charging stationsfor electric vehicle charging
Single-phase charging stations - Modes 2 and 3
Cat.No 0 590 00 0 590 01
Power setting (kW) 3,7 4,6 5,8 7,4
Charging station rating(A)
16 20 25 32
T2S line protection rating 20 A, C curve 25 A, C curve 32 A, C curve 40 A, C curve
RCD30 mA Type F
(e.g. Hpi)30 mA Type F
(e.g. Hpi)30 mA Type F
(e.g. Hpi)30 mA Type F
(e.g. Hpi)
T2S line protectionRCBO
4 110 95(6000/10 kA)
4 110 96(6000/10 kA)
4 110 97(6000/10 kA)
4 110 98(6000/10 kA)
T2S line csa(mm2 minimum)
2,5 4 6 10
Shunt trip / safety signal 4 062 76 4 062 76 4 062 76 4 062 76
Cat.No 0 590 30/41/42 0 590 35/43/44
Power setting (kW) 3,7 4,6 5,8 7,4
Charging station rating(A)
16 20 25 32
T2S line protection rating 20 A, C curve 25 A, C curve 32 A, C curve 40 A, C curve
RCD30 mA Type F
(e.g. Hpi)30 mA Type F
(e.g. Hpi)30 mA Type F
(e.g. Hpi)30 mA Type F
(e.g. Hpi)
T2S line protectionRCBO
4 110 95(6000/10 kA)
4 110 96(6000/10 kA)
4 110 97(6000/10 kA)
4 110 98(6000/10 kA)
T2S line csa(mm2 minimum)
2,5 4 6 10
Intensité protection ligne2P+T (A)
No 2P+E line 20 A, C curve 20 A, C curve 20 A, C curve
Disjoncteur protectionligne 2P+T
No 2P+E line4 077 43
(6000/10 kA)4 077 43
(6000/10 kA)4 077 43
(6000/10 kA)
Section ligne 2P+T(mm2 minimum)
No 2P+E line 2,5 2,5 2,5
Shunt trip / safety signal 4 062 76 4 062 76 4 062 76 4 062 76
16A10mA
ET
110/415V
4062
78
T2S line:3 x 2.5 mm2 min. / 4 mm2 / 6 mm2 / 10 mm2
NL
For timed/off-peak control, etc.3 x 1.5 mm2 volt-free 12 V contact
Safety signal 2 x 1.5 mm2
Electrical panel
T2S
Option
For ON/OFF control2 x 1.5 mm2, volt-free 12 V contact
Option
DX3
6kAC10
16A10mA
ET
110/415V
4062
78
T2S line:3 x 2.5 mm2 min. / 4 mm2 / 6 mm2 / 10 mm2
2P+E line and chargingstation power supply:3 x 2.5 mm2 min.*
NL
For timed/off-peak control, etc.3 x 1.5 mm2, volt-free 12 V contact
* Except for charging stations set at 16 A / 3.7 kW
Safety signal 2 x 1.5 mm2
Electrical panel
T2S
2P+E
T2S
2P+E
Option
For ON/OFF control,2 x 1.5 mm2, volt-free 12 V contact
Option
g stations
63A300mA
ET
110/415V
406278
DX3
6kAC10
63A300mA
T2S
2P+E
Safety signal 2 x 1.5 mm2
Electrical panel
Option For timed/off-peak control, etc.3 x 1.5 mm2, volt-free 12 V contact
Option For ON/OFF control2 x 1.5 mm2, volt-free 12 V contact
T2S line: 5 x 2.5 mm2 min. / 4 mm2 / 6 mm2 / 10 mm2
2P+E line and charging stationpower supply: 3 x 2.5 mm2 min.*
N
N
L
L1L2
L3
T2S
2P+E
Three-phase charging stations
Cat.No 0 590 02/48/49Power setting (kW) 11 15 18 22Charging station rating (A) 16 20 25 32T2S line protection rating 20 A, C curve 25 A, C curve 32 A, C curve 40 A, C curveRCD 30 mA Type B 30 mA Type B 30 mA Type B 30 mA Type BRCCB 4 118 46 4 118 46 4 118 46 4 118 46T2S line protectioncircuit breaker
4 079 29(6000/10 kA)
4 079 30(6000/10 kA)
4 079 31(6000/10 kA)
4 079 32(6000/10 kA)
T2S line csa (mm2 minimum) 2,5 4 6 102P+E line protection rating 20 A, C curve 20 A, C curve 20 A, C curve 20 A, C curve
2P+E line protectioncircuit breaker*
4 077 43(6000/10 kA)
4 077 43(6000/10 kA)
4 077 43(6000/10 kA)
4 077 43(6000/10 kA)
2P+E line csa (mm2 minimum) 2,5 2,5 2,5 2,5Shunt trip / safety signal 4 062 76 4 062 76 4 062 76 4 062 76
* Except 0 590 02
EXB17041_Bornes vehicules electriques.indd 17 21/12/2017 09:58
18
n Dimensions and mounting for plastic charging stations(mm)
Wall mounting charging stations
Cat.No 0 590 00/01/02/30/35
190
600 mini
900
min
i
300
min
i
Ø 6
Ø 6
Ø 13
200
250
205
Ø13
130
12m
ini
85
Charging stations compliant with ZE Ready 1.2 and EV Ready 1.4F specifications forconstruction regulations applicable to these products. ZE Ready and EV Ready areregistered trademarks of Renault.
140 250 45
365
173
123
250 45
1176
600 mini
n Dimensions and
Wall mounting charg
Cat.No 0 590 41/42/43
740
243
Free standing charging stations
Cat.No 0 590 00/01/02/30/35 + 0 590 52
Fixing to the ground
Green’up™ Premium charging stationsfor electric vehicle charging (continued)
Green’up™ Premifor electric vehicle ch
Manufacturer ModelStarting
from(year)
Batterypack
(KWH)
Mode 2Green'UpAccess
3,7 / 4,6KW
7 KW22 KW
AC
Estimatedchargingtime withLegrandchargingstation(1)
BMW I3 2013 22 X X XX
(11 KW)2 h
BMW I3 2016 33 X X XX
(11 KW)3 h
Bolloré BlueCar 2011 30 X X 8 hCitroën C-Zero 2010 16 Green'Up X 6 hCitroën E Méhari 2016 30 X X 8 h
Citroën Berlingo 2013 22 Green'Up X Optional 4 h
Hyundai Ioniq 2016 28 X X 7 hKIA Soul EV 2015 27 X X X 4 h
MercedesClasse BElectricDrive
2015 28 X X XX
(11 KW)3 h
Mitsubishi I-Miev 2010 16 X X 6 hNissan Leaf 2011 24 X X X 2014 4 hNissan Leaf 2015 30 X X X 6 hNissan e-NV200 2014 24 X X Optional 4 h
Opel e-Ampera 2017 60 X X X 9 h
Peugeot Ion 2010 16 X X 6 hPeugeot Partner 2013 22 Green'Up X Optional 4 hRenault ZOE 2017 41 Green'Up X X X 2h30Renault ZOE 2012 22 Green'Up X X X 1h30
RenaultKangooZE
2011 22 Green'Up X 7 h
RenaultKangooZE 2016 33 Green'Up X X 6 h
Smart Fortwo 2011 18 X X Optional Optional 4 hSmart Forfour 2014 18 X X Optional Optional 4 h
Tesla Model S 2012from 60to 100
X X X
X 11 KWand
22 KWoptional
6/10 h(depending
on theversion)
Tesla Model X 2016from 60to 100
X X X
X 11 KWand
22 KWoptional
6/10 h(depending
on theversion)
Volkswagen e-Golf 2015 24 X X X 4 hVolkswagen e-Up 2014 18 X X 6 h
1: Estimated time for full charging, depending on the capacity of the battery on the fastestcharging station
n Estimated charging time for the most sold vehicles inJanuary 2017
EXB17041_Bornes vehicules electriques.indd 18 21/12/2017 09:58
19
harging stations
250
205
Ø13
12m
ini
85
eady 1.4F specifications foready and EV Ready are
Free standing charging stations with front cover
Cat.No 0 590 41/42/43/44/48/49 + 0 590 54
1369
236 430
270
305
120
Ø 11,560
Fixing to the ground
595
1265
250
600 mini 600 mini
Ø 9
Ø 9
n Dimensions and mounting for metal charging stations
Wall mounting charging stations with front cover
Cat.No 0 590 41/42/43/44/48/49 + 0 590 53
430
740
243
Fixing to the ground
Green’up™ Premium charging stationsfor electric vehicle charging (continued)
EXB17041_Bornes vehicules electriques.indd 19 21/12/2017 09:58
EXB1
7041
©Le
gran
d-
Dece
mbe
r20
17
legrand.com
youtube.com/user/legrand
facebook.com/Legrand
twitter.com/Legrand
pinterest.com/legrandgroup
instagram.com/legrandnews
FOLLOW USALSO ON
Head officeand International Department87045 Limoges Cedex - FranceTel. : + 33 (0) 5 55 06 87 87Fax: + 33 (0) 5 55 06 74 55
EXB17041_Bornes vehicules electriques.indd 20 21/12/2017 09:58