erosion and sediment control details

1
NORTHING 1951548.1581 EASTING 6344964.4671 NORTHING 1951570.1412 EASTING 6345378.1405 NORTHING 1951571.0356 EASTING 6345278.1445 NORTHING 1951517.1430 EASTING 6345040.3437 NORTHING 1951520.1432 EASTING 6345377.6933 NORTHING 1951574.6381 EASTING 6345060.8975 NORTHING 1951518.6864 EASTING 6344972.5601 100-FT 30-FT 100-FT 50-FT 0+00 1+00 2+00 2+05 220 230 240 250 260 270 280 260 260 270 270 280 280 290 220 230 240 250 260 270 280 290 280 270 250 280 230 240 260 250 240 CD CD SITE PLAN N SCALE IN FEET 0 20' 40' 60' SCALE: 1" = 20' EXISTING TRANSMISSION TOWER PROPOSED PULL SITE PROPOSED 12-FT WIDE ROAD CAD FILE: C:\pwworking\kleinfelderpw01\kleinfelder_msnyder\d0181832\03_Shiloh Park_Site Plan.dwg LAYOUT: 4 GRADING PLAN PLOTTED: 7/17/2018 1:17 PM BY: maria snyder DESIGNED BY ISSUE DATE CURRENT REVISION DRAWN BY CHECKED BY PROJECT NO. REVISIONS 1" 0 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY APPROVED BY ORIGINAL DRAWING SIZE IS 24 x 36 07/13/2018 A M. SNYDER M. SNYDER A. BISACKY 20190767 FULTON-FITCH ALIGNMENT RE-CONDUCTOR PULL-SITE SHILOH PARK PACIFIC GAS & ELECTRIC COMPNAY 6121 BOLLINGER CANYON ROAD SAN RAMON, CA 94583 REV DESCRIPTION DSN CHK DATE DWN APP A ISSUED FOR REVIEW MRS AB 7/13/2018 MRS AT 40 Clark Street, Suite J Salinas, CA 93901 Phone: 831-755-7900 www.kleinfelder.com A. TRAUM GRADING PERMIT PLANS PROPOSED PULL SITE EXISTING TRANSMISSION LINE (TYP) TOP OF BANK EXISTING STREAM MEAN HIGH WATERLINE PROPOSED CONSTRUCTION ENTRANCE PROPOSED CHECK DAM AT 25-FT (TYP)

Upload: others

Post on 20-Oct-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EROSION AND SEDIMENT CONTROL DETAILS

NORTHING 1951548.1581EASTING 6344964.4671

NORTHING 1951570.1412EASTING 6345378.1405

NORTHING 1951571.0356EASTING 6345278.1445

NORTHING 1951517.1430EASTING 6345040.3437

NORTHING 1951520.1432EASTING 6345377.6933

NORTHING 1951574.6381EASTING 6345060.8975

NORTHING 1951518.6864EASTING 6344972.5601

100-FT

30-FT

100-FT

50-FT

0+001+00

2+002+05

220

230 240

250 260 270

280

260

260

270

270

280

280

290

220

230

240 25

0 260 27

0

280

290

28027

0

250

280

230

240

26025

0

240

CD CD

SITE PLAN

N

SCALE IN FEET

0 20' 40' 60'

SCALE: 1" = 20'

EXISTINGTRANSMISSIONTOWER

PROPOSED PULL SITEPROPOSED 12-FT WIDE ROAD

CA

D F

ILE

: C

:\pw

wor

king

\kle

infe

lder

pw01

\kle

infe

lder

_msn

yder

\d01

8183

2\03

_Shi

loh

Par

k_S

ite P

lan.

dwg

L

AY

OU

T: 4

GR

AD

ING

PLA

NP

LOTT

ED

: 7

/17/

2018

1:1

7 P

M B

Y: m

aria

sny

der

DESIGNED BY

ISSUE DATE

CURRENT REVISION

DRAWN BY

CHECKED BY

PROJECT NO.

REVISIONS

1"0

SCALE VERIFICATION

THIS BAR IS 1 INCH IN LENGTHON ORIGINAL DRAWING

IF IT'S NOT 1 INCH ON THISSHEET ADJUST YOUR

SCALES ACCORDINGLY

APPROVED BY

ORIGINAL DRAWING SIZE IS 24 x 36

07/13/2018

A

M. SNYDER

M. SNYDER

A. BISACKY

20190767

FULTON-FITCH ALIGNMENT RE-CONDUCTOR PULL-SITE

SHILOH PARK

PACIFIC GAS & ELECTRIC COMPNAY6121 BOLLINGER CANYON ROAD

SAN RAMON, CA 94583

REV DESCRIPTIONDSN CHK

DATEDWN APP

A ISSUED FOR REVIEWMRS AB

7/13/2018MRS AT

40 Clark Street, Suite JSalinas, CA 93901

Phone: 831-755-7900www.kleinfelder.com

A. TRAUM

GRADING PERMIT PLANS

PROPOSED PULL SITE

EXISTINGTRANSMISSIONLINE (TYP)

TOP OF BANK

EXISTING STREAMMEAN HIGH WATERLINE

PROPOSED CONSTRUCTION ENTRANCE

PROPOSED CHECK DAM AT 25-FT (TYP)

MSandomire
Callout
COARSE GRAVEL TO PREVENT TRACK-OUT