    What are Hi-Velocity SystemsTM? Hi-Velocity Applications Science of Hi-Velocity SystemsTM

    How Hi-Velocity Cooling Works Printed Circuit Board Controls and Operation Hi-Velocity Tools

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    2/12

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    3/12

    TheHi-VelocitySystemisahighpressureforcedair

    deliverysystemthatcanbedesignedtoprovideheating,

    cooling, ltration, ventilation, and humidication.The

    Hi-VelocitySystemhasbeenpre-engineeredandworks

    ontheprincipleofpressureratherthanairvelocity.

    TheHi-VelocitySystemdoesnotmakeorbreakanyexisting laws;it just uses those lawsdifferentlythana

    conventionallowvelocitysystem.Itisquitedifferentfrom

    aconventionalfurnace,themaindifferencebeingthatthe

    supplyductworkisallsmalldiameterorminiduct.

    Because the plenum duct is pressurized, dust

    build-up within the duct work is eliminated. With

    continuousaircirculationfromtheconstantfan,airborne

    dustandotherallergenscanbeeasilylteredoutofthe

    air.Withapressurizedsmalldiameterductwecondition

    theairdifferently thanconventionalforcedairsystems.

    With the use of a high pressure area to lowpressure

    area,wecontinuously mix the roomair, creatingeven

    temperaturesfromoortoceiling.

    Our Coolingmodules are highly efcient and very

    effectiveatremovingmoisturefromtheair.Notonlydo

    wecooltheair,weusealowerairvelocitywhichallows

    theHi-VelocitySystemtoremovemoremoisturefromthe

    passingairmolecules.

    TheHi-VelocitySystemachievesa superior Indoor

    AirQuality(IAQ)withan innovativefancoilandcooling

    moduledesign.Thistechnologyhelpscreateahealthier

    andmore enjoyable indoor living environment for the

    end-user.

    The key to Hi-Velocity SystemsTM -How we Provide these Benets:

    Hi-Efficiencyprogrammableenergysmartmotors

    Ourfancoilunitsaremodular,conveniently located,

    andcanbeinstalledinavarietyoforientations

    Roundplenumductforeasyinstallation

    Our2&HEflexductdeliversairunderagreater

    pressurethanaconventionalsystem.Thisincrease

    inpressureforcesthemixingoftheairintheroom,

    eliminatingstratication

    Our flex duct is insulated to prevent heat

    loss/gainandhasasoundabsorbinginnercoreto

    delivertheairwhisperquiet

    Smaller duct also allows for greater flexibility in

    installationswhilesavingspace

    Vents are adjustable andcan be installed in the

    floor,ceilingorwallinavarietyofstylestoblendin

    withtheirsurroundings.

    IAQHi-Velocity SystemsTM Improve

    Indoor Air Quality

    In the last several years, scientic evidence ha

    indicated that the air within homesand otherbuilding

    can containmorepollutants than the outdoor air.Wit

    peoplespendingapproximately90percentoftheirtim

    indoors,thehealthrisksmaybegreatertoexposureo

    airpollutionindoorsthanoutdoors.Peoplewhomayb

    exposedtoindoorairpollutantsforthelongestperiodso

    timeareoftenthosemostsusceptibletotheeffects.Such

    groupsincludetheyoung,elderly,chronicallyill,orpeople

    sufferingfromrespiratoryorcardiovasculardisease.

    Hi-VelocitySystemsTMcanprovidetheanswerstoa

    your IndoorAirQuality needs. TheHi-Velocity Systemutilizes a constant fan for air delivery which can hel

    eliminate conditionsthat promotemoldandmildew.B

    controllingyourenvironmentwithcontinuousaircirculatio

    and moisture control, conditions that will allow thes

    harmfulsporestheopportunitytotakeholdarereduced

    Forpeopledealingwithrespiratoryorcardiovascula

    disease, the Hi-Velocity System can easily beused i

    conjunction with add on ltration equipment. With th

    versatilityofourunits,charcoal,electronic,electrostatic

    andhepaltersareeasilyaddedontoprovideyouwit

    acleanerandhealthierlivingenvironment.Whendealin

    withmoisture,humidiers,de-humidiers,andatomizer

    canallbeusedinconjunctionwiththeHi-VelocitySystemFreshaircanbesupplieddirectly,orindirectlythroughthe

    useofaheatexchanger.

    How the Hi-Velocity System can -

    Improve your Indoor Air Quality:

    Eventemperaturethroughoutthestructure

    Filtration

    Freshairmake-up

    Humidication

    Dehumidication

    Reduceconditionsthatpromotemoldandmildew

    What are Hi-Velocity SystemsTM?

    01TM

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    4/12

    Commercial Multi-Family New Construction Retrofts

    Applications for Hi-Velocity SystemsTM

    The Hi-Velocity System can be utilized for most

    projects,butsome typical installationsarecommercial,

    multi-family, new housing construction and the retrot

    market.Withtheversatility,quickinstallationandsuperior

    IndoorAirQualityprovided fromour systems, theyare

    nowapopularchoicewithhomebuilders,installersand

    theenduser.

    Commercial

    In commercial applications, exposed plenum with

    drilled outlets is the ideal choice. Drilled outlets are

    commonlyusedtosupplyalargeareawithheatingand

    cooling.Theycanalsocreateapressurizedaircurtainfor

    baydoorsorlargeopeningstotheoutsideenvironment.

    Multi-Family

    Manybuilding contractorsareutilizingourspecially

    designed HV-52 units for multi-family structures. The

    Space Saver model is the same as other Hi-Velocity

    SystemsTMwiththeexceptionofthesupplyairtake-off.It

    wasdesignedforclosertake-offpoints.Thismodelcomes

    with 5 available supply outlet locations, four 6 supply

    outletsandone8outlet.Withtheadaptabilityofthisunit,

    itwill t inalmostanycloset,crawlspace, oranywhere

    elsewherespaceisanissue.

    New Construction

    When you want to improve your living standards,

    theHi-VelocitySystemistherightchoiceforcoolingand

    heating.Whywastespaceframingout largeduct runs

    reducingtheyourlivableareawhensmallroundplenum

    and exibleductscanberun throughoors,wallsandceilings.Notonlywillyou improveyourlivingstandards

    with the Hi-Velocity SystemsTM, they save you space

    allowingyoutoenjoyyourhomethatmuchmore.

    Retrofit

    In older homesupgrading the heating and cooling

    system, there is no better choice than the Hi-Velocity

    System.Thesmallductsareeasytopullthroughwalls,

    oorsandceilingswithverylittlechangestotheexisting

    structure.

    Features of the Hi-Velocity System

    UnitPre-assembledfromthemanufacturer

    MassowVariableFrequencyDrives

    -6independentspeeds

    AutomaticVoltage&FrequencyRecognition.

    110/230volts,50/60cycles

    Flexibilityinunitlocation;canbemountedVertical,

    HorizontalorintheCounterFlowposition

    CoolingandHeatingmodulescaneasilybeadded

    toanyunitatthetimeofpurchase,orlaterasan

    upgrade

    LargeselectionofHeatingandCoolingmodules:

    WaterCoolingmodules

    RefrigerantCoolingModules

    WaterHeatingCoils

    ElectricStripHeatingCoils

    HeatPumpcompatible

    8and10RoundPlenummakesinstallationeasier

    andincreasesusablespace

    Ourpre-assembledexible2&HEductisavailable

    in10and15standardlengths

    Flexible2&HEductextensionkitsforlongerruns

    Ventscanbeadjustedfornetuning

    Varietyofventplatestomatchanydecor

    SingleSideAccessforeasymaintenance

    AdjustableTXvalve

    Compatiblewithmostcommonrefrigerants

    Easilyadaptabletothirdpartyequipment

    02

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    5/12

    CalvinDoddMacCracken(1920-1999),anengineer

    andinventorfromNewJersey,iscreditedwithbuilding

    the first highvelocitystyle airhandler, usingsmall

    insulatedductsto deliver heatedair at considerable

    pressureandhighvelocity.Thissystemquicklygained

    inpopularity,andaspublicinterestgrew,acompany

    cal led Space Conditioning Inc. incorporated theMacCracken Forced-Air House Heating Apparatus

    (Patent 2,488,548) into theirproduct lines. Thisunit

    later became known as the Jet-Heet System. The

    primarymarketforthesystemwasretrofitcoolinginto

    homesthathadlittleroomforductworkorinwhich

    architecturalchangeswereundesirable.MacCrackens

    airhandlerwasbasedontwoscientificprinciples:

    Bernoullis Principle: (DanielBernoulli 1700-1782)Wherethereisdecreasedflow,youwillfindincreased

    pressure.Wherethereisincreasedflow,youwillfind

    decreasedpressure.

    Venturi Effect: (GiovanniBattistaVenturi1746-1822)The increase in the velocity of a fluid stream as it

    passesthroughaconstrictioninachannel.Calculated

    by the Continuity Equation Q = VA where Q is the

    volumetricflowrate,AistheareaofflowandVisthe

    fluidvelocity.BecauseQdoesnotchange,asAgets

    smallerthenVmustincrease.

    Bernoullis Principle

    Bernoullis Principle plays an important part in the

    operationoftheHi-VelocitySystem.Toillustratehowthis

    works,letslookatthedynamicsofashowerhead.With

    the showerhead in place, you create pressure in thepipingandmoveasmallamountofwaterquicklythrough

    the showerhead holes, with the water being equally

    distributedtoeachhole.Ifyouremovetheshowerhead,

    youremovethepressure,andbeginmovingalotofwater

    slowlyandinonebigstream.Ittakesthesameamountof

    energytomoveasmallamountofwaterquickly,asitdoes

    tomovealargeamountofwaterslowly.Theamountof

    energyyouhaveavailabledependsonyourwaterpressure.

    Thesmallholesintheshowerheadcreateapressurepoint

    inyourwaterline,makingthewatermovingthroughthat

    piperetainahighpressureandlowvelocity.Oncethewater

    leavestheshowerhead,itisnolongerunderpressure,so

    thevelocityincreases.

    Thisisverysimilartohowtheairowworkswiththe

    Hi-VelocitySystem.Ourfancoilpressurizestheductwork

    justlikethewaterpipeofyourshower.Ourventoutletsact

    liketheholesintheshowerheadtoconvertthepressure

    tovelocity,anddelivertheconditionedairtoyourhome.

    Sinceairowandwaterowfollowthesameprinciples,

    youwillgetequalairowfromalloftheHi-VelocitySystem

    ventsinyourhome.Thisholdstruefromtherstbranch

    ducttothelastone,andismodiedonlyduetofriction

    fromlongerlengthsofbranchducts.

    Thesystemmaintainsahighpressurewithintheduct

    which results in a low air ow within the duct work.

    Whenreleasedfromtheduct,thispressureisconverted

    tovelocityattheoutlet,goingfromahighpressurearea

    toalowpressurearea(theopenroom).Thehighervelocity

    oftheairleavingtheductforcestheairwithintheroom

    tomixbasedontheVenturiEffect.

    Venturi Effect

    Whenthehigher-pressureairleavestheventofthe

    Hi-VelocitySystem,itexpandsrapidlyandcausesalower

    airpressurearoundthevent.Thiscausestheroomairto

    bedrawntowardtheairstreamthatisleavingthevent.By

    applyingtheVenturiEffect,theHi-VelocitySystemcauses

    thethoroughandcontinualmixingofroomair,eliminating

    the possibilityof hot and coldspotsfromdeveloping in

    thehome.Withotherairsystemsthatoperatewithless

    pressure, this effect doesnot occurto any appreciable

    amount.WiththeHi-VelocitySystem,whethertheventsarelocated in theoor, ceiling orwall, complete and

    consistentmixingoftheairwillalwaysoccur.Toallowfor

    customlevelsofcomfort,everyventhasabuilt-indamper,

    makingiteasytocontrolindividualroomtemperatures.

    Vent Outlet Utilizing the Venturi Effect

    The Science and History of Hi-Velocity Systems

    03

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    6/12

    Witha conventional lowvelocity forced air-cooling

    system,therulethateveryoneknowsisavolumeof400

    CubicFeetofairperMinute(CFM)foreachton.With

    400CFMatalowstaticpressure,andalargefacearea

    /thindepthcoil,theairiscooledandasmallamountof

    humidityisremoved.WiththeHi-VelocitySystem,weusealowerCFMbuthigherstaticpressuretoaccomplishthe

    sameamountofcooling, removingmore humidity from

    theairintheprocess.

    400CFMisadesignruleforconventionalheating

    systemsandwillputanoptimumloadontheindoorcoil.

    This allows the coil toproperlyevaporate refrigerant

    andperformheattransfer.Sinceconventionalheating

    systems use a lower pressure than Hi-Velocity

    SystemsTM,ahigherairowisneededtoprovideenough

    massofairtoperformtheheattransfer.Inversely,the

    more pressure that the air isunder, the lessCFM is

    needed.How thisworks ison the microscopic level;the amount ofair molecules present through the coil

    determineshowmuchheattransferisdone.Undera

    higherpressuretherearemoreairmoleculespresentper

    cubicfoot.TheHi-VelocitySystemrequireslessCFMof

    airtopassthroughtheevaporator,whilestillproviding

    thesamecoilload.

    Withasmuchcoilload(ifnotmore)passingthrough

    theevaporator,equalorsuperiorcoolingwillresult.An

    additionalbenettomovingmoreairmoleculesthrough

    thecoilatalowerrateisthelatentcooling.Sincethe

    air passing through the coil is in contact with the coil

    surfaceareaforalongerperiodoftime,thetemperature

    isdroppedlowerthanwithconventionalsystems,thus

    reducingtheairsabilitytoholdmoisture.Ourcoilshave

    aunique design; theyare highly efcientand typically

    thicker than coils in conventional cooling systems.

    Withourstyleofcoolingcoilwewillremoveuptothirty

    percentmoremoisturefromtheair.Thishasthebenet

    ofallowinga greater thermal comfort level, even ata

    highertemperature.

    Airvelocitycanbeeitherahelporahindranceto

    thermal comfort levels. While a small amount of air

    movement isdesirable toincreasetheskinevaporationrate, ithasto beauniformmovementover the entire

    body in order to provide benets to thermal comfort

    levels.Anylargeamountsofdirectairvelocityovera

    part of the humanbodywill causean uneven rate of

    evaporationandheattransfer.Thisiswhytheventsfor

    theHi-VelocitySystemareusuallylocatedinlowtrafc

    areassuchascornersofaroom,ortothesidesofdoors

    andwindows.Bylocatingtheventsintheseareas,the

    amountofdirectairmovementthathumanswillcomein

    contactwithwillbeminimized,sincetheventshaveonly

    aneight-inchconeofdirectinuence.

    Airtemperature,humidity,anddirectairvelocityare

    the factors that will cause the most change to thermal

    comfortlevels.Mostpeoplebelievethatcoldairisthekey

    factorforagoodairconditioningsystem.Consideringthat

    thehumanbodyhasanaturalcoolingsystembuiltin,the

    keytocreatingacomfortableenvironmentforthehumanbodyistocreatetherightcombinationofenvironmental

    factors.

    Parameters that describe thermal comfort.

    Airtemperature

    Wet-bulbtemperature

    Dewpointtemperature

    Watervaporpressure

    Totalatmosphericpressure

    Relativehumidity

    Humidityratio

    Airvelocity

    Meanradianttemperature

    Airtemperatureis onlythestartingpoint increating

    a comfortable environment. By reducing the inside air

    temperatureto 70Fa personmaybecomfortable toa

    certaindegree.However,inahighhumiditylocation,youcouldstillhavetheclammyfeelingduetoallthemoisture

    intheair.Thebodywillnaturallyevaporatethismoisture,

    whichcouldleadtoacolduncomfortablefeeling.When

    thehumidityleveliscontrolledataproperlevelaperson

    canbecomfortableatahigherindoortemperature.With

    noevaporationontheskinsurfacebeingexperienced,no

    heattransferwillbetakingplace,allowingtheindividualto

    enjoyaconstanttemperatureontheskinsurface.

    Airvelocitywithinaroomcanalsohaveabigeffect

    on comfort. When not enough airow is introduced,

    straticationandroomseparationmayoccur.Stratication

    isthelayeringofhotandcoldair;hotairwillalwaysrise

    andcanresultinabigtemperaturedifferencefromoor

    toceiling.In conventionalsystemswhichusethe throw

    anddiffusionmethod,separationcanoccurfromoneside

    ofthe roomtotheother,withtheair closer tothevent

    usually being colder. Both stratication and separation

    happenwhenthereisnomeansofcirculatingtheroomair.

    TheHi-VelocitySystemprovidesconstantair circulation

    throughtheVenturiaffect,neverallowingstraticationor

    roomseparationtooccur.

    How Hi-Velocity Cooling Works

    04

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    7/12

    TheHi-VelocityCircuitboardmakeswiringoftheun

    aquickandsimpletask.Withclearlylabeledconnections

    itiseasytowireinthethermostat,condenserandanti-

    icecontrol.WithourAuxiliaryRelayandDry Contac

    connections,anyapplicationthatrequires24volt,110

    volt,230volt,ordrycontacts(boilers,hotwaterheaters,

    heatpumps,humidiers)canbeautomaticallystarted

    when there is a call for heat. When the Hi-Velocity

    Systemisusedtosupplementradiantoorheating,the

    HotWaterZoneValveterminalsautomaticallyactivate

    thezonevalves.

    Timer Chip

    Theprintedcircuitboardwithinthefancoilcontainsa

    timercircuit. On some systems(when applicable), this

    timer will cycle the pump on potable water systems

    to ush the water through the system during summe

    monthsandpreventanystagnation.Thetimercircuitis

    equippedwitharedashinglightinthecenterofthecircui

    board.Itisnormalfortheredlighttobeashingasitis

    showingusthatpowerisbeingsuppliedtotheunit.

    EPC Circuit Board

    05

    Circuit Board Features:Automatic voltage and frequency recognition circuitry,

    115 or 230 volt, 50 or 60 cycle, our electronics will

    adjusttotheinputautomatically.

    protectedwithanintegralsurgeandfusesystem.

    Built-in 2 stage heating/cooling terminals

    Dehumidiersequenceprogram

    A constant fan operation that can now be controlled

    from the thermostat

    potable water timer circuit

    20 va transformer is built into the circuit board for

    auxiliaryuses

    Auxiliary heating relay is included for dry contact

    applications.

    Thermostat terminals follow industry standards for

    easeofinstallation.

    Terminalsforyour;

    Heatingzonevalve,

    Coolingcondensingunit,

    Anti-icecontrol,

    B/O heat pump

    Neutral C terminal

    aresuppliedtosimplifytheeldcontrolwiring.

    Dynamic pump duty cyclechip provided toprevent

    water stagnation in potable water systems and to

    providepumprotorprotection.

    Auxiliary Relay

    Connections

    Line Voltage

    Control InterfaceLow Voltage

    Control Interface

    Thermostat

    Connections

    20 VA TransformerTimer On/O SwitchTimer Chip

    Hot Water

    Zone Valve

    Condensing

    Unit

    Anti-Ice

    ControlEPC Circuit

    Board

    The Circulator Timer Chip on our circuit board wil

    energize thepump for5 minutesevery24hours.This

    timingcyclestartswhenpower is turnedon tothe fan

    coilunit,andwillbeengagedatthesametimeeveryday

    Ifyouwishtohavethetimercycleoperateataspecic

    timeofday,simplyturnoffpowertothefancoilunitfor

    threesecondsatthattime,andthenturnthepowerback

    on.Ifyoudonotneedtousethetimercircuit,movethe

    jumperheaderfromtheONpinstotheOFFpinsandit

    willbedisabled

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    8/12

    Control Board Features

    Hi-Velocity-HE Systems areeld programmable from

    1.5to5tonsofcooling

    Each programmed tonnage will have up to 5

    adjustments

    FastandSimpleOn-sitenetuning Themotorandcontrollerareseparateunitsandrequire

    norecalibration

    Heating Mode

    Boilers,hotwatertanks,heatpumps,andgeothermal

    systemscanallbeusedasheatsourcesfortheHi-Velocity

    System.Wealsomanufactureaslide-inelectricstripcoil

    thatisavailableforusewiththesystem,easilyinstalled

    withoutanyexternalmountingorductworkrequired.

    Whentheunitisinheatingmode,theAuxiliaryrelayisalso engaged.Themost common use for this relay

    is to start a circulator pump for heating; however, the

    auxiliary relaycanbe used for110volt,24 volt,ordry

    contact operationdependinguponyourneeds.Also in

    heatingmode,24voltpowerissuppliedtotheZoneValve

    Terminalsincaseyouhaveanormallyclosedzonevalve

    withyourfancoil.Withmorepeopleusingradiantoor

    heating,ourcircuitboardreducestheuseofthirdparty

    relays resulting in a faster installation and helping the

    installertodiagnoseanyproblemsinthefuture.

    Thecirculatortimerchip onour circuit boardwil

    energizethepumpfor5minutesevery24hours.This

    timingcyclestartswhenpoweristurnedontothefan

    coilunit,andwillbeengagedatthesametimeeveryday.

    Ifyouwishtohavethetimercycleoperateataspecictimeofday,simplyturnoffpowertothefancoilunitfo

    threesecondsat that timeofday,thenturnthepowe

    backon.Ifyoudonotneedtousethetimercircuit,the

    jumperheadercanbechangedfromtheONpositionto

    theOFFpositionanditwillbedisabled.

    Cooling ModeCondensing units, chillers, heat pumps and

    geothermalsystemscanallbeusedascoolingsources

    fortheHi-VelocitySystem.

    Whenthefancoilgoesintocoolingmode,themoto

    switchestothedesiredcoolingspeed,eitherHi-Cooling

    orLo-Cooling.Properairowisveryimportantwhenthe

    unitiscooling,andourprintedcircuitboardensuresthe

    motorspeedisalwayscorrect.Incoolingmode,24vol

    powerissuppliedtotheCondenserUnitterminalswhich

    starts the outdoor condenser. This power rst passes

    throughtheFreezeStatterminals,ensuringtheunitisin

    areadystate.

    EPC Control Board

    06

    Low VoltageInterface

    Line VoltageInterface

    MotorInterface

    Dip SwitchProgrammable Settings

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    9/12

    System Operation

    OntheHi-VelocitySystemHEmodel,thefancoil

    unithassixindependentmotorspeeds;

    Hi-Cooling

    Lo-Cooling

    Dehumidication

    Hi-Heating

    Lo-Heating

    ConstantFan

    Cooling Automatically Controlled

    WhentheHi-VelocitySystemswitchestoCooling

    mode,themotorisautomaticallysettohighspeed,to

    ensureproperairowacrossthecoil.Thiswillresultin

    thebestpossiblecoolingandmoistureremovalfromthesystem.

    Potable Water Timers

    InrecognitionofconcernsexpressedbyPlumbing

    Inspection Departments, Engineers, Home Builders,

    Home Owners, and Installing Contractors, the Hi-

    VelocitySystemoffersatimerprocessorwhichcanbe

    enabledonourprintedcircuitboard.Thisallowswater

    from an approved dual purpose water heater to be

    circulatedforaveminuteperiodevery24hours.

    The timer processor overcomes the possible

    concern ofwatercontaminationwithin the system. It

    alsohastheaddedbenetofdutycyclingthecirculator

    everyday,eliminatingalockedrotorwhichissometimes

    experiencedduring long shutdownperiodsonwater

    lubricatedcirculators.Thetimeoperationcanbesetat

    anytimebydisconnectingthe110voltpowersourceto

    thefancoil,andthenre-connecting.Eachtimepower

    isappliedtotheunit,thetimeractivatestheveminute

    override,conrmingoperation.

    Evenonclosedloopboilersystems,thetimerprocessorcan be benecial. In a closed loop system, water

    contamination is not a concern, but duty cycling the

    zoning controls will increase the life expectancy of

    thosecontrols. Inadditionto helpingto reducelocked

    rotorsoncirculators,theprocessorwillalsodutycycle

    hydronic zone valves.Approximately80%ofall zone

    valvefailurecanbedirectlyrelatedtostuckportsdueto

    offseasonbuildup.Thetimerprocessorwasdeveloped

    fromconsumer inputandcangreatly increasesystem

    reliability.

    Constant Fan Control

    TheConstantFanControlisenabledwhenthereis

    nodemandforheatingorcoolingfromthethermostat.

    Itisoptionalandcanbeturnedoffifnotdesired.

    Thereisgreatbenetwithusingthisconstantfan

    control.Itprovidesltrationcontinually,andcanalso

    helpreduceyourenergycostsforyourhomebygently

    stirringtheairwithinyourhomeconstantly.Thiscan

    eliminate hot and cold spots(stratiedair) that can

    commonlyoccurwithconventionalsystems,andcan

    save you energy as it prevents the majority of the

    heataccumulatingattheceiling,creatingamoreeven

    temperaturethroughoutthehome.

    System Efciency/Performance

    Theconstantfanreducestheamountofstratication

    withinthehome,andevenwiththeheating/coolingoff

    itcangiveyoumuchmoreeventemperaturesbetween

    oors. This feature basically gives you a constant

    stirring effect of the air throughout the house. The

    amountofpoweractuallyusedwiththisconstantfan

    operationisaboutthesameasa100wlightbulb.

    WiththeHi-VelocitySystemyouwanttomaintain

    your housewithin a 5 temperature range. Residen-

    tialheating/coolingsystemsaredesignedtomaintain

    asettemperaturewithin thehome.Abigmisconcep-

    tionthatpeoplehaveistoturnofftheirairconditioning/

    heatingwhentheyleavethehome,andcrankitup/

    downwhentheyreturnhome,thinkingthatthisisef -

    cient.Foraresidentialheating/coolingsystemtobring

    upordownthetemperaturedrasticallylikethis(forex-

    ampleletssaymorethan5),thesystemwillhaveto

    runmuchlongerthanitwouldhavethroughouttheday,

    thereforeconsumingmorepowerandmakingitmuch

    moreinefficient.

    Hi-Velocity SystemsTM Controls and Operation

    07

    TM

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    10/12

    Hi-Velocity Tools

    Heat Load Calculator

    Aswithanyheatingandcoolingpackage,Hi-VelocitySystemsTMrequireadetailedassessmentofthestructure,

    ambientoutsidetemperaturesandotherfactorsthatarecriticaltoensurethatthesystemisproperlysizedformaximum

    efciency.TheESPHeatCalculatorisdesignedtoprovidefastandaccurateloadcalculationstoeasethedesignof

    Hi-VelocitySystems TM.Theinstallingcontractorhastheabilitytodesigntheappropriatesystemandprovidealayout.If

    thecontractorwishes,hecanhavethewholesalerdesignthesystem,orsendittothefactoryforsizing.

    Quick Quote Calculator

    TheQuickQuoteProgramhasbeendesignedtoallowforsimpliedquotingoftheHi-VelocitySystem.Itenablesthe

    usertoeasilyobtainpricingandproductcodesonthemainHi-Velocitycomponents.

    08

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    11/12

    Hi-Velocity Space SaverFan Coil, so compact it

    cantinacloset

    5 Possible Supply take-offstochoosefrom.

    Usable with dual purpose hotwater heater, boiler, and heat

    pumpapplications.

    Round Supply Plenum

    Flexible Supply ducts

    Patented AdjustableRough-In Boot, Quick

    and Easy to Install

    Space Saver Hi-Velocity Fan CoilWhenEverySquareFootCounts

  • 8/7/2019 ESP 214.04b Hi-Velocity Explained, HE Online Version

    12/12

    www.hivelocity.com

    Phone: (780)453-2093

    Fax: (780)453-1932

    TollFree: 1-888-652-2219

    Why Choose the Hi-Velocity System?WeatEnergySavingProductsLtd.workhard tocontinuallyimproveuponourselvesandour

    products.Webelievetheproductsarearepresentationofourcharacter,withtheenduseralwaysinmind.OurteamofprofessionalsintheSmallDuctHighVelocityindustryarealwaysadaptingandinventingnewtechnologiestoprovideoptimalsolutionsforourcustomers.

    Our TeamEnergySavingProductsLtd.,establishedin1983,manufacturestheHi-Velocity SystemsTMproduct

    line forresidential, commercialandmulti-familymarkets.OurfacilitieshouseAdministration,Sales,Design,Manufacturing, aswell asResearch & Development complete with an in-house test lab.EnergySavingProductspridesitselfonCustomerServiceandprovidesdesignservicesandcontractorsupport.

    Comfort from floor to ceiling,

    Satisfaction from room to room,

    with

    Its not just a dream, its reality.

    ESP 214

    TM

    HARDI