encore presentation sept 2007

50
Click For Animation

Upload: steve-johnson

Post on 24-May-2015

405 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Encore Presentation Sept 2007

Click For Animation

Page 2: Encore Presentation Sept 2007

Product Summary – What is it?• Revolutionary, next generation product family from Dranetz-

BMI for the permanently (and semi-permanent) installed market

• Includes all components and functionality of Signature System.

• Encore Series Model 61000New!

• All new instrument design that builds upon the strengths of prior Dranetz-BMI products:

• Signature System• Strong PQ capabilities• Web browser based interface

• 4400/PX5• Power Quality compliance capabilities• Visualization – Bright, colorful, easy to use local user interface

• Measuring Pad• Physical measurements

Encore Series

Page 3: Encore Presentation Sept 2007

AGDER ENERGI NETT AS – NorwayAllegheny PowerAlliant EnergyAmerican Electric PowerBKK NETT AS – NorwayBonneville ElectricCentral Electric CompanyCentral Networks – UKCentral Service Power of San AntonioCity of Danville, VACity of LakelandCity of Palo AltoCity of TucsonCITY UTILITIES OF SPRINGFIELDCMS EnergyCommonwealth EdisonCompanhia de Electriciadade, MacauConsolidated EdisonDayton Power & LightDuke EnergyELECTROBISTAND - NorwayElektro Primorska, SloveniaELES - Elektrogospodarstvo Slovenije EntergyEPRI-PEACHALOGALAND KRAFT AS - NorwayHawaii ElectricHELGELANDSKRAFT AS - NorwayHEP Transmission Company, CroatiaHEP Distribution Company, CroatiaHYDRO ALUMINIUM – NorwayISTAD NETT ASGuangdong EPRI, ChinaJiangSu EPRI, ChinaKansas City Board of Public UtilitiesKeyspanKnoxville Utility BoardKOREA INSTITUTE OF ENERGY RESLYSE NETT AS

Electric Utilities Government

Aberdeen Proving GroundArgonne National LaboratoriesArup LaboratoriesFederal Aviation AdministrationGovernment communications Headquarters, UKInternal Revenue ServiceInternational Broadcasting BureauLockheed MartinLondon Air Traffic Control, UKMI-5 - UKNASA AmesNational Institute of StandardsNational Renewable Energy Laboratory North Wales Police, UKOnizuka Air Force BaseRaytheonUS Air Force/Lockheed MartinUS ArmyUS NavyThe World BankMcCarran International Airport

Encore Series CustomersMaui ElectricMid American EnergyMorristown Power SystemNational Grid, UKNebraska Public Power

NORDMORE ENERGIVERK AS – NorwayNortheast Utilities

NOTODDEN ENERGY AS - NorwayNew York State Electric and GasOklahoma Gas & ElectricOmaha Public Power DeptPennsylvania Power And Light Electric Utilities CorpPolskie Sieci Elektroenergetyczne SA, PolandPublic Service of OklahomaReliant Energy

ROYOY-LUROY KRAFTVERKAS - NorwaySan Diego Gas & ElectricShanghai Municipal Electric Power Company, ChinaSFE NETT ASShanghai Metro Traffic Co, ChinaShanxi EPRI, China

SINTEF –Norway

SKAGRAK NETT AS – NorwaySouthern California EdisonSunnfjord Energi A/S/ Norway

STATNETT – NorwaySWECO GRONER AS – Norway

TAFJOR KRAFTNETT AS - NorwayTexas UtilitiesTennessee Valley Authority

TUSSA NETT AS - NorwayUnited IlluminatingUnity Electric Corporation

Original Equipment Manufacturers/Partners

BAE SystemsBeacon Power CorporationSocomec - FranceFuel Cell EnergySoft Switching Technologies

PillerToshibaS&C ElectricUTC Fuel Cells

PON CAT AB(Caterpillar) - Sweden

Page 4: Encore Presentation Sept 2007

Alliance & Leicester Bank, UKAmerican ExpressAmSouth BankBank of America, UKBanco de PeruBanco PopularBear StearnsBloomberg, UKChicago Stock ExchangeCiticorpCredit Suisse, UKDeutsche Bank

ABC NetworkAK SteelAkzo NobelAmerican Physical SocietyAsltom BoeingCalvin CollegeCBS NetworksCHARLES SCHWAB & COMPANY INCCPIDade BehringDelta AirlinesDHL AirwaysDiscovery CommunicationsDupont Dyna ElectricElectrical Systems IntlEli LillyElgar SorensonEmerson, ChinaEpsilonFresh DirectGeorgia PacificGolden Era Prod.Hamilton SundstrandHearth & HomeIntelJohnson & JohnsonLOGAN ALUMINUMMead Westvaco

Finance/Banking

Computer/Information/Telco

Commercial & Industrial

Cingular/AT&T Wireless Next Level Comm.Cisco Systems Q Logic Pac BellComputer Sciences SIACControl Systems Intl Sun MicrosystemsDow Jones Sutro TowersExtreme Networks Telehouse lnt’lGC Micro Texas InstrumentsHarris Corp UnisysIBM VerizonMotorola

MEM SwitchgearMcCarren AirportMetropolitan CouncilMillennium ChemicalMinnesota Corn ProductsMurphy OilMystic Lake CasinoNiagara WaterNucor SteelOhio AerospacePfizer Pharmaceutical, UKPhillip MorrisPowell-ESCOReuters, UKRenault, Slovenia

SANDVIK COROMAT – Sweden

SafewaySharp ElectronicsShell OilSintefSkyguide, SwitzerlandStatoilTexaco, UKTexas PetrochemicalTLT BabcockUnited AirlinesWelsh Traffic, UK

Encore Series Customers

Education

University of North CarolinaUCLA Medical

Federal Reserve BankGoldman SachsHBC Bank UKJP Morgan/ChaseKPMGMorgan StanleyNASDAQNew York Stock ExchangeNomura SecuritiesNYCEThe World BankVisa

City of HopeKaiser Permanente HospitalMD Anderson Medical CenterPresbyterian Health Care

Hospital/Healthcare

San Jacinto Methodist HospitalSutter HealthcareTrillium HealthcareUniv. of Texas Medical Center

Page 5: Encore Presentation Sept 2007

Design Goals• Modularity

• Ability to easily configure the instrument to cost-effectively meet customers applications

• Compliance• Meet (and exceed) all US (IEEE) and International (IEC, EN) Power Quality monitoring

standards

• Communications• Strong and diverse suite of communications

• Compatibility• Allow the customer to continue to use existing assets while taking advantage of the latest

technology

• Visualization• Provide an easy to use local user interface. Web browser based system interface

• Intelligence• Clear and simple event explanations. Apply years of Dranetz-BMI & Electrotek experience

by automatically performing advanced analysis and characterization of data. Answer Modules®

• Innovation• Continue Dranetz-BMI’s legacy of providing unique and innovative solutions to meet the

changing needs of our customers.• Continue to provide the features and benefits our customers expect while improving our

market position.

Encore Series

Page 6: Encore Presentation Sept 2007

System Architecture

Page 7: Encore Presentation Sept 2007

• Encore Series Software• PC compatible, Windows 2000/XP

• Web browser based user interface, supports from 1 to 50+ instruments• Power Quality, Demand, Energy and Process Analysis• Intelligent Answer Modules for automatic advanced analysis• Fully supports Signature System and other Dranetz-BMI products

• Enterprise Software• For large system management and/or advanced analysis• PQView or DranView

• Industrial grade computing platforms• For rugged and harsh environments where a PC is not appropriate• Runs Encore Series Software (see above)• Model 5502 – Compact Flash memory, Model 5504 – Hard Disk memory

• Demonstration site on the internet• Live Encore system monitoring the Dranetz-BMI facility in Edison, NJ USA• IP address: 72.4.197.9. Username: “guest”, Password: “password”

• One time only Java install. Follow the online instructions.

System Software

Page 8: Encore Presentation Sept 2007

Modularity• Encore Series model 61000 has 4 slots within the instrument to

accept various types of measurement modules• 4 Channel voltage• 4 Channel current• 8 Channel digital input

• Each module can be it’s own instrument or combined with other modules to create Virtual Instruments – multiple instruments within one instrument

• Built to order • Customer “builds” the instrument:

1) Select your mainframe. Choose from Standard (61STD) or Switchgear with or without ¼ VGA touch display (61SGD, 61SG)

2) Select the modules needed for your application, up to a total of four.

Model 61000 New!

Page 9: Encore Presentation Sept 2007

Build Your Own Instrument!

4 Channel Voltage Module

4 Channel Current Module

Digital Input Module

Click For Animation

Page 10: Encore Presentation Sept 2007

Benefits of the 61000 Modularity

Encore Series

Before Encore Series

Four separate instruments

After Encore Series

One instrument

$ $ $

€ € €

Reduced Cost!

€ € €

$ $ $

Page 11: Encore Presentation Sept 2007

61000 Compliance• Meets (and exceeds) all US (IEEE) and International (IEC, EN)

Power Quality monitoring standards• 61000-4-30 Class A compliant using technology from 4400/PX5

• Compliance certified by an independent laboratory. Certificate available on www.dranetz-bmi.com

• IEC61000-4-7 second revision, gapless, IEC61000-4-15

• EN50160

• NVE (Norway)

• CREG (Columbia)

• IEEE 1159, IEEE 519, IEEE1453, IEEE1459

Encore Series

Page 12: Encore Presentation Sept 2007
Page 13: Encore Presentation Sept 2007

61000 Communications• Standard built-in

• 10/100BaseT Ethernet - Adaptable to fiber, wireless and others • RS232, RS485

• External (optional)• Analog modem• GSM/GPRS modem

• Communication Protocols• XML (to Encore Series Software), Modbus TCP, RTU

• Cross-Triggering – Internal & external• Internal: Trigger on one channel causes others to record (within 1 instrument)• External: One instrument (or virtual instrument) can tell another to record data to

memory

• GPS• Internal GPS receiver (optional) and external antenna• Encore SW or 5504/5502 (optional)

Encore Series

Page 14: Encore Presentation Sept 2007

Compatibility• New 61000• EPQ family, 5540 family, ADAM family Datanodes• 7100 PQNode• PQView• DranView• Other Dranetz-BMI & Electrotek products

Encore Series Software

Page 15: Encore Presentation Sept 2007

61000 Visualization• Web Browser based remote system level interface via Encore Series

Software

• Local user interface

Encore Series

Switchgear mount with ¼ VGA touch display

19” Rack Mount with ¼ VGA touch display

Page 16: Encore Presentation Sept 2007

Encore Home Page

Page 17: Encore Presentation Sept 2007

Event Summary

Page 18: Encore Presentation Sept 2007

Sample Timeline with Event List

Page 19: Encore Presentation Sept 2007

PQ Event Details

Page 20: Encore Presentation Sept 2007

Sample Energy Trend

Page 21: Encore Presentation Sept 2007

Real Time Meters

Page 22: Encore Presentation Sept 2007

Intelligence • Answer Modules (optional) are part of Encore Series Software and

perform advanced analysis and characterization of data.• Intelligent algorithms that interpret and/or compile data• Available Answer Modules

• Sag/Dip directivity: Did the sag original upstream or downstream• PF capacitor transient detection. Was the source of the transient a PF

cap switching. VAR verifier identifies unbalanced capacitor switching. • Optional VAR Verifier identifies unbalanced capacitor switching.

• UPS: Pass/Fail report that compares data from the input and the output of the UPS to determine if the Ups is mitigating input side problems.

• Energy Usage: Advanced energy analysis and aggregation.• Radial line fault: Estimate the distance to a fault• Oneline: Custom web based graphical user interface of your system.

Encore Series

Page 23: Encore Presentation Sept 2007

Here’s the Data ...

Encore Series

Page 24: Encore Presentation Sept 2007

along with the Information ...

Encore Series

Page 25: Encore Presentation Sept 2007

… that leads to the Answer !

Encore Series

Page 26: Encore Presentation Sept 2007

Encore Series Instrumentation

Page 27: Encore Presentation Sept 2007

Available Instruments• Power Quality, Demand & Energy

• 61000 DataNodeNew!

• 61STD, 61SGNew!, 61SGDNew! mainframes

• 5530T/5520T, 5513T Enhanced Power Quality DataNode

• Demand & Energy• A230, A230s• 5546, 5547, 5548, 5549

• Physical measurements - Transducer and contact monitoring• 61000 digital input • Advantech ADAM DataNode’s

Encore Series

Page 28: Encore Presentation Sept 2007

Encore Model 61000

Page 29: Encore Presentation Sept 2007

• Instrument Mainframes – All have 4 slots• Aluminum Enclosure• Switchgear mount with or without display

• Standard communications• RS232, RS485• Ethernet

• 1GB internal Flash memory• Not removable

• Power Supply• On/Off Switch• Standard enclosure, 12Vdc input

• External AC adapter• Optional 125/220VDC

• Switchgear mount, internal 90-250VAC, 105-125VDC • Built in UPS

• Internal GPS receiver (optional), rear panel connector.

Model 61000 Family

Page 30: Encore Presentation Sept 2007

12VDC Instrument Power Supply

Sample Rear Panel(actual instrument depends on your

configuration)

Voltage/Current Module Pod interface

Current module TR Connectors

Voltage Module Safety Connectors

Ethernet

RS232, RS485

Not Supported

GPS Antenna

Voltage Module Screw Terminals

Power Supply Output for Flex CT’s

Power Supply Output For

GSM

Power Switch

Encore Model 61000

Note: 61STD shown

Page 31: Encore Presentation Sept 2007

• 4 Channel Voltage Module• Range: 0 – 600V, 1000Vpk, DC coupled (AC/DC)

• RMS: 512 Samples/cycle, +/- 0.1% Reading, +/-0.05%FS, over 7KHz bandwidth (1 second RMS readings)

• Standard low and medium frequency transients• Medium freq transient resolution is now 32.5us due to 512

samples/cycle• 4x EPQ DataNode (128s/c, 130us), 2x 4400 (256s/c, 65us)

• Connections available:• 61MVS: Screw Terminals• 61MVB: Safety Connectors• 61MZP: ‘D’ connector for

voltage or current pods

Encore Series

61MZP 61MVS61MVB

5536VPOD

Page 32: Encore Presentation Sept 2007

• 4 Channel Current Module• Range: 0 – 1.5V, DC coupled (AC/DC)

• RMS:  512 Samples/Cycle, +/- 0.1% Reading, +/-0.05%FS, 3KHz bandwidth (1 second RMS readings)

• Standard low and medium frequency transients to 32us

• Connections available:• 61MAC: Dranetz-BMI ‘TR’ type connector• 61MAS5, 61MAS1: 5A or 1A

built in CT. Counts as 2

modules, double wide.• 61MZP: ‘D’ connector for

voltage or current pod

Encore Series

61MAC61MZP

5537APOD

61MAS5, 1

Page 33: Encore Presentation Sept 2007

• 8 Channel Digital Input Module• 61MDIN: Range: 0 – 135VAC/DC • 1KHZ sampling, Edge or level triggered• Logic programmed by user (active high or active low)• Time stamped to the millisecond• Recorded and trended in parallel with voltage and current• Screw terminals• Use instead of InfoNode ADAM modules

• Faster sampling• DataNode is usually closer to the circuit being measured than the

InfoNode

• Applications• General digital input position monitoring such as breaker/switch

position.• Demand interval synchronization. Start and stop interval.• Pulse counting, KYZ metering

Encore Series61MDIN

Page 34: Encore Presentation Sept 2007

• Communications• Built in, standard

• Ethernet• RS232, RS485

• Available• GSM, GPRS modem - 61GPRS, works

in all countries. User supplied SIM• Analog modem – 61MDM

Model 61000 Family

61MDM

61GPRS

Page 35: Encore Presentation Sept 2007

• Mounting• Standard shelf mount• Available

• 19” Rack. Instrument mounts behind the rack panel. • With or without optional color/touch display.

• 61RMTS (no display), 61RMTD (with display)

• Wall/vertical surface using brackets. 61BRKTS• Weather resistant enclosure, 61WENCL

• Available for 61000 and 61000VCM• With or without phase power adapter to power from

phase (61000 only)

Model 61000 Family

61WENCL

61RMTD

Page 36: Encore Presentation Sept 2007

Enhanced Power Quality (EPQ) Models 5530, 5520,

5513

Page 37: Encore Presentation Sept 2007

• Instrument Mainframe• Models 5530, 5520, 5513, 5510 • Aluminum Enclosure

• 13” x 8” x 5”• Standard communications

• Ethernet• AUI – Adaptable to fiber, coax and others

• Power Supply• On/Off Switch• 90-250Vac, 50/60Hz• Optional 105-150Vdc• Built-in UPS

EPQ DataNode

Page 38: Encore Presentation Sept 2007

EPQ Model 5530T, 5510T (no Pods)

Voltage Pod Current Pod

Page 39: Encore Presentation Sept 2007

EPQ Model 5520

EPQ Model 5513(Connectors only shown)

EPQ DataNode

Page 40: Encore Presentation Sept 2007

• Mounting • Standard shelf mount

• Optional• Weather resistant enclosures• 19” Rack mount• Wall mount brackets

EPQ DataNode

Page 41: Encore Presentation Sept 2007

• Models 5530, 5520, 5513• 4 Voltage & 4 Current channels

• 5530, 5520:• 600VAC/DC, 5A or 1A (5530 only) CT Secondary

• 5513:• 600VAC/DC, 1.5V Clamp-on CT, Flex CT, DC CT

• Differential Inputs for direct Delta connections (A-B, B-C, C-A)• 128 samples/cycle • Standard low, medium and high speed peak detected transients to 1us• 1/2 Cycle RMS• IEC Harmonics, Interharmonics• Up to 16 pre/post cycle capture• Ethernet Communications to Encore SW• IEC 61000-4-30 Class B• CE, UL

EPQ DataNode

Page 42: Encore Presentation Sept 2007

DataNode Series A230• 30+ Parameters

• RMS voltage and current, kVA, KVAR, kW, PF, frequency, kWh, demand, VTHD, ITHD.

• Harmonics

• Local Display• Bright 3 Line LED

• Panel Mount, Two Sizes:• A230: 144 x 144 x 46mm

• A230s: 96 x 96 x 46mm

• Screw Terminals for Voltage, Current and Power

Page 43: Encore Presentation Sept 2007

DataNode Series A230• Communications

• RS232, Modbus RTU• Ethernet, Modbus TCP• None

• Instrument Power• 85 to 253V AC/DC, 45 to 400Hz

Rear panel view

Page 44: Encore Presentation Sept 2007

DataNode Series 5540

• 32 Demand & Energy type Parameters• Local Display

• Bright 3 Line LED• Panel Mount• Screw Terminals Voltage• Feed through for Current• 2 wire RS485 Com’s

• Ethernet available using external adapters

Page 45: Encore Presentation Sept 2007

DataNode Series 5540

Power Supply 120VAC or 230VAC

Page 46: Encore Presentation Sept 2007

Enterprise SoftwareEnterprise Software

Page 47: Encore Presentation Sept 2007

DataNode

EncoreSW

Encore

SW

Enterprise SW on PC

(Optional)

LAN, WAN, Internet, Ethernet,

Fiber, Wireless, Modem etc.

DataNode DataNode DataNode DataNode

Encore Series

LAN, WAN, Internet, Ethernet,Fiber, Wireless, Modem etc.

Page 48: Encore Presentation Sept 2007

PQView

• Download Encore SW directly New Feature!

• Automatic or manual downloading

• View event or trended data• Advanced data and statistical analysis• Aggregation• Supports very large systems and databases• Data Manager supports many instruments

from Dranetz-BMI and other manufacturers

Page 49: Encore Presentation Sept 2007

EncoreSW

7100 5540 EPQ

Web Browser

Key

Encore Series

Communications

Instrumentation

Visualization

DataBase

Dranetz-BMI Software

61000

Page 50: Encore Presentation Sept 2007

Web Browser

PQDIF Files

DV 6.0

NodeLink

Key

Encore Series

Communications

Instrumentation

Visualization

DataBase

Dranetz-BMI Software

PQVIEW PQVIEWDB

Enterprise Software

New Feature!

PQView Encore SW DownloadsEncore

SW

7100 5540 EPQ 61000