equipment description
TRANSCRIPT
Autoclave Fully automatic vertical steam sterilizers
PURPOSE OF AUTOCLAVE
Liquids such as nutrient media and buffer solutions Solid items such as pipette tips, tubes and filters Glassware and plastic articles Biohazard sterilization
CONTROL AND DOCUMENTATION FEATURES
In addition to a comprehensive LCD display: Password protection for operating machine. Independent temperature and pressure monitoring Cycle information recovery in the case of power failure or cycle interruption Fail Alert – Indicating cycle failure or interruption Door Alert – Indicating the door is unlocked RS 232 PC Connection Port for direct software updates and remote maintenance SAFETY FEATURES
Door Safety
Safety Valves
Built-in Steam Generator Safety
Safety alarms
Drain Protection:
Type Chamber Dimensions (ø x depth) (in mm)
Chamber Volume (in Liters)
External Dimensions (W x H x D) (in mm)
3850 ELV 380 x 490 62 650 x 745 x 500
LAB WATER BATH
Digital display
5L capacity; 120V 50/60Hz, 2.5A
Dimensions: 13L x 16W x 9D
Weight:16 lbs
Microprocessor PID Control
±0.24°C uniformity, ±0.5°C accuracy and stability at 37°C
Display shows both °C or °F Safety Features
Low profile and front-panel controls for easier access, safer operation
Dual thermostats guard against thermal runaway
Hinged acrylic or stainless-steel gable covers having fins that keep hands away from hot vapors
Covers that stay open at 90° or, with quick-release hinge, lift off completely for use with large glassware
Heating elements should not burn out if bath accidentally runs dry
Construction
Corrosion-resistant exterior with tough, easy-to-clean acrylic enamel coating
Temperature-resistant plastic rim insulates, that resist leaks, keeps its shape and won't dry out or crack like caulked seals
Exterior stays cool even after hours of operation Deep-drawn, stainless-steel reservoirs and perforated sample trays which prevent leaks, guard against rust and contamination
Rounded reservoir corners and sample trays with finger holes that allow for easy removal, make cleaning easier
Choice of acrylic or stainless-steel covers
With drain pump to empty reservoir
Specifications
Temperature Range, Maximum w/Lid Ambient to 100°C (212°F)
Temperature Accuracy at 37°C ±0.5°C
Temperature Uniformity at 37°C ±0.24°C
Temperature Stability at 37°C ±0.5°C
Temperature Control/Display PID/Digital ft.
Electrical Requirements 120V 50/60Hz
Resolution ±0.1°C
ft.Microprocessor PID Control
Lab Research Microscope
Digital Binocular; Brightfield Contrast
Optics: Traditional Plan Achromatic or Infinity-corrected 4x, 10x, 40x, and 100x oil, parfocal, and parcentered, standard objectives with coating to reduce reflection
Head: Video Binocular, 45° observation angle with interpupillary and dual diopter adjustments
Camera: 640 x 480 analog or 3 megapixel color camera
Video: RCA video output and 6.4 in., 360° rotating LCD viewing screen (12-563-530 only)
Eyepieces: 10x, 20mm widefield with built-in, collapsible eye cups
Illumination: 6V, 20W halogen illumination with easy, pull-out cartridge bulb replacement system
Mechanical Stage: Low-position, X/Y axis mechanical stage
Electrical: 110V to 240V auto-adjustable power supply
Carrying Handle: Built-in carrying handle that makes microscope easy to move
Focusing Stop: Factory set and user adjustable to protect slides
General purpose freezer
Capacity: 20 cu. ft.; 115V, 60Hz
Dimensions:
Interior: 20D x 27W x 57’’H
Exterior: 36L x 32W x 73’’H
Weight: 200 – 220 kg
Adjustable temperature from -20° to -12°C, with ±3°C stability
Equipped with manual defrost for sensitive biological sample storage
CFC-free R404A refrigerant
Durable, textured white enamel-coated steel exterior Foamed-in polyurethane insulation
One solid hinged door opens to a 90° angle, closes with a gentle push
Four adjustable legs ensure cabinets are level on irregular floors
Lab Refrigerator
Dimensions: Interior: 52D x 27W x 18’’H Exterior: 65L x 32W x 29’’H
Thermostat control of temperatures ranging from 1° to 8°C with ±3°C stability
Capacity, 17 cu. ft. (481L) Automatic defrost
CFC-free (R404A) refrigerant, polyurethane insulation
White enamel-coated steel cabinet, white epoxy powder-coated steel interior
Solid door that has hinge mechanism that holds door open at 95° angle, closes with a gentle push
Four adjustable legs that ensure cabinet is level on irregular floors
fixed white epoxy-coated steel-wire shelves which can resist most acids, solvents, and chemicals; provide 13.5 sq. ft. of shelving
BIOSAFETY UNIT
Description:
Designed for biological agents at Biosafety Levels 1–3
Class II, Type A2 Biological Safety Cabinet Packages
4’’ package, 120V 50/60Hz
AC motored cabinet
sloped front, bright workspace, and low noise level
with Digital Airflow Verification
features like UV light, electrical points, gas points
Real-time airflow adjustments ensure inflow and downflow velocities remain steady
Meet NSF/ANSI™ Standard 49
Pressure sensor filter monitoring that measures total airflow across the working area
Proprietary front window design which simplifies cleaning for a safer working environment
Indicator to adjust airflows as filter resistance changes
SmartFlow visually demonstrates cabinet's ability to compensate to maintain personal
protection
Analytical balance
Weighing Range: 120g Readability: 0.1mg Repeatability: 0.1mg Linearity: 0.2mg Including: Universal power adapter, USB data cable, in-use cover, application guide, dust cover Simple menu navigation and integrated applications at the touch of a key Clearly visible icons fully automatic internal calibration and balance adjustment connectivity to a printer or computer Level control: Glass level indicator with air bubble for centering Calibration: Internal, fully automatic calibration with configurable action level Weighing units: g, ct, mom, kg, lb, oz, ozt, tls, tlt, GN, dwt, mg, parts/lb, tlc, Kt, tol, bat, MS, N Stability indicator Tamper protection lock Housing protection: Acetone cleanable housing Language selection: English, French, Theft lock Output: Mini-USB Power: 120V 60 Hz Weight: 12 lbs Dimensions: 5 x 7 x 18”
Iso-temperature lab incubator
Large; Chamber capacity: 5.0 cu. ft.
Power: 120V
30° to 75°C (86° to 167°F) range
Incubators with gravity flow circulation
Efficient heating for routine laboratory procedures: drying and staining of slides, microbiological
determinations, and more.
Electrical receptacle inside (5A at 120V) to plug in a stirrer, shaker or other apparatus.
with two shelves
Microprocessor control located at the top of the incubator chamber
decrease set point temperature adjustments in 0.1°C increments
Over temperature value is automatically set at 3°C above setpoint
Circuit breaker protection; battery backup
Heat and Alarm indicators
Cabinet with durable, enamel-coated steel exterior
Extruded aluminum trim has acrylic powder coating
Large LED display
Silicone gasket on outer door to prevent heat loss
Outer door opens to 180° for unhindered access and features two grabber-type latches
Inner door is tempered glass
rubber feet to keep incubator from slipping and maintain a space between incubator and
benchtop for ventilation
Accessories:
25mL (60 each), 125 mL (9 each), 500 mL (8 each), 1L (4 each ) and 2 L ( 4 each) flask clamps.
Microwell plate clamp
General purpose bench top centrifuge
g force (rcf): 100–3,000 x g (100 x g increments) Speed: 100–4,400 rpm (in 100 rpm increments) Maximum capacity: 4 x 85 mL or 30 x 15 mL Number of rotors: 6 Acceleration time: <25 s Braking time: <25 s soft brake function Timer: 0–99 min, with continuous mode Power supply: 120 V/50–60 Hz Dimensions: (W x D x H) 12.5 x 15.6 x 9.5 in/32 x 40 x 24 cm Height: with lid open 20.7 in/52.5 cm Weight: 44 lb/20 kg 4 x 85 mL swing-bucket rotor with round buckets 4 adapters for 15 mL conical tubes and 4 adapters for 50 mL conical tubes
High purity water system
Reservoir: 30L reservoir made up of Polyethylene material with minimum release of extractables Compact, space-saving design Direct display of stored water level on RiOs and Elix systems Vent filter for removal of volatile organics, bacteria and CO2 Automatic UV exposure to reduce bacteria levels Eliminate the need for chemical sanitization Water leakage alarm Fits into Millipore PE Reservoir base Delivers pressurized water continuously Vent filters ((TANKMPK02)): Polyethylene vent filters to protect purified water from ingress of
airborne microorganisms Millipore Millipak Express 40 PK/1 filters: 0.22 µm membrane filters designed as a safe and
efficient barrier against particulates and bacteria.
ltrapure Water Quality
Parameter Value
Resistivity 18.2 MΩ.cm @ 25 °C
TOC ≤ 5 ppb (µg/L)
Pyrogens (endotoxins) < 0.001 Eu/mL (pyrogen-free) after BioPak
RNases < 0.01 ng/mL (RNase-free) after BioPak
DNases < 4 pg/mL (DNase-free) after BioPak
Microorganisms < 0.1 cfu/ml after Millipak or BioPak
Particulates > 0.22 µm < 1 particulate / mL after Millipak Express 40
Flow rate Adjustable from trigger: from 50 mL /min up to 2 L/min
* Resistivity can be displayed temperature-compensated at 25 °C or non-temperature-compensated as required by USP
Ultrapure Water delivery
Parameter Value
Manual dispense flow rate Adjustable between 50 and 2000 mL/min
Automatic dispense volume
100 mL, then 250 mL to 5 L by 250 mL increments, then 5 L to 60 L by 1 L increments
Volumetric dispense accuracy
3 % for volumes between 250 mL and 60 L
Volumetric dispense dispersion
CV < 3% for volumes between 250 mL and 60 L
Feed Water Specifications (*)
Parameter Value
Feed Water Quality Potable Tap Water Feed
Feed Water Conductivity < 2000 µS/cm @ 25°C
Feed Water TOC < 2000 ppb
Feed Water Pressure 1 - 6 bar
Feed Water Temperature 5 - 35°C
Feed Water Chlorine < 3 ppm
Feed Water Fouling Index < 12
Feed water pH 4 to 10 pH units
Feed Water Connection 1/2 in Gaz M
(*) If some feed water are out of specifications, solutions exist to make it acceptable for Milli-Q Direct operation – contact Millipore Tech Service for more information
Product Dimensions
Accessories:
Vent Filters for Pure Water Storage Reservoirs (TANKMPK01) Progard T3 Pack for RO cartridge Wall mounting bracket Wall mounting bracket – Tank Water sensor for integral Sanitary tablets Millipore Q-pak TEX
Pure Water Quality
Parameter Value
Ions rejection 97 to 98% with new RO cartridge
Organics Rejection > 99 % for MW > 200 Dalton
Particulates & Bacteria Rejection
> 99%
Pure Water production and delivery
Parameter Value
Production Flow Rate 8 L/hour or 16 L/hour
Delivery Flow rate From tap: up to 2.5 L/min From optional pump: up to 15 L/min at 1 bar
Q-POD Accessory Dimensions
Parameter Value
Q-POD height 579 mm (23.50 in)
Q-POD diameter 230 mm (9.05 in)
Dispenser delivery loop length 800 mm (31.49 in)
Q-POD weight (packaged) 7.2 kg (15.87 lb)
Q-POD weight (empty) 5 kg (11.02 lb)
Q-POD weight (with water) 5.5 kg (12.12 lb)
Loop & cable to system length 290 cm (114.1 in)
Data connection Parallel Port (25-pinD-Sub) for print-out
Incubator shaker
Combined incubated/refrigerated temperatures with orbital shaking in a compact footprint. Designed to minimize bench space and are affordably priced. Ideal for cell culture, solubility studies, extraction procedures, protein expression and many
other applications. Transparent lid Chamber holding atleast four 1L flasks Choose from two temperature ranges: incubated (5°C above ambient to 80°C) Monitor and control chamber temperature range with ±0.1°C accuracy at 37°C Triple eccentric drive handles heavy loads, uniform agitation and continuous 24-hour operation,
even at high speeds Over temperature safety feature with independent thermostat provides additional backup by
controlling heat if main temperature controller fails Interlock stops platform when lid is opened LED displays for speed, time and temperature Variable speed control from 15 to 500rpm Continuous and timed operation from 0.1 hour up to 999 hours or 0.1 to 999 min. Shaker shutdown and audible/visual alarms signal temperature deviations or if unit operates
±10% of set speed, preventing shaker from walking Soft-start feature for sudden starts and stops, splashing of vessel contents or wetting of flask
closure Set point retention retains parameters during power failure and restarts unit automatically after
power is restored Solid-state DC brushless motor is maintenance-free Operating Chiller Provides a refrigerated atmosphere For plasmid purification and protein expression in bacteria for use with MaxQ 4450 with cooling
coil option Achieve temperature ranges from 20° to 30°C
Specifications
Temperature Accuracy ±0.1°C at 37°C
Motor Triple eccentric drive
Chamber Capacity 4 x 1L flasks
Orbit 0.75 in. (1.9cm)
Platform L x W 11 x 13 in. (28 x 33cm)
Platform Load Capacity 35 lb. (15.9kg)
Overall L x W x H 27.2 x 14.1 x 15.8 in. (69.1 x 35.8 x 40.1cm)
Shipping Weight 77 lb. (35kg)
Eppendorf type pipette systems
2.5, 10, 20, 100, 200, 1000 microlitre pipettes Pipette stand One full rack of Pipette tips for each volume of pipettes
pH meter pH/mV/C/F modes Includes meter pH/ATC plastic body refillable electrode liquid-filled, glass body combination pH Ag/AgCl Electrode ATC probe (13-620-19). Operational manual Power supply pH standards LCD display
HPLC
Item LC-2010CHT LC-2010AHT
Quaternary pump
Flow rate setting range 0.001 ~ 5 mL/min (1.0-35.0 MPa/145-5076psi)
Flow rate accuracy ± 1% (1mL/min, 3.0-10.0 MPa/435-1450psi, using water, and fixed ambient temperature of 20°C , except during gradient solvent delivery), ± 2% (except for above conditions) or ± 2μL/min, whichever is greater
LPGE Number of solvents and setting range
Up to 4 solvents 0 to 100%, 0.1% steps
Concentration accuracy
± 0.5% (aqueous acetone/water, binary gradient, flow rate 0.1-2.0mL/min, pressure 1.0-20.0MPa/145-2900psi)
Concentration precision
± 0.1% (aqueous acetone/water, binary gradient, flow rate 0.1-2.0mL/min, pressure 1.0-20.0MPa/145-2900psi)
Sampler Injection method Variable volume (without sample loss)
Injection volume setting range
0.1-100μL (standard), 1- 2000μL in 1μL steps)
Sample capacity
1 ml vials 350
1.5 ml vials 140
4 ml vials 100
MTP 4 96- or 384-well micro titer plates
DWP 4 96-well deep-well plates
Injection repeatability RSD<0.3% (with 10μL injection)
Carry over 0.01% (under naphthalene analysis conditions)
Injection volume accuracy ± 1 % (50μL, n=6)
Injection volume correction
Possible
Sample cooler (LC-2010CHT)
4 to 40°C using Peltier element
Oven Type Block heating/cooling with preheating of the mobile phase
Temperature control precision
± 0.1°C
Temperature control range
(Ambient temperature -15°C) to 60°C
Both UV Detector And RI detector
Light source Deuterium lamp
Wavelength range 190 to 600nm
Bandwidth 8nm
Wavelength accuracy ± 1nm
Wavelength precision ± 0.1nm
Drift 1 x 10-4 AU/h (250nm air cell)
Noise level ± 0.25 x 10-5 AU (for response of 1s, 250nm, air cell)
Cell path length, cell volume
10mm, 8μL (STD flow cell), 5mm, 2.4μL (semimicro flow cell)
2 wavelengths monitoring Any two wavelengths from 190 to 370nm or 371 to 600nm
Controller Display Backlit liquid crystal display (320 x 240 dots), black and white
Input/output terminals 2 x external inputs, 2 x external outputs, 1 x optical link (for chromatopac), 1 x
Operating temperature range 4 to 35°C
Power requirements AC 100V - 240V
Dimensions,Weight Compact and light weight enough to handle by two persons
Computer One dedicated PC to operate (25’’ inches monitor)
Column C18 reverse phase and aminex carbohydrate column
Installing and training needed
Gas chromatography
Gas chromatography start up package, 230 V 60 Hz
Detectors: FID and TCD
Columns: columns for alcohol, organic acid, phenolic analysis etc
Injection unit : Split/Splitless Injector module
Flame Ionization Detector module
Thermal Conductivity Detector module
Approximate Instrument Dimensions and Weight Height: 18-3/8 in. (465 mm) Width: 25-7/8 in. (655 mm) Depth: 20-1/8 in. (511 mm) Weight: 90 pounds (41 kg)
Operating range: 0–55 °C ambient (20–27 °C optimum) 5–95% humidity (50–60% optimum)
Detector Signal For external processing - recorder, integrator, or computer
Power Requirements Voltages: 120/200/220/240 Range: +10%, –10% each Frequency: 47.5–66 Hz Output: 7,500 Btu/hr max
Installing and training : Needed
UV visible spectrophotometer
UV visible spectrophotometer
with and without nano cell
external dimensions: 24’L x 19” W x 11” H
weight: 32 lbs
Electrical requirements: 10 – 240 V, 50 – 60 Hz, selected automatically 150 W maximum
Specifications
Bandwidth Variable: 1nm; 2nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized
Optical Design
Double Beam with sample and reference cuvet positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Light Source
Xenon flash lamp, 3-year warranty (Typical lifetime: 5 years)
Detector Dual Silicon Photodiodes
Wavelength
Range 190 to 1100nm
Accuracy ±0.8nm (full range 190 to 1100nm)
Scanning Speed
<1 to 6000nm/min; variable
Photometric
Range >3.5A
Accuracy 0.5A: ±0.004A 1A: ±0.006A 2A: ±0.010A Measured at 440nm using neutral density filters traceable to NIST™/NPL
UV Accuracy
0.5A: ±0.004A; 1A: ±0.006A; 2A: ±0.010A (Measured at 440nm using neutral density filters traceabel to NIST™/NPL
Noise 0A: ≤0.00015 A 1A: ≤0.00050 A 2A: ≤0.00080 A RMS 260nm, 1nm SBW, RMS
Bioreactor system
Suitable for microbial Culture Working Volumes from 0.4 to 1L Integrated 4-gas mixing system (Air, O2, N2, CO2) Freely selectable gas composition to sparger or overlay (headspace) 4 Flow Meters for individual flow rate setting DO control via automatic valves for Air and O2 pH control via CO2 / Acid and Base Special Impeller Design for low shear stress Suitable for Bacteria, Yeast and Fungi cultivation Working Volumes from 0.4 to 5L Airflow gassing system with oxygen enrichment capability Efficient agitation system for high cell density cultures Automatic DO control for agitation, air and O2 flow or substrate addition Anaerobic culture PC to control and process/ data acquisition Installing and training onsite needed.
Ultrasonic system and accessories .
Applications: Biological cell disruption/homogenization, emulsification, reaction acceleration, dispersion, fine mixing, degassing
Processing of 700mL and less Soft-touch keypad Autotune plus Memory (AT/M) provides fully-automatic tuning and stores frequency at the end
of each cycle Multiple modes of operation continuous, pulsed, timed, and temperature end-point Setup menu in five languages: English, Spanish, Italian, German or French Digital parameter setting with valid paramter range checking Digital timer (9 hours, 59 minutes, 59 seconds) Amplitude is adjustable from 10 to 100% User I/O offers remote start/stop control and teh ability to view temperature, amplitude, and
power values during experiments Automatic end-of-cycle shutoff using limit paramters Self diagnostics on start-up RS-232 port for remote computer access Sound proog enclosure
PCR
Mastercycler® nexus
Thermoblock Aluminum
Sample capacity 96x 0.2 mL PCR tubes or 77x 0.5 mL PCR tubes or 1x
96 well PCR plate
Temperature control range 4-99°C
Temperature control mode Fast, Standard, Safe
Heating technology of the block
Peltier Elements, Triple Circuit Technology
Gradient No
Lid temperature range 37-110°C
Lid Type Flex lid for ergonomic lid opening
Block homogeneity 20-72°C < ±0.3°C, 95°C < ±0.4°C
Block temperature accuracy
≤ ±0.2°C
Heating rate approx. 3°C/s
Cooling rate approx. 2°C/s
Interfaces USB, Ethernet, CAN in/out
Power consumption 700 W
Dimensions (W x D x H) 25 x 41.2 x 32.1 cm
Weight 24 lb / 10.9 kg
Accessories:
Submarine electrophoresis unit
Gel Dimensions (w x l) . . . . . . . . . . . . . . . 15 x 20 cm, 15 x 15 cm, or 15 x 10 cm Maximum Buffer Volume . . . . . . . . . . . . . . 1.2 L Maximum Power Settings . . . . . . . . . . . . . . 200 V, 100 mA, 20 W Maximum Sample Capacity . . . . . . . . . . . . 60 Maximum Temperature . . . . . . . . . . . . . . . 45°C Indoor Use . . . . . . . . . . . . . . . . . . . . . . . . . 4-40°C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . Up to 80% Unit Dimensions (l x h x w) . . . . . . . . . . . . 36 x 14 x 18.2 cm Safety Certifications . . . . . . . . . . . . . . . . . . EN61010-1, UL61010A-1, CSA C22.2 1010.1, CE
Electrophoresis power supply 400 MA 300V 120V
o Versatile, compact FB300 runs up to three gels at once at either constant current or constant voltage
o Stackable, solid, compact power source o Integral timer and auto shutoff prevents fear of losing valuable information
o No-slip feet anchor provides safe operation o Ideal for mini SDS-PAGE, DGGE/CDGE and DNA/RNA submarine electrophoresis
o Maximum voltage: 300V o Maximum current: 400mA o Maximum power: 75w o Three jacks o Internal timer: 0 to 999 minutes
BioDOc imagaing workstation: o Uses your existing computer running capture software on supplied CD o High resolution images with low-light capability
CCD Camera and Capture Software
o Software enables acquisition, camera control, enhancement, annotation and archiving of digital
image; compatible with Windows™ 98SE, ME, XP, 2000 o DigiCam 110 digital color camera, 5.1 megapixel resolution, 4:1 zoom lens; max. Field of View, 29.5
x 22.2cm o Apertures from f/2.8 to f/8.0; automatic or manual focus and exposure; 1/4000 to 16 seconds
exposure times o Focusing ranges: normal, 8 to 31 in. (0.2m to 0.8m); close-up, 1 to 8 in. (0.03m to 0.2m) o UVP filter and diopter included o Resolution settings from 640 x 480 to 2592 x 1944; interpolated print resolution to 3264 x 2448 o High or low image compression with multiple file formats: jpeg, bmp, tif, gif, tga, png o USB interface; operates on Li-Ion battery; with charger and AC power supply o Additional functions available when software is not in use: multi-mode exposure controls, color LCD
monitor, variable shutter speeds, flash controls, Smart Memory Card, utility and photo software and more
o Camera measures 43/8 x 3 x 23/4 in. (109.2 x 76.2 x 68.6mm); weight, 11 oz. (307g)
Darkroom
o Sturdy enclosure provides a darkroom environment and protects the camera o Full-access door; built-in overhead white light o Safety interlock turns UV off when door is open o Viewer window for inspecting gels without opening the door
Analysis software Quickly and automatically detect lanes and bands Designed for use with UVP's basic imaging systems: DigiDoc-It™, MultiDoc-It™ and ChromaDoc-It™;
can also be loaded on a separate computer to analyze gels from BioDoc-It™ systems Image analysis detects straight, curved or slanted lanes and bands automatically or manually and
creates histograms for detailed visual analysis Generates easy-to-interpret quantitative data of lanes and bands Colony Counting function uses wizard commands to set the automatic colony counting of user-defined
areas Enhance images with brightness, contract, gamma, emboss, invert and pseudo color Annotate with text, lines, arrows, ellipse, and highlighter tools—show, hide or burn into image
Save images as various file formats including TIFF, JPEG, BMP and GIF for use in presentations or documentation
Create detailed and user-configured reports Compatible with Windows™ XP (SP2) and newer
UV light converter plate: uv light to white light converter
Plate is specially designed to easily fit on the transilluminator filter surface
UV to white light plates convert to white light for viewing protein gels, coomassie blue stained or silver
stained media
Uniquely phosphored glass assembly (patent pending) converts the UV radiation via a white diffuser
Converts UV to 460-470nm with the Visi-BlueT plate for viewing GFP stains, or to 365nm UV with the
UV/UV plate for preparation and gel excision
Scratch-resistant glass is mounted in a metal housing for durability
Rubber seal stops the plate from sliding
Handles are situated on two sides of the plate for easy handling
Several standard plate sizes are available, custom sizes are also available
UVP mitsubhishi printer thermal digital Document gel images with high-quality, gray-scale thermal prints
Connect printer to UVP's systems easily Compact printer processes low cost prints in seconds
UVP filter emission sybr Green