eta floor mounted pkg unit

Upload: bhaveshbhoi

Post on 14-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    1/16

    ,,,nTA ENGINEERING PVT. LTD.www-eta-engg.com

    ffi1KK W&mww &ffiwcxxx&mffi$ffmamBs#effiffiffi& ffisaB&

    *E

    ffi.& w$& - *ffi Yffi

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    2/16

    ffiryK ff&mmr Mms&m**ffiffimmkmffiffiffi &3xa&*

    *{e*wy ffiu*tyw These heavy duty units are designed for use with Ducted AirSystem. They may also be used with an accessory plenum andgrille for free flow applications.e The units are equipped with quiet, large volume airmovement forward curved fans, with large outlet areas, tominimize air movement noise.C*mpresx*r

    * lmported hermetic scroll compressorRobust Engineered design meets heavy duty & criticalApplications.Higher efficiency, lesser electrical consumption, more cooling.Less prone to damages due to liquid not entering thecompressor.Less wear due to fewer moving parts.Side glass for checking of oil level.Silent operation.

    flmndsnser* Compact coil design using latest and most advanced highperformance tubes with lanced fins made on state of the artmanufacturing equipment.q Each coil pneumatlcally tested for leaks.a High efficiency multiple fans driven by lP44 motor

    ffivmpc*rmt*r6 lntegrated electrical panel on indoor unit with completemicroprocessor display for easy operation and maintenance.w Acoustlcally insulated fan section for low noise transmittance.&*$rfgwr*mt fllr*qi*tse lndependent refrigerant circuit for each compressor offersflexibility of operation at part load.o This also prevents refrigerant contamination problems

    associated in parallel operation of compressor with commonrefrigerant circuits.!r"lsulat*ons* The evaporator and suction line are insulated with closedSleeve rubber insulation.

    }fH:

    al ,.

    f,,

    ffi*

    ',t *

    Power Saving

    Clean Air

    Energy Efficiency

    Humidity Control

    Space Saving

    Progra m ma ble Operation

    &&

    &s&

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    3/16

    -z-. --==-= Ir-Z 6{ & , B ji E r ! E a :==-= EF6mmn f,M*ffiffiflm# ffimckmmryc$ UmEt ::y&ffimtmr flV$*r*sr*d *r: sl*de naEfi* Facilitate easy belt alignment / belt tensione lmprove efficiency, Lower maintenance cost

    lmported Blower& Low noise and high capacity.ffi Lower energy consumption

    noise less operation.

    Higher surface area increasesheat transfer rate.Faster cooling, lower energyconsumption, can workeffectively even at higherambient.

    Condenser Coil

    &*e*u*s*i** $*y I rtsul$xt*ci f* m s**ti*sre lnsulated with fiberglass, R.P tlssue &finished wlth perforated aluminium sheetsreduce noise drasticallyw Less noise in AHU room

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    4/16

    .:i'

    4 r Mounted packaged unit @

    Cabinet madeFrame wark & of AluminiumPowder eoated

    Dynamically balanced fansfor ncise free operations

    ae

    Extruded Anodised frame workCorrosion Proof, Easier tomaintain.Sleek looks, Longer Life.

    I nsulated powder coatedpa nels.Longer Life, Energy efficientLower energy consumption,Noise less operation

    Nylon Corner ProfileAvoids sharp edge, robustdesign.Sleek Looks, longer life.

    Ga

    c*

    6s

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    5/16

    ^.ilio*r i.vs*uffiE#ffi Pa*$

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    6/16

    mffi fitrrffi ffirmtrffi%sffir3. Hxtcras*we MemEt*r[m6(Easy Operation) operation statusdisplayed & continuous scrollingdisplay of following seven analogi n puts:

    Itr [- -x=ll r+ ttr ll llll trlrn .oor-

    templRerurnair)

    (0 &hcomp"1C!(6t

    (v) Yph Como-1 eurenlE-ffi] tb) Bp1 eomrJ cune*(r) Rpletiop.zcme4(v) Yill1 camF-2.Cu*ent(b) Eph camp-z Curenf

    ?. S*rwEc* k**(Malfunction Analysis Function)(16 Points Visual Alarm Annunciator)continuously monitoring ofcompressor to detect even smallestabnormality.Allfollowing faults after analysis &diagnosis are displayed on mainmicroprocessor controller.

    Phr*e!o"sr*lr.,', I ll1n.,, I I Blrase $equenco.r,1

    !fl-hals6cffientgYer k)ad Cuent

    ;1 qlrB{s nk"rEvapmwFait

    fiii. I illn * I I.. tr !tP- r-_*i---ittllrom: | [.r trfrR- llishEi i !o* gtrr'r I ll Sensor Eror

    Fault Diagnostics

    Fe*tunes *f fla'rta"aiklw* ilf,c/}S" FrHex-rd$y #permtf#m(Using Keyboard & Display) for extensive monitoring, analysis, diagnosis,program settings, selecting fan speed ....etc4" &x*try ffiest*rtAC unit will automatically restart in the same operating mode as beforeonce the power supply is restored (after temporary power failure).S. &ett& ffieege$* TEmerlncreases the compressor life.ffi. F*r.v*r $*w&mgAccurate dlgital temperature control action & electronic temperaturesensor saves the power.7. ffiqe,a*$ ffi*sr *f fl*mprassmrsln case of multiple compressors in one unit, automatic equal run ofcompressor is present.S" Mi6*t ffie$!m*p$*$ey

    qSAutoRestart

    Anti Recycle Timer

    Programmable Operation

    Countrywide Service

    Power Saving

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    7/16

    f;mEru Ht*wm L"$ ilM #

    1,) Easy to understand operation; advanced man machine interface(advanced MMI) through keyboard & 32 character's LCD display withbacklit.

    2) Group staggered delay timer to avoid same time starting of all units inone building after the power supply is restored.3) Diagnose check function.a. Malfunction analysis function should an abnormality occurs during

    system operation the alarm is displayed with cause, date & time.b. Alarm history the last 10 alarms can be accessed in the controller. Thisis useful for troubleshooting system abnormalities & helpful fordetermining error causes.

    4) Flexible control system.a. lndividual control intuitive UM model controller.b. Central control 64 units can be monitored by one central controller.c. Group control this function is used when operating multiple controllergroups at one time, using initiative utility manager (software) orcentral controller.Network Gateway.BMS compatibility.Service Tool.

    5) Yearly Schedule Controla. Day timer possible to set on / off time twice/a day.b. Set back timer possible to set temperatures for two time spans.c. Weekly timer possible to set on / off timings from Sunday to Saturday.d. Yearly timer holiday setting including public holidays for a completeyear can be programmed.

    b.

    Control System reliability.lndividual operation of each unit ensures that the failure of one doesnot affect the whole system.Maintenance efficiencies are raised through connection of a PCanywhere on data transmission line.

    Authorisation prevention of unauthorized & unwanted access isachieved through two level passwords8) Models of operation 3 difficult modes of operation are available :a. Scheduled Autob. Autoc. Test9) Real time clock.

    d.e.f.

    5)a.

    Authorisation

    Operation Friendly

    Delay Timer

    Yearly Schedule

    Flexible System

    RealTime Clock7)

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    8/16

    Finance Manager *pcraticnThe total electricity charges billed in apportionedaccording to the accumulated unit capacity.

    lnt*itive Utility Manager SoftwareHigh performance and optimum control system forvarious building applications.A. For Better Facility Management ability to collect

    data, share information & to control all thebuilding AC system.

    B. Finance Control of Modern Building calculatingelectricity charges. Total electricity charges billedfor multiple AC units connected. To the chargesmeter for air conditioning, is apportionedaccording. To the accumulated on the AC unitcapacity.

    C. EconomicAlternative.D. More functions Greater Flexibility.E. Service Tool (Software) extensive monitoring &

    analyzing functions operational status can bechecked & analised to detect even the smallestabnormality. By storing system operations in a PC,data can be checked even when offline.

    Fattern $ettingIt enables to recognize operatibn slaluE dp6rati6nl ' ',' ,mode,settempasacombinatioierll::", : =: i l. *

    : : .!: I .r :1 ::.! rri rr ii:. ,: .t ,r '.t: .l::. .t::t :i:. :r: + .+:l :-:re ill;' i-.t . .:. ::; .:+ .tl:: :j:. *. :-r.!: ni ::.;, 'i;: .::: i:i

    |- fl]flfill^.< l.#L [+H+]+--\ I\ I rnpui\ lo*a. [rl*-Jm IELECIRIC]TYCOMPANY

    ,/,_rI

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    9/16

    $rctru $t$vm LJ EVX e

    Wfl*effi kt*r:it*rlmg &, e*m?n*llir:g the*pee'*tlmm *f eae*"r umEt im detai8

    User frier':dly fi peratior:When monitoring & controlling the Operation ofWhole Building.1. Operational status can be color coded for easy

    recognitionE.g. ON / GREEN, OFF / RED, ERROR

    2. Operational status can be displayed to suit theUSC T.

    I aqrfl !l- j__,*/__,,_,, _,-----

    *per*tiam *f fias*n F$m*rWhen monitoring & controlling the operation ofeach floor.

    ffimsy $r:st*iEmtimrrA. Simple Connection by 2 core transmission line.B. Simple installation of software using only the CDsupplied.

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    10/16

    &rem$tHwm #M@ .G-frLwtr

    Tr*nd*Trends offer the most powerful tool for analyzingunits operation pattern and data values.

    ffi xt* e'rs*vm S*rc/em YsmSAlarms are accompanied with explanatory text manyalarms can be recorded for each unitA. Malfunction Diagnose FunctionB. Alarm History useful for trouble shooting.

    Scfuedas{e #mntn**Early schedule can be set for each unit.

    rni{ir 1ll!Imll Blinup ffii;rru ffi,:nttp !dclltl frita:p 117iirrulli

    li,S,il,J11ffdlllllS,fi{11tx{Eil#4,ttdllfr!,tll11[3f]1lr1104

    =l*p Iie,=t+f{ },'ltst!x htrIH 1=rl- l*;F3 frFtr Fs-lit lrci-=r lE-s. fifE6-ro. {.:ElEgrs. Fifii

    S@ Ia*:' Sre! Ti.i* =rlt* Fllt{ fti{ liti!li? la* f7 i?6-f?- Is* |;7'=E-I? lE* fi' ,=-lT;- f6- {i7 =E17 la* 17 g_:a-1,, 16- fi7 q:ar?- iE* :..i7- i:"

    J$1:FhI:fiiinl'l1ffixllh'l,1l]4 1-{ lli1

    1: fd ;J $j,il1 14 11 A}1.a ]151.&$lilHiiAlc!

    ';l rii,lllsl Filirr :Trrr:rFhtr 4-lrdilm iithlhr ?Ethff,il iiillhFhr:r i6illfrFlas ]ff

    [ritltalti ll:] ti!{.i Euiidrqlhx Lnrilil l[rilmriiur$i,lrerlad tueRi ti:ii,l iuldrrqi,ripliri:i[* lllll*ilrldirtrlrirr;r:r[rr lfi{},trrtrj'.iiirtriPr i4 liilltrild;qft a:t*d il'r*l li;lt iurirjrq

    tlrarT l{*surifEYilONf,}&YTt {g$*Y*J=D*&!*iaY?n3*s$Fff :r*;$sY*af{J&iraYHa{daa:- fi?ii-E 1ls.;[5rr. fi1Fi-6

    *. |E-IE5ts. fl$6te $i?iTu--6{E-=

    F-5t{* f-s|{at t{lilt6* F-l.* Fi-l** l*-ls- F*I** ,r-ilE* lr-F* S-tEini"i75,!ifiurT

    lffelffil::.r:

    ffifk*r, ffimm${mrlmg & #p*rmt$mrs *att*fua.t$*r fmr*'tr* *$ aash*$* fuax$fiSimg.

    I]iJff.l4 113-1 p[i11i6,fl4 1: 1! pi,l]]C5;EI II50Al',111f;5,0i 11 3: AM1r{d{r 1t i0 ar,I11i:.,l,lJl 1f:5UAi,rJ1lf38,1 1[:!0 Xlvl11fi:[J4 1f;:lt] Al'il11i:fll ?:58Allll,!lJl]l S;18 lln11,::,1-"rI !:1"t A[,1l l,.:1I11 !:fi F[,1l1{!il4 -i.3I Pk1

    h0rtQtt0ql-:frlr';lnrl,r,lr!rfnir:rI

    Hrgh,lrghii$h

    lil8XiilhLs{

    hled umH,shl-lishHighili$h15h

    ii,lei r! rntriEdirinl

    1;i i ltrlii i *trini Fldt?ni Flroriiid Fiorrid fimrlrd finrrJrii Fiocriii i rlri:lh Fl*irlilh f[]!r'l:iI Flnil

    F-ry_gr_s_ryryrytffi_ry**ry*e^*""*" -_ . *,ffi. Lil,SG".p: r":-:,8..,': ._,@ ltIi;BB:.j!{:r+# &*,iS,

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    11/16

    -A A Edq"GA ffinawings5.5TR G& mffi&kv!ruG$

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    12/16

    ffi& ffirmw$ffiffis#.sYffi ffi& ffiffi&w*ffiffis

    FrqLJaFirq*]

    BHtrlt-loFHfr

    FHFizo

    Fi

    td{q eqa? a(qsFi

    Ftr]F{

    00'1ns

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    13/16

    ffi& ffirmwimffiss3"Yffi ffi& ffiffietuvrruffi$

    tsrrJlra?trr

    EfElR'Frts\)

    F!.'.iREIN.DHEr)E)

    c5-lHi!i{RgF E -E iSli. tt** E:. rH,ooi.eJS.-'bieQe5 i' Qss- HsI' 3 -H c i! ;?:l EEAI B !il EsuEi Siri !61: Er:a tsscad EilY a.

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    14/16

    ffi& ffirmw&nffi$a?Yffi ffi& ffiffi&W$ruffiffi

    tsE{FrIaan['.r!'jv

    rr1Ek

    Hi>$;l ,loi!s! a-,S 466 NqSP3 ; t= bFFn ri d ^r3,:;EX* iF' [iE HtiC {YCaE d$i ei- {")NolHi&L[ tr .59 saoe5 l' 3sr. lsS- i 'E :i ;!il Sit\ ( ril Sqrti Eii= rEl= {s=a iscHd itv3 a[Ed :id

    !.titrfA\anE.rr\taEl

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    15/16

    ffi,& ffinmw$r'effi$ffieYre ffi& mffi&%dW*EWffi$

    FUU&6I

    =rEr +H! EOi,!o6- ouusEg^l=? ' eE;iro - r-F>Z5zx@- +itrEs-i9d-a-U!11^a-=26YS=-Aerou66iUI r --!l= , 6 s?l; a 52 *=i3l - t 3t F'--16 0 -;+ Jrs14 ExgE: ar'rl' "s Q=EF? ==i2| - zLzv)I

    3to4&

    Fz

    ffi

    EE

    E=$&L&AEEffs

  • 7/30/2019 ETA Floor Mounted Pkg Unit

    16/16

    @TA ENGINEERING PVT. LTD.www.eta-engg.com

    KffiWb& WKwww ffiwcsffie&mffi$Pmmkmgwffi ffim&&m

    *i%ffi

    .%.flp '$'$t - *ffi '$-$t