electronic gas/air ratio control system gb-sxx 06x f01€¦ · (e.g. stocko sto-fit system, eh...

5
Data sheet Multi-functional control with direct-acting pressure regulator Electronic gas/air ratio control system GB-SXX 06X F01 Version 4: As at: 23.04.2018 Page 1 of 5 ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 . 84030 Landshut . Phone: +49 871 707-0 . Fax: +49 871 707-464 . [email protected] . www.ebmpapst.com Technology Multi-functional fitting as per EN 13611 for modulating operation. - Electronic gas/air composite system with modulation 1:10 - Stepper motor with Class C pressure regulator - Double coaxial safety valve - Inlet pressure up to max. 60mbar (6.0kPa) - Different device versions possible depending on application - Heat output: max. 60kW when using G 271, low calorific natural gas Applications - For premixing and fan-assisted burners - Suitable for gases as per EN 437 and other neutral gaseous media Approvals Prototype test certificate as per EC Gas Appliance Directive GB-SXX 06X F01 (CE-0085CM0036 Product ident. no.) Approvals exist for the chief gas consuming countries.

Upload: others

Post on 30-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Electronic gas/air ratio control system GB-SXX 06X F01€¦ · (e.g. Stocko STO-FIT System, EH 705-103; Würth WR-MPC4 series, article no. 649 003 013 322) Stepper motor module: suitable

Data sheet Multi-functional control with direct-acting pressure regulator Electronic gas/air ratio control system GB-SXX 06X F01

Version 4: × As at: 23.04.2018 × Page 1 of 5

ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 . 84030 Landshut . Phone: +49 871 707-0 . Fax: +49 871 707-464 . [email protected] . www.ebmpapst.com

Technology

Multi-functional fitting as per EN 13611 for modulating

operation.

- Electronic gas/air composite system with

modulation 1:10

- Stepper motor with Class C pressure regulator

- Double coaxial safety valve

- Inlet pressure up to max. 60mbar (6.0kPa)

- Different device versions possible depending on

application

- Heat output: max. 60kW

when using G 271, low calorific natural gas

Applications

- For premixing and fan-assisted burners

- Suitable for gases as per EN 437 and other neutral

gaseous media

Approvals

Prototype test certificate as per EC Gas Appliance

Directive

GB-SXX 06X F01 (CE-0085CM0036 Product ident. no.)

Approvals exist for the chief gas consuming countries.

Page 2: Electronic gas/air ratio control system GB-SXX 06X F01€¦ · (e.g. Stocko STO-FIT System, EH 705-103; Würth WR-MPC4 series, article no. 649 003 013 322) Stepper motor module: suitable

Data sheet Multi-functional control with direct-acting pressure regulator Electronic gas/air ratio control system GB-SXX 06X F01

Version 4: × As at: 23.04.2018 × Page 2 of 5

ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 . 84030 Landshut . Phone: +49 871 707-0 . Fax: +49 871 707-464 . [email protected] . www.ebmpapst.com

GasBloc type key

GB- XXXXX XXX XXX SXX XXXXX

Nominal voltage of safety valves (optional) 230 V RAC 50/60 Hz 120 V RAC 50/60 Hz 24 V RAC 50/60 Hz 24 V DC 22 V DC Actuation of V1 and V2 0 = Joint 2 = Separate Outlet pressure Inlet pressure 0 = 0 hPa up to 65 hPa 2 = 1.5 – 20 hPa up to 65 hPa 4 = 3 – 40 hPa up to 65 hPa 6 = 0 – 35 hPa up to 60 hPa Series production (type-independent) Gas train schematic diagram 1 = With servo pressure regulator 2 = Without servo pressure regulator 3 = Direct-acting pressure regulator Valve design 0 = Double safety valve 1 = Single safety valve, right angle 2 = Single safety valve, straight Design type (generation): D, E, F Size Nominal diameter 05 = pmax = 65 mbar 06 = pmax = 60 mbar 5 = ISO 228 – G ½ (DN 15) 7 = ISO 228 – G ¾ (DN 20) Opening behavior and main flow throttle Without = Fast-opening, fast-closing L = Slow-opening E = Adjustable start gas P = Pilot gas connection G = Gas/air composite system M = With modulator coil W = Whirlwind version Z = Two-stage SXX = Stepper motor valve with nominal diameter 5, 8, 12, 15 GasBloc

Description of main components

- Pressure regulator: The Class C pressure regulator provides compensation for pressure fluctuations in

the supply network.

This ensures a constant air flow with a constant step rate and

constant nozzle pressure.

- Safety valves: As per EN161, Class B/C

- Dirt trap: Fine-mesh strainer at the inlet to protect the fitting against particles and other dirt

- Safety valve operating modes: The double safety valves V1 and V2 are designed for mutually independent closing

and are jointly actuated and opened.

- Pressure test nipple: On inlet side

Page 3: Electronic gas/air ratio control system GB-SXX 06X F01€¦ · (e.g. Stocko STO-FIT System, EH 705-103; Würth WR-MPC4 series, article no. 649 003 013 322) Stepper motor module: suitable

Data sheet Multi-functional control with direct-acting pressure regulator Electronic gas/air ratio control system GB-SXX 06X F01

Version 4: × As at: 23.04.2018 × Page 3 of 5

ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 . 84030 Landshut . Phone: +49 871 707-0 . Fax: +49 871 707-464 . [email protected] . www.ebmpapst.com

Functional diagram

Version with G ¾ connection (optionally also G ½)

Dimensions in mm.

Key 1 Dirt trap, strainer 2 Housing 3 Safety valve V1 4 Closing spring V1 5 Armature V1 6 Safety valve V2 7 Closing spring V2 8 Armature V2 9 Solenoid 10 Stepper motor 11 Valve cone 12 Valve seat 13 Control diaphragm 14 Upper spring 15 Lower spring

Electrical connection Safety valve

Pressure test nipple

G 1 ¼″ or G 1 ½″ ISO 228-1

Electrical connection Safety valve

Solenoid coil

Page 4: Electronic gas/air ratio control system GB-SXX 06X F01€¦ · (e.g. Stocko STO-FIT System, EH 705-103; Würth WR-MPC4 series, article no. 649 003 013 322) Stepper motor module: suitable

Data sheet Multi-functional control with direct-acting pressure regulator Electronic gas/air ratio control system GB-SXX 06X F01

Version 4: × As at: 23.04.2018 × Page 4 of 5

ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 . 84030 Landshut . Phone: +49 871 707-0 . Fax: +49 871 707-464 . [email protected] . www.ebmpapst.com

Capacity curve

Typical modulation characteristics

Key empfohlener Arbeitsbereich = Recommended operating range Bedingungen = Conditions

Page 5: Electronic gas/air ratio control system GB-SXX 06X F01€¦ · (e.g. Stocko STO-FIT System, EH 705-103; Würth WR-MPC4 series, article no. 649 003 013 322) Stepper motor module: suitable

Data sheet Multi-functional control with direct-acting pressure regulator Electronic gas/air ratio control system GB-SXX 06X F01

Version 4: × As at: 23.04.2018 × Page 5 of 5

ebm-papst Landshut GmbH Hofmark-Aich-Str. 25 . 84030 Landshut . Phone: +49 871 707-0 . Fax: +49 871 707-464 . [email protected] . www.ebmpapst.com

Technical data

Nominal diameter DN 15/DN 20

Main gas connection (inlet) External thread ISO 228 – G ½″ (DN 15); ISO 228 – G ¾″ (DN 20)

Outlet Special ebm-papst quick connector, integrated

Maximum inlet pressure 60mbar (6.0kPa)

Nominal flow rate 2.1m3/h (air) at Dp 5mbar with nominal diameter 8mm

2.9m3/h (air) at Dp 5mbar with nominal diameter 12mm

Ambient temperature -15° C to 70° C with NG or SNG (family 1 and 2)

0° C to 70° C with LPG (family 3)

Designed Lifetime 500,000 cycles or 10 years according EN 126/EN161 (Afecor/VHB) depending on the time temperature profile

Automatic shut-off valves Class B/C as per EN126

Group 1

Pressure regulator Class C

Degree of protection IP 40 in combination with suitable connector for safety module and

stepper motor module

Opening time < 1s

ON time 100%

Safety module:

Voltage/frequency/load

230 V RAC / 50/60Hz / 9.8VA (coil color: red)

24 V RAC / 50/60Hz / 9.8VA (coil color: gray)

24 VDC / 9.8VA (coil color: blue)

22 VDC / 9.7VA (coil color: green)

Optional: 120 V RAC / 50/60Hz / 9.8VA (coil color: yellow)

Stepper motor module:

Voltage/load

24 VDC, unipolar 1.8VA at 200Hz

Electrical connection Safety module: suitable for connector housing with pitch 4.20mm

(e.g. Stocko STO-FIT System, EH 705-103; Würth WR-MPC4 series,

article no. 649 003 013 322)

Stepper motor module: suitable for connector housing Stocko-Grid MH790-06-001

Mounting position Solenoid at any position between vertical and horizontal –

but not upside down

Maximum attitude of site 4,000m above sea level (EN 60664-1)

Degree of contamination 3 (EN 60730-1)