Page 1: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Enea Detectors Range

Page 2: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

ENEAis a range of analog addressable detectors and ancillaries for hi end applications

ED100 – SMOKE DETECTORED200 – HEAT DETECTORED300 – COMBINED SMOKE AND HEAT DETECTOR

Page 3: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Designed and manufactured at Inim electronics, it is a 100% italian product

Page 4: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Each device of the new ranges has been approved by LPCB which is one of the most prestigious notification body in fire detection

EN54-5 : Heat Detectors

EN54-7 : Smoke Detectors

EN54-17 : Short Circuit Isolator

EN54-18 : Input/Output devices

Page 5: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

KEY FEATURES

Optical Smoke detectors are based on th eprinciple of the light scattering, to avoid false alarm it is important to avoid contaminations in the analysis chamber

Page 6: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Top side completely sealed to avoid dust or water condensation to reach the chamber

One of the most common false alarm or fault reason is the dust coming from the pipes or condensating water dropping from the top side

Page 7: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Metal mash agains insect wit less than 500um holes diameter

One of the biggest problems of optical smoke detectors is dust or insect entering in the chamber

Page 8: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Electronic circuit completely WAX coated to avoid any contamination

Moisture or environmental pollution may affect the behaviour of hi sensitive electronics circuits in the detector

Page 9: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Sensitive part of the circuit completely shielded by a metal cage

Electromagnetic noise may affect the measurement of the hi gain amplifier generating false alarms

Page 10: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Last generation CPU inside each detector whith hi false alarm rejection algorithm

The measurement of the smoke chamber and thermal probe are evaluated by the internal CPU and by means of the algorithm designed from the Inim R&D department an hi rejection to false alarm is achieved

Page 11: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Smoke chamber easy to open for clean up operations

In case of detector’s chamber contamination detector can be easily opened and cleaned with some air or a soft brush

Page 12: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Each Detector is Full tested with automatic test equipment which measure each single component and verify each electrical connection

Page 13: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Each Detector is Calibrated with a two stage process : one in free air and another one in a smoke tunnel to ensure the same response from each sample

Page 14: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Each Detector is subjected to a «Burn IN test» of 24 hours: the 80% of electronic components failure occur during the first 24 hours of theyr life, detectors live theyr first 24 hours in our burn in test!

Page 15: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Universal mounting base for every detector model

Clip for line continuity restore in case of detector removal

Page 16: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Relay base available direct driving of any type of external device

Page 17: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Each device is identifyed by a serial number

The serial number is reported on the back label and on two small detachable labels : this allow to stick a serial number to map and a serial number to mounting base

Page 18: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Thanks to LOOPMAP technology, which is the ultimate technology in loop addressing and fault finding, no any address operation is required

Page 19: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

After the loop has been wired up, by using the panel and its configuration software or using the EDRV1000 driver with the included FireGenius software…

Page 20: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

The loop wiring is automatically detected and a graphic report (including any T junction etc) is available:

Page 21: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Diagnostic features using Smartleague configuration software:

Page 22: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

Contamination analysis using Smartleague configuration software:

Page 23: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

The interactive graph show where there is a short circuit (each device include a short circuit isolator)

If some divice is not responding

Allow to Manually activate the 3 colour leds, the outputs etc. in order to test the loop

Right button mouse click

Page 24: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

Introducing new devices

For each detector Smoke and heat sensitivity can be adjusted and are available early warning threshold for Smoke and heat level

Page 25: Enea Detectors Range. Introducing new devices ENEAis a range of analog addressable detectors and ancillaries for hi end applications ED100 – SMOKE DETECTOR

THANK YOU