EquipmentThe information reported here is obtained from
manufacturers and from other sources consideredto be reliable. Science does not assume responsibil-ity for the accuracy of the information. A couponfor use in making inquiries concerning the itemslisted is included in the post card insert.
* CABLE EVALUATOR automatically testsfor leakage and continuity between anyand all wire terminations of a cable har-ness or device. The unit includes twoscanning circuits, a tape reader andcode storage unit, a tape punch, an out-put printer, and leakage- and continuity-detection circuitry. The tape is punchedto record continuity found in the test ofa reference sample device. Tape pro-duced in this way is used to programthe device for comparison tests of otherequipment. (James Cunningham Sonand Co., Inc., Dept. 409)
* X-RAY FLUORESCENCE SPECTROMETER
permits simultaneous analysis of up to22 elements in the wavelength range0.35 to 10.2 A. A ratio-recording systemprovides inked records showing the con-centrations of the elements analyzed.(Applied Research Laboratories, Inc.,Dept. 406)
* CRYSTAL OVEN employs a mercurythermoswitch to provide temperaturecontrol. Oven temperature is maintained±0.010C at fixed ambient and ±0.1'Cover an ambient range of 00 to 50"C.The unit operates on 24 v d-c or 6.3 va-c. Pressurized inert gas above the mer-cury column prevents mercury separa-tion under shock and vibration. Theoven accommodates an HC-6/U crystalholder. (Manson Laboratories Inc.,Dept. 410)
* STREAK CAMERA produces a plot ofspace in one direction versus time in anorthogonal direction of self-luminousevents. Standard 35-mm film is used.The image is swept onto the film by atriangular mirror rotated by a high-speedturbine. The fastest drive available rangesfrom 200 to 5500 rev/sec. Maximumwriting rate is approximately 8 mm/gsec. Control equipment includes a fre-quency counter for measurement ofmirror speed, mirror speed adjustments,and controls for the capping shutter andthe explosive-actuated blast shutter usedto prevent double exposure. (Beckmanand Whitley, Inc., Dept. 411)
* NUCLEAR-COUNTER SIMULATOR for use
in developing and testing radiationcounting instruments provides recur-rent, exponentially shaped voltage pulsessimulating the output of a gas-fillednuclear-particle counter tube. Pulse rateis adjustable from 1 to 15 per secondand voltage from 0 to 100 mv. (Auto-mation Dynamics Corp., Dept. 414)24 OCTOBER 1958
* VECTOR BRIDGE provides direct indica-tion of magnitude and phase-angle com-ponents of impedance from 60 cy/secto low radio frequency. Phase range is± 90 deg; impedance range is to 100,000ohm. Accuracy is better than ± 1 degfor phase angle and ± 1 percent for im-pedance. An accessory plotting devicepermits recording of points on rectangu-lar coordinate paper. (Harris Trans-ducer Corp., Dept. 419)
* LEAK DETECTOR of the helium mass-spectrometer type achieves fivefold in-crease of sensitivity over previous modelsby introduction of a butterfly valve be-
ELECTRONIC
Thermometer* Rapid, Accurate, Direct Reading* Low Cost, Portable, Thermistor Type* Many Ranges from - 35 to + 1000 C.* Interchangeable & Special Probes* Controllers & Recorders Available
COMPACT
Magnetic Stirrer* Stir at Any Angle* In Open or Closed Vessels* Under Vacuum or Pressure* With or without Hotplate
TEFLON
Tissue Homogenizers* Interchangeable Teflon Pestles* Precision Bore Pyrex Glass Tubes* Notched for Quick Change Chuck* Complete Apparatus Available
AUTOMATIC
Egg-Punch* For Opening Embryonated Eggs* Open 60 Eggs Per Minute* Clean, 1" Circular Fracture* One Hand Efficient Operation
tween the manifold and the diffusionpump. A leak rate of 2 x 10-1' atmoscm3/sec of helium will produce 5 per-cent of full reading. (Consolidated Elec-trodynamics Corp., Dept. 424)
* AMINO ACID ANALYZER combines ion-exchange chromatography with auto-matic colorimetry to perform quantita-tive analysis of mixtures of amino acids.The sample to be analyzed is passedthrough a variety of columns, and theeffluent stream is combined with a regu-lated flow of ninhydrin reagent. Theresulting mixture flows into a heated re-action vessel and thence into a photom-
Write for specifications and details to Dept. S
1011
on May 5, 2018
http://science.sciencem
ag.org/D
ownloaded from
eter assembly. The latter measures ab-sorption at 440 and 570 mvt and performsa third absorption measurement with a
shortened light path to provide a widerange of sensitivities. Three separate ab-sorbance curves are printed in multi-color dots by a recorder. (Phoenix Pre-cision Instrument Co., Dept. 428)
* SCINTILLATION SCANNFR maps sites ofradioactive material in human bodies.Whole-body scanning is fully automaticand is recorded in scale of 1:4. Full-scale scanning can be performed of areas
560 by 420 mm. A wide variety of spac-
ings, scanning speeds, and scaling fac-tors is offered. (LKB Produktor Fab-riksaktiebolag, Dept. 415)
* PERFORATED-TAPE READER operates at
1000 characters per second. Reading isphotoelectric. Stopping time is slightlymore than 1 msec. The next characteris read with 5 msec of reinitiation of theread operation. The reel will hold 350or 700 ft of tape. Automatic rewind andend-of-tape sensing are provided. (Bur-roughs Corp., Dept. 430)
1012
* TENSILE TESTER consists of separateloading and recording sections for re-mote testing. Deformation rate is con-stant and continuously adjustable from4 to 4000 in./min. The instrument pro-duces a photographic record calibratedin terms of stress, strain, and time. Alle-gany Instrument Co., Inc., Dept. 416)
* TESTING MACHINE provides automaticsimulation of a wide range of stress andstrain at elevated temperatures. Capacityis zero to 50,000 lb. Temperature rangeextends beyond 3000'F. Ram rates upto ¾4 in./sec, temperature rises to 200'Fper second, and cycling rates of 10 persecond are possible. Variable-reluctancetransducers sense strain and load. Meas-urements are automatically recorded on,an 8'/2- by 11-in. graph. (MarquardtAircraft Co., Dept. 417)
* SOLID-STATE BATTERY has a potential of95v in 0.14 in3. It can supply 10-3 pafor 176,000 hr or a flash current of 20pta. Voltage per cell is 0.8, and configur-ations providing 95 v/in. and 625 v/in.3can be produced. Steady current persquare inch of cell area ranges from10-5 amp for 100 hr to 10-8 amp for anestimated period of 100,000 hr for a 10-percent voltage drop. Flash current of200 ,ua/in.2 is obtainable. Temperaturecoefficient is 1.2 x 10-3 v/deg v between-50° and + 50'C. (Universal WindingCo., Dept. 418)
* FRACTIONATION COMPUTER accepts elec-trical input signals from instrumenttransmitters installed in the fractionationprocess loop and performs computationdesigned to maintain product quality.Calculations are based on feed flow rateand product analysis. (Southwestern In-dustrial Electronics Co., Dept. 422)
* AIRBORNE-PARTICLE SAMPLER iS builtaround a turbine-type blower and has acapacity of 75 ft3/min. Flow is measuredby a self-contained variable-orifice meter.A variety of filters is available. (Nu-cleonic Corp. of America, Dept. 425)
* TEMPERATURE RECORDER has sensitivityand accuracy ±0.001°C on a full scaleof 0.5°C. The instrument combines athermistor sensing element and a strip-chart recorder. Any 0.50C portion of thetotal range 20° to 30CC may be selectedby a switch. Other ranges and multi-point measurement can be furnished.(Fenwal Electronics, Inc., Dept. 426)
* COOLING COIL is a refrigerated coil thatcan be immersed in liquid or placed ina cabinet as needed. A rolling cabinethouses the compressor and thermostat.A 5-foot, flexible extension hose couplesthe tinned-copper cooling coil, measur-ing 8 in. by 4'/2 in. in diameter, to thecabinet. Temperature control is main-
SCIENCE, VOL. 128
on May 5, 2018
http://science.sciencem
ag.org/D
ownloaded from
CONTINUOUS CO2 ANALYZER
A simple CO2 Analyzer based on thecritical orifice principle.*
Specifications
Sample flow rate-100 cc./min.
Range-0 to approx. 10% C02Accuracy ± 0.05% CO2
Response time-2 to 3 min. forfinal reading
Vacuum requirement-simple wa-ter aspirator which reduces pres-sure to at least half atmospheric
Chemicals-Ascarite, Drierite andgauge oil supplied
The analyser is particularly suitedfor continuous analysis of both ex-pired gas and alveolar gas (e.g. asprovided by Rahn end-tidal sampler)in student physiology laboratories.The sampling rate is such that theunit can be used in series with aPauling oxygen analyzer.
*J. Mead. A critical orifice CO2analyzer suitable for student use.SCIENCE, Vol. 121, Pages 103-4,1955.
CO2 Analyzer, complete-$145.00F.O.B. Dover, Mass.
HARVARD APPARATUS CO.,INCORPORATED
Dover, Massachusetts, U.S.A.
(A nonprofit organization)
tained ± 20F from ambient to 50F. Atemperature probe inserted with the cool-ing coil controls the thermostat. Opera-tion is on 115 v a-c. (Andrew TechnicalSupply Co., Dept. 429)
* INDICATOR TUBE of numeral-electrodeneon-glow type is available with di-ameter of 3 in. Digital indication of thetube is said to be readable at distancesgreater than 150 ft. (Burroughs Corp.,Dept. 427)
* SHAFT-ANGLE DIGITIZER solves the prob-lem of centering of the measuring diskby taking the arithmetic average of twodial readings at diametrically oppositepoints. Readings are made by two photo-diodes counting two waveforms in-scribed on the disk. By counting the num-ber of crossings of the two waveforms,digital logic may be applied to followbidirectional rotation. (Dynamics Re-search Corp., Dept. 420)
* FREQUENCY-SELECTIVE VOLTMETER COV-ers the frequency range 1 to 400 kcy/sec.The instrument uses the heterodyne prin-ciple and crystal-filter selectivity. A 100-cy/sec-bandwidth filter and a 3-kcy/sec-bandwidth filter are provided. A direct-reading meter is calibrated from - 90 to+ 32 dbm with accuracy ± 0.5 db overthe instrument range. (Railway Commu-nications, Inc., Dept. 423)
* SCINTILLATION SPECTROMETER is an au-tomatic instrument that utilizes a stepdrive to advance the base line sequen-tially, 1 volt at a time, for up to 100channels. Counting time for each settingmay be from 0.5 to 8 min. Counts are ac-cumulated, and the total is recorded atthe end of the chosen period. Count in-tegration for the next channel starts assoon as the previous value has been resetto zero. (Baird-Atomic Inc., Dept. 431)
* CHLORIDE TITRATOR operates by react-ing chloride ions with electrochemicallyproduced silver ions. A constant directcurrent between a pair of silver elec-trodes provides silver ions until all chlo-ride has been reacted. At this point un-reacted silver ions cause an abrupt in-crease in conductivity, actuating a relayto interrupt the current and stop a timer.Elapsed time is proportional to chloridecontent. Titration time usually rangesfrom 5 to 60 sec. (American InstrumentCo., Inc., Dept. 432)
* POTENTIOSTAT maintains the potentialbetween an electrolyte and a test sampleconstant by monitoring the potentialwith a standard electrode. Potential isadjustable between 0 and + 2 v, and cur-rent is variable ±50 ma. (Shandon Sci-entific Co., Ltd., Dept. 449)
JOSHUA STERNNational Bureau of Standards
24 OCTOBER 1958
for work in acontrolledatmosphere
BLICKMANVACUUM DRY BOX
Designed for safe handling ofradio-isotopes, reactor fuel con-taining Plutonium or U233 andother hazardous substances. Withair-lock, it can be sealed to createa vacuum. Fabricated of stainlesssteel plate-34" long x 26" high x24" wide at base. Air-lock meas-ures 18" x 12". Send for Techni-cal Bulletin A-2.
FOR SAFE HANDLING OFRADIOACTIVE MATERIALS
BLECKMAN FUME HOODOriginally designed and (level-oped for the AEC. this FumeHood assures maximum safety inthe handling of radioactive ma-terials and radioactive isotopes.Sturdy 14-gauge stainless steel,round corner construction pro-vides long life ... easy cleaning anddecontamination. Send for Tech-nical Bulletin E-3. S. Blickman,Inc., 0910 Gregory Avenue. \Vee-hawken, N. J.
BLICKMANLABORATORY EQUIPMENT
Look for this symbol of quality
1013
Ion M
ay 5, 2018
http://science.sciencemag.org/
Dow
nloaded from
EquipmentJOSHUA STERN
DOI: 10.1126/science.128.3330.1011 (3330), 1011-1013.128Science
ARTICLE TOOLS http://science.sciencemag.org/content/128/3330/1011.citation
PERMISSIONS http://www.sciencemag.org/help/reprints-and-permissions
Terms of ServiceUse of this article is subject to the
is a registered trademark of AAAS.Sciencelicensee American Association for the Advancement of Science. No claim to original U.S. Government Works. The title of Science, 1200 New York Avenue NW, Washington, DC 20005. 2017 © The Authors, some rights reserved; exclusive
(print ISSN 0036-8075; online ISSN 1095-9203) is published by the American Association for the AdvancementScience
on May 5, 2018
http://science.sciencem
ag.org/D
ownloaded from