esp 214.04b hi-velocity explained, he online version
TRANSCRIPT
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
1/12
www.hivelocity.com
What are Hi-Velocity SystemsTM? Hi-Velocity Applications Science of Hi-Velocity SystemsTM
How Hi-Velocity Cooling Works Printed Circuit Board Controls and Operation Hi-Velocity Tools
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
2/12
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
3/12
TheHi-VelocitySystemisahighpressureforcedair
deliverysystemthatcanbedesignedtoprovideheating,
cooling, ltration, ventilation, and humidication.The
Hi-VelocitySystemhasbeenpre-engineeredandworks
ontheprincipleofpressureratherthanairvelocity.
TheHi-VelocitySystemdoesnotmakeorbreakanyexisting laws;it just uses those lawsdifferentlythana
conventionallowvelocitysystem.Itisquitedifferentfrom
aconventionalfurnace,themaindifferencebeingthatthe
supplyductworkisallsmalldiameterorminiduct.
Because the plenum duct is pressurized, dust
build-up within the duct work is eliminated. With
continuousaircirculationfromtheconstantfan,airborne
dustandotherallergenscanbeeasilylteredoutofthe
air.Withapressurizedsmalldiameterductwecondition
theairdifferently thanconventionalforcedairsystems.
With the use of a high pressure area to lowpressure
area,wecontinuously mix the roomair, creatingeven
temperaturesfromoortoceiling.
Our Coolingmodules are highly efcient and very
effectiveatremovingmoisturefromtheair.Notonlydo
wecooltheair,weusealowerairvelocitywhichallows
theHi-VelocitySystemtoremovemoremoisturefromthe
passingairmolecules.
TheHi-VelocitySystemachievesa superior Indoor
AirQuality(IAQ)withan innovativefancoilandcooling
moduledesign.Thistechnologyhelpscreateahealthier
andmore enjoyable indoor living environment for the
end-user.
The key to Hi-Velocity SystemsTM -How we Provide these Benets:
Hi-Efficiencyprogrammableenergysmartmotors
Ourfancoilunitsaremodular,conveniently located,
andcanbeinstalledinavarietyoforientations
Roundplenumductforeasyinstallation
Our2&HEflexductdeliversairunderagreater
pressurethanaconventionalsystem.Thisincrease
inpressureforcesthemixingoftheairintheroom,
eliminatingstratication
Our flex duct is insulated to prevent heat
loss/gainandhasasoundabsorbinginnercoreto
delivertheairwhisperquiet
Smaller duct also allows for greater flexibility in
installationswhilesavingspace
Vents are adjustable andcan be installed in the
floor,ceilingorwallinavarietyofstylestoblendin
withtheirsurroundings.
IAQHi-Velocity SystemsTM Improve
Indoor Air Quality
In the last several years, scientic evidence ha
indicated that the air within homesand otherbuilding
can containmorepollutants than the outdoor air.Wit
peoplespendingapproximately90percentoftheirtim
indoors,thehealthrisksmaybegreatertoexposureo
airpollutionindoorsthanoutdoors.Peoplewhomayb
exposedtoindoorairpollutantsforthelongestperiodso
timeareoftenthosemostsusceptibletotheeffects.Such
groupsincludetheyoung,elderly,chronicallyill,orpeople
sufferingfromrespiratoryorcardiovasculardisease.
Hi-VelocitySystemsTMcanprovidetheanswerstoa
your IndoorAirQuality needs. TheHi-Velocity Systemutilizes a constant fan for air delivery which can hel
eliminate conditionsthat promotemoldandmildew.B
controllingyourenvironmentwithcontinuousaircirculatio
and moisture control, conditions that will allow thes
harmfulsporestheopportunitytotakeholdarereduced
Forpeopledealingwithrespiratoryorcardiovascula
disease, the Hi-Velocity System can easily beused i
conjunction with add on ltration equipment. With th
versatilityofourunits,charcoal,electronic,electrostatic
andhepaltersareeasilyaddedontoprovideyouwit
acleanerandhealthierlivingenvironment.Whendealin
withmoisture,humidiers,de-humidiers,andatomizer
canallbeusedinconjunctionwiththeHi-VelocitySystemFreshaircanbesupplieddirectly,orindirectlythroughthe
useofaheatexchanger.
How the Hi-Velocity System can -
Improve your Indoor Air Quality:
Eventemperaturethroughoutthestructure
Filtration
Freshairmake-up
Humidication
Dehumidication
Reduceconditionsthatpromotemoldandmildew
What are Hi-Velocity SystemsTM?
01TM
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
4/12
Commercial Multi-Family New Construction Retrofts
Applications for Hi-Velocity SystemsTM
The Hi-Velocity System can be utilized for most
projects,butsome typical installationsarecommercial,
multi-family, new housing construction and the retrot
market.Withtheversatility,quickinstallationandsuperior
IndoorAirQualityprovided fromour systems, theyare
nowapopularchoicewithhomebuilders,installersand
theenduser.
Commercial
In commercial applications, exposed plenum with
drilled outlets is the ideal choice. Drilled outlets are
commonlyusedtosupplyalargeareawithheatingand
cooling.Theycanalsocreateapressurizedaircurtainfor
baydoorsorlargeopeningstotheoutsideenvironment.
Multi-Family
Manybuilding contractorsareutilizingourspecially
designed HV-52 units for multi-family structures. The
Space Saver model is the same as other Hi-Velocity
SystemsTMwiththeexceptionofthesupplyairtake-off.It
wasdesignedforclosertake-offpoints.Thismodelcomes
with 5 available supply outlet locations, four 6 supply
outletsandone8outlet.Withtheadaptabilityofthisunit,
itwill t inalmostanycloset,crawlspace, oranywhere
elsewherespaceisanissue.
New Construction
When you want to improve your living standards,
theHi-VelocitySystemistherightchoiceforcoolingand
heating.Whywastespaceframingout largeduct runs
reducingtheyourlivableareawhensmallroundplenum
and exibleductscanberun throughoors,wallsandceilings.Notonlywillyou improveyourlivingstandards
with the Hi-Velocity SystemsTM, they save you space
allowingyoutoenjoyyourhomethatmuchmore.
Retrofit
In older homesupgrading the heating and cooling
system, there is no better choice than the Hi-Velocity
System.Thesmallductsareeasytopullthroughwalls,
oorsandceilingswithverylittlechangestotheexisting
structure.
Features of the Hi-Velocity System
UnitPre-assembledfromthemanufacturer
MassowVariableFrequencyDrives
-6independentspeeds
AutomaticVoltage&FrequencyRecognition.
110/230volts,50/60cycles
Flexibilityinunitlocation;canbemountedVertical,
HorizontalorintheCounterFlowposition
CoolingandHeatingmodulescaneasilybeadded
toanyunitatthetimeofpurchase,orlaterasan
upgrade
LargeselectionofHeatingandCoolingmodules:
WaterCoolingmodules
RefrigerantCoolingModules
WaterHeatingCoils
ElectricStripHeatingCoils
HeatPumpcompatible
8and10RoundPlenummakesinstallationeasier
andincreasesusablespace
Ourpre-assembledexible2&HEductisavailable
in10and15standardlengths
Flexible2&HEductextensionkitsforlongerruns
Ventscanbeadjustedfornetuning
Varietyofventplatestomatchanydecor
SingleSideAccessforeasymaintenance
AdjustableTXvalve
Compatiblewithmostcommonrefrigerants
Easilyadaptabletothirdpartyequipment
02
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
5/12
CalvinDoddMacCracken(1920-1999),anengineer
andinventorfromNewJersey,iscreditedwithbuilding
the first highvelocitystyle airhandler, usingsmall
insulatedductsto deliver heatedair at considerable
pressureandhighvelocity.Thissystemquicklygained
inpopularity,andaspublicinterestgrew,acompany
cal led Space Conditioning Inc. incorporated theMacCracken Forced-Air House Heating Apparatus
(Patent 2,488,548) into theirproduct lines. Thisunit
later became known as the Jet-Heet System. The
primarymarketforthesystemwasretrofitcoolinginto
homesthathadlittleroomforductworkorinwhich
architecturalchangeswereundesirable.MacCrackens
airhandlerwasbasedontwoscientificprinciples:
Bernoullis Principle: (DanielBernoulli 1700-1782)Wherethereisdecreasedflow,youwillfindincreased
pressure.Wherethereisincreasedflow,youwillfind
decreasedpressure.
Venturi Effect: (GiovanniBattistaVenturi1746-1822)The increase in the velocity of a fluid stream as it
passesthroughaconstrictioninachannel.Calculated
by the Continuity Equation Q = VA where Q is the
volumetricflowrate,AistheareaofflowandVisthe
fluidvelocity.BecauseQdoesnotchange,asAgets
smallerthenVmustincrease.
Bernoullis Principle
Bernoullis Principle plays an important part in the
operationoftheHi-VelocitySystem.Toillustratehowthis
works,letslookatthedynamicsofashowerhead.With
the showerhead in place, you create pressure in thepipingandmoveasmallamountofwaterquicklythrough
the showerhead holes, with the water being equally
distributedtoeachhole.Ifyouremovetheshowerhead,
youremovethepressure,andbeginmovingalotofwater
slowlyandinonebigstream.Ittakesthesameamountof
energytomoveasmallamountofwaterquickly,asitdoes
tomovealargeamountofwaterslowly.Theamountof
energyyouhaveavailabledependsonyourwaterpressure.
Thesmallholesintheshowerheadcreateapressurepoint
inyourwaterline,makingthewatermovingthroughthat
piperetainahighpressureandlowvelocity.Oncethewater
leavestheshowerhead,itisnolongerunderpressure,so
thevelocityincreases.
Thisisverysimilartohowtheairowworkswiththe
Hi-VelocitySystem.Ourfancoilpressurizestheductwork
justlikethewaterpipeofyourshower.Ourventoutletsact
liketheholesintheshowerheadtoconvertthepressure
tovelocity,anddelivertheconditionedairtoyourhome.
Sinceairowandwaterowfollowthesameprinciples,
youwillgetequalairowfromalloftheHi-VelocitySystem
ventsinyourhome.Thisholdstruefromtherstbranch
ducttothelastone,andismodiedonlyduetofriction
fromlongerlengthsofbranchducts.
Thesystemmaintainsahighpressurewithintheduct
which results in a low air ow within the duct work.
Whenreleasedfromtheduct,thispressureisconverted
tovelocityattheoutlet,goingfromahighpressurearea
toalowpressurearea(theopenroom).Thehighervelocity
oftheairleavingtheductforcestheairwithintheroom
tomixbasedontheVenturiEffect.
Venturi Effect
Whenthehigher-pressureairleavestheventofthe
Hi-VelocitySystem,itexpandsrapidlyandcausesalower
airpressurearoundthevent.Thiscausestheroomairto
bedrawntowardtheairstreamthatisleavingthevent.By
applyingtheVenturiEffect,theHi-VelocitySystemcauses
thethoroughandcontinualmixingofroomair,eliminating
the possibilityof hot and coldspotsfromdeveloping in
thehome.Withotherairsystemsthatoperatewithless
pressure, this effect doesnot occurto any appreciable
amount.WiththeHi-VelocitySystem,whethertheventsarelocated in theoor, ceiling orwall, complete and
consistentmixingoftheairwillalwaysoccur.Toallowfor
customlevelsofcomfort,everyventhasabuilt-indamper,
makingiteasytocontrolindividualroomtemperatures.
Vent Outlet Utilizing the Venturi Effect
The Science and History of Hi-Velocity Systems
03
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
6/12
Witha conventional lowvelocity forced air-cooling
system,therulethateveryoneknowsisavolumeof400
CubicFeetofairperMinute(CFM)foreachton.With
400CFMatalowstaticpressure,andalargefacearea
/thindepthcoil,theairiscooledandasmallamountof
humidityisremoved.WiththeHi-VelocitySystem,weusealowerCFMbuthigherstaticpressuretoaccomplishthe
sameamountofcooling, removingmore humidity from
theairintheprocess.
400CFMisadesignruleforconventionalheating
systemsandwillputanoptimumloadontheindoorcoil.
This allows the coil toproperlyevaporate refrigerant
andperformheattransfer.Sinceconventionalheating
systems use a lower pressure than Hi-Velocity
SystemsTM,ahigherairowisneededtoprovideenough
massofairtoperformtheheattransfer.Inversely,the
more pressure that the air isunder, the lessCFM is
needed.How thisworks ison the microscopic level;the amount ofair molecules present through the coil
determineshowmuchheattransferisdone.Undera
higherpressuretherearemoreairmoleculespresentper
cubicfoot.TheHi-VelocitySystemrequireslessCFMof
airtopassthroughtheevaporator,whilestillproviding
thesamecoilload.
Withasmuchcoilload(ifnotmore)passingthrough
theevaporator,equalorsuperiorcoolingwillresult.An
additionalbenettomovingmoreairmoleculesthrough
thecoilatalowerrateisthelatentcooling.Sincethe
air passing through the coil is in contact with the coil
surfaceareaforalongerperiodoftime,thetemperature
isdroppedlowerthanwithconventionalsystems,thus
reducingtheairsabilitytoholdmoisture.Ourcoilshave
aunique design; theyare highly efcientand typically
thicker than coils in conventional cooling systems.
Withourstyleofcoolingcoilwewillremoveuptothirty
percentmoremoisturefromtheair.Thishasthebenet
ofallowinga greater thermal comfort level, even ata
highertemperature.
Airvelocitycanbeeitherahelporahindranceto
thermal comfort levels. While a small amount of air
movement isdesirable toincreasetheskinevaporationrate, ithasto beauniformmovementover the entire
body in order to provide benets to thermal comfort
levels.Anylargeamountsofdirectairvelocityovera
part of the humanbodywill causean uneven rate of
evaporationandheattransfer.Thisiswhytheventsfor
theHi-VelocitySystemareusuallylocatedinlowtrafc
areassuchascornersofaroom,ortothesidesofdoors
andwindows.Bylocatingtheventsintheseareas,the
amountofdirectairmovementthathumanswillcomein
contactwithwillbeminimized,sincetheventshaveonly
aneight-inchconeofdirectinuence.
Airtemperature,humidity,anddirectairvelocityare
the factors that will cause the most change to thermal
comfortlevels.Mostpeoplebelievethatcoldairisthekey
factorforagoodairconditioningsystem.Consideringthat
thehumanbodyhasanaturalcoolingsystembuiltin,the
keytocreatingacomfortableenvironmentforthehumanbodyistocreatetherightcombinationofenvironmental
factors.
Parameters that describe thermal comfort.
Airtemperature
Wet-bulbtemperature
Dewpointtemperature
Watervaporpressure
Totalatmosphericpressure
Relativehumidity
Humidityratio
Airvelocity
Meanradianttemperature
Airtemperatureis onlythestartingpoint increating
a comfortable environment. By reducing the inside air
temperatureto 70Fa personmaybecomfortable toa
certaindegree.However,inahighhumiditylocation,youcouldstillhavetheclammyfeelingduetoallthemoisture
intheair.Thebodywillnaturallyevaporatethismoisture,
whichcouldleadtoacolduncomfortablefeeling.When
thehumidityleveliscontrolledataproperlevelaperson
canbecomfortableatahigherindoortemperature.With
noevaporationontheskinsurfacebeingexperienced,no
heattransferwillbetakingplace,allowingtheindividualto
enjoyaconstanttemperatureontheskinsurface.
Airvelocitywithinaroomcanalsohaveabigeffect
on comfort. When not enough airow is introduced,
straticationandroomseparationmayoccur.Stratication
isthelayeringofhotandcoldair;hotairwillalwaysrise
andcanresultinabigtemperaturedifferencefromoor
toceiling.In conventionalsystemswhichusethe throw
anddiffusionmethod,separationcanoccurfromoneside
ofthe roomtotheother,withtheair closer tothevent
usually being colder. Both stratication and separation
happenwhenthereisnomeansofcirculatingtheroomair.
TheHi-VelocitySystemprovidesconstantair circulation
throughtheVenturiaffect,neverallowingstraticationor
roomseparationtooccur.
How Hi-Velocity Cooling Works
04
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
7/12
TheHi-VelocityCircuitboardmakeswiringoftheun
aquickandsimpletask.Withclearlylabeledconnections
itiseasytowireinthethermostat,condenserandanti-
icecontrol.WithourAuxiliaryRelayandDry Contac
connections,anyapplicationthatrequires24volt,110
volt,230volt,ordrycontacts(boilers,hotwaterheaters,
heatpumps,humidiers)canbeautomaticallystarted
when there is a call for heat. When the Hi-Velocity
Systemisusedtosupplementradiantoorheating,the
HotWaterZoneValveterminalsautomaticallyactivate
thezonevalves.
Timer Chip
Theprintedcircuitboardwithinthefancoilcontainsa
timercircuit. On some systems(when applicable), this
timer will cycle the pump on potable water systems
to ush the water through the system during summe
monthsandpreventanystagnation.Thetimercircuitis
equippedwitharedashinglightinthecenterofthecircui
board.Itisnormalfortheredlighttobeashingasitis
showingusthatpowerisbeingsuppliedtotheunit.
EPC Circuit Board
05
Circuit Board Features:Automatic voltage and frequency recognition circuitry,
115 or 230 volt, 50 or 60 cycle, our electronics will
adjusttotheinputautomatically.
protectedwithanintegralsurgeandfusesystem.
Built-in 2 stage heating/cooling terminals
Dehumidiersequenceprogram
A constant fan operation that can now be controlled
from the thermostat
potable water timer circuit
20 va transformer is built into the circuit board for
auxiliaryuses
Auxiliary heating relay is included for dry contact
applications.
Thermostat terminals follow industry standards for
easeofinstallation.
Terminalsforyour;
Heatingzonevalve,
Coolingcondensingunit,
Anti-icecontrol,
B/O heat pump
Neutral C terminal
aresuppliedtosimplifytheeldcontrolwiring.
Dynamic pump duty cyclechip provided toprevent
water stagnation in potable water systems and to
providepumprotorprotection.
Auxiliary Relay
Connections
Line Voltage
Control InterfaceLow Voltage
Control Interface
Thermostat
Connections
20 VA TransformerTimer On/O SwitchTimer Chip
Hot Water
Zone Valve
Condensing
Unit
Anti-Ice
ControlEPC Circuit
Board
The Circulator Timer Chip on our circuit board wil
energize thepump for5 minutesevery24hours.This
timingcyclestartswhenpower is turnedon tothe fan
coilunit,andwillbeengagedatthesametimeeveryday
Ifyouwishtohavethetimercycleoperateataspecic
timeofday,simplyturnoffpowertothefancoilunitfor
threesecondsatthattime,andthenturnthepowerback
on.Ifyoudonotneedtousethetimercircuit,movethe
jumperheaderfromtheONpinstotheOFFpinsandit
willbedisabled
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
8/12
Control Board Features
Hi-Velocity-HE Systems areeld programmable from
1.5to5tonsofcooling
Each programmed tonnage will have up to 5
adjustments
FastandSimpleOn-sitenetuning Themotorandcontrollerareseparateunitsandrequire
norecalibration
Heating Mode
Boilers,hotwatertanks,heatpumps,andgeothermal
systemscanallbeusedasheatsourcesfortheHi-Velocity
System.Wealsomanufactureaslide-inelectricstripcoil
thatisavailableforusewiththesystem,easilyinstalled
withoutanyexternalmountingorductworkrequired.
Whentheunitisinheatingmode,theAuxiliaryrelayisalso engaged.Themost common use for this relay
is to start a circulator pump for heating; however, the
auxiliary relaycanbe used for110volt,24 volt,ordry
contact operationdependinguponyourneeds.Also in
heatingmode,24voltpowerissuppliedtotheZoneValve
Terminalsincaseyouhaveanormallyclosedzonevalve
withyourfancoil.Withmorepeopleusingradiantoor
heating,ourcircuitboardreducestheuseofthirdparty
relays resulting in a faster installation and helping the
installertodiagnoseanyproblemsinthefuture.
Thecirculatortimerchip onour circuit boardwil
energizethepumpfor5minutesevery24hours.This
timingcyclestartswhenpoweristurnedontothefan
coilunit,andwillbeengagedatthesametimeeveryday.
Ifyouwishtohavethetimercycleoperateataspecictimeofday,simplyturnoffpowertothefancoilunitfo
threesecondsat that timeofday,thenturnthepowe
backon.Ifyoudonotneedtousethetimercircuit,the
jumperheadercanbechangedfromtheONpositionto
theOFFpositionanditwillbedisabled.
Cooling ModeCondensing units, chillers, heat pumps and
geothermalsystemscanallbeusedascoolingsources
fortheHi-VelocitySystem.
Whenthefancoilgoesintocoolingmode,themoto
switchestothedesiredcoolingspeed,eitherHi-Cooling
orLo-Cooling.Properairowisveryimportantwhenthe
unitiscooling,andourprintedcircuitboardensuresthe
motorspeedisalwayscorrect.Incoolingmode,24vol
powerissuppliedtotheCondenserUnitterminalswhich
starts the outdoor condenser. This power rst passes
throughtheFreezeStatterminals,ensuringtheunitisin
areadystate.
EPC Control Board
06
Low VoltageInterface
Line VoltageInterface
MotorInterface
Dip SwitchProgrammable Settings
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
9/12
System Operation
OntheHi-VelocitySystemHEmodel,thefancoil
unithassixindependentmotorspeeds;
Hi-Cooling
Lo-Cooling
Dehumidication
Hi-Heating
Lo-Heating
ConstantFan
Cooling Automatically Controlled
WhentheHi-VelocitySystemswitchestoCooling
mode,themotorisautomaticallysettohighspeed,to
ensureproperairowacrossthecoil.Thiswillresultin
thebestpossiblecoolingandmoistureremovalfromthesystem.
Potable Water Timers
InrecognitionofconcernsexpressedbyPlumbing
Inspection Departments, Engineers, Home Builders,
Home Owners, and Installing Contractors, the Hi-
VelocitySystemoffersatimerprocessorwhichcanbe
enabledonourprintedcircuitboard.Thisallowswater
from an approved dual purpose water heater to be
circulatedforaveminuteperiodevery24hours.
The timer processor overcomes the possible
concern ofwatercontaminationwithin the system. It
alsohastheaddedbenetofdutycyclingthecirculator
everyday,eliminatingalockedrotorwhichissometimes
experiencedduring long shutdownperiodsonwater
lubricatedcirculators.Thetimeoperationcanbesetat
anytimebydisconnectingthe110voltpowersourceto
thefancoil,andthenre-connecting.Eachtimepower
isappliedtotheunit,thetimeractivatestheveminute
override,conrmingoperation.
Evenonclosedloopboilersystems,thetimerprocessorcan be benecial. In a closed loop system, water
contamination is not a concern, but duty cycling the
zoning controls will increase the life expectancy of
thosecontrols. Inadditionto helpingto reducelocked
rotorsoncirculators,theprocessorwillalsodutycycle
hydronic zone valves.Approximately80%ofall zone
valvefailurecanbedirectlyrelatedtostuckportsdueto
offseasonbuildup.Thetimerprocessorwasdeveloped
fromconsumer inputandcangreatly increasesystem
reliability.
Constant Fan Control
TheConstantFanControlisenabledwhenthereis
nodemandforheatingorcoolingfromthethermostat.
Itisoptionalandcanbeturnedoffifnotdesired.
Thereisgreatbenetwithusingthisconstantfan
control.Itprovidesltrationcontinually,andcanalso
helpreduceyourenergycostsforyourhomebygently
stirringtheairwithinyourhomeconstantly.Thiscan
eliminate hot and cold spots(stratiedair) that can
commonlyoccurwithconventionalsystems,andcan
save you energy as it prevents the majority of the
heataccumulatingattheceiling,creatingamoreeven
temperaturethroughoutthehome.
System Efciency/Performance
Theconstantfanreducestheamountofstratication
withinthehome,andevenwiththeheating/coolingoff
itcangiveyoumuchmoreeventemperaturesbetween
oors. This feature basically gives you a constant
stirring effect of the air throughout the house. The
amountofpoweractuallyusedwiththisconstantfan
operationisaboutthesameasa100wlightbulb.
WiththeHi-VelocitySystemyouwanttomaintain
your housewithin a 5 temperature range. Residen-
tialheating/coolingsystemsaredesignedtomaintain
asettemperaturewithin thehome.Abigmisconcep-
tionthatpeoplehaveistoturnofftheirairconditioning/
heatingwhentheyleavethehome,andcrankitup/
downwhentheyreturnhome,thinkingthatthisisef -
cient.Foraresidentialheating/coolingsystemtobring
upordownthetemperaturedrasticallylikethis(forex-
ampleletssaymorethan5),thesystemwillhaveto
runmuchlongerthanitwouldhavethroughouttheday,
thereforeconsumingmorepowerandmakingitmuch
moreinefficient.
Hi-Velocity SystemsTM Controls and Operation
07
TM
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
10/12
Hi-Velocity Tools
Heat Load Calculator
Aswithanyheatingandcoolingpackage,Hi-VelocitySystemsTMrequireadetailedassessmentofthestructure,
ambientoutsidetemperaturesandotherfactorsthatarecriticaltoensurethatthesystemisproperlysizedformaximum
efciency.TheESPHeatCalculatorisdesignedtoprovidefastandaccurateloadcalculationstoeasethedesignof
Hi-VelocitySystems TM.Theinstallingcontractorhastheabilitytodesigntheappropriatesystemandprovidealayout.If
thecontractorwishes,hecanhavethewholesalerdesignthesystem,orsendittothefactoryforsizing.
Quick Quote Calculator
TheQuickQuoteProgramhasbeendesignedtoallowforsimpliedquotingoftheHi-VelocitySystem.Itenablesthe
usertoeasilyobtainpricingandproductcodesonthemainHi-Velocitycomponents.
08
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
11/12
Hi-Velocity Space SaverFan Coil, so compact it
cantinacloset
5 Possible Supply take-offstochoosefrom.
Usable with dual purpose hotwater heater, boiler, and heat
pumpapplications.
Round Supply Plenum
Flexible Supply ducts
Patented AdjustableRough-In Boot, Quick
and Easy to Install
Space Saver Hi-Velocity Fan CoilWhenEverySquareFootCounts
-
8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version
12/12
www.hivelocity.com
Phone: (780)453-2093
Fax: (780)453-1932
TollFree: 1-888-652-2219
Why Choose the Hi-Velocity System?WeatEnergySavingProductsLtd.workhard tocontinuallyimproveuponourselvesandour
products.Webelievetheproductsarearepresentationofourcharacter,withtheenduseralwaysinmind.OurteamofprofessionalsintheSmallDuctHighVelocityindustryarealwaysadaptingandinventingnewtechnologiestoprovideoptimalsolutionsforourcustomers.
Our TeamEnergySavingProductsLtd.,establishedin1983,manufacturestheHi-Velocity SystemsTMproduct
line forresidential, commercialandmulti-familymarkets.OurfacilitieshouseAdministration,Sales,Design,Manufacturing, aswell asResearch & Development complete with an in-house test lab.EnergySavingProductspridesitselfonCustomerServiceandprovidesdesignservicesandcontractorsupport.
Comfort from floor to ceiling,
Satisfaction from room to room,
with
Its not just a dream, its reality.
ESP 214
TM
HARDI