Page 1 of 161 Report No.: MIL05-043 ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ACCELERATOR CENTER SPACECRAFT INTERFACE UNIT (SIU), LAT-DS-01862 MIL-STD-461E (1999), SECTIONS CE102, RE101, RE102, RS101 AND RS103 MIL-STD-462 SECTIONS: CS102 (NOTICE 5 1986) AND CS06 (NOTICE 3 1971) TESTING IN ACCORDANCE WITH TEST PLAN TP05-83492-1 DATE OF ISSUE: NOVEMBER 3, 2005 PREPARED FOR: Stanford Linear Accelerator Center 2575 Sand Hill Road MS: 96 Menlo Park, CA 94025 PREPARED BY: Valerie Honsinger CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 P.O. No.: 0000056078 W.O. No.: 83492 Date of test: October 19 - 26, 2005 Report No.: MIL05-043 This report contains a total of 161 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as identified herein.

Upload: truonghanh

Post on 25-Mar-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 1 of 161Report No.: MIL05-043

ELECTROMAGNETIC INTERFERENCE TEST REPORT

FOR THE STANFORD LINEAR ACCELERATOR CENTER

SPACECRAFT INTERFACE UNIT (SIU), LAT-DS-01862

MIL-STD-461E (1999), SECTIONS CE102, RE101, RE102, RS101 AND RS103MIL-STD-462 SECTIONS: CS102 (NOTICE 5 1986) AND CS06 (NOTICE 3 1971)

TESTING IN ACCORDANCE WITH TEST PLAN TP05-83492-1

DATE OF ISSUE: NOVEMBER 3, 2005

PREPARED FOR:

Stanford Linear Accelerator Center2575 Sand Hill Road MS: 96Menlo Park, CA 94025

PREPARED BY:

Valerie HonsingerCKC Laboratories, Inc.5046 Sierra Pines DriveMariposa, CA 95338

P.O. No.: 0000056078W.O. No.: 83492

Date of test: October 19 - 26, 2005

Report No.: MIL05-043

This report contains a total of 161 pages and may be reproduced in full only. Partial reproduction may only be donewith the written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, asidentified herein.

Page 2: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 2 of 161Report No.: MIL05-043

TABLE OF CONTENTS

Administrative Information .............................................................................................3Approvals.........................................................................................................................4Unit Under Test (UUT) Description ................................................................................5Unit Under Test ...............................................................................................................5Peripheral Devices ...........................................................................................................5Summary of Results.........................................................................................................6Report of Measurements ..................................................................................................8

CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz........................8CECM – Conducted Emissions, Common Mode, DC to 150MHz .....................26RE101 - Radiated Emissions, Magnetic Field, 30Hz to 100kHz.........................36RE102 - Radiated Emissions, Electric Field, 10kHz to 18GHz ..........................56CS06 - Conducted Susceptibility, Spikes on Power Leads .................................125CS102 - Conducted Susceptibility, Power Leads, 10kHz to 10MHz ..................130CSCM - Conducted Susceptibility, Common Mode, 30Hz to 150MHz..............137RS101 - Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz ...................142RS103 - Radiated Susceptibility, Electric Field, 10kHz to 18GHz .....................148

Test Log ...........................................................................................................................155

Page 3: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 3 of 161Report No.: MIL05-043

ADMINISTRATIVE INFORMATION

SCOPE:To demonstrate testing of the Spacecraft Interface Unit (SIU), LAT-DS-01862 with therequirements for MIL-STD-461E and MIL-STD-462D in accordance with test plan TP05-83492-1.

CONTRACT NUMBERS:NA

APPLICABLE DOCUMENTS:1. MIL-STD-461E - Electromagnetic Emission and Susceptibility Requirements for the Control

of Electromagnetic Interference2. MIL-STD-462E - .Measurements of Electromagnetic Interference Characteristics3. MIL-STD-464A – Electromagnetic Environmental Effects Requirements for Systems4. 433-RQMT-0005, Rev A – GLAST Observatory Electromagnetic Interference (EMI)

Requirements Document, NASA/GSFC, Oct 6, 20035. MIL-STD-45662 Calibration Systems Requirements6. LAT-MD-00408 - “LAT Instrument Performance Verification Plan”, SLAC7. LAT-SS-00778 – LAT Environmental Specification, SLAC, M. Nordby8. CKC Test Procedure: TP05-83492-1

MANUFACTURER:Stanford Linear Accelerator Center2575 Sand Hill Road MS: 96Menlo Park, CA 94025

REPRESENTATIVE:Dave Nelson

TEST LOCATION:CKC Laboratories, Inc.1120 Fulton PlaceFremont, CA 94539

Page 4: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 4 of 161Report No.: MIL05-043

FREMONT, CA MILITARY CHAMBERThe CKC Laboratories, Inc. Fremont EMI Chamber used for the testing was a 16' x 16' x 10'high shielded enclosure designed to attenuate radio frequency noise over 80 dB up to 1GHz, andover 60 dB at 18GHz. The enclosure uses ferrite tiles with foam anechoic material in key areasto achieve uniform testing from 1MHz to 40GHz. Power brought into the room is filtered over100 dB for frequencies over 14kHz. All emissions measurement equipment is operated fromisolation transformers, which help eliminate the possibility of ground loops. All lighting in thelaboratory is filtered to reduce electrical noise. In addition, incandescent lights are used duringemissions testing to further reduce the potential for electrical noise. The ground plane in thechamber consists of a 3'3” x 12' x 0.020" thick copper sheet bonded to the shield room wall with0.1 mW of bonding resistance.

APPROVALS

QUALITY ASSURANCE: TEST PERSONNEL:

Steve Behm, Director of Engineering Services Amrinder Brar, Lab Manager

Joyce Walker, Quality Assurance AdministrativeManager

Page 5: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 5 of 161Report No.: MIL05-043

UNIT UNDER TEST (UUT) DESCRIPTION

UNIT UNDER TEST

Spacecraft Interface Unit (SIU)Manuf: Stanford LinearModel: LAT-DS-01862Serial: GLAT 2508

PERIPHERAL DEVICES

The UUT was tested with the following peripheral device(s):

Power SupplyManuf: AEMC InstrumentsModel: AX502Serial: PC70344

VME CrateManuf: DawnModel: 11-1011777-2119Serial: 002563

MouseManuf: Dell by MicrosoftModel: X06-08477Serial: NA

KeyboardManuf: DellModel: 04N454Serial: TH-04N454-37171-33F-E488

MonitorManuf: DellModel: MX-D9J367-47605-379-AYKJSerial: PC65341

PCManuf: DellModel: DHMSerial: JLJJ331

Page 6: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 6 of 161Report No.: MIL05-043

SUMMARY OF RESULTSAs received, the Stanford Linear Accelerator Center Spacecraft Interface Unit (SIU), LAT-DS-01862 was tested to following standards and specifications:

Test Description Results OutcomeCE102 - ConductedEmissions, PowerLeads, 10kHz to10MHz

No emissions exceeding the limit were observed from10kHz to 10MHz on the 28VDC Input Power Lead andon the 28VDC Return Lead with input power set to28VDC.

PASS

CECM - ConductedEmissions,Common Mode,DC to 150 MHz

No emissions exceeding the limit were observed on the28VDC Input Power Lead and on the 28VDC ReturnLead to 150MHz.

PASS

RE101 – RadiatedEmissions, 20Hz to50kHz

No out of spec emissions were observed exceeding the7cm and 50cm limits from 30Hz to 100kHz on the Backconnectors, Left, Front, Right and Top sides of theUUT.

PASS

RE102 - RadiatedEmissions, 10kHzto 18GHz

The UUT exhibited no out of spec emissions from10kHz to 30MHz in Vertical polarization and from30MHz to 18GHz in Vertical and Horizontal antennapolarizations.

PASS

CS06 – ConductedSusceptibility,Spikes on PowerLeads

The UUT exhibited no signs of susceptibility during theextent of the testing on the 28VDC Input Power Line,the 28VDC Return Line.

PASS

CS102 – ConductedSusceptibility,Power Leads,10kHz to 10MHz

The UUT exhibited no signs of susceptibility during theextent of the testing from 10kHz to 10MHz on the28VDC Power and 28VDC Return Lines.

PASS

CSCM –ConductedSusceptibility,Common Mode,30Hz to 150MHz

The UUT exhibited no signs of susceptibility during theextent of the testing from 30Hz to 150MHz on the28VDC Input Power Line, the 28VDC Return Line.

PASS

Page 7: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 7 of 161Report No.: MIL05-043

Test Description Results OutcomeRS101 - RadiatedSusceptibility,Magnetic Field,20Hz to 50kHz

The UUT showed no signs of susceptibility during theextent of the testing from 30Hz to 50kHz on the front,back, right side, left side and top faces of the UUT attest levels exceeding the levels specified in FigureRS101-2.

PASS

RS103 – RadiatedSusceptibility,Electric Field,10kHz to 18GHz

The UUT showed no signs of susceptibility during theextent of the testing at 1V/m from 30MHz to 18GHz inhorizontal and vertical antenna polarizations.

PASS

Page 8: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 8 of 161Report No.: MIL05-043

REPORT OF MEASUREMENTS

CE102 - Conducted Emissions, Power Leads, 10kHz to 10MHz

Test EquipmentFunction Asset # S/N Cal Date Cal DueSA - E4446A 02668 US44300408 01/13/2005 01/13/2007Cable P05309 None 08/01/2005 08/01/2007Cable RG214/U 02410 None 06/07/2004 06/07/2006Andrew Cable 1184 CNT-195 01/03/2005 01/03/2007Current Probe F-35 00731 296 05/07/2003 05/07/2005Oscilloscope 00697 US35420829 08/31/2005 08/31/2007

Test ProcedureThe signal generator was connected to the input of the LISN. The signal was injected a signal at10kHz at 6dB below the limit line and the LISN output was measured on the oscilloscope. Thecheck was repeated at 100kHz, 2MHz and 10MHz. The check was also repeated on allremaining LISNs.

The UUT was powered up in standard operating mode. A test cable was connected from themonitor port on the 28VDC Input Power LISN through 20dB of attenuation to the measurementsystem. A 50Ω termination was placed on the monitor port of the other LISNs. The emissionswere measured from 10kHz to 10MHz. Then, the test cable was moved to the 28VDC ReturnLISN and the 50Ω termination was placed on the other LISN monitor ports. The emissions weremeasured from 10kHz to 10MHz.

Page 9: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 9 of 161Report No.: MIL05-043

CE102 Conducted Emissions, Power Leads Pre-Calibration

CE102 Conducted Emissions, Power Leads Test Setup

Page 10: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 10 of 161Report No.: MIL05-043

CE102 Conducted Emissions, Power Leads Closeup

Seq. # Test Description Test Lead / Conditions0 Conducted Emissions Pre-Cal @ 10kHz0 Conducted Emissions Pre-Cal @ 2MHz0 Conducted Emissions Pre-Cal @ 10MHz20 Conducted Emissions Positive Lead / Grounded to copper table as it exits cage

and chamber wall before coming into chamber.21 Conducted Emissions Return Lead / Grounded to copper table as it exits cage

and chamber wall before coming into chamber.

Page 11: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 11 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: CE102 MIL-STD-462Work Order #: 83492 Date: 10/20/2005Test Type: Conducted Emissions Time: 3:58:36 PMEquipment: Spacecraft Interface Unit Sequence#: 0Manufacturer: Stanford Linear Tested By: A. BrarModel: Stanford Linear Accelerator Center 28V DCS/N: GLAT 2508

Equipment Under Test (* = EUT):Function Manufacturer Model # S/NSpacecraft Interface Unit* Stanford Linear Stanford Linear Accelerator Center GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Pre-Cal Sweep. Signal at 10KHz. Injecting current which is 6dB below the limit though a 50 ohms load, andexpecting to see -6dB +/-3dB from the limit.

Transducer Legend:T1=Cable 2410T3=CMP F-35 SN 296

T2=Cable P05309

Measurement Data: Reading listed by margin. Test Lead: Pre-Cal# Freq Rdng T1 T2 T3 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV dBµV dB Ant 1 10.000k 46.9 +0.0 57.8 66.0 -8.2 Pre-C +0.1 -0.1 +10.9

2 40.780k 20.6 +0.0 24.1 66.0 -41.9 Pre-C +0.1 +0.0 +3.4

3 12.429k 8.9 +0.0 18.5 66.0 -47.5 Pre-C +0.1 -0.1 +9.6

4 13.239k 8.2 +0.0 17.4 66.0 -48.6 Pre-C +0.1 -0.1 +9.2

5 14.049k 7.0 +0.0 15.8 66.0 -50.2 Pre-C +0.1 -0.1 +8.8

Page 12: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 12 of 161Report No.: MIL05-043

6 14.499k 6.9 +0.0 15.6 66.0 -50.4 Pre-C +0.1 +0.0 +8.6

7 14.229k 6.3 +0.0 15.2 66.0 -50.8 Pre-C +0.1 +0.0 +8.8

8 19.989k 7.9 +0.0 14.7 66.0 -51.3 Pre-C +0.1 +0.0 +6.7

9 17.019k 5.4 +0.0 13.2 66.0 -52.8 Pre-C +0.1 +0.0 +7.7

10 18.099k 5.8 +0.0 13.2 66.0 -52.8 Pre-C +0.1 +0.0 +7.3

11 20.799k 6.1 +0.0 12.7 66.0 -53.3 Pre-C +0.1 +0.0 +6.5

12 21.339k 5.4 +0.0 11.9 66.0 -54.1 Pre-C +0.1 +0.0 +6.4

13 22.239k 5.6 +0.0 11.9 66.0 -54.1 Pre-C +0.1 +0.0 +6.2

14 29.709k 4.8 +0.0 9.6 66.0 -56.4 Pre-C +0.1 +0.0 +4.7

15 25.299k 3.6 +0.0 9.2 66.0 -56.8 Pre-C +0.1 +0.0 +5.5

16 26.289k 3.3 +0.0 8.7 66.0 -57.3 Pre-C +0.1 +0.0 +5.3

17 32.230k 4.2 +0.0 8.6 66.0 -57.4 Pre-C +0.1 +0.0 +4.3

18 27.369k 2.5 +0.0 7.7 66.0 -58.3 Pre-C +0.1 +0.0 +5.1

19 33.040k 3.2 +0.0 7.5 66.0 -58.5 Pre-C +0.1 +0.0 +4.2

20 34.660k 3.3 +0.0 7.4 66.0 -58.6 Pre-C +0.1 +0.0 +4.0

21 35.290k 2.8 +0.0 6.9 66.0 -59.1 Pre-C +0.1 +0.0 +4.0

22 47.080k 3.5 +0.0 6.8 66.0 -59.2 Pre-C +0.1 +0.1 +3.1

23 44.560k 3.3 +0.0 6.6 66.0 -59.4 Pre-C +0.1 +0.0 +3.2

24 45.010k 2.9 +0.0 6.3 66.0 -59.7 Pre-C +0.1 +0.1 +3.2

25 34.030k 1.9 +0.0 6.1 66.0 -59.9 Pre-C +0.1 +0.0 +4.1

26 36.010k 2.0 +0.0 6.0 66.0 -60.0 Pre-C +0.1 +0.0 +3.9

Page 13: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 13 of 161Report No.: MIL05-043

27 43.840k 2.6 +0.0 6.0 66.0 -60.0 Pre-C +0.1 +0.0 +3.3

28 32.680k 1.2 +0.0 5.6 66.0 -60.4 Pre-C +0.1 +0.0 +4.3

29 47.800k 2.3 +0.0 5.5 66.0 -60.5 Pre-C +0.1 +0.1 +3.0

30 49.420k 2.2 +0.0 5.3 66.0 -60.7 Pre-C +0.1 +0.1 +2.9

Page 14: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 14 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: CE102 MIL-STD-462Work Order #: 83492 Date: 10/20/2005Test Type: Conducted Emissions Time: 4:27:49 PMEquipment: Spacecraft Interface Unit Sequence#: 0Manufacturer: Stanford Linear Tested By: A. BrarModel: Stanford Linear Accelerator Center 28V DCS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NSpacecraft Interface Unit* Stanford Linear Stanford Linear Accelerator Center GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Pre-Cal Sweep. Signal at 2MHz. Injecting current which is 6dB below the limit though a 50 ohms load, andexpecting to see -6dB +/-3dB from the limit.

Transducer Legend:T1=Cable 2410T3=4' Cable AN 01184

T2=Cable P05309T4=CMP F-35 SN 296

Measurement Data: Reading listed by margin. Test Lead: Pre-Cal# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV dBµV dB Ant 1 1.996M 97.4 +0.0 98.7 105.0 -6.3 Pre-C +0.1 +0.0 +0.0 +1.2

2 5.988M 54.5 +0.0 55.6 85.1 -29.5 Pre-C +0.1 +0.0 +0.0 +1.0

3 7.983M 47.2 +0.0 48.5 82.3 -33.8 Pre-C +0.2 +0.1 +0.0 +1.0

4 9.985M 43.6 +0.0 44.9 80.0 -35.1 Pre-C +0.2 +0.1 +0.0 +1.0

5 40.060k 24.6 +0.0 28.2 66.0 -37.8 Pre-C +0.1 +0.0 +0.0 +3.5

Page 15: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 15 of 161Report No.: MIL05-043

6 80.111k 23.2 +0.0 25.5 66.0 -40.5 Pre-C +0.0 +0.0 +0.1 +2.2

7 3.992M 49.1 +0.0 50.5 92.0 -41.5 Pre-C +0.2 +0.0 +0.1 +1.1

8 39.340k 19.9 +0.0 23.6 66.0 -42.4 Pre-C +0.1 +0.0 +0.0 +3.6

9 10.899k 13.1 +0.0 23.5 66.0 -42.5 Pre-C +0.1 -0.1 +0.0 +10.4

10 12.249k 13.1 +0.0 22.8 66.0 -43.2 Pre-C +0.1 -0.1 +0.0 +9.7

11 64.360k 19.5 +0.0 22.0 66.0 -44.0 Pre-C +0.0 +0.0 +0.0 +2.5

12 69.580k 19.5 +0.0 22.0 66.0 -44.0 Pre-C +0.1 +0.0 +0.0 +2.4

13 18.189k 14.5 +0.0 21.9 66.0 -44.1 Pre-C +0.1 +0.0 +0.0 +7.3

14 24.489k 15.9 +0.0 21.7 66.0 -44.3 Pre-C +0.1 +0.0 +0.0 +5.7

15 13.509k 12.5 +0.0 21.6 66.0 -44.4 Pre-C +0.1 -0.1 +0.0 +9.1

16 53.110k 18.6 +0.0 21.6 66.0 -44.4 Pre-C +0.1 +0.1 +0.0 +2.8

17 14.769k 12.9 +0.0 21.5 66.0 -44.5 Pre-C +0.1 +0.0 +0.0 +8.5

18 32.680k 16.9 +0.0 21.3 66.0 -44.7 Pre-C +0.1 +0.0 +0.0 +4.3

19 76.150k 18.9 +0.0 21.3 66.0 -44.7 Pre-C +0.0 +0.0 +0.1 +2.3

20 13.779k 12.2 +0.0 21.2 66.0 -44.8 Pre-C +0.1 -0.1 +0.0 +9.0

21 15.669k 12.8 +0.0 21.1 66.0 -44.9 Pre-C +0.1 +0.0 +0.0 +8.2

22 24.039k 15.3 +0.0 21.1 66.0 -44.9 Pre-C +0.1 +0.0 +0.0 +5.7

23 85.511k 18.8 +0.0 21.0 66.0 -45.0 Pre-C +0.1 +0.0 +0.0 +2.1

24 20.349k 14.2 +0.0 20.9 66.0 -45.1 Pre-C +0.1 +0.0 +0.0 +6.6

25 59.410k 17.9 +0.0 20.5 66.0 -45.5 Pre-C +0.0 +0.0 +0.0 +2.6

26 87.761k 18.1 +0.0 20.3 66.0 -45.7 Pre-C +0.1 +0.0 +0.0 +2.1

Page 16: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 16 of 161Report No.: MIL05-043

27 72.550k 17.8 +0.0 20.2 66.0 -45.8 Pre-C +0.1 +0.0 +0.0 +2.3

28 83.891k 17.9 +0.0 20.2 66.0 -45.8 Pre-C +0.0 +0.0 +0.1 +2.2

29 88.661k 18.0 +0.0 20.2 66.0 -45.8 Pre-C +0.1 +0.0 +0.0 +2.1

30 45.280k 16.7 +0.0 20.1 66.0 -45.9 Pre-C +0.1 +0.1 +0.0 +3.2

Page 17: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 17 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: CE102 MIL-STD-462Work Order #: 83492 Date: 10/20/2005Test Type: Conducted Emissions Time: 4:34:28 PMEquipment: Spacecraft Interface Unit Sequence#: 0Manufacturer: Stanford Linear Tested By: A. BrarModel: Stanford Linear Accelerator Center 28V DCS/N: GLAT 2508

Equipment Under Test (* = EUT):Function Manufacturer Model # S/NSpacecraft Interface Unit* Stanford Linear Stanford Linear Accelerator Center GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Pre-Cal Sweep. Signal at 10MHz. Injecting current which is 6dB below the limit though a 50 ohms load, andexpecting to see -6dB +/-3dB from the limit.

Transducer Legend:T1=Cable 2410T3=CMP F-35 SN 296

T2=Cable P05309

Measurement Data: Reading listed by margin. Test Lead: Pre-Cal# Freq Rdng T1 T2 T3 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV dBµV dB Ant 1 9.903M 73.2 +0.0 74.5 80.1 -5.6 Pre-C +0.2 +0.1 +1.0

2 40.330k 20.4 +0.0 24.0 66.0 -42.0 Pre-C +0.1 +0.0 +3.5

3 10.539k 8.7 +0.0 19.3 66.0 -46.7 Pre-C +0.1 -0.1 +10.6

4 11.169k 7.0 +0.0 17.2 66.0 -48.8 Pre-C +0.1 -0.1 +10.2

5 10.989k 6.6 +0.0 16.9 66.0 -49.1 Pre-C +0.1 -0.1 +10.3

Page 18: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 18 of 161Report No.: MIL05-043

6 12.159k 7.1 +0.0 16.8 66.0 -49.2 Pre-C +0.1 -0.1 +9.7

7 12.879k 7.2 +0.0 16.6 66.0 -49.4 Pre-C +0.1 -0.1 +9.4

8 13.149k 7.4 +0.0 16.6 66.0 -49.4 Pre-C +0.1 -0.1 +9.2

9 15.489k 7.6 +0.0 15.9 66.0 -50.1 Pre-C +0.1 +0.0 +8.2

10 15.849k 7.7 +0.0 15.9 66.0 -50.1 Pre-C +0.1 +0.0 +8.1

11 15.039k 6.5 +0.0 15.0 66.0 -51.0 Pre-C +0.1 +0.0 +8.4

12 16.209k 6.0 +0.0 14.1 66.0 -51.9 Pre-C +0.1 +0.0 +8.0

13 17.469k 6.1 +0.0 13.7 66.0 -52.3 Pre-C +0.1 +0.0 +7.5

14 18.369k 6.3 +0.0 13.6 66.0 -52.4 Pre-C +0.1 +0.0 +7.2

15 20.619k 6.0 +0.0 12.6 66.0 -53.4 Pre-C +0.1 +0.0 +6.5

16 22.509k 6.4 +0.0 12.6 66.0 -53.4 Pre-C +0.1 +0.0 +6.1

17 21.789k 5.2 +0.0 11.6 66.0 -54.4 Pre-C +0.1 +0.0 +6.3

18 23.769k 5.7 +0.0 11.6 66.0 -54.4 Pre-C +0.1 +0.0 +5.8

19 25.839k 5.5 +0.0 11.0 66.0 -55.0 Pre-C +0.1 +0.0 +5.4

20 25.209k 4.3 +0.0 9.9 66.0 -56.1 Pre-C +0.1 +0.0 +5.5

21 24.669k 4.0 +0.0 9.7 66.0 -56.3 Pre-C +0.1 +0.0 +5.6

22 33.670k 5.2 +0.0 9.5 66.0 -56.5 Pre-C +0.1 +0.0 +4.2

23 26.289k 3.4 +0.0 8.8 66.0 -57.2 Pre-C +0.1 +0.0 +5.3

24 38.080k 4.5 +0.0 8.3 66.0 -57.7 Pre-C +0.1 +0.0 +3.7

25 30.249k 3.4 +0.0 8.1 66.0 -57.9 Pre-C +0.1 +0.0 +4.6

26 36.100k 2.9 +0.0 6.9 66.0 -59.1 Pre-C +0.1 +0.0 +3.9

Page 19: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 19 of 161Report No.: MIL05-043

27 48.250k 3.7 +0.0 6.9 66.0 -59.1 Pre-C +0.1 +0.1 +3.0

28 31.959k 1.8 +0.0 6.3 66.0 -59.7 Pre-C +0.1 +0.0 +4.4

29 32.770k 1.9 +0.0 6.3 66.0 -59.7 Pre-C +0.1 +0.0 +4.3

30 45.370k 2.0 +0.0 5.4 66.0 -60.6 Pre-C +0.1 +0.1 +3.2

Page 20: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 20 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: CE102 MIL-STD-462Work Order #: 83492 Date: 10/20/2005Test Type: Conducted Emissions Time: 4:42:12 PMEquipment: Stanford Linear Accelerator Center Sequence#: 20Manufacturer: Stanford Linear Tested By: A. BrarModel: SIU 28V DCS/N: GLAT 2508

Equipment Under Test (* = EUT):Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Cable 2410T3=CMP F-35 SN 296

T2=Cable P05309

Measurement Data: Reading listed by margin. Test Lead: Positive# Freq Rdng T1 T2 T3 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV dBµV dB Ant 1 12.339k 52.8 +0.0 62.4 66.0 -3.6 Posit +0.1 -0.1 +9.6

2 14.229k 52.2 +0.0 61.1 66.0 -4.9 Posit +0.1 +0.0 +8.8

3 10.629k 50.5 +0.0 61.0 66.0 -5.0 Posit +0.1 -0.1 +10.5

4 17.829k 51.7 +0.0 59.2 66.0 -6.8 Posit +0.1 +0.0 +7.4

5 19.719k 49.5 +0.0 56.4 66.0 -9.6 Posit +0.1 +0.0 +6.8

Page 21: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 21 of 161Report No.: MIL05-043

6 23.319k 46.9 +0.0 52.9 66.0 -13.1 Posit +0.1 +0.0 +5.9

7 21.429k 43.3 +0.0 49.7 66.0 -16.3 Posit +0.1 +0.0 +6.3

8 95.231k 46.9 +0.0 48.9 66.0 -17.1 Posit +0.0 +0.0 +2.0

9 26.919k 43.0 +0.0 48.3 66.0 -17.7 Posit +0.1 +0.0 +5.2

10 25.029k 37.4 +0.0 43.0 66.0 -23.0 Posit +0.1 +0.0 +5.5

11 46.360k 38.7 +0.0 42.0 66.0 -24.0 Posit +0.1 +0.1 +3.1

12 28.629k 34.1 +0.0 39.0 66.0 -27.0 Posit +0.1 +0.0 +4.8

13 30.519k 34.4 +0.0 39.0 66.0 -27.0 Posit +0.1 +0.0 +4.5

14 97.031k 36.8 +0.0 38.8 66.0 -27.2 Posit +0.0 +0.0 +2.0

15 93.431k 33.9 +0.0 36.0 66.0 -30.0 Posit +0.1 +0.0 +2.0

16 10.359k 25.0 +0.0 35.7 66.0 -30.3 Posit +0.1 -0.1 +10.7

17 67.780k 30.8 +0.0 33.3 66.0 -32.7 Posit +0.1 +0.0 +2.4

18 13.239k 23.2 +0.0 32.4 66.0 -33.6 Posit +0.1 -0.1 +9.2

19 32.230k 27.8 +0.0 32.2 66.0 -33.8 Posit +0.1 +0.0 +4.3

20 16.389k 24.1 +0.0 32.1 66.0 -33.9 Posit +0.1 +0.0 +7.9

21 49.150k 29.0 +0.0 32.1 66.0 -33.9 Posit +0.1 +0.1 +2.9

22 19.899k 25.2 +0.0 32.0 66.0 -34.0 Posit +0.1 +0.0 +6.7

23 20.349k 25.2 +0.0 31.9 66.0 -34.1 Posit +0.1 +0.0 +6.6

24 21.069k 24.0 +0.0 30.5 66.0 -35.5 Posit +0.1 +0.0 +6.4

25 16.659k 22.0 +0.0 29.9 66.0 -36.1 Posit +0.1 +0.0 +7.8

26 24.399k 24.1 +0.0 29.9 66.0 -36.1 Posit +0.1 +0.0 +5.7

Page 22: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 22 of 161Report No.: MIL05-043

27 18.099k 22.4 +0.0 29.8 66.0 -36.2 Posit +0.1 +0.0 +7.3

28 20.169k 23.0 +0.0 29.8 66.0 -36.2 Posit +0.1 +0.0 +6.7

29 42.940k 25.4 +0.0 28.8 66.0 -37.2 Posit +0.1 +0.0 +3.3

30 50.230k 25.4 +0.0 28.5 66.0 -37.5 Posit +0.1 +0.1 +2.9

Page 23: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 23 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: CE102 MIL-STD-462Work Order #: 83492 Date: 10/20/2005Test Type: Conducted Emissions Time: 4:46:35 PMEquipment: Stanford Linear Accelerator Center Sequence#: 21Manufacturer: Stanford Linear Tested By: A. BrarModel: SIU 28V DCS/N: GLAT 2508

Equipment Under Test (* = EUT):Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Cable 2410T3=CMP F-35 SN 296

T2=Cable P05309

Measurement Data: Reading listed by margin. Test Lead: DC Return# Freq Rdng T1 T2 T3 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV dBµV dB Ant 1 10.179k 52.3 +0.0 63.1 66.0 -2.9 DC Re +0.1 -0.1 +10.8

2 13.419k 52.9 +0.0 62.0 66.0 -4.0 DC Re +0.1 -0.1 +9.1

3 15.489k 52.2 +0.0 60.5 66.0 -5.5 DC Re +0.1 +0.0 +8.2

4 17.289k 52.1 +0.0 59.8 66.0 -6.2 DC Re +0.1 +0.0 +7.6

5 11.889k 49.6 +0.0 59.5 66.0 -6.5 DC Re +0.1 -0.1 +9.9

6 19.089k 48.4 +0.0 55.5 66.0 -10.5 DC Re +0.1 +0.0 +7.0

Page 24: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 24 of 161Report No.: MIL05-043

7 20.979k 48.1 +0.0 54.7 66.0 -11.3 DC Re +0.1 +0.0 +6.5

8 95.681k 43.6 +0.0 45.6 66.0 -20.4 DC Re +0.0 +0.0 +2.0

9 22.689k 38.5 +0.0 44.6 66.0 -21.4 DC Re +0.1 +0.0 +6.0

10 26.289k 38.1 +0.0 43.5 66.0 -22.5 DC Re +0.1 +0.0 +5.3

11 28.179k 38.4 +0.0 43.4 66.0 -22.6 DC Re +0.1 +0.0 +4.9

12 94.691k 40.7 +0.0 42.8 66.0 -23.2 DC Re +0.1 +0.0 +2.0

13 46.090k 38.7 +0.0 42.0 66.0 -24.0 DC Re +0.1 +0.1 +3.1

14 31.779k 33.4 +0.0 37.9 66.0 -28.1 DC Re +0.1 +0.0 +4.4

15 47.440k 34.5 +0.0 37.7 66.0 -28.3 DC Re +0.1 +0.1 +3.0

16 92.801k 33.6 +0.0 35.7 66.0 -30.3 DC Re +0.1 +0.0 +2.0

17 13.149k 24.8 +0.0 34.0 66.0 -32.0 DC Re +0.1 -0.1 +9.2

18 10.899k 22.8 +0.0 33.2 66.0 -32.8 DC Re +0.1 -0.1 +10.4

19 72.190k 30.5 +0.0 33.0 66.0 -33.0 DC Re +0.1 +0.0 +2.4

20 14.949k 24.2 +0.0 32.8 66.0 -33.2 DC Re +0.1 +0.0 +8.5

21 10.449k 21.7 +0.0 32.3 66.0 -33.7 DC Re +0.1 -0.1 +10.6

22 11.259k 22.0 +0.0 32.2 66.0 -33.8 DC Re +0.1 -0.1 +10.2

23 11.709k 22.3 +0.0 32.2 66.0 -33.8 DC Re +0.1 -0.1 +9.9

24 29.889k 27.5 +0.0 32.2 66.0 -33.8 DC Re +0.1 +0.0 +4.6

25 21.159k 25.3 +0.0 31.8 66.0 -34.2 DC Re +0.1 +0.0 +6.4

26 19.719k 24.3 +0.0 31.2 66.0 -34.8 DC Re +0.1 +0.0 +6.8

Page 25: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 25 of 161Report No.: MIL05-043

27 24.579k 25.5 +0.0 31.2 66.0 -34.8 DC Re +0.1 +0.0 +5.6

28 23.139k 24.7 +0.0 30.7 66.0 -35.3 DC Re +0.1 +0.0 +5.9

29 21.519k 24.2 +0.0 30.6 66.0 -35.4 DC Re +0.1 +0.0 +6.3

30 15.669k 22.1 +0.0 30.4 66.0 -35.6 DC Re +0.1 +0.0 +8.2

Page 26: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 26 of 161Report No.: MIL05-043

CECM – Conducted Emissions, Common Mode, DC to 150MHz

Test EquipmentEquipment Manufacturer Model # Serial # Asset # Cal Date Cal DueOscilloscope HP 54615B US35420828 00697 8/31/03 8/31/07

Test ProcedureLine to Chassis Ground: While the EUT was up and running in high noise mode, the TestEngineer connected an oscilloscope from DC Line to chassis ground using 150MHz BW setting.Changed the time scale on the oscilloscope from 1ns/division to 5s/divison and captured thenoise plots.

Return to Chassis Ground: While the EUT was up and running in high noise mode, the TestEngineer connected an oscilloscope from Return Line to chassis ground using 150MHz BWsetting. Changed the time scale on the oscilloscope from 1ns/division to 5s/divison and capturedthe noise plots.

Conducted Emissions, Common Mode

Page 27: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 27 of 161Report No.: MIL05-043

CECMDC Line5s/Div

DC Line200ms/Div

Page 28: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 28 of 161Report No.: MIL05-043

DC Line10ms/Div

DC Line2ms/Div

Page 29: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 29 of 161Report No.: MIL05-043

DC Line100us/Div

DC Line1ns/Div

Page 30: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 30 of 161Report No.: MIL05-043

DC Line5ns/Div

DC Line1ns/Div

Page 31: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 31 of 161Report No.: MIL05-043

DC Return1ns/Div

DC Return5ns/Div

Page 32: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 32 of 161Report No.: MIL05-043

DC Return20ns/Div

DC Return5us/Div

Page 33: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 33 of 161Report No.: MIL05-043

DC Return200us/Div

DC Return5ms/Div

Page 34: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 34 of 161Report No.: MIL05-043

DC Return50ms/Div

DC Return1s/Div

Page 35: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 35 of 161Report No.: MIL05-043

DC Return5s/Div

Page 36: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 36 of 161Report No.: MIL05-043

RE101 - Radiated Emissions, Magnetic Field, 30Hz to 100kHz

Test EquipmentFunction Asset # S/N Cal Date Cal DueSA - E4446A 02668 US44300408 01/13/2005 01/13/2007Sig Gen - 2022D 00727 119190-018 11/15/2004 11/15/2006Cable P05309 None 08/01/2005 08/01/2007Cable RG214/U 02410 None 06/07/2004 06/07/2006Andrew Cable- CNT-195 01189 None 04/12/2004 04/12/2006Magnetic Loop Sensor - 7334-1 00170 170 03/04/2005 03/04/2007

Test ProcedureA signal generator was connected into the measurement system. The test engineer performed apath loss check by injecting a signal at 50kHz that was 6dB below the limit line and measuringthe resulting emission on the spectrum analyzer. Then, the signal generator was removed and thetest cable was connected from the loop sensor to the spectrum analyzer.

The UUT was powered up in standard operating mode. The loop was placed 7cm from the frontside of the UUT chassis and a scan was performed. Then, the loop was placed 7cm from thebackside of the UUT and the scan was repeated. Full scans were also performed on the top, leftand right sides of the UUT.

Page 37: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 37 of 161Report No.: MIL05-043

RE101 Radiated Emissions, Magnetic Field Path Check

RE101 Radiated Emissions, Magnetic Field Test Setup

Page 38: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 38 of 161Report No.: MIL05-043

Seq. # Test Description Test Lead or Location / Conditions0 Radiated Emissions Path Check @ 50kHz22 Radiated Emissions Back Side – Connectors / Power Cable is grounded to copper

table as it exits cage and to chamber wall before coming intochamber.

23 Radiated Emissions Left Side / Power Cable is grounded to copper table as it exitscage and to chamber wall before coming into chamber.

24 Radiated Emissions Front Side / Power Cable is grounded to copper table as it exitscage and to chamber wall before coming into chamber.

25 Radiated Emissions Right Side / Power Cable is grounded to copper table as it exitscage and to chamber wall before coming into chamber.

26 Radiated Emissions Top Side / Power Cable is grounded to copper table as it exitscage and to chamber wall before coming into chamber.

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE101 Test LimitWork Order #: 82840 Date: 10/21/2005Test Type: Radiated Scan Time: 1:15:23 PMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 50KHz. 52 (spec limit) - 6dB - 27.5 (Antenna Factor) = 18.5dBuV signal level.

Transducer Legend:T1=3.5' Cable AN 01189T3=Cable 2410

T2=Cable P05309T4=Loop Sensor 7334-1 dBpT

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBpt dBpt dB Ant 1 45.957k 19.6 +0.0 47.5 52.7 -5.2 None +0.0 +0.1 +0.1 +27.7

2 40.471k 15.1 +0.0 43.1 53.8 -10.7 None +0.0 +0.0 +0.1 +27.9

3 .060k 18.3 +0.0 93.7 110.4 -16.7 None +0.0 +0.0 +0.0 +75.4

Page 39: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 39 of 161Report No.: MIL05-043

4 .179k 17.0 +0.0 83.7 100.9 -17.2 None +0.0 +0.0 +0.0 +66.7

5 .299k 12.8 +0.0 75.0 96.5 -21.5 None +0.0 +0.0 +0.0 +62.2

6 37.788k 2.8 +0.0 30.9 54.4 -23.5 None +0.0 +0.0 +0.1 +28.0

7 47.839k -0.6 +0.0 27.2 52.4 -25.2 None +0.0 +0.1 +0.1 +27.6

8 35.626k 0.6 +0.0 28.8 54.9 -26.1 None +0.0 +0.0 +0.1 +28.1

9 20.610k 3.6 +0.0 33.5 59.7 -26.2 None +0.0 +0.0 +0.1 +29.8

10 29.139k 1.6 +0.0 30.3 56.7 -26.4 None +0.0 +0.0 +0.1 +28.6

11 32.423k 1.0 +0.0 29.4 55.8 -26.4 None +0.0 +0.0 +0.1 +28.3

12 33.103k 0.7 +0.0 29.1 55.6 -26.5 None +0.0 +0.0 +0.1 +28.3

13 34.345k 0.5 +0.0 28.8 55.3 -26.5 None +0.0 +0.0 +0.1 +28.2

14 15.965k 4.3 +0.0 35.2 61.9 -26.7 None +0.0 +0.0 +0.1 +30.8

15 23.894k 2.2 +0.0 31.6 58.4 -26.8 None +0.0 +0.0 +0.1 +29.3

16 27.858k 1.3 +0.0 30.2 57.1 -26.9 None +0.0 +0.0 +0.1 +28.8

17 10.159k 4.3 +0.0 37.8 65.9 -28.1 None +0.1 -0.1 +0.1 +33.4

18 .239k 1.2 +0.0 65.4 98.4 -33.0 None +0.0 +0.0 +0.0 +64.2

19 .119k 1.2 +0.0 71.4 104.5 -33.1 None +0.0 +0.0 +0.0 +70.2

20 .420k -0.5 +0.0 58.8 93.5 -34.7 None +0.0 +0.0 +0.0 +59.3

21 1.119k -1.0 +0.0 50.3 85.0 -34.7 None +0.0 +0.0 +0.0 +51.3

22 1.231k -1.0 +0.0 49.5 84.2 -34.7 None +0.0 +0.0 +0.0 +50.5

23 .539k -0.6 +0.0 56.6 91.4 -34.8 None +0.0 +0.0 +0.0 +57.2

24 .112k -1.3 +0.0 69.4 105.0 -35.6 None +0.0 +0.0 +0.0 +70.7

Page 40: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 40 of 161Report No.: MIL05-043

25 3.658k -2.3 +0.0 39.1 74.7 -35.6 None +0.0 +0.0 +0.0 +41.4

26 .359k -1.5 +0.0 59.2 94.9 -35.7 None +0.0 +0.0 +0.0 +60.7

27 .658k -1.7 +0.0 53.9 89.6 -35.7 None +0.0 +0.0 +0.0 +55.6

28 3.082k -2.5 +0.0 40.3 76.2 -35.9 None +0.0 +0.0 +0.0 +42.8

29 3.794k -3.1 +0.0 37.9 74.4 -36.5 None +0.0 +0.0 +0.0 +41.0

30 3.330k -3.3 +0.0 38.9 75.5 -36.6 None +0.0 +0.0 +0.0 +42.2

Page 41: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 41 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE101 Test LimitWork Order #: 82840 Date: 10/21/2005Test Type: Radiated Scan Time: 1:58:11 PMEquipment: Stanford Linear Accelerator Center Sequence#: 22Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508 Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPC Dell DHM JLJJ331Monitor Dell MX-D9J367-47605-379-

AYKJPC65341

Keyboard Dell 04N454 TH-04N454-37171-33F-E488

Mouse Dell by Microsoft X06-08477 noneVME Crate Dawn 11-1011777-2119 002563Power Supply AEMC Instruments AX502 PC70344

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber. Back Side - Connectors

Transducer Legend:T1=3.5' Cable AN 01189T3=Cable 2410

T2=Cable P05309T4=Loop Sensor 7334-1 dBpT

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBpt dBpt dB Ant 1 40.551k 11.6 +0.0 39.6 53.8 -14.2 Magne +0.0 +0.0 +0.1 +27.9

2 .056k 19.7 +0.0 95.7 111.1 -15.4 Magne +0.0 +0.0 +0.0 +76.0

3 47.398k -0.7 +0.0 27.1 52.5 -25.4 Magne +0.0 +0.1 +0.1 +27.6

4 17.687k 4.7 +0.0 35.2 61.0 -25.8 Magne +0.0 +0.0 +0.1 +30.4

5 9.999k 6.4 +0.0 40.0 66.0 -26.0 Magne +0.0 +0.0 +0.1 +33.5

Page 42: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 42 of 161Report No.: MIL05-043

6 14.444k 5.3 +0.0 36.6 62.8 -26.2 Magne +0.0 +0.0 +0.1 +31.2

7 11.681k 5.5 +0.0 38.1 64.6 -26.5 Magne +0.1 -0.1 +0.1 +32.5

8 21.811k 2.8 +0.0 32.5 59.2 -26.7 Magne +0.0 +0.0 +0.1 +29.6

9 26.136k 1.7 +0.0 30.8 57.6 -26.8 Magne +0.0 +0.0 +0.1 +29.0

10 27.778k 1.4 +0.0 30.3 57.1 -26.8 Magne +0.0 +0.0 +0.1 +28.8

11 33.904k 0.3 +0.0 28.6 55.4 -26.8 Magne +0.0 +0.0 +0.1 +28.2

12 31.021k 0.3 +0.0 28.8 56.1 -27.3 Magne +0.0 +0.0 +0.1 +28.4

13 .110k 6.4 +0.0 77.3 105.2 -27.9 Magne +0.0 +0.0 +0.0 +70.9

14 .180k 3.2 +0.0 69.8 100.9 -31.1 Magne +0.0 +0.0 +0.0 +66.6

15 .220k 1.4 +0.0 66.3 99.1 -32.8 Magne +0.0 +0.0 +0.0 +64.9

16 1.792k 0.7 +0.0 48.1 80.9 -32.8 Magne +0.0 +0.0 +0.0 +47.4

17 1.600k 0.2 +0.0 48.5 81.9 -33.4 Magne +0.0 +0.0 +0.0 +48.3

18 .330k 0.7 +0.0 62.1 95.6 -33.5 Magne +0.0 +0.0 +0.0 +61.4

19 1.055k 0.0 +0.0 51.7 85.5 -33.8 Magne +0.0 +0.0 +0.0 +51.7

20 1.456k -0.4 +0.0 48.7 82.7 -34.0 Magne +0.0 +0.0 +0.0 +49.1

21 .299k -0.1 +0.0 62.2 96.5 -34.3 Magne +0.0 +0.0 +0.0 +62.3

22 3.450k -0.9 +0.0 40.9 75.2 -34.3 Magne +0.0 +0.0 +0.0 +41.8

23 1.944k -1.3 +0.0 45.4 80.2 -34.8 Magne +0.0 +0.0 +0.0 +46.7

24 3.346k -1.4 +0.0 40.7 75.5 -34.8 Magne +0.0 +0.0 +0.0 +42.1

25 4.459k -1.7 +0.0 38.0 73.0 -35.0 Magne +0.0 +0.0 +0.0 +39.7

26 1.271k -1.4 +0.0 48.8 83.9 -35.1 Magne +0.0 +0.0 +0.0 +50.2

Page 43: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 43 of 161Report No.: MIL05-043

27 9.387k -2.6 +0.0 31.4 66.5 -35.1 Magne +0.0 +0.0 +0.1 +33.9

28 4.796k -1.8 +0.0 37.2 72.4 -35.2 Magne +0.0 +0.0 +0.0 +39.0

29 8.777k -2.3 +0.0 31.9 67.1 -35.2 Magne +0.0 +0.0 +0.0 +34.2

30 9.203k -2.6 +0.0 31.5 66.7 -35.2 Magne +0.0 +0.0 +0.1 +34.0

Page 44: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 44 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE101 Test LimitWork Order #: 82840 Date: 10/21/2005Test Type: Radiated Scan Time: 2:05:28 PMEquipment: Stanford Linear Accelerator Center Sequence#: 23Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPC Dell DHM JLJJ331Monitor Dell MX-D9J367-47605-379-

AYKJPC65341

Keyboard Dell 04N454 TH-04N454-37171-33F-E488

Mouse Dell by Microsoft X06-08477 noneVME Crate Dawn 11-1011777-2119 002563Power Supply AEMC Instruments AX502 PC70344

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber. Left Side

Transducer Legend:T1=3.5' Cable AN 01189T3=Cable 2410

T2=Cable P05309T4=Loop Sensor 7334-1 dBpT

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBpt dBpt dB Ant 1 40.431k 11.2 +0.0 39.2 53.8 -14.6 Magne +0.0 +0.0 +0.1 +27.9

2 .059k 19.6 +0.0 95.1 110.5 -15.4 Magne +0.0 +0.0 +0.0 +75.5

3 17.367k 6.7 +0.0 37.2 61.2 -24.0 Magne +0.0 +0.0 +0.1 +30.4

4 48.199k -0.6 +0.0 27.2 52.3 -25.1 Magne +0.0 +0.1 +0.1 +27.6

5 37.067k 1.0 +0.0 29.2 54.6 -25.4 Magne +0.0 +0.0 +0.1 +28.1

Page 45: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 45 of 161Report No.: MIL05-043

6 19.449k 4.6 +0.0 34.7 60.2 -25.5 Magne +0.0 +0.0 +0.1 +30.0

7 22.012k 3.7 +0.0 33.4 59.1 -25.7 Magne +0.0 +0.0 +0.1 +29.6

8 34.264k 1.3 +0.0 29.6 55.3 -25.7 Magne +0.0 +0.0 +0.1 +28.2

9 16.366k 5.1 +0.0 35.9 61.7 -25.8 Magne +0.0 +0.0 +0.1 +30.7

10 12.802k 5.5 +0.0 37.6 63.8 -26.2 Magne +0.1 -0.1 +0.1 +32.0

11 25.215k 2.5 +0.0 31.7 57.9 -26.2 Magne +0.0 +0.0 +0.1 +29.1

12 11.400k 5.7 +0.0 38.5 64.8 -26.3 Magne +0.1 -0.1 +0.1 +32.7

13 29.980k 1.5 +0.0 30.1 56.4 -26.3 Magne +0.0 +0.0 +0.1 +28.5

14 35.426k 0.3 +0.0 28.6 55.0 -26.4 Magne +0.0 +0.0 +0.1 +28.2

15 14.724k 4.7 +0.0 35.9 62.6 -26.7 Magne +0.0 +0.0 +0.1 +31.1

16 37.988k -0.5 +0.0 27.6 54.4 -26.8 Magne +0.0 +0.0 +0.1 +28.0

17 18.568k 3.4 +0.0 33.7 60.6 -26.9 Magne +0.0 +0.0 +0.1 +30.2

18 45.116k -2.0 +0.0 25.9 52.9 -27.0 Magne +0.0 +0.1 +0.1 +27.7

19 32.503k 0.2 +0.0 28.6 55.7 -27.1 Magne +0.0 +0.0 +0.1 +28.3

20 43.194k -1.7 +0.0 26.2 53.3 -27.1 Magne +0.0 +0.0 +0.1 +27.8

21 23.373k 1.7 +0.0 31.2 58.6 -27.4 Magne +0.0 +0.0 +0.1 +29.4

22 33.424k -0.3 +0.0 28.1 55.5 -27.4 Magne +0.0 +0.0 +0.1 +28.3

23 36.186k -0.8 +0.0 27.4 54.8 -27.4 Magne +0.0 +0.0 +0.1 +28.1

24 27.177k 0.7 +0.0 29.6 57.3 -27.7 Magne +0.0 +0.0 +0.1 +28.8

25 38.749k -1.6 +0.0 26.5 54.2 -27.7 Magne +0.0 +0.0 +0.1 +28.0

Page 46: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 46 of 161Report No.: MIL05-043

26 49.200k -3.4 +0.0 24.3 52.1 -27.8 Magne +0.0 +0.1 +0.1 +27.5

27 26.216k 0.6 +0.0 29.7 57.6 -27.9 Magne +0.0 +0.0 +0.1 +29.0

28 23.814k 0.1 +0.0 29.5 58.4 -28.9 Magne +0.0 +0.0 +0.1 +29.3

29 .110k 3.4 +0.0 74.3 105.2 -30.9 Magne +0.0 +0.0 +0.0 +70.9

30 2.160k 1.9 +0.0 47.7 79.3 -31.6 Magne +0.0 +0.0 +0.0 +45.8

Page 47: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 47 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE101 Test LimitWork Order #: 82840 Date: 10/21/2005Test Type: Radiated Scan Time: 2:10:44 PMEquipment: Stanford Linear Accelerator Center Sequence#: 24Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPC Dell DHM JLJJ331Monitor Dell MX-D9J367-47605-379-AYKJ PC65341Keyboard Dell 04N454 TH-04N454-37171-33F-E488Mouse Dell by Microsoft X06-08477 noneVME Crate Dawn 11-1011777-2119 002563Power Supply AEMC Instruments AX502 PC70344

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber. Front Side

Transducer Legend:T1=3.5' Cable AN 01189T3=Cable 2410

T2=Cable P05309T4=Loop Sensor 7334-1 dBpT

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBpt dBpt dB Ant 1 40.591k 11.7 +0.0 39.7 53.8 -14.1 Magne +0.0 +0.0 +0.1 +27.9

2 .055k 17.2 +0.0 93.3 111.2 -17.9 Magne +0.0 +0.0 +0.0 +76.1

3 14.524k 6.6 +0.0 37.9 62.7 -24.8 Magne +0.0 +0.0 +0.1 +31.2

4 47.639k -0.8 +0.0 27.0 52.4 -25.4 Magne +0.0 +0.1 +0.1 +27.6

5 48.760k -0.9 +0.0 26.8 52.2 -25.4 Magne +0.0 +0.1 +0.1 +27.5

6 21.972k 3.2 +0.0 32.9 59.1 -26.2 Magne +0.0 +0.0 +0.1 +29.6

Page 48: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 48 of 161Report No.: MIL05-043

7 10.199k 5.7 +0.0 39.2 65.8 -26.6 Magne +0.1 -0.1 +0.1 +33.4

8 29.780k 1.1 +0.0 29.7 56.5 -26.8 Magne +0.0 +0.0 +0.1 +28.5

9 13.483k 4.4 +0.0 36.2 63.4 -27.2 Magne +0.1 -0.1 +0.1 +31.7

10 17.407k 3.5 +0.0 34.0 61.2 -27.2 Magne +0.0 +0.0 +0.1 +30.4

11 24.174k 1.4 +0.0 30.7 58.3 -27.6 Magne +0.0 +0.0 +0.1 +29.2

12 25.535k 0.8 +0.0 30.0 57.8 -27.8 Magne +0.0 +0.0 +0.1 +29.1

13 43.314k -2.6 +0.0 25.3 53.2 -27.9 Magne +0.0 +0.0 +0.1 +27.8

14 .110k 5.9 +0.0 76.8 105.2 -28.4 Magne +0.0 +0.0 +0.0 +70.9

15 33.744k -1.5 +0.0 26.9 55.4 -28.5 Magne +0.0 +0.0 +0.1 +28.3

16 .181k 2.7 +0.0 69.3 100.8 -31.5 Magne +0.0 +0.0 +0.0 +66.6

17 .299k 2.7 +0.0 64.9 96.5 -31.6 Magne +0.0 +0.0 +0.0 +62.2

18 1.552k 1.7 +0.0 50.3 82.2 -31.9 Magne +0.0 +0.0 +0.0 +48.6

19 2.337k 0.8 +0.0 46.0 78.6 -32.6 Magne +0.0 +0.0 +0.0 +45.2

20 1.119k 1.0 +0.0 52.3 85.0 -32.7 Magne +0.0 +0.0 +0.0 +51.3

21 2.921k 0.6 +0.0 43.9 76.7 -32.8 Magne +0.0 +0.0 +0.0 +43.3

22 1.736k 0.3 +0.0 48.0 81.2 -33.2 Magne +0.0 +0.0 +0.0 +47.7

23 3.258k 0.0 +0.0 42.3 75.7 -33.4 Magne +0.0 +0.0 +0.0 +42.3

24 6.934k -0.2 +0.0 35.7 69.2 -33.5 Magne +0.0 +0.0 +0.0 +35.9

25 4.243k -0.3 +0.0 39.8 73.4 -33.6 Magne +0.0 +0.0 +0.0 +40.1

26 .220k 0.5 +0.0 65.4 99.1 -33.7 Magne +0.0 +0.0 +0.0 +64.9

27 .330k 0.5 +0.0 61.9 95.6 -33.7 Magne +0.0 +0.0 +0.0 +61.4

Page 49: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 49 of 161Report No.: MIL05-043

28 1.952k -0.4 +0.0 46.3 80.2 -33.9 Magne +0.0 +0.0 +0.0 +46.7

29 3.458k -0.9 +0.0 40.9 75.2 -34.3 Magne +0.0 +0.0 +0.0 +41.8

30 4.676k -1.5 +0.0 37.7 72.6 -34.9 Magne +0.0 +0.0 +0.0 +39.2

Page 50: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 50 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE101 Test LimitWork Order #: 82840 Date: 10/21/2005Test Type: Radiated Scan Time: 2:13:39 PMEquipment: Stanford Linear Accelerator Center Sequence#: 25Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPC Dell DHM JLJJ331Monitor Dell MX-D9J367-47605-379-AYKJ PC65341Keyboard Dell 04N454 TH-04N454-37171-33F-E488Mouse Dell by Microsoft X06-08477 noneVME Crate Dawn 11-1011777-2119 002563Power Supply AEMC Instruments AX502 PC70344

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber. Right Side

Transducer Legend:T1=3.5' Cable AN 01189T3=Cable 2410

T2=Cable P05309T4=Loop Sensor 7334-1 dBpT

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBpt dBpt dB Ant 1 40.511k 10.4 +0.0 38.4 53.8 -15.4 Magne +0.0 +0.0 +0.1 +27.9

2 .061k 17.5 +0.0 92.8 110.3 -17.5 Magne +0.0 +0.0 +0.0 +75.3

3 .054k 17.5 +0.0 93.8 111.4 -17.6 Magne +0.0 +0.0 +0.0 +76.3

4 44.836k 1.1 +0.0 29.0 52.9 -23.9 Magne +0.0 +0.1 +0.1 +27.7

5 49.921k -0.4 +0.0 27.3 52.0 -24.7 Magne +0.0 +0.1 +0.1 +27.5

6 12.642k 7.0 +0.0 39.2 64.0 -24.8 Magne +0.1 -0.1 +0.1 +32.1

Page 51: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 51 of 161Report No.: MIL05-043

7 46.958k -0.6 +0.0 27.2 52.5 -25.3 Magne +0.0 +0.1 +0.1 +27.6

8 34.264k 1.4 +0.0 29.7 55.3 -25.6 Magne +0.0 +0.0 +0.1 +28.2

9 22.052k 3.6 +0.0 33.3 59.1 -25.8 Magne +0.0 +0.0 +0.1 +29.6

10 48.800k -1.6 +0.0 26.1 52.2 -26.1 Magne +0.0 +0.1 +0.1 +27.5

11 45.717k -1.4 +0.0 26.5 52.8 -26.3 Magne +0.0 +0.1 +0.1 +27.7

12 20.410k 3.3 +0.0 33.2 59.8 -26.6 Magne +0.0 +0.0 +0.1 +29.8

13 21.491k 2.9 +0.0 32.6 59.3 -26.7 Magne +0.0 +0.0 +0.1 +29.6

14 11.441k 5.2 +0.0 38.0 64.8 -26.8 Magne +0.1 -0.1 +0.1 +32.7

15 32.142k 0.4 +0.0 28.9 55.8 -26.9 Magne +0.0 +0.0 +0.1 +28.4

16 17.287k 3.4 +0.0 34.0 61.2 -27.2 Magne +0.0 +0.0 +0.1 +30.5

17 18.648k 2.6 +0.0 32.9 60.6 -27.7 Magne +0.0 +0.0 +0.1 +30.2

18 26.456k 0.5 +0.0 29.5 57.5 -28.0 Magne +0.0 +0.0 +0.1 +28.9

19 24.975k 0.6 +0.0 29.8 58.0 -28.2 Magne +0.0 +0.0 +0.1 +29.1

20 .109k 5.5 +0.0 76.5 105.3 -28.8 Magne +0.0 +0.0 +0.0 +71.0

21 1.079k 3.0 +0.0 54.6 85.3 -30.7 Magne +0.0 +0.0 +0.0 +51.6

22 2.713k 2.4 +0.0 46.3 77.3 -31.0 Magne +0.0 +0.0 +0.0 +43.9

23 .180k 2.8 +0.0 69.4 100.9 -31.5 Magne +0.0 +0.0 +0.0 +66.6

24 .298k 2.5 +0.0 64.8 96.5 -31.7 Magne +0.0 +0.0 +0.0 +62.3

25 1.375k 1.6 +0.0 51.2 83.2 -32.0 Magne +0.0 +0.0 +0.0 +49.6

26 4.860k 1.3 +0.0 40.2 72.3 -32.1 Magne +0.0 +0.0 +0.0 +38.9

27 3.114k 0.4 +0.0 43.1 76.1 -33.0 Magne +0.0 +0.0 +0.0 +42.7

Page 52: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 52 of 161Report No.: MIL05-043

28 2.209k 0.3 +0.0 46.0 79.1 -33.1 Magne +0.0 +0.0 +0.0 +45.7

29 4.523k 0.3 +0.0 39.8 72.9 -33.1 Magne +0.0 +0.0 +0.0 +39.5

30 .218k 0.8 +0.0 65.8 99.2 -33.4 Magne +0.0 +0.0 +0.0 +65.0

Page 53: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 53 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE101 Test LimitWork Order #: 82840 Date: 10/21/2005Test Type: Radiated Scan Time: 2:15:25 PMEquipment: Stanford Linear Accelerator Center Sequence#: 26Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPC Dell DHM JLJJ331Monitor Dell MX-D9J367-47605-379-AYKJ PC65341Keyboard Dell 04N454 TH-04N454-37171-33F-E488Mouse Dell by Microsoft X06-08477 noneVME Crate Dawn 11-1011777-2119 002563Power Supply AEMC Instruments AX502 PC70344

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber. Top Side

Transducer Legend:T1=3.5' Cable AN 01189T3=Cable 2410

T2=Cable P05309T4=Loop Sensor 7334-1 dBpT

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBpt dBpt dB Ant 1 40.551k 11.2 +0.0 39.2 53.8 -14.6 Magne +0.0 +0.0 +0.1 +27.9

2 .054k 19.9 +0.0 96.1 111.3 -15.2 Magne +0.0 +0.0 +0.0 +76.2

3 46.037k -0.4 +0.0 27.4 52.7 -25.3 Magne +0.0 +0.1 +0.1 +27.6

4 47.879k -1.4 +0.0 26.4 52.4 -26.0 Magne +0.0 +0.1 +0.1 +27.6

5 26.136k 2.4 +0.0 31.5 57.6 -26.1 Magne +0.0 +0.0 +0.1 +29.0

6 20.770k 3.5 +0.0 33.4 59.6 -26.2 Magne +0.0 +0.0 +0.1 +29.8

Page 54: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 54 of 161Report No.: MIL05-043

7 12.602k 5.1 +0.0 37.3 64.0 -26.7 Magne +0.1 -0.1 +0.1 +32.1

8 16.686k 4.0 +0.0 34.7 61.5 -26.8 Magne +0.0 +0.0 +0.1 +30.6

9 18.728k 2.9 +0.0 33.1 60.5 -27.4 Magne +0.0 +0.0 +0.1 +30.1

10 24.694k 1.1 +0.0 30.4 58.1 -27.7 Magne +0.0 +0.0 +0.1 +29.2

11 30.460k -0.3 +0.0 28.3 56.3 -28.0 Magne +0.0 +0.0 +0.1 +28.5

12 1.215k 3.9 +0.0 54.5 84.3 -29.8 Magne +0.0 +0.0 +0.0 +50.6

13 .218k 3.9 +0.0 68.9 99.2 -30.3 Magne +0.0 +0.0 +0.0 +65.0

14 1.103k 3.2 +0.0 54.6 85.1 -30.5 Magne +0.0 +0.0 +0.0 +51.4

15 .110k 3.5 +0.0 74.4 105.2 -30.8 Magne +0.0 +0.0 +0.0 +70.9

16 9.306k 0.3 +0.0 34.3 66.6 -32.3 Magne +0.0 +0.0 +0.1 +33.9

17 1.648k 0.9 +0.0 49.0 81.7 -32.7 Magne +0.0 +0.0 +0.0 +48.1

18 4.275k 0.7 +0.0 40.7 73.4 -32.7 Magne +0.0 +0.0 +0.0 +40.0

19 2.289k 0.7 +0.0 46.0 78.8 -32.8 Magne +0.0 +0.0 +0.0 +45.3

20 9.527k -0.3 +0.0 33.6 66.4 -32.8 Magne +0.0 +0.0 +0.1 +33.8

21 2.537k 0.5 +0.0 45.0 77.9 -32.9 Magne +0.0 +0.0 +0.0 +44.5

22 3.394k 0.4 +0.0 42.4 75.4 -33.0 Magne +0.0 +0.0 +0.0 +42.0

23 3.738k 0.3 +0.0 41.5 74.5 -33.0 Magne +0.0 +0.0 +0.0 +41.2

24 1.536k 0.4 +0.0 49.1 82.3 -33.2 Magne +0.0 +0.0 +0.0 +48.7

25 .297k 0.9 +0.0 63.2 96.5 -33.3 Magne +0.0 +0.0 +0.0 +62.3

26 .179k 0.8 +0.0 67.5 100.9 -33.4 Magne +0.0 +0.0 +0.0 +66.7

27 2.008k -0.6 +0.0 45.9 79.9 -34.0 Magne +0.0 +0.0 +0.0 +46.5

Page 55: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 55 of 161Report No.: MIL05-043

28 9.856k -2.1 +0.0 31.6 66.1 -34.5 Magne +0.0 +0.0 +0.1 +33.6

29 3.130k -1.4 +0.0 41.3 76.1 -34.8 Magne +0.0 +0.0 +0.0 +42.7

30 2.665k -2.0 +0.0 42.1 77.5 -35.4 Magne +0.0 +0.0 +0.0 +44.1

Page 56: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 56 of 161Report No.: MIL05-043

RE102 - Radiated Emissions, Electric Field, 10kHz to 18GHz

Test EquipmentFunction Asset # S/N Cal Date Cal DueSA - E4446A 02668 US44300408 01/13/2005 01/13/2007Rod Antenna - 3301B 01579 92073275 01/12/2004 01/12/2006Sig Gen - 2022D 00727 119190-018 11/15/2004 11/15/2006Cable P05309 None 08/01/2005 08/01/2007Cable RG214/U 02410 None 06/07/2004 06/07/2006Andrew Cable- CNT-195 01189 None 04/12/2004 04/12/2006Bicon Antenna EMCO3104 00732 2683 04/11/2005 04/11/2007Horn - SAS 570 02525 155 part # 2490 06/10/2005 06/10/2007HF Pre Amp- 00785 3123A00283 05/09/2005 05/09/2007Cable, 72" 2.92mm 40 GHz P05317 None 07/12/2005 07/12/2007Horn Antenna 3115 02113 9606-4660 03/08/2005 03/08/2007HF Cable - PE35591-60 02716 None 08/09/2005 08/09/2007

Test ProcedureThe signal generator was connected to the rod antenna through the calibration fixture. The testengineer injected a signal at 2MHz that was 6dB below the limit line and measured the resultingemission on the spectrum analyzer. The check was repeated at 15MHz and 30MHz. Then, thesignal generator was removed and the antenna element was connected to the antenna and theantenna output was connected to the measurement system.

The UUT was powered up in standard operating mode. The rod antenna was placed one meter infront of the UUT. The EMITest™ software automatically scanned from 10kHz to 30MHz usingthe sweep rates required by the Test Procedure. The biconical antenna was placed one meter infront of the UUT and was connected to the measurement system. The test engineer removedperformed a path loss check at 200MHz. The EMITest™ software automatically scanned from30MHz to 200MHz in horizontal and vertical antenna polarizations using the sweep ratesrequired by the Test Procedure. The double ridge guide horn antenna was connected into thesetup and placed one meter from the UUT setup. The test engineer performed a path loss checkat 1GHz. The EMITest™ software automatically scanned from 200MHz to 1GHz in horizontaland vertical antenna polarizations using the sweep rates required by the Test Procedure. Then,the high frequency double ridge guide horn antenna was installed and placed one meter from theUUT setup. The antenna was then connected to the measurement system. The test engineerperformed a path loss check at 18GHz. The EMITest™ software automatically scanned from1GHz to 18GHz in horizontal and vertical antenna polarizations using the sweep rates requiredby the Test Procedure with the exception of 1.55 – 1.6 / Vertical, 1kHz RBW, where 1kHz RBWwas used per Fred (Witness).

Page 57: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 57 of 161Report No.: MIL05-043

Rod Antenna, 10kHz - 30MHz Path Check

Rod Antenna, 10kHz - 30MHz Test Setup

Page 58: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 58 of 161Report No.: MIL05-043

Bicon Antenna and Log Periodic Antenna Path Check

Bicon Antenna, 30 - 200MHz Vertical Polarization Test Setup

Page 59: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 59 of 161Report No.: MIL05-043

Horn Antenna, 200 - 1000MHz Vertical Polarization Test Setup

Horn Antenna, 200 - 1000MHz Vertical Polarization Closeup

Page 60: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 60 of 161Report No.: MIL05-043

RE102 Path Check for High Frequency Horn Antenna

Horn Antenna, 8 - 18GHz Vertical Polarization Test Setup

Page 61: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 61 of 161Report No.: MIL05-043

RE102, 1 - 18GHz Solution for Sequence 19

Data SheetsSeq. # Test Description Frequency / Polarity0 Radiated Emissions 10kHz Path Check0 Radiated Emissions 15MHz Path Check0 Radiated Emissions 30MHz Path Check1 Radiated Emissions 10kHz – 30MHz / Vertical3 Radiated Emissions 30 – 200MHz / Horizontal2 Radiated Emissions 30 – 200MHz / Vertical0 Radiated Emissions 200MHz Path Check0 Radiated Emissions 1000MHz Path Check5 Radiated Emissions 200 – 1000MHz / Horizontal4 Radiated Emissions 200 – 1000MHz / Vertical11 Radiated Emissions 1 – 1.55GHz / Horizontal6 Radiated Emissions 1 – 1.55GHz / Vertical15 Radiated Emissions 1.55 – 1.6 / Horizontal19 Radiated Emissions 1.55 – 1.6 / Vertical, 1kHz RBW12 Radiated Emissions 1.6 – 1.77GHz / Horizontal7 Radiated Emissions 1.6 – 1.77GHz / Vertical14 Radiated Emissions 1.77 – 2.3GHz / Horizontal10 Radiated Emissions 1.77 – 2.3GHz / Vertical0 Radiated Emissions 18GHz Path Check13 Radiated Emissions 2.3 – 18GHz / Horizontal8 Radiated Emissions 2.3 – 18GHz / Vertical

Page 62: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 62 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 82840 Date: 10/19/2005Test Type: Radiated Scan Time: 1:06:22 PMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 10KHz. 90 (spec limit) - 6dB - 4.2 (Antenna Factor) = 79.8dBuV signal level.

Transducer Legend:T1=AN 01579 Rod AntennaT3=Cable P05309

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 10.000k 80.8 +0.0 85.1 90.0 -4.9 None +4.2 +0.1 -0.1 +0.1

2 91.877k 25.9 +0.0 30.0 90.0 -60.0 None +4.0 +0.0 +0.0 +0.1

3 28.388k 25.0 +0.0 29.1 90.0 -60.9 None +4.0 +0.0 +0.0 +0.1

4 30.938k 22.3 +0.0 26.4 90.0 -63.6 None +4.0 +0.0 +0.0 +0.1

5 51.475k 22.1 +0.0 26.3 90.0 -63.7 None +4.0 +0.0 +0.1 +0.1

6 36.576k 21.7 +0.0 25.8 90.0 -64.2 None +4.0 +0.0 +0.0 +0.1

7 54.025k 21.5 +0.0 25.7 90.0 -64.3 None +4.0 +0.0 +0.1 +0.1

8 41.408k 21.5 +0.0 25.6 90.0 -64.4 None +4.0 +0.0 +0.0 +0.1

9 43.556k 21.0 +0.0 25.1 90.0 -64.9 None +4.0 +0.0 +0.0 +0.1

10 48.925k 20.9 +0.0 25.1 90.0 -64.9 None +4.0 +0.0 +0.1 +0.1

Page 63: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 63 of 161Report No.: MIL05-043

11 40.603k 20.7 +0.0 24.8 90.0 -65.2 None +4.0 +0.0 +0.0 +0.1

12 46.374k 20.6 +0.0 24.8 90.0 -65.2 None +4.0 +0.0 +0.1 +0.1

13 56.710k 20.8 +0.0 24.8 90.0 -65.2 None +4.0 +0.0 +0.0 +0.0

14 58.455k 20.7 +0.0 24.7 90.0 -65.3 None +4.0 +0.0 +0.0 +0.0

15 49.730k 20.3 +0.0 24.5 90.0 -65.5 None +4.0 +0.0 +0.1 +0.1

16 60.468k 20.4 +0.0 24.4 90.0 -65.6 None +4.0 +0.0 +0.0 +0.0

17 69.058k 19.8 +0.0 23.9 90.0 -66.1 None +4.0 +0.0 +0.0 +0.1

18 225.849k 19.8 +0.0 23.8 90.0 -66.2 None +4.0 +0.0 +0.0 +0.0

19 55.904k 19.7 +0.0 23.7 90.0 -66.3 None +4.0 +0.0 +0.0 +0.0

20 59.528k 19.6 +0.0 23.6 90.0 -66.4 None +4.0 +0.0 +0.0 +0.0

21 66.508k 19.2 +0.0 23.3 90.0 -66.7 None +4.0 +0.0 +0.0 +0.1

22 54.294k 19.0 +0.0 23.2 90.0 -66.8 None +4.0 +0.0 +0.1 +0.1

23 429.349k 18.6 +0.0 22.8 90.0 -67.2 None +4.1 +0.0 +0.1 +0.0

24 67.314k 18.5 +0.0 22.6 90.0 -67.4 None +4.0 +0.0 +0.0 +0.1

25 70.266k 18.5 +0.0 22.6 90.0 -67.4 None +4.0 +0.0 +0.0 +0.1

26 77.917k 18.3 +0.0 22.4 90.0 -67.6 None +4.1 +0.0 +0.0 +0.0

27 110.266k 18.4 +0.0 22.4 90.0 -67.6 None +4.0 +0.0 +0.0 +0.0

Page 64: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 64 of 161Report No.: MIL05-043

28 79.394k 18.2 +0.0 22.3 90.0 -67.7 None +4.1 +0.0 +0.0 +0.0

29 305.399k 18.3 +0.0 22.3 90.0 -67.7 None +3.9 +0.0 +0.1 +0.0

30 101.004k 17.9 +0.0 21.9 90.0 -68.1 None +4.0 +0.0 +0.0 +0.0

Page 65: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 65 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 82840 Date: 10/19/2005Test Type: Radiated Scan Time: 1:19:28 PMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 15.005MHz. 90 (spec limit) - 6dB - 6.9 (Antenna Factor) = 77.1dBuV signal level.

Transducer Legend:T1=AN 01579 Rod AntennaT3=Cable P05309

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 15.005M 78.0 +0.0 85.4 90.0 -4.6 None +6.9 +0.1 +0.2 +0.2

2 10.536k 23.2 +0.0 27.5 90.0 -62.5 None +4.2 +0.1 -0.1 +0.1

3 11.341k 21.7 +0.0 26.0 90.0 -64.0 None +4.2 +0.1 -0.1 +0.1

4 12.549k 21.4 +0.0 25.6 90.0 -64.4 None +4.1 +0.1 -0.1 +0.1

5 13.086k 21.1 +0.0 25.3 90.0 -64.7 None +4.1 +0.1 -0.1 +0.1

6 13.892k 20.4 +0.0 24.6 90.0 -65.4 None +4.1 +0.1 -0.1 +0.1

7 14.294k 20.2 +0.0 24.4 90.0 -65.6 None +4.1 +0.0 +0.0 +0.1

8 16.710k 19.2 +0.0 23.4 90.0 -66.6 None +4.1 +0.0 +0.0 +0.1

9 149.999k 19.3 +0.0 23.3 90.0 -66.7 None +4.0 +0.0 +0.0 +0.0

10 179.599k 18.9 +0.0 22.9 90.0 -67.1 None +4.0 +0.0 +0.0 +0.0

Page 66: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 66 of 161Report No.: MIL05-043

11 17.247k 18.7 +0.0 22.8 90.0 -67.2 None +4.0 +0.0 +0.0 +0.1

12 166.649k 18.7 +0.0 22.7 90.0 -67.3 None +4.0 +0.0 +0.0 +0.0

13 153.699k 18.5 +0.0 22.5 90.0 -67.5 None +4.0 +0.0 +0.0 +0.0

14 41.005k 18.1 +0.0 22.2 90.0 -67.8 None +4.0 +0.0 +0.0 +0.1

15 172.199k 18.0 +0.0 22.0 90.0 -68.0 None +4.0 +0.0 +0.0 +0.0

16 211.049k 17.9 +0.0 21.9 90.0 -68.1 None +4.0 +0.0 +0.0 +0.0

17 22.079k 17.6 +0.0 21.7 90.0 -68.3 None +4.0 +0.0 +0.0 +0.1

18 19.395k 17.4 +0.0 21.5 90.0 -68.5 None +4.0 +0.0 +0.0 +0.1

19 220.299k 16.9 +0.0 20.9 90.0 -69.1 None +4.0 +0.0 +0.0 +0.0

20 216.599k 16.5 +0.0 20.5 90.0 -69.5 None +4.0 +0.0 +0.0 +0.0

21 1.168M 15.8 +0.0 20.1 90.0 -69.9 None +4.2 +0.0 +0.0 +0.1

22 24.227k 15.9 +0.0 20.0 90.0 -70.0 None +4.0 +0.0 +0.0 +0.1

23 23.690k 15.7 +0.0 19.8 90.0 -70.2 None +4.0 +0.0 +0.0 +0.1

24 29.793M 7.9 +0.0 19.2 90.0 -70.8 None +10.8 +0.1 +0.1 +0.3

25 29.864k 14.9 +0.0 19.0 90.0 -71.0 None +4.0 +0.0 +0.0 +0.1

26 25.972k 14.8 +0.0 18.9 90.0 -71.1 None +4.0 +0.0 +0.0 +0.1

27 26.784M 8.2 +0.0 18.9 90.0 -71.1 None +10.0 +0.2 +0.2 +0.3

Page 67: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 67 of 161Report No.: MIL05-043

28 27.985k 14.7 +0.0 18.8 90.0 -71.2 None +4.0 +0.0 +0.0 +0.1

29 29.673M 7.5 +0.0 18.8 90.0 -71.2 None +10.8 +0.1 +0.1 +0.3

30 29.880M 7.2 +0.0 18.6 90.0 -71.4 None +10.9 +0.1 +0.1 +0.3

Page 68: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 68 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 82840 Date: 10/19/2005Test Type: Radiated Scan Time: 1:25:18 PMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 30.00MHz. 90 (spec limit) - 6dB - 10.9 (Antenna Factor) = 73.1dBuV signal level.

Transducer Legend:T1=AN 01579 Rod AntennaT3=Cable P05309

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 30.000M 70.7 +0.0 82.1 90.0 -7.9 None +10.9 +0.1 +0.1 +0.3

2 10.133k 25.6 +0.0 29.9 90.0 -60.1 None +4.2 +0.1 -0.1 +0.1

3 11.744k 25.0 +0.0 29.3 90.0 -60.7 None +4.2 +0.1 -0.1 +0.1

4 15.234k 23.0 +0.0 27.2 90.0 -62.8 None +4.1 +0.0 +0.0 +0.1

5 15.771k 22.2 +0.0 26.4 90.0 -63.6 None +4.1 +0.0 +0.0 +0.1

6 29.697M 14.8 +0.0 26.1 90.0 -63.9 None +10.8 +0.1 +0.1 +0.3

7 14.294k 20.6 +0.0 24.8 90.0 -65.2 None +4.1 +0.0 +0.0 +0.1

8 153.699k 19.9 +0.0 23.9 90.0 -66.1 None +4.0 +0.0 +0.0 +0.0

9 14.026k 19.3 +0.0 23.5 90.0 -66.5 None +4.1 +0.1 -0.1 +0.1

10 14.831k 19.3 +0.0 23.5 90.0 -66.5 None +4.1 +0.0 +0.0 +0.1

Page 69: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 69 of 161Report No.: MIL05-043

11 40.737k 19.0 +0.0 23.1 90.0 -66.9 None +4.0 +0.0 +0.0 +0.1

12 16.173k 18.7 +0.0 22.9 90.0 -67.1 None +4.1 +0.0 +0.0 +0.1

13 179.599k 16.7 +0.0 20.7 90.0 -69.3 None +4.0 +0.0 +0.0 +0.0

14 185.149k 16.7 +0.0 20.7 90.0 -69.3 None +4.0 +0.0 +0.0 +0.0

15 201.799k 16.7 +0.0 20.7 90.0 -69.3 None +4.0 +0.0 +0.0 +0.0

16 29.462k 16.2 +0.0 20.3 90.0 -69.7 None +4.0 +0.0 +0.0 +0.1

17 22.616k 16.0 +0.0 20.1 90.0 -69.9 None +4.0 +0.0 +0.0 +0.1

18 29.601M 8.5 +0.0 19.8 90.0 -70.2 None +10.8 +0.1 +0.1 +0.3

19 23.422k 15.4 +0.0 19.5 90.0 -70.5 None +4.0 +0.0 +0.0 +0.1

20 23.824k 15.3 +0.0 19.4 90.0 -70.6 None +4.0 +0.0 +0.0 +0.1

21 22.722M 9.5 +0.0 19.1 90.0 -70.9 None +8.9 +0.2 +0.2 +0.3

22 29.505M 7.8 +0.0 19.1 90.0 -70.9 None +10.8 +0.1 +0.1 +0.3

23 24.262M 8.8 +0.0 18.8 90.0 -71.2 None +9.3 +0.2 +0.2 +0.3

24 33.086k 14.6 +0.0 18.7 90.0 -71.3 None +4.0 +0.0 +0.0 +0.1

25 28.580M 7.7 +0.0 18.7 90.0 -71.3 None +10.5 +0.1 +0.1 +0.3

26 1.160M 14.3 +0.0 18.6 90.0 -71.4 None +4.2 +0.0 +0.0 +0.1

27 28.412M 7.7 +0.0 18.6 90.0 -71.4 None +10.4 +0.1 +0.1 +0.3

Page 70: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 70 of 161Report No.: MIL05-043

28 27.391M 7.8 +0.0 18.5 90.0 -71.5 None +10.2 +0.1 +0.1 +0.3

29 36.039k 14.3 +0.0 18.4 90.0 -71.6 None +4.0 +0.0 +0.0 +0.1

30 366.449k 14.3 +0.0 18.4 90.0 -71.6 None +4.0 +0.0 +0.1 +0.0

Page 71: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 71 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/19/2005Test Type: Radiated Scan Time: 1:56:49 PMEquipment: Stanford Linear Accelerator Center Sequence#: 1Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=AN 01579 Rod AntennaT3=Cable P05309

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 23.233M 28.3 +0.0 38.0 90.0 -52.0 Rod A +9.0 +0.2 +0.2 +0.3

2 14.022M 29.0 +0.0 36.1 90.0 -53.9 Rod A +6.6 +0.1 +0.2 +0.2

3 17.976M 25.9 +0.0 34.1 90.0 -55.9 Rod A +7.7 +0.1 +0.1 +0.3

4 13.972M 26.8 +0.0 33.9 90.0 -56.1 Rod A +6.6 +0.1 +0.2 +0.2

5 18.026M 25.6 +0.0 33.8 90.0 -56.2 Rod A +7.7 +0.1 +0.1 +0.3

6 19.978M 24.8 +0.0 33.4 90.0 -56.6 Rod A +8.1 +0.1 +0.1 +0.3

Page 72: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 72 of 161Report No.: MIL05-043

7 10.670k 28.6 +0.0 32.9 90.0 -57.1 Rod A +4.2 +0.1 -0.1 +0.1

8 20.028M 24.1 +0.0 32.7 90.0 -57.3 Rod A +8.1 +0.1 +0.1 +0.3

9 23.991M 22.6 +0.0 32.5 90.0 -57.5 Rod A +9.2 +0.2 +0.2 +0.3

10 22.994M 22.6 +0.0 32.3 90.0 -57.7 Rod A +9.0 +0.2 +0.2 +0.3

11 24.023M 22.2 +0.0 32.1 90.0 -57.9 Rod A +9.2 +0.2 +0.2 +0.3

12 15.974M 23.9 +0.0 31.6 90.0 -58.4 Rod A +7.2 +0.1 +0.2 +0.2

13 19.998M 22.7 +0.0 31.3 90.0 -58.7 Rod A +8.1 +0.1 +0.1 +0.3

14 16.024M 23.4 +0.0 31.1 90.0 -58.9 Rod A +7.2 +0.1 +0.2 +0.2

15 12.549k 26.5 +0.0 30.7 90.0 -59.3 Rod A +4.1 +0.1 -0.1 +0.1

16 17.175M 22.7 +0.0 30.7 90.0 -59.3 Rod A +7.5 +0.1 +0.2 +0.2

17 13.892k 26.2 +0.0 30.4 90.0 -59.6 Rod A +4.1 +0.1 -0.1 +0.1

18 1.168M 26.1 +0.0 30.4 90.0 -59.6 Rod A +4.2 +0.0 +0.0 +0.1

19 15.544M 22.8 +0.0 30.4 90.0 -59.6 Rod A +7.1 +0.1 +0.2 +0.2

20 1.587M 25.4 +0.0 29.9 90.0 -60.1 Rod A +4.3 +0.1 +0.0 +0.1

21 15.203M 22.2 +0.0 29.7 90.0 -60.3 Rod A +7.0 +0.1 +0.2 +0.2

22 16.965M 21.6 +0.0 29.5 90.0 -60.5 Rod A +7.4 +0.1 +0.2 +0.2

23 18.176M 21.2 +0.0 29.4 90.0 -60.6 Rod A +7.7 +0.1 +0.1 +0.3

24 15.771k 25.0 +0.0 29.2 90.0 -60.8 Rod A +4.1 +0.0 +0.0 +0.1

25 816.000k 25.2 +0.0 29.2 90.0 -60.8 Rod A +4.0 +0.0 +0.0 +0.0

26 16.174M 21.4 +0.0 29.1 90.0 -60.9 Rod A +7.2 +0.1 +0.2 +0.2

27 1.519M 24.4 +0.0 28.9 90.0 -61.1 Rod A +4.3 +0.1 +0.0 +0.1

Page 73: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 73 of 161Report No.: MIL05-043

28 1.351M 24.5 +0.0 28.8 90.0 -61.2 Rod A +4.2 +0.0 +0.0 +0.1

29 21.980M 19.6 +0.0 28.8 90.0 -61.2 Rod A +8.7 +0.1 +0.1 +0.3

30 24.997M 18.5 +0.0 28.7 90.0 -61.3 Rod A +9.5 +0.2 +0.2 +0.3

Page 74: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 74 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/19/2005Test Type: Radiated Scan Time: 2:42:38 PMEquipment: Stanford Linear Accelerator Center Sequence#: 3Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=8447D OPT 010 AN00686 SN 2944A08591T3=Cable P05309T5=Bicon AN732 4-11-05

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1

T5T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 95.994M 51.0 +0.0 36.3 90.0 -53.7 Horiz -29.2

+13.4 +0.2 +0.2 +0.7

2 132.019M 49.6 +0.0 34.5 90.0 -55.5 Horiz -29.1 +12.7

+0.2 +0.3 +0.8

3 133.342M 49.1 +0.0 34.0 90.0 -56.0 Horiz -29.1 +12.7

+0.2 +0.3 +0.8

4 199.976M 43.5 +0.0 32.0 90.0 -58.0 Horiz -28.8 +15.8

+0.2 +0.3 +1.0

5 98.999M 46.4 +0.0 30.6 90.0 -59.4 Horiz -29.3 +12.3

+0.2 +0.2 +0.8

Page 75: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 75 of 161Report No.: MIL05-043

6 192.018M 36.9 +0.0 25.6 90.0 -64.4 Horiz -28.9 +16.0

+0.2 +0.3 +1.1

7 59.987M 42.8 +0.0 25.0 90.0 -65.0 Horiz -29.3 +10.7

+0.1 +0.2 +0.5

8 181.504M 35.6 +0.0 24.6 90.0 -65.4 Horiz -28.9 +16.3

+0.3 +0.3 +1.0

9 113.143M 40.0 +0.0 24.3 90.0 -65.7 Horiz -29.2 +12.3

+0.2 +0.3 +0.7

10 134.313M 39.3 +0.0 24.3 90.0 -65.7 Horiz -29.1 +12.8

+0.2 +0.3 +0.8

11 87.025M 39.0 +0.0 23.6 90.0 -66.4 Horiz -29.3 +12.9

+0.2 +0.2 +0.6

12 88.027M 37.8 +0.0 23.4 90.0 -66.6 Horiz -29.3 +13.8

+0.2 +0.2 +0.7

13 94.993M 37.8 +0.0 23.4 90.0 -66.6 Horiz -29.2 +13.7

+0.2 +0.2 +0.7

14 178.857M 33.7 +0.0 22.8 90.0 -67.2 Horiz -28.9 +16.4

+0.3 +0.3 +1.0

15 179.916M 33.0 +0.0 22.1 90.0 -67.9 Horiz -28.9 +16.4

+0.3 +0.3 +1.0

16 140.046M 37.0 +0.0 21.9 90.0 -68.1 Horiz -29.1 +12.8

+0.2 +0.2 +0.8

17 88.462M 35.5 +0.0 21.5 90.0 -68.5 Horiz -29.3 +14.2

+0.2 +0.2 +0.7

18 135.989M 36.6 +0.0 21.5 90.0 -68.5 Horiz -29.1 +12.8

+0.2 +0.2 +0.8

19 111.996M 36.7 +0.0 21.0 90.0 -69.0 Horiz -29.2 +12.3

+0.2 +0.3 +0.7

20 140.399M 35.8 +0.0 20.8 90.0 -69.2 Horiz -29.1 +12.9

+0.2 +0.2 +0.8

21 176.035M 31.5 +0.0 20.7 90.0 -69.3 Horiz -28.9 +16.5

+0.3 +0.3 +1.0

22 178.152M 31.2 +0.0 20.3 90.0 -69.7 Horiz -28.9 +16.4

+0.3 +0.3 +1.0

23 197.972M 31.6 +0.0 20.2 90.0 -69.8 Horiz -28.8 +15.9

+0.2 +0.3 +1.0

24 178.416M 30.9 +0.0 20.0 90.0 -70.0 Horiz -28.9 +16.4

+0.3 +0.3 +1.0

25 66.692M 39.5 +0.0 19.8 90.0 -70.2 Horiz -29.3 +8.7

+0.2 +0.2 +0.5

26 120.023M 34.8 +0.0 19.5 90.0 -70.5 Horiz -29.1 +12.5

+0.2 +0.3 +0.8

27 144.015M 34.5 +0.0 19.5 90.0 -70.5 Horiz -29.1 +12.9

+0.2 +0.2 +0.8

Page 76: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 76 of 161Report No.: MIL05-043

28 140.575M 34.2 +0.0 19.2 90.0 -70.8 Horiz -29.1 +12.9

+0.2 +0.2 +0.8

29 105.998M 34.9 +0.0 19.1 90.0 -70.9 Horiz -29.2 +12.2

+0.2 +0.3 +0.7

30 160.069M 32.0 +0.0 18.8 90.0 -71.2 Horiz -29.0 +14.5

+0.2 +0.3 +0.8

Page 77: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 77 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/19/2005Test Type: Radiated Scan Time: 2:38:59 PMEquipment: Stanford Linear Accelerator Center Sequence#: 2Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=8447D OPT 010 AN00686 SN 2944A08591T3=Cable P05309T5=Bicon AN732 4-11-05

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1

T5T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 95.994M 50.0 +0.0 35.3 90.0 -54.7 Vert -29.2

+13.4 +0.2 +0.2 +0.7

2 98.999M 50.0 +0.0 34.2 90.0 -55.8 Vert -29.3 +12.3

+0.2 +0.2 +0.8

3 132.019M 46.9 +0.0 31.8 90.0 -58.2 Vert -29.1 +12.7

+0.2 +0.3 +0.8

4 40.028M 48.4 +0.0 30.5 90.0 -59.5 Vert -29.4 +10.6

+0.2 +0.2 +0.5

5 199.976M 41.2 +0.0 29.7 90.0 -60.3 Vert -28.8 +15.8

+0.2 +0.3 +1.0

Page 78: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 78 of 161Report No.: MIL05-043

6 32.990M 45.6 +0.0 29.1 90.0 -60.9 Vert -29.4 +12.2

+0.2 +0.1 +0.4

7 41.457M 45.9 +0.0 28.1 90.0 -61.9 Vert -29.4 +10.7

+0.2 +0.2 +0.5

8 40.399M 45.9 +0.0 28.0 90.0 -62.0 Vert -29.4 +10.6

+0.2 +0.2 +0.5

9 36.059M 43.4 +0.0 26.1 90.0 -63.9 Vert -29.4 +11.3

+0.3 +0.1 +0.4

10 159.981M 38.9 +0.0 25.7 90.0 -64.3 Vert -29.0 +14.5

+0.2 +0.3 +0.8

11 181.504M 36.7 +0.0 25.7 90.0 -64.3 Vert -28.9 +16.3

+0.3 +0.3 +1.0

12 180.004M 36.3 +0.0 25.4 90.0 -64.6 Vert -28.9 +16.4

+0.3 +0.3 +1.0

13 144.015M 39.8 +0.0 24.8 90.0 -65.2 Vert -29.1 +12.9

+0.2 +0.2 +0.8

14 120.023M 39.5 +0.0 24.2 90.0 -65.8 Vert -29.1 +12.5

+0.2 +0.3 +0.8

15 191.995M 34.4 +0.0 23.1 90.0 -66.9 Vert -28.9 +16.0

+0.2 +0.3 +1.1

16 177.799M 33.4 +0.0 22.5 90.0 -67.5 Vert -28.9 +16.4

+0.3 +0.3 +1.0

17 181.768M 33.3 +0.0 22.3 90.0 -67.7 Vert -28.9 +16.3

+0.3 +0.3 +1.0

18 178.857M 32.7 +0.0 21.8 90.0 -68.2 Vert -28.9 +16.4

+0.3 +0.3 +1.0

19 34.048M 38.1 +0.0 21.3 90.0 -68.7 Vert -29.4 +11.8

+0.3 +0.1 +0.4

20 60.030M 39.0 +0.0 21.2 90.0 -68.8 Vert -29.3 +10.7

+0.1 +0.2 +0.5

21 95.515M 35.5 +0.0 20.9 90.0 -69.1 Vert -29.2 +13.5

+0.2 +0.2 +0.7

22 178.240M 31.8 +0.0 20.9 90.0 -69.1 Vert -28.9 +16.4

+0.3 +0.3 +1.0

23 100.000M 36.8 +0.0 20.7 90.0 -69.3 Vert -29.3 +12.0

+0.2 +0.2 +0.8

24 175.946M 31.2 +0.0 20.4 90.0 -69.6 Vert -28.9 +16.5

+0.3 +0.3 +1.0

25 94.949M 34.7 +0.0 20.3 90.0 -69.7 Vert -29.2 +13.7

+0.2 +0.2 +0.7

26 114.025M 35.7 +0.0 20.1 90.0 -69.9 Vert -29.2 +12.4

+0.2 +0.3 +0.7

Page 79: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 79 of 161Report No.: MIL05-043

27 99.956M 36.0 +0.0 19.9 90.0 -70.1 Vert -29.3 +12.0

+0.2 +0.2 +0.8

28 177.181M 30.8 +0.0 19.9 90.0 -70.1 Vert -28.9 +16.4

+0.3 +0.3 +1.0

29 140.487M 34.6 +0.0 19.6 90.0 -70.4 Vert -29.1 +12.9

+0.2 +0.2 +0.8

30 133.254M 34.4 +0.0 19.3 90.0 -70.7 Vert -29.1 +12.7

+0.2 +0.3 +0.8

Page 80: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 80 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 82840 Date: 10/19/2005Test Type: Radiated Scan Time: 1:37:48 PMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 200.00MHz. 90 (spec limit) - 6dB - 15.8 (Antenna Factor) = 68.2dBuV signal level.

Transducer Legend:T1=8447D OPT 010 AN00686 SN 2944A08591T3=Cable P05309T5=Bicon AN732 4-11-05

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1

T5T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 199.976M 94.8 +0.0 83.3 90.0 -6.7 None -28.8

+15.8 +0.2 +0.3 +1.0

2 199.670M 31.0 +0.0 19.5 90.0 -70.5 None -28.8 +15.8

+0.2 +0.3 +1.0

3 188.210M 28.9 +0.0 17.7 90.0 -72.3 None -28.9 +16.1

+0.2 +0.3 +1.1

4 186.002M 28.5 +0.0 17.5 90.0 -72.5 None -28.9 +16.2

+0.3 +0.3 +1.1

5 189.354M 28.7 +0.0 17.5 90.0 -72.5 None -28.9 +16.1

+0.2 +0.3 +1.1

6 188.207M 28.6 +0.0 17.4 90.0 -72.6 None -28.9 +16.1

+0.2 +0.3 +1.1

7 188.208M 28.4 +0.0 17.2 90.0 -72.8 None -28.9 +16.1

+0.2 +0.3 +1.1

8 188.210M 28.4 +0.0 17.2 90.0 -72.8 None -28.9 +16.1

+0.2 +0.3 +1.1

9 193.209M 28.4 +0.0 17.1 90.0 -72.9 None -28.9 +16.0

+0.2 +0.3 +1.1

Page 81: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 81 of 161Report No.: MIL05-043

10 178.945M 27.9 +0.0 17.0 90.0 -73.0 None -28.9 +16.4

+0.3 +0.3 +1.0

11 188.208M 28.2 +0.0 17.0 90.0 -73.0 None -28.9 +16.1

+0.2 +0.3 +1.1

12 199.446M 28.5 +0.0 17.0 90.0 -73.0 None -28.8 +15.8

+0.2 +0.3 +1.0

13 181.151M 27.9 +0.0 16.9 90.0 -73.1 None -28.9 +16.3

+0.3 +0.3 +1.0

14 189.566M 28.1 +0.0 16.9 90.0 -73.1 None -28.9 +16.1

+0.2 +0.3 +1.1

15 189.707M 28.1 +0.0 16.9 90.0 -73.1 None -28.9 +16.1

+0.2 +0.3 +1.1

16 190.096M 28.1 +0.0 16.9 90.0 -73.1 None -28.9 +16.1

+0.2 +0.3 +1.1

17 190.427M 28.1 +0.0 16.9 90.0 -73.1 None -28.9 +16.1

+0.2 +0.3 +1.1

18 199.552M 28.4 +0.0 16.9 90.0 -73.1 None -28.8 +15.8

+0.2 +0.3 +1.0

19 188.210M 27.9 +0.0 16.7 90.0 -73.3 None -28.9 +16.1

+0.2 +0.3 +1.1

20 183.356M 27.6 +0.0 16.6 90.0 -73.4 None -28.9 +16.3

+0.3 +0.3 +1.0

21 191.841M 27.9 +0.0 16.6 90.0 -73.4 None -28.9 +16.0

+0.2 +0.3 +1.1

22 188.207M 27.6 +0.0 16.4 90.0 -73.6 None -28.9 +16.1

+0.2 +0.3 +1.1

23 188.210M 27.6 +0.0 16.4 90.0 -73.6 None -28.9 +16.1

+0.2 +0.3 +1.1

24 189.672M 27.6 +0.0 16.4 90.0 -73.6 None -28.9 +16.1

+0.2 +0.3 +1.1

25 188.207M 27.5 +0.0 16.3 90.0 -73.7 None -28.9 +16.1

+0.2 +0.3 +1.1

26 193.834M 27.6 +0.0 16.3 90.0 -73.7 None -28.9 +16.0

+0.2 +0.3 +1.1

27 190.745M 27.5 +0.0 16.2 90.0 -73.8 None -28.9 +16.0

+0.2 +0.3 +1.1

Page 82: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 82 of 161Report No.: MIL05-043

28 193.268M 27.5 +0.0 16.2 90.0 -73.8 None -28.9 +16.0

+0.2 +0.3 +1.1

29 194.023M 27.5 +0.0 16.2 90.0 -73.8 None -28.9 +16.0

+0.2 +0.3 +1.1

30 198.573M 27.7 +0.0 16.2 90.0 -73.8 None -28.8 +15.8

+0.2 +0.3 +1.0

Page 83: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 83 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 82840 Date: 10/19/2005Test Type: Radiated Scan Time: 1:42:31 PMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 1000.00MHz. 90 (spec limit) - 6dB - 22.7 (Antenna Factor) = 61.3dBuV signal level.

Transducer Legend:T1=8447D OPT 010 AN00686 SN 2944A08591T3=Cable P05309T5=SAS-570 Horn Antenna - 2525

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1

T5T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1000.000M 86.0 +0.0 83.9 90.0 -6.1 None -29.1

+22.8 +0.5 +0.8 +2.9

2 499.900M 54.9 +0.0 44.4 90.0 -45.6 None -29.7 +16.5

+0.4 +0.5 +1.8

3 292.599M 28.3 +0.0 14.6 90.0 -75.4 None -28.4 +12.5

+0.3 +0.4 +1.5

4 286.099M 28.1 +0.0 14.2 90.0 -75.8 None -28.4 +12.4

+0.3 +0.4 +1.4

5 242.900M 28.8 +0.0 13.8 90.0 -76.2 None -28.6 +11.7

+0.3 +0.4 +1.2

6 282.299M 27.6 +0.0 13.4 90.0 -76.6 None -28.5 +12.3

+0.3 +0.4 +1.3

7 283.599M 27.6 +0.0 13.4 90.0 -76.6 None -28.5 +12.3

+0.3 +0.4 +1.3

8 261.099M 28.1 +0.0 13.3 90.0 -76.7 None -28.5 +11.9

+0.3 +0.3 +1.2

9 275.099M 27.6 +0.0 13.2 90.0 -76.8 None -28.5 +12.1

+0.3 +0.4 +1.3

Page 84: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 84 of 161Report No.: MIL05-043

10 282.599M 27.4 +0.0 13.2 90.0 -76.8 None -28.5 +12.3

+0.3 +0.4 +1.3

11 270.299M 27.5 +0.0 13.0 90.0 -77.0 None -28.5 +12.1

+0.3 +0.3 +1.3

12 271.599M 27.5 +0.0 13.0 90.0 -77.0 None -28.5 +12.1

+0.3 +0.3 +1.3

13 279.599M 27.3 +0.0 13.0 90.0 -77.0 None -28.5 +12.2

+0.3 +0.4 +1.3

14 278.399M 27.2 +0.0 12.9 90.0 -77.1 None -28.5 +12.2

+0.3 +0.4 +1.3

15 209.100M 29.3 +0.0 12.8 90.0 -77.2 None -28.8 +10.7

+0.2 +0.3 +1.1

16 264.099M 27.5 +0.0 12.8 90.0 -77.2 None -28.5 +12.0

+0.3 +0.3 +1.2

17 266.099M 27.4 +0.0 12.8 90.0 -77.2 None -28.5 +12.0

+0.3 +0.3 +1.3

18 273.299M 27.3 +0.0 12.8 90.0 -77.2 None -28.5 +12.1

+0.3 +0.3 +1.3

19 273.899M 27.3 +0.0 12.8 90.0 -77.2 None -28.5 +12.1

+0.3 +0.3 +1.3

20 276.899M 27.1 +0.0 12.8 90.0 -77.2 None -28.5 +12.2

+0.3 +0.4 +1.3

21 222.600M 28.2 +0.0 12.4 90.0 -77.6 None -28.7 +11.3

+0.2 +0.3 +1.1

22 225.600M 28.1 +0.0 12.4 90.0 -77.6 None -28.6 +11.3

+0.2 +0.3 +1.1

23 264.699M 27.1 +0.0 12.4 90.0 -77.6 None -28.5 +12.0

+0.3 +0.3 +1.2

24 247.100M 27.3 +0.0 12.3 90.0 -77.7 None -28.6 +11.8

+0.3 +0.3 +1.2

25 220.200M 27.9 +0.0 12.0 90.0 -78.0 None -28.7 +11.2

+0.2 +0.3 +1.1

26 299.999M 25.4 +0.0 12.0 90.0 -78.0 None -28.5 +12.7

+0.3 +0.4 +1.7

27 214.100M 28.2 +0.0 11.9 90.0 -78.1 None -28.8 +10.9

+0.2 +0.3 +1.1

Page 85: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 85 of 161Report No.: MIL05-043

28 219.600M 27.7 +0.0 11.8 90.0 -78.2 None -28.7 +11.2

+0.2 +0.3 +1.1

29 215.500M 27.9 +0.0 11.8 90.0 -78.2 None -28.7 +11.0

+0.2 +0.3 +1.1

30 214.900M 27.9 +0.0 11.7 90.0 -78.3 None -28.8 +11.0

+0.2 +0.3 +1.1

Page 86: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 86 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/19/2005Test Type: Radiated Scan Time: 2:57:09 PMEquipment: Stanford Linear Accelerator Center Sequence#: 5Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=8447D OPT 010 AN00686 SN 2944A08591T3=Cable P05309T5=SAS-570 Horn Antenna - 2525

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1

T5T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 263.964M 54.2 +0.0 39.5 90.0 -50.5 Horiz -28.5

+12.0 +0.3 +0.3 +1.2

2 240.040M 52.9 +0.0 37.9 90.0 -52.1 Horiz -28.6 +11.7

+0.3 +0.4 +1.2

3 266.667M 50.4 +0.0 35.8 90.0 -54.2 Horiz -28.5 +12.0

+0.3 +0.3 +1.3

4 528.028M 42.8 +0.0 32.8 90.0 -57.2 Horiz -29.8 +16.9

+0.4 +0.6 +1.9

5 200.100M 49.4 +0.0 32.4 90.0 -57.6 Horiz -28.8 +10.3

+0.2 +0.3 +1.0

Page 87: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 87 of 161Report No.: MIL05-043

6 479.980M 41.0 +0.0 31.2 90.0 -58.8 Horiz -29.6 +17.2

+0.3 +0.5 +1.8

7 675.175M 39.1 +0.0 30.7 90.0 -59.3 Horiz -29.8 +17.9

+0.5 +0.7 +2.3

8 600.000M 36.2 +0.0 27.5 90.0 -62.5 Horiz -30.0 +18.1

+0.5 +0.5 +2.2

9 459.960M 38.0 +0.0 27.0 90.0 -63.0 Horiz -29.4 +15.7

+0.3 +0.5 +1.9

10 777.277M 33.5 +0.0 26.9 90.0 -63.1 Horiz -29.2 +19.0

+0.5 +0.6 +2.5

11 551.952M 37.3 +0.0 26.5 90.0 -63.5 Horiz -30.0 +16.2

+0.4 +0.6 +2.0

12 979.743M 29.4 +0.0 26.5 90.0 -63.5 Horiz -29.2 +22.2

+0.6 +0.7 +2.8

13 431.932M 39.1 +0.0 26.4 90.0 -63.6 Horiz -29.2 +14.1

+0.3 +0.4 +1.7

14 603.203M 34.8 +0.0 26.0 90.0 -64.0 Horiz -30.0 +18.0

+0.5 +0.5 +2.2

15 947.868M 29.2 +0.0 26.0 90.0 -64.0 Horiz -29.1 +21.6

+0.6 +0.8 +2.9

16 991.063M 28.1 +0.0 25.7 90.0 -64.3 Horiz -29.1 +22.5

+0.5 +0.8 +2.9

17 983.715M 28.2 +0.0 25.4 90.0 -64.6 Horiz -29.2 +22.3

+0.6 +0.7 +2.8

18 300.000M 38.7 +0.0 25.3 90.0 -64.7 Horiz -28.5 +12.7

+0.3 +0.4 +1.7

19 975.870M 28.3 +0.0 25.3 90.0 -64.7 Horiz -29.2 +22.1

+0.6 +0.7 +2.8

20 983.516M 28.1 +0.0 25.3 90.0 -64.7 Horiz -29.2 +22.3

+0.6 +0.7 +2.8

21 312.012M 38.4 +0.0 25.2 90.0 -64.8 Horiz -28.4 +13.1

+0.3 +0.4 +1.4

22 767.967M 31.9 +0.0 25.2 90.0 -64.8 Horiz -29.3 +18.9

+0.5 +0.7 +2.5

23 957.698M 28.4 +0.0 25.2 90.0 -64.8 Horiz -29.2 +21.8

+0.6 +0.7 +2.9

24 967.231M 28.4 +0.0 25.2 90.0 -64.8 Horiz -29.2 +21.9

+0.6 +0.7 +2.8

25 969.018M 28.3 +0.0 25.2 90.0 -64.8 Horiz -29.2 +22.0

+0.6 +0.7 +2.8

26 976.962M 28.2 +0.0 25.2 90.0 -64.8 Horiz -29.2 +22.1

+0.6 +0.7 +2.8

Page 88: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 88 of 161Report No.: MIL05-043

27 996.326M 27.4 +0.0 25.2 90.0 -64.8 Horiz -29.1 +22.7

+0.5 +0.8 +2.9

28 452.853M 36.5 +0.0 25.1 90.0 -64.9 Horiz -29.3 +15.3

+0.3 +0.5 +1.8

29 580.080M 34.4 +0.0 25.1 90.0 -64.9 Horiz -30.0 +17.7

+0.4 +0.6 +2.0

30 971.600M 28.0 +0.0 24.9 90.0 -65.1 Horiz -29.2 +22.0

+0.6 +0.7 +2.8

Page 89: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 89 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/19/2005Test Type: Radiated Scan Time: 2:52:46 PMEquipment: Stanford Linear Accelerator Center Sequence#: 4Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=8447D OPT 010 AN00686 SN 2944A08591T3=Cable P05309T5=SAS-570 Horn Antenna - 2525

T2=3.5' Cable AN 01189T4=Cable 2410

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1

T5T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 240.040M 56.8 +0.0 41.8 90.0 -48.2 Vert -28.6

+11.7 +0.3 +0.4 +1.2

2 600.000M 44.1 +0.0 35.4 90.0 -54.6 Vert -30.0 +18.1

+0.5 +0.5 +2.2

3 603.203M 42.9 +0.0 34.1 90.0 -55.9 Vert -30.0 +18.0

+0.5 +0.5 +2.2

4 479.980M 41.7 +0.0 31.9 90.0 -58.1 Vert -29.6 +17.2

+0.3 +0.5 +1.8

5 336.036M 44.6 +0.0 31.6 90.0 -58.4 Vert -28.5 +13.2

+0.4 +0.4 +1.5

Page 90: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 90 of 161Report No.: MIL05-043

6 559.960M 40.1 +0.0 29.2 90.0 -60.8 Vert -30.0 +16.1

+0.4 +0.6 +2.0

7 312.012M 41.9 +0.0 28.7 90.0 -61.3 Vert -28.4 +13.1

+0.3 +0.4 +1.4

8 200.100M 45.2 +0.0 28.2 90.0 -61.8 Vert -28.8 +10.3

+0.2 +0.3 +1.0

9 600.400M 36.9 +0.0 28.2 90.0 -61.8 Vert -30.0 +18.1

+0.5 +0.5 +2.2

10 959.982M 31.0 +0.0 27.8 90.0 -62.2 Vert -29.2 +21.8

+0.6 +0.7 +2.9

11 432.032M 40.3 +0.0 27.6 90.0 -62.4 Vert -29.2 +14.1

+0.3 +0.4 +1.7

12 551.952M 38.4 +0.0 27.6 90.0 -62.4 Vert -30.0 +16.2

+0.4 +0.6 +2.0

13 767.967M 33.6 +0.0 26.9 90.0 -63.1 Vert -29.3 +18.9

+0.5 +0.7 +2.5

14 528.028M 36.8 +0.0 26.8 90.0 -63.2 Vert -29.8 +16.9

+0.4 +0.6 +1.9

15 620.220M 36.1 +0.0 26.7 90.0 -63.3 Vert -30.0 +17.5

+0.4 +0.5 +2.2

16 989.971M 28.6 +0.0 26.2 90.0 -63.8 Vert -29.1 +22.5

+0.5 +0.8 +2.9

17 863.963M 31.4 +0.0 26.0 90.0 -64.0 Vert -29.1 +19.7

+0.6 +0.7 +2.7

18 825.024M 31.9 +0.0 25.9 90.0 -64.1 Vert -29.2 +19.4

+0.5 +0.6 +2.7

19 979.743M 28.8 +0.0 25.9 90.0 -64.1 Vert -29.2 +22.2

+0.6 +0.7 +2.8

20 992.950M 28.0 +0.0 25.7 90.0 -64.3 Vert -29.1 +22.6

+0.5 +0.8 +2.9

21 955.216M 28.8 +0.0 25.5 90.0 -64.5 Vert -29.2 +21.7

+0.6 +0.7 +2.9

22 973.487M 28.5 +0.0 25.5 90.0 -64.5 Vert -29.2 +22.1

+0.6 +0.7 +2.8

23 980.140M 28.3 +0.0 25.4 90.0 -64.6 Vert -29.2 +22.2

+0.6 +0.7 +2.8

24 890.990M 30.2 +0.0 25.3 90.0 -64.7 Vert -29.1 +20.3

+0.5 +0.7 +2.7

25 945.584M 28.5 +0.0 25.2 90.0 -64.8 Vert -29.1 +21.5

+0.6 +0.8 +2.9

26 994.042M 27.5 +0.0 25.2 90.0 -64.8 Vert -29.1 +22.6

+0.5 +0.8 +2.9

27 953.230M 28.4 +0.0 25.1 90.0 -64.9 Vert -29.2 +21.7

+0.6 +0.7 +2.9

Page 91: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 91 of 161Report No.: MIL05-043

28 957.798M 28.3 +0.0 25.1 90.0 -64.9 Vert -29.2 +21.8

+0.6 +0.7 +2.9

29 972.593M 28.1 +0.0 25.1 90.0 -64.9 Vert -29.2 +22.1

+0.6 +0.7 +2.8

30 931.483M 28.7 +0.0 25.0 90.0 -65.0 Vert -29.1 +21.2

+0.6 +0.8 +2.8

Page 92: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 92 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 10:52:06 AMEquipment: Stanford Linear Accelerator Center Sequence#: 11Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Test Equipment:

Function S/N Calibration Date Cal Due Date Asset #SA - E4446A US44300408 01/13/2005 01/13/2007 02668

Equipment Under Test (* = EUT):Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1195.340M 55.9 +0.0 43.6 90.0 -46.4 Horiz +24.5 -39.7 +1.5 +1.4

2 1199.709M 53.4 +0.0 41.1 90.0 -48.9 Horiz +24.5 -39.7 +1.5 +1.4

3 1022.336M 54.1 +0.0 40.3 90.0 -49.7 Horiz +24.0 -40.5 +1.4 +1.3

4 1061.345M 53.8 +0.0 40.3 90.0 -49.7 Horiz +24.1 -40.3 +1.4 +1.3

Page 93: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 93 of 161Report No.: MIL05-043

5 1191.335M 52.0 +0.0 39.7 90.0 -50.3 Horiz +24.5 -39.7 +1.5 +1.4

6 1051.593M 53.2 +0.0 39.6 90.0 -50.4 Horiz +24.1 -40.4 +1.4 +1.3

7 1482.164M 49.6 +0.0 39.5 90.0 -50.5 Horiz +25.3 -38.7 +1.7 +1.6

8 1328.044M 50.6 +0.0 39.4 90.0 -50.6 Horiz +24.9 -39.2 +1.6 +1.5

9 1162.027M 51.9 +0.0 39.3 90.0 -50.7 Horiz +24.4 -39.9 +1.5 +1.4

10 1326.588M 50.5 +0.0 39.3 90.0 -50.7 Horiz +24.9 -39.2 +1.6 +1.5

11 1475.844M 49.4 +0.0 39.2 90.0 -50.8 Horiz +25.2 -38.7 +1.7 +1.6

12 1376.830M 50.0 +0.0 39.1 90.0 -50.9 Horiz +25.0 -39.0 +1.6 +1.5

13 1536.096M 48.7 +0.0 39.0 90.0 -51.0 Horiz +25.5 -38.6 +1.7 +1.7

14 1099.096M 51.8 +0.0 38.8 90.0 -51.2 Horiz +24.2 -40.1 +1.5 +1.4

15 1358.712M 49.8 +0.0 38.8 90.0 -51.2 Horiz +25.0 -39.1 +1.6 +1.5

16 1501.546M 48.8 +0.0 38.8 90.0 -51.2 Horiz +25.3 -38.6 +1.7 +1.6

17 1546.208M 48.3 +0.0 38.8 90.0 -51.2 Horiz +25.6 -38.5 +1.7 +1.7

18 1145.183M 51.3 +0.0 38.7 90.0 -51.3 Horiz +24.4 -39.9 +1.5 +1.4

19 1189.151M 51.0 +0.0 38.7 90.0 -51.3 Horiz +24.5 -39.7 +1.5 +1.4

20 1358.080M 49.6 +0.0 38.6 90.0 -51.4 Horiz +25.0 -39.1 +1.6 +1.5

21 1483.850M 48.7 +0.0 38.6 90.0 -51.4 Horiz +25.3 -38.7 +1.7 +1.6

22 1519.242M 48.5 +0.0 38.6 90.0 -51.4 Horiz +25.4 -38.6 +1.7 +1.6

23 1166.396M 51.0 +0.0 38.5 90.0 -51.5 Horiz +24.4 -39.8 +1.5 +1.4

24 1250.315M 50.3 +0.0 38.5 90.0 -51.5 Horiz +24.7 -39.5 +1.5 +1.5

25 1442.348M 48.9 +0.0 38.5 90.0 -51.5 Horiz +25.2 -38.8 +1.6 +1.6

26 1519.664M 48.4 +0.0 38.5 90.0 -51.5 Horiz +25.4 -38.6 +1.7 +1.6

Page 94: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 94 of 161Report No.: MIL05-043

27 1153.519M 51.0 +0.0 38.4 90.0 -51.6 Horiz +24.4 -39.9 +1.5 +1.4

28 1168.945M 50.9 +0.0 38.4 90.0 -51.6 Horiz +24.4 -39.8 +1.5 +1.4

29 1505.759M 48.3 +0.0 38.3 90.0 -51.7 Horiz +25.3 -38.6 +1.7 +1.6

30 1513.976M 48.2 +0.0 38.3 90.0 -51.7 Horiz +25.4 -38.6 +1.7 +1.6

Page 95: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 95 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 8:57:42 AMEquipment: Stanford Linear Accelerator Center Sequence#: 6Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1084.782M 56.5 +0.0 43.4 90.0 -46.6 Vert +24.2 -40.2 +1.5 +1.4

2 1133.071M 53.6 +0.0 40.8 90.0 -49.2 Vert +24.3 -40.0 +1.5 +1.4

3 1161.845M 53.1 +0.0 40.5 90.0 -49.5 Vert +24.4 -39.9 +1.5 +1.4

4 1327.680M 51.0 +0.0 39.8 90.0 -50.2 Vert +24.9 -39.2 +1.6 +1.5

5 1333.688M 50.9 +0.0 39.7 90.0 -50.3 Vert +24.9 -39.2 +1.6 +1.5

6 1377.462M 50.4 +0.0 39.5 90.0 -50.5 Vert +25.0 -39.0 +1.6 +1.5

Page 96: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 96 of 161Report No.: MIL05-043

7 1359.976M 50.4 +0.0 39.4 90.0 -50.6 Vert +25.0 -39.1 +1.6 +1.5

8 1194.612M 51.6 +0.0 39.3 90.0 -50.7 Vert +24.5 -39.7 +1.5 +1.4

9 1364.611M 50.1 +0.0 39.1 90.0 -50.9 Vert +25.0 -39.1 +1.6 +1.5

10 1500.703M 49.1 +0.0 39.1 90.0 -50.9 Vert +25.3 -38.6 +1.7 +1.6

11 1536.096M 48.8 +0.0 39.1 90.0 -50.9 Vert +25.5 -38.6 +1.7 +1.7

12 1000.157M 53.0 +0.0 39.0 90.0 -51.0 Vert +23.9 -40.6 +1.4 +1.3

13 1361.240M 50.0 +0.0 39.0 90.0 -51.0 Vert +25.0 -39.1 +1.6 +1.5

14 1433.710M 49.5 +0.0 39.0 90.0 -51.0 Vert +25.1 -38.8 +1.6 +1.6

15 1539.888M 48.7 +0.0 39.0 90.0 -51.0 Vert +25.5 -38.6 +1.7 +1.7

16 1114.196M 51.8 +0.0 38.9 90.0 -51.1 Vert +24.3 -40.1 +1.5 +1.4

17 1518.610M 48.8 +0.0 38.9 90.0 -51.1 Vert +25.4 -38.6 +1.7 +1.6

18 1352.392M 49.9 +0.0 38.8 90.0 -51.2 Vert +24.9 -39.1 +1.6 +1.5

19 1408.219M 49.5 +0.0 38.8 90.0 -51.2 Vert +25.1 -38.9 +1.6 +1.5

20 1539.045M 48.5 +0.0 38.8 90.0 -51.2 Vert +25.5 -38.6 +1.7 +1.7

21 1330.411M 49.9 +0.0 38.7 90.0 -51.3 Vert +24.9 -39.2 +1.6 +1.5

22 1398.318M 49.4 +0.0 38.7 90.0 -51.3 Vert +25.1 -38.9 +1.6 +1.5

23 1523.456M 48.6 +0.0 38.7 90.0 -51.3 Vert +25.4 -38.6 +1.7 +1.6

24 1527.248M 48.4 +0.0 38.7 90.0 -51.3 Vert +25.5 -38.6 +1.7 +1.7

25 1530.829M 48.4 +0.0 38.7 90.0 -51.3 Vert +25.5 -38.6 +1.7 +1.7

26 1045.615M 52.2 +0.0 38.6 90.0 -51.4 Vert +24.1 -40.4 +1.4 +1.3

27 1210.267M 50.8 +0.0 38.6 90.0 -51.4 Vert +24.6 -39.7 +1.5 +1.4

Page 97: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 97 of 161Report No.: MIL05-043

28 1369.035M 49.6 +0.0 38.6 90.0 -51.4 Vert +25.0 -39.1 +1.6 +1.5

29 1316.394M 49.8 +0.0 38.5 90.0 -51.5 Vert +24.8 -39.2 +1.6 +1.5

30 1510.394M 48.4 +0.0 38.5 90.0 -51.5 Vert +25.4 -38.6 +1.7 +1.6

Page 98: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 98 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 11:45:23 AMEquipment: Stanford Linear Accelerator Center Sequence#: 15Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1597.441M 22.5 +0.0 13.2 14.0 -0.8 Horiz +25.8 -38.5 +1.7 +1.7

2 1587.883M 22.2 +0.0 12.9 14.0 -1.1 Horiz +25.8 -38.5 +1.7 +1.7

3 1598.179M 22.0 +0.0 12.7 14.0 -1.3 Horiz +25.8 -38.5 +1.7 +1.7

4 1553.051M 22.1 +0.0 12.6 14.0 -1.4 Horiz +25.6 -38.5 +1.7 +1.7

5 1595.423M 21.8 +0.0 12.5 14.0 -1.5 Horiz +25.8 -38.5 +1.7 +1.7

6 1586.342M 21.7 +0.0 12.4 14.0 -1.6 Horiz +25.8 -38.5 +1.7 +1.7

Page 99: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 99 of 161Report No.: MIL05-043

7 1597.883M 21.7 +0.0 12.4 14.0 -1.6 Horiz +25.8 -38.5 +1.7 +1.7

8 1576.886M 21.7 +0.0 12.3 14.0 -1.7 Horiz +25.7 -38.5 +1.7 +1.7

9 1579.021M 21.7 +0.0 12.3 14.0 -1.7 Horiz +25.7 -38.5 +1.7 +1.7

10 1596.856M 21.6 +0.0 12.3 14.0 -1.7 Horiz +25.8 -38.5 +1.7 +1.7

11 1594.183M 21.5 +0.0 12.2 14.0 -1.8 Horiz +25.8 -38.5 +1.7 +1.7

12 1599.190M 21.5 +0.0 12.2 14.0 -1.8 Horiz +25.8 -38.5 +1.7 +1.7

13 1555.102M 21.6 +0.0 12.1 14.0 -1.9 Horiz +25.6 -38.5 +1.7 +1.7

14 1574.766M 21.5 +0.0 12.1 14.0 -1.9 Horiz +25.7 -38.5 +1.7 +1.7

15 1582.060M 21.5 +0.0 12.1 14.0 -1.9 Horiz +25.7 -38.5 +1.7 +1.7

16 1589.820M 21.4 +0.0 12.1 14.0 -1.9 Horiz +25.8 -38.5 +1.7 +1.7

17 1596.387M 21.4 +0.0 12.1 14.0 -1.9 Horiz +25.8 -38.5 +1.7 +1.7

18 1598.304M 21.4 +0.0 12.1 14.0 -1.9 Horiz +25.8 -38.5 +1.7 +1.7

19 1572.219M 21.4 +0.0 12.0 14.0 -2.0 Horiz +25.7 -38.5 +1.7 +1.7

20 1574.775M 21.4 +0.0 12.0 14.0 -2.0 Horiz +25.7 -38.5 +1.7 +1.7

21 1579.868M 21.4 +0.0 12.0 14.0 -2.0 Horiz +25.7 -38.5 +1.7 +1.7

22 1588.297M 21.3 +0.0 12.0 14.0 -2.0 Horiz +25.8 -38.5 +1.7 +1.7

23 1558.054M 21.4 +0.0 11.9 14.0 -2.1 Horiz +25.6 -38.5 +1.7 +1.7

24 1559.970M 21.4 +0.0 11.9 14.0 -2.1 Horiz +25.6 -38.5 +1.7 +1.7

25 1573.246M 21.3 +0.0 11.9 14.0 -2.1 Horiz +25.7 -38.5 +1.7 +1.7

26 1590.919M 21.2 +0.0 11.9 14.0 -2.1 Horiz +25.8 -38.5 +1.7 +1.7

27 1597.324M 21.2 +0.0 11.9 14.0 -2.1 Horiz +25.8 -38.5 +1.7 +1.7

Page 100: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 100 of 161Report No.: MIL05-043

28 1570.799M 21.2 +0.0 11.8 14.0 -2.2 Horiz +25.7 -38.5 +1.7 +1.7

29 1579.925M 21.2 +0.0 11.8 14.0 -2.2 Horiz +25.7 -38.5 +1.7 +1.7

30 1591.552M 21.1 +0.0 11.8 14.0 -2.2 Horiz +25.8 -38.5 +1.7 +1.7

Page 101: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 101 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHz 1KHz RBWWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 1:29:39 PMEquipment: Stanford Linear Accelerator Center Sequence#: 19Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber. Foil wrapped around J7. Foil fromtop of the unit to the copper table.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1552.897M 22.9 +0.0 13.4 14.0 -0.6 Vert +25.6 -38.5 +1.7 +1.7

2 1584.213M 20.4 +0.0 11.1 14.0 -2.9 Vert +25.8 -38.5 +1.7 +1.7

3 1597.442M 20.3 +0.0 11.0 14.0 -3.0 Vert +25.8 -38.5 +1.7 +1.7

4 1582.952M 19.8 +0.0 10.4 14.0 -3.6 Vert +25.7 -38.5 +1.7 +1.7

5 1562.915M 18.7 +0.0 9.2 14.0 -4.8 Vert +25.6 -38.5 +1.7 +1.7

Page 102: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 102 of 161Report No.: MIL05-043

6 1595.277M 18.5 +0.0 9.2 14.0 -4.8 Vert +25.8 -38.5 +1.7 +1.7

7 1592.687M 18.3 +0.0 9.0 14.0 -5.0 Vert +25.8 -38.5 +1.7 +1.7

8 1597.490M 18.2 +0.0 8.9 14.0 -5.1 Vert +25.8 -38.5 +1.7 +1.7

9 1572.398M 17.9 +0.0 8.5 14.0 -5.5 Vert +25.7 -38.5 +1.7 +1.7

10 1582.655M 17.9 +0.0 8.5 14.0 -5.5 Vert +25.7 -38.5 +1.7 +1.7

11 1592.479M 17.8 +0.0 8.5 14.0 -5.5 Vert +25.8 -38.5 +1.7 +1.7

12 1592.503M 17.7 +0.0 8.4 14.0 -5.6 Vert +25.8 -38.5 +1.7 +1.7

13 1559.988M 17.8 +0.0 8.3 14.0 -5.7 Vert +25.6 -38.5 +1.7 +1.7

14 1592.148M 17.6 +0.0 8.3 14.0 -5.7 Vert +25.8 -38.5 +1.7 +1.7

15 1550.077M 17.7 +0.0 8.2 14.0 -5.8 Vert +25.6 -38.5 +1.7 +1.7

16 1575.157M 17.5 +0.0 8.1 14.0 -5.9 Vert +25.7 -38.5 +1.7 +1.7

17 1588.289M 17.4 +0.0 8.1 14.0 -5.9 Vert +25.8 -38.5 +1.7 +1.7

18 1577.941M 17.4 +0.0 8.0 14.0 -6.0 Vert +25.7 -38.5 +1.7 +1.7

19 1592.238M 17.3 +0.0 8.0 14.0 -6.0 Vert +25.8 -38.5 +1.7 +1.7

20 1550.598M 17.4 +0.0 7.9 14.0 -6.1 Vert +25.6 -38.5 +1.7 +1.7

21 1592.823M 17.2 +0.0 7.9 14.0 -6.1 Vert +25.8 -38.5 +1.7 +1.7

22 1553.176M 17.3 +0.0 7.8 14.0 -6.2 Vert +25.6 -38.5 +1.7 +1.7

23 1575.426M 17.2 +0.0 7.8 14.0 -6.2 Vert +25.7 -38.5 +1.7 +1.7

24 1591.227M 17.1 +0.0 7.8 14.0 -6.2 Vert +25.8 -38.5 +1.7 +1.7

25 1591.531M 17.1 +0.0 7.8 14.0 -6.2 Vert +25.8 -38.5 +1.7 +1.7

26 1596.227M 17.1 +0.0 7.8 14.0 -6.2 Vert +25.8 -38.5 +1.7 +1.7

Page 103: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 103 of 161Report No.: MIL05-043

27 1583.030M 17.1 +0.0 7.7 14.0 -6.3 Vert +25.7 -38.5 +1.7 +1.7

28 1591.284M 17.0 +0.0 7.7 14.0 -6.3 Vert +25.8 -38.5 +1.7 +1.7

29 1594.497M 17.0 +0.0 7.7 14.0 -6.3 Vert +25.8 -38.5 +1.7 +1.7

30 1575.048M 17.0 +0.0 7.6 14.0 -6.4 Vert +25.7 -38.5 +1.7 +1.7

Page 104: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 104 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 10:53:46 AMEquipment: Stanford Linear Accelerator Center Sequence#: 12Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1728.640M 49.8 +0.0 41.5 90.0 -48.5 Horiz +26.5 -38.4 +1.8 +1.8

2 1767.129M 49.4 +0.0 41.4 90.0 -48.6 Horiz +26.7 -38.3 +1.8 +1.8

3 1730.807M 49.6 +0.0 41.3 90.0 -48.7 Horiz +26.5 -38.4 +1.8 +1.8

4 1681.507M 49.5 +0.0 41.0 90.0 -49.0 Horiz +26.3 -38.4 +1.8 +1.8

5 1635.272M 49.8 +0.0 40.9 90.0 -49.1 Horiz +26.0 -38.4 +1.8 +1.7

6 1749.613M 49.0 +0.0 40.9 90.0 -49.1 Horiz +26.6 -38.3 +1.8 +1.8

Page 105: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 105 of 161Report No.: MIL05-043

7 1611.830M 50.0 +0.0 40.8 90.0 -49.2 Horiz +25.9 -38.5 +1.7 +1.7

8 1719.266M 49.2 +0.0 40.8 90.0 -49.2 Horiz +26.4 -38.4 +1.8 +1.8

9 1727.292M 49.1 +0.0 40.8 90.0 -49.2 Horiz +26.5 -38.4 +1.8 +1.8

10 1760.216M 48.9 +0.0 40.8 90.0 -49.2 Horiz +26.6 -38.3 +1.8 +1.8

11 1762.677M 48.9 +0.0 40.8 90.0 -49.2 Horiz +26.6 -38.3 +1.8 +1.8

12 1650.498M 49.5 +0.0 40.7 90.0 -49.3 Horiz +26.1 -38.4 +1.8 +1.7

13 1682.753M 49.2 +0.0 40.7 90.0 -49.3 Horiz +26.3 -38.4 +1.8 +1.8

14 1742.758M 48.8 +0.0 40.7 90.0 -49.3 Horiz +26.6 -38.3 +1.8 +1.8

15 1761.095M 48.8 +0.0 40.7 90.0 -49.3 Horiz +26.6 -38.3 +1.8 +1.8

16 1600.274M 49.9 +0.0 40.6 90.0 -49.4 Horiz +25.8 -38.5 +1.7 +1.7

17 1627.659M 49.6 +0.0 40.6 90.0 -49.4 Horiz +26.0 -38.5 +1.8 +1.7

18 1714.286M 49.0 +0.0 40.6 90.0 -49.4 Horiz +26.4 -38.4 +1.8 +1.8

19 1760.685M 48.7 +0.0 40.6 90.0 -49.4 Horiz +26.6 -38.3 +1.8 +1.8

20 1702.013M 48.9 +0.0 40.5 90.0 -49.5 Horiz +26.4 -38.4 +1.8 +1.8

21 1672.500M 49.1 +0.0 40.4 90.0 -49.6 Horiz +26.2 -38.4 +1.8 +1.7

22 1674.653M 49.1 +0.0 40.4 90.0 -49.6 Horiz +26.2 -38.4 +1.8 +1.7

23 1685.359M 48.9 +0.0 40.4 90.0 -49.6 Horiz +26.3 -38.4 +1.8 +1.8

24 1699.577M 48.9 +0.0 40.4 90.0 -49.6 Horiz +26.3 -38.4 +1.8 +1.8

25 1659.189M 49.1 +0.0 40.3 90.0 -49.7 Horiz +26.1 -38.4 +1.8 +1.7

26 1666.326M 49.0 +0.0 40.3 90.0 -49.7 Horiz +26.2 -38.4 +1.8 +1.7

Page 106: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 106 of 161Report No.: MIL05-043

27 1712.470M 48.7 +0.0 40.3 90.0 -49.7 Horiz +26.4 -38.4 +1.8 +1.8

28 1724.597M 48.6 +0.0 40.3 90.0 -49.7 Horiz +26.5 -38.4 +1.8 +1.8

29 1734.615M 48.5 +0.0 40.3 90.0 -49.7 Horiz +26.5 -38.3 +1.8 +1.8

30 1739.595M 48.5 +0.0 40.3 90.0 -49.7 Horiz +26.5 -38.3 +1.8 +1.8

Page 107: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 107 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 9:00:09 AMEquipment: Stanford Linear Accelerator Center Sequence#: 7Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 1763.790M 49.4 +0.0 41.4 90.0 -48.6 Vert +26.7 -38.3 +1.8 +1.8

2 1767.481M 49.3 +0.0 41.3 90.0 -48.7 Vert +26.7 -38.3 +1.8 +1.8

3 1768.008M 49.0 +0.0 41.0 90.0 -49.0 Vert +26.7 -38.3 +1.8 +1.8

4 1762.091M 49.0 +0.0 40.9 90.0 -49.1 Vert +26.6 -38.3 +1.8 +1.8

5 1762.384M 49.0 +0.0 40.9 90.0 -49.1 Vert +26.6 -38.3 +1.8 +1.8

6 1763.497M 48.8 +0.0 40.8 90.0 -49.2 Vert +26.7 -38.3 +1.8 +1.8

Page 108: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 108 of 161Report No.: MIL05-043

7 1710.113M 49.1 +0.0 40.7 90.0 -49.3 Vert +26.4 -38.4 +1.8 +1.8

8 1755.940M 48.8 +0.0 40.7 90.0 -49.3 Vert +26.6 -38.3 +1.8 +1.8

9 1675.786M 49.2 +0.0 40.6 90.0 -49.4 Vert +26.2 -38.4 +1.8 +1.8

10 1754.651M 48.7 +0.0 40.6 90.0 -49.4 Vert +26.6 -38.3 +1.8 +1.8

11 1679.411M 49.1 +0.0 40.5 90.0 -49.5 Vert +26.2 -38.4 +1.8 +1.8

12 1700.710M 49.0 +0.0 40.5 90.0 -49.5 Vert +26.3 -38.4 +1.8 +1.8

13 1711.359M 48.9 +0.0 40.5 90.0 -49.5 Vert +26.4 -38.4 +1.8 +1.8

14 1713.642M 48.9 +0.0 40.5 90.0 -49.5 Vert +26.4 -38.4 +1.8 +1.8

15 1727.409M 48.8 +0.0 40.5 90.0 -49.5 Vert +26.5 -38.4 +1.8 +1.8

16 1731.452M 48.8 +0.0 40.5 90.0 -49.5 Vert +26.5 -38.4 +1.8 +1.8

17 1618.074M 49.6 +0.0 40.4 90.0 -49.6 Vert +25.9 -38.5 +1.7 +1.7

18 1733.209M 48.6 +0.0 40.4 90.0 -49.6 Vert +26.5 -38.3 +1.8 +1.8

19 1754.768M 48.5 +0.0 40.4 90.0 -49.6 Vert +26.6 -38.3 +1.8 +1.8

20 1628.974M 49.2 +0.0 40.2 90.0 -49.8 Vert +26.0 -38.5 +1.8 +1.7

21 1707.904M 48.6 +0.0 40.2 90.0 -49.8 Vert +26.4 -38.4 +1.8 +1.8

22 1634.012M 49.0 +0.0 40.0 90.0 -50.0 Vert +26.0 -38.5 +1.8 +1.7

23 1650.882M 48.8 +0.0 40.0 90.0 -50.0 Vert +26.1 -38.4 +1.8 +1.7

24 1701.446M 48.4 +0.0 40.0 90.0 -50.0 Vert +26.4 -38.4 +1.8 +1.8

25 1702.409M 48.4 +0.0 40.0 90.0 -50.0 Vert +26.4 -38.4 +1.8 +1.8

26 1640.201M 48.8 +0.0 39.9 90.0 -50.1 Vert +26.0 -38.4 +1.8 +1.7

27 1645.624M 48.7 +0.0 39.9 90.0 -50.1 Vert +26.1 -38.4 +1.8 +1.7

Page 109: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 109 of 161Report No.: MIL05-043

28 1705.185M 48.3 +0.0 39.9 90.0 -50.1 Vert +26.4 -38.4 +1.8 +1.8

29 1633.410M 48.8 +0.0 39.8 90.0 -50.2 Vert +26.0 -38.5 +1.8 +1.7

30 1648.034M 48.6 +0.0 39.8 90.0 -50.2 Vert +26.1 -38.4 +1.8 +1.7

Page 110: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 110 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 11:39:34 AMEquipment: Stanford Linear Accelerator Center Sequence#: 14Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 2196.486M 29.8 +0.0 23.7 25.0 -1.3 Horiz +27.9 -38.0 +2.0 +2.0

2 2100.000M 28.0 +0.0 21.7 25.0 -3.3 Horiz +27.8 -38.0 +2.0 +1.9

3 1803.503M 29.1 +0.0 21.2 25.0 -3.8 Horiz +26.8 -38.3 +1.8 +1.8

4 2259.329M 26.8 +0.0 20.9 25.0 -4.1 Horiz +27.9 -37.9 +2.1 +2.0

5 2077.107M 27.1 +0.0 20.8 25.0 -4.2 Horiz +27.8 -38.0 +2.0 +1.9

6 2103.934M 27.0 +0.0 20.7 25.0 -4.3 Horiz +27.8 -38.0 +2.0 +1.9

Page 111: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 111 of 161Report No.: MIL05-043

7 1929.469M 27.6 +0.0 20.6 25.0 -4.4 Horiz +27.4 -38.2 +1.9 +1.9

8 2118.478M 26.9 +0.0 20.6 25.0 -4.4 Horiz +27.8 -38.0 +2.0 +1.9

9 1974.144M 27.2 +0.0 20.5 25.0 -4.5 Horiz +27.6 -38.1 +1.9 +1.9

10 2237.487M 26.5 +0.0 20.5 25.0 -4.5 Horiz +27.9 -37.9 +2.0 +2.0

11 2291.705M 26.4 +0.0 20.5 25.0 -4.5 Horiz +27.9 -37.9 +2.1 +2.0

12 2037.487M 27.0 +0.0 20.4 25.0 -4.6 Horiz +27.7 -38.1 +1.9 +1.9

13 2038.749M 27.0 +0.0 20.4 25.0 -4.6 Horiz +27.7 -38.1 +1.9 +1.9

14 2078.909M 26.7 +0.0 20.4 25.0 -4.6 Horiz +27.8 -38.0 +2.0 +1.9

15 2219.939M 26.5 +0.0 20.4 25.0 -4.6 Horiz +27.9 -38.0 +2.0 +2.0

16 1925.355M 27.3 +0.0 20.3 25.0 -4.7 Horiz +27.4 -38.2 +1.9 +1.9

17 2085.305M 26.6 +0.0 20.3 25.0 -4.7 Horiz +27.8 -38.0 +2.0 +1.9

18 2118.538M 26.6 +0.0 20.3 25.0 -4.7 Horiz +27.8 -38.0 +2.0 +1.9

19 2127.697M 26.6 +0.0 20.3 25.0 -4.7 Horiz +27.8 -38.0 +2.0 +1.9

20 2181.511M 26.4 +0.0 20.3 25.0 -4.7 Horiz +27.9 -38.0 +2.0 +2.0

21 2230.640M 26.4 +0.0 20.3 25.0 -4.7 Horiz +27.9 -38.0 +2.0 +2.0

22 2256.476M 26.2 +0.0 20.3 25.0 -4.7 Horiz +27.9 -37.9 +2.1 +2.0

23 2292.938M 26.2 +0.0 20.3 25.0 -4.7 Horiz +27.9 -37.9 +2.1 +2.0

24 1873.083M 27.5 +0.0 20.2 25.0 -4.8 Horiz +27.2 -38.2 +1.9 +1.8

25 2033.764M 26.8 +0.0 20.2 25.0 -4.8 Horiz +27.7 -38.1 +1.9 +1.9

26 2091.031M 26.5 +0.0 20.2 25.0 -4.8 Horiz +27.8 -38.0 +2.0 +1.9

27 2152.512M 26.4 +0.0 20.2 25.0 -4.8 Horiz +27.8 -38.0 +2.0 +2.0

Page 112: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 112 of 161Report No.: MIL05-043

28 2224.905M 26.3 +0.0 20.2 25.0 -4.8 Horiz +27.9 -38.0 +2.0 +2.0

29 2258.428M 26.1 +0.0 20.2 25.0 -4.8 Horiz +27.9 -37.9 +2.1 +2.0

30 2266.306M 26.0 +0.0 20.1 25.0 -4.9 Horiz +27.9 -37.9 +2.1 +2.0

Page 113: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 113 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 10:46:34 AMEquipment: Stanford Linear Accelerator Center Sequence#: 10Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 2196.486M 29.4 +0.0 23.3 25.0 -1.7 Vert +27.9 -38.0 +2.0 +2.0

2 2103.833M 29.5 +0.0 23.2 25.0 -1.8 Vert +27.8 -38.0 +2.0 +1.9

3 1803.293M 30.8 +0.0 22.9 25.0 -2.1 Vert +26.8 -38.3 +1.8 +1.8

4 1991.742M 28.9 +0.0 22.3 25.0 -2.7 Vert +27.7 -38.1 +1.9 +1.9

5 1797.117M 29.9 +0.0 22.0 25.0 -3.0 Vert +26.8 -38.3 +1.8 +1.8

6 2026.596M 27.9 +0.0 21.3 25.0 -3.7 Vert +27.7 -38.1 +1.9 +1.9

Page 114: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 114 of 161Report No.: MIL05-043

7 1994.975M 27.8 +0.0 21.2 25.0 -3.8 Vert +27.7 -38.1 +1.9 +1.9

8 2098.328M 27.3 +0.0 21.0 25.0 -4.0 Vert +27.8 -38.0 +2.0 +1.9

9 1979.709M 27.6 +0.0 20.9 25.0 -4.1 Vert +27.6 -38.1 +1.9 +1.9

10 1996.807M 27.5 +0.0 20.9 25.0 -4.1 Vert +27.7 -38.1 +1.9 +1.9

11 2103.653M 27.1 +0.0 20.8 25.0 -4.2 Vert +27.8 -38.0 +2.0 +1.9

12 2193.303M 26.9 +0.0 20.8 25.0 -4.2 Vert +27.9 -38.0 +2.0 +2.0

13 1797.147M 28.6 +0.0 20.7 25.0 -4.3 Vert +26.8 -38.3 +1.8 +1.8

14 1946.416M 27.5 +0.0 20.7 25.0 -4.3 Vert +27.5 -38.1 +1.9 +1.9

15 2029.079M 27.3 +0.0 20.7 25.0 -4.3 Vert +27.7 -38.1 +1.9 +1.9

16 2078.438M 27.0 +0.0 20.7 25.0 -4.3 Vert +27.8 -38.0 +2.0 +1.9

17 2173.163M 26.9 +0.0 20.7 25.0 -4.3 Vert +27.8 -38.0 +2.0 +2.0

18 1822.693M 28.4 +0.0 20.6 25.0 -4.4 Vert +26.9 -38.3 +1.8 +1.8

19 2188.958M 26.7 +0.0 20.6 25.0 -4.4 Vert +27.9 -38.0 +2.0 +2.0

20 2212.642M 26.6 +0.0 20.5 25.0 -4.5 Vert +27.9 -38.0 +2.0 +2.0

21 2037.287M 27.0 +0.0 20.4 25.0 -4.6 Vert +27.7 -38.1 +1.9 +1.9

22 2075.775M 26.8 +0.0 20.4 25.0 -4.6 Vert +27.8 -38.1 +2.0 +1.9

23 2085.035M 26.7 +0.0 20.4 25.0 -4.6 Vert +27.8 -38.0 +2.0 +1.9

24 2088.568M 26.7 +0.0 20.4 25.0 -4.6 Vert +27.8 -38.0 +2.0 +1.9

25 2125.405M 26.7 +0.0 20.4 25.0 -4.6 Vert +27.8 -38.0 +2.0 +1.9

26 2129.850M 26.7 +0.0 20.4 25.0 -4.6 Vert +27.8 -38.0 +2.0 +1.9

Page 115: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 115 of 161Report No.: MIL05-043

27 2095.005M 26.6 +0.0 20.3 25.0 -4.7 Vert +27.8 -38.0 +2.0 +1.9

28 2219.619M 26.4 +0.0 20.3 25.0 -4.7 Vert +27.9 -38.0 +2.0 +2.0

29 2241.661M 26.3 +0.0 20.3 25.0 -4.7 Vert +27.9 -37.9 +2.0 +2.0

30 2260.970M 26.2 +0.0 20.3 25.0 -4.7 Vert +27.9 -37.9 +2.1 +2.0

Page 116: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 116 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 8:28:29 AMEquipment: Sequence#: 0Manufacturer: Tested By: A. BrarModel:S/N:Equipment Under Test (* = EUT):

Function Manufacturer Model # S/N

Support Devices:Function Manufacturer Model # S/N

Test Conditions / Notes:Path Check Sweep. Signal at 1000.00MHz. 90 (spec limit) - 6dB - 45.9 (Antenna Factor) = 38.1dBuV = -68.9dBmsignal level.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: None# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 17995.080M 61.8 +0.0 86.5 90.0 -3.5 Pre-C +45.9 -33.5 +6.4 +5.9

2 17976.380M 42.5 +0.0 67.1 90.0 -22.9 Pre-C +45.8 -33.5 +6.4 +5.9

3 17921.280M 42.5 +0.0 66.7 90.0 -23.3 Pre-C +45.5 -33.6 +6.4 +5.9

4 17970.480M 42.2 +0.0 66.7 90.0 -23.3 Pre-C +45.7 -33.5 +6.4 +5.9

5 17951.780M 42.1 +0.0 66.5 90.0 -23.5 Pre-C +45.7 -33.6 +6.4 +5.9

6 17895.700M 42.3 +0.0 66.4 90.0 -23.6 Pre-C +45.4 -33.6 +6.4 +5.9

7 17885.860M 42.2 +0.0 66.1 90.0 -23.9 Pre-C +45.3 -33.7 +6.4 +5.9

8 17845.510M 42.3 +0.0 66.0 90.0 -24.0 Pre-C +45.1 -33.7 +6.4 +5.9

9 17862.240M 42.2 +0.0 66.0 90.0 -24.0 Pre-C +45.2 -33.7 +6.4 +5.9

10 17570.980M 42.9 +0.0 64.6 90.0 -25.4 Pre-C +43.7 -34.1 +6.3 +5.8

Page 117: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 117 of 161Report No.: MIL05-043

11 17622.140M 42.4 +0.0 64.4 90.0 -25.6 Pre-C +43.9 -34.0 +6.3 +5.8

12 17290.540M 44.4 +0.0 63.8 90.0 -26.2 Pre-C +41.7 -34.3 +6.2 +5.8

13 17452.900M 42.8 +0.0 63.6 90.0 -26.4 Pre-C +42.9 -34.2 +6.3 +5.8

14 17488.320M 42.2 +0.0 63.3 90.0 -26.7 Pre-C +43.2 -34.2 +6.3 +5.8

15 17503.080M 42.1 +0.0 63.3 90.0 -26.7 Pre-C +43.3 -34.2 +6.3 +5.8

16 17389.920M 42.6 +0.0 63.0 90.0 -27.0 Pre-C +42.5 -34.2 +6.3 +5.8

17 17326.940M 43.2 +0.0 62.9 90.0 -27.1 Pre-C +42.0 -34.3 +6.2 +5.8

18 17349.580M 43.0 +0.0 62.9 90.0 -27.1 Pre-C +42.2 -34.3 +6.2 +5.8

19 17356.460M 42.8 +0.0 62.7 90.0 -27.3 Pre-C +42.2 -34.3 +6.2 +5.8

20 16992.980M 43.4 +0.0 60.3 90.0 -29.7 Pre-C +39.5 -34.4 +6.1 +5.7

21 14557.540M 43.0 +0.0 59.1 90.0 -30.9 Pre-C +40.9 -35.8 +5.8 +5.2

22 16863.850M 42.9 +0.0 59.1 90.0 -30.9 Pre-C +38.9 -34.5 +6.1 +5.7

23 13775.760M 44.2 +0.0 59.0 90.0 -31.0 Pre-C +39.8 -35.8 +5.7 +5.1

24 14458.450M 42.8 +0.0 59.0 90.0 -31.0 Pre-C +41.0 -35.8 +5.8 +5.2

25 16890.880M 42.7 +0.0 59.0 90.0 -31.0 Pre-C +39.0 -34.5 +6.1 +5.7

26 14420.410M 42.8 +0.0 58.9 90.0 -31.1 Pre-C +40.9 -35.8 +5.8 +5.2

27 14509.500M 42.5 +0.0 58.8 90.0 -31.2 Pre-C +41.1 -35.8 +5.8 +5.2

Page 118: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 118 of 161Report No.: MIL05-043

28 14526.510M 42.6 +0.0 58.8 90.0 -31.2 Pre-C +41.0 -35.8 +5.8 +5.2

29 14447.430M 42.5 +0.0 58.7 90.0 -31.3 Pre-C +41.0 -35.8 +5.8 +5.2

30 16895.880M 42.3 +0.0 58.7 90.0 -31.3 Pre-C +39.1 -34.5 +6.1 +5.7

Page 119: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 119 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 10:57:03 AMEquipment: Stanford Linear Accelerator Center Sequence#: 13Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 17998.630M 42.4 +0.0 67.1 90.0 -22.9 Horiz +45.9 -33.5 +6.4 +5.9

2 17771.890M 43.1 +0.0 66.3 90.0 -23.7 Horiz +44.7 -33.8 +6.4 +5.9

3 17879.440M 42.2 +0.0 66.1 90.0 -23.9 Horiz +45.3 -33.7 +6.4 +5.9

4 17846.560M 42.2 +0.0 65.9 90.0 -24.1 Horiz +45.1 -33.7 +6.4 +5.9

5 17861.630M 41.9 +0.0 65.7 90.0 -24.3 Horiz +45.2 -33.7 +6.4 +5.9

6 17591.740M 43.1 +0.0 64.9 90.0 -25.1 Horiz +43.8 -34.1 +6.3 +5.8

Page 120: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 120 of 161Report No.: MIL05-043

7 17552.010M 42.8 +0.0 64.4 90.0 -25.6 Horiz +43.6 -34.1 +6.3 +5.8

8 17563.650M 42.5 +0.0 64.1 90.0 -25.9 Horiz +43.6 -34.1 +6.3 +5.8

9 17608.180M 42.1 +0.0 64.1 90.0 -25.9 Horiz +43.9 -34.0 +6.3 +5.8

10 17618.460M 42.1 +0.0 64.1 90.0 -25.9 Horiz +43.9 -34.0 +6.3 +5.8

11 17388.290M 43.6 +0.0 64.0 90.0 -26.0 Horiz +42.5 -34.2 +6.3 +5.8

12 17392.400M 43.0 +0.0 63.4 90.0 -26.6 Horiz +42.5 -34.2 +6.3 +5.8

13 17425.970M 42.7 +0.0 63.3 90.0 -26.7 Horiz +42.7 -34.2 +6.3 +5.8

14 17301.990M 42.9 +0.0 62.4 90.0 -27.6 Horiz +41.8 -34.3 +6.2 +5.8

15 17261.950M 43.0 +0.0 62.2 90.0 -27.8 Horiz +41.5 -34.3 +6.2 +5.8

16 14473.160M 43.4 +0.0 59.6 90.0 -30.4 Horiz +41.0 -35.8 +5.8 +5.2

17 16880.570M 43.0 +0.0 59.3 90.0 -30.7 Horiz +39.0 -34.5 +6.1 +5.7

18 14458.150M 42.9 +0.0 59.1 90.0 -30.9 Horiz +41.0 -35.8 +5.8 +5.2

19 16927.610M 42.4 +0.0 58.9 90.0 -31.1 Horiz +39.2 -34.5 +6.1 +5.7

20 14307.000M 43.0 +0.0 58.8 90.0 -31.2 Horiz +40.7 -35.9 +5.8 +5.2

21 13992.680M 43.9 +0.0 58.7 90.0 -31.3 Horiz +40.1 -36.1 +5.7 +5.1

22 14110.800M 43.5 +0.0 58.6 90.0 -31.4 Horiz +40.3 -36.0 +5.7 +5.1

23 14331.020M 42.7 +0.0 58.6 90.0 -31.4 Horiz +40.8 -35.9 +5.8 +5.2

24 14977.670M 43.6 +0.0 58.6 90.0 -31.4 Horiz +39.1 -35.4 +6.0 +5.3

25 14177.870M 43.2 +0.0 58.5 90.0 -31.5 Horiz +40.5 -36.0 +5.7 +5.1

26 14283.970M 42.6 +0.0 58.4 90.0 -31.6 Horiz +40.7 -35.9 +5.8 +5.2

Page 121: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 121 of 161Report No.: MIL05-043

27 13831.520M 43.5 +0.0 58.3 90.0 -31.7 Horiz +39.9 -35.9 +5.7 +5.1

28 13916.610M 43.4 +0.0 58.2 90.0 -31.8 Horiz +40.0 -36.0 +5.7 +5.1

29 14261.950M 42.5 +0.0 58.2 90.0 -31.8 Horiz +40.6 -35.9 +5.8 +5.2

30 16752.440M 42.5 +0.0 58.2 90.0 -31.8 Horiz +38.5 -34.6 +6.1 +5.7

Page 122: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 122 of 161Report No.: MIL05-043

Test Location: CKC Laboratories, Inc. •1120 Fulton Place • Fremont, CA 94539 • (510) 249 - 1170

Customer: Stanford Linear Accelerator CenterSpecification: RE102 10KHz-18GHzWork Order #: 83492 Date: 10/20/2005Test Type: Radiated Scan Time: 9:02:30 AMEquipment: Stanford Linear Accelerator Center Sequence#: 8Manufacturer: Stanford Linear Tested By: A. BrarModel: SIUS/N: GLAT 2508Equipment Under Test (* = EUT):

Function Manufacturer Model # S/NStanford Linear Accelerator Center* Stanford Linear SIU GLAT 2508

Support Devices:Function Manufacturer Model # S/NPower Supply AEMC Instruments AX502 PC70344VME Crate Dawn 11-1011777-2119 002563Mouse Dell by Microsoft X06-08477 noneKeyboard Dell 04N454 TH-04N454-37171-33F-E488Monitor Dell MX-D9J367-47605-379-AYKJ PC65341PC Dell DHM JLJJ331

Test Conditions / Notes:Unit is running register test and also exercising the cPCI backplane. Setup is per the test plan TP05-83492-0. The10uF capacitors are shielded using a cage. The power cable is grounded to the copper table as it exits the cage.Power cable is grounded to the chamber wall right before it enters the chamber.

Transducer Legend:T1=Horn Antenna AN02113 SN4660 (Fremont)T3=CAB HF 72" ANP05317 Pasternack

T2=HP-83017A, A/N 00785T4=Cable AN2716 40 GHz

Measurement Data: Reading listed by margin. Test Distance: 1 Meter# Freq Rdng T1 T2 T3 T4 Dist Corr Spec Margin Polar

MHz dBµV dB dB dB dB Table dBµV/m dBµV/m dB Ant 1 17981.510M 42.6 +0.0 67.2 90.0 -22.8 Vert +45.8 -33.5 +6.4 +5.9

2 17986.980M 42.2 +0.0 66.8 90.0 -23.2 Vert +45.8 -33.5 +6.4 +5.9

3 17785.600M 42.8 +0.0 66.1 90.0 -23.9 Vert +44.8 -33.8 +6.4 +5.9

4 17753.400M 42.7 +0.0 65.8 90.0 -24.2 Vert +44.6 -33.8 +6.4 +5.9

5 17812.310M 42.4 +0.0 65.8 90.0 -24.2 Vert +44.9 -33.8 +6.4 +5.9

6 17727.370M 43.0 +0.0 65.7 90.0 -24.3 Vert +44.5 -33.9 +6.3 +5.8

Page 123: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 123 of 161Report No.: MIL05-043

7 17679.420M 43.0 +0.0 65.4 90.0 -24.6 Vert +44.2 -33.9 +6.3 +5.8

8 17686.270M 42.7 +0.0 65.2 90.0 -24.8 Vert +44.3 -33.9 +6.3 +5.8

9 17690.380M 42.6 +0.0 65.1 90.0 -24.9 Vert +44.3 -33.9 +6.3 +5.8

10 17458.850M 43.7 +0.0 64.6 90.0 -25.4 Vert +43.0 -34.2 +6.3 +5.8

11 17466.380M 43.4 +0.0 64.3 90.0 -25.7 Vert +43.0 -34.2 +6.3 +5.8

12 17543.110M 42.4 +0.0 63.9 90.0 -26.1 Vert +43.5 -34.1 +6.3 +5.8

13 17421.180M 43.2 +0.0 63.8 90.0 -26.2 Vert +42.7 -34.2 +6.3 +5.8

14 17468.440M 42.8 +0.0 63.8 90.0 -26.2 Vert +43.1 -34.2 +6.3 +5.8

15 17391.720M 43.1 +0.0 63.5 90.0 -26.5 Vert +42.5 -34.2 +6.3 +5.8

16 17384.190M 43.1 +0.0 63.4 90.0 -26.6 Vert +42.4 -34.2 +6.3 +5.8

17 17435.560M 42.6 +0.0 63.3 90.0 -26.7 Vert +42.8 -34.2 +6.3 +5.8

18 17446.520M 42.4 +0.0 63.2 90.0 -26.8 Vert +42.9 -34.2 +6.3 +5.8

19 17311.000M 42.9 +0.0 62.5 90.0 -27.5 Vert +41.9 -34.3 +6.2 +5.8

20 17029.710M 43.6 +0.0 60.7 90.0 -29.3 Vert +39.7 -34.4 +6.1 +5.7

21 17025.710M 43.0 +0.0 60.1 90.0 -29.9 Vert +39.7 -34.4 +6.1 +5.7

22 14425.110M 43.7 +0.0 59.9 90.0 -30.1 Vert +41.0 -35.8 +5.8 +5.2

23 14482.170M 43.5 +0.0 59.8 90.0 -30.2 Vert +41.1 -35.8 +5.8 +5.2

24 14496.180M 43.4 +0.0 59.7 90.0 -30.3 Vert +41.1 -35.8 +5.8 +5.2

25 16938.620M 43.2 +0.0 59.7 90.0 -30.3 Vert +39.2 -34.5 +6.1 +5.7

26 17000.690M 42.8 +0.0 59.7 90.0 -30.3 Vert +39.5 -34.4 +6.1 +5.7

Page 124: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 124 of 161Report No.: MIL05-043

27 16944.630M 43.0 +0.0 59.6 90.0 -30.4 Vert +39.3 -34.5 +6.1 +5.7

28 16959.640M 42.9 +0.0 59.6 90.0 -30.4 Vert +39.3 -34.4 +6.1 +5.7

29 16948.630M 42.9 +0.0 59.5 90.0 -30.5 Vert +39.3 -34.5 +6.1 +5.7

30 16973.660M 42.6 +0.0 59.4 90.0 -30.6 Vert +39.4 -34.4 +6.1 +5.7

Page 125: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 125 of 161Report No.: MIL05-043

CS06- Conducted Susceptibility, Spikes on Power Leads

Test EquipmentEquipment Manufacturer Model # Serial # Asset # Cal Date Cal DueTransientPulse Generator

Solar 8282-1 881811 00366 CNR CNR

Oscilloscope HP 54615B US35420829 00697 8-29-03 8-29-055 Ohms Resistor Solar Type 7144-5.0 CKC#1 00141 CNR CNRCNR = Calibration not required.

Test ProcedureCalibration: The test Engineer connected the source’s output across a 5 ohm load and connectedan oscilloscope across the load. The output level was increased until 12Vp was displayed on theOscilloscope and the output level was recorded. Plots were captured to show the pulse time andamplitude.

Test: Test Engineer connected the output of the source to the 28VDC Line and 28VDC Returnwithin 5cm of the UUT. The Oscilloscope was also connected across the 28VDC Line and 28VDC Return. The source was powered on with the output set to calibration level and spikes wereinjected into the power line of the UUT. The test was performed for 5 minutes in positivepolarity and then for 5 minutes in negative polarity.

Page 126: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 126 of 161Report No.: MIL05-043

CS06 Pre-Calibration

CS06 Test Setup

Page 127: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 127 of 161Report No.: MIL05-043

CS06 Closeup

Page 128: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 128 of 161Report No.: MIL05-043

CS06 Rep Rate of 10pps

CS06 Pulse Amplitude and Pulse Duration

Page 129: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 129 of 161Report No.: MIL05-043

CS06 +12V Pulse onto DC Line (Parallel Injection Method)

CS06 -12V Pulse onto DC Line (Parallel Injection Method)

Page 130: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 130 of 161Report No.: MIL05-043

CS102 - Conducted Susceptibility, Power Leads, 10kHz to 10MHz

Test EquipmentEquipment Manufacturer Model # Serial # Asset # Cal Date Cal Due

Oscillator General Radio 1310-B 4004 01730 CNR CNRPower Amplifier Techron 7570 8059 054333 02546 7/6/05 7/6/07Oscilloscope HP 54615B US35420828 00697 8/31/03 8/31/07Coupling Transformer Solar 6220-1A None 481 CNR CNRRF Coupler Solar 7415-3 925134 00620 CNR CNR50 ohms Load Resistor Bird Electronics 8134 01453 25632 CNR CNRResistor NTE .5Ohm None None Verified before useSignal Generator Marconi 2022D 119229/016 00687 9/20/05 9/20/07AMP AR 150A100A 24830 00894A CNR CNRCurrent MeasurementProbe

FCC F-35 296 00731 5/4/05 5/4/07

CNR = Calibration not required.

Test Procedure10-150kHz Calibration: The Oscillator’s output was connected to input of the Techron DCamplifier. The amplifier’s output was connected to the primary side of the Audio IsolationTransformer. A .5 ohm resistor was connected across the secondary side of the Audio IsolationTransformer. The Oscillator was set to 10kHz and the amplitude was brought up until thespectrum analyzer showed voltage corresponding to the calibration limit. Then Test Engineerswept though the range of 10-150kHz and recorded the necessary output levels to obtain thepower limit.

10-150kHz Test: The Audio Isolation Transformer was connected in series with the DC powerline. A 10uF capacitor was connected across 28VDC Line and 28VDC Return. The Currentmeasurement probe was clamped over the 28VDC Line between the UUT and the AudioIsolation Transformer. The current measurement probe was connected to the SpectrumAnalyzer. The test Engineer set the frequency to 10kHz and increased the levels until therequired voltage or the power limit was reached and swept though the frequency range of 10-150kHz.

Page 131: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 131 of 161Report No.: MIL05-043

150kHz-10MHz Calibration: The Signal Generator’s output was connected to the input of theamplifier. The amplifier’s output was connected to a RF coupler, which had 50 ohms load acrossthe output. A current measurement probe was clamped around the lead going from the output ofthe RF coupler to the 50 ohms load. The Signal Generator was set to 150kHz and the amplitudewas brought up until the spectrum analyzer indicated the voltage corresponding to the calibrationlimit. The test Engineer swept though the range of 10 – 150kHz and recorded the necessaryoutput levels to obtain the power limit.

150kHz - 10MHz Test: The RF coupler’s output was connected to 28VDC power Line, 5cmfrom the UUT. The Current measurement probe was clamped over the 28VDC Line between theUUT and the RF coupler. The current measurement probe was connected to the SpectrumAnalyzer. The test Engineer set the frequency to 150kHz increasing the levels until the requiredvoltage on the Spectrum Analyzer was indicated or the power limit was reached. Then theentire frequency range of 150kHz - 10MHz was swept.

Page 132: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 132 of 161Report No.: MIL05-043

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration #1

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration

Page 133: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 133 of 161Report No.: MIL05-043

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Calibration Closeup

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Pre-Cal Test Equipment

Page 134: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 134 of 161Report No.: MIL05-043

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Test Setup

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Test Setup Closeup

Page 135: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 135 of 161Report No.: MIL05-043

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #2

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #3

Page 136: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 136 of 161Report No.: MIL05-043

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz #4

CS102 Conducted Susceptibility, Power Leads, 15kHz - 10MHz Closeup

Page 137: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 137 of 161Report No.: MIL05-043

CSCM- Conducted Susceptibility, Common Mode, 30Hz to 150MHz

Test EquipmentEquipment Manufacturer Model # Serial # Asset # Cal Date Cal DueAMP Techron 7570 12 054333 2546 4-7-03 4-7-05Coupling Transformer Solar 6220-1A None 481 CNR CNRRF Coupler Solar 7415-3 925134 00620 CNR CNROscillator General Radio 1310-B None 1703 CNR CNR50 ohms Load Resistor Bird Electronics 8134 01453 25632 CNR CNRResistor NTE .5Ohm None None Verified before useSignal Generator Marconi 2022D 119229/016 00687 9/20/05 9/20/07AMP AR 150A100A 18240 1211 CNR CNRCNR = Calibration not required.

Test Procedure 30Hz to 150kHz

10-150kHz Calibration: The Oscillator’s output was connected to primary side of the AudioIsolation Transformer. 0.5 ohm resistor was connected across the secondary side of the AudioIsolation Transformer. The Oscillator was set to 30kHz and the amplitude was brought up untilthe spectrum analyzer showed voltage corresponding to the calibration limit. Then TestEngineer swept though the range of 10 - 150kHz and recorded the necessary output levels toobtain the power limit.

10-150kHz Test: The Audio Isolation Transformer was connected in series with the DC powerline. 0.5 ohm resistor was added to the secondary of the audio isolation transformer to dampenthe impedance per David Nelson. A 10uF capacitor was connected across the 28VDC InputPower Line and 28VDC Return Line. The current measurement probe was clamped over the28VDC Power Line between the UUT and the Audio Isolation Transformer. The currentmeasurement probe was connected to the Spectrum Analyzer. The frequency was set to 10kHzand the levels were increased until the required voltage or the power limit was reached. Theentire frequency range of 10 - 150kHz. was swept.

Page 138: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 138 of 161Report No.: MIL05-043

Test Procedure 150kHz – 150MHz

.150kHz - 150MHz Calibration: The Signal Generator’s output was connected to the input ofan amplifier. The amplifier’s output was connected to RF coupler, which had a 50 ohm loadacross its output. The Oscilloscope was connected across the 50 ohm load measuring the voltageto obtain the 1 watt power limit. The Signal Generator was set to 150kHz and the amplitude wasbrought up until the Oscilloscope indicated the voltage necessary to obtain 1 watt. The testengineer swept though the frequency range of 150kHz - 150MHz recording the necessary outputlevels to obtain the power limit.

150kHz - 150MHz Test: The RF coupler’s output was connected to 28VDC Power Line, within5cm from the UUT. The Oscilloscope was connected from 28VDC Power Line to Groundbetween the UUT and the RF coupler. The frequency was set to 150kHz and the output levelwas increased until the power limit (400mVpp) was reached. The entire frequency range of150kHz - 150MHz was swept.

Page 139: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 139 of 161Report No.: MIL05-043

Conducted Susceptibility Common Mode .03 - 150kHz Pre-Cal

Conducted Susceptibility Common Mode, .03 - 150kHz Test Setup

Page 140: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 140 of 161Report No.: MIL05-043

Conducted Susceptibility Common Mode, .03 - 150kHz Closeup

Conducted Susceptibility Common Mode, 15 - 150MHz Pre-Cal

Page 141: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 141 of 161Report No.: MIL05-043

Conducted Susceptibility Common Mode, .15 - 150kHz Test Setup

Conducted Susceptibility Common Mode, .15 - 150MHz Closeup

Page 142: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 142 of 161Report No.: MIL05-043

RS101 - Radiated Susceptibility, Magnetic Field, 30Hz to 100kHz

Test EquipmentFunction Asset # S/N Cal Date Cal DueSA - E4446A 02668 US44300408 01/13/2005 01/13/2007Current Probe F-10 02142 37 04/23/2003 04/23/2005GR - Oscillator 01703 4004 - Cal Not Required 02/28/2005 02/28/2005Tx Magnetic Loop 02719 05019 08/16/2005 08/16/2007Magnetic Loop Sensor 02720 05020 08/16/2005 08/16/2007DC Amp - 7570 02546 8059 054333 07/06/2005 07/06/2007

Test ProcedureA calibration of the test setup was performed per the method specified in MIL-STD-461EParagraph 5.18.3.4.

The function generator was connected to the amplifier and the output of the amplifier wasconnected to the transmit loop. The transmit loop was placed 5cm from the front face of theUUT. The test engineer manually increased the frequency from 30Hz to 100KHz whilemaintaining the necessary current going into the Tx loop, which was kept 10dB higher than therequired current for the limit. Current was being monitored by the current probe clamped ontoone of the two leads that were going to the Tx loop. The current was being displayed on the SA.Testing was repeated on the back, right side, left side, parallel to cable and top faces of the UUT.

The functionality of the UUT was monitored throughout the testing.

Page 143: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 143 of 161Report No.: MIL05-043

RS101 Radiated Susceptibility, Magnetic Field Pre-Cal

RS101 Radiated Susceptibility, Magnetic Field, Pre-Cal Closeup

Page 144: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 144 of 161Report No.: MIL05-043

RS101 Radiated Susceptibility, Magnetic Field, Test Setup

RS101 Radiated Susceptibility, Magnetic Field, Front Side

Page 145: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 145 of 161Report No.: MIL05-043

RS101 Radiated Susceptibility, Magnetic Field, Back Side

RS101 Radiated Susceptibility, Magnetic Field, Right Side

Page 146: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 146 of 161Report No.: MIL05-043

RS101 Radiated Susceptibility, Magnetic Field, Left Side

RS101 Radiated Susceptibility, Magnetic Field, Top Side

Page 147: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 147 of 161Report No.: MIL05-043

RS101 Radiated Susceptibility, Magnetic Field, Cables

Page 148: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 148 of 161Report No.: MIL05-043

RS103 - Radiated Susceptibility, Electric Field, 10kHz to 18GHz

Test EquipmentEquipment Manufacturer Model # Serial # Asset # Cal Date Cal Due

Signal Generator Marconi 2022D 119229/016 00687 9/20/05 9/20/07Signal Generator HP 8673C 2447A00198 02547 8/9/04 8/9/06Function Generator BK Precision 4011 9902-0294 02237 9/2/05 9/2/07Amplifier AR 30W1000M7 18691 01209 CNR CNRAmp (1-4GHz) Ophir 5162F 1020 02691 CNR CNRAmp (4-8GHz) Hughes 1277H002F000 177 1461 CNR CNRAmp (8-12GHz) Hughes 1277H03F000 18 01463 CNR CNRAmp (12-18GHz) Hughes 8010H04F000 157 0992A CNR CNROscilloscope HP 54615B US35420829 00697 8/31/03 8/31/07Biconical Antenna EMCO 3104 2683 00732 4/11/05 4/11/07DRG Antenna A.H. Systems SAS-570 155 02525 6/10/05 6/10/07DRG Antenna EMCO 3115 9602-4660 02113 3/8/05 3/8/07Field Monitor AR FM 2000 18327 00951A 3/16/05 3/15/07Field Probe AR FP 2000 18676 01207 11/12/03 11/12/05Field Probe AR FP 2080 24792 00870 6/25/04 6/25/06

Test ProcedureRS103 Test Levels and polarities:30MHz to 18GHz – 1 V/M vertical and horizontal polarities.

The output of the signal generator was connected to the amplifier. The amplifier was connectedto the E/H Field antenna. The antenna was brought in and placed in front of the UUT in verticalpolarization. The field probe was placed next to the UUT 30cm above the ground plane.

RS103 Test Sweep:The field probe was located in front of the Tx antenna, 1kHz squarewave modulation wasapplied to the threat signal with a 40dB On/Off ratio and a sweep was performed. The fieldstrength values were recorded at each frequency in the sweep from 30MHz to 18GHz at 1V/mThe functionality of the UUT was monitored throughout the sweep.

Antenna Polarities:For all testing , two transmit antenna polarities were used, Vertical and Horizontal. The antennawas set to horizontal polarity and the test was performed. Then the antenna was set to verticalpolarity and the test was performed. There were 3 antennas used; 30-200MHz, 200-1000MHz,1-18GHz.

Page 149: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 149 of 161Report No.: MIL05-043

30 to 200MHz Testing:The bi-conical antenna was brought in and placed 1 meter from the UUT. The sweep wasperformed using a 1kHz squarewave modulation. The field probe was used to measure the fieldstrength. The UUT was monitored throughout the testing for any signs of degradation. Theantenna was rotated to the vertical polarization and the sweep was repeated.

200 to 1000MHz Testing:The DRG antenna was brought in and placed 1 meter away from the UUT. The sweep wasperformed using a 1kHz squarewave modulation. The field probe was used to measure the fieldstrength. The UUT was monitored throughout the testing for any signs of degradation. Theantenna was rotated to the vertical polarization and the sweep was repeated.

1 to 18GHz Testing:The DRG antenna was brought in and placed 1 meter from the UUT in horizontal polarization.The field probe was placed in front of the antenna. The sweep was performed using a 1kHzsquarewave modulation. The field probe was used to measure the field strength. The UUT wasmonitored throughout the testing for any signs of degradation. The antenna was rotated to thevertical polarization and the sweep was repeated.

Page 150: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 150 of 161Report No.: MIL05-043

Bicon Antenna, 30 - 200MHz Vertical Polarization Test Setup

Page 151: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 151 of 161Report No.: MIL05-043

Horn Antenna, 200 - 1000MHz Vertical Polarization Test Setup

Horn Antenna, 200 - 1000MHz Vertical Polarization Closeup

Page 152: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 152 of 161Report No.: MIL05-043

Horn Antenna, 1 - 18GHz Horizontal Polarization Test Setup

Page 153: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 153 of 161Report No.: MIL05-043

Page 154: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 154 of 161Report No.: MIL05-043

Page 155: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 155 of 161Report No.: MIL05-043

TEST LOG

Date Name Time Event10/19/2005 A. Brar 745 Preparing lab.

800 Waiting for customer. Out schedule page isn’t working atthis time, contacting William Brandle.

801 William mentions that it should be up in 15 minutes.815 Page isn’t up yet.900 David Nelson from SLAC arrives with support equipment.

We will continue with setup.905 UUT has not arrived yet.930 Schedule page is up. Generating test log.945 Test log is ready. Placing the 10uF caps in shielded box.1015 Feed through caps at in a shielded box.1054 Setup complete, unit is functioning properly. Placing foil on

back side of the chamber, where the cables are entering.1100 Resistance between the UUT and test table is

0.35milliohms and resistance between the test table andchamber wall is 0.1milliohms.

1110 Now I’m going over the test plan with David to see whichtest should be performed first.

1127 Setting up to perform RE102 pre-cal.1205 Christine and I are on the conference call with Steve Behm.

Fred (witness) has arrived.1240 Continuing with RE102 pre-cal.1335 Rod antenna pre-cal complete. While we are at it we will

run the path check at 200 and 1000MHz as well. I’mborrowing the sig gen from Christine at this time and itneeds to be returned soon.

1349 Path check completed at 10kHz, 15.005MHz, 30MHz,200MHz, and 1000MHz. Path checks are withintolerance. Setting up to test from .01-30MHz.

1400 Begin testing from .01-30MHz with Rod Antenna.RE102 .01-30MHz SEQ 1 Rod Antenna

1405 Complete. Pass. Adding EUT and Support Equipment to theemissions data sheet.

1430 Begin testing from 30-200MHz.RE102 30-200MHz SEQ 2 VertRE102 30-200MHz SEQ 3 Horiz

1445 Complete. Pass.

Page 156: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 156 of 161Report No.: MIL05-043

1450 Begin testing from 200-1000MHz.RE102 200-1000MHz SEQ 4 VertRE102 200-1000MHz SEQ 5 Horiz

1503 Complete. Pass.1504 Now setting up to perform path check at 18GHz. Due to the

notches in the limit, test equipment has to be moved insideof the chamber.

1620 Setup complete. Modified the limit around the notched toperform path check at 18GHz.

1643 Pre-cal isn’t coming in, I will change the pre-ampstomorrow and continue with pre-cal.

1645 Log off.10/20/05 A. Brar 800 Swapping pre-amp and transducers.

820 Begin path check sweep is 18GHz.835 Sweep complete. Path check is within tolerance. Setting up

to perform testing.855 Loaded proper test equipment list into the emissions data

sheets.856 Begin testing from 1-18GHz.

RE102 1-1.55GHz Seq 6 VertRE102 1.6-1.77GHz Seq 7 VertRE102 2.3-18GHz Seq 8 VertRE102 1.55-1.6GHz Seq 9 Vert1.55-1.6GHz: RBW 3KHz, VBW 9.1KHz, Sweep Time20s/sweep, 17 sweeps.

915 Failing seq 9. Troubleshooting at 1.583976GHz.1030 The emissions are coming from J7 connector. David would

like to continue with testing.1040 Continuing with testing.

RE102 1.77-2.3GHz Seq 10 Vert1.77-2.3GHz: RBW 10KHz, VBW 30KHz, Sweep Time1s/sweep, 53 sweeps.RE102 1-1.55GHz Seq 11 HorizRE102 1.6-1.77GHz Seq 12 HorizRE102 2.3-18GHz Seq 13 HorizRE102 1.77-2.3GHz Seq 14 HorizRE102 1.55-1.6GHz Seq 15 Horiz

1148 Unit passes in horizontal polarity in the range of 1-18GHz.1157 Begin engr run in vertical polarity.

RE102 1.55-1.6GHz Seq 16 Vert1205 Complete. Fail.

Break for Lunch.

Page 157: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 157 of 161Report No.: MIL05-043

1300 Back form lunch.1304 Begin scan, lowered the RBW to 1KHz from 1.55-1.6GHz.

RE102 1.55-1.6GHz Seq 17 Vert 1KHz RBWRE102 1.55-1.6GHz Seq 18 Vert 1KHz RBWRE102 1.55-1.6GHz Seq 19 Vert 1KHz RBW

1335 Seq 19 passes. Moving onto RE101.1340 Moving and setting up outside of the chamber for RE101

pre-cal.1410 Setup outside of the chamber. Realized that the magnetic

loop is out of cal. Requested it from Mariposa, they willship it today. I will continue with some of the CE testing fornow.

1415 Setting up for CECM.1445 David would like to leave CECM for last since we need to

cut into the wires. I will setup to run CE102 pre-cal.1520 CE102 pre-cal setup complete.1525 Begin pre-cals at 10KHz, 2MHz & 10MHz.1635 Complete, and it is within tolerance.1640 Begin testing to CE102.

CE102 SEQ 20 POSITIVE LEADCE102 SEQ 21 Return LEAD

1652 Complete. Unit passes.1655 Log off.

10/21/05 A. Brar 800 Renaming photos. Preparing previous data for report.815 Determining which test to perform next.820 CECM seems to make better sense at this time.830 Randy needs to be working with S. Goulet therefore I will

need to take over in chamber 3 and C. Kendall with takeover SLAC. At this time Chuck is explaining the testing toRobert S. Goulet’s customer is running late.

845 Begin testing to CECM onto DC Line & Return. Capturingeach plot with different time divisions displaying the noiseto be below the spec.

953 Complete. Unit is well within tolerance, Pass.958 Setting up to perform RE101 path check.1044 Begin RE101 Path Check.1015 The SA is showing the signal at 50KHz, but the plot or data

sheet show not signs of the signal existing. When the SAsweeps through the last range, we clearly see the 50KHzsignal on the SA, but now on the plot or data sheet.

1045 Submitting a support request.

Page 158: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 158 of 161Report No.: MIL05-043

1100 On the phone with Greg, trying to resolve this problem.1200 No luck with this SA. Noon technical meeting.1230 Meeting complete. Lunch.1245 Back from lunch.1300 Unable to arrange an analyzer which will perform testing

from 20Hz to 50kHz, there is one in Chamber 3 but it isbeing used by S. Goulet. The one that can be swapped withchamber 3’s has a broken knob. We will have to delay thistest for now, that was 2 hours down the drain. I let Gregknow that whenever he gets his hands on one of the PSAs,try running these sweeps with the new software.

1310 Randy calls and mentions that the SA was set to collect8000 pts and he changed it to 1000, this should resolve theproblem, I will try it again.

1320 Now it is working fine. Setting up to test from 1m testdistance, locating a fixture to hold the loop.

1355 Begin testing to RE101. The model number on theemissions data sheets was listed wrong so far, I correctedit now, it will be correct from now on.RE101 SEQ 22 BACK SIDE – CONNECTORSRE101 SEQ 23 LEFT SIDERE101 SEQ 24 FRONT SIDERE101 SEQ 25 RIGHT SIDERE101 SEQ 26 TOP SIDE

1422 Complete. Unit passes. Setting up to perform CS102 pre-cal from 10-150kHz.

1500 Begin CS102 10-150kHz pre cal into 0.5ohmresistor.

1530 Pre-cal complete. setting up to perform CS102 testing from10-150kHz.

1620 Begin testing DC Line to CS102 from 10-150kHz. There isa 0.5 ohm resistor added to the output of the couplingtransformer per David’s request.

1630 Complete. Pass.1645 Begin testing DC Return to CS102 from 10-150kHz. There

is a 0.5 ohm resistor added to the output of the couplingtransformer per David’s request.

1655 Complete. Pass.1700 Log off.

10/24/05 A. Brar 800 Setting up for CS102 .15-10MHz pre-cal.900 Setup complete. Begin pre-cal.

Page 159: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 159 of 161Report No.: MIL05-043

920 Pre-cal complete. Setting up to perform testing.930 Realized that the UUT’s cable isn’t cut long enough for us

to be able to tap into it 5cm from the UUT. David is makingit longer.

1013 Begin testing from .15 to 10MHz to CS102.1029 Complete. Pass.1035 Setting up and discussing CSCM.1050 We will start of with .15 to 150MHz range.1105 Begin CSCM pre-cal from .15-150MHz.1130 Pre cal complete.1150 Begin testing to CSCM from .15-150MHz.1219 Complete. Pass.1220 Lunch.1245 Back from lunch. Continuing with CSCM pre-cal for lower

frequency range.1330 Pre-cal procedure seems to be wrong, I will follow the limit

specified in MIL STD 461 E. Chuck isn’t’ available at thistime to discuss the procedure.

1345 CSCM .03-150kHz setup complete. Begin testing from .03-150kHz.

1405 Complete. Pass.1410 Setting up to perform CS02 pre-cal.1425 Begin CS02 pre-cal.1440 Pre-cal complete. Setting up to perform CS02 testing.1445 Chuck called regarding CSCM from .03-150kHz, and

mentioned that the pre cal is just to confirm that the wave issinusoidal at 30Hz when the amplitude is 19.9Vp-p.

1500 Begin testing to CS02. Testing at +/-12V parallel injectionmethod. 5 minutes at each polarity, applying 10pps.

1512 Complete. Pass.1520 Setting up to perform RS103.1542 Cleaned out the chamber for the low frequency antenna.1626 Begin testing to RS103 from 30-200MHz in Vertical. Using

1kHz 50% duty cycle PM. Dwell time is 3 seconds.1656 Test complete up to 200MHz. Unit passes.1700 Log off.

10/25/05 A. Brar 815 I was running late due to traffic.818 Begin testing to RS103 from 30-200MHz in Horizontal.

Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds.846 Complete. Pass.

Page 160: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 160 of 161Report No.: MIL05-043

855 Begin testing to RS103 from 200-1000MHz in Vertical.Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds.

918 Complete. Pass.920 Begin testing to RS103 from 200-1000MHz in Horizontal.

Using 1kHz 50% duty cycle PM. Dwell time is 3 seconds.945 Complete. Pass.950 Administrative work, catching up with equipment list and

so on.1025 Added test equipment list, needs to be updated as far as cal

dates. Now continuing with 1-18GHz RS103 setup.1045 HF Sig Gen isn’t available yet, Robert needs it for about an

hour. I requested the customer to take longer lunch and bythe time he gets back we will have the sig gen. Updatingequipment list.

1110 Equipment list updated.1300 Robert mentions that he should be done by 1330 with the

HF Sig Gen.1345 Robert is done with the equipment. I’m moving it over to

MIL Chamber and setting it up.1422 Begin testing to RS103 from 1-18GHz in Horizontal. Using

1kHz 50% duty cycle PM. Dwell time is 1 seconds.1618 Complete. Pass.1623 Begin testing to RS103 from 1-4GHz in Vertical. Using

1kHz 50% duty cycle PM. Dwell time is 1 seconds.1650 Complete. Pass.1655 David is shutting down the unit.1657 Completing work order back with today’s changes.1700 Log off.

10/26/05 A. Brar 800 Booting up equipment.810 Waiting for the UUT to be ready.819 Begin testing to RS103 from 4-18GHz in Vertical. Using

1kHz 50% duty cycle PM. Dwell time is 1 seconds.931 Complete. Pass. RS103 testing has been completed from

30MHz to 18GHz and the unit passes in this range at1V/m level. The TP stated start frequency to be 14kHz,but per David Nelson and according to previous testingwe ended up starting off at 30MHz.

935 Tearing down RS103 setup to start off with RS101 pre-cal.

Page 161: ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR · PDF file · 2005-11-11ELECTROMAGNETIC INTERFERENCE TEST REPORT FOR THE STANFORD LINEAR ... 7. LAT-SS-00778 – LAT Environmental Specification,

Page 161 of 161Report No.: MIL05-043

1030 Setup for RS101 pre-cal complete. Not calculating thenumbers.

1100 Begin RS101 pre-cal.1113 Pre-cal complete, the final result1145 Begin testing to RS101. Testing cables, back side, right

side, front side, left side and top side.1220 RS101 complete. Unit Passes.1225 All testing per the test procedure has been completed and

the unit has met all of the requirements per the procedure.1432 All data has been updated and it is ready to be uploaded.1435 Log off.