  • 8/8/2019 Enggo Technical Spec Final

    1/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    1

    PORTABLE OXYGEN DETECTOR

    The SP1217 is a portable oxygen gas detector which has

    been designed to protect the safety of workers in

    dangerous work places. It operates for one half year and

    more without replacing the battery or sensor. It isextremely small lightweight, and is low priced. The small

    size and light weight make the SP1217 ideal for personal

    use. If the concentration of gas reaches a dangerous level,

    the SP1217 automatically makes vibration as well as visual

    and audible alarms. For the convenience of the users, a

    high-quality microprocessor is installed and contains

    automatic zero-calibration function, and one-touch span-

    calibration function. The loud audible alarm, vibration alarm and high-brightness Backlight are

    easily recognized. SP1217 displays the maximum and minimum oxygen concentration on demand,

    and it has the function of current time setting.

    Model: SP1217

    Specification

    - Detecting gas : Oxygen(O2)

    - Sensor type : Electrochemical (Galvanic type)

    - Sampling Method : Diffusion

    - Response Time : T90 in 10 seconds

    - Power : 3.0V Coin Battery (CR2450)

    - Alarm indicators : Clearly advises alarm levels both audibly and visually

    - Audible alarm : High output Buzzer (80dB at 10cm)

    - Visual alarms : Flashing back light visible from all angles

    - Vibrator alarm : Pulses warning in gas alarm conditions and status alarms- Alarm point : Low(1st) alarm 19.5%, high(2nd) alarm 23.5% (user changeable)

    - Other alarms : Low battery and sensor fail alarm

    - Calibration : Zero calibration (0% O2), span calibration (20.9% O2)

    - LCD Display : Concentration, current time, battery status and alarm level encountered

    - Backlight : Alarm conditions (auto) and on demand

    - Field option : Set real-time clock

    - Operating temperature : -20 ~ +50

    - Humidity : 15% ~ 90% RH (non-condensing)

    - Size : 48.5mm(W)84mm(H)32.5mm(D)

    - Case : High-impact Plastic, Dust Proof and Weather Resistant

    - Warranty : Full 12 months warranty

    Applications

    Petrochemical, Power Plant, Telecom, Medicine, Mine, Heavy industry, Army, Food industry, Gas

    industry, and other confined spaces for worker safety

  • 8/8/2019 Enggo Technical Spec Final

    2/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    2

    PORTABLE TOXIC GAS DETECTOR (SP SERIES)

    CO H2S

    H2

    SO2

    The SP series is a portable toxic gas (CO, H2S, SO

    2, H

    2etc) detector which has been designed to

    protect the safety of workers in dangerous work places. It operates for two years without replacing

    the battery or sensor. It is extremely small lightweight, and is low priced. The small size and light

    weight make the SP series an ideal for personal use. If the concentration of gas reaches a dangerous

    level, the SP series automatically makes vibration as well as visual and audible alarms. The SP series

    also monitors STEL(Short Term Exposure Limit) and TWA(Time Weighted Average) plus instant gas

    alarms. The loud audible alarm, vibration alarm and high-brightness Backlight are easily recognized.

    Model Gas Range 1st 2nd TWA STEL

    SP1227 CO 0-500ppm 25ppm 50ppm 25ppm 200ppm

    SP1257 SO2 0-20ppm 2ppm 4ppm 2ppm 5ppm

    SP1277 H2 0-1000ppm 100ppm 500ppm N/A N/A

    SP1297 H2

    S 0-100ppm 10ppm 30ppm 10ppm 15ppm

  • 8/8/2019 Enggo Technical Spec Final

    3/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    3

    PORTABLE TOXIC GAS DETECTOR (SP SERIES) continue

    Specification

    - Detecting gas : CO, H2S, SO2, H2 etc

    - Sensor type : Electrochemical- Sampling Method : Diffusion

    - Response Time : T90 in 10 seconds(SP1227), in 75 seconds(SP1257), in 90 seconds(SP1277), in 30

    seconds(SP1297)

    - Power : 3.0V Coin Battery (CR2450)

    - Alarm indicators : Clearly advises alarm levels both audibly and visually

    - Audible alarm : High output Buzzer (80dB at 10cm)

    - Visual alarms : Flashing back light visible from all angles

    - Vibrator alarm : Pulses warning in gas alarm conditions and status alarms

    - Other alarms : Low battery and sensor fail alarm

    - Calibration : Zero calibration, span calibration (20.9% O2)- LCD Display : Concentration, current time, battery status and alarm level encountered

    - Backlight : Alarm conditions (auto) and on demand

    - Field option : Set real-time clock

    - Operating temperature : -20 ~ +50 - Humidity : 15% ~ 90% RH (non-condensing)

    - Size : 48.5mm(W)84mm(H)32.5mm(D)

    - Case : High-impact Plastic, Dust Proof and Weather Resistant

    - Warranty : Full 12 months warranty

    Application

    Petrochemical, Power Plant, Telecom, Medicine, Mine, Heavy industry, Army, Food industry, Gas

    industry, and other dangerous places sometimes exposed to a toxic gas leak for worker safety

  • 8/8/2019 Enggo Technical Spec Final

    4/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    4

    PORTABLE 4 GAS DETECTOR

    Model: SP12C7The Portable 4 gas detector (SP12C7) is a multi-gas detector designed to provide reliable personal

    safety. The SP12C7 is available with up to four independent gas sensors for the protection. The

    SP12C7 measures typically oxygen, combustibles, and 2-toxic gases among CO, H2S, SO2, NO2, Cl2,

    H2, HCN, and NH3. It features an extra large liquid crystal display (LCD) and an optional sample pump

    that is built right into the instrument, yet it's small enough to carry in your hand or clip to your belt.

    Specification

    - Sensor type : 1ea-Catalytic combustion, 3ea-electrochemical

    - Detecting gas : Combustibles, O2,(mandatory) CO, H2S, SO2, NO2, Cl2, H2, HCN, NH3 (two gas

    selection)

    - Display : Big size 128 X 64 graphic LCD

    - Alarm : High brightness LED, Buzzer (110dB at 30cm)

    - Power : Rechargeable battery

    - Additional function : Data logging

    Application

    Refineries, chemical processing, water & waste water facilities, semiconductor manufacturing, rail car

    and tank truck cleaning, resin and nylon production, underground storage, sewer entries, cable

    vaults, agriculture, etc.

  • 8/8/2019 Enggo Technical Spec Final

    5/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    5

    GAS LEAK ALARM SYSTEM (LPG/LNG)

    LPG/LNG Gas Detector

    Model: SI560LPG

    Flammable gas detector(SI560LPG) is a separated gas detector, composed of detection part and control

    part which displays gas concentration from the signal received from the detection part. Detection part

    has a structure of flameproof enclosures. In order to stabilize the sensor operation, we introduced a

    stabilization step at an initial stage of operation. SI560LPG is also robust for the change of surroundingtemperature and input voltage and designed to consume the minimum electric power. Automatic shut-

    off gas valve is operated by transmitting a gas leakage signal to automatic shut-off gas valve

    Specification

    - Detecting gas : LPG/LNG gas

    - Sensors : Catalytic combustion type, Diffusion type

    - Detector type : Single detector type (separated with detection part and control part)

    - Power : AC 220V, 60Hz

    - Power consumption: 9W @Max

    - Alarm point : 20% LEL

    - Alarm : Yellow LED lighting and buzzer sound

    - Power indication : Green LED lighting

    - Breakdown indication : Red LED lighting

    - Output voltage : DC 12V.

    - Relay contact : COM. NO. NC (250V,3A)

    - Operating temperature : -20 ~ 50 - Operating humidity : 0 ~ 95%RH.

    - Dimensions : 140mm(W)200mm(D)78mm(H) (control part)

    130mm(W)107mm(D)73mm(H) (detecting part)

    - Weight : 1.5 Kg- Connection wire: VCTF 3C0.75mm2, 3m

    - WARRANTY: Full 12 months warranty

    Application

    Boiler room, plant, gas storage, gas facilities, restaurant, building, condominium, laboratory.

  • 8/8/2019 Enggo Technical Spec Final

    6/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    6

    GAS DETECTION SYSTEM FOR HOME SAFETY (SH1362)

    Model: SH1362

    Gas monitoring system has a gas alarm, controller and shutoff Device. If the gas is leaked from the

    gas valve or gas pipe, the gas detector detects gas leaks and sends the signal to the controller. The

    controller exams the signal and then send to the shutoff device. Shutoff device operated to close the

    gas pipe to prevent the gas explosion.

    SH1362SENSORModel Name MR-100Power DC12V 20%

    Detectable gas LPG, LNG

    Alarm indication Flashing yellow LED with audible alarm

    Alarm concentrationLPG(600ppm ~ 4,500ppm)

    LNG(600ppm ~ 12,500ppm)

    Power consumption 1.3W

    Alarm output DC8V ~ 12V

    Operating temp -20C ~ 50C / 0% ~ 95%RH

    Dimension 85mm 75 mm 30mm

    Weight Approx 80g

  • 8/8/2019 Enggo Technical Spec Final

    7/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    7

    GAS DETECTION SYSTEM FOR HOME SAFETY (SH1362) continue

    SH1362CCONTROLLER Power AC 220V, 50/60Hz

    Shut-off system Electric motor

    Shut-off time Within 30 seconds

    Indication of open /

    close

    Open lamp (green)

    Close lamp (yellow)

    Indication of

    Gas leak

    Flashing close LED

    with audible alarm

    Operation Remote / Manual

    Dimension 75 105 45 mm

    Weight Approx 350g

    SH1362SSHUT-OFF VALVEPower DC 12V

    Operation Automatic / Manual

    Dimension 60 130 150 mm

    Weight Approx 350g

  • 8/8/2019 Enggo Technical Spec Final

    8/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    8

    FIXED GAS DETECTOR FOR INDUSTRIAL SAFETY

    Fixed gas detector

    Model: SI-100

    The SI series is a state-of-the-art fixed gas detector that canoperate as an independent, stand-alone system or as part of a

    system connected with a wire (RS485 or 4 to 20mA) and wireless

    (RF). The SI series is an explosion proof gas detector for

    continuous monitoring of toxic gases and oxygen in ambient air.

    It utilizes a magnetic wand technique for performing non-intrusive

    calibration.

    SpecificationITEMS SPECIFICATION

    1 Measuring Type Diffusion

    2 Measuring Value Display Local Digital LCD Display

    3 Means Value Display Back light, Custom LCD

    4 Detectible Gas Combustible Gas, Toxic Gas, Oxygen

    5 Measuring Range 0 -100% LEL &0 -100% Volume

    6 Response Time 90% of full scale in less than 20 sec

    7 Accuracy 3% / Full scale

    8 Zero Drift Less than 2% full scale

    9 Operating Temp. -20 to 50 10 Operating Humidity 10 to 95% RH (Non-condensing)

    11 Relays (option) Two alarm Relays(

  • 8/8/2019 Enggo Technical Spec Final

    9/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    9

    WIRELESS GAS DETECTOR (SL-101)

    Gas detector based on Ubiquitous Sensor Network

    Model: SL-101

    Workers in hazardous environments such as confined space, mine, gas leak(explosion & toxic) are constantly exposed to the health and safety hazards

    of dynamic and unpredictable conditions. One approach to enable them to

    manage these hazards is to provide them with situational awareness: real-

    time data (environmental and physical location data etc.) obtained from

    wireless, smart sensor technologies deployed at the work area. SL-101 can

    be rapidly deployed and re-deployed in situation that requires a quick and

    adaptable response. The durable aluminum enclosure is explosion proof

    and can withstand the tough environment of the drilling rig operation.

    Specification

    ITEMS SPECIFICATION

    1 Measuring type Diffusion

    2Measuring value

    displayLocal Digital LCD Display

    3 Detecting gasOxygen(O2), Combustible Gas(CH4,C3H8), Toxic Gas(CO, H2S, SO2, H2,

    NH3 etc.),

    4 Measuring range

    Gas Range Resolution

    Oxygen 0 ~ 40% 0.1%

    Combustible 0 ~ 100% LEL 1% LEL

    Carbon Monoxide 0 ~ 500 ppm 1 ppm

    Hydrogen Sulfide 0 ~ 100 ppm 1 ppm

    Sulfur Dioxide 0 ~ 20.0 ppm 0.1 ppm

    Hydrogen 0 ~ 1000 ppm 1 ppm

    Ammonia 0 ~ 100 ppm 1 ppm

    Chlorine dioxide 0 ~ 1 ppm 0.02 ppm

    Hydrogen Chloride 0 ~ 30 ppm 0.7 ppm

    Hydrogen Cyanide 0 ~ 30 ppm 0.2 ppm

    5 Response Time 90% of full scale in less than 20 sec

  • 8/8/2019 Enggo Technical Spec Final

    10/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    10

    WIRELESS GAS DETECTOR (SL-101) continue

    6 Zero Drif Less than 2% full scale

    7Operating

    Temperature-20 to 50

    8Operating

    Humidity10 to 95% RH (Non-condensing)

    9 Calibration Magnetic interface to configure Alarm

    10 Battery lifetime More than 1year (oxygen, toxic)

    11 Frequency 433MHz, 914MHz, 2.45GHz (depend on customer request)

    12

    Node to Node

    Communication

    Distance

    Maximum 300m (depend on the circumstance to install)

    13

    Number of

    Maximum Node /

    Gateway

    Maximum 500 Nodes per 1 Gateway

    14 Power AA battery 3V (oxygen, toxic), 12V (combustible)

  • 8/8/2019 Enggo Technical Spec Final

    11/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    11

    GAS SENSOR MODULE FOR INDOOR AIR MONITORING

    Gas Sensor Module for Indoor Air Monitoring

    There is gas sensor modules (CO2, smell, TVOC) for indoor air

    monitoring which is applied to apartments, office, house,building. In general, these sensor modules monitor and transfer

    the detecting data to home control system. These also can be

    used solely as a gas detecting module for each gas

    CO2 sensor module

    Specification

    - Detecting gas : CO2

    - Sensor type : NDIR type

    - Detecting range : 0 ~ 2000ppm CO2

    - Accuracy : 3% of reading

    - Repeatability : < 1% over FS

    - Power : DC 5V

    - Power consumption : Peak 240mA, Average 150mA, Low

    120mA

    - Lifetime : 15 years typical

    - Operating temperature : 0 ~ 50 - Operating humidity : 0~95%RH non-condensing

    - Communication method : RS 485, PLC

    ApplicationVentilation control, Air quality monitors, CO2 monitor in green house, CO2 detector etc.

    TVOC sensor module

    Specification

    - Detecting gas : TVOC, Odorous gases such as ammonia and H2S,

    - volatile organic compounds (VOC), hydro carbons (HC) and

    ethanol

    - Sensor type : Metal oxide semiconductor

    - Power : DC 5V

    - Power consumption : 160mA

    - Lifetime : 10 years typical

    - Operating temperature : -20 ~ 100 - Operating humidity : 0~95%RH non-condensing

    - Communication method : RS 485, PLC

    Application

    Air cleaners, Ventilation control, Air quality monitors, VOC monitors, Odor monitors, etc.

  • 8/8/2019 Enggo Technical Spec Final

    12/12

    Copyright Reserved

    Enggo Corporation Sdn Bhd(822201-P)[Tel: +603-78772177] [Fax: +603-7877 2077]Ema il: enquiry@engg o.c om.m y Web site: www.eng go.c om .my

    12

    BREATH CO MONITOR

    Model: BMC2000

    Breath CO Monitor provides the concentration of %COHb in blood

    by monitoring the CO gas of breath. User can monitor a digital

    readout of CO ppm and blood %COHb simultaneously on LCD

    display together with LEDs and audible indicator. CO monitors are

    used by health professionals working in smoking cessation

    programmes. Breath CO Monitor helps the smoker to quit by

    providing clear evidence of impair CO levels and it can be the

    guidelines of progress during the smoking cessation.

    Specification

    - Displays CO ppm and blood %COHb simultaneously- Audible tone and traffic light LEDs provide additional status

    - Countdown timer for hold breathing and auto-zero calibration

    - User can operate and calibrate easily

    - Uses low-priced disposable mouthpieces

    - Can also be used for the monitoring of CO toxic effect and smoke inspiration